Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2016-1847
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1847 11698 OLIVE SPRING CT CUPERTINO, CA 95014-5141 (366 54 101) WEST COAST SOLAR INC BRENTWOOD, CA 94513 OWNER'S NAME: GUPTA KRISHNA TRUSTEE OWNER'S PHONE: 408-516-3900 LICENSED CONTRACTOR'S DECLARATION License Class C-46 Lic. #9p8549 Contractor WEST COAST SOLAR INC Date 12/31/2017 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date 4/28/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. 1 have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. s. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date 4/28/2016 DATE ISSUED: 04/28/2016 PHONE NO: (925) 516-3900 BUILDING PERMIT INFO: X BLDG X ELECT —PLUMB _ MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: INSTALL 22 PV SOLAR PANELS ROOFTOP MOUNTED (5.72 kW); ADD (N) SUB PANEL (100 AMP) FOR SOLAR ONLY (MUST BE LISTED FOR SOLAR ONLY - VIF) Sq. Ft Floor Area: I Valuation: $20000.00 APN Number: Occupancy Type: 366 54 101 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Alex Vallelunea 46�0:�� Date:04/28/2016 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 4/28 2016 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the - California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Owner odaffior ecl ag`eiit: Date:4/28/2016 CONSTRUC N LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professic ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildin4n.cupertino.org PROJECT S I APN " ©I i ve. r -� —Sb&— OVJt cRNA1,4E I PHONE "a - L4 L10- is � E-MAIL°> STREET ADDRESS CITY, STATE, ZIP I FAX CONTACT NAM " n � tV,, A 0,�" 1 PHC]? c pia5 SICK �gcrJ E-MAIL o.st-mviC WeSfiCoo&&fsc�l�rc� SiPs-T RESS CITY, STP.TH, ZIP �n v CiH 5 l FAX ❑ OGr.:-R ❑ OWNER -Bull -DER ❑ OV'17=R AGEV, ❑ CoNn.ACTOR YI'COXiR',CTOR AGE..-r ❑ .AaC17tT.CT ❑ E 1"GINTER ❑ DE-\sLOPER ❑ T7--1.Axrr CONy��CI OR 'AT6E O cxv- LICE.' ! y LICFSE TAPE �i BUS. LIC V 1 COMPANY NAMM 'wPS Cd _ S�l�t� E- L "1v 0 � w CO O'G+SofgV_ Cow rAJ sTi'�1 CITY, 2✓��Cl'('4 G 11 q)WE'51 ARCHITECT1FNGINEER NAME LICENSE I\IUMBER BUS. LIC 4 COA4PANY NAME I E-M.A1L FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF IrSFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO -IPSOLAR PANELS I ❑ ELECTRIC VEHICLE CY ARGING STATION ❑ SOLAR WATER 171EATING ❑ OTHER: FOR SOUR PAIYELS: NUA!BER OFF 2LS/UNITS: KILOWATTS (C���� 1�: C; � 2 TOal L \/ .LU JTIION: DESCRIPTION OF WORK v15 1(a1' is 5 e 7 I,,-,Ji- v IGw- t-co-, OvAd��W.. �i1Vl�� i (00 -• 1. - cJ n I REC I� tD B ' P By my signature below, I certify to each of the following: o I am the property owner or authorized agent to act on the proper's behalf. I have rea , application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating ilding c nstruction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. S ignatur e. of Applicant/Agent: Date: 3 C3 PPLEME;�TTAL I-NTFORMATION REQUIRED = - - y OFFICELi�E-D �ZY ` - OV THE COUIZ2ER = -ER _ - :r. _ - L M-M P I!4pp_201 J.doc revised 03116111 COMMUNITY MANAGEMENT SERVICES, INCORPORATED April 26, 2016 Krishna Gupta RECEIVED Ram Gupta 11698 Olive Spring Court - Cupertino, CA 95014-5141 BY - Re: SEVEN SPRINGS OWNERS ASSOCIATIONS 11698 Olive Spring Court Dear Homeowners: Enclosed you will find a copy of your Architecture Application for the installation of solar panels on the roof of your home, with the approval from the Board of Directors, as well as any restrictions or conditions that the Board deemed necessary. Please fill out the final inspection form and return to me once your project is completed. Please keep in mind that any deviation from your approved application will require you to resubmit your application for review. If you utilize an unapproved material you will be required to remove and replace the material with an approved selection. The approval of your project's architectural compatibility with the Seven Springs Owners' Association's complex does not constitute or imply, that the Architectural Committee and/or the Association Board of Directors deem your project as meeting City of Cupertino /County of Santa Clara codes. The approval is given contingent upon you and/or your contractor(s) obtaining the required construction permits and meeting all code requirements, if any. Sincerely, Community MaAagement Services, Inc. Luis Heredia, Senior Association Manager, CCAM SEVEN SPRINGS OWNERS ASSOCIATIONS cc: Board of Directors 1935 Dry Creek Road, Suite 203 • Campbell CA • 95008-3631 • voice (408) 559-1977 9 fax (408) 559-1970 Seven Springs Owners Association Application for Approval of Architectural Change/Addition CATEGORY C Catcgon C - Modificatiuns that arc exterior modifications with no changes to the original building structure or floor plan. All roofing. siding, window material change, exterior paint color change, addition of a roof attic fan, or garage door, fall into this category. Date: S lLr�Q14 Request for Approval of Proposed Change PLEASE PRINT THE FOLLOWING INFORMATION Name: kKll&l Al o C-, up n Address: t �__(,�� i►1 � 2f� t-- CUI���cco t C� [lame Phone: 0 Work Phone: email: Descripthm of Proposed Change: f I) Paint Color Change: Please choose from "approved list" (Garage door outer trim should be diamond white or frost) %eft h tfrYa,,r Sidwti Cohir l Garaged .,r(%I wunt, rolor, specified color Trim color: diamond white _ or frost Front door color, diamond white _ frost _ _ natuial oak — or specified "approved color' 0 2) Roofing Material Change (please check one choice) a. Lightweight Concrete Tile from. MonlerLifedle -."style "Cedarlite 5780", color "Muirwood" b. GAF Laminated Fiberglass Asphalt - style "Grand Canyon", color "Mission Brown" c. GAF Laminated Fiberglass Asphalt - style "Grand Canyon", color " "Stonewood" d. Decra Stone Coated Steel Rood System- style'-Decra Shake", color "Shadowood" e. Class "A" Fire Retardant Roofing System using pressured treated cedar wood shingles with fire retardant fiberglass cap sheet underlay. Need to have a City of Cupertino Permit accompanying this application for all wood shingle roofs. 03) Siding Mat"I Change (Please check one choice) Siding Material: Flardiplank Cedarmill (wood grain finish) or Hardiplank Smooth Finish Which sides am you are changing material? ( front " back _left _ right _ ) ,U04) Window Material and Design change: (Please check this box): Vinyl Windows - color White #Must include manufacture also Include cut sheet for type and style of windows. Retrofit ^New Constr. viz 5) Adding 9 roof attic fan, Tubnlnr Skylight, Air Conditioner (location of Condenser), and Satellite Dish Please attach information regarding'the proposed change Application must include dimension, color of -the proposed fan and its location on the roof. Please include detailed drawings, specifications. and.product brochures if available. Tubular skylight up to l4" diameter, one roof attic fan up to 26" In width & height - paint to match roof N Q 6) Garage doors: a_ Recessed wood panel, not raised in center same style for windows ("PLAIN" - non decorative) Style 84 (g panels across, 64 (6 panels across), 44 (4 panels across). Style __ with windows or Style — no windows b. Insulated wood, insulated metal w/ wood facing or "Carriage House" style 303C windows _ 303 no w'mndow GS 7) lar System: Adding solar panels to the roof of home. ( (Requires drawing indicating placement of panels and photo for type of panel to be installed) 8) Any additional exterior modification: (please Wd4') Homeowner's Signature: I I rw The request is in compliance with Seven Springs HOA Architectural Guidelines: http://seven-springs.org/filedarchitectual-guidelines.pdf Architccttual Control Cotntnittee/Board: Approved Pending Denied Pending Architectural Control Committee Board: Signature: 1.27.1 I cat C Date: Scanned by CarnScanner m F-FIC":OD OTOVOLTAIC SYSTEM 5.72KW DC �y pry!�BY E I'"`- Z " -E a,r;, ,t C"UPERTI g-yea CEIVED GUPTA RESIDENC 4 U J Suildina Depan _e EPA' ZLLUu F 11698 OLIVE SPRING CTO?R �: RiL �. ���I �: �� ERTNO • '.. zrn " CUPERTINO CA 95014 RE1�lE1NE[� FaR CODE COt�1PLIA�iCE W2 �"w LO Rpvipwed By: N PROJECT DATA PROJECT ADDRESS: OWNER: CONTRACTOR: DESIGNER: 11698 OLIVE SPRING CT., CUPERTINO, CA 95014 KRISHNA GUPTA 11698 OLIVE SPRING CT., CUPERTINO, CA 95014 408-446-1270 WEST COAST SOLAR INC. SCOPE: 5.72kW DC ROOF MOUNT SOLAR SYSTEM WITH 22 HYUNDAI 260 PV MODULES AND A 22 ENPHASE MICRO INVERTERS - M-215. APN: LOT AREA: LIVING AREA: 018-370-012-9 5,062 SQ.FT. 2,445 SQ.FT. COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION - CUPERTINO APPROVED This set of plans and specifications MUST be kept job sits: during construction. It is unlawful to makE chin os or alterations on same, or to deviate therefrom, without approval from the Building Off Tho stamping of this l bo held to pEerm' . or of any pr N afi BY DATE �( } PERMIT NO. . and specifications SHAL pproval of the viol City rdinance or State GENERAL NOTES 1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. 2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE 2013 CEC AND 2013 CBC. 3. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 4. A DC DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF THE BUILDING OR STRUCTURE OR INSIDE NEAREST POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS AS PER SECTION 690.14 OF THE CEC. 5. HEIGHT OF THE INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24. 6. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 7. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 8. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. THE SMOKE ALARMS SHALL BE INSTALLED OR VERIFY TO ENSURE THE SMOKE ALARMS ALREADY EXISTING WHEN ALTERATION OR REPAIR TO GROUP R-30CCUPANCY EXCEEDS $1,000 CRC R314.6. A. ON THE CEILING OR WALLS OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS B. IN EACH ROOM USED FOR SLEEPING PURPOSES, C. IN EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. D. ALL SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL217 AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. SYSTEMS AND COMPONENTS SHALL BE CALIFORNIA STATE FIRE MARSHAL LISTED AND APPROVED IN ACCORDANCE WITH CA CODE OF 114�§ULATIONS, TITLE 19, DIVISION1 FOR PURPOSE FOR WHICH THEY ARE INSTALLED. 'MRBON MONOXIDE ALARMS IF NOT ALREADY EXISTING ARE REQUIRED TO BE INSTALLED WITHIN A DWELLING WHEN THE VALUATION OF AN ADDITION, ALTERATION OR REPAIR TO GROUP R-3 OCCUPANCY EXCEEDS $1,000 CRC R315.2 4GARBON MONOXIDE ALARMS ARE REQUIRED AT THE FOLLOWING LOCATIONS: MOTN THE CEILING OR WALLS OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS ON EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS. C. THE CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WITH THE REQUIREMENTS OF UL 2034. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THIS CODE, THE CURRENT EDITION OF NFPA 720 MLANDARD FOR THE INSTALLATION OF CARBON MONOXIDE (CO) DETECTION AND WARNING EQUIPMENT" AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER 2010 CRC SECTION R315.3. PV-1: PV-2: PV-3: PV-4: PV-5: PV-6: PV-7: SPA: SP-2: SP-3: SP-4: SP-5: VICINITY MAP Rainbow Or Rainbow Dr - seen 1*1sDr' u� cn m ,i,orangeStassomDi ' S Peach Blosmm Dr.': y't.cn'j ; Q `Normandy J9a�, ; Newcastle Dr ,? watertdfdDr 9T i, tAAsp ata02016_Google SHEET INDEX I COVER SHEET SITE PLAN ROOF PLAN FRAMING PLAN SINGLE LINE DIAGRAM SIGNAGE SCHEDULE OPTIMIZER MAP MODULE SPEC. INVERTER SPEC. RACKING SPEC. STANDOFF SPEC. GROUNDING SPEC. CODE REFERENCES PROJECT TO COMPLY WITH THE FOLLOWING: CALIFORNIA CODE OF REGULATIONS, TITLE 24 2013 CALIFORNIA BUILDING CODE (CBC) 2013 CALIFORNIA.MECHANICAL CODE (CMC) 2013 CALIFORNIA PLUMBING CODE (CPC) 2013 CALIFORNIA ELECTRICAL CODE (CEC) 2013 CALIFORNIA ENERGY CODE INSTALLATION TO COMPLY WITH ARTICLE 690 OF THE 2013 NEC. U 0 W z W N Cn L0 Z H0 CDLL O a a U Z� N 01, m0 �o aQ o UU M > O DO C� pro °D QZ �UQ 1 RFVIGITINS 1 II�Y DRAWN BY: LK/AB DATE: 3/30/2016 SCALE SHEET TTRE TITLE SHEET PV-1 A(; ng Departmen -3 'U 100.50, _ _ _ — — — — I I ARRAY 3 I 3 MODULES 0° AZIMUTH 210 TILT I I I I in NI I I T I �� 0Ln I I I I v � I L), I OLIVE SPRING COURT (E) DRIVE WAY ,m 18" M1N. I ❑ 3- MIN. ARRAY 2 4 MODULES I 1s" 90" AZIMUTH � MIN. "= 210 TILT I I I �__ - --- - I I SUB —PANEL 1800 AZIMUTH 210 TILT 1 RFVISIf1NC 1 DRAWN BY: LK/AB CUPERTINO Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By. KEY / COMPONENTS SYMBOL DESCRIPTION NEMA 313 JBOX ❑ ENPHASE MICRO INVERTERS - M-215 - - - - - 4" EMT CONDUIT PV MODULE GENERAL NOTES: 1. 21 DEGREE 2. 2X4 DF TRUSS @ 24" O.C. 3. COMPOSITION SHINGLE 4. (22) HYUNDAI 260 PV MODULES 5. (22) ENPHASE MICRO INVERTERS - M-215 6. IRONRIDGE XR-10 RAIL 7. IRONRIDGE FLASHFOOT 8. WEEB CLAMPS & LUGS FOR PV GROUNDING i MEMO DRAWN BY: LK/AB LOAD CALCULATION System Size 5.72 kw DC Module: H undai 260 Total Modules 22 Module weight-Ibs. 46.7 Total module weight 1027.40 Ra cki ng Ibs./module 1 total racking weight-Ibs 22 TOTAL ARRAY WEIGHT 1049.40 MODULE AREA 17.485 TOTAL ARRAY AREA 384.67 Lbs./S .ft. (less than 5 - OK) 2.73 number of vertical supports 28 Lbs. per support (less than 45 -OK) 37.47857143 PV MODULE wilding Departmen u: J 0 �C 0 mt— 0 ` I` `n I� �' REVIEWED FOR (;(-)DE COMPL 00 :.. � o / Q ui I, � ° 3 J SEE MOUNTING DETAIL Reviewe(� BY, ` f�� m -1 i J �I:.:.�.:v.:. o IRONRIDGE XR-10 RAIL ui o' & IRONRIDGE FLASHFOOT / co N ;! Z o, w Lo 2X4 DF TRUSS @ 24" O.C. FRAMING CROSS SECTION SCALE: N.T.S. r— — — — — — — — — — — — — — — — — - PV MODULE IRONRIDGE XR-10 I RAIL I COMPOSITION SHINGLk IRONRIDGE ROOFING I FLASHFOOT 5/16"x3" LAG SHEATHING SCREWS ON 2.5" MIN. EMBEDMENT 2X4 DF TRUSS @ 24" O.C. L_ — — — — — — — — — — — — — — — — — MOUNTING DETAIL SCALE: N.T.S. 0 0 Lu V Y Yvrn Lu N 04 ��o �u �Qo U M Z W LL Cu 0 00 O E_ O C 0 a. 00 tZ z �UQ �L 0 a a RFVISI(]NS 11111111 amommomm DRAWN BY: LK/AB DATE: 3/30/2016 SCALE: SHEET TfRF FRAMING PLAN SHEET: PV-4 (E)125A/240V MAIN SERVICE PANEL O (N)30A ' SOLAR ONLY SUB -PANEL BREAKER GROUND ° AC CURRENT 2 - #8 THWN-2 CONDUCTORS 1 -#8 THWN-2 NEUTRAL 1 -#8 THWN-2 GROUND IN 1 -%" EMT CONDUIT WIRE RUN NOT MORE THAN 10' NOTES: (N) 100A/240V SUB -PANEL NEUTRAL (N) 15A 2P OLAR BREAKER (N)15A 2P SOLAR BREAKER (E) 15A 1P SOLAR MONITORING DEVICE BREAKER GROUND ❑® SOLAR MONITORING DEVICE ETHERNET CABLE TO ROUTER ]-BOX NEMA 3R AC CURRENT 2 - 10/3 ROMEX (IN ATTIC) 1 -#6 GROUND AND/OR 4-#10 THWN-2 CONDUCTORS 4 - #10 THWN-2 NEUTRAL 1 -#8 THWN-2 GROUND IN 1 - % CONDUIT WIRE RUN NOT MORE THAN 100' ILBuilding CUPERTINO Department REVIEWED FOR CODE COMPLIANC Ft e L 22 HYUNDAI 260 MODULES AND 22 ENPHASE MICRO INVERTERS - M-215 INVERTERS BRANCH CIRCUIT #1 -11 MODULES AND MICROINVERTERS o nEO �� o loi,4m BRANCH CIRCUIT #2 -11 MODULES AND MICROINVERTERS 1. 22 HYUNDAI 260 PV MODULES 2.22 ENPHASE MICRO INVERTERS - M-215 INVERTERS. 3. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT -RESISTANT ENPHASE TRUNK CABLE AS PERMITTED BY CEC 690.31(B). 4. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). THERE ARE NO DIRECT CURRENT CIRCUITS PAST THE MODULE TO INVERTER CONNECTION. 5. WEATHERPROOF J-BOX - NEMA 3. 6. (N) SOLAR ONLY SUB -PANEL. ADD TWO(2) 2 POLE 15A FOR SOLAR BREAKER AND 1 POLE 15A FOR SOLAR MONITORING DEVICE. 7. (E) 125A MAIN SERVICE PANEL. ADD 30A BREAKER TO SUPPLY (N)100A SOLAR ONLY SUB -PANEL. 8. ALL WORK SHALL COMPLY WITH THE 2013 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 'I 0 Li PV SOURCE CIRCUITS AC CURRENT 2 - ENPHASE INVERTER TRUNK CABLE 1 -#6 GROUND 11111111 oommoomm DRAWN B1': LK/AB C: UP ERTIN Building Depertm rg o q. LABEL SCHEDULE--� W iw- l o REVIEIJVt�=D For,, CODE COfVIPLIAIV aDU Ie.: \I- A Reviewed By: �� � > 'F ` �' CD LL, Q � ` Z m R v J W Lo Ln O1 CAUTION •- • A • j _ C1 ONLY! OPERSONNEL v -.•• • -• • ARRAY NOMINALOPERA I INU VULa Voc 0 • �` LAR,, AC CURR ENTPIRESENT 9 J-BOX L!J LU DURING DAYLIGHT HOURS o (STICKER TO BE LOCATED ON ` Lo U p CONDUIT WITH AC CURRENT 2 LU i— a) c? EVERY 4' HORIZONTALLY OR W Z > c 00 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) Z) O o O a0 C z n O. `r°UQ = 0O 10 ® SOLAR ONLY SUB -PANEL (STICKER LOCATED INSIDE PANEL Og Og NEXT TO PV BREAKER) a 10 11 a REVISIONS INVERT�R,OUTPUTCONNECTIQN DO. NOT RELOCATET HIS (STICKER LOCATED INSIDE PANEL METE BELOW PV BREAKER) MAIN SERVICE PANEL O O 10 11 DRAWN BY: LK/AB DATE: 3/30/2016 SCALE SHEEP TRLE: SIGNAGE SCHEDULE SHEET: PV-6 ���1111 ARRAY 3 3 MODULES 0° AZIMUTH 210 TILT ARRAY 1 15 MODULES N[j� 1800 AZIMUTH 210 TILT PERTINO s s, 3uilding Departmer REVIEWED FCIIj COOT rnMpLIANCE 5.72 kW DC (STC) Reviewed By: 22-HYUNDAI 260 MODULES & 22-ENPHASE MICRO INVERTERS - M-215 INVERTER 1 RFVICIr1NC 1 1= IL_ 5 0 a 0 ARRAY 2 4 MODULES = ®®® 900 AZIMUTH DRAWN BY: 210 TILT LK/AB www.hhi-green.com/solar Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company. The company employs more than 48,000 people, and has a global leading 7 business divisions with sales of 60.2 Billion USD in 2012. As one of our core businesses of the company, Hyundai Heavy Industries is committed to develop and invest heavily in the field of renewable energy. Hyundai Solar is the largest and the longest standing PV cell and module manufacturer in South Korea. We have 600 MW of module production capacity and provide high -quality solar PV products to more than 3,000 customers worldwide. We strive to achieve one of the most efficient PV modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies. Multi -crystalline Type RG-Series HiS-M250RG I HiS-M255RG 1 HiS-M260RG Mono -crystalline Type Hi5-S260RG I HiS-S265RG I HiS=S270RG )Mechanical Characteristics pVg ED �I ('&- ,_ P� �� Imp HYU N DA �1FD �.�0 � � �' � r'� HEAVY INDUSTRIES CO.,LTD. CUPER AN r..af 6i.lilding DeX Electrical hzlraclerlstica Multi -crystal line Type Nominal output (Pmpp) w 250 255 -" "AO Voltage at Pmax (Vmpp) V 30.9 31.0 31.1 Current at Pmax (Impp) A 8.1 8.2 8A Open circuit voltage (Voc) V 37.4 37.6 37.7 Short circuit current (Isc) A 8.7 8.8 8.9 Output tolerance % +3/-0 No. of cells & connections PCs 60 in series Cell type 6" Multi -crystalline silicon (Hyundai cell, Made in Korea) Module efficiency % 15.3 15.6 15.9 Temperature coefficient of Pmpp %/K -0.43 -0.43 -0.43 Temperature coefficient ofVoc %/K -0.32 I 0.32 -0.32 Temperature coefficient of Isc %/K 0.048 0.048 0.048 X All data at STC (Standard Test Conditions). Above data may be changed without prior notice. Mono -crystalline Type Nominal output (Pmpp) W 260 265 270 Voltage at Pmax (Vmpp) j V 31.1 31.3 31.4 Current at Pmax (Impp) A 8.4 8.5 8.6 Open circuit voltage (Voc) ; V - , 37.9 38.1 38.2 Short circuit current (Isc) A 8.9 9.0 9.2 Output tolerance % ! +3/-0 No, of cells & connections PCs 60 in series Cell type - 6"Mono-crystalline silicon (Hyundai cell, Made 1n Korea) Module efficiency % 15.9 16.2 16.5 ,.Temperature coefficient of Pmpp . %/K . -0.45 - -0.45 - -0.45 . Temperature coefficient ofVoc %/K -0.33 -0.33 -0.33 Temperature coefficient of Isc I OWK 0.032 0.032 0.032 X All data at STC (Standard Test Conditions). Above data maybe changed without prior notice Module Diagram 9 / / / \. C HOLES I=- lOOD. D93T1 (393n 4mm'CABLE a 4mWCABLE& CONNECIOB CONNECrOR 8 /GROUNDMARK "4x042 GROUND HOLE Installation Safety Guide • Only qualified personnel should install or perform maintenance. Be aware of dangerous high DC voltage. • Do not damage or scratch the rear surface of the module. • Do not handle or install modules when they are wet. (unit: mm, Inch) I-V Curves Curr°nt(AI 9 - 5'C a LOGOW/W -ss.0 7 6 - 4SC 65•C DETAILA 8-075LOTTHRU l z � B 037 °0 5 ID 15 0o u w 35 ao as C-nt[A) VokageM DETAILS ° IB (0.71� ' - l,oaowim� 6-600W/W t -400wilwIW -200lm'1 1B 0.07 z SECTION C{ o o to zo m w m V°U,9eM �i 46'C±2 _. - -40 - 85•C 11,"�•_�, tL.�.�"� u.'� ��tir DC600V(UL) 15 A Sales & Marketing Printed e-fi- pc certified 2n° Fl , Hyundai Bldg., g g g •�fri°p wFSC°, Y g.,75,Yu1 ok-ro,Jon no- u,5eou1110-793,Korea FSC Tel:+82-2-746-9406,7422,8525 Fax:+82-2-746-7675 [ Printed Date: January 20141 HYU N DAI HEAVY INDUSTRIES CO.,LTD. 1 RFVISIONS 1 11111111 nommomom DRAWN BY: LK/AB Enphase Microinverter Model M215 M215 Specifications Enphase M215 Microinverter Parameters; Topic unit Min _Typical Max.' DC Parameters ' MPPT voltage range V 22 36 Operating range V 16 36 Maximum DC input voltage V 45 Minimum / Maximum start voltage V 22 45 Maximum DC input short circuit current A 15 Maximum DC input current A 10.5 Ground fault protection mA 1000 Maximum input source backfeed current to input source A 0 Enphase M215 Microinverter Parameters, i ',Topic Unit Min Typical Max i AC Parameters Rated (continuous) AC output Power (40 to +65°C) W 215 Output power factor 0.95 0.99 1 Nominal AC output voltage range 240 VAC (split phase) 208 VAC (three phase) Vrms Vrms 211 183 240 208 264 229 Extended AC output voltage range 240 VAC (split phase) 208 VAC (three phase) Vrms Vrms 206 179 269 232 Maximum AC output current at nominal voltage 240 VAC (split phase) 208 VAC (three phase) Arms Arms 0.9 1.0 Nominal AC output frequency range Hz 59.3 60 60.5 Extended AC output frequency range Hz 57 60 160.5 Maximum AC output over current protection device A 20 Maximum AC output fault current & duration Arms/cycles 1.05 Arms over 3 cycles 1.04 Arms over 5 cycles High AC Voltage trip limit accuracy % t2.5 Low AC Voltage trip limit accuracy % 34.0 Frequency trip limit accuracy Hz t0.1 Trip time accuracy ms ±33 Miscellaneous' Parameters { Maximum inverters per 20 amp AC branch circuit 240 VAC (split phase) 208 VAC (three phase) 17 25 Peak inverter efficiency % 96.3 CEC weighted efficiency % 96.0 Static MPPT efficiency (weighted, ref EN 50530) % 99.6 Total Harmonic Distortion % 3.0 5 Operating temperature range (internal) °C -40 85 Ambient temperature range °C -40 65 Night Tare Loss mW 46 Storage temperature range °C -40 65 CUPERTINO 'wilding Department REVIEWED FOR, ICODE COMPLIANCE Enphase M215 Microinverter Parameters Topic Unit Min Typical Max .; Features and Specifications { Compatibility Pairs with most 60-cell PV modules Dimensions not including mounting bracket (approximate) 17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.0") Weight 3.5 Lbs (1.6 Kg) Enclosure environmental rating NEMA 6 Torque specifications for fasteners 6 mm (1/4') mounting hardware: 5 N m (45 to (Do not over torque.) 50 in-Ibs) 8 mm (5/16") mounting hardware: 9 N m (80 to 85 in-Ibs) Torque specification for 10132 ground cleat 2 N m (20 to 25 in-Ibs) (Do not over torque.) Cooling Natural convection: no fans Communication Power line Standard warranty term http_llenphase.comlwarranty Compliance UL1741, IEEE1547, FCC Part 15 Class B CANCSA-=2 NO.0-M91, 0.4-04, and 107.1-01 Integrated DC disconnect The DC connector has been evaluated and approved for use as the load -break disconnect required by the NEC. Integrated AC disconnect The AC connector has been evaluated and approved for use as the load -break disconnect required by the NEC. Engage Cable Specifications "Specification'. value System temperature range (ambient) -40°C to +65°C (-40°F to 149°F) Cable temperature rating 90°C Dry / 90°C Wet Cable type TC-ER Cable conductor insulator rating THWN-2 Environmental protection rating IEC 60529 IP67 UV exposure rating: terminator, engage coupler, and drop connector body UL 746 C, F1 Sunlight resistance (cable) UL 1277 Compliance UL486A/B, UL 514C, UL6703, UL 9703, IEC 60529 IP67, CANICSA 22.2 No. 21, 182.3 Conductor size 12 AWG Cable diameter 1.25 cm (0.49") Minimum bend radius 4.75 inches (12 cm) Drop connector dimensions 11.8 cm x 6.0 cm x 3.2 cm (4.64" x 2.36" x 1,25") Terminator cap dimensions 3.6 cm diameter x 5.1 cm tall (1.4" x 2") 1 PpylclnKlq 11111111 1111000021021 DRAWN BY: LK/AB ZIZ__ a. IRONRIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability :y r requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Force -Stabilizing Curve Sloped roofs generate both vertical and lateral *k` forces on mounting rails which can cause them ,i to bend and twist. The curved shape of XR Rails x is specially designed to increase strength in both x directions while resisting the twisting. This unique feature ensures greater security during extreme � =. ��+-� ' r,�,, �= r �#,� ,• :" weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with r��l a range of tilt leg FlashFcot and options for flat other pitched roof roof mounting attachments. applications. i« �i Suilding Dep J �COM L XR Rail Family XR Rail Family REVIEWED Er� CODE Reviewed By: _ - The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. Corrosion -Resistant Materials All XR Rails are made of marine -grade n aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing �- a more attractive appearance. XR10 XR100 i XR10 is a sleek, low -profile mounting XR100 is the ultimate residential rail, perfectly matched to regions mounting rail. It supports a range of Ci without snow. It achieves 6 foot spans, wind and snow conditions, while also li while also staying light and economical. maximizing spans. 6'spanning capability 8'spanning capability Moderate load capability Heavy load capability ' Clear anodized finish Clear & black anodized finish Internal splices available Internal splices available Rail Selection XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. • 12' spanning capability Extreme load capability Clear anodized finish Internal splices available No °o v I�.. rp I F_ •rFi � 1�_, r i Q ����^{I ED V !� J If } (6 ,, i U') t w ZN Y v J W N -1 " The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. a ll- ,,."e�'"# }. haj. - b� • ®. •tW i y ¢j yk s , 100 ' 120 ;'•. None - 6 140 XR10 XR100 ;. XR1000 160 - �^ ^ 100 . f 120 i 10-20 140 110 i i 100 30 160 i 100 40_� i 160 50-70 160 80-90 160 t 0 LLI U� Z N UJ �Z Fa-- O =)LL 0 O �vrn U N mo c 'n o) o nQ o U U C) o Do • c� pro Do QZ �UCL Q 1 RFVISIONS 1 11111111 0000002121 DRAWN Bf: LK/AB DATE SCALE: SHEET TREE RACKING SPEC. SHEET: SP-3 Aff:�s. IRON RIDGE IronRidge FlashFootTM is an all -in -one solar mounting product for composition shingle roofs that eliminates the need for separate standoffs, flashings, and L-feet. FlashFoot incorporates a number of structural and waterproofing features to securely attach IronRidge Rails to roof structures, while also protecting against water intrusion and weather damage. Load Distribution Plate A solid metal plate below the L-foot e increases the FlashFoot's structural strength and prevents any deformation of the flashing during installation. Certified compliant IAPMO with" and IRC. ES CUPERTINO r> j E3iailding Department FlashFoot TM Installation Overview REVIEWED FOR CODE COMPLIANCE Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking grpprp��nt dill with 1 /4" bit and 1 /2" socket. w Dual Mechanical Seal a At the core of the FlashFoot, a pre -installed rubber bushing forms a dual mechanical seal, with its exterior compressed against the cavity of the L-foot and its interior tightly �F wrapping around the shaft of the lag bolt. lt� 1 Water Shedding Design A wide flashing layer combined with an elevated sealing platform maximizes the FlashFoot's water shedding ability. Locate rafters and snap vertical and horizontal lines to mark locations of flashings. Drill 1 /4" pilot holes, then backfill with an approved sealant. Line up pilot hole with flashing hole and insert lag bolt through bonded washer, L-Foot, and flashing. Tighten lag bolt until fully seated. Testing & Certification Slide flashing, between 1 st and 2nd course, so the top is at least 3/4" above the edge of the 3rd course and the bottom is above the edge of the 1 st course. The FlashFoot is now installed and ready for IronRidge Rails. With provided L-foot fasteners pre - loaded into rails, drop rails into open L-foot slots. FlashFoot is certified for compliance with the International Building Codes (IBC) & International Residential Codes (IRC) by IAPMO-ES. Mechanical testing conformed to the standard for Testing and Analysis of Joist Hangers and Miscellaneous Connectors (EC002-2011), and rain testing conformed to the Underwriters Laboratory Standard for Gas Vents (UL 441-96 Section 25). Douglas Fir, Larch .50 798 Douglas Fir, South .46 705 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 705 Hem, Fir .43 636 Hem, Fir (North) .46 705 Southern Pine .55 921 Spruce, Pine, Fir 42 615 I Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 sources:—oncen Wood count!!, - [uua, more , r . , i. _. no— g , nreau mus oe emaemea in a rarer or Omer soucmmn ma memoir. u, see inu Tor regmrea edge aisrances. 1 RFVICIr1NC 1 11111111 DRAWN BY: LK/AB Gf,f��, IRONRIDGE Simplified Grounding For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. CUPERTINO �8uilding Department (. 0 Integrated Grounding System Installation Overview REVIEWED i FOR Gt-7Dl^ COMPLIANCE .�` Install Roof Attachments Reviewed By:�/—'---- w • Install appropriate roof flashing and/or standoff for roof type. -,•-=� • Attach L-Feet to flashing or standoff. �- Prepare Rail Connections ' • Insert splice into first rail, then secure with Grounding Strap and \ e jself -drilling screw. L+ • Slide second rail over splice, then secure with opposite end of y• -- Grounding Strap and self -drilling screw. �t (Tfl-- I Mount &Ground Rails • Attach rails to L Feet and level rails. Grounding Mid Clamp • Install one Grounding Lug per row of modules. Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and •Connect Grounding Lug to grounding conductor. r' ' the mounting rail to form secure electrical bonds, P, which are repeated throughout the array. Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. " <« ®� w/d► c 2 7 Grounding Strap' " = t s erg. Grounding Straps are used to r bond rail -to -rail connections. _wf They are only required on the �4f i rail with the grounding lug. 4 3 Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. l e� Module Frame Compatibility A Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Clamp has proven robust in grounding 60-cell and 72-cell solar module frames with box construction and a range of anodization thicknesses. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ironridge.corn/irg ## Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) 1 Rr,%Agi mc; 1 11111111 �M `w MMOM IDRAWN BY., LKIAB SMOKE /'CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT-BUILDING DIVISION F CUFF-RTINO 10300 TORRE AVENUE-CUPERTINO,CA 95014-3255 (408)777-3228- FAX(408)777-3333- building(akupertino.org Aldr-6-98 Carhan:?�'I_onoxide: PERMIT CANNOT BE FINALRD AND COMPLETED UNTIL TMS CERTIFICATE HAS BE-EN&aN TO TIMI,BUILDING DIAr1$10.N1 PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarm's are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarm(s)may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the buildhig wiring. As owner of the above-referenced property,11 hereby certify that the alarm(s) referenced above has/have been installed in.accordance with the manufacturers instructions and in compliance with the California Building and Calilfonrda,Residential Codes.The alarms have been tested and are operational, as of the date signed below. t have,read and,ailree,to,comp! withthe:terms and!conditions of this statement KIL I.S ty A 6-P TA ��_ SfTName: ' /Ij .? • "A4 C ...........12 A Smoke and:COforni.d6c revised+0311'8114 t�I SIaUJ 7v S�,a� F1 E WATER-CONSERVING PLUMBING FIXTURES (3 I6 Sa OWNER CERTIFICATE OF-COMPLIANCE 1091 COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPERTIINO 10300 TORRE AVENUE-CUPERTINO.CA 95014-3255 (408) � 777 $•FAX(408)777-3333•bulding(ftuaertino.ora Owner Name C�S�L�.Tl� �, �� Permit No. ''�`�f3i( � $ Address 6, q 9 OLI v�— -I�l1.t.�P �� �° �I 4- , cA�A 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form D& No Go to Question 2. 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form No Go to Question 3- 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. AT No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real.property is built and available for use or occupancy after January 1, 1994. . Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form 1�(Yes My real property is built and available for use or occupancy on or before January 1,1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form. 5. Please check ONE of the following. My property is a single-family residential real property. See Civil Code Section 1101.4. . On and after January 1,2014,building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with coat -conserving plumbing fixtures throughout the-building.On or before January 1,2017,-all non- compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements)- ❑ Myproperty is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing_fixtures throughout the building(regardless of whether properly undergoes alterations or improvements). ❑ Myproperty is a commercial real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing futures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with.water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). 1,as the owner or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. owner or Owner Agent's Signature: `L Date- Upon completing and signing this Certificate,please return it to the Building Division in order to final your building permit. SB407201 S doe revised 08!16115