Loading...
15110003CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10513 PERALTA CT CONTRACTOR: THE SOLAR COMPANY, PERMIT NO: 15110003 INC OWNER'S NAME: SUNDARRAJ A P AND HEMA TRUSTEE 20861 WILBEAM AVE STE 1 DATE ISSUED: 11(02/2015 OWNER'S PHONE: 6502838510 CASTRO VALLEY, CA 94546 PHONE NO: (510) 214 -9005 El LIC SED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL q� 'ftp Install (N) rooftop mounted solar PV - 18 Panels (6.5 KW) License Class Lic. # S- Contractor S � r,0,1 F'"Wq Date 1 F / 2.- t 5; I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $18000 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APN Number: 34260017.00 Occupancy Type: APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter WITHIN 180 DAYS OF PERMIT ISSUANCE OR upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this 11P rmit. Additionally, the applicant understands and will comply rr Issued by: d Date: _ with all non- int source regulat ns per the Cupertino Municipal Code, Section 9.18. /1j Signatur Date MA- - I r RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed.. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. El OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (See.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self - insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation; as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by t ay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance wit he upertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this the Health & Safety Code, ction 25505, 2 3, and 25534. r- Owner or authorized a ' nt: Date: [ /�, permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION [a COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISI ON 10300 TORRE AVENUE - CUPERTINO, GA 95014 -3255 CtJPERT (408) 777 -3228 ,. FAX (408) 777 -3333 i- buildup "Scuperlir€a orb€ > 10513 PERALTA CT. 1 -'' 342 -60 -017 ` HEMA SUNDARRAJ 650 -283 -8510 € - . ".��tsundarraj @sunpreme.co same CA 95014 as above CON ACT Jv, Andre Laines PgoNE 209 - 418 -8947 E -MIL TSCdesign @TheSolarCo.com ""IDDRII" 20861 Wilbeam Avenue CITY STAB Castro Valley, CA 94546 '877-527-7339 ® OWNER. Cl OAVMRE UEEDIE. ❑ atM1311AGENT ❑ MNTYzarrnu r rrn.rroarmna .—.-s• r-r. -- r't .b.,r.,;..».. r, n —_... CtIAiTRACT41�. t'J,#MC "- The Solar Company, Inc TL tcE;.tsE �rtrNME" 596651 t t rsJS T PrE B C46 BUS. LiL'4 31418 . CU SPANY NiO iE The Solar Company, Inc. E.A•L43i:: Andre TheSolarCo.com FAX 877- 527 -7339 STttEgT Ai3IlRESS 0 61 Wilbeam Aven CITY, 4TAYP, ZL�> . ,.. t+%fQiJE 877 -607 -6527 x 710 AR.CHITECTIENGPV"M NAME LICENSE NUgMER BUS, LIC 0 COMPAKY N.AbIE E -MAIL FAX T .4Z;JtlESS CITY, STATE, ZIP PHONE USE or- ❑ SFDorDuplex 0. Nfulit- Family PROJECT N WILDL 1;ND - PROJECT EN STRucruRE, Cl Commercial URBAN INTERFACE AREA ❑ Yes jg No FLooD ZONE Yes 0 No D(S©LARPANELS ❑ II .EGTRiC'VEiHCLECK-kRGINGSTA SOLAR WATER i EATUM ❑ oTriM- : FOR SOLAR P-4 -NEVI. N[:Z PF ?,ANELSi[J' & � � KILOWATTS iCONWERCiAL 0141-1j" DESCRIPTION OF WORK Install 6.5 kw grid tied solar electric system (PV) roof mount By my sipature below, I eerti� to eac ofthe following: I arc the property owner or authorized went to iict on ttte groperty esker's Mialf. I have read. this application and the information I e pr vided is correct. I have t r� Qr Work and verift it is accurate, I agree to comply with all applicable local ordinances and stare laws relati a €o lava' ing construction. I au err �entatives upertinti to eater the at ove -ifde /tit' Fejd rrroperty foz inspection pru,-pOses. / f L INFORMATION REQUIRED €?FIFtC USE ONLY #.... . ,.. 4E. $'1'ANDAAIM PVripp 201 Ldoc revised 193116111 5 Fill E3 CITY OF CUPERTINO 1511 OW3, FEE ESTIMATOR — BUILDING DIVISION ADDRESS: 10513 Peralta Ct. DATE: 11/0212015 REVIEWED BY: PAUL APN: 342 60 017 BP#: *VALUATION: 1$18,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex PENTAMATION USE: PERMIT TYPE: SOLAR-RES WORK I Install (N) rooftop mounted solar PV - 18 Panels (6.5 K" SCOPE I I 001wr5dc- ::.Lisp. IInsin. Fee: 0012 r.P1UJi7b.1'nSp. I'lumb- lnsp� Fee: 01,her Elee, 1"'isp. Elee. Imp. 11'ce: NOTE. This estimate does not include fees due to other Departments (i.e. Planning, Public works, rare, )oan'1arY, ewerutsrrtct, acnuut -4 ly. --I ------- ­—M-161. ­I — —lit "" avamlyfo i -t tho nont for addnl info. FEE ITEMS (Fee Resolution 1.1-053 Eff 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System $236.001 ipHoTovREs Photovoltaic System A Suppl. PC Fee: (j) Reg. 0 OT ('04. plan Check hrs $0.00 PME Plan Check: $0.00 Phmib. Permit Fee: 2 X ec, Suppl. Insp. Fee: 0 Reg. 0 OT f7o.701 hrs E le. c. Man Clw,"k PME Unit Fee: $0.00 PME Permit Fee: AIech Ilermil FeC: C.onslrucllon Tax., F F"IM7b, Pcrmit .4(hnfnisirafive 1 -'ec: ]Iennit Fee: I 001wr5dc- ::.Lisp. IInsin. Fee: 0012 r.P1UJi7b.1'nSp. I'lumb- lnsp� Fee: 01,her Elee, 1"'isp. Elee. Imp. 11'ce: NOTE. This estimate does not include fees due to other Departments (i.e. Planning, Public works, rare, )oan'1arY, ewerutsrrtct, acnuut -4 ly. --I ------- ­—M-161. ­I — —lit "" avamlyfo i -t tho nont for addnl info. FEE ITEMS (Fee Resolution 1.1-053 Eff 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System $236.001 ipHoTovREs Photovoltaic System A Suppl. PC Fee: (j) Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee: 0 Reg. 0 OT f7o.701 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 C.onslrucllon Tax., F .4(hnfnisirafive 1 -'ec: 0 Work Without Permit? 0 Yes No $0.00 Advanced Planning Fee. $0.00 Select a Non-Residential E) Building or Structure 0 'A Trcxvel Strong Motion Fee: IBSEISMICR $2.34 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 -To" k. Sut TAILS. $3.34 $236.00 v $ 239.34 Nevisea: w/wizu-io CUPERTINO Owner Name � U Address MAIJAM91-4 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 t F (408) 777 -3333 - buiIding(a)cuDeq'! -3228 ; gggM � .... I.. Permit No. 1. Is your real property a registered historical site? El es Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plu Bing, installation of water-conserving plumbing fixtures is not technically feasible? Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. No Go to Question 3, 3. Is water service permanently disconnected for your building? 4es Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. o Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. e�, Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. Please check ONE of the following: My property is a single family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 1, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 110 1.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water-conserving plumbing fixtures comply with the requirements as indicated in the table on the following nape. Owner or Owner Agent's Signature: Date: Upon completing and signing this Certificate, please return it to the Building Division in order to final your but tding ' pen-nit. SB407 2015.doc revised 08126115 I 50076-M A *#MfT11ftIT'T DEVELOPITI�--aT-DEP-AR7CT-1--BIIILDIF"%'G 13174`%Cyll�' 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 -.buHdinq��cqpertino.orq Q) PERAIIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN _SJQW,'�R AND RETIMED TO THE BUILDING DIVISION This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section 8314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel- burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units,, alarms are ' permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section 8314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. and agree to with the terms and conditions of this statement •Q - IN 692"VrAr Re-= Sicinature .... s 1 121 ............. . ....... a.. Contractor Na e: 9-. Ike ;0 ✓ 5-t.... Date: Smoke and COfonn. doe revised 03118114 Photovoltaic Solar Electric System for SUNDARRAJ RESIDENCE 10513 PERALTA CT CUPERTINO, CA 95014 Project Address: 10513 PERALTA CT CUPERTINO, CA 95014 APN#: 342-60-017 Bldg. Owner: Hema Sundarraj (650) 283-8510 hsundarraj@sunpreme.com Contractor: I r*16=191011-T, 1911� OFFICE COPY The Solar Company, Inc. CSL# 596651, B, C46 COMMUMTY OWEEELOPNIENT E)EEPAR n1AENT Mark Danenhower, President SUILDNG DIVOON - GUF-ERTINO 1550 Carbondale Rd., Ione, CA 9564j*jj"-PR%[ Mailing Address: TH9 prof of pfarts and speoffications P,,!,USTbe!, st, eAtfis 20861 Wilbeam Avenue Ste—l5"" - ' , Un, utrumlom Lnn!a%63 fl, to m Castro Valley, CA 94546- aike aily 'r a1mr �Orls oil sa;me, or to dow"ac) �9Z' "" Fax: (877) 527-7339 thoro frog , w"Ithout approval fra n§ the Buildh,,g Official. Direct: (510) 214-9005 Tba, stamping of this planand areffbatlons 814,18tU- t,�OT Workers Comp. to held to peinrmt or t() beam app ass ,ad of t1he v olaldcn - 11 Q Ooa or Sta Law. Carrier: California Ins. C�'Phypro�,Iqiqn f C rd) nan te Policy: #46-001546-02-01, 0 8*1 BY PERMIT NO. Project Desc: Install a new 6.5kW PG&E Grid Tied Solar Electric System, Roof Mount Solar Specs: SIZE: PV MODULE TYPE: # OF PV MODULES: PV ARRAY AREA: INVERTER (S) : TYPE OF MOUNT: LOCATION: 6480(PUC) SunPreme SNPM-GxB-360 18 376 Square Feet SOLAREDGE SE760OA-US Roof Mount See Spec. il WARNING! ELECTRIC SHOCK,#4RD 510 NOT TOUCH TERMINALS! ♦ X♦ X VOLTS D.C. TEKVOLTAGE XXX VOLTS D. C CURRENT XX AMPS 5753101"no 11r, pp, • Smoke Detectors and Carbon Monoxide Alarms shall be installed in accordance with CRC R314 and CRC R315 • Along with any other applicable local and state laws and regulations CUPERTINO St.,fflding Department 2 ` N0V 0 $-1 Z( 1 X: REVIEWED FOR CODE CoMPUANCE Reviewed By: Twwvb� RFA_�bl Sheet Sheet Number List Table Sheet Title 1 CODE NAME: CODE TYPE: California Fire Code 2013 Edition California Building Code 2013 Edition California Mechanical Code 2013 Edition California Plumbing Code 2013 Edition California Electric Code 2013 Edition California Residential Code 12013 Edition • Smoke Detectors and Carbon Monoxide Alarms shall be installed in accordance with CRC R314 and CRC R315 • Along with any other applicable local and state laws and regulations CUPERTINO St.,fflding Department 2 ` N0V 0 $-1 Z( 1 X: REVIEWED FOR CODE CoMPUANCE Reviewed By: Twwvb� RFA_�bl Sheet Sheet Number List Table Sheet Title 1 Z SUNDARRAJ Title Page Index Warning Labels 2 SUNDARRAJ PLOT PLAN 3 Cl! SUNDARRAJ SINGLE LINE DRAWING 4 Spec Sheet SunModo L-Foot 5 CD Spec Sheet Module SunPreme GxB-XXX 6 Spec Sheet Inverter Solar Edge SE3000 - SE1140OA-US 7 Spec Sheet Solar Edge P300 - P405 Power Optimizer 8 Spec Sheet Solar Edge Power Optimizer Grounding 9 F4 Z C� Labels Spec Sheet Office (209) 676-3497 Fax (510) 888-9299 TheSolarCo.com r General Notes A %No-1 Revision/issue I Dat do" ------------------ /Date: October 27, 2015 Scale: Drawn By: Darwin Ruiz Office (209) 676-3497 Fax 510 ) 888-9299 TSCdesign@TheSolarCo.com Title: I SUNDARRAJ Title Page Index Warning Labels �S �he e t : �l L Z Cl! CD E-4 L() < F4 Z C� El O In la, (1,4 Hu(n %No-1 Revision/issue I Dat do" ------------------ /Date: October 27, 2015 Scale: Drawn By: Darwin Ruiz Office (209) 676-3497 Fax 510 ) 888-9299 TSCdesign@TheSolarCo.com Title: I SUNDARRAJ Title Page Index Warning Labels �S �he e t : �l L T N c .ct a +3 U 4 M zs v a z a w H 0 a a h a a v R 0 0 H N D it N cn t U r Solar PV Array 31' — 411 Composition Roofing Rafter & Sheathing 3 -212" SS Lag Bolt (Typ) alant in pre- drilled hole} System and Flashing L -FOOT MOUNTING SYSTEM DETAI NO SCALE • 18 SunPreme SNPM —GxB -360 • 1 SOLAREDGE SE760OA —US • 5886 WATTS • COMPOSITION SHINGLE • 2 — STORY • 160 PITCH 133 0,218 0,3080 AZIMUTH • 400 AMP MAIN PANEL BUSBAR • 200 AMP MAIN BREAKER • CENTERFED MAIN PANEL: NO JJ d AV General Notes 1 CU ERTINO ulddi c, Department N 2 20,15 Ou REVIEWED F0 COMPLIANCE JJ .t! • • - PV SYSTEM P.O.C.WILL BE IN THE MAIN PANELBOARD POLE BREAKER LEGEND KEY: MSP MAIN SERVICE PANEL INV INVERTER (JB JUNCTION BOX FD FRONT DOOR INTERNAL MMOMMUMN DC EXTERNAL CONDUIT • UMTREMOM AC EXTERNAL CONDUIT 3' FIRE CODE SETBACK r1 H US r-i 0 Sheet: 2 I%%- , P LO CJ � C^` F4 Z-+ o p H i � W P U-) Ra N Sheet: 2 I%%- , tes: 1. inverters ganged together. 2. No utility required AC Disconnect as per PG&E code. 3. All Work to meet NEC 2011 or 2013 CEC. 4. All values subject to be rounded to next easily available trade size. 5. The lowest recorded temperature is -12 °C. 6. Data provided by www.solarabcs.org. 7. integrated DC Disconnect on SolarEdge, SMA & SunPower inverters, therefore it is impossible to have Line and Load hot if disconnect is open. 8. Disconnect is wired so that utility feeds the protected side of the disconnect. 9. All exposed conductors are 010 AWG PV-Wire unless otherwise noted. 10.Grounded conductors to be white or gray 11.All wire specified as "THHN" by The Solar Company is rated: THHN, THWN-2, MTW & AWN. 12.All Conduit to be labeled: "WARXING: PHOTOVOLTAIC POWER SOURCE". 13.Module Mounts and. Equipment Enclosures Grounded to Main Panelboard Ground or Ground Rod. 14.All SunPower (SPRm & SPRp), SMA (SB & TriPower) & SolarEdge Inverters have Arc-Fault Protection per NEC 690.11. System composed of I string of 10 & 1 string of 8 SunPreme SNPM-GxB-360 Modules connected to 1 SOLAREDGE SE760OA-US inverter. 18 Modules & 1 Inverter total. Array Ratings: DC Values: OPERATING CURRENT 19 AMPS OPERATING VOLTAGE 350 VOLTS D.C. MAX SYSTEM VOLTAGE 500 VOLTS D.4 SHORT CIRCUIT CURRENT 30 AMPS AC Values: OPERATING CURRENT 32 AMPS OPERATING VOLTAGE 240 VOLTS MAX SYSTEM VOLTAGE 264 VOLTS SHORT CIRCUIT CURRENT 40 AMPS L IFMf s 9J (E) 400A Main Panelboard w/ 200A Main Breaker (N) 40A 2-Pole Circuit Breaker w/ label: "Solar PV System" = Total DC WATTS / Operating Voltage = Inverter Operating Voltage = Inverter Maximum Voltage = 15 AMPS per String X # of strings Inverter OPERATING CURRENT x # of Inverters Inverter OPERATING VOLTAGE Inverter MAXIMUM SYSTEM VOLTAGE Inverter MAXIMUM TOTAL POWER RATING / NOM. AC VOLTAGE X 1.25 d6l Office (209) 676-3497 Fax (510) 888-9299 TheSolarCo.com r General Notes A R1 09MMM (N) 4x #10 PV-Wire Conductors (N) J-Box (If Needed) w/ label "Warning High DC Voltage" (N) 3 3" EMT or " FMC (if run 4 4 inside building) w/ #10 AWG THHN/THWN-2 or #10 AWG PV-Wire conductors and #10 AWG ground (N) SolarEdge SE760OA-US Inverter w/ Integrated DC Disconnect �—(N) Ground System (to meet 690.47) (E) Ground Rod Ground System (N) 34" EMT w/ #8 AWG THHN/THWN-2 conductors & #8 AWG ground, or (N) #8-3 Romex if AC wiring is run inside building ZU15 *E COMPLIANCE &I-) C) E-i U :4 CD a4 H I E-4 CD LO 04 C"i CD ::) Zr ­i U M ` 0.1 Revision/IsSue I Date) Date: October 27, 2015� Scale: N/A Drawn By: Darwin Ruiz Office (209) 676-3497 Fax (510) 888-9299 TSCde'sign@TheSolarCo.com Title* 3 SUNDARRAJ SINGLE LINE DRAWING Sh eet: "SUnPREME" Smart Siffoon' fo, Solar High Performance Bifacial technology generates power from both the front and back faces of the module, resulting in up to 20% higher energy harvest (kWh). N-type cells packaged in frameless double glass modules yield higher power and do not suffer from light-induced degradation (LID) or potential induced degradation (PID). Quality & Reliability S �J, Double glass modules designed for durability. Certified to international certification body Standards: IEC, UL, and CEC listed. Manufactured according to the International Quality Management System ISO9001, Extreme Climate Performance As temperatures rise, our patented SmartSilicon hybrid cell technology produces more power [kW] than conventional crystalline silicon solar panels at the same elevated temperature. Guaranteed Performance All modules have a 10 year product warranty and 25 year power output warranty. Superior Aesthetics Thin profile double-glass construction provides superior aesthetics that are a perfect complement to roots, carports, and canopies. About Sunpreme Sunpreme is an innovative solar PV module manufacturer headquartered in Sunnyvale, California with manufacturing facilities in the United States and China. We provide high quality, reliable and aesthetically superior modules to residential, commercial, and utility customers globally. Sunpreme solar systems are delivering clean energy in 9 different countries. Sunpreme solar panels are designed and engineered in Silicon Valley, CA, USA. SmartSilicon Technology Sunpreme modules use our patented SmartSilicon Hybrid Cell Technology platform technology that utilizes innovative thin- film materials on surface engineered Silicon base to achieve high-efficiency power output and reliable energy production for increased project returns. Unlike conventional silicon or thin-film technologies, Sunpreme uses highly - scalable process to deliver high efficiency solar power it very competitive Levelized Cost of Energy (LCOE). www.sunpreme.com I lnfo@sunprome.com Sunpreme: +1,408.245.1112 is �tyt. s ! 1 71 Y A I !Is 4J Dual-Glass Frameless Design Sunpreme Design is more robust, and does not require module grounding 10 YEAR PRODUCT WARRANTY 25 YEAR POWER WARRANTY Sunpreme's performance warranty obligations are insured with a Munich Re Group company, reinsured by Munich Reinsurance Company, a AA- rated rernsurer In head-to-head testing with a leading US manufacturer, Surpreme's Maxima GxEl panel outperforms the competition with over 20% higher power output, exceeding the STC Power rating under real world conditions P.-S, output as % of Poel, STC P- m, 5 U." sax i "SUnPREME' Maxima GxB 360W Bifacial Solar Module SmartSllicorf for Solar High Performance 72-cell N-type Solar Module ELECTRICAL 340 350 360 WARRANTY SPECIFICATIONS' 10 year extended product warranty STC rated output P., M 340 350 360 95% power warranty first 5 years Cell Efficiency 20,2% 203% 21,3% -0.6% per year degradation for the following 20 Module Efficiency STC 17.5% 18% 18.6% years Standard sorted output -3,Yo/+5% -3"/./+5% -39'.1+5% CERTIFICATION Open Circuit Voltage VC, (V) 51.3 51.7 52.1 Certified to UL 1703, IEC 61646, IEC 61730-01, Short circuit current is, (A) 9.0 9.1 9,2 IEC 61730-02, IEC 61701 standards, CEC & FSEC Rated Voltage V., (V) 41 41.6 41.9 listed, and CE mark Rated Current I,P, (A) 83 8.4 8.6 1: Standard Test Conditions for front-face of panel; 1000W/M, 25'C. -7 'Qus klj C E BI-FACIAL OUTPUT* w1th 10%, sacli-SIds Power Boost MECHANICAL SPECIFICATIONS Power Output M 374 385 396 1,959 x 990 x 6 mm (6.43 x 3.25 x Module Efficiency 19.3% 19.8% 20A% Dimensions 0.02 ft) WW7 _70%5ackslda Power Boost )"M* Power Output (W) 408 420 432 Area 1.94M2 (20,88 ft2) R Module Efficiency 21.0% 21.6% 223% Bifacial Mono N-type with *Sac I kside boost for flush mount applications resulting in I- 59.56 - 9.77 A Cefl type proprietary SmartSilicon Hybrid TEST OPERATING CONDITIONS Cell Technology (HCT) Operating Temperature - 40 to + 850C 72 Cells, Frameless double glass Storage Temperature - 40 to + 85 °C Module type design with tempered glass, no Maximum Series Fuse 15 A grounding required Maximum System Voltage 1,000VDC (UL & lEC) Glass Tempered 2.9mm, anti-reflective Power/Sq.Ft. w/ 20% backside power boost 20.1 W / Sq. Foot coating, low-iron SA00 Pa (snow load) Junction Box Tyco IP-67 rated; 1,000V UL /IEC, Maximum load capacity 185 ph wind rating 3 diodes m Fire Class Class A - Type 3 4mm2 x 0.9 m, cable: MC4 or MC4 TEMPERATURE COEFFICIENTS Cables compatible Tyco connectors 1.2m needed for landscape mount Temperature coefficient Pm,, -0.2856/C Temperature coefficient I., +0.035/./C PACKAGING Temperature coefficient Von -0.239/./C Modules per crate 26 Normal operating cell temperature (NOCT)'C 46C +/- 2 Crate per shipping container 22 1,... - V..(72 cell Version) Rear View (mm) Mounting method Side View (mm) Multi-irradiance Curve for Maxima Gx8 360 tea. rr Sao W/.-2 IIIWi­1=400W lalk 200 W!- ­ftev Iv) Covered by one or More of the fo3owing U.S. patents: 7,951,640; 79S6,2a3;7,96Q644 392 1,566 1,959 990 -Rail structure runs Parallel to short-side of module if in portrait mount on roof top (0.9m cable length) -Rail structure runs parallel to long-side of module in ground mount (1.2m cable length) Retaining clip of www.sunpreme.com I info@sunpreme.com Sunpreme: +1.408.245.1112 (%Sunpreme, Inc, All rights reserved. Rev Maxima GxB 360_1.1 r General Notes It '_ e 2s. NOV 9 2 4 '0`15 H to CD %No.l Revision/Issue I DateJ /Do.ot.. 7Ot.be,27, 2015 Scale: Drawn By: Darwin Ruiz Office (209) 676-3497 Pax ( 510 ) 888-9299 TSCdesignMeSolarCo.com Title: 5 Spec Sheet Module SunPreme GxB-XXX A F-I U-) F-� ­i U 1.4 9 C� r4 Z CD a4 1`--I I El I, 0i "o In a4 014 ;0 %No.l Revision/Issue I DateJ /Do.ot.. 7Ot.be,27, 2015 Scale: Drawn By: Darwin Ruiz Office (209) 676-3497 Pax ( 510 ) 888-9299 TSCdesignMeSolarCo.com Title: 5 Spec Sheet Module SunPreme GxB-XXX A Single Phase Inverters for North America solar @=a z solar =@@ SE3000A-US 1 SE3800A- US/ SE5000A-US I SE600OA-US I SE760OA-US SE10000A-US / SE1140OA- US SE3000A-U5 SE3800A USA SE5000A-US SE600OA-US SE760OA-U i SE1000OA- US i SE1140OA-US SolarEdge Single Phase Inverters ----- -- ... Nominal AC Power Output 3300 i 3840 9980 @ 203V 5000 6000 7680 i 1 . ....... 14,0099 9?�qy, 11520 VA 10800 @ 208V For North America Max. AC Power Output 3650 41 6000 8350 12000 i VA. .5 �q?50 @240V ....... ....... .. ..... .. . ..... AC Output Voltage Min.-Nom�-Ma0 SE300OA-US SE380OA-US SE500OA-US SE6000A-US .. ............ ,* SE7600A-US/SE10000A-US/ SE1140OA-US AC Output Voltage Miri.-Norn,-Max 211 - Vac J­­ AC Frequency Min.-Not -Max* 59.3 - 60 - 60.5 (with 24 @ 208V 48 @ 208V Max, Continuous Output Current 14 16 25 32 1 48 A 21 @ 240V ................. 42 @ 240V GFDI A Utility Monitoring, Isianding "Ier il, Protection, Country Configurable Yes Thresholds RD— Recommended Max. DC Power- 480 6250 750 9600 12400 14400 1 W 4100 0 0 (STC ... ....... Transformer -less, Ungrounded Yes M x 500 q, Nom, DC Input Voltage 325 @208V /450 @240V.,_.,., 25 @ 208V / 350 @ 240V VdC .... ......... ...... ........ ... .. .. . ... z - 1 33 @ 208V j Max. Input Current— 11 113 18 23,5 . 35 Adc 15,5 @ 240V i 30 I 'S 8V ............... .......... Current 30 45 Reverse- Ye ... . J...... Me imum Inverter Efficiency . 98., 9 % 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 g8 9TS 975 97.5 240V <2.5 <4 1 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, R5232, Ethernet, ZigBee (optiona() STANDARD COMPLIANCE 9 A Safety UL1741, UL1699B, UL19 8, CS 22.2 " Grid Connection Standards IEEE1 5 47 . Emissions FCC. partly class 8 — ----- ----- _jqSTAILAIO IfIC AC output conduit size/ AW6 ran 3/4" minimum 24-6 AWG 3/4' minimum/ 8 .. .......... DC input conduit size /# of strings 314" minimum J 1-2 strings 124- 6 AYVG t 3/4' minimum J 1 2 strings 14-6 AWG ........... .... . ...... ..... ..... . Dimensions with AC/DC Safety 30,5 x 12.5 x 7 30.5 x 12.5 x 7.5 in *, SWitch(i- 3xWxD) 775x3152172 F., X5 x 12.5 x 10,5 775 x 315 x 260 775 x 315 x 191 mm ............. . 51,2/23,2 5 �7 24.7 Weight with AC/ C Safety Switch ......... - 88,.4- / 40, , 1 " lb "kg Cooling Natural Convection Fans (user replaceable) .... . ..... ....... ....... Nose < 25 < 50 ..d SA The best choice for Solar Edge enabled systems Min.-Max. Operating Temperature Range. ...... -13 to +140/ -25 to+60 (CAN version*­ -40 to +60) .. Integrated are fault protection (Type 1) for NEC 2011690.11 corrilplan'ce Pratecnon Raring .. ... ........ NIIEMA,3fll 01 TIT, 711�11 t M% A The Solar Company, Inc. 20861 Wilbeam Ave. #1 Castro Valley CA, 94546 CSL# 596651 Office (209) 676-3497 Fax (510) 888-9299 TheSolarCo.com General Notes I CUPERTIN BGilding Departff NCIV 0 2 2015 br-li WAS- A 9eviewed By: J&.1 Revision/issue I Date Date: October 2�7, 2015 Scale* Drawn By* Darwin Ruiz Office (209) 676-3497 Fax (510) $88-9299 TSCdesign@TheSolarCo.com Title: 6 Spec Sheet Inverter Solar Edge SE3000 - SE1140CA-US Sheet: /. E-4 LO U 01 ;4 CD 04 H I CD LO 04 0V CD �D zll ,--q U c-, J&.1 Revision/issue I Date Date: October 2�7, 2015 Scale* Drawn By* Darwin Ruiz Office (209) 676-3497 Fax (510) $88-9299 TSCdesign@TheSolarCo.com Title: 6 Spec Sheet Inverter Solar Edge SE3000 - SE1140CA-US Sheet: /. ti ge Power Optimizer Module Add-On For North Americv. USA - GERMANY - ITALY - FRANCE IAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar SolarEdge Power Optimizer Module Add-On for North America P300 (P350 / P400 P405 P300 P350 P400 P405 L_ Todu (for 96-cell modules) (for thin film modules) 'I ��!Imodul JNPUT ... .... .. . . ...... Rated Input DC Power") 300 350 400 405 W ... .. ..... Absolute Maximum input Voltage (Vac at lowest temperature) 48 60 80 125 Vdc MPPT Operating Range 8-48 8-60 12.5-105 Vdc .. ........ ... Maximum Short Circuit Current 0sc) 10 Adc ..... ......... ..... . .. . .. .. ........... . .... Maximum DC Input Current Adc Maximum Efficiency 99.5 % ................. . ......... ....... . .......... ..... ... . ...... Weighted Efficiency 98.8 % ervoltage Category If _--------- ----- --- - J_ OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current .. ........... ..... ..... .. ...... ...... ....... . ..... ....... . maximum output voltage 60 85 Vdc ............ .. 11-1 _qUIP_qjYLIRING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer Vdc STANDARD COMPLIANCE ----------- -- ---- ,EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 .......... ...... ....... I .. .... ...... . ...... .. ..... * . ... .. . .... . . ..... Safety IEC62109-1 (class 11 safety), UL174.1 ..... ... ...... ...... ........ ........ ....... ............. . .. . ........... Yes _gym 'IN LATI ECffICATIONS ��AL _ T_kSP�_ ..._.._._..,._._..1004 _­­ -­­- ,Maxirnum Allowed System Voltage Vdc ...... . ........... ... ... 141 x 212 x 40.5 / 5.55 x 8.34 x 1.59 mm/in Dimensions (W x L x H) Weight (including cables) 950/2.1 gr/lb .. .. . ... .... * ............... * ........ . ........ Input Connector MC4/Amp hencil / Tyco 1__._MC4 .......... Output Wire Type /Connector 1 Double Insulated; Amphenol ........... Output Wire Lerlpth O, 95 3.0 1.2/3.9 m/ft Operating Temperature Range 40 - +85 1'40 - +185 ........... ---- Protection Rating. IP65 / NEMA4 ---------- ...... ...... ...... ...... Relative Humidity 0-100 Rated STCppeaur of the wpod[We_ hiodup of up to +5% pover tolerance a0oweo, PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERill Minimum String Length 10 18 (Power Optimizers) ........... ............ .. ...... ...... . Maximum String Length 25 (Power Optimizers) 25 50 Maximum Power per String ...... 6000 12750 W ... .. ............... .. .... .. . ... Parallel Strings of Different Lengths Yes �r Orientations ....................... u",i, on.,01—of to rei, P405 with F3W/F.450194W/P60Q/P700 in one sting. M General Notes nip CUPERTINO Buis ding Department 2 2 0 W3 :7"A"E'D FOR CODE COMP rai-mWed BY: Tpw� z vs E-4 Ln E-' U 0 Z (D 124 F-i I E-4 C:) in a4 N �D No. Revision /Issae Date M solar SolarEdge Quick Installation Guide - North America L I Mount the power optimizers, in a shaded location near the PV modules, on the structure or racking to which the module is attached, using the mounting holes. If possible, avoid mounting power optimizers in locations where they will be exposed to direct sunlight. Make sure that each power optimizer is positioned within reach of each module's cables. To allow proper heat dissipation, maintain a 1" /2.5 cm clearance distance between the power optimizer and other surfaces. 2 Attach each power optimizer to the rack using the 5/16" or 1/4" bolts, nuts and washers. 3 Use the following methods to ground the power optimizer: Star we • For mounting on a grounded metal rail: Use the provided 5/16" stainless steel grounding star washer between the railing and the flat side of the mounting bracket. The grounding washer should break through the anodize coating of the railing to ensure low resistive connection. Apply torque of 9.5 N*m / 7 lb*ft, For mounting on rails with sliding nut fasteners, or an un-grounded structure to (such as a wooden structure): Connect an equipment-grounding conductor to the grounding terminal according to the instructions supplied with the grounding terminals (grounding terminal kits are available from SolarEdge). The grounding terminal accepts a wire size of 6-14 AWG, and must be sized for equipment grounding per NEC 250.122 requirements. Tighten the screws connecting the power optimizer to the frame and the grounding terminal screw. Apply torque of 9.5 N*m / 7 lb*ft. 4 To benefit from the physical mapping of the installation in the SolarEdge Monitoring Portal, record each power optimizer's serial number and location: Peel off its removable barcode sticker and stick it on the mapping template, or scan the barcode with the SolarEdge Whone Site Mapper app. Upload the map to the SolarEdge website, using the site registration form. 5 Connect the Plus (+) output connector of the module to the Plus (+) input connector of the power optimizer. 6 Connect the Minus (-) output connector of the module to the Minus input connector of the power optimizer. Connecting Power Optimizers in a String Bracket Input Connect to module Connect the power optimizer outputs in series: Connect the Minus (-) output connector of the string's first power optimizer to the Plus (+) output connector of the string's second power optimizer. Connect the rest of the optimizers in the string in the same way, ...... • The minimum and maximum string length should be according to the power optimizer datasheet. • Strings DO NOT have to be of equal length. 2 Verify proper connection of power optimizers: Before the inverter is turned ON, each power optimizer produces Wsafety-voltage. Use a voltmeter to verify it for each string using a voltmeter. The voltage on a string is the number of modules multiplied by 1V, with a deviation of 10mV per module. Make sure the modules are exposed to sunlight during this process. • If several strings are connected in parallel, verify voltage for each string. separately M97111 2 Office (209) 676-3497 Fax (510) 888-9299 TheSolarCo.c" f General Notes A MEWED FOR CODE CC) W U-0eviewed By: Z Cl) C) E-4 LO H C3 F4 Z cD 124 F--I 1 Lr) a4 c,,i ;44 !LNo.1 Revision/Issue I Date) Date: October 27, 20 Scale: Drawn By: Darwin Ruiz Office (209) 676 -3497 Fax (510) 888-9299 TSCdesicjn@TheSolarCo.com Title: 8 Spec Sheet Solar Edge Power Optimizer Grounding �Sheet: 8 L � 151 WARNING! ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS! 11 1 AMA I imo c-1 ws J� Notes: 1. Labels are reflective, weather resistant and suitable for the environment. They are all capital letters with $" white on red background. 2. Markings are placed every 101, within 1' of turns or bends & within 1' above and/or below penetrations of roof/ceiling assemblies, walls or barriers. M Office (209) 676-3497 Fax (510) 888-9299 TheSolarCo.com r General Notes I t FOR CODE COMPL awed By: - C D Ln 0) U woo 04 H El 01 m r4 �,o 1--i W I U-) P4 N rpti 0 � -,T '-q U (n kNo.1 Revision/issue I Date.) I'D.t, October 2�7,2075 Scale; Drawn By: Darwin Ruiz Office (209) 676-3497 Fax (510) 888-9299 TSCdesign@TheSolarCo.com Title: 9 Labels Spec Sheet Sheet: 9