Loading...
15090011CITY OF CUPERTINO BUILDING PERMIT BUILDINGADDRESS: CONTRACTOR: PERMIT NO: 15090011 1048 COLONY HILLS IN CUPERTINO CA 95014 (359 28 040) A & O CONSTRUCTION SAN JOSE, CA 95035 OWNER'S NAME: ANUMALA MOHNISH AND SREELAXMI DATE ISSUED: 05/09/2016 OWNER'S PHONE: PHONE NO: (408) 687-2615 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class GENERAL BUILDING CONTRACTOR tic. # 5105 Contractor A& O CONSTRUCTION Date 08/31/2016 _BLDG _ELECT _PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing MECH _ RESIDENTIAL _ COMMERCIAL _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: CONSTRUCT ONE STORY ADDITION (707 SQ FT); KITCHEN I hereby affirm under penalty of perjury one of the following two declarations: REMODEL (216 SQ FT); REMODEL OTHER (298 SQ FT). x. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the 'DEF #1 - TRUSS CALCS - ISSUED 7/26/16 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $110000.00 APPLICANT CERTIFICATION certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 359 28 040 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST PECTION. Signature// . < 3'���%t% Date07/26/1S Issued by: MELISSA N Date: 05/09/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 07/26/16 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER i. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain: compliance with the Cupertino Municipal Code, Chapter 9.12 and the s. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agent: APPLICANT CERTIFICATION - Date: 07/26/16 1 certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city Of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in, Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 07/26/16 Professional I CITY OF CUPERTINO BUILDING PERMIT BUHMINGADDRESS- CONTRACTOR: PERMIT NO: 15090011 1048 COLONY HILLS LN CUPERTINO CA 95014 (359 28 040) A & O CONSTRUCTION SAN JOSE, CA 95035 OWNER'S NAME: ANUMALA MOHNISH AND SREELAXMI OWNER'S PHONE: 978-486-4643 LICENSED CONTRACTOR'S DECLARATION License Class j} Lic. #951051 Contractor A& O CONSTRUCTION Date 08/31/2016 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is In full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: t. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. z. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant underAtands and will comply with all non -point source regulations pefhfleZ'tino Municipal Code, Section 9.18. 00M=1 Date . DATE ISSUED: 05/09/2016 PHONE NO: (408) 687-2615 BUILDING PERMIT INFO: BLDG —ELECT _ PLUMB MECH _ RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: CONSTRUCT ONE STORY ADDPI'ION (707 SQ FT); KITCHEN REMODEL (216 SQ FT); REMODEL OTHER (298 SQ FT). Sq. Ft Floor Area: I Valuation: $110000.00 "N Number: Occupancy Type: 359 28 040 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Alex Vallelung0 4kr4lo' narP. n 5m4nm F I hereby affirm that I am exempt from the Contractor's License Law for one of the RE- ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is t. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) z. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: t. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. z. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 5/9/2016 Signature of Applicant: Date: 5/9/2016 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Munici ial Code, Chapter 9.12 and the Health & Safety Code, Secti 533, and 25534. Owner or authorized agent: U �A Date: 5/9/2016 I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CUPERTIN0 CONS i RUCCaT VISION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 �, / (408) 777-3228 • FAX (408) 777-3333 • buildino(a.cuDertino.org / NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION i TI EV%ISION I EFERRED ORIGINAL PERAZIT 9 PROJECT ADDRESS I r OWNER NAME PHONE S E-DLAIL STREET ADDRESS I CITY, STATE, ZIP FAX CON'T.ACT NAME � I PHONE STREET ADDRESS CITY, STATE, ZIP FAX C ❑ OANER ❑ OW1.ER-BL-IIDER ❑ OWNERAGE.N'T ❑ CO1vTRACT0R ❑ CON77RACTORAGENT ❑ ARCHITECT ❑ ENGPMM ❑ DEVELOPER ❑ T -:A -,T CONTRACTOR -NAME LICENSE NUMBER LICENSE TYPE BUS. LIC R CO"\Y TAME E44AIL FAX 44YV STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECTIENGLN'EER NAME LICENSE NUMBER BUS. LIC COMPANY NAME E-? WL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK , tk EXISTiVG USE PROPOSED USE CONSTR TYPE R STORIES USE TYPE OCC, SQ.FT. VALUATION (S) EXISTG NEW FLOOR DEXIO TOTAL AREA AREA ARE4 NET AREA BATHROOM KrrCHEl. OTHER REMODELAREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKPORCH AREA GARAGE AREA: DETACH ❑ ATTACH DWELLPJG UNITS: IS A SECOND L`NIT ❑ YES SECOND STORY ❑ YES BELNG ADDED? ❑ NO ADDITION? ❑ NO _ PRE•APPLICATION ❑ 1'ES 71 ES, PROVIDE COPY OF IS THE BLDG AN 11119 zf TOTAL VALUATION: PL4\T:G I N"L;, By my signature below, I certify to each of the following: I am the property owner or authorize a. o t&Z'Ne property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of)Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize repres tatives of Cupertino to enter the above -Id ntified property for inspection purposes. Si -nature of Applicant/Agent: Date: SUPPLEI` AIIvrFORl`4ATION RE D � New SFD or Multifamily dwellings: Apply for demolition pennit for existing buildins(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EGRESS KM. I, ' NNNINc I I, :E,� �- r Bldgs: Provide a completed Hazardous Materials Disclosure `❑� STA\D , .' _Commercial Torn if any Hazardous >`4aterials are being used as part of this project. ❑ Copy of Planning Approval Letter or Meeting with Planning prior to�tR LARCL1 'fl r T,- P; I _ submittal of Building Permit application. z�r -LJ KR INSk�3x. >.w ,.�:�. EN1'IRO\'�TE1T4L 1~E.SL--Ii B1dgApp_2011.doc revised 06/21111 [Smoot j CONSTRUCTION PERMIT APPLICATION Val COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE CUPERTINO, CA 95014-3255 g j (408) 777-3228 • FAX (408) 777-3333 • buildingCcDcupertino.org 1 CUPERTINO: ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI 2_REVISIO // bEFERRE ' ORIGINAL PERMIT # PROJECT ADDRESS p _ APN OWNER NAME PHONE - E-MAIL\ c on) L STREET ADDRESS CITY, STATE, ZIP FAX CONTACT NAMEL� r PHONE E-MAIL 211 k L r, AIAu010d.a 91 STREET ADDRESS CITY, STATE, ZIP FAX S l YVL C o ❑ OWNER OWNER-BunDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑' ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER 115 (O5 / LICENTSE TYPE BUS. LIC # COMPANY NAME E-MAIL _ FAX i "Vneo STREET ADDRESS i CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK ,I" T L 4 EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES I USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NETAREA - BATHROOM KITCHEN OTHER REMODELAREA REMODEL AREA REMODELAREA PORCH AREA DECK AREA TOTAL DECKTORCH AREA GARAGE AREA: DETACH ATTACH 9DWELLII.TG.UNITS: IS A SECOND UNIT ❑YES SECONDSTORY ❑YES '- BEING ADDED? ❑ NO ADDITION? ❑NO PRE -APPLICATION ❑.YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES ; RE. IV TOTAL VALUATION: PLANNING APPL # ❑ 1\10. PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each of the following: I am the property owner or authorized agent ta act on e property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified roperty for inspection purposes. Signature ofApplicant/Agent: Date: SUPPLEMENTORMATiON REQU P PLAL\ CHECKTIPE ROITT ING SLIP , o� ER THE eour TER n f�1 BUILDING PI Atvrlt> vlEw g New SFD or Multifamily dwellings: Apply for demolition permit for _ existing building(s). Demolition permit is required prior to issuance of buildmQ b 5Si t permit for new building. EXTRESS_' y PLAl1NINGPLAN REv3EP4 Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ sTANDARD ❑arIIBLIc�voRxs _ form if any Hazardous Materials are being used as part of this project. El ❑FIRE LARGE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to I+3Aro ❑==sANrrARX sEa3�R DISTRICT � _ submittal of Building Permit application. B1dgApp_2011.doC revised 06121111 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS; . ' , CONTRACTOR: PERMIT NO: 15090011 1048 COLONY BILLS LN CUPERTINO CA 95014 (359 28 040) A & O CONSTRUCTION SAN JOSE, CA 95035 OWNER'S NAME: ANUMALA MOHNISH AND SREELAXNII DATE ISSUED: 05/09/2016 OWNER'S PHONE: 978-486-4643 PRONE NO: (408) 687-2615 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B Lie. #951051 Contractor A& O CONSTRUCTION Date 08/31/2016 —BLDG —ELECT _ PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing. — MECH RESIDENTIAL— COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: CONSTRUCT ONE STORY ADDITION (707 SQ FT); KITCHEN I hereby affirm under penalty of perjury one of the following two declarations: REMODEL (216 SQ FT); REMODEL OTHER (298 SQ FT). 1. 1 have and willmaintaina certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (�'2J I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $110000.00 permit is issued. APPLICANT CERTIFICATION certify that I have read this application and state that the above information is correct. t agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 359 28 040 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT' ISSUANCE OR Additionally, the applicant under tands and will comply with all non -point source regulations pe a C71ino Municipal Code, Section 9,18. 180 DAYS FROM LAST CALLED INSPECTION. _Signature--, �.%� bA ` Date 5L9L2016 Issued by: Alex Vallclunea 4/1 OVVINER ER DECL ION Date: 05/09/2016 14 I hereby affirm that I am exempt from the Contractor's License Law for one of the - following two reasons: All roofs shall be inspected prior to E ny roofing material being installed. If a roof is 1. 1, as owner of the property, or my employees with wages as their sole installed without first obtaining an in pection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (See.7044, Business & Professions Code) 2. 1, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sce.7044, Business & Professions Code), Date: 5/9/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. 1 have and will maintain a Certificate of Consent to self -insure for Worker's - Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. 1 have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cup rtino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 2 532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I us air contaminants as defined by the equipment or devices which emit hazardous Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the upertino Munici al Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Cod , Sec ti and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall 1533, be deemed revoked Owner=o► authorized agents f APPLICANT CERTIFICATION Date:/5 9/2016 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws CONS TION I hereby affirm that there is a cons E ruction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands AR HI T S DECLARATION and will comply with all non -point source regulations per the Cupertino Municipal u I understand my plans shall be used as public records. Code, Section 9.18. Licensed Signature Date 5/9/2016 Professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUP1_RTlNt3 (408) 777-3228 • FAX (408) 777-3333 • building o)cupertino.org/ � o ❑ NEW CONSTRUCTION tj ADDITION ❑ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS APN # 13 f OWNERNAME AN 0M PHONE 7 � / ,`F 3 tl ry E PI VI i S —0 nu MGL`a � a; oAe C�} v STREET ADDRESS 1e z elm (i SLS 9 CITY, STATE, ZIPFAX �U� R?i CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISIO ADDRESS: 1048 COLONY HILLS LN FEE DATE: .09101/2015 REVIEWED BY: SEAN APN: BP#: F 216-1 s.f. $645.0.0 *VALUATION: $,110;0007-7, *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY USE: SFD or Duplex 2nd Unit? Yes � No ' OTC. O Yes ®No PE PERMIT TAMATION TYPE: 1 R3SFDADD WORK ' CONSTRUCT ONE STORY ADDITION 707 SQ FT • KITCHEN REMOD L 216 SQ FT); REMODEL SCOPE OTHER (298 SQ FT). hrs $0.00 TYPE OF FLR AREA OCCUPANCY TYPE: CONSTR. s.f. PC FEES PC FE ID BP FEES BP FEE ID r R-3 (Custom) 11-B,111-B,IV,V-B 707654,00i IR3PL CK $1,666.00 IR37NSP TOTALS: 1 707 1$2,654.000 $1,666.001-- Mech. 1,666 00 Mech. Plan ('heck Pluillb. Plan Checti plea:, I lan Cheep F:ti9L>rta. Z'eraa7it Fee: Plkarnh. Permit Fee: liiec. Permit` Fee: (.Xher ,ilesla. Insp.E]_L__ Other Plvnib Ip. Ofhei, kc. lnsll>. 44ech. InspPee: I Phunb. Insp. Fee: fI ec. I sly. Fee NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, re, Sanitary Sewer District, School District. ate.). These fees are ha.ced an the nreliminary information available and are only an estimat Contact the DeDt for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,654.00 F 216-1 s.f. $645.0.0 Remode 1, Kitchen (<=300 sf) IREMRESKIT Suppl. PC Fee: (j) Reg. 0 OT 0.0hrs $0.00 PME Plan Check: $0.00 F-2-9-8-1 s.£ _ $431.QQ Remode 1, Other IREMRESOTH Permit Fee: $1,666.00 Suppl. Insp. Feer Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 C'onsfruetion 1 av: Administrative Fee: E) Work Without Permit? 0 Yes No $0.00 Advanced Planning Fee: IPLLONGR $98.98 Selec a Non -Residential Building or Structure 0' � Travel Doc'umentation Fees. Strong Motion Fee: IBSEISMICR $14.30 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $5:00„ SUBTDTAES $4,438.28 $1,076.00 5,514.28 Revised: 07/02/2015 BUILDING ENERGY ANALYSIS REPORT PROJECT: Residence 1048 Colony Hills Ln. Cupertino, CA 95014 Project Designer: J B Construction 1484 Ramon Drive Sunnyvale, CA 94087 408-738-9581 Report Prepared by: NIIISIQN Hector Carbajal Economy Title 24 6055 E. Washington Blvd. Ste. 445 Commerce, CA 90040 626-549-1379 RECEIVED 3 By GUPEl R INO Building Department OCT 1120% REVIEWED FOR CODE COMPLIANCE Job Number: ReviOWed By: J �"1 R-001781 Date: 10/12/2016 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. IThis program developed by EnergySoft, LLC — www.energysoft.com. L. EnergyPro 6.7 by EnergySort User Number.• 6884 ID: R-001781 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 12 Form MF -1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 17 Zone Load Summary 18 Room Load Summary 19 EneravPro 6.7 by EneravSoft I�h w ,nay ID: R-001781 User Number: 6684 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CFI R -PRF -01 Page 1 of 9 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Residence 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 1048 Colony Hills Ln. Compliance Margin Percent Improvement 04 City Cupertino 05 Standards Version Compliance 2015 06 Zip Code 95014 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ4 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2648 15 Number of Zones 2 16 Slab Area (ft2) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 707 19 Natural Gas Available Yes 20 Addition Slab Area (ft) 0 21 Glazing Percentage (%) 11.2% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 203.3 Residential Compliance Report Version - C17111-04072016-744 Report Generated at: 2016-10-12 10:51:55 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 30.33 27.86 2.47 8.1% Space Cooling 20.93 20.11 0.82 3.9% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 12.03 12.03 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 63.29 60.00 3.29 5.2% Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 203.3 Residential Compliance Report Version - C17111-04072016-744 Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) Cooling System Verifications: • Minimum Airflow • Verified EER Refrigerant Charge Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference, Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 108.17 104.88 3.29 3.0% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Residence 2648 1 4 2 0 1 Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Input File Name: R-001781.xml CFI R -PRF -01 Page 3 of 9 ZONE INFORMATION 01 02 03 _ - 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 1st Floor Existing Conditioned Res HVAC1 1941 9 DHW Sys 1 Zone 1st Floor Addition Conditioned Res HVAC1 707 9 DHW Sys 1 Status OPAQUE SURFACES 01 02 03 04 05 06 07 06 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition Left Wall 1st Floor Existing Default Wall Prior to 197 0 Left 268.6 19 90 Existing No Rear Wall 1st Floor Existing Default Wall Prior to 197 90 Back 481.3 157.2 90 Existing No Right Wall 1st Floor Existing Default Wall Prior to 197 270 Front 316 35 90 Existing No Roof 1st Floor Existing Default Roof Prior to 197 1941 Existing No Raised Floor 1st Floor Existing Default Floor Crawlspace 1941 Existing No Front Wall 1st Floor Addition R-13 Wall1 270 Front 314 65.7 90 New N/A Front Wall 2 1st Floor Addition R-13 Wall1 315 45 16.6 5.3 90 New N/A Front Wall 3 1st Floor Addition R-13 Wall 225 ` 315 16.6 5.3 90 New N/A Left Wall 2 1st Floor Addition R-13 Wall 0 Left 79.3 33.3 90 New N/A Right Wall 2 1st Floor Addition R-13 Wall1 180 Right 178.6 32 90 New N/A Roof 2 1 st Floor Addition R-30 Roof Attic 707 New N/A Raised Floor 2 1st Floor Addition R-19 Floor Crawlspace 707 New N/A Garage Wall Front _Garage_ Garage Ext Wall 270 Front 192.6 112 90 Existing No Garage Wall Left Garage_ Garage Ext Wall 0 Left 244.6 40 90 Existing No Garage Wall Rear _Garage_ Garage Ext Wall 90 Back 25.3 0 90 Existing No Garage Wall Right _Garage_ Garage Ext Wall 180 Right 78.6 0 90 Existing No GarageRoof Garage" R-0 Roof Attic 601 Existing No Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Input File Name: R-001781.xmi CFI R -PRF -01 Page 4 of 9 ATTIC 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Radiant U -factor Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Attic Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Eng ti No _Garage__ Insect Screen (default) Existing No Windows 3 Right Wall (Front -270) ---- 1 35.0 Attic 1st Floor Existing Attic Rooflst Floor Existing Ventilated 4 0.1 0.85 No No Engti No 42.4 0.32 0.25 Insect Screen (default) New N/A Window Front Wall 2 (- specify --315) ---- --- Attic 1st Floor Addition Attic Rooflst Floor Addition Ventilated 4 0.1 0.85 No No New No WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Windows Left Wall (Left -0) - - 33.3 1 19.0 0.55 0.67 Insect Screen (default) Existing No Windows 2 Rear Wall (Back -90) ---- 1 157.2 0.55 0.67 Insect Screen (default) Existing No Windows 3 Right Wall (Front -270) ---- 1 35.0 0.55 0.67 Insect Screen (default) Existing No Windows 4 Front Wall (Front -270) ---- ---- 1 42.4 0.32 0.25 Insect Screen (default) New N/A Window Front Wall 2 (- specify --315) ---- --- 1 5.3 0.71 0.73 Insect Screen (default) New N/A Window 2 Front Wall 3 (- specify --225) -- 1 5.3 0.71 0.73 Insect Screen (default)New N/A Windows 5 Right Wall 2 (Right -180) --- 1 32.0 0.32 0.25 Insect Screen (default) New N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ftZ) U -factor Status Verified Existing Condition Door Front Wall 23.3 0.50 New No Door 2 Left Wall 2 33.3 0.50 New No Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Input File Name: R-001781.xmi CFIR-PRF-01 Page 5 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Inside Finish: Gypsum Board Cavity/ Frame: no insul. / 2x4 • Exterior Finish: Wood Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. / 2x4 • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof 1st Floor Existing Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 • Exterior Finish: Wood Default Wall Prior to 197 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 /2x4 Default Roof Prior to 197 attic) Wood Framed Ceiling 2x4 @ 1`6 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Floor Surface: Carpeted Floors Over Floor Deck: Wood Siding/sheathing/decking Default Floor Crawlspace Crawlspace Wood Framed Floor 2x12 @ 16 in. O.C. none 0.216 Cavity/Frame: no insul. /2x12 • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof st Floor Addition Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/ Frame: R-13 / 2x4 • Exterior Finish: Wood R-13 Walll Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 / 2x4 R-30 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.032 Over Floor Joists: R-20.9 insul. • Floor Surface: Carpeted Floors Over Floor Deck: Wood Siding/sheathing/decking R-19 Floor Crawlspace e Crawlspace Wood Framed Floor 2x6 @ 16 in. O.C. R 19 0.049 Cavity/Frame: R -19/2x6 Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CF1 R -PRF -01 Page 6 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 01 02 03 04 05 06 07 08 Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 Tank Volume Energy Factor or n/a Tank Exterior Standby Loss Name Heater Element Type Tank Type (gal) Efficiency Input Rating Insulation R -value (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a` n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Res HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2648 Altered No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 V CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CFIR-PRF-01 Page 7 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1SplitAirCond -Split air conditioning 12 1 14 No No Cooling Component Location system Status Condition Verification 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Air Distribution System 1 -hers -dist Required 6.0 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Air Distribution Ducts located in attic Sealed and tested 6.0 Attic Attic None Altered No System System 1 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist Required 6.0 --- -- --- HVAC - FAN SYSTEMS & HERS VERIFICATION 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 CF1 R -PRF -01 Page 8 of 9 HERS Provider: CaICERTS inc. Report Generated at: 2016-10-12 10:51:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 10:51, Wed, Oct 12, 2016 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CF1R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Hector Carbajal Company: Signature Date: Economytitle24 2016-10-12 11:03:38 Address: CEA/HERS Certification Identification (If applicable): 6055 E. Washington Blvd. Ste. 445 City/State/Zip: Phone: Commerce, CA 90040 626-549-1379 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Hector Carbajal Company: Date Signed: Economytitle24 2016-10-12 11:03:38 Address: License. 6055 E. Washington Blvd. Ste. 445 - City/State/Zip: Phone: Commerce, CA 90040 626-549-1379 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0205183B-000000000-0000 Registration Date/Time: 2016-10-12 11:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-12 10:51:55 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Residence Building Type 2 Single Family ❑ Addition Alone ❑ Multi Family G2 Existing+ Addition/Alteration Date 10/12/2016 Project Address 1048 Colony Hills Ln. Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,648 Addition 707 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Wall Wood Framed - no insulation 855 Existing Roof Wood Framed Attic R 11 1,941 Existing Floor Wood Framed w/Crawl Space - no insulation 1,941 _ _ Existing Demising Wood Framed R 13 571 New Door Opaque Door - no insulation 57 _ New Roof Wood Framed Attic R 30 707 New Floor Wood Framed w/Crawl Space R 19 707 New FENESTRATION Total Area: 296 Glazing Percentage: 11.2 % New/Altered Average U -Factor: Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades 0.37 Status Left (N) 19.0 0.550 0.67 none none Bug Screen Existing Rear (E) 15T2 0.550 0.67 none none Bug Screen Existing Front (1M 35.0 0.550 0.67 none none Bug Screen Existing Front (W) 42.4 0.320 0.25 none none Bug Screen New Front (NM 5.3 0.710 0.73 none none Bug Screen New Right (SW) 5.3 0.710 0.73 none none Bug Screen New Right (S) 32.0 0.320 0.25 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Altered HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Res HVAC Ducted Ducted Attic 6.0 Altered WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.7 by Ener Soft User Number. 6684 RunCode: 2016-10-12710:52:37 ID: R-001781 Pae 12 of 19 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the ., 1; -A--4 Ro,,io,n, tho rocnortivo tendo .cortinn fnr mnre infnrmation. Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain § 110.6(a)5: Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the § 110.8(1): installation of a cool roof is specified on the CF 1 R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF 1 R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - § 150.0(c): factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class U vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)i: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; § 150.0(1): have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- 150.0 § (q)' factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is § 150.0(e)I B: equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § 150.0(e) lC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). § 150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating § 150.06)2C: systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) § 150.0(n)3: or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely indirectly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other § 150.0(m)3-6: requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic § I50.0(m)7: dampers. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers § 150.0(m)8: except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, § 150.0(m)9: sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling § 150.0(m)15: capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. § 150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2613 Law -Rice Residential Mandatory Measures Summary Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction § 110.4(b)1: and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- § 110.4(b)3: grammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE §150.0(k)IA- 150.0-A or TABLE 150.0-B, as applicable. When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply §150.0(k)IB: with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has §150.0(k)IC- been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to be controlled by vacancy sensors. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable § 150.0(k)1F: requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the § 150.0(k)2I: functionality of a dimmer according to § 110.9, and corn lies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated § 150.0(k)4: cabinet. A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom § 150.0(k)5: shall be high efficacy or controlled by vacancy sensors. Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and § 150.0(k)6: controlled by vacancy sensors. Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high § 150.0(k)7: efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, ' 130.0, ' 130.2, ' 130.4, ' 140.7 and ' 141.0. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D § 150.0(k)9C: shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply § 150.0(k)9D: with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined §150.0(k)10: according to § 130.0(c). Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for § 150.0(k)11: nonresidential garages in § 110.9, § 130.0, § 130. 1, ' 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and § 150.0(k)12B: ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10(b) through 110.10 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be § 110.10(b)3A: located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of § 110.10(c): interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. 0.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a L1§10.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Residence 10/12/2016 System Name Floor Area Res HVAC 2,648 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,676 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per Sstem 71,000 34,227 1,519 1,073 41,003 Total Output Btuh 71,000 0 Output Btuh/sgft) 26.8 1,552 2,277 Cooling System 0 0 Output per System 40,500 0 0 0 0 Total Output (Btuh) 40,500 0 0 Total Output (Tons) 3.4 1,552 2,277 Total Output Btuh/s ft 15.3 TOTAL SYSTEM LOAD 1,519 Total Output s ft/Ton 784.6 37,331 45,558 Air System CFM per System 1,385 HVAC EQUIPMENT SELECTION Airflow cfm 1,385 HVAC 30,482 8,104 71,000 Airflow cfm/s ft 0.52 Airflow (cfm/Ton) 410.4 Outside Air %) 0.0% Total Adjusted System Output 30,4821 (Adjusted for Peak Design conditions) 8,1041 — 71,000 0.00 Outside Air cfm/sgft I TIME OF SYSTEM PEAK Aug 3 PM Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 28 OF 66 OF 105 OF 105 OF 10-40. - - I H -M" 19 Outside Air ., 0 cfm Heating Coil Supply Fan 103 OF 1,385 cfm ._......................... R6�M 66 OF 68 OF 14 .. ...._ i COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 88/68°F 76/62°F 55/54°F 55/54°F Outside Air 0 cfmCooling Coil Supply Fan 56 ! 54 OF 1,385 cfm 46.5% _.____......... ROOM 76 / 62 OF 75 / 62 OF EnergyPro 6.7 by EnergySoft User Number: 6684 RunCode: 2016-10-12T10:52:37 ID: R-001781 Page 17 of 19 ZONE LOAD SUMMARY Project Name Residence Date 1011212016 System Name Res HVAC Floor Area 2,648 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible 1st Floor Existing 1.0 0 Aug 3PM 1,398 28,551 1,114 881 33,650 1st Floor Addition 1.0 0 Aug 3 PM 278 5,675 406 192 7,353 = TOTALS 0 0 0 0 Aug 3 PM 34,227 1,519 41.003 (BLOCK LOAD) EnergyPro 6.7 by EnergySoft User Number- 6684 RunCode: 2016-10-12T10:52:37 ID: R-001781 Page 18 of 19 ROOM LOAD SUMMARY 34,227 1,519 1,073 Project Name Residence 1,676 34,227 Date 10/1212016 System Name Res HVAC Floor Area 2,648 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 1st Floor Existing 1st Floor Existing 1 1,398 28,551 1,114 1,398 28,551 1,114 881 33,650 Fist FloorAdditicn 1st Floor Addition 1 278 5,675 406 278 5,675 406 192 7,353 PAGE TOTAL TOTAL* 1,676 34,227 1,519 1,073 41,003 1,676 34,227 1,519 1,073�1 41,003 * Total includes ventilation load for zonal systems. EnergyPro 6.7 by EnergySoft User Number: 6684 RunCode: 2016-10-12T10:52:37 ID: R-001781 Page 19 of 19 _ J ENTRY CLOSET a QRpF ESSIp�,q 11N-PUNc f Fin U) Exp ��glFp� I�AL1Ffl ,�� 6 i P' r p � C X`10 HD IT, . G � rim �._, r. (D 0 m A 0 O t m _ N iti •TG �^iG'(= .^} �/�(� /''�4 y � e as p' ;�w . C - �� Z i� CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUPERTINO (408) 777-3228 • FAX (408) 777-3333 • buildingCa)-cupertino.org act I -I NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI LJ REVISIO$1 / DEFERRE ORIGINAL PERMIT # PROJECT ADDRESSAPN ,17 # OWNER NAME PHONE E-MAIL STREET ADDRESS CITY, STATE, ZIP FAX CONTACT NAME r- PHONE E-MAIL l r 6 STREET ADDRESS CITY, STATE, ZIP FAX �cDag ❑ OWNER OWNER -BUILDER ❑ OWNERAGENT ❑ CONTRACTOR ❑ CONTRACTORAGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT 9 S I CONTRACTOR NAME LICENSE NUMBER S (0 LICENSE TYPE BUS. LIC # 12) COMPANY NAME ^ �i E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK G1: 1Lt EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES USE TYPE OCC. SQ.FT. VALUATION (S) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: U DETACH []ATTACH I DWELLING UNITS: IS A SECOND UNIT []YES SECOND STORY ❑ YES BEING ADDED? []NO ADDMON? ❑ NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YESRE LVED BY: TOTAL VALUATION: PLANNING APPL # ❑ NO PLANNTING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each of the following: I am the property owner or authorized agent 0 act onkhe property owner's behalf I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: _ Date: SUPPLEMENTAI,lNrORMATION REQU PLAN CHECK TYPE ROUTING SLIP ❑ ❑ New SFD or Multifamily dwellings: Apply for demolition permit for _ existing building(s). Demolition permit is required prior to issuance of building OVER-THE-COUNTER BUILDING PLAN REVIEW permit for new building. ❑ EXPRESS: ❑ PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS _ form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ ❑ submittal of Building Pen -nit application. NI AJOR SANITARY SENVER DISTRICT ❑ ENVIRONMENTAL HEALTH BldgApp_2011.doc revised 06/21/11 I BUILDING ENERGY ANALYSIS REPORT I OFFICE CO PROJECT: Residence 1048 Colony Hills Ln. Cupertino, CA 95014 CUPERTINO Building Department Project Designer: 1 2015 J B Construction REVIEWED FOR CODE COMPLIANCE 1484 Ramon Drive Reviewed By. - Sunnyvale, CA 94087 408-738-9581 SUBMITTAL Report Prepared by: Hector Carbajal Economy Title 24 6055 E. Washington Blvd. Ste. 445 Commerce, CA 90040 626-549-1379 Job Number: R-001781 RECEIVED Date: SEP 0 3 2015 7/24/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. IThis program developed by EnergySoft, LLC — www.energysoft.com, I I EneravPro 6.6 by EnergySoft User Number. 6684 ID. R-001781 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CF1 R -PRF -01 Page 1 of 8 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Residence 03 This building incorporates one or more Special Features shown below 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 1048 Colony Hills Ln. Compliance Margin Percent Improvement 04 City Cupertino 05 Standards Version Compliance 2015 06 Zip Code 95014 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ4 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2648 15 Number of Zones 2 16 Slab Area (ft) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 707 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 11.2% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 06 Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 26.87 25.16 1.71 6.4% Space Cooling 17.17 18.10 -0.93 -5.4% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 12.03 12.03 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 56.07 55.29 0.78 1.4% Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • New ductwork added is less than 40 ft. in length CF1 R -PRF -01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: - None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. 02 Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 100.95 100.17 0.78 0.8% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Residence 2648 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 1st Floor Existing Conditioned Res HVAC1 1941 9 DHW Sys 1 1st Floor Addition Conditioned Res HVAC1 707 9 DHW Sys 1 Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CF1 R -PRF -01 Page 3of8 OPAQUE SURFACES 01 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition Left Wall 1 st Floor Existing Default Wall Prior to 197 0 Left 268.6 19 90 Existing No Rear Wall 1 st Floor Existing Default Wall Prior to 197 90 Back 481.3 157.2 90 Existing No Right Wall 1 st Floor Existing Default Wall Prior to 197 270 Front 316 35 90 Existing No Roof list Floor Existing Default Roof Prior to 197 Ventilated 4 1941 0.85 No Existing No Raised Floor 1st Floor Existing Default Floor Crawlspace 1941 Existing No Front Wall 1st Floor Addition R-13 Walll 270 Front 314 65.7 90 New N/A Front Wall 2 1 st Floor Addition R-13 Wall1 315 45 16.6 5.3 90 New N/A Front Wall 3 1 st Floor Addition R-13 Wall l 225 315 16.6 5.3 90 New N/A Left Wall 2 1 st Floor Addition R-13 Walll 0 Left 79.3 33.3 90 New N/A Right Wall 2 1st Floor Addition R-13 Walll 180 Right 178.6 32 90 New N/A Roof 2 1 st Floor Addition R-30 Roof Attic 707 New N/A Raised Floor 2 1 st Floor Addition R-19 Floor Crawlspace 707 New N/A Garage Wall Front _Garage_ Garage Ext Wall 270 Front 192.6 112 90 Existing No _ Garage Wall Left _Garage_ Garage Ext Wall 0 Left 244.6 40 90 Existing No Garage Wall Rear _Garage_ Garage Ext Wall 90 Back 25.3 90 Existing No Garage Wall Right _Garage_ Garage Ext Wall 180 Right 78.6 90 Existing No GarageRoof _Garage_ R-0 Roof Attic 601 Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition m_ Attic Garage Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No Enigsti No Attic 1st Floor Existing Attic Rooflst Floor Existing Ventilated 4 0.1 0.85 No No En9ti No Attic 1st Floor Addition Attic Roof 1st Floor Addition Ventilated 4 0.1 0.85 No No New No Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Calculation Description: Title 24 Analysis Input File Name: R-001781.xmI CF1 R -PRF -01 Page 4of8 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiphe r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition Windows Left Wall (Left -0) ---- ---- 1 19.0 0.55 0.67 Insect Screen (default) Existing No Windows 2 Rear Wall (Back -90) ---- 1 157.2 0.55 0.67 Insect Screen (default) Existing No Windows 3 Right Wall (Front -270) ---- ---- 1 35.0 0.55 0.67 Insect Screen (default) Existing No Windows 4 Front Wall (Front -270) ---- ---- 1 42.4 0.32 0.25 Insect Screen (default) New N/A Window Front Wall 2 (- specify --315) ---- ---- 1 5.3 0.71 0.73 Insect Screen (default) New N/A Window 2 Front Wall 3 ( specify --225) 1 5.3 0.71 0.73 Insect Screen (default) New N/A Windows 5 Right Wall 2 (Right -180) 1 32.0 0.32 0.25 Insect Screen (default) New N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition Door Front Wall Left Wall 2 23.3 0.50 New No Door 2 I V 3.3.3 0.50 New No Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17.47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CF1 R -PRF -01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 • Exterior Finish: Wood Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking Ceilings (below Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Rooflst Floor Existing Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: no insul. 12x4 • Exterior Finish: Wood Default Wall Prior to 197 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none- 0.302 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default Roof Prior to 197 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Floor Surface: Carpeted Floors Over Floor Deck: Wood Siding/sheathing/decking Default Floor Crawlspace Crawlspace Wood Framed Floor 2x12 @ 16 in. O.C. none 0.216 Cavity/Frame: no insul. /2x12 • Cavity / Frame: no insul. 12x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Rooflst Floor Addition Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-30 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.032 Over Floor Joists: R-20.9 insul. • Floor Surface: Carpeted Floors Over Floor Deck: Wood Siding/sheathing/decking R-19 Floor Crawlspace Crawlspace Wood Framed Floor 2x6 @ 16 in. O.C. R 19 0.049 Cavity/ Frame: R -19/2x6 Registration Number: 215-A0205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Calculation Description: Title 24 Analysis Input File Name: R-001781.xml CF1 R -PRF -01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Recirculation with Recirculation with Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Manual Control Sensor Control DHW Sys 1 n/a n/a" n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 4 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Res HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2648 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Calculation Description: Title 24 Analysis Input File Name: R-001781.xmi CFI R -PRF -01 Page 7 of 8 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.2 13 No No N/A Location system Status Condition Verification Air Distribution Ducts located entirely in HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located entirely in Existing (not 6.0 Conditioned Conditioned None Existing +New No N/A System 1 conditioned space specified) Zone Zone 0 Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-24 14:12:08 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 14:11, Fri, Jul 24, 2015 Input File Name: R-001781.xml CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Hector Carbajal Company: Signature Date: Economytitle24 2015-07-24 14:17:47 Address: CEA/HERS Certification Identification (If applicable): 6055 E. Washington Blvd. Ste. 445 City/State/Zip: Phone: Commerce, CA 90040 6265491379 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Hector Carbajal Company: Date Signed: Economytitle24 2015-07-24 14:17:47 Address: License: 6055 E. Washington Blvd. Ste. 445 - City/State/Zip: Phone: Commerce, CA 90040 6265491379 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-Ao205183A-000000000-0000 Registration Date/Time: 2015-07-24 14:17:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-07-24 14:12:08 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family [0 Existing+ Addition/Alteration Date 7/24/2015 Project Address 1048 Colony Hills Ln. Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,648 Addition 707 # of Units 1 INSULATION Construction Type Area Cavity ve) Special Features Status Wall Wood Framed - no insulation 855 Existing Roof Wood Framed Attic R 11 1,941 Existing Floor Wood Framed w/Crawl Space - no insulation 1,941 Existing Demising Wood Framed R 13 571 New Door Opaque Door - no insulation 57 New Roof Wood Framed Attic R 30 707 New Floor Wood Framed w/Crawl Space R 19 707 New FENESTRATION I Total Area: 29651azing Percentage: 11.2%1 New/Altered Average U -Factor: 0.37 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Left (N) 19.0 0.550 0.67 none none Bug Screen Existing Rear (E) 157.2 0.550 0.67 none none Bug Screen Existing Front (Vtq 35.0 0.550 0.67 none none Bug Screen Existing Front (VV) 42.4 0.320 0.25 none none Bug Screen New Front (NVV) 5.3 0.710 0.73 none none Bug Screen New Right (SM 5.3 0.710 0.73 none none Bug Screen New Right (S) 32.0 0.320 0.25 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Res HVAC Ducted Ducted Conditioned 6.0 Altered WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.6 by Ener Soft User Number.- 6684 RunCode: 20 1 5-0 7-24 714:11:06 ID: R-001781 Pae 11 of 16 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the r...--- , --L --4 a F....„fi­ .., ..,,nh, Rvviom tho racnertivo rndo .certinn fnr more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain 110.6(a)5: Coefficient SHGC , and infiltration that meets therequirements of ' 10-111 (a). §110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the § 110.8(1): installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - § 150.0(c): factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § I50.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; § 150.0(1): have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration. and when installed as part of a heated slab floor meets the requirements of $110.8( . Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - § 150.0(q): factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is § 150.0(e)I B: equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §I50.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside § 150.0(e)2: of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§l 10.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation § 110.3(c)5: valve, and recirculation loop connection requirements of §I10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §l 10.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified § 150.0(h)1: in § 150.0(h)2. Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any § 150.0(h)3A: dryer vent. §150.0(1): Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c). Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped § 150.00)1A: with insulation having an installed thermal resistance of R-12 or greater. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external §150.0(j)1B: insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve §150.00)2B: that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2613 Law -Rise Residential Mandatory Measures Summary Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating § 150.00)2C: systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class 1 §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class I1 vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) §150.0(n)3: or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0. §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § I50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other §150.0(m)3-6: requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness: and duct labeling. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic § 150.0(m)7: dampers. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers § 150.0(m)8: except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, §150.0(m)9: sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling § 150.0(m)l5: capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with §150.0(o)IA: Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction §I 10.4(b)1: and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - § 110.4(b)3: rammed to run only during off-peak electric demand periods. §110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: §110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9. Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE §150.0(k)lA: 150.0-A or TABLE 150.0-B, as applicable. When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply §150.0(k)IB: with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has § I50.0(k)I C: been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § I50.0(k)I E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable §150.0(k)IF: requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. §150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). §150.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if it functions as a dimmer §150.0(k)2G: according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the §150.0(k)21: functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § I50.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated § 150.0(k)4: cabinet. A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom § I50.0(k)5: shall be high efficacy or controlled by vacancy sensors. Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and § I50.0(k)6: controlled by vacancy sensors. Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high § I50.0(k)7: efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2011 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § I50.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in $110.9, $130.0, § 130.2, § 130.4, $140.7 and § 141.0. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D § I50.0(k)9C: shall comply with the applicable requirements in § 110.9, § 1 30 § 130.2, § 130.4, § 140.7 and $141.0. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply § I50.0(k)9D: with the applicable requirements in §1109, §130.01 §130.2, §130.4, §140.7 and §141.0. Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined §150.0(k)10: according to ' 130.0(c). Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for §150.0(k)] 1: nonresidential garages in 110.9, §130.0, 130.1, §130.4, 140.6, and §141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in § 110.9. § 130.0, § 130.1, § 140.6 and § 141.0; and § 150.0(k)12B: ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014. shall comply with therequirements of §I 10.10(b) through §I 10.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § ] 10.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §I 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be § 110.10(b)3A: located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly § 110.10(b)4: indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of § 110.10(c): interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(e) § 110.10(d): shall be provided to the occupant. §1 10.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". ENERGY USE AND COST SUMMARY ECON-1 Project Name Residence _ _ Date 7/24/2015 Rate: Electric Alameda H _ Fuel Type: Electricity STANDARD _ PROPOSED MARGIN Energy ! Use (kWh) Peak Demand I (kW) 1 Cost ($) Energy Use (kWh) Peak 1 Demand ! (kW Cost $ Energy Use (kWh) Peak Demand Cost (kW) $ Jan 575 1.4 1 64 �i 570 1 1.4 64 1 5 0.0 0 Feb 476 1.3 1 54 472 1.2 54 3 0.0 0 Mar 469 1.2 53 !! 467 1.2 53 2 0.0 0 Apr 417 1.7 I 48 ? 416 1.8 48 J 1 -0.1 0 May 452 3.3 56 �;; 454 3.5 56 -3 -0.2 0 Jun 437 3.3 53 44i 3.51 54 -3 -0.2 0 Jul 566 3.4 i 77 j'; 574 3.5 78 ' -7 -0.2 -1 Aug 509 3.4 66 5181 3.51 68 -9 -0.2 -2 Sep 633 3.51 89 , 645 3.71 _ 91 -12 -0.2 -2 Oct 455 1.1 57 455 1.1 57 0 0.0 0 Nov 518 1.3 58 5151 1.3 58 4 0.0 0 Dec 581 1.4 65 '1 576 1.4 64 5 0.0 0 Year 6,088 3.5 741 6,102 3.71 745 -14 -0.2 -4 4,901 lbs/yr .912 lbs/yrCO2 Rate: Gas PG&E P Fuel T e: Natural Gas STANDARD PROPOSEDMARGIN Energy Use (therms) Peak Demand (kBtu/hr) Cost ($) Energy Use (therms) Peak Demand i (kBtu/hr) Cost ($) Energy Use (therms) Peak Demand Cost (kBtu/hr) ($) Jan 113 77.0 152 108 75.2 145 5 1.8 8 Feb 8211 69.2 1 107 (' 78 67.4 101 4 1.8 5 Mar 61 73.9 77 59 72.3 73 3 1.6 3 Apr 49 61.2 61 48 ; 59.9 59 2 1.3 2 May 25 37.1 33 24 35.3 32 0 1.8 0 Jun 1 19 6.2 25 19 6.2 25 0 0.0 0 Jul 20 6.0 I 26 1 20 1 6.0 26 0 0.0 0 Aug20 5.8 25 20 5.8 25 0 0.0 0 Se 19 5.8 25 19 5.8 25 0 0.0 0 Oct 23 50.0 30 22 46.4 29 0 3.6 0 Nov 77 76.6 99 72 75.1 93 4 1.5 6 Dec 112 70.6 150 106 69.1 142 5 1.5 8 Year 619 77.0 809 596 75.2 776 23 1.8 33 CO2 7,243 lbs/yr 6.973. lt�s/ r 270 lbs/yr Annual Totals En rgy Demand Cost Cost/s ft Virtual Rate Electricity 6,102 kWh 4 kW $ 745 $ 0.28 /s ft $ 0.12 /kWh Natural Gas 596 therms 75 kBtu/hr $ 776 $ 0.29 /s ft $ 1.30 /therm Total $ 1,521 $ 0.57 /s ft Avoided CO2 Emissions: 259 lbs/yr EnergyPro 6.6 by EnergySoft User Number: 6684 RunCode: 2015-07-24T14:11:0 ID: R-001781 Page 16 of 16 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3 ) Project Name: R-0017 Enforcement Agency: Cupertino City of Permit Number: 15090011 Dwelling Address: 1048 Colony Hills Ln. City: Cupertino Zip Code: 95014 A. System Information 01 Space Conditioning System Identification or Name System 1 02 Space Conditioning System Location or Area Served Whole House 03 Building Type from CF -111 Single family 04 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 05 Verified Low Leakage Air Handling Unit (VLLAHU) Credit from CF1R? No, credit is not taken 06 Duct System Compliance Category Replacement MCH -20d - Complete Replacement or Altered Duct System B. Duct Leakage Diagnostic Test 01 Condenser Nominal Cooling Capacity (ton) 5 02 Heating Capacity (kBtu/h) 97 03 Conditioned Floor Area served by this HVAC system (ft2) 2648 04 Duct Leakage Test Condition Test final 05 Duct Leakage Test Method Total leakage 06 Leakage Factor 0.06 07 Air Handling Unit Airflow (AHUAirflow) Determination Method Heating system method 08 Measured AHUAirflow This field or section is not applicable 09 Calculated Target Allowable Duct: Leakage (cfm) 126 10 Actual duct leakage rate from leakage test measurement (cfm) 118 11 Compliance Statement System passes leakage test Registration Number: 215-A0205183B-M2000001A-0000 Registration Date/Time: 2017-06-04 23:18:08 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-06-01 17:30:03 2013 Residential Compliance Schema Version: 2013.1.007 CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jose Novelo Company: Signature Date: 2017-06-01 17:29:53 California Air Duct Testers Address: CEA/ HERS Certification Identification (if applicable): 5279 Eggers Dr City/State/Zip: Phone: 1408-824-0740 Fremont CA 94536 Responsible Person's Declaration statement 1 certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 understand that a HERS rater will check the installation to verify compliance, and that if such checking identifies defects; I am required to take corrective action at my expense. I understand that Energy Commission and HERS Provider representatives will also perform quality assurance checking of installations, including those approved as part of a sample group but not checked by a HERS rater, and if those installations fail to meet the requirements of such quality assurance checking, the required corrective action and additional checking/testing of other installations in that HERS sample group will be performed at my expense. 5. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 6. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Claudia Ortega ( � Company Name: (Installing Subcontractor or General Contractor or Position With Company (Title): OF Builder/Owner) manager A & 0 CONSTRUCTION Address: CSLB License: 236 S CRAGMONT AVENUE 951051 City/State/Zip: Phone: Date Signed: SAN JOSE CA 95127 408-687-2615 X123 2017-06-04 2318:08 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0205183B-M2000001A-0000 Registration Date/Time: 2017-06-04 23:18:08 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-06-01 17:30:03 2013 Residential Compliance Schema Version: 2013.1.007 CERTIFICATE OF INSTALLATION CFZR-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3 ) C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage 02 testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 03 If a complete replacement, all supply and return register boots were sealed to the drywall. 04 Building cavities were not used as plenums or platform returns in lieu of ducts. 05 If cloth backed tape was used it was covered with Mastic and draw bands. 06 All connection points between the air handler and the supply and return plenums are completely sealed. If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements 07 of Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample groups for HERS verification compliance. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 215-A0205183B-M2000001A-0000 Registration Date/Time: 2017-06-04 23:18:08 HERS Provider: CaICERTS CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-06-01 17:30:03 2013 Residential Compliance Schema Version: 2013.1.007