Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2016-1882
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1882 22555 SALEM AVE CUPERTINO, CA 95014-5648 (342 12 099) SOLARCITY CORPORATION SAN MATEO, CA 94402 OWNER'S NAME: SINGH INDERJEET AND KAUR MANVEEN DATE ISSUED: 05/04/2016 OWNER'S PHONE: 408-228-4439 PHONE NO: (650) 963-4722 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class WARM-AIR HEATING VENTILATING AND AIR-CONDITIONING X BLDG X ELECT PLUMB Lic. #R88tDA— Contractor SOLARCITY CORPORATION Date 12/31/2016 — — MECH X RESIDENTIAL — COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my JOB DESCRIPTION: license is in full force and effect. INSTALLATION (25) ROOFTOP FLUSH MOUNTED SOLAR PANEL (6.5 KW; (N) SUB-PANEL (125 AMP) I hereby affirm under penalty of perjury one of the following two declarations: r. I have and will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. z. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $14000.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances 342 12 099 and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the PERMIT EXPIRES IF WORK IS NOT STARTED City of Cupertino against liabilities, judgments, costs, and expenses which WITHIN 180 DAYS OF PERMIT ISSUANCE OR e uence of the granting of this permit. may accrue again4DECLARRATION Additionally, the and will comply with all non-point 180 DAYS FROM LAST CALLED INSPECTION. source regulations unicipal Code, Section 9.18. Issued by: Phuong Devries Signature Date / I Date: 05/04/2016 O ER-BUILD RE-ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of the All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: installed without first obtaining an inspection, I agree to remove all new materials for 1. I, as owner of the property, or my employees with wages as their sole inspection. compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) Signature of Applicant: z. I, as owner of the property, am exclusively contracting with licensed Date: contractors to construct the project (Sec.7044, Business & Professions Code). ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the z. I have and will maintain Worker's Compensation Insurance, as provided for by California Health & Safety Code, Sections 25505, 25533, and 25534. I will Section 3700 of the Labor Code, for the performance of the work for which this maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the permit is issued. Health & Safety Code, Section 25532(a) should I store or handle hazardous s. I certify that in the performance of the work for which this permit is issued, I material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Qu Management District I shall not employ any person in any manner so as to become subject to the will maintain compliance with the Cupertino Muni I C , Chapter 9.12 and Worker's Compensation laws of California. If, after making this certificate of the Health & Safety Code, Sections 2550 , 2553 nd 25534. exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall as Owner or authorized ages be deemed revoked. Date: J0V1 6 APPLICANT CERTIFICATION CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the performance correct. I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued (Sec. 3097, Civ C.) relating to building construction, and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands ARCHITECT'S DECLARATION and will comply with all non-point source regulations per the Cupertino Municipal I understand my plans shall be used as public records. Code, Section 9.18. Licensed Professional Signature Date CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (403) 777-3333 • building aacuperbno.ora AE PROJECT ADDRESS�j c1 5 55 APN # vC-oC.- OWNER NAME ` '� I %� PHONE c ` D STREET ADDRESS n n Q STAT Zr^� CA )141 FAX CONTACTNAMEMarjan Javanmard PHONE650.477.6430 E-MAILmjavanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR © CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTORNAMESOIarClty Corporation LICENSENUMBER88810A LICENSE TYPE C10 BUS. LIC #28844 COMPANY NAMESOIarCity Corporation E-MAILmjavanmard@solarcity.com FAX STREETADDRESs391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 FHONE650.477.6430 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF " SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ NO PROJECT IN FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS FOELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY): /` TOTAL VALUATION: DESCRIPTION OF WORK Installation (,L-5) rooftop flush mounted solar panel (6.5 ) kW RECEIVED By my signature below, I certify to each of the following: I am the j r/operty o er of authorized agent to act on the p erty o er's behalf. I have read this application and the information I have provided is correct. I have ,ad the fj scription ofWork and verify it is accu e I agree t comply with all applicable local ordinances and state laws relating to building construction. I attilori resentatives of Cupertino to enter the above-ideN property for inspection purposes. Signature of Applicant/Agent: Date: S, a L I SUPPLEMEI�A'L INFORMATION REQUIRED OFFICE USE ONLY ❑ OVER-THE-COUNTER ❑ EXPRESS U u x ❑ STANDARD U ❑ LARGE a ❑ MAJOR PVApp_201 Ldoe revised 03/16/11 ABBREVIATIONS I ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT LICENSE CA # 888104 C-10 MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Cupertino UTILITY: Pacific Gas and Electric Company 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK TO BE DONE TO THE 2013 CALIFORNIA BUILDING CODE, 2013 CALIFORNIA PLUMBING CODE, AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. CONFIDENTIAL - THE INFORMATION HEREIN IOB NUMBER: JB -9507196 0 0 CONTAINED SHALL NOT BE USED FOR THE SITE PLAN BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENT'SORGANIZA THREE LINE DIAGRAM THE SALE ¶AND USEEOF CEPT ITHE O RESPECTIVE NNECTION WITH MODULES (25) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB PVI-3.0—OUTD—S—US—Z—A FLASHING WILL BE PAINTED TO MATCH EXTERIOR INDERJEET SINGH 22555 SALEM AVENUE CUPERTINO, CA 95014 P LANS C CKED r CUMN1UNITY DEV.E.LOPMENT.DEPARTfli1 ©ATE -� BUILDING DIVISION = CU.PERTfNO EST CANNING DEPT A ppo®�E® CUPERTINO This set of plans and specificatiQn_s MIDST be keptata?ie job site during construction. It is unlawful"to make arty changes or alterations on same, or to.devjae therefrom, without approval from the Bu1lding icial: The Stamping of this plan and sDecifirat�nn� cunt i K-,,. be I -" of a BY DA- PEF VICINITY MAP DESCRIPTION: Inderjeet Singh RESIDENCE 6.5 KW PV ARRAY PAGE NAME COVER SHEET CUPERTINO Building Department MiAY 0 3 2016 REVIEWED IFOR CODE COMPLIANCE Reviewed By: W4D___ INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM Cutsheets Attached yKCory r ni �Y REV BY DATE COMMENTS REV A I NAME I DATE I COMMENTS * * * ..r 1. 1%.. - ©l 10 DESIGN: Mike Baba SHEET: REV: DATE PV 1 5/2/2016 * -0 1SolarCity 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F.(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE- THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9507196 0 0 MOUNTING SYSTEM: Coma Mount Tvpe C (25) REC # REC260PEZ INVERTER: ABB# PVI-3.0—OUTD—S—US—Z—A 22555 Salem Avenue INDERJEET SINGH 22555 SALEM AVENUE CUPERTINO, CA 95014 REVIEWED FOR CODE COMPLIA Reviewed BY: TOTAL ARRAY AREA (SF) 453 PITCH: 27 ARRAY PITCH: 27 MPI AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Comp Shingle STORY: 1 S1 PITCH: 27 ARRAY PITCH: 27 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 1 Si PITCH: 27 ARRAY PITCH: 27 MP3 ' AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shinqle STORY. 1 Si LFGFND F —] (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS A DC DC DISCONNECT & WARNING LABELS FTC I AC DISCONNECT & WARNING LABELS F DC JUNCTION/COMBINER BOX & LABELS OD DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE O HEAT PRODUCING VENTS ARE RED r, lk INTERIOR EQUIPMENT IS. DASHED L_J SITE PLAN TOTAL ROOF AREA (SF): 2847 Scale: 3/32" = 1' TOTAL ARRAY AREA IS m 15.92 01' 10' 21' Emilia PERCENT OF TOTAL ROOF AREA DESCRIPTION: DESIGN: Inderjeet Singh RESIDENCE Mike Baba 6.5 KW PV ARRAY PAGE NAME: SITE PLAN SHEET: REV. DATE:- PV ATEPV 2 5/2/2016 N W+ E s ,solarCity. 3055 Clearview Way San Mateo, CA 94402 L•(650) 638-1028 F.(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CUPERTINO f tisi auildlna, L/ 15c"�(I 1Failt fes` ..r'�` 3 rtQ REVIEWED FOR CODE COMPLIA Reviewed BY: TOTAL ARRAY AREA (SF) 453 PITCH: 27 ARRAY PITCH: 27 MPI AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Comp Shingle STORY: 1 S1 PITCH: 27 ARRAY PITCH: 27 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 1 Si PITCH: 27 ARRAY PITCH: 27 MP3 ' AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shinqle STORY. 1 Si LFGFND F —] (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS A DC DC DISCONNECT & WARNING LABELS FTC I AC DISCONNECT & WARNING LABELS F DC JUNCTION/COMBINER BOX & LABELS OD DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE O HEAT PRODUCING VENTS ARE RED r, lk INTERIOR EQUIPMENT IS. DASHED L_J SITE PLAN TOTAL ROOF AREA (SF): 2847 Scale: 3/32" = 1' TOTAL ARRAY AREA IS m 15.92 01' 10' 21' Emilia PERCENT OF TOTAL ROOF AREA DESCRIPTION: DESIGN: Inderjeet Singh RESIDENCE Mike Baba 6.5 KW PV ARRAY PAGE NAME: SITE PLAN SHEET: REV. DATE:- PV ATEPV 2 5/2/2016 N W+ E s ,solarCity. 3055 Clearview Way San Mateo, CA 94402 L•(650) 638-1028 F.(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com SIDE VIEW OF MPI NTS A MP1 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" SEAL PILOT HOLE WITH POLYURETHANE SEALANT. PORTRAIT 48" 20" INSERT FLASHING. RAFTER C.J. 2X6 @ 24" OC 2X6 @16" OC ROOF AZI 90 PITCH 27 STORIES: 1 ARRAY AZI 90 PITCH 27 Comp Shingle - Skip Sheathing (SIDE VIEW OF MP3 NTS C D MP3 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48" 2011 C.J. CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 2x6 @ 24" OC 2x6 @16" OC JOB NUMBER: JB -9507196 MOUNTING SYSTEM: COmD Mount Tvwe C (25) REC # REC260PEZ INVERTER: ABB# PVI-3.0—OUTD—S—US—Z—A ROOF AZI 270 ARRAY AZI 270 Comp Sh 00 PITCH 27 STORIES: 1 PITCH 27 Ile - Skip Sheathing PREMISE OWNER: INDERJEET SINGH 22555 SALEM AVENUE CUPERTINO, CA 95014 CUP?RTINO Bulic,fing department N1 A"If 0 3 2010 'D FOR CODE COMPLIANCE SIDE VIEW 0 F M P2 iewed By: 6 MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" SEAL PILOT HOLE WITH POLYURETHANE SEALANT. PORTRAIT 48" 20" INSERT FLASHING. RAFTER C.J. 2X6 @ 24" OC 2X6 @16" OC ROOF AZI 180 PITCH 27 STORIES: 1 ARRAY AZI 180 PITCH 27 I Comp Shingle - Skip Sheathing PV MODULE 5/16" BOLT WITH FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER S 1 STANDOFF Inderjeet Singh RESIDENCE 6.5 KW PV ARRAY PAGE NAME: STRUCTURAL VIEWS DESIGN: Mike Baba INSTALLATION ORDER (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. SHEER REV: DATE- PV ATEPV 3 5/2/2016 'SolarCit y 3055 Clearview Way San Mateo, CA 94402 T-(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com UPLIFT CALCULATIONS INO ��f�f�1�FtIi )E OC)MPLIANCE CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER:PREMISE JB -9507196 00 OWNER: DESCRIPTION: INDERJEET SINGH Inderjeet Singh RESIDENCE 22555 SALEM AVENUE 6.5 KW PV ARRAY CUPERTINO, CA 95014 PAGE NAME UPLIFT CALCULATIONS 05.02.2016 ° lyste structural Version #56.4 pri ty. Desion Software MEET: REV: DATE: PV 4 5/2/2016 )Project Information ScTab1e'0f :Corrtee>tts Rlsk Category II SolarCh' be' dung" Comp Roof Comp Roof L er's of'Com Roofih . J _ ,270 Rafter:5 adno24" b.0 . _. .; PV System Module Ortentatlon Landscape and Portrait PU Module i ,. ,'...... � .... , .._ PV Module Width 39" Standoff Attachment Hardware Gom Mount T e,C. 6teda�ced Gra trio/:i€6of=LWblsiidw Dads. 4 W Ground Snow Load 0.0 psf ASCE Table 7-1 Roof Snow Over.. PV Modules 0.0 sf ASCE Ed- 7.4-1 Wind Design Code ASCE 7-10 Wind esEgn M, , od ��... �° z.w , 7-7 a k.er- 6 w, �rGailYl�Fully EncEased h)ethods Basic Wind Speed V 1i0 mph Fig. Z§.5 -1A Exposure C�fegary Raof S le ty C Gable Roof, r� fx-,a Section 6 7' f>9 3 R�4fr�f� 5 H _. NleaafRaof tlefoll .. . _. , ? A Effective Wind Area 1 Module A 17.8 sf w r II)7509.7 " Int):lPreSa1GAl)tl0'-ni7n@ffi1int9 Wind Pressure Exposure Kz y 0 85 F sf a Tablte30� 1 N Topographic Factir Kzt Wind Directionalsty Factor Kd 0 85 Section 26 &1 Im ortanee Factat I .. NA..', i .: I Velocity Pressure 9h qh = 0.00256 (Kz) (Kfzt) (Kd) (W! 2) 22.4 psf Ext Pressure Caefficient (Up) GC p (Up) -0.88 Fg 30 4 ZAfBjC SA/B t Ext., PressureXe, cierit' w1t y G Design Wind Pressure. = h GC € uaYion 30.4=L .Mfid Pressure U TNindPressure Down dime 16.0 iisf }C=®irection ` YDirecEibn.3' Max Allowable Standoff Spacing Landscape 72 39' n m�. SNA_ Standoff Configuration' Landsea a Not -Staggered Max StandgffTlbtltary_Area.,.•. T m_m... w .,. _ ..v... ... PV Assembly Dead Load vv' -'PV 3 psi Net Winr1 Uplrft, ae S#andafi( ry.... ,. T. lbs e .. Uplift Capacity of Standoff Tallow 500 lbs ,Sticto=Deiriand Ca a ' l3CR 39 5ti% Max Allowable Standoff Spacing Portrait 48" 66" � h Standoff Configuration Portrait Not -Staggered M.O StarldoffTrlbutaryArea._m ._.M: TrIb__._ mbl PV Assey Dead Load W PV 3 psf Net Wi f1d,Upl►ft_at Standoff _ T�clual___e..._.__. Uplift Capacity of Standoff -allow 500 lbs StandoffDemanti.Ca LI __J [?CR' 94.3la _r INO ��f�f�1�FtIi )E OC)MPLIANCE CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER:PREMISE JB -9507196 00 OWNER: DESCRIPTION: INDERJEET SINGH Inderjeet Singh RESIDENCE 22555 SALEM AVENUE 6.5 KW PV ARRAY CUPERTINO, CA 95014 PAGE NAME UPLIFT CALCULATIONS DESIGN: Mike Baba _- \�,,� A-�� ;S®��r�,�t� ►�� MOUNTING SYSTEM: Comp Mount Type C . ' v1/�. .Gi G MODULES: (25) REC # REC260PEZ 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcitycom MEET: REV: DATE: PV 4 5/2/2016 INVERTER: ABB# PVI-3.0—OUTD—S—US—Z—A GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD AT PANEL WITH IRREVERSIBLE CRIMP Panel Number: SMB20(2-4)SN Meter Number: 1008457595 Inv 1: DC Ungrounded Inv 2: DC Ungrounded INV 1 -(1)ABBPVI-3,0-OUTD-S-US-Z-A A FCI Verter, Zigbee 30DOW, 24OV, ' -(5)REC # REC260PEZ PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled CA # 888104 C-10 Underground Service Entrance INV 2 -(1)ABBPVI-3.O-OUTD-S-US-Z-A 8 96% FCI nverter, Z'igbee 3000W, 24OV, Voc: 37,8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL Multiple Main Breakers (6 or fewer) ADJUST MIN. ACTIVATION VOLTAGES! BRYA Inverter 1 PAR (N) 125A Loaadd Center 9 7 ABB B TL1 PVI-3.0-OUTD-S-US-Z-A (E) LOADS 20A/2P zaov SolarCity Lz 50A/2P -------------------------------------- EGCI DC+ 4 A 1 DC+ VStart = 200V A I I Zi i t 8 z - cec _ _ _ T N DG DG MP 1: 1X12 I EGC---—---------- -—----- - - - - -- --,----- - - E------------ - ----j 1I I T I ' I ADJUST MIN. ACTIVATION VOLTAGES! N I I , . Inverter 2 IND EGCIGEC _ I z 8 ABB PVI-3.0-OUTD-S-US-Z-A 6 ❑ +0 DC+ VStart = 200V DG MP 2: 1x6 i 20A/2P GEC I --- ----� L1 2,-o r--------- I ------------ EGG -------- -------� I L2 DC+ TO 120/240/ I I I I N I DG I 5 3 SINGLE PHASE SINGLEPHASE I L_ L____—___________—___________—_____-___-- -EGCI GEC _-- DC+ �� DGG Dc+ VStart = 200V MP 3: 1X7 EGC--- G�------------- --------- ------------ --F----- -- ----� I 50A/2P (1 )Conduit Kit; 3/4' EMT �� UPERTINO TO (E) LOADS �.;:..:. a -+ � flag Department nt ��. ' T''d:y vvAli:,1 1 G�1 61�n� f pp g� t- N4e'032016 REVIEWED FOR CODE COMPLIANCE Voc* = MAX VOC AT MIN TEMP Reviewed By: Ol (2 )Bumdy $ BIT2f0 Multi- able Connector, 2 Port B (1) CUTLER-HAMMER # BR220 Breaker, 20A 2P, 2 Spaces PV BACKFEED BREAKER Q� A (1) SolarCit�r ��pp 4 STRING JUNCTION BOX D� 2.2 STRMGS, UNFUSED, GROUNDED - (1)Gro qd Rod 5%B x B, Copper -(I CUTLER-HAMM BR220 Breaker, 20A%2P, 2 Spaces PV BACKFEED BREAKER -(1)CUTLER-HAMMER # BR250 Breaker, 50A 2P, 2 Spaces - (1) BLYad Center, Load 0/24OV, NEMA 3R 11L2,5A, 12 1 AWG #8, THWN-2, Black - 1 AWG #B, iHWN-2, Red (WFRL) O (1)AWG #8, THWN-2, Red -0) Conduit Kit; 3/4' EMT O (1 AWG #10, THWN-2, Black (1) AWG #10, THWN-2, Red ® 1)AWG #10, THWN-2, Black Voc* = 494.02VDC Isc = 9.01 ADC (1) AWG #10, THWN-2, Red Vmp = 368.4 VDC Imp= 8,5 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* = 494.02VDC Isc = 9.01 ADC O (1) AWG #10, Solid Bare Copper EGC Vmp = 368.4 VDC Imp= 8.5 ADC (1)AWG 18, THWN-2, White Neutral Vmp =240 VAC Imp=N/A AAC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC IMP= 14.5 AAC (1 AWG 10, THHN WN-2, Green EGC - 1)Conduit Kit; 3 4' .. #...... .............. (.... t. Kl /4 EMT ....... -•(1) AWG j8,. TITWN-2,. Green .. EGC ....- (1) AWG. #8, .111WN-2,, Black... (WERE).. ....... -.(1) AWG #8,, iFIWN-2,. Green .. �(1) AWG #10, THWN-2, Black EGC/GEC .- (1) Conduit. Kit;. 3 .4" .EMT..... • _ .. 1 . (1) AWG #10, THWN-2, Black Voc* = 288.1 S VDC (1)AWG 10, THWN-2, Red Vm = 214.9 VDC p ff Isc = 9.01 ADC p Im = 8.5 ADC(1)AWG ( 2) AWG #10, PV Wire, 600V, Black Voc* = 247.01 VDC Isc = 9.. ADC O � (1) AWG #10, Solid Bare Copper EGC Vmp =184.2 VDC Imp= 8.5 ADC # 10, THWN-2, Red AD, THHN/THWN72, Green EGC (!)AN# (1)AWG #10, THWN-2, White 7.0 )AWG #8,, it IWN-2,. Green ..EGC/GEC.- NEUTRAL Vmp =240 VAC Imp=14.5 AAC . (1) Conduit. Kit;, 3/4 .EMT..... ....... ©� . (1)AWG #10, THWW-2, Black Voc* = 247.01 VDC (1) AWG #10, THWN-2, Red Vmp =184.2 VDC Isc = 9.01 ADC Imp= 8.5 ADC (Y)AWG #10, PV Wire, 600V, Black Voc* = 288.18 VDC Isc = 9.01 ADC Off(1)AWG #10, Solid Bare Capper EGC Vmp = 214.9 VDC Imp= 8.5 ADC ........(1) AWG #10, iliHN/111WN-2, .Green EGC .................................... ............................................................... . CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER:PREMISE JB-9507196 � � OWNER: INDERJEET SINGH 22555 SALEM AVENUE DESCRIPTION: Inderjeet Singh RESIDENCE DESIGN; Mike Baba �, � '� SolarCit y. F MOUNTING SYSTEM: F / NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C 6.5 KW PV ARRAY CUPERTINO, CA 95014 ��� MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH v 3055 aearylew Way THE SALE AND USE OF THE RESPECTIVE (25) REC # REC260PEZ SHEET, REV: DATE PV 5 5/2/2016 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME THREE LINE DIAGRAM San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)-SOL-CITY (765-2489) www.solarcity.com INVERTER: ABB# PVI-3.0-OUTD-S-US-Z-A Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED Label Location: (POI) Per Code:; _ !� CEC 690.54• CEC 690.17 -'ff ..t F3U"d'nc' Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 REVIEWED FOR CODE COMPLIANCE Reviewed By: (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ►o�4j 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �, p s San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set �►�rn► 1T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WTH THE SALE AND USE OF THE RESPECTIVE /��solarC ' � (888)-SOL-CITY(765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o \ ,SoiarCity ZepSolar Next -Level PV Mounting Technology \"�,:ItSoiarCity Zep Solar Next -Level PV Mounting Technology Zep System for composition shingle roofs QOOMPgT'B SFA / 0� �eMPAt� QLISTED zepsolar.com Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for. Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1890-001 Rev Date last exported: November 13, 2015 2:23 PM Components zepsolar.com Leveling Foot Part No. 850-1172 ETL listed to UL467 Comp Mount Part No. 850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 Interlock Part No. 850-1388 Listed to UL 2703 roof ----------- Ground 4 Ground Zep V2 Part No. 850-1511 Listed to UL 467 and UL 2703 DC Wire Clip Part No. 850-1448 Listed to UL 1565 I I! 0 ttc l� �j r a t ICI?lent REVIEWED FOR CODE COMPLIANCE Array Skirt, Grip, End Caps Reviewed By. =`v- - Part Nos. 850-0113, 850-1421, O 850-1460, 850-1467 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document# 800-1890-001 Rev A Date last exported: November 13, 2015 2:23 PM This family of single-phase string The high-speed MPPT offers real - inverters complements the typical time power tracking and improved number of rooftop solar panels energy harvesting. i enabling home -owners to get the most The flat efficiency curve ensures high efficient energy harvesting for the size efficiency at all output levels allowing of the property. a consistent and stable performance logger). across the entire input voltage and This inverter offers a dual input output power range. section that processes two strings The transformerless operation gives the with independent Multiple Power Point highest efficiency of up to 97.0%. Tracking (MPPT). The wide input voltage range makes This is especially useful for rooftop the inverter suitable to low power installations with two different installations with reduced string size. orientations from two sub -arrays This rugged outdoor inverter has been oriented in different directions. (For designed to be a completely sealed example: East and West) unit able to withstand the harshest The dual input sections with environmental conditions. independent MPPT enable a more i optimal energy harvesting condition. 14.5 Highlights: — Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Power .. • productivity ,iii � � se for a better world' A , 11 g. Additional highlights: 1101 2W......._0/3W...i.....2W........... OPRi- s; — RS -485 communication interface bpu[- i..0/3VJ...i.....2W 1101 Adjustable voltage range (Vmin-Vmax) M (for connection to laptop or data 244- ......._0/3W...[...._ZW...... 183 211 244- j 183 - i 211 244- - logger). .... 244 2 ....:........... — Integrated Arc Fault Detection and 304V ...... 22 8.......:_.,264V 304V [ 228V 264V i 304V i 228V :r Interruption (-A Version).` Grid frequency...................................................................................................................................................... .... ..., .... ......... ...... 60Hz ...... Y c ' Imo# r xZTm �s�,'+e; Adjustable grid frequency..ran..ge.............................................................................................................................................57-60.5Hz ................................................................................................................................................................... i 14.5 14.5 i 12.0 € 17.2 i 16.0 € 16.0 '. 16.0....: 1.-6.-..0..--:---1-.6.-.-0- 20.0...: 20.0 20.0 .................................................................................................:....ARKS....:.... ARMS....:.... ARM,....:.... ARMS....:....ARMS.-..:....AR0.S.._:.... ARMS... :..._ARKS....:.... ARm. ....... _ ARKS....:.... 1` Technical data and types Power factor ......... . ................................................................................................[................................................................................................................................................................................................................................................ Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Mechanical specifications = Nominal output power ................................................................................................................................... 3000W 360OW 3W0 380OW 420OW Maximum output power wattage 3000 3300' i 3300' i 3600 4000' i 40001 i 3300 4200' i 42001 4,2'0'-0--;-46001 4600' W W W ...................:.......................................................... W W W W W W €................................................................................................................... W W W Rated grid AC voltage 208V i 240V i 277V 208V i 240V 277V 208V i 240V [ 277V 208V i 240V 277V Input,side (DC) " ; Reverse polarity protection ................:.... Over Number of independent MPPT channels 2. 2 2 2 Maximum usable power for each channel ............................................................................................................................................................................................................................................................................................ 2000W .......................................... 3000W 3000W 3000W Absolute maximum vclta0e (Vmax) 600V Start-up voltage (Vstart) ................................__ .......................................................... _...............................................................................-..... .................................. .............................................................................................. 200V (adj. 120-350V) FuII power MPPT voltage range 160-530V 120-530V 140-530V 140-530V.................. Operating MPPT voltage range .........................................................i ..... ............................................................... 0.7 x Vstart - 580V (>=90V) . Maximum current (Idcmax) for both MPPT in ... ......... ...... ..................... ..parallel ...........................................................................................i........................................................... 20A i............................ 32A 32A 32A Maximum usable current..p..er channel 10A i 16A .................... 16A.................... 1.SA......................... ......................................................................................................................................... Maximum short circuit current limit per ...... 25A ............................................................ . channel:........................... 12.5A 20.OA 20.OA 20.OA ....-........................................................................................ Number of wire landing terminals per channel ......................................................................................................................................................................................................................................................... .................................... ...........................................:..........................................................i'........................................................... 2 pairs Array wiring termination q� Terminal block, pressure clamp. AWG10-AWG4 Grid connection type ............................................................................... .............................. 1101 2W......._0/3W...i.....2W........... OPRi- i iiur iun opu[- i iwr 1W apuo- ivy iun !! �W......_0/3W...[.....2W......i...._2W bpu[- i..0/3VJ...i.....2W 1101 Adjustable voltage range (Vmin-Vmax) M 183 - 244- ......._0/3W...[...._ZW...... 183 211 244- j 183 - i 211 244- - i 211 .... 244 2 ....:........... 211 304V ...... 22 8.......:_.,264V 304V [ 228V 264V i 304V i 228V 264V i 304V..., Grid frequency...................................................................................................................................................... .... ..., .... ......... ...... 60Hz ...... .. Adjustable grid frequency..ran..ge.............................................................................................................................................57-60.5Hz ................................................................................................................................................................... Maximum current (lay, n.) 14.5 14.5 i 12.0 € 17.2 i 16.0 € 16.0 '. 16.0....: 1.-6.-..0..--:---1-.6.-.-0- 20.0...: 20.0 20.0 .................................................................................................:....ARKS....:.... ARMS....:.... ARM,....:.... ARMS....:....ARMS.-..:....AR0.S.._:.... ARMS... :..._ARKS....:.... ARm. ....... _ ARKS....:.... ARMS....:.... ARMS..... Power factor ......... . ................................................................................................[................................................................................................................................................................................................................................................ > 0.995 Total harmonic distortion at rated power < 2% Grid wiring termination type ...... ..... ....... ....... .. ....... Terminal block Pressure clamp AWG1Y5%iWCiQ - �I Input.protection devices r[ b ._ Reverse polarity protection ................:.... Over Yes r.... - ". rj (J (^�.. rr.. I `i� id, f.) ar f1 f ' voltage protection type ....................................... PV array round fault detection ................ ...................--_....................Var..... Pre ._2 for each channel.. _x . _: ... start-up Riso and Dynamic GFDI (require #666 r g`arrays ...................'� Output protection devices t ,• 2s Anti-islanding protection Meets UL 1741/IEEE1547 require ents .... ttri� Over -voltage protection type ....... ............................................ ... ......... .................:............................................9........................... Varistor, 2 (L, Le/Li G) M a t.. Maximum AC OCPD Ratin 20A 20A i 15A ..... .¢ ... 25A ; 20A ;20A ;20A 20A 20A 25A ........................ 25A ...... 25A Efficiency= -'o :o) -tip f3" F OR' C' COMPLIANCE Maximum efficiency 96.9/0 o 97/0 97/ q� tnwronmemai Ambient air operating temperature range -1 W to +140°F -with deratina above 122°F 1500Cl 1. Capability enabled at nominal AC voltage and with sufficient DC power available. 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD < ou eo 1Hi cen m 6560 ft 12000 ml 55.55 ±0.1 1.33 34.02 ._..,. .. ....._. ..47,24 _ 0.47 Q F I W:;...._.......__.. and ..ALL_......_..........._...,. .. .... .. , _ i_.. ty All measurements In inches b`REC26OPEZ Nominal Power-PMPP (Wp) 260 Watt Class Sorting-(Wp) -/-5 Nominal PowerVoltage-VMPP (V) 30.7 Nominal Power Current- IMpp (A) 8.50 Open Circuit Voltage -Voc (V) 37.8 Short Circuit Current- Isc (A) 9.01 Panel Efficiency (%) 15.8 The electrical characteristics are within +/-10%of the Indicated values of I c, Vvc and P_ at standard Test conditions (STC). Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W%m2, cell temperature 777 (25"C)). At low irradiance of 200 w/m' (AM 1.5 & cell temperature 77°F (25°C)) at least 97% of the STC panel efficiency will be achieved. a f• Nominal Power-PMPP (Wp) 197 Nominal Power Voltage-VMpp (V) 29.0 Nominal Power Current--IMpp (A) 6.81 Open Circuit Voltage- Vat (V) 3S.7 Short Circuit Current- Isc (A) 7.24 Nominal operating cell temperature NOCT (800 W/m', AM 1.5, windspeed 1 m/s, ambient temperature 68°F (20°C). s 10 year product warranty. cul us 25 year linear power output warranty LISTED (max. degression in performance of 0.7%p.a.). UL 1703, Fire rating: Type 1, Class C REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better°1 meet the world's growing energy needs. RECis headquarteredin Norwayand listed an the Oslo Stock Exchange (ticker: RECSOL). Ourl,600 REC employees worldwide generated revenues of USD 647 million in 2013. www.re�,,c�roup.com 210116 REVIEWED FOR CODE COMPUA/ Reviewed By: CE \: 0 'SolarCity ZepSolar DWV Debris Guard for composition shingle roofs Next -Level PV Mounting Technology DWV Debris Guard Construction Detail Debris Guard, close up DWV Debris Guard is made of rugged 26 gauge galvanized steel. Prevent blockages and keep vents open with the DWV Debris Guard. �Q,,pMPgT��` 41 8'Jildirir 00pUFment / Protects against: m� -eMPPt� Leaves Rain • Pine needles Insects • Snow Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. REVIEWED FOR CODE COMPLIANCE Reviewed By: zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1677-001 Rev A Date last exported: April 3, 2015 4:04 PM CUPERTINO 8'Jildirir 00pUFment REVIEWED FOR CODE COMPLIANCE Reviewed By: zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1677-001 Rev A Date last exported: April 3, 2015 4:04 PM