15090011CITY OF CUPERTINO BUILDING PERMIT
BUILDINGADDRESS:
CONTRACTOR:
PERMIT NO: 15090011
1048 COLONY HILLS IN CUPERTINO CA 95014 (359 28 040)
A & O
CONSTRUCTION
SAN JOSE, CA 95035
OWNER'S NAME: ANUMALA MOHNISH AND SREELAXMI
DATE ISSUED: 05/09/2016
OWNER'S PHONE:
PHONE NO: (408) 687-2615
LICENSED CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO:
License Class GENERAL BUILDING CONTRACTOR tic. # 5105
Contractor A& O CONSTRUCTION Date 08/31/2016
_BLDG _ELECT _PLUMB
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
MECH _ RESIDENTIAL _ COMMERCIAL
_
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
JOB DESCRIPTION:
CONSTRUCT ONE STORY ADDITION (707 SQ FT); KITCHEN
I hereby affirm under penalty of perjury one of the following two declarations:
REMODEL (216 SQ FT); REMODEL OTHER (298 SQ FT).
x. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the 'DEF
#1 - TRUSS CALCS - ISSUED 7/26/16
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
Sq. Ft Floor Area:
Valuation: $110000.00
APPLICANT CERTIFICATION
certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
APN Number:
Occupancy Type:
and state laws relating to building construction, and hereby authorize
359 28 040
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
PERMIT EXPIRES IF WORK IS NOT STARTED
may accrue against said City in consequence of the granting of this permit.
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
Additionally, the applicant understands and will comply with all non -point
source regulations per the Cupertino Municipal Code, Section 9.18.
180 DAYS FROM LAST PECTION.
Signature// . < 3'���%t% Date07/26/1S
Issued by: MELISSA N
Date: 05/09/2016
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of the
RE -ROOFS:
following two reasons:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
1. I, as owner of the property, or my employees with wages as their sole
installed without first obtaining an inspection, I agree to remove all new materials for
compensation, will do the work, and the structure is not intended or offered for
inspection.
sale (Sec.7044, Business & Professions Code)
2. I, as owner of the property, am exclusively contracting with licensed
Signature of Applicant:
contractors to construct the project (Sec.7044, Business & Professions Code).
Date: 07/26/16
I hereby affirm under penalty of perjury one of the following three declarations:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
i. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
HAZARDOUS MATERIALS DISCLOSURE
2. I have and will maintain Worker's Compensation Insurance, as provided for by
I have read the hazardous materials requirements under Chapter 6.95 of the
Section 3700 of the Labor Code, for the performance of the work for which this
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
permit is issued.
maintain: compliance with the Cupertino Municipal Code, Chapter 9.12 and the
s. I certify that in the performance of the work for which this permit is issued, I
Health & Safety Code, Section 25532(a) should I store or handle hazardous
shall not employ any person in any manner so as to become subject to the
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
Worker's Compensation laws of California. If, after making this certificate of
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
exemption, I become subject to the Worker's Compensation provisions of the
the Health & Safety Code, Sections 25505, 25533, and 25534.
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
Owner or authorized agent:
APPLICANT CERTIFICATION -
Date: 07/26/16
1 certify that I have read this application and state that the above information is
CONSTRUCTION LENDING AGENCY
correct. I agree to comply with all city and county ordinances and state laws
I hereby affirm that there is a construction lending agency for the performance
relating to building construction, and hereby authorize representatives of this city
Of work's for which this permit is issued (Sec. 3097, Civ C.)
to enter upon the above mentioned property for inspection purposes. (We) agree
Lender's Name
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in,
Lender's Address
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
ARCHITECT'S DECLARATION
Code, Section 9.18.
1 understand my plans shall be used as public records.
Licensed
Signature Date 07/26/16
Professional I
CITY OF CUPERTINO BUILDING PERMIT
BUHMINGADDRESS- CONTRACTOR: PERMIT NO: 15090011
1048 COLONY HILLS LN CUPERTINO CA 95014 (359 28 040) A & O
CONSTRUCTION
SAN JOSE, CA 95035
OWNER'S NAME: ANUMALA MOHNISH AND SREELAXMI
OWNER'S PHONE: 978-486-4643
LICENSED CONTRACTOR'S DECLARATION
License Class j} Lic. #951051
Contractor A& O CONSTRUCTION Date 08/31/2016
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is In full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
t. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
z. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
and state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
may accrue against said City in consequence of the granting of this permit.
Additionally, the applicant underAtands and will comply with all non -point
source regulations pefhfleZ'tino Municipal Code, Section 9.18.
00M=1 Date .
DATE ISSUED: 05/09/2016
PHONE NO: (408) 687-2615
BUILDING PERMIT INFO:
BLDG —ELECT _ PLUMB
MECH _ RESIDENTIAL _ COMMERCIAL
JOB DESCRIPTION:
CONSTRUCT ONE STORY ADDPI'ION (707 SQ FT); KITCHEN
REMODEL (216 SQ FT); REMODEL OTHER (298 SQ FT).
Sq. Ft Floor Area: I Valuation: $110000.00
"N Number: Occupancy Type:
359 28 040
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS FROM LAST CALLED INSPECTION.
Issued by: Alex Vallelung0
4kr4lo'
narP. n
5m4nm F
I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-
ROOFS:
following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is
t. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for
compensation, will do the work, and the structure is not intended or offered for inspection.
sale (Sec.7044, Business & Professions Code)
z. I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec.7044, Business & Professions Code).
I hereby affirm under penalty of perjury one of the following three declarations:
t. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
z. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
3. I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the
Worker's Compensation laws of California. If, after making this certificate of
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
relating to building construction, and hereby authorize representatives of this city
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
Code, Section 9.18.
Signature Date 5/9/2016
Signature of Applicant:
Date: 5/9/2016
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
will maintain compliance with the Cupertino Munici ial Code, Chapter 9.12 and
the Health & Safety Code, Secti 533, and 25534.
Owner or authorized agent: U �A
Date: 5/9/2016
I hereby affirm that there is a construction lending agency for the performance
of work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Licensed
Professional
CUPERTIN0
CONS i RUCCaT VISION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 �, /
(408) 777-3228 • FAX (408) 777-3333 • buildino(a.cuDertino.org /
NEW CONSTRUCTION ❑ ADDITION
❑ ALTERATION i TI EV%ISION I EFERRED ORIGINAL PERAZIT 9
PROJECT ADDRESS
I r
OWNER NAME
PHONE
S E-DLAIL
STREET ADDRESS I CITY, STATE, ZIP
FAX
CON'T.ACT NAME � I PHONE
STREET ADDRESS
CITY, STATE, ZIP
FAX
C
❑ OANER ❑ OW1.ER-BL-IIDER ❑ OWNERAGE.N'T ❑ CO1vTRACT0R ❑ CON77RACTORAGENT ❑ ARCHITECT ❑ ENGPMM ❑ DEVELOPER ❑ T -:A -,T
CONTRACTOR -NAME LICENSE NUMBER
LICENSE TYPE
BUS. LIC R
CO"\Y TAME
E44AIL
FAX
44YV
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ARCHITECTIENGLN'EER NAME LICENSE NUMBER
BUS. LIC
COMPANY NAME
E-? WL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
DESCRIPTION OF WORK ,
tk
EXISTiVG USE PROPOSED USE CONSTR TYPE
R STORIES
USE TYPE OCC,
SQ.FT.
VALUATION (S)
EXISTG
NEW FLOOR
DEXIO
TOTAL
AREA
AREA
ARE4
NET AREA
BATHROOM
KrrCHEl.
OTHER
REMODELAREA
REMODEL AREA
REMODEL AREA
PORCH AREA
DECK AREA
TOTAL DECKPORCH AREA
GARAGE AREA: DETACH
❑ ATTACH
DWELLPJG UNITS:
IS A SECOND L`NIT ❑ YES
SECOND STORY ❑ YES
BELNG ADDED? ❑ NO
ADDITION? ❑ NO
_
PRE•APPLICATION ❑ 1'ES 71 ES, PROVIDE COPY OF
IS THE BLDG AN 11119
zf TOTAL VALUATION:
PL4\T:G
I
N"L;,
By my signature below, I certify to each of the following: I am the property owner or authorize a. o t&Z'Ne property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of)Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize repres tatives of Cupertino to enter the above -Id ntified property for inspection purposes.
Si -nature of Applicant/Agent:
Date:
SUPPLEI` AIIvrFORl`4ATION RE D
�
New SFD or Multifamily dwellings: Apply for demolition pennit for
existing buildins(s). Demolition permit is required prior to issuance of building
permit for new building.
❑ EGRESS
KM.
I, ' NNNINc I I, :E,�
�-
r
Bldgs: Provide a completed Hazardous Materials Disclosure
`❑� STA\D , .'
_Commercial
Torn if any Hazardous >`4aterials are being used as part of this project.
❑
Copy of Planning Approval Letter or Meeting with Planning prior to�tR
LARCL1
'fl
r T,- P; I
_
submittal of Building Permit application.
z�r
-LJ KR
INSk�3x. >.w ,.�:�.
EN1'IRO\'�TE1T4L 1~E.SL--Ii
B1dgApp_2011.doc revised 06/21111
[Smoot j
CONSTRUCTION PERMIT APPLICATION
Val COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE CUPERTINO, CA 95014-3255 g j
(408) 777-3228 • FAX (408) 777-3333 • buildingCcDcupertino.org 1
CUPERTINO:
❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI 2_REVISIO // bEFERRE ' ORIGINAL PERMIT #
PROJECT ADDRESS p _ APN
OWNER NAME PHONE - E-MAIL\ c on) L
STREET ADDRESS CITY, STATE, ZIP FAX
CONTACT NAMEL� r PHONE E-MAIL
211 k L r,
AIAu010d.a 91
STREET ADDRESS CITY, STATE, ZIP FAX
S l YVL C o
❑ OWNER OWNER-BunDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑' ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME LICENSE NUMBER 115 (O5 / LICENTSE TYPE BUS. LIC #
COMPANY NAME E-MAIL _ FAX
i "Vneo
STREET ADDRESS i CITY, STATE, ZIP PHONE
ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC #
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY, STATE, ZIP PHONE
DESCRIPTION OF WORK ,I" T L 4
EXISTING USE PROPOSED USE CONSTR. TYPE
# STORIES
I
USE
TYPE
OCC.
SQ.FT.
VALUATION ($)
EXISTG
NEW FLOOR
DEMO
TOTAL
AREA
AREA
AREA
NETAREA
-
BATHROOM KITCHEN
OTHER
REMODELAREA REMODEL AREA
REMODELAREA
PORCH AREA
DECK AREA
TOTAL DECKTORCH AREA
GARAGE AREA: DETACH
ATTACH
9DWELLII.TG.UNITS:
IS A SECOND UNIT ❑YES
SECONDSTORY ❑YES
'-
BEING ADDED? ❑ NO
ADDITION? ❑NO
PRE -APPLICATION ❑.YES IF YES, PROVIDE COPY OF
IS THE BLDG AN ❑ YES
; RE. IV
TOTAL VALUATION:
PLANNING APPL # ❑ 1\10. PLANNING APPROVAL LETTER
EICHLER HOME? ❑ NO
By my signature below, I certify to each of the following: I am the property owner or authorized agent ta act on e property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified roperty for inspection purposes.
Signature ofApplicant/Agent: Date:
SUPPLEMENTORMATiON REQU
P
PLAL\ CHECKTIPE
ROITT ING SLIP ,
o� ER THE eour TER n
f�1 BUILDING PI Atvrlt> vlEw g
New SFD or Multifamily dwellings: Apply for demolition permit for
_
existing building(s). Demolition permit is required prior to issuance of buildmQ
b
5Si t
permit for new building.
EXTRESS_' y
PLAl1NINGPLAN REv3EP4
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
❑ sTANDARD
❑arIIBLIc�voRxs
_
form if any Hazardous Materials are being used as part of this project.
El
❑FIRE
LARGE
DEPT
Copy of Planning Approval Letter or Meeting with Planning prior to
I+3Aro
❑==sANrrARX sEa3�R DISTRICT �
_
submittal of Building Permit application.
B1dgApp_2011.doC revised 06121111
CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS; . ' ,
CONTRACTOR:
PERMIT NO: 15090011
1048 COLONY BILLS LN CUPERTINO CA 95014 (359 28 040)
A & O
CONSTRUCTION
SAN JOSE, CA 95035
OWNER'S NAME: ANUMALA MOHNISH AND SREELAXNII
DATE ISSUED: 05/09/2016
OWNER'S PHONE: 978-486-4643
PRONE NO: (408) 687-2615
LICENSED CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO:
License Class B Lie. #951051
Contractor A& O CONSTRUCTION Date 08/31/2016
—BLDG —ELECT _ PLUMB
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing.
— MECH RESIDENTIAL— COMMERCIAL
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
JOB DESCRIPTION:
CONSTRUCT ONE STORY ADDITION (707 SQ FT); KITCHEN
I hereby affirm under penalty of perjury one of the following two declarations:
REMODEL (216 SQ FT); REMODEL OTHER (298 SQ FT).
1. 1 have and willmaintaina certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
(�'2J I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
Sq. Ft Floor Area:
Valuation: $110000.00
permit is issued.
APPLICANT CERTIFICATION
certify that I have read this application and state that the above
information is correct. t agree to comply with all city and county ordinances
APN Number:
Occupancy Type:
and state laws relating to building construction, and hereby authorize
359 28 040
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
PERMIT EXPIRES IF WORK IS NOT STARTED
may accrue against said City in consequence of the granting of this permit.
WITHIN 180 DAYS OF PERMIT' ISSUANCE OR
Additionally, the applicant under tands and will comply with all non -point
source regulations pe a C71ino Municipal Code, Section 9,18.
180 DAYS FROM LAST CALLED INSPECTION.
_Signature--, �.%� bA ` Date 5L9L2016
Issued by: Alex Vallclunea
4/1
OVVINER ER DECL ION
Date: 05/09/2016
14
I hereby affirm that I am exempt from the Contractor's License Law for one of the
-
following two reasons:
All roofs shall be inspected prior to E
ny roofing material being installed. If a roof is
1. 1, as owner of the property, or my employees with wages as their sole
installed without first obtaining an in
pection, I agree to remove all new materials for
compensation, will do the work, and the structure is not intended or offered for
inspection.
sale (See.7044, Business & Professions Code)
2. 1, as owner of the property, am exclusively contracting with licensed
Signature of Applicant:
contractors to construct the project (Sce.7044, Business & Professions Code),
Date: 5/9/2016
I hereby affirm under penalty of perjury one of the following three declarations:
ALL ROOF COVERINGS
TO BE CLASS "A" OR BETTER
1. 1 have and will maintain a Certificate of Consent to self -insure for Worker's
-
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
HAZARDOUS MATERIALS
DISCLOSURE
2. 1 have and will maintain Worker's Compensation Insurance, as provided for by
I have read the hazardous materials
requirements under Chapter 6.95 of the
Section 3700 of the Labor Code, for the performance of the work for which this
California Health & Safety Code,
Sections 25505, 25533, and 25534. I will
permit is issued.
maintain compliance with the Cup
rtino Municipal Code, Chapter 9.12 and the
3. I certify that in the performance of the work for which this permit is issued, I
Health & Safety Code, Section 2
532(a) should I store or handle hazardous
shall not employ any person in any manner so as to become subject to the
material. Additionally, should I us
air contaminants as defined by the
equipment or devices which emit hazardous
Bay Area Air Quality Management District I
Worker's Compensation laws of California. If, after making this certificate of
will maintain compliance with the
upertino Munici al Code, Chapter 9.12 and
exemption, I become subject to the Worker's Compensation provisions of the
the Health & Safety Cod
, Sec ti and 25534.
Labor Code, I must forthwith comply with such provisions or this permit shall
1533,
be deemed revoked
Owner=o► authorized agents
f
APPLICANT CERTIFICATION
Date:/5 9/2016
certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
CONS TION
I hereby affirm that there is a cons
E
ruction lending agency for the performance
relating to building construction, and hereby authorize representatives of this city
of work's for which this permit is issued
(Sec. 3097, Civ C.)
to enter upon the above mentioned property for inspection purposes. (We) agree
Lender's Name
to save indemnify and keep harmless the City of Cupertino against liabilities,
Lender's Address
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
AR HI
T S DECLARATION
and will comply with all non -point source regulations per the Cupertino Municipal
u
I understand my plans shall be used
as public records.
Code, Section 9.18.
Licensed
Signature Date 5/9/2016
Professional
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
CUP1_RTlNt3 (408) 777-3228 • FAX (408) 777-3333 • building o)cupertino.org/ � o
❑ NEW CONSTRUCTION tj ADDITION ❑ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT #
PROJECT ADDRESS
APN # 13 f
OWNERNAME AN 0M
PHONE 7 � / ,`F 3
tl
ry
E PI VI i S —0 nu MGL`a � a; oAe C�} v
STREET ADDRESS
1e z elm (i SLS 9
CITY, STATE, ZIPFAX
�U� R?i
CITY OF CUPERTINO
FEE ESTIMATOR - BUILDING DIVISIO
ADDRESS: 1048 COLONY HILLS LN
FEE
DATE: .09101/2015
REVIEWED
BY: SEAN
APN:
BP#:
F 216-1 s.f.
$645.0.0
*VALUATION:
$,110;0007-7,
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE:
Addition
PRIMARY
USE: SFD or Duplex
2nd Unit? Yes � No
'
OTC. O Yes ®No
PE
PERMIT
TAMATION
TYPE: 1 R3SFDADD
WORK '
CONSTRUCT ONE STORY ADDITION 707 SQ FT • KITCHEN REMOD
L 216 SQ FT); REMODEL
SCOPE
OTHER (298 SQ FT).
hrs
$0.00
TYPE OF FLR AREA
OCCUPANCY TYPE: CONSTR. s.f. PC FEES PC FE ID BP FEES BP FEE ID
r
R-3 (Custom) 11-B,111-B,IV,V-B 707654,00i IR3PL CK $1,666.00 IR37NSP
TOTALS: 1 707 1$2,654.000 $1,666.001--
Mech.
1,666 00
Mech. Plan ('heck Pluillb. Plan Checti plea:, I lan Cheep
F:ti9L>rta. Z'eraa7it Fee:
Plkarnh. Permit Fee: liiec. Permit` Fee:
(.Xher ,ilesla. Insp.E]_L__ Other Plvnib Ip. Ofhei, kc. lnsll>.
44ech. InspPee: I Phunb. Insp. Fee: fI ec. I sly. Fee
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, re, Sanitary Sewer District, School
District. ate.). These fees are ha.ced an the nreliminary information available and are only an estimat Contact the DeDt for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/13)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$2,654.00
F 216-1 s.f.
$645.0.0
Remode 1, Kitchen (<=300 sf)
IREMRESKIT
Suppl. PC Fee: (j) Reg. 0 OT
0.0hrs
$0.00
PME Plan Check:
$0.00
F-2-9-8-1 s.£
_
$431.QQ
Remode 1, Other
IREMRESOTH
Permit Fee:
$1,666.00
Suppl. Insp. Feer Reg. 0 OT
0,0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
C'onsfruetion 1 av:
Administrative Fee:
E)
Work Without Permit? 0 Yes No
$0.00
Advanced Planning Fee: IPLLONGR
$98.98
Selec a Non -Residential
Building or Structure
0'
�
Travel Doc'umentation Fees.
Strong Motion Fee: IBSEISMICR
$14.30
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$5:00„
SUBTDTAES
$4,438.28
$1,076.00
5,514.28
Revised: 07/02/2015
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Residence
1048 Colony Hills Ln.
Cupertino, CA 95014
Project Designer:
J B Construction
1484 Ramon Drive
Sunnyvale, CA 94087
408-738-9581
Report Prepared by:
NIIISIQN
Hector Carbajal
Economy Title 24
6055 E. Washington Blvd. Ste. 445
Commerce, CA 90040
626-549-1379
RECEIVED
3
By
GUPEl R INO
Building Department
OCT 1120%
REVIEWED FOR CODE COMPLIANCE
Job Number: ReviOWed By: J �"1
R-001781
Date:
10/12/2016
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
IThis program developed by EnergySoft, LLC — www.energysoft.com.
L. EnergyPro 6.7 by EnergySort User Number.• 6884 ID: R-001781
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 12
Form MF -1 R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
Zone Load Summary 18
Room Load Summary 19
EneravPro 6.7 by EneravSoft I�h w ,nay ID: R-001781 User Number: 6684
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Calculation Description: Title 24 Analysis Input File Name: R-001781.xml
CFI R -PRF -01
Page 1 of 9
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Residence
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 1048 Colony Hills Ln.
Compliance Margin
Percent Improvement
04
City Cupertino
05
Standards Version Compliance 2015
06
Zip Code 95014
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ4
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 270
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 2648
15
Number of Zones 2
16
Slab Area (ft2) 0
17
Number of Stories 1
18
Addition Cond. Floor Area 707
19
Natural Gas Available Yes
20
Addition Slab Area (ft) 0
21
Glazing Percentage (%) 11.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 203.3 Residential Compliance Report Version - C17111-04072016-744 Report Generated at: 2016-10-12 10:51:55
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
30.33
27.86
2.47
8.1%
Space Cooling
20.93
20.11
0.82
3.9%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
12.03
12.03
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
63.29
60.00
3.29
5.2%
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 203.3 Residential Compliance Report Version - C17111-04072016-744 Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: R-001781.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
Cooling System Verifications:
• Minimum Airflow
• Verified EER
Refrigerant Charge
Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
-- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference, Energy Use Energy Design Rating
Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 108.17 104.88
3.29 3.0%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Residence
2648
1
4
2
0
1
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Input File Name: R-001781.xml
CFI R -PRF -01
Page 3 of 9
ZONE INFORMATION
01
02
03 _ -
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st Floor Existing
Conditioned
Res HVAC1
1941
9
DHW Sys 1
Zone
1st Floor Addition
Conditioned
Res HVAC1
707
9
DHW Sys 1
Status
OPAQUE SURFACES
01
02
03
04
05
06
07
06
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
Left Wall
1st Floor Existing
Default Wall Prior to 197
0
Left
268.6
19
90
Existing
No
Rear Wall
1st Floor Existing
Default Wall Prior to 197
90
Back
481.3
157.2
90
Existing
No
Right Wall
1st Floor Existing
Default Wall Prior to 197
270
Front
316
35
90
Existing
No
Roof
1st Floor Existing
Default Roof Prior to 197
1941
Existing
No
Raised Floor
1st Floor Existing
Default Floor Crawlspace
1941
Existing
No
Front Wall
1st Floor Addition
R-13 Wall1
270
Front
314
65.7
90
New
N/A
Front Wall 2
1st Floor Addition
R-13 Wall1
315
45
16.6
5.3
90
New
N/A
Front Wall 3
1st Floor Addition
R-13 Wall
225 `
315
16.6
5.3
90
New
N/A
Left Wall 2
1st Floor Addition
R-13 Wall
0
Left
79.3
33.3
90
New
N/A
Right Wall 2
1st Floor Addition
R-13 Wall1
180
Right
178.6
32
90
New
N/A
Roof 2
1 st Floor Addition
R-30 Roof Attic
707
New
N/A
Raised Floor 2
1st Floor Addition
R-19 Floor Crawlspace
707
New
N/A
Garage Wall Front
_Garage_
Garage Ext Wall
270
Front
192.6
112
90
Existing
No
Garage Wall Left
Garage_
Garage Ext Wall
0
Left
244.6
40
90
Existing
No
Garage Wall Rear
_Garage_
Garage Ext Wall
90
Back
25.3
0
90
Existing
No
Garage Wall Right
_Garage_
Garage Ext Wall
180
Right
78.6
0
90
Existing
No
GarageRoof
Garage"
R-0 Roof Attic
601
Existing
No
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Input File Name: R-001781.xmi
CFI R -PRF -01
Page 4 of 9
ATTIC
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Radiant
U -factor
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
Attic
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
Eng ti
No
_Garage__
Insect Screen (default)
Existing
No
Windows 3
Right Wall (Front -270)
----
1
35.0
Attic 1st Floor Existing
Attic Rooflst Floor Existing
Ventilated
4
0.1
0.85
No
No
Engti
No
42.4
0.32
0.25
Insect Screen (default)
New
N/A
Window
Front Wall 2 (- specify --315)
----
---
Attic 1st Floor Addition
Attic Rooflst Floor Addition
Ventilated
4
0.1
0.85
No
No
New
No
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Windows
Left Wall (Left -0)
- -
33.3
1
19.0
0.55
0.67
Insect Screen (default)
Existing
No
Windows 2
Rear Wall (Back -90)
----
1
157.2
0.55
0.67
Insect Screen (default)
Existing
No
Windows 3
Right Wall (Front -270)
----
1
35.0
0.55
0.67
Insect Screen (default)
Existing
No
Windows 4
Front Wall (Front -270)
----
----
1
42.4
0.32
0.25
Insect Screen (default)
New
N/A
Window
Front Wall 2 (- specify --315)
----
---
1
5.3
0.71
0.73
Insect Screen (default)
New
N/A
Window 2
Front Wall 3 (- specify --225)
--
1
5.3
0.71
0.73
Insect Screen (default)New
N/A
Windows 5
Right Wall 2 (Right -180)
---
1
32.0
0.32
0.25
Insect Screen (default)
New
N/A
DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ftZ)
U -factor
Status
Verified Existing Condition
Door
Front Wall
23.3
0.50
New
No
Door 2
Left Wall 2
33.3
0.50
New
No
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Input File Name: R-001781.xmi
CFIR-PRF-01
Page 5 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Inside Finish: Gypsum Board
Cavity/ Frame: no insul. / 2x4
• Exterior Finish: Wood
Garage Ext Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.302
Siding/sheathing/decking
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/Frame: no insul. / 2x4
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof 1st Floor Existing
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
• Exterior Finish: Wood
Default Wall Prior to 197
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.302
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/ Frame: R-9.1 /2x4
Default Roof Prior to 197
attic)
Wood Framed Ceiling
2x4 @ 1`6 in. O.C.
R 11
0.083
Over Floor Joists: R-1.9 insul.
• Floor Surface: Carpeted
Floors Over
Floor Deck: Wood Siding/sheathing/decking
Default Floor Crawlspace
Crawlspace
Wood Framed Floor
2x12 @ 16 in. O.C.
none
0.216
Cavity/Frame: no insul. /2x12
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof st Floor Addition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/ Frame: R-13 / 2x4
• Exterior Finish: Wood
R-13 Walll
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/ Frame: R-9.1 / 2x4
R-30 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
Over Floor Joists: R-20.9 insul.
• Floor Surface: Carpeted
Floors Over
Floor Deck: Wood Siding/sheathing/decking
R-19 Floor Crawlspace
e
Crawlspace
Wood Framed Floor
2x6 @ 16 in. O.C.
R 19
0.049
Cavity/Frame: R -19/2x6
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Calculation Description: Title 24 Analysis Input File Name: R-001781.xml
CF1 R -PRF -01
Page 6 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
01
02
03
04
05
06
07
08
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
Tank Volume
Energy Factor or
n/a
Tank Exterior
Standby Loss
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
Insulation R -value
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.575 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a`
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Res HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
2648
Altered
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 V CntrlFurnace - Fuel -fired central furnace 80 AFUE
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Calculation Description: Title 24 Analysis Input File Name: R-001781.xml
CFIR-PRF-01
Page 7 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Name
Verified Airflow
Efficiency
Verified EER
Multi -speed
Verified Refrigerant
Charge
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1SplitAirCond
-Split air conditioning
12 1
14
No
No
Cooling Component
Location
system
Status
Condition
Verification
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Air Distribution System 1 -hers -dist
Required
6.0
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Air Distribution
Ducts located in attic
Sealed and tested
6.0
Attic
Attic
None
Altered
No
System
System 1
1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
Required
6.0
---
-- ---
HVAC - FAN SYSTEMS & HERS VERIFICATION
01 02 03 04
Name Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Calculation Description: Title 24 Analysis Input File Name: R-001781.xml
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744
CF1 R -PRF -01
Page 8 of 9
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-12 10:51:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016
Calculation Description: Title 24 Analysis
Input File Name: R-001781.xml
CF1R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Hector Carbajal
Company:
Signature Date:
Economytitle24
2016-10-12 11:03:38
Address:
CEA/HERS Certification Identification (If applicable):
6055 E. Washington Blvd. Ste. 445
City/State/Zip:
Phone:
Commerce, CA 90040
626-549-1379
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Hector Carbajal
Company:
Date Signed:
Economytitle24
2016-10-12 11:03:38
Address:
License.
6055 E. Washington Blvd. Ste. 445
-
City/State/Zip:
Phone:
Commerce, CA 90040
626-549-1379
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Residence
Building Type 2 Single Family ❑ Addition Alone
❑ Multi Family G2 Existing+ Addition/Alteration
Date
10/12/2016
Project Address
1048 Colony Hills Ln. Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area
2,648
Addition
707
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Wall Wood Framed - no insulation 855
Existing
Roof Wood Framed Attic R 11 1,941
Existing
Floor Wood Framed w/Crawl Space -
no insulation 1,941 _ _
Existing
Demising Wood Framed R 13 571
New
Door Opaque Door - no insulation 57 _
New
Roof Wood Framed Attic R 30 707
New
Floor Wood Framed w/Crawl Space R 19 707
New
FENESTRATION Total Area: 296 Glazing Percentage: 11.2 % New/Altered Average U -Factor:
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades
0.37
Status
Left (N) 19.0 0.550
0.67 none none Bug Screen
Existing
Rear (E) 15T2 0.550
0.67 none none Bug Screen
Existing
Front (1M 35.0 0.550
0.67 none none Bug Screen
Existing
Front (W) 42.4 0.320
0.25 none none Bug Screen
New
Front (NM 5.3 0.710
0.73 none none Bug Screen
New
Right (SW) 5.3 0.710
0.73 none none Bug Screen
New
Right (S) 32.0 0.320
0.25 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 80% AFUE
Split Air Conditioner 14.0 SEER Setback
Altered
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
Res HVAC Ducted
Ducted Attic 6.0
Altered
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
Ener Pro 6.7 by Ener Soft User Number. 6684
RunCode: 2016-10-12710:52:37 ID: R-001781
Pae 12 of 19
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
., 1; -A--4 Ro,,io,n, tho rocnortivo tendo .cortinn fnr mnre infnrmation.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
§ 110.6(a)5:
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
§ 110.8(1):
installation of a cool roof is specified on the CF 1 R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF 1 R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
§ 150.0(c):
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class U vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)i:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
§ 150.0(1):
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
150.0
§ (q)'
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)1 A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
§ 150.0(e)I B:
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e) lC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in § 150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
§ 150.06)2C:
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
§ 150.0(n)3:
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely indirectly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
§ 150.0(m)3-6:
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
§ I50.0(m)7:
dampers.
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
§ 150.0(m)8:
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
§ 150.0(m)9:
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling
§ 150.0(m)15:
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2613 Law -Rice Residential Mandatory Measures Summary
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
§ 110.4(b)1:
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
§ 110.4(b)3:
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
§150.0(k)IA-
150.0-A or TABLE 150.0-B, as applicable.
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
§150.0(k)IB:
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
§150.0(k)IC-
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
§ 150.0(k)1F:
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
§ 150.0(k)2I:
functionality of a dimmer according to § 110.9, and corn lies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
§ 150.0(k)4:
cabinet.
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
§ 150.0(k)5:
shall be high efficacy or controlled by vacancy sensors.
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
§ 150.0(k)6:
controlled by vacancy sensors.
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
§ 150.0(k)7:
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically tum the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, ' 130.0, ' 130.2, ' 130.4, ' 140.7 and ' 141.0.
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
§ 150.0(k)9C:
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
§ 150.0(k)9D:
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
§150.0(k)10:
according to § 130.0(c).
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
§ 150.0(k)11:
nonresidential garages in § 110.9, § 130.0, § 130. 1, ' 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and
§ 150.0(k)12B:
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through 110.10 e .
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
§ 110.10(b)3A:
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
§ 110.10(c):
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
0.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
L1§10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Residence
10/12/2016
System Name
Floor Area
Res HVAC
2,648
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,676
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per Sstem 71,000
34,227
1,519
1,073
41,003
Total Output Btuh 71,000
0
Output Btuh/sgft) 26.8
1,552
2,277
Cooling System
0
0
Output per System 40,500
0
0 0
0
Total Output (Btuh) 40,500
0
0
Total Output (Tons) 3.4
1,552
2,277
Total Output Btuh/s ft
15.3
TOTAL SYSTEM LOAD
1,519
Total Output s ft/Ton 784.6
37,331
45,558
Air System
CFM per System
1,385
HVAC EQUIPMENT SELECTION
Airflow cfm
1,385
HVAC 30,482
8,104
71,000
Airflow cfm/s ft
0.52
Airflow (cfm/Ton)
410.4
Outside Air %)
0.0%
Total Adjusted System Output 30,4821
(Adjusted for Peak Design conditions)
8,1041
— 71,000
0.00
Outside Air cfm/sgft
I TIME OF SYSTEM PEAK
Aug 3 PM
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak
28 OF
66 OF
105 OF 105 OF
10-40. -
- I H -M"
19
Outside Air
.,
0 cfm
Heating Coil Supply Fan
103 OF
1,385 cfm
._.........................
R6�M
66 OF
68 OF
14
.. ...._
i
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak
88/68°F
76/62°F 55/54°F 55/54°F
Outside Air
0 cfmCooling
Coil Supply Fan
56 ! 54 OF
1,385 cfm
46.5%
_.____.........
ROOM
76 / 62 OF
75 / 62 OF
EnergyPro 6.7 by EnergySoft
User Number: 6684 RunCode: 2016-10-12T10:52:37 ID: R-001781 Page 17 of 19
ZONE LOAD SUMMARY
Project Name
Residence
Date
1011212016
System Name
Res HVAC
Floor Area
2,648
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult. CFM Sensible Latent Heating OA CFM Peak Hr
CFM Sensible Latent CFM Sensible
1st Floor Existing
1.0 0 Aug 3PM
1,398 28,551 1,114 881 33,650
1st Floor Addition
1.0 0 Aug 3 PM
278 5,675 406 192 7,353
= TOTALS 0 0 0 0 Aug 3 PM 34,227 1,519 41.003
(BLOCK LOAD)
EnergyPro 6.7 by EnergySoft User Number- 6684 RunCode: 2016-10-12T10:52:37 ID: R-001781 Page 18 of 19
ROOM LOAD SUMMARY
34,227
1,519
1,073
Project Name
Residence
1,676
34,227
Date
10/1212016
System Name
Res HVAC
Floor Area
2,648
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM Sensible Latent
CFM Sensible
1st Floor Existing 1st Floor Existing
1 1,398 28,551 1,114
1,398 28,551 1,114
881 33,650
Fist FloorAdditicn 1st Floor Addition
1 278 5,675 406
278 5,675 406
192 7,353
PAGE TOTAL
TOTAL*
1,676
34,227
1,519
1,073
41,003
1,676
34,227
1,519
1,073�1
41,003
* Total includes ventilation load for zonal systems.
EnergyPro 6.7 by EnergySoft User Number: 6684 RunCode: 2016-10-12T10:52:37 ID: R-001781 Page 19 of 19
_ J
ENTRY
CLOSET
a
QRpF ESSIp�,q
11N-PUNc f Fin
U)
Exp
��glFp� I�AL1Ffl ,��
6
i
P' r
p � C
X`10 HD IT, .
G
�
rim �._, r.
(D 0 m A
0 O t
m _
N iti •TG �^iG'(= .^} �/�(� /''�4 y � e as
p' ;�w . C -
�� Z
i�
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
CUPERTINO (408) 777-3228 • FAX (408) 777-3333 • buildingCa)-cupertino.org act
I -I NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI LJ REVISIO$1 / DEFERRE
ORIGINAL PERMIT #
PROJECT ADDRESSAPN
,17
#
OWNER NAME
PHONE
E-MAIL
STREET ADDRESS
CITY, STATE, ZIP
FAX
CONTACT NAME r-
PHONE
E-MAIL
l
r 6
STREET ADDRESS
CITY, STATE, ZIP
FAX
�cDag
❑ OWNER OWNER -BUILDER ❑ OWNERAGENT ❑ CONTRACTOR ❑ CONTRACTORAGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
9 S I
CONTRACTOR NAME
LICENSE NUMBER S (0
LICENSE TYPE
BUS. LIC #
12)
COMPANY NAME ^
�i
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ARCHITECT/ENGINEER NAME
LICENSE NUMBER
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
DESCRIPTION OF WORK
G1: 1Lt
EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES
USE
TYPE
OCC.
SQ.FT.
VALUATION (S)
EXISTG
NEW FLOOR
DEMO
TOTAL
AREA
AREA
AREA
NET AREA
BATHROOM
KITCHEN
OTHER
REMODEL AREA
REMODEL AREA
REMODEL AREA
PORCH AREA
DECK AREA
TOTAL DECK/PORCH AREA
GARAGE AREA: U DETACH
[]ATTACH
I
DWELLING UNITS:
IS A SECOND UNIT []YES
SECOND STORY ❑ YES
BEING ADDED? []NO
ADDMON? ❑ NO
PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF
IS THE BLDG AN ❑ YESRE
LVED BY:
TOTAL VALUATION:
PLANNING APPL # ❑ NO PLANNTING APPROVAL LETTER
EICHLER HOME? ❑ NO
By my signature below, I certify to each of the following: I am the property owner or authorized agent 0 act onkhe property owner's behalf I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes.
Signature of Applicant/Agent: _ Date:
SUPPLEMENTAI,lNrORMATION REQU
PLAN CHECK TYPE
ROUTING SLIP
❑
❑
New SFD or Multifamily dwellings: Apply for demolition permit for
_
existing building(s). Demolition permit is required prior to issuance of building
OVER-THE-COUNTER
BUILDING PLAN REVIEW
permit for new building.
❑ EXPRESS:
❑ PLANNING PLAN REVIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
❑ STANDARD
❑ PUBLIC WORKS
_
form if any Hazardous Materials are being used as part of this project.
❑ LARGE
❑ FIRE DEPT
_ Copy of Planning Approval Letter or Meeting with Planning prior to
❑
❑
submittal of Building Pen -nit application.
NI AJOR
SANITARY SENVER DISTRICT
❑ ENVIRONMENTAL HEALTH
BldgApp_2011.doc revised 06/21/11
I BUILDING ENERGY ANALYSIS REPORT I
OFFICE CO
PROJECT:
Residence
1048 Colony Hills Ln.
Cupertino, CA 95014 CUPERTINO
Building Department
Project Designer: 1 2015
J B Construction REVIEWED FOR CODE COMPLIANCE
1484 Ramon Drive Reviewed By. -
Sunnyvale, CA 94087
408-738-9581
SUBMITTAL
Report Prepared by:
Hector Carbajal
Economy Title 24
6055 E. Washington Blvd. Ste. 445
Commerce, CA 90040
626-549-1379
Job Number:
R-001781 RECEIVED
Date: SEP 0 3 2015
7/24/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
IThis program developed by EnergySoft, LLC — www.energysoft.com, I
I EneravPro 6.6 by EnergySoft User Number. 6684 ID. R-001781
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Calculation Description: Title 24 Analysis
Input File Name: R-001781.xml
CF1 R -PRF -01
Page 1 of 8
GENERAL INFORMATION
01
Building Complies with Computer Performance
01
Project Name Residence
03
This building incorporates one or more Special Features shown below
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 1048 Colony Hills Ln.
Compliance Margin
Percent Improvement
04
City Cupertino
05
Standards Version Compliance 2015
06
Zip Code 95014
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ4
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 270
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 2648
15
Number of Zones 2
16
Slab Area (ft) 0
17
Number of Stories 1
18
Addition Cond. Floor Area 707
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 0
21
Glazing Percentage (%) 11.2%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
06
Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
26.87
25.16
1.71
6.4%
Space Cooling
17.17
18.10
-0.93
-5.4%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
12.03
12.03
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
56.07
55.29
0.78
1.4%
Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Calculation Description: Title 24 Analysis Input File Name: R-001781.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• New ductwork added is less than 40 ft. in length
CF1 R -PRF -01
Page 2 of 8
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
Cooling System Verifications:
• -- None --
HVAC Distribution System Verifications:
• -- None --
Domestic Hot Water System Verifications:
- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
02
Reference Energy Use
Energy Design Rating
Margin Percent Improvement
Total Energy (kTDV/f2-yr)*
100.95
100.17
0.78 0.8%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Residence
2648
1
4
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st Floor Existing
Conditioned
Res HVAC1
1941
9
DHW Sys 1
1st Floor Addition
Conditioned
Res HVAC1
707
9
DHW Sys 1
Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Calculation Description: Title 24 Analysis
Input File Name: R-001781.xml
CF1 R -PRF -01
Page 3of8
OPAQUE SURFACES
01
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
Left Wall
1 st Floor Existing
Default Wall Prior to 197
0
Left
268.6
19
90
Existing
No
Rear Wall
1 st Floor Existing
Default Wall Prior to 197
90
Back
481.3
157.2
90
Existing
No
Right Wall
1 st Floor Existing
Default Wall Prior to 197
270
Front
316
35
90
Existing
No
Roof
list Floor Existing
Default Roof Prior to 197
Ventilated
4
1941
0.85
No
Existing
No
Raised Floor
1st Floor Existing
Default Floor Crawlspace
1941
Existing
No
Front Wall
1st Floor Addition
R-13 Walll
270
Front
314
65.7
90
New
N/A
Front Wall 2
1 st Floor Addition
R-13 Wall1
315
45
16.6
5.3
90
New
N/A
Front Wall 3
1 st Floor Addition
R-13 Wall l
225
315
16.6
5.3
90
New
N/A
Left Wall 2
1 st Floor Addition
R-13 Walll
0
Left
79.3
33.3
90
New
N/A
Right Wall 2
1st Floor Addition
R-13 Walll
180
Right
178.6
32
90
New
N/A
Roof 2
1 st Floor Addition
R-30 Roof Attic
707
New
N/A
Raised Floor 2
1 st Floor Addition
R-19 Floor Crawlspace
707
New
N/A
Garage Wall Front
_Garage_
Garage Ext Wall
270
Front
192.6
112
90
Existing
No
_ Garage Wall Left
_Garage_
Garage Ext Wall
0
Left
244.6
40
90
Existing
No
Garage Wall Rear
_Garage_
Garage Ext Wall
90
Back
25.3
90
Existing
No
Garage Wall Right
_Garage_
Garage Ext Wall
180
Right
78.6
90
Existing
No
GarageRoof
_Garage_
R-0 Roof Attic
601
Existing
No
ATTIC
01
02 03 04
05
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction Type Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
m_ Attic Garage
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
Enigsti
No
Attic 1st Floor Existing
Attic Rooflst Floor Existing
Ventilated
4
0.1
0.85
No
No
En9ti
No
Attic 1st Floor Addition
Attic Roof 1st Floor Addition
Ventilated
4
0.1
0.85
No
No
New
No
Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Calculation Description: Title 24 Analysis Input File Name: R-001781.xmI
CF1 R -PRF -01
Page 4of8
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiphe
r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Windows
Left Wall (Left -0)
----
----
1
19.0
0.55
0.67
Insect Screen (default)
Existing
No
Windows 2
Rear Wall (Back -90)
----
1
157.2
0.55
0.67
Insect Screen (default)
Existing
No
Windows 3
Right Wall (Front -270)
----
----
1
35.0
0.55
0.67
Insect Screen (default)
Existing
No
Windows 4
Front Wall (Front -270)
----
----
1
42.4
0.32
0.25
Insect Screen (default)
New
N/A
Window
Front Wall 2 (- specify --315)
----
----
1
5.3
0.71
0.73
Insect Screen (default)
New
N/A
Window 2
Front Wall 3 ( specify --225)
1
5.3
0.71
0.73
Insect Screen (default)
New
N/A
Windows 5
Right Wall 2 (Right -180)
1
32.0
0.32
0.25
Insect Screen (default)
New
N/A
DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft)
U -factor
Status
Verified Existing Condition
Door
Front Wall
Left Wall 2
23.3
0.50
New
No
Door 2
I V 3.3.3 0.50 New
No
Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17.47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Calculation Description: Title 24 Analysis
Input File Name: R-001781.xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
• Exterior Finish: Wood
Garage Ext Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.302
Siding/sheathing/decking
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/Frame: no insul. /2x4
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Rooflst Floor Existing
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. 12x4
• Exterior Finish: Wood
Default Wall Prior to 197
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none-
0.302
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Default Roof Prior to 197
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 11
0.083
Over Floor Joists: R-1.9 insul.
• Floor Surface: Carpeted
Floors Over
Floor Deck: Wood Siding/sheathing/decking
Default Floor Crawlspace
Crawlspace
Wood Framed Floor
2x12 @ 16 in. O.C.
none
0.216
Cavity/Frame: no insul. /2x12
• Cavity / Frame: no insul. 12x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Rooflst Floor Addition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-30 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
Over Floor Joists: R-20.9 insul.
• Floor Surface: Carpeted
Floors Over
Floor Deck: Wood Siding/sheathing/decking
R-19 Floor Crawlspace
Crawlspace
Wood Framed Floor
2x6 @ 16 in. O.C.
R 19
0.049
Cavity/ Frame: R -19/2x6
Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Calculation Description: Title 24 Analysis Input File Name: R-001781.xml
CF1 R -PRF -01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.575 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Recirculation with Recirculation with
Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Manual Control Sensor Control
DHW Sys 1 n/a n/a" n/a n/a n/a n/a
SPACE CONDITIONING SYSTEMS
01
4 02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Res HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
2648
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Calculation Description: Title 24 Analysis Input File Name: R-001781.xmi
CFI R -PRF -01
Page 7 of 8
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
11.2
13
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located entirely in
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located entirely in
Existing (not
6.0
Conditioned
Conditioned
None
Existing +New
No
N/A
System 1
conditioned space
specified)
Zone
Zone
0
Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:11, Fri, Jul 24, 2015
Input File Name: R-001781.xml
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Hector Carbajal
Company:
Signature Date:
Economytitle24
2015-07-24 14:17:47
Address:
CEA/HERS Certification Identification (If applicable):
6055 E. Washington Blvd. Ste. 445
City/State/Zip:
Phone:
Commerce, CA 90040
6265491379
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Hector Carbajal
Company:
Date Signed:
Economytitle24
2015-07-24 14:17:47
Address:
License:
6055 E. Washington Blvd. Ste. 445
-
City/State/Zip:
Phone:
Commerce, CA 90040
6265491379
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-07-24 14:12:08
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family [0 Existing+ Addition/Alteration
Date
7/24/2015
Project Address
1048 Colony Hills Ln. Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area
2,648
Addition
707
# of Units
1
INSULATION
Construction Type
Area
Cavity ve) Special Features Status
Wall Wood Framed - no insulation 855 Existing
Roof Wood Framed Attic R 11 1,941 Existing
Floor Wood Framed w/Crawl Space - no insulation 1,941 Existing
Demising Wood Framed R 13 571 New
Door Opaque Door - no insulation 57 New
Roof Wood Framed Attic R 30 707 New
Floor Wood Framed w/Crawl Space R 19 707 New
FENESTRATION I Total Area: 29651azing Percentage: 11.2%1 New/Altered Average U -Factor: 0.37
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Left (N) 19.0 0.550
0.67 none none Bug Screen Existing
Rear (E) 157.2 0.550
0.67 none none Bug Screen Existing
Front (Vtq 35.0 0.550
0.67 none none Bug Screen Existing
Front (VV) 42.4 0.320
0.25 none none Bug Screen New
Front (NVV) 5.3 0.710
0.73 none none Bug Screen New
Right (SM 5.3 0.710
0.73 none none Bug Screen New
Right (S) 32.0 0.320
0.25 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Res HVAC Ducted
Ducted Conditioned 6.0 Altered
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 6.6 by Ener Soft User Number.- 6684
RunCode: 20 1 5-0 7-24 714:11:06 ID: R-001781
Pae 11 of 16
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
r...--- , --L --4 a F....„fi .., ..,,nh, Rvviom tho racnertivo rndo .certinn fnr more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
110.6(a)5:
Coefficient SHGC , and infiltration that meets therequirements of ' 10-111 (a).
§110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
§ 110.8(1):
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
§ 150.0(c):
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11
§150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
§ 150.0(1):
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration.
and when installed as part of a heated slab floor meets the requirements of $110.8( .
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
§ 150.0(q):
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
§ 150.0(e)I B:
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
§ 150.0(e)2:
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§l 10.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
§ 110.3(c)5:
valve, and recirculation loop connection requirements of §I10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§l 10.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
§ 150.0(h)1:
in § 150.0(h)2.
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
§ 150.0(h)3A:
dryer vent.
§150.0(1):
Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c).
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
§ 150.00)1A:
with insulation having an installed thermal resistance of R-12 or greater.
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
§150.0(j)1B:
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
§150.00)2B:
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2613 Law -Rise Residential Mandatory Measures Summary
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
§ 150.00)2C:
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class 1
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class I1 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
§150.0(n)3:
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0.
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
§150.0(m)3-6:
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness: and duct labeling.
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
§ 150.0(m)7:
dampers.
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
§ 150.0(m)8:
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
§150.0(m)9:
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling
§ 150.0(m)l5:
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
§150.0(o)IA:
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
§I 10.4(b)1:
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
§ 110.4(b)3:
rammed to run only during off-peak electric demand periods.
§110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
§150.0(k)lA:
150.0-A or TABLE 150.0-B, as applicable.
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
§150.0(k)IB:
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
§ I50.0(k)I C:
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ I50.0(k)I E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
§150.0(k)IF:
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if it functions as a dimmer
§150.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
§150.0(k)21:
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § I50.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
§ 150.0(k)4:
cabinet.
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
§ I50.0(k)5:
shall be high efficacy or controlled by vacancy sensors.
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
§ I50.0(k)6:
controlled by vacancy sensors.
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
§ I50.0(k)7:
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2011 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ I50.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in $110.9, $130.0, § 130.2, § 130.4, $140.7 and § 141.0.
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
§ I50.0(k)9C:
shall comply with the applicable requirements in § 110.9, § 1 30 § 130.2, § 130.4, § 140.7 and $141.0.
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
§ I50.0(k)9D:
with the applicable requirements in §1109, §130.01 §130.2, §130.4, §140.7 and §141.0.
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
§150.0(k)10:
according to ' 130.0(c).
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
§150.0(k)] 1:
nonresidential garages in 110.9, §130.0, 130.1, §130.4, 140.6, and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in § 110.9. § 130.0, § 130.1, § 140.6 and § 141.0; and
§ 150.0(k)12B:
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014.
shall comply with therequirements of §I 10.10(b) through §I 10.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § ] 10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I 10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
§ 110.10(b)3A:
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
§ 110.10(b)4:
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
§ 110.10(c):
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(e)
§ 110.10(d):
shall be provided to the occupant.
§1 10.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
ENERGY USE AND COST SUMMARY
ECON-1
Project Name
Residence
_
_
Date
7/24/2015
Rate: Electric Alameda H
_
Fuel Type:
Electricity
STANDARD
_
PROPOSED
MARGIN
Energy !
Use
(kWh)
Peak
Demand I
(kW) 1
Cost
($)
Energy
Use
(kWh)
Peak 1
Demand !
(kW
Cost
$
Energy
Use
(kWh)
Peak
Demand Cost
(kW) $
Jan
575
1.4 1
64
�i 570 1
1.4
64
1 5
0.0
0
Feb
476
1.3 1
54
472
1.2
54
3
0.0
0
Mar
469
1.2
53
!! 467
1.2
53
2
0.0
0
Apr
417
1.7 I
48 ? 416
1.8
48
J 1
-0.1
0
May
452
3.3
56 �;; 454
3.5
56
-3
-0.2
0
Jun
437
3.3
53
44i
3.51
54
-3
-0.2
0
Jul
566
3.4
i
77
j'; 574
3.5
78
' -7
-0.2
-1
Aug
509
3.4
66
5181
3.51
68
-9
-0.2
-2
Sep
633
3.51
89
, 645
3.71
_
91
-12
-0.2
-2
Oct
455
1.1
57 455
1.1
57
0
0.0
0
Nov
518
1.3
58
5151
1.3
58
4
0.0
0
Dec
581
1.4
65
'1 576
1.4
64
5
0.0
0
Year
6,088
3.5
741
6,102
3.71
745
-14
-0.2
-4
4,901
lbs/yr
.912
lbs/yrCO2
Rate: Gas PG&E P
Fuel T e: Natural Gas
STANDARD
PROPOSEDMARGIN
Energy
Use
(therms)
Peak
Demand
(kBtu/hr)
Cost
($)
Energy
Use
(therms)
Peak
Demand i
(kBtu/hr)
Cost
($)
Energy
Use
(therms)
Peak
Demand Cost
(kBtu/hr) ($)
Jan
113
77.0
152
108
75.2
145
5
1.8
8
Feb
8211
69.2 1
107
(' 78
67.4
101
4
1.8
5
Mar
61
73.9
77
59
72.3
73
3
1.6
3
Apr
49
61.2
61
48 ;
59.9
59
2
1.3
2
May
25
37.1
33
24
35.3
32
0
1.8
0
Jun
1 19
6.2
25
19
6.2
25
0
0.0
0
Jul
20
6.0 I
26
1 20 1
6.0
26
0
0.0
0
Aug20
5.8
25
20
5.8
25
0
0.0
0
Se
19
5.8
25
19
5.8
25
0
0.0
0
Oct
23
50.0
30
22
46.4
29
0
3.6
0
Nov
77
76.6
99
72
75.1
93
4
1.5
6
Dec
112
70.6
150
106
69.1
142
5
1.5
8
Year
619
77.0
809
596
75.2
776
23
1.8
33
CO2
7,243
lbs/yr
6.973.
lt�s/ r
270
lbs/yr
Annual
Totals
En rgy
Demand
Cost
Cost/s ft
Virtual Rate
Electricity
6,102 kWh
4 kW
$ 745
$
0.28 /s ft
$ 0.12 /kWh
Natural Gas
596 therms
75 kBtu/hr
$ 776
$
0.29 /s ft
$ 1.30 /therm
Total
$ 1,521 $ 0.57 /s ft
Avoided CO2 Emissions:
259 lbs/yr
EnergyPro 6.6 by EnergySoft
User Number: 6684
RunCode: 2015-07-24T14:11:0 ID: R-001781
Page 16 of 16
CERTIFICATE OF INSTALLATION
CF2R-MCH-20-H
Duct Leakage Diagnostic Test
(Page 1 of 3 )
Project Name: R-0017
Enforcement Agency:
Cupertino
City of
Permit Number: 15090011
Dwelling Address: 1048 Colony Hills Ln.
City:
Cupertino
Zip Code: 95014
A. System Information
01
Space Conditioning System Identification or Name
System 1
02
Space Conditioning System Location or Area Served
Whole House
03
Building Type from CF -111
Single family
04
Verified Low Leakage Ducts in Conditioned Space
(VLLDCS) Credit from CF1R?
No, credit is not taken
05
Verified Low Leakage Air Handling Unit (VLLAHU) Credit
from CF1R?
No, credit is not taken
06
Duct System Compliance Category
Replacement
MCH -20d - Complete Replacement or Altered Duct System
B. Duct Leakage Diagnostic Test
01
Condenser Nominal Cooling Capacity (ton)
5
02
Heating Capacity (kBtu/h)
97
03
Conditioned Floor Area served by this HVAC system (ft2)
2648
04
Duct Leakage Test Condition
Test final
05
Duct Leakage Test Method
Total leakage
06
Leakage Factor
0.06
07
Air Handling Unit Airflow (AHUAirflow) Determination
Method
Heating system method
08
Measured AHUAirflow
This field or section is not applicable
09
Calculated Target Allowable Duct: Leakage (cfm)
126
10
Actual duct leakage rate from leakage test measurement
(cfm)
118
11
Compliance Statement
System passes leakage test
Registration Number: 215-A0205183B-M2000001A-0000 Registration Date/Time: 2017-06-04 23:18:08 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-06-01 17:30:03
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION CF2R-MCH-20-H
Duct Leakage Diagnostic Test (Page 3 of 3 )
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Jose Novelo
Company:
Signature Date: 2017-06-01 17:29:53
California Air Duct Testers
Address:
CEA/ HERS Certification Identification (if applicable):
5279 Eggers Dr
City/State/Zip:
Phone:
1408-824-0740
Fremont CA 94536
Responsible Person's Declaration statement
1 certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design,
construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of
Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the
responsible builder/installer.
3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation
conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by
the enforcement agency.
4. 1 understand that a HERS rater will check the installation to verify compliance, and that if such checking identifies defects; I am required to take
corrective action at my expense. I understand that Energy Commission and HERS Provider representatives will also perform quality assurance checking
of installations, including those approved as part of a sample group but not checked by a HERS rater, and if those installations fail to meet the
requirements of such quality assurance checking, the required corrective action and additional checking/testing of other installations in that HERS
sample group will be performed at my expense.
5. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of
construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or
installation have been met.
6. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of
Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Responsible Builder/Installer Signature:
Claudia Ortega
( �
Company Name: (Installing Subcontractor or General Contractor or
Position With Company (Title): OF
Builder/Owner)
manager
A & 0 CONSTRUCTION
Address:
CSLB License:
236 S CRAGMONT AVENUE
951051
City/State/Zip:
Phone:
Date Signed:
SAN JOSE CA 95127
408-687-2615 X123
2017-06-04 2318:08
Third Party Quality Control Program (TPQCP) Status:
Name of TPQCP (if applicable):
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies
Registration Provider responsibility for the accuracy of the information.
Registration Number: 215-A0205183B-M2000001A-0000 Registration Date/Time: 2017-06-04 23:18:08 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-06-01 17:30:03
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION CFZR-MCH-20-H
Duct Leakage Diagnostic Test (Page 2 of 3 )
C. Additional Requirements for Compliance
01
System was tested in its normal operation condition. No temporary taping allowed.
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage
02
testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation
Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required,
may configure the OA damper to the closed position during duct leakage testing.
03
If a complete replacement, all supply and return register boots were sealed to the drywall.
04
Building cavities were not used as plenums or platform returns in lieu of ducts.
05
If cloth backed tape was used it was covered with Mastic and draw bands.
06
All connection points between the air handler and the supply and return plenums are completely sealed.
If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements
07
of Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample
groups for HERS verification compliance.
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have
been met.
Registration Number: 215-A0205183B-M2000001A-0000 Registration Date/Time: 2017-06-04 23:18:08 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-06-01 17:30:03
2013 Residential Compliance Schema Version: 2013.1.007