11080050-EXPIRED CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 7855 FESTIVAL DR ' CONTRACTOR:JUNE C AU PERMIT NO: 11080050
OWNER'S NAME: JUNE C AU 7855 FESTIVAL DR DATE ISSUED:01/31/2012
OWNER'S PHONE: 4086508229 CUPERTINO,CA 95014 PHONE NO:
0 LICENSED CONTRACTOR'S DECLARATION r r 1
• BUILDING PERMIT INFO: BLDG ELECT PLUMB
License Class Lie.#
MECH RESIDENTIAL COMMERCIAL
Contractor Date
I hereby affirm that I am licensed under the provisions of Chapter 9 JOB DESCRIPTION:SFDWL ADDITION OF 1,038 SQ FT(KITCHEN,FAMILY,
(commencing with Section 7000)of Division 3 of the Business&Professions GUEST,BATH AND LAUNDRY ROOM-REMODEL BATH(50),
Code and that my license is in full force and effect. KITCHEN(210),LIBRARY,DINING,HALL AND NOOK(569)
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's lm _
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued.
[have and will maintain-Worker's Compensation Insurance,as provided for by .lan u
Section 3700 of the Labor Code,for the performance of the work for which this
ts4y Valuation:$162000
permit is issued.
APPLICANT CERTIFICATION ill Ott 36214001.00 Occupancy Type:
I certify that I have read this application and state that the above information is
correct.I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save PERMIT EXPIRES IF WORK IS NOT STARTED
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR
granting of this permit. Additionally,the applicant understands and will comply 180 DAY/F f OM LAST CALLED INSPECTION.
with all non-point source regulations per the Cupertino Municipal Code,Section •
9.18.
--/1 ('
14 ed ii: FAiibDate:
Signature Date / 3/ 24? /
OWNER-BUILDER DECLARATION
/ RE-ROOFS:
'I hereby affirm that I am exempt from the Contractor's License Law for one of All roofs shall be inspected prior to any roofing material being installed.If a roof is
the following two reasons: installed without first obtaining an inspection,I agree to remove all new materials for
I,as owner of the property,or my employees with wages as their sate compensation, inspection.
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code) Signature of Applicant: Date:
[,as owner afire property,am exclusively contracting with licensed contractors to
construct the project(Sec.7044,Business&Professions Code).
ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
I hereby affirm under penalty of perjury one of the following three
declarations:
HAZARDOUS MATERIALS DISCLOSURE
I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the I have read tire hazardous materials requirements under Chapter 6.95 of the
performance of the work for which this permit is issued. California Health&Safety Code,Sections 25505,25533,and 25534. 1 will maintain
I have and will maintain Worker's Compensation Insurance,as provided for by compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health&
Section 3700 of the Labor Code;for the performance of the work for which this Safety Code,Section 25532(a)should I store or handle hazardous material.
Additionally,should I use equipment or devices which emit hazardous air
permit is issued, contaminants as defined by the Bay Area Air Quality Management District I will
[certify that in the performance of the work for which this permit is issued,I shall maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
not employ any person in any manner so as to become subject to the Worker's Health&Safety Code,Sections 25505,25533,and 25534.
Compensation laws of California. If,after making this certificate of exemption,I
Owner
become subject to the Worker's Compensation provisions of the Labor Code,I must tiortid agent:
i au 3 i ....,,i 2.....__
/ , I
forthwith comply with such provisions or this permit shalt be deemed revoked. ' , ' Date:
de
di.
CONSTRUCTION LENDING AGENCY
APPLICANT CERTIFICATION
[certify that I have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the perfortnance of Inork's
correct.I agree to comply with all city and county ordinances and state laws relating for which this permit is issued(Sec.3097,Civ C.)
to building construction,and hereby authorize representatives of this city to enter Lender's Name
upon the above mentioned property for inspection purposes.(We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, Lender's Address
costs,and expenses which may accrue against said City in consequence of the
granting of this permit. 'dditionally,the applicant understands and will comply
ARCHITECT'S DECLARATION
with all non-po'it sourci re:ulaticns per the Cupertino Municipal Code,Section
9.18.
i! \ ) / 3i l7d I understand my plans shall be used as public records.
'-Signature i _Date Licensed Professional
\_
CITY OF CUPERTINO
FEE ESTIMATOR-BUILDING DIVISION
ADDRESS:, 7855 festival dr. DATE: 08/05/2011 REVIEWED BY: bob s.
"014$2 APN: 3 to ,? /t f BP#: //O 605D "VALUATION: $162,000
f
*PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition
PRIMARY 2nd Unit? Ca Yes e No PENTAMATION
SFD or Du lex 1 R3SFDADD
USE: - P OTC? 0 Yes e No PERMIT TYPE:
WORK sfd add kitchen,family, quest, bath and laundry= 978 sq ft, remodel library,dining,hall and nook 829 sq
SCOPE ft. Re-roof=3296 squares.
OCCUPANCY TYPE: TYPE OF FIR AREA PC FEES PC FEE ID BP FEES BP FEE ID
CONSTR.
R-3(Custom) -1
11-8,111-B,IV,V-B 1,038 $2,438.81 1R3PLNCK $1,586.38 1R3INSP
114. , A 1
TOTALS: $1,586.38
1e `° t_ 1 vilk.1►
MECH,HOURLY " 0 Yes' 0 No PLUMB,"it4o Yes 0 No ELEC HOURLY 0 Yes e Yo
ti,-,h l',1,,,,ch,c- c,�,, s.) f ae(ii ifi'lI 1,1ff Peas/C
l
Y t;7.P 7s a'Ye h,,_,..}, .re.r fee.: t.c'L.Sf?h��>JI ,,.
Oth,,, i,'•.,,i '-,v; [,, €),;,.f-, ki,q,,i,.,,,' ri ,,,,,,,,,, ,,T,„ lay, n
0.r ..a 27,f gf;; h4.,, bh,p.J-''. i- .jai,. 1-ep
NOTE:These ees are based on the ,reliminar in ormation available and are onl an estimate. Contact the Dept or addn'1 in o.
FEE ITEMS (Fee Resolution 11-053 EJf 7/1/11) FEE QTY/FEE MISC ITEMS.
Plan Check Fee: $2,438.81 50 s.f. Remodel,Bath(<=300 sf)
Suppl.PC Fee: 0 Reg. 0 OT 10.0 1 hrs $0.00 $588.00 1REMRESBAT
PME Plan Check: $0.00 210 s.f. Remodel,Kitchen(<=300 sf)
Permit Fee:. $1,586.38 $588.001 IREMRESKIT
Suppl.Insp.Feer Reg. 0 OT 0.0 hrs $0.00 569 s.f. Remodel,Other
PME Unit Fee: $0.00 $457.0011REMRESOTH 1
PME Permit Fee: $0.00 3,296 s.f. Re-roof
f;'n, tru do 1O;vFl $462.00 1REROOFRES
Acoustical Fee: 0 Yes 0 No $0.00 0
Work Without Permit? 0 Yes e No $0.00
Planning Fee: PLLONGRNGR $134.94 Select a Non-Residential 0
11 Building or Structure 0
/"tly ., Dzg-i£t-1t inatifon.l'('// : A
Strong Motioni Fee: 1BSEISMICR $16.20 Select an Administrative Item
Bldg Stds Commission Fee: 1BCBSC $7.00
SUBTOTALS. $4,183.33 $2,095.00 . TOTAL FEE; $6,278.33
Revised: 07/04/2011
t - CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT'DEPARTMENT• BUILDING DIVISION
.s� ssr 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255
, B
(408)777-3228• FAX(408)777-3333 •building(a cupertino.orq
CUPERTINO i i E'°°
E NEW CONSTRUC I ION ADDITION ❑ ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT#
PROJECT ADDRESS�"ftl Fes4,,V L 1 • t 41, �# Z ( -` 00 (
OWNER NAME ,1� 41 .e��t��� At
` PHONE4o 8 66c
1 E ®ALL k rI t C. t w4,< /viV"4, CA
fri
STREET ADDRESS 7ifbr • . o . Ckpaer t«IIZ CITY, STATE,p TE,ZIP /ft`c c FAX
CONTACT NAME ��i `� , PHO E-MAIL
l n ab • 6os3 'vet r. t i,�TM r..w04
• STREET'ADDRESS. D CITY,STATE,ZIP FAX
�1�1 Ped J,Je.r. IAA ti 5"P"-re)a A. 1 c.iq �1567a (708*872 -1'i 40
❑OWNER 2iOWNER-BUILDER lift WNERAGENT 0 CONTRACTOR 0 CONTRACTOR AGENT 12 ARCH GT0VEY.INEER 0 DEVELOPER 0 TE ANT
CONTRACTOR NAME q) LICENSE NUMBER c?L CEt�iS I BUS.LIC it
COMPANY NAME E-MAIL
.....,,,,N<\AV FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
ARCH,ITF�g�ER NP.iVIE0 LICENSE NUMBERC 6557 BUS.LIC#
CO ((//�`JJ NAME . � E-MAIL FAX
� � U �t/C lNLCiKJ/0 it 4a Lt. yahoo .Gs.•.�, o .g 7 3 #837
s • EI'ADORES TATE,ZIP PHONE
i[t6 SHM40�,. t G.40 At* SAS lose , e4el ,C*1 Li cog-4173 0 les?
DE CRIPTTON OF WORK
%�Icx CTt OM To pis C(At1)6• ICCT4 t I% 1,01 601/041', Qfint gApF c Lieu/40t,Li J`7 3 fa
(4614.°64* Piriuth T. t'`"t'Lut,$31.411.41 NV*0 C. 1 H Mr(, i � sock x
1Ze..- Rf A 4A . = 12.q s. .
- EXISTING USE PROPOSED USE .CONS E #STO S -
r USE TYPE OCC. SQ.FT. VALUATION(S)
-.oa�-
_ f
AREA Q D AREA cif«7 iQ AREA NET AREA \ vg
�FpI 7 / / /G a Crei-'4
BATHROOM KITCHEN OTHER.
--CFD
�y j,: ! ( V`�""
REMODEL AREA REMODEL AREA {{��--++ REMODEL pgpFp�'gd[ !►.,w,y
PORCH AREA ECCK�AAR TOTA ECK//sPORCHAREA GARAG AR A:5❑DETACH
CO c4i. K 60 `ft F. "®_ ❑ATTACH
P DWELLING UNITS: IS A SECOND UNIT ❑YES SECOND STORY ❑YES
BEING ADDED? SNA----ADDITION? ®NO---
PRE-APPLICATION DYES IF _ 5,PROVIDE COPY OF IS THE BLDG AN ❑YES RECEIVED BY:. TOTAL V.A2,UATION:
PLANNING APPL# LANNING APPROVAL LETTER EICHLER HOME? ,E-Ate-°® " / /.2_
By my signature below,I certify to each of the following: I am die property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building co...traction. I au41.ri -representatives of Cupertino to enter the above-identifi-d prop-. for inspection purposes.
��� r/ �Q
Signature of Applicant/Agent: Alli //i7Date: i
SUPPLEMENTAL INFO' 0 ON •-s I D PLAN UIRCK TYPE I- ROUTING SLIP
New SI U or Multifamily dwellings: Apply for demolition permit for ❑ ovEx i1i>r-CovNTER G PLAN REVIEW
existing building(s). Demolition permit is required prior to issuance of building
permit for new building. �❑,, EXPRESS �GPLAN REVIEW
_Commercial Bldgs: Provide a completed Hazardous Materials Disclosure I ANnnxn wOILKS
form if any Hazardous Materials are being used as part of this project. ❑ LARGE Er-FIE DEPT
_Copy of Planning Approval Letter or Meeting with Planning prior to
submittal of Building Permit application. 0
MAJOR ❑ SNf1ARX SEWER DISTRICT
0 ENVIRONMENTAL HEALTH
BldgApp_2011.doc revised 06/21/11
C
Nri s O BER=C3U LDER DISCLOSURE FOR
**,/,-::::.
COMMUNITY DEVELOPMENT DEPARTMENT=BUILDING DIVISION
,-4;ts 10300 TORRE AVENUE°CUPERTINO, CA 95014-3255
.t?
L _1x_-
(408)777-3228- FAX (408)777-3333 =buildina af�cuoertino.orq
CU ERI O
•
Dear Property Owner(s):
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at:
SITE ADDRESS \ � fiPN y BPS �
7 5 es Lap- rI v-e //_6800-5-0.
OWNER NAMIE OWNER ADDRESS �� res V (�, 7`�
DESCRIPTION OF WORK: `1--ej1 t.rl1
.
We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of
your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We
will not issue a building permit until you have read, initialed your understanding of each provision, signed, and
returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless
you,the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
(DIRCTIONS:Please read and initial each statement below to signify you understand or verify this information.)
-. .'t. I understand a frequent practice of unlicensed ersons is to have the property owner obtain an "Owner-
Builder" building permit that erroneously imp les that the property owner is providing his or her own labor and material
personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by
an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not
provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my
insurance coverage for injuries to workers on my property.
-2. I understand building permits are not required to be signed by property owners unless they are responsible for
the construction and are not hiring a licensed Contractor to assume this responsibility.
3. I understand as an "Owner-Builder' I am the responsible party of record on the permit. I understand that I may
--*
protect myself from potential financial risk by hiring a licensed Confractor and having the permit filed in his or her
name instead of my own.
4. I understand Contractors are required by law to be licensed and bonded in California and to list their license
numbers on permits and contracts.
5. I.understand if I employ or otherwise engage any persons,other than California licensed Contractors, and the
total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be
considered an "employer" under state and federal law.
6. I understand if I am considered an "employer" under state and federal law, I must register with the state and
deral government, withhold payroll taxes, provide workers'compensation disability insurance, and contribute to
unemployment compensation for each"employee." I also understand my failure to abide by these laws may subject
me to serious financial risk.
b ---
7. I understand under California Contractors' State License Law, an Owner-Builder who builds single-family
residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by
licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work
' performed under contract with a licensed general building Contractor.
_8..1 understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for
any financial or personal injuries sustained by any subsequent owner(s)that result from any latent construction
defects in the workmanship or materials.
Oii'nerBuilderForn: 2010.doc revised 04/14/10
( 9. I understand I may obtain more information regarding my obligations as an "employer"from the Internal
`evenue Service, the United States Small Business Administration, the California Department of Benefit Payments,
and the California Division of Industrial Accidents. I also understand I may contact the California Contractors'State
License Board (CSLB) at 1-800-321-CSLB (2752)or www.cslb.ca.gov for more information about licensed
contractors.
10. I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I
the party legally and financially responsible for proposed construction activity at the site address listed above.
I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide
*11.
applicable laws and requirements that govern Owner-Builders as well as employers.
12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the
information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If
you contract with someone who does not have a license, the Contractors' State License Board may be unable to
assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed
Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or
employee of that individual or firm is injured while working on your property, you may be held liable for damages. If
you obtain a permit as Owner-Builder and wish to hire Contractors,you will be responsible for verifying whether or not
those Contractors are properly licensed and the status of their workers' compensation insurance coverage.
CONSTRUCTION LENDING AGENCY
(DIRECTIONS:Please complete the following construction lending agency information.)
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued
(Sec 3097 Civ.)
Lender Name: Lender Address: •
I Before a building permit can be issued, this form must be completed and signed by the property owner and
returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license,
form notarization, or other verification acc-.table tolthe city may be required to be presented when the per it is issued
to veri the .ropert owner's signature. , 1
Property Owner's Signature: A A, Date: irli=
la
(NOTE: The following Authorization Form is required to be completed by the property owner only when designating an
agent of the property owner to apply for a construction permit for the Owner-Builder).
AUTHORIZATION OF AGENT TO ACT OI PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby
authorize the following person(s)to act as my agent(s)to apply for, sign, and file the documents necessary to obtain an
Owner-Builder Permit for my project.
Scope of.Construction Project(or Description of Work):
Project Location or Address:
• Name of Authorized Agent: Tel No
Address of Authorized Agent:
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the
above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other
verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's
signature. •
Property Owner's Signature: Date:
•
Qw7.erBuilderForm 2010.doc revised 04/14/10
BUILDING ENERGY ANALYSIS REPORT 2 20
AUG ® 5 2011 SU. MTTAL
Au Addition13
7855 Festival Drive
Cupertino, CA 95014
Project Designer:
- TDH Design
19034 Bonnet Way
Saratoga, CA 95070
(408) 829-6083
Report Prepared by:
Timothy Carstairs
Carstairs Energy Calculations
P.O. Box 4736
San Luis Obispo, CA 93403
(805) 904-9048
Job Number:
11-0526
Date:
5/26/2011
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft,LLC—www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2011-05-26T14:39:57 ID:11-0526
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1R Certificate of Compliance 3
Form MF-1R Mandatory Measures Summary 9
EnergyPro 5.1 by EnergySoft Job Number: ID:11-0526 User Number:6249
PERFORMANCE CERTIFICATE: Residential (Part 1 of 5) CF-1 R
Project Name Building Type ® Single Family 0 Addition Alone Date
Au Addition ❑ Multi Family 0 Existing+Addition/Alteration 5/26/2011
Project Address California Energy Climate Zone Total Cond. Floor Area Addition #of Stories
7855 Festival Drive Cupertino CA Climate Zone 04 2,779 978 1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ® No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft2) Features (see Part 2 of 5) Status
Floor Wood Framed w/Crawl Space None 1,801 Existing
Wall Wood Framed None 1,158 Existing
Door Opaque Door None 51 New
- Roof Wood Framed Attic R-11 1,792 Existing
Wall Wood Framed R-13 907 New
- Roof Wood Framed Attic R-30 958 New
Slab Unheated Slab-on-Grade None 978 Perim=124' New
FENESTRATION U- Exterior
Orientation Area(ft2) Factor SHGC Overhang Sidefins Shades Status
Front(S) 96.0 0.550 0.67 none none Bug Screen New
Rear(N) 32.0 0.710 0.73 none none Bug Screen Existing
Left(W) 36.0 0.710 0.73 none none Bug Screen Existing
Left(VV) 15.0 0.550 0.67 none none Bug Screen New
Skylight 9.5 0.550 0.67 none none None New
Right(E) 13.5 0.550 0.67 none none Bug Screen New
Right(E) 18.0 0.530 0.67 none none Bug Screen New
Rear(N) 67.0 0.550 0.67 none none Bug Screen New
Skylight 20.0 0.550 0.67 none none None New
Rear(NE) 129.3 0.550 0.67 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78%AFUE Split Air Conditioner 13.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Coolin Duct Location R-Value Status
HVAC System Ducted Ducted Attic, Ceiling Ins,vented 4.2 Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number.:6249 RunCode:2011-05-26T14:39:57 ID:11-0526 Page 3 of 11
1 L
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R
Project Name Building Type ®Single Family 0 Addition Alone Date
Au Addition. 0 Multi Family 0 Existing+Addition/Alteration 5/26/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist.These items require special written
justification and documentation,and special verification to be used with the performance approach.The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
' EnergyPro 5.1 by EnergySof User Number:6249 RunCode:2011-05-26T14:39:57 ID:11-0526 Page 4 of 11
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1R
Project Name Building Type .m Single Family 0 Addition Alone Date
Au Addition 0 Multi Family l 1 Existing+Addition/Alteration 5/26/2011
ANNUAL ENERGY USE.SUMMARY
Standard Proposed Margin
TDV (kBtu/ft2-yr)
Space Heating 56.05 50.65 5.39
Space Cooling 20.86 24.52 -3.66
Fans 11.81 12.21 -0.39
Domestic,Hot Water 15.58 15.58 0.00
Pumps 0.00 0.00 0.00
Totals 104.30 10296 1.33
Percent Better Than Standard: 1.3%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S)180 deg Ext_Walls/Roof Wall Area Area
Number of Dwelling Units: too (S) 629 96
Fuel Available at Site: Natural Gas (149 524 51
Raised Floor Area: 1,801 (N) 745 228
Slab on Grade Area: 978 (E7 625 32
Average Ceiling Height: 8.7 Roof 2,779 30
Fenestration Average U-Factor: 0.58 TOTAL: 436
Average SHGC: 0.68 Fenestration/CFA Ratio: 15.7
REMARKS
STATEMENT OF COMPLIANCEF..�---,
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the �`TIFIED �ERGYAN ANALYST
p Y 9 CERTIFIED ENERGY ANALYST
Efficiency Standards of the California Code of Regulations. f Timothy f--t---
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Carstairs Energy Calculations 5126 411
Address P.O.Box 4736 Name Timothy Carstairs /.:, `�
City/State/Zip San Luis Obispo,CA 93403 Phone (805)904-9048 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets,with the specifications,and
with any other calculations submitted with this permit application,and recognizes that compliance using duct design,
duct sealing,verification of refrigerant charge,insulation installation quality,and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company TDH Design
Address 19034 Bonnet Way Name to
• City/State/Zip Saratoga,CA 95070 Phone(408)829-6083 Signed License# Date
- EneravPro 51 by EneraySoft User Number.6249 RunCodfe:2011-05-26T14:39:57 ID:11-0526 Page 5 of 11
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R
Project Name Building Type 0 Single Family 0 Addition Alone Date
Au Addition 0 Multi Family ❑ Existing+Addition/Alteration 5/26/2011
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Floor 1,801 0.097 None 0 180 Existing 4.4.1-Al Existing 1st Floor
Wall 217 0.356 None 180 90 Existing 4.3.1-Al Existing 1st Floor
Door 17 0.500 None 180 90 New 4.5.1-A4 Existing 1st Floor
Wall 360 0.356 None 90 90 Existing 4.3.1-Al Existing 1st Floor
Wall 168 0.356 None 0 90 Existing 4.3.1-Al Existing 1st Floor
Wall 413 0.356 None 270 90 Existing 4.3.1-Al Existing 1st Floor
Roof 1,792 0.079 R-11 0 18 Existing 4.2.1-A2 Existing 1st Floor
Wall 92 0.356 None 180 90 Removeo 4.3.1Al Existing 1st Floor
Wall 104 0.356 None 1 90 90 Remove°4.3.1-Al Existing 1st Floor
Wall 91 0.356 None 0 90 Removeo4.3.1-A1 Existing 1st Floor
Wall 265 0.102 R-13 180 90 New 4.3.1-A3 1st Floor Addition
Door 34 0.500 None 180 90 New 4.5.1-A4 1st Floor Addition
Wall 234 0.102 R-13 90 90 New 4.3.1-A3 1st Floor Addition
Wall 208 0.102 R-13 0 90 New 4.3.1-A3 1st Floor Addition
- Wall 60 0.102 R-13 270 90 New 4.3.1-A3 1st Floor Addition
- Roof 958 0.031 R-30 180 18 New 4.2.1-A20 1st Floor Addition
FENESTRATION SURFACE DETAILS
_ ID Type Area U-Factor' SHGC2 Azm Status Glazing Type Location/Comments
1 Window 40.0 0.710 Default 0.73 Default 180 Removed Double Metal Clear Existing 1st Floor
2 Window 30.0 0.550 Default 0.67 Default 180 New Double Non Metal Clear Existing 1st Floor
3 Window 6.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear Existing 1st Floor
4 Window 32.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing 1st Floor
5 Window 36.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing 1st Floor
_ 6 Window 15.0 0.550 Default 0.67 Default 270 New Double Non Metal Clear Existing 1st Floor
7 Skylight 16.0 0.550 Default 0.67 Default 0 Removed Double Non Metal Clear Existing 1st Floor
8 Skylight 9.5 0.550 Default 0.67 Default 0 New Double Non Metal Clear Existing 1st Floor
_ 9 Window 12.0 0.710 Default 0.73 Default 180 Removed Double Metal Clear Existing 1st Floor
10 Window 53.3 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing 1st Floor
11 Window 66.0 0.550 Default 0.67 Default 180 New Double Non Metal Clear 1st Floor Addition
12 Window 13.5 0.550 Default 0.67 Default 90 New Double Non Metal Clear 1st Floor Addition
13 Window 18.0 0.530 Default 0.67 Default_ 90 New French Door 1st Floor Addition
14 Window 67.0 0.550 Default 0.67 Default 0 New Double Non Metal Clear 1st Floor Addition
15 Skylight 20.0 0.550 Default 0.67 Default 180 New Double Non Metal Clear 1st Floor Addition
16 Window 129.3 0.550 Default 0.67 Default 45 New Double Non Metal Clear 1st Floor Addition
(1) U-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value
(2) SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value
EXTERIOR SHADING DETAILS
Window Overhang Left Fin Right Fin
ID Exterior Shade Type SHGC Hgt Wd Len Hgt LExt RExt Dist Len_ Hgt Dist Len Hgt
1 Bug Screen 0.76
2 Bug Screen 0.76
3 Bug Screen 0.76
4 Bug Screen 0.76
5 Bug Screen 0.76
6 Bug Screen 0.76
7 None 1.00 '
8 None 1.00
9 Bug Screen 0.76
10 Bug Screen 0.76
11 Bug Screen 0.76
12 Bug Screen 0.76
13 Bug Screen 0.76
14 Bug Screen 0.76
15 None 1.00
• 16 Bug Screen 0.76
' EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2011-05-26T14:39:57 ID:11-0526 Page 6 of 11
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1R
Project Name Building Type 0 Single Family ❑Addition Alone Date
Au Addition 0 Multi Family 0 Existing+Addition/Alteration 5/26/2011
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab 978 0.730 None 0 180 New 4.4.7-A1 1st Floor Addition
Wall 141 0.102 R-13 45 90 New 4.3.1-A3 1st Floor Addition
FENESTRATION SURFACE DETAILS
ID Type Area U-Factor' SHGC2 Azm Status Glazing Type Location/Comments
(1) U-Factor Type: 116-A=Default Table from Standards, NFRC=Labeled Value
(2) SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value
EXTERIOR SHADING DETAILS
Window Overhang Left Fin Right Fin
ID Exterior Shade Type SHGC Hgt Wd Len Hgt LExt RExt Dist Len Hgt Dist Len Hgt
EnergyPro 5.1 by EnergySoft User Number.6249 RunCode:2011-05-26T14:39:57 ID:11-0526 Page 7 of 11
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R
Project Name Building Type ❑ Single Family 0 Addition Alone Date
Au Addition 0 Multi Family ❑ Existing+Addition/Alteration 5/26/2011
BUILDING ZONE INFORMATION
Floor Area(ft4)
System Name Zone Name New Existing Altered Removed Volume Year Built
HVAC System Existing 1st Floor 1,801 14,408 1977
1st Floor Addition 978 9,780
Totals 978 1,801 0 0
HVAC SYSTEMS
System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System 1 Central Furnace 78%AFUE Split Air Conditioner 13.0 SEER Setback New
HVAC DISTRIBUTION
Duct Ducts
System Name Heating Cooling Duct Location R-Value Tested? Status
HVAC System Ducted Ducted Attic, Ceiling Ins,vented 4.2 0 Existing
0
0
WATER HEATING SYSTEMS
Ext.
Rated Tank Energy Standby Tank
Input Cap. Factor Loss or Insul. R-
System Name Qty. Type Distribution (Btuh) (gal) or RE Pilot Value Status
Standard Gas 50 gal or Le. 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing
MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING
Hot Water Piping Length
(ft) --
- c-aa Pipe Pipe Insul.
Control Qty. HP Plenum Outside Buried a — System Name Length Diameter Thick.
0
0
0
0
0
EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2011-05-26T14:39:57 ID:11-0526 Page 8 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3) MF-1 R
Project Name Date
Au Addition 5/26/2011
NOTE:Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1R,CF-1R-ADD,or CF-
1 R-ALT Form)shall supersede the items marked with an asterisk(*) below.This Mandatory Measures Summary shall be incorporated
into the permit documents,and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
§116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products(except field-fabricated windows) have a label listing the certified U-Factor,certified Solar Heat Gain
Coefficient(SHGC),and infiltration that meets the requirements of§10-111(a).
§117: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed.
§118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form.
9118(i):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(i)when the
installation of a Cool Roof is specified on the CF-1R Form.
*§150(a):Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
_- *§150(c):Minimum R-13 insulation in wood-frame wall or equivalent U-factor.
*§150(d):Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor.
§150(f):Air retarding wrap is tested, labeled,and installed according to ASTM E1677-95(2000)when specified on the CF-1R Form.
§150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance
rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150(e)1A:Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is
equipped with a with a readily accessible, operable,and tight-fitting damper and or a combustion-air control device.
§150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the
outside of the building,are prohibited.
Space Conditioning,Water Heating and Plumbing System Measures:
§110-§113:HVAC equipment,water heaters, showerheads,faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release
valve, backflow prevention,pump isolation valve, and recirculation loop connection requirements of§113(c)5.
§115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and
spa heaters.
§150(h):Heating and/or cooling loads are calculated in accordance with ASHRAE,SMACNA or ACCA.
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2:Cooling system piping(suction,chilled water,or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards Table
123-A.
§150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture,equipment maintenance,and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150(j)4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2011-05-26T14:39:57 ID:11-0526 Page 9 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3) MF-1R
Project Name Date
Au Addition 5/26/2011
§150(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections
601,602,603,604, 605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the
applicable requirements of UL 181, UL 181A,or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings greater than 1/4 inch,the combination of mastic and either mesh or tape shall be used
§150(m)1:Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed
sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
§150(m)7:Exhaust fan systems have back draft or automatic dampers.
§150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight,moisture,equipment maintenance,and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
- radiation that can cause degradation of the material.
§150(m)10: Flexible ducts cannot have,porous inner cores.
§150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
- Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency
Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and
shall not use electric resistance heating or a pilot light.
§114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction
and return lines,or built-up connections for future solar heating.
§114(b)2:Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
§150(p): Residential pool systems or equipment meet the pump sizing,flow rate,piping,filters,and valve requirements of§150(p).
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire as specified by§150(k)2.
§150(k)3:The wattage of permanently installed luminaires shall be determined as specified by§130(d).
§150(k)4:Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5:Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d),and shall not contain a
medium screw-base socket.
§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens,shall meet the applicable requirements of§150(k).
§150(k)7:All switching devices and controls shallmeet the requirements of§150(k)7.
§150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor,dimmer,energy management system (EMCS),or a multi-scene programmable control system;and all permanently installed
luminaries in garages, laundry rooms,closets greater than 70 square feet,and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2011-05-26714:39:57 ID:11-0526 Page 10 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3) MF--I R
Project Name Date
Au Addition 5/26/2011
§150(k)10:Permanently installed luminaires in bathrooms,attached and detached garages,laundry rooms,closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of§119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)11:Permanently installed luminaires located in rooms or areas other than in kitchens,bathrooms,garages, laundry rooms,
closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119, or by a manual-
on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2:Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with§150(k)11.
§150(k)12:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters
Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13:Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units,entrances,balconies,and porches,which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor
luminaires used to comply with Exception1 to§150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to§130(d).
§150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134,and 146.
§150(k)16:Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensor(s)certified to comply with the applicable requirements of§119.
•
f
EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2011-05-26T14:39:57 ID:11-0526 Page 11 of 11