Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2016-1890
CITY OF CUPERTINO BUILDING PERMIT BUILDINGADDRESS: CONTRACTOR: PERMIT NO:B-2016-1890 21398 KRZICH PL CUPERTINO, CA 95014-4943 (362 06 041) SANTA CRUZ WESTSIDE ELECTRIC INC SANTA CRUZ, CA 95060 OWNER'S NAME: SINGH RAM D AND SPRIHA TRUSTEE OWNER'S PHONE: 831-332-8400 LICENSED CONTRACTOR'S DECLARATION License Class C-10 Lic. #846294 Contractor SANTA CRUZ WESTSIDE ELECTRIC INC Date 04/30/2017 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: t. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by `;f Section 3700 of the Labor Code, for the performance of the work for which this `permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ode, Section 9.18. XW__ gnat,17R p Date 5/5/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shalla, be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. DATE ISSUED: 05/05/2016 PHONE NO: (831) 469-8888 BUILDING PERMIT INFO: BLDG X ELECT _ PLUMB MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: INSTALL 24 ROOFTOP MOUNTED PV SOLAR PANELS (5.28KW); REPLACE 125 AMP MAIN PANEL Sq. Ft Floor Area: l Valuation: $21000.00 APN Number: Occupancy Type: 362 06 041 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLE INSPECTION. Issued by: Alex Vallelunaa Date: OS/OS/2016 I RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 5/5/2016 TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal ode, Chapter 9.12 and the Health & Safety Code, GSeectioons25505, 25 3, a 25534. Owner or authorizes - g nt: _l�u"6s2 Date: 5/5/2016 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Signature. Date 5/5/2016 Licensed CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE e CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408)177-3333 • building a acupertino.org AE PROJECT ADDRESS 21398 Krzich Place APN# 362-060-41 OWNER NAME Ram Singh PHONE I_ 33,Z Fj E-MAIL STREET ADDRESS 21398 KZrICh Place CITY, STATE, ZIP Cupertino, CA 95014 FAX CONTACT NAME Kristi Cassetta PHONE831-226-9363 E-MAIL kcassetta@sandbarsc.Com STREET ADDRESS 2119 Delaware Avenue CITY, STATE, ZIP Santa Cruz Ca 95060 FAX 831-515-5098 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # Sandbar 846294 C-10��Z� �a to Guru Westside Electric dba Sandbar E kcassetta sandbarsc.com FAX 831-515-5098 9TREET2119 Delaware Avenue SantA6, Cruz Ca 95060 PHONE31-469-8888 ARCHITECT/ENGINEER NAME Sun evit LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL Sam - sholing@sungevity.com FAX STREET ADDRESS 66 Franklin Street Ste. 310 CITY, STATE, ZIP Oakland CA 94607 PHONE USE OF X SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: El Commercial �{ URBAN INTERFACE AREA ❑ Yes Jy NO FLOOD ZONE ❑ Yes ❑ NO IX SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS. NUMBER OF PANELSIUNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: $21, 000 DESCRIPTION OF WORK t Installation of a 6kw grid tied photovoltaic solar array roof mount Z 4 A-ejL__C 6. 2-� lL vv 2,� ,-V f� f —� RECEIVED BY: By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have prov'ded`is co ect. I h v read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to build ng co s cti., I t o ize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: l Date: ti SUPPLEMENTAL INFORMATION REQUIRED= vFFicE usEoivLY . W ❑ OVER-THE-COUNTER x ❑ EXPRESS U W ❑ STANDARD U e ❑ ' LARGE - MAJOR PVApp_2011.doc revised 03116111 CITY OF CUPERTINO 10MI FEE ESTIMATOR - BUILDING DIVISION t ADDRESS: ___7DATE: REVIEWED BY: APN: BP#: VALUATION: 1$21,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: PENTAMATION SOLAR -RE PERMIT TYPE: WORK SCOPE >t,,. 1'i;xrt '. ,_ t't.d:io. 'icar: .:'t rtf Elec. Plan Check 0.0 hrs $0.00 r=r,=e:r _ ? i r. itrinb. r''c' ..<it , e: Elec. Permit Fee: IEPERMIT Other Elec. Insp. L0.0 hrs $48.00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School I)istrirt etc )_ These fees are haled on the nreliminary information available and are onlv an estimate. Contact the Dent for addn'l into. FEE ITEMS (Fee Resolution 1.1-033.Fff. 7/1/.13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1� # $236.00 Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 125 amps $48.00 Electrical IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 Permit Flee: $48.00 /rPNM X. L.. Cs`Fi t �fdfd io;- n: Administrative Fee: 1ADMIN $45.00 0 0 Work Without Permit? 0 Yes (E) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure i Travel Documentation Fee: ITRAVDOC $48.00 Strong Motion Fee: 1BSEISMICR $2.73 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOT LR., $144.73 $284.00 TOTAL FEE: $428.73 Revised: 10/01/2015 ■ ■ PHOTOVOLTAIC SYSTEM SYSTEM SIZE: AC / DC kW STC EQUIPMENT: A PV MODULES: INVERTER(S): 5.28kW \ 6kW (24) Trina Solar TSM-250 PD05.05 (1) ABB PVI-6000-OUTD-US-A SCOPE OF WORK: INSTALLATION OF A SAFE AND CODE -COMPLIANT GRID -TIED SOLAR PV SYSTEM ON AN EXISTING RESIDENTIAL ROOF TOP. D z n i 3 i D n (E) GATE z z L. ._.-.-.-.-.-.-._.-.-.-.-.-. ._.T _ 71 R-1 M E;v I 0fv1N1UNITY DEVELOPME�l ' `r}`� RTI�'�O BUILDING DIVISION - ;.�. APPROVED This set of plans and specifications NIU ST be kept at�0OF MOUNTED job site during construction. It is u:(I e,f onto deviateONDUIT(TYP.) changes or alterations on s Ifl official. ✓ therefrom„ Without approval froln the Building Stamping of This plan and speci�icatior;s SHALL NOT The Stamp g prov.1 of the violation be held to permit or to be an (di ante or State Law• y provisio.r o an - E (JI ERtSt1IT� � sunGEVITYO GENERATE POSITIVE" i ROOF 1 ARRAY 1 SITE PLAN N SCALE : N.T.S. KRZICH PI. n DRIVEWAY F'------ - --- -•-•- -•---------------•-•--- G o I ROOF 2 ARRAY 2 CUPERTINO a SHEETINDEX PV0.0 COVER AND SITE PLAN PV1.0 GENERAL NOTES PV2.0 - 2.1 ARRAY LAYOUT PV3.0 LINE DIAGRAM PV4.0 LABELS KEY: ---- PROPERTY LINE — — — CONDUIT RUN INV INVERTER DRIVEWAY Ea SUBPANEL FENCE o DC DISCONNECT FIRE CLEARANCE A= AC DISCONNECT STRUCTURAL UPGRADES DDE].IUNCTION BOX SOLAR MODULE I] MONITORING UNIT MAIN MAIN SERVICE PANEL 0 COMBINER BOX 0 UTILITY METER ROOF 0 PV METER OBSTRUCTION APPLICABLE CODES: 2013 CEC (BASED ON 2011 NEC) 2013 CBC 2013 CRC 2013 CPC 2013 CMC 2013 CFC LOCAL AMENDMENTS TO CA CODES CONTRACTOR INFORMATION: B SANDBAR SAN JOSE 2119 DELAWARE AVE SANTA CRUZ, CA 95060 JURISDICTIONAL INFORMATION: CUPERTINO, CITY OF 10300 TORRE AVENUE CUPERTII�1fh1j0 m NOTES 'ib4ATAI<L ,.TiG8nt U REVIEW D FOR CODE COMPLIANCE POST INSTALL SUN EYES REQUIRED? YES I CERTIFY THAT NO CHANGES HAVE BEEN MADE TO THE ARRAY LAYOUT: CUSTOMER INFORMATION: RAM SINGH 21398 KRZICH PLACE CUPERTINO, CA 95014 /#2590890 - APN:36206041 DESIGNED BY: REV #: DATE: PV- 0.0 AN -AND S. 0 5/3/16 IUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 6Y: MHEINZE Date:— Locawn: 5mgn - zoau— ovl anee: 5rze: nz l r I I' M UIWVVIIVUJ, rCI.IrII.M I I M. NINU Ut51UN5 AKC I — rrt 11 1 -1 -, 11.... - 1-, - -11 - ...._., ..n __ ..,..+, - I.. — .... .......... ......-.. 1... 1.1 .. ,- , , ,,, .1 1-1 1 „ - ". , - -- .., 1—— — ,,,,,...,., , , "1 I ri J 4 GENERAL NOTES: GENERAL NOTES: N1. DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. N2. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. N3. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVERCURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL.EQUIPMENTAND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. N4. ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. N5. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. N6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 61, ABOVE FLUSH VENTS. N7. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. N8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. N9. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE 3 SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10 N10. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. N11. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. N12. IT IS ILLEGAL FOR ANYONE UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFFESIONAL ENGINEER OR REGISTERED ARCHITECTTO ALTER ANY ITEMS ON THIS PLAN. N13. THE ENGINEER HAS NOT BEEN RETAINED FOR JOB SUPERVISION. N.14 ALL OSHA REGULATIONS AND STANDARDS FOR SAFE AND HEALTHFUL WORKING CONDITIONS TO BE FOLLOWED. N.15 ALL CONTRACTORS WORKING ON ROOFS TO BE INSURED AS SUCH. STRUCTURAL NOTES: S1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED. IS2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS. S3. DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS. ELECTRICAL NOTES: E1. ALL EQUIPMENT IS LISTED FOR USE. E2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. E3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. E4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUTTO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTILTHE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. E5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED ATTHAT COMPONENT. E7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. E8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM. E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. E10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E11. FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. E12. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. E15. BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E16. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED E19. ALL MODULES AND RACKING SHALL BE GROUNDED VIA IRON RIDGE RAIL INTEGRATED GROUNDING (PLEASE SEE DATA SHEET) OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS. E20. ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. PE `= BUildiny De;2er ment i� �v7J REVIEWED FOR CODE OC-10 p) pAINCE Reviewed By: sunGEVITYm GENERATE POSITIVE - CI INl.1FVITV Wf` A. FRANKI IN ST SUITF 11n 0AKI ANTI (:A Odom Bv: MHEIN7F Date:- Location: Sinah - 2590890 SW Sheet Size: 11x17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT j 7■ G 3'-8" 32'-9" 3'-7" NOTE: MODULES SHALL NOT BE GREATER THAN 8 mr.HFS ARCI\/F Rnop (,n\/FRINIC, SOLAR MOD IRONRIDGE � L—Fi QMSE—LAG SHIN COMPOSITE SHIN 5" X 5/16" — 2.5" MIN. EMBEDMENT SCF 2X6 NOMINAL, 24 MOUNTING DETAIL 2 SCALE: NTS sunGEVITY° GENERATE POSITIVE' N■L■7� CONTINUE TO I RO& 1 I I ARRXY 1 ARRAY 1 L:YOUT 1'-5" 581 ROOF 1 SECTION J MODULE SPECIFICATIONS (24) Trina Solar TSM-250 PD05.05 MODULE WEIGHT: 41 MODULE LENGTH: 64.95 MODULE WIDTH: 39.05 ROOF 1SPECS RAFTER SIZE: 2X6 NOMINAL RAFTER SPAN: 8' - 0" RAFTER SPACING: 24" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 1SPECS NUMBER OF MODULES: 20 TOTAL MOD. WEIGHT (Ibs): 820 RACKING WEIGHT (Ibs): 78.7 ARRAY WEIGHT (Ibs): 898.7 ARRAY AREA (sqft): 352.3 ARRAY DEAD LOAD (lbs/sgft): 2.6 NUMBER OF MOUNTS: 28 LOAD PER MOUNT(Ibs): 32.1 ARRAY AZIMUTH(') 179 ARRAY TILT(') 21 NUMBER OF FLOORS 2 SYMBOL KEY: ------- RAIL — — — — RAFTERS ROOF FIRE CLEARANCE ®............. ® STRING CONFIG. STRUCTURAL UPGRADES C3 SOLAR MODULE ® MOUNT ® SKYLIGHT ® CHIMNEY C PLUMBING OR ATTIC VENT �9 etE9 g1I ATTIC VENT Sullding D rurt�I . U� CODE CoMPUANCE d By: m Ir ■ L: ■r CUSTOMER INFORMATION: RAM SINGH 21398 KRZICH PLACE CUPERTINO, CA 95014 /#2590890 DESIGNED BY: REV #: DATE: PV- 2.0 ANAND S. 0 5/3/16 JNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: MHEINZE Date:— Location: Singh - 2590890 SVt Sheet Size: 11x17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSEt sm IN sunGEVITYm GENERATE POSITIVE' CONTINUE FROM ...........................: 13'-1" 3' ARRAY 1 I f I I I I I I I I I I I I I I I I I I ( I I I I I I I I I I I I I I I I I I co I I I I I i I I I I I I I I I O -- L I-- -- i -- ......................... ...... �............ .. lllllllill I10) 11 LID I ( I I 1 1 1 1 1 1 1 1 1 1 1 1� I I I 1 1 ROOT 2 1 I ARR�Y 2 1 1 I l l l i i l l l l l l l l l l l i l I I I I I I I I I I I II I I I I I I R RAY 2 LAYO T 1'-6" ROOF 2 SECTION �F J MODULE SPECIFICATIONS (24) Trina Solar TSM-250 PD05.05 MODULE WEIGHT: 41 MODULE LENGTH: 64.95 MODULE WIDTH: 39.05 ROOF 2 SPECS RAFTER SIZE: 2X6 NOMINAL RAFTER SPAN: 7' - 3" RAFTER SPACING: 24" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 2 SPECS NUMBER OF MODULES: 4 TOTAL MOD. WEIGHT (Ibs): 164 A RACKING WEIGHT (Ibs): 16.2 ARRAY WEIGHT (lbs): 180.2 ARRAY AREA (sqft): 70.5 ARRAY DEAD LOAD (lbs/sgft): 2.6 NUMBER OF MOUNTS: 6 LOAD PER MOUNT(Ibs): 30 ARRAY AZIMUTH(') 179 ARRAY TILT(-) 20 NUMBER OF FLOORS 1 SYMBOL KEY: ------- RAIL — — — — RAFTERS ROOF FIRE CLEARANCE .............(D STRING CONFIG. o STRUCTURAL UPGRADES E SOLAR MODULE ® MOUNT ® SKYLIGHT ® CHIMNEY c PLUMBING OR ATTIC VENT Cl ATTIC VENT ., ! t t y L;+ REv1EEC) t GR uc��`�^t.; Revievreci BY'� CUSTOMER INFORMATION: RAM SINGH 21398 KRZICH PLACE CUPERTINO, CA 95014 /#2590890 DESIGNED BY: REV #: DATE: PV- 2.1 ANAND S. 1 0 1 5/3/16 UGEVITY INC. 66 FRANKLIN ST SUITE 3100AKLAND, CA 94607 By: MHEINZE Date, Locaton: singn- zaauneu svi sneet size: 1in i IHtSt UKAYVINUb. srtUINUA IIUNs, AND DESIGNS ARE I Ht rKUrMK I r Ur au1.-1r..I. NU 1w Ibrw L-wrlcu UK ustu t-UK UK VVI I H ANY U I HtK wUKn u l ncr<I— l nt srcUlnu rrtwcul run vvrn..n �nc�n.,vc ocov ucvcwrc�vninuui wrc vvrtn lov ��rv�� ELECTRICAL KEY: fi BREAKER —�— SWITCH Q SCREW TERMINAL FUSE • SPLICE EARTH GROUND m CHASSIS GROUND — — — GEC EGC (4) #10 PV-Wire (1) #10 EGC FREE AIR 0 1 STRING OF (2)3 10 MODULES 0 1 STRING OF 0 14 MODULES (4) #10 THWN-2 (1) #10 EGC 1/2" EMT (IF APPLICABLE) MIN. NEMA3R UL LISTED JUNCTION BOX WITH 90'C TERMINAL RATINGS LOCATED ON ROOF SUnGEVITY' GENERATE POSITIVE - G� ■ ■ 4 I O MODULE ELECTRICAL SPECIFIC, ABB PVI-6000-OUTD-US-A RATED WATTS (EACH): 6000 SHORT CIRCUIT CURRENT (Isc): 8.79 AC OPERATING VOLTAGE (V): 240 OPEN CIRCUIT VOLTAGE (Voc): 38 AC OPERATING CURRENT (A): 28 OPERATING CURRENT (IMP): 8.27 NUMBER OF MPPT CHANNELS 2 OPERATING VOLTAGE (VMP): 30.3 INVERTER EFFICIENCY: 0.965 MAX SERIES FUSE RATING: 15 INTEGRATED DC DISCONNECT STC RATING: 250 INVERTER 1 MPPT 1 SPECIFICATIONS PTC RATING: 228 MAXPOWER POINT CURRENT (Imp): 8.3 DESIGN CONDITIONS MAX POWER POINT VOLTAGE (Vmp): 303 HIGHEST 2% DB DESIGN TEMP ('C): 32 MAX SYSTEM VOLTAGE (Voc): 410 MIN. MEAN EXTREME ANNUAL DB ('C): 0 SOURCE CIRCUIT CURRENT (Isc): 11 p MAX SHORT CIRCUIT CURRENT (Isc): 11 INVERTER 1 MPPT 2 SPECIFICATIONS MAXPOWER POINT CURRENT (Imp): 8.3 MAX POWER POINT VOLTAGE (Vmp): 424.2 MAX SYSTEM VOLTAGE (Voc): 574 SOURCE CIRCUIT CURRENT (Isc): 11 MAX SHORT CIRCUIT CURRENT (Isc): 11 (3) #8 THWN-2 (3) #8 THWN-2 (3) #8 THWN-2 (3) #6 THWN-2 (1) #8 GEC (1) #8 GEC (1) #8 GEC (1) #8 GEC 3/4" EMT 3/4" EMT 3/4" EMT 3/4" EMT (N) PVI-6000-OUTD-US-A AC DISCONNECT, INVERTER W/ INTEGRATED 60AMP, NON -FUSIBLE, C-H DC DISCONNECTS DG222URB MPPT 1 LOCUS — AC METER DC . OUTPUT . — LOAD LINE -------- GEC --- --- — —� — ------------------- MPPT 2 INVERTER MAX Voc = 14 x [38V + (38V x-0.0032 x (0°C - 25°C))] = 574VDC Imax = 8.79A x 1 STRING x 1.25 = 10.9875A CONDUIT ELEVATION: 1/2 TO 3-1/2" = 22 °C HIGH AMBIENT TEMPERATURE: 32 °C EXTREME LOW: 0°C ROOFTOP AMBIENT TEMP (Tcorr): 54°C = 0.76 CONDUIT FILL (Cfill): 0.8 CONTINUOUS USE = Imax * 1.25 = 13.73A CONDITIONS OF USE = Imax / Tcorr / Cfill = 11 A/0.76/0.8 = 18.09A CONDUCTOR SIZE FOR 18.09A INSTALLATION SHALL USE MIN. #10 AWG AC Disconnect, 60Amp, Fusible 35A FUSE LOAD LINE U& METER SUPPLY SIDE CONNECTION WITH POLARIS BLOCK OR SIMILAR 250VAC RATED UL LISTED AND APPROVED CONNECTOR 125A MAIN BREAKER 1[ v (E) LOADS (N) 125A MSP (E) LOADS 240V 2P 3-W 1CO I I L--------- I I LU I wl 1NO �F. cy.rd•'" fit iylr.zing v:ml`l'.n� De GEC IRREVERSIBLY SPLI EXISTING GEC OR BONDED DI F i . f • j TO EXISTING GROUNDING ELEC �•-= j L; REVIEWED FaR. CGGE P�?`:ICF Revievred Py:-% 24 MODULES TOTAL 24 x 228(PTC WATTS) x 0.965 = 5280 CEC WATTS PVI-6000-OUTD-US-A MAX OUTPUT CURRENT = 28A BREAKER SIZE = 28A x 1.25 = 35A => 35A CUSTOMER INFORMATION: RAM SINGH 21398 KRZICH PLACE CUPERTINO, CA 95014 /#2590890 DESIGNED BY: IREV #: DATE: PV- 3.0 ANAND S. 0 1 5/3/16 i I IL IUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: MHEINZE Date: Location: Singh - 2590890 SV1 Sheet Size: 11z17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSEN Z 4 NEC 690.5(c) PLACE THIS LABEL ON INVERTER(S) OR NEAR GROUND -FAULT INDICATOR (ON INVERTER(S) U.O.N.) WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.17(E) PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 705.12(D)(2)(b) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE)) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(3) PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES. CAUTION CONTAINS MULTIPLE POWER SOURCES NEC 690.31 (E) 3 & 4; 2012 IFC 605.11.1 PLACE ON ALL JUNCTION BOXES, EXPOSED RACEWAYS EVERY 10' AND T FROM BENDS AND PENETRATIONS, ADJACENT TO THE MAIN SERVICE DISCONNECT WARNING PHOTOVOLTAIC POWER SOURCE NEC 690.35(F) PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED UTILITY DISCONNECT SWITCH INTERACTIVE PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT (A): 28 NOMINAL OPERATING AC VOLTAGE (V): 240 INVERTER 1 MPPT 1 DC DISCONNECT PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT (Imp): 8.3 RATED MAX POWER POINT VOLTAGE (Vmp): 303 MAX SYSTEM VOLTAGE (Voc): 410 SHORT CIRCUIT CURRENT (Isc): 11 INVERTER 1 MPPT 2 DC DISCONNECT PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT (Imp): 8.3 RATED MAX POWER POINT VOLTAGE (Vmp): 424.2 MAX SYSTEM VOLTAGE (Voc): 574 SHORT CIRCUIT CURRENT (Isc): 11 diJftRTlN0 13d'HdKbepartrnent R�Tbr�C`o�f Cb'fliIPLIANCE sunGEVITY° GENERATE POSITIVE' SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: MHEINZE Date:— Location: Singh - 2590890 SV1 Sheet Size: 11z17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT Mono Multi Solutions iwiw"Min PRODUCTS POWER RANGE RONNIE TSM-PD05 250-265W 1 V TSM-PDO5.08 250-265W Tm 11E M TSM-PDO5.05 245-260W 6 Aft CELL MULTICRYSTALLIN.E MOME POSITIVE POWER TOLERANCE As a leading global manufacturer of next generation photovoltaic products, we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able- to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors. and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited , Inas.^l�r.com i scalar Smart Energy Together PD05.08 PD05 P D 05.05 Our most versatile product _ • Compatible with all major BOS components and system designs • 1000V JL/1000V IEC certified One of the industry's most trusted modules �a;o • Field proven performance Highly reliable due to stringent quality control Over 30 in-house tests (UV, TC, HE and many more) "- ° • In-house testing goes well beyond certification requirements ® PID resistant Certified to withstand challenging environmental conditions • 2400 Pa wind load ® 5400 Pa snow Iced DIMENSIONS Of PV MODULE u nit:m m 941 UNCTION BOx ® �. NNAMFPLITE �II I° I C. E043 GROUNDING HOLE A A 1] OflAiN HOLE 812 180 BackView I 35 A=A 10.00 9.00 3.00 7.00 a E.0. sb0 u 400 3.00 z.00 1.00 a.M 0' r-V CURVES OF FV MODULE (26OW) 10 20 - 30 40 - 50 vd.ga lVl ELECTRICAL DATA (STC) Peak PowerWatts-PNwx (Wp) 245 250, 255 260 265 Power Output Tolerance-Pnwx (%) 0 - +3 Maximum Power Voltage-Vwp (V) 29.9 1 30.3 30.5 30.6 30.8 Maximum Power Current-Impp (A) 8.20 8.27 8.37 8.50 8.61 Open Circuit Voltage-Voc (V) 37.8 38.0 38.1 38.2 .38.3. Short Circuit Current-Isc (A) 8.75 8.79 8.88 9.00 9.10 Module Efficiency (%) 15.0 15.3 15.6 15.9 16.2 STC: Irradiance 1000 W/m', CellTemperature 25'C, Air Mass AM1.5. Typical efficiency reduction of 4.59 at 200 W/m' according to EN 60904-1. ELECTRICAL DATA (NOCT) Maximum Power -Pp x (Wp) 182 186 190 193 197 Maximum Power Voltage-VwR (V) 27.6 28.0 28.1 28.3 28.4 Maximum Power Current-Imrv,(A) 6.59 6.65 6.74 6.84 6.93 Open Circuit Voltage-Voc (V) 35.1 35.2 35.3 35.4 35.5 Short Circuit Current-Isc (A) 7.07 7.10' 7.17 7.27 7.35 NOCT: Irradiance at 800 W/m', Ambient Temperature 20°C, Wind Speed 1 m/s. MECHANICAL DATA Solar cells Multicrystalline 156 x 156 mm (6 inches); Cell orientation 60 cells (6 x 10) Module dimensions 1650 x 992 x 35 mm(64.95 x 39.05 x 1.37 inches) Weight 18.6 kg (41lb) Glass 3.2 mm(0.13 inches),High Transmission, AR Coated Tempered Glass Backsheet White(PD05&PDO5.08); Black(PD05.05) Frame Silver Anodized Aluminium Alloy (PD05); Bloc k(PD05.08&PDO5,05) J-Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.Omm' (0.006 inches2),, I000mm(39.37inches) Connector MC4 Compatible TEMPERATURE RATINGS Nominal Operating Cell 44°C (±2°C) Temperature (NOCT) Temperature Coefficient of Pwx 0.41%/°C Temperature Coefficient of Voc 0.32%' °C Temperature Coefficient 0 o05 C WARRANTY ��� ���� 1'0year Product Workmans i rwt 25 year Linear Power Warranty C (Please refer to product warranta- llEWED 1 CERTIFICATION FVIP_.VdE L, E c iIL us PACKAGING CONFIGURATION USTE0 Modules per box: 30 pieces, PV'CYCLE® " ' Modules per 40' container:840 pieces MAXIMUM RATINGS Operational Temperature 40-+85°C Maximum System IOOOV DC(IEC) Voltage IOOOV DC (LIQ Max.Se EuVtp Building Depa t,nent �I N LI a z wl w� CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trin-aSolar ©2015 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice. Smart Energy Together R CODE COMPLIANCE 8y. -- : CERTIFICATE OF COMPLIANCE Certificate Number 20140630-E306515 Report Reference E306515- 20121213 Issue Date 2014-JUNE-30 Issued to: TRINA SOLAR LTD 2 TIAN HE RD, ELECTRONICS PARK NEW DISTRICT, CHANGZHOU, JIANGSU 213031 CHINA, This is to certify that PHOTOVOLTAIC MODULES AND PANELS WITH representative samples of SYSTEM VOLTAGE RATINGS OVER 600 VOLTS Refer to addendum page for Models Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 1703 - Standard for Safety for Flat -Plate Photovoltaic Modules and Panels and ULC ORD/C1703-01 - Flat -Plate Photovoltaic Modules and Panels. Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow -Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with "C" and "US" identifiers: 4L lls the word "LISTED"; a control number (may be alphanumeric) assigned. by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20140630-E306515 E306515-20121213 2014-JU NE-30 The modules with the specified construction as below may be marked with its type for UL listed fire performance products only as the below table: Module model Specific construction Marking TSM-xxxPD05, Superstrate: 3.2-4.36mm thick; Module Fire TSM-xxxPD05.08 EVA: 0.25-0.61mm thick; Performance: Substrate: 0.30 mm - 0.64 mm Type 1 thick; Frame: Cross sectional dimension: 35 x 35mm, Height: 35mm, Thickness: 1.5mm TSM-xxxPD05, Superstrate: 3.2-4.36mm thick; Module Fire TSM-xxxPD05.05, EVA: 0.25-0.61mm thick; Performance: TSM-xxxPD05.08 Substrate: 0.284 mm - 0.30 mm Type.2 thick; Frame: Cross sectional dimension: 35 x 35mm, Height: 35mm, Thickness: 1.5mm TSM-xxxPD14, Superstrate: 3.2-4.36mm thick; Module Fire TSM-xxxPD14.08 EVA: 0.25-0.65mm thick; Performance: Substrate: 0.284 mm - 0.300 mm Type 8 thick'; Frame: Cross sectional dimension: 40*35 mm, Height: 40mm, �, t °F Thickness: 1.5 mmg �_.., TSM-XXXPD05.10 Superstrate: 3.2-4.36mm i E' Moduie-tl i_Te TSM-XXXPD05.18 EVA: 0.25-0.65 mm thick Perf,ormance:,q Substrate: 0.025 - 0.28 a Type 5i3 ,, ,� thick; Frame: REVIEWED FOR CODE COMPLIANCE Cross sectional dimension: 40* 38 mm, Revi wed By. JG � Height: 40mm, Thickness: 1.8mm William R. Carney, Director, North American Certification Programs William R. Carney, Director, North American Certification Programs UL LLC _ L UL LLC - - L Any information and documentation involving UL Mark services am provided on behalf of UL. LLC (UL) or any authorized licensee of UL. For questions, please - Any Information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions,. please contact a local UL Customer Service Representative at-ul.com/contactus - contact a local UL Customer Service Representative at v .ul.comfcontactus Page 1 of 4 Page 3 of 4 Designed for residential and small commercial PV installations, this inverter fills a specific niche in the ABB product line to cater for those installations producing between 5kW and 20kW. This inverter includes dual input _ section to process two strings with independent Multiple Power Point Tracker (MPPT). The high-speed and precise MPPT algorithm offers real-time power tracking and energy harvesting. Flat efficiency curves ensure high -efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. The wide input voltage range makes the inverter suitable for low -power installations with reduced string size. The transformerless operation offers high performance efficiencies of up to 97.1 percent. Free remote monitoring capability is available with every installation. This enables homeowners to view their energy production and offers installers a proactive and economic way of maintaining and troubleshooting the system. Highlights: — Single-phase and three-phase output grid connection — Wide input range for increased stringing flexibility — The high-speed and precise MPPT algorithm offers real-time power tracking and improved energy harvesting — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental condition — Integrated DC disconnect switch in compliance with international Standards (-S Version) Additional highlights - RS-485 communication interface (for connection to laptop or data logger) - Available with the optional VSN300 Wifi Logger Card for easy and affordable wireless monitoring - Compliant with NEC 690.12 when used with ABB's Rapid Shutdown device - Comes standard with DC Arc Fault Circuit Interruptor (AFCI) to comply with NEC 690.11 Technical data and types Tvoe code PVI-5000-OUTD-US PVI-6000-OUTD-US General Specifications Nominal output power 5000W 6000W .......................................................................................................................................................................................................................................................................................................................................................... _ Maximumoutput.. ...............................................................................€.............................................5000W..............................................i.............................................6000W Rated grid AC voltage 208V 240V 277V 208V 240V 277V Input side (DC) , ....................................... :........................ .......................................................................... Maximumusable power for each channel.........................................................................................................................................4000W..................................................................................................... :...................................................................................................................................................................................................... ............... - Absolute maximum voltage (Vmax) 600V Start-uP.._voltag.e.. start)....................................................................................................................................................................200V ......................................................................................................................................................... ........................ ............. ........... (adj. 120 350)....................................................................................._ Full power MPPT voltage range.......................................................................................................145-530V......................... i 175-530V Operating MPPT voltage range ................................................................................................................................................................................................................................................................................................................................................................... 0.7 x Vstart - 580V (-a90V) Maximum current (Idcmax) for both MPPT in parallel i 36A ......................................................................................................... Maximum usable current per channel ......................................................................................................................................................................................................................... 18A ............ ................................................. ............................................................................: Maximum short circuit current per channel .......................................................................................................................................................... .............................................................. 22A... ....... .......... ....... ........................ ................. ..... ...................... .... .. ..............................................'ai'........'e'r.................................................................................................................................................................................. Number of wire landing terminals per channel a'i'... 2 Pairs Array wiring termination Terminal block, pressure clamp, AWG20-AWG6 Output side -(AC) -., . Grid connection pe ............................................................................................:. 10/2W Split-0/3W € 10/2W 10/2W S lit 0/3W 10/2W ..................................................................................................................................... P....-...................................................._ Adjustable voltage range (Vmin-Vmax) 183-228V 221-264V 244-304V 183-228V 211-264V 244-304V .Grid frequency.........................................................................................................................................................................................................60H......................................................................................................._ ............................................................................................................................................................................................... Adjustable grid frequency range...............................................................................................:. 57-60.5Hz ............................................................................................................................................................ I ..................... Maximum current (le°,m�).pa... 27A Power factor .........................23A.............i.............20A.............i.............30A.............f.............28A.............[.............24A................ ....... > 0.995..(adjustable to ±0.8) ........................................................................................................................ distortion at rated power .........................................................................I................._ �%....................................................................................................._ ..Total.harmonic .............................................................................................................................................�. Contributory fault current' 36.25 APk/ 36.5 APk/ 31.75 APk/ 36.25 APk/ 36.5 APk/ 31.75 Apk/ .............................................................. 25;63AR...........25.81.Aa�...........22:45AR.......i......25:63AR............25;81AR.............22.45AR....._ Grid wiring termination type Terminal block, pressure clamp, AWG20-AWG4 Input:_ Reverse olarit protection P............Y......................................................................................................................................................................................................................................................................................................- Yes Over-voltage protection type .................................................. Varistor, 2 for each channel..................,....s ........................ PV array ground fault detection i Pre start-up R and dynamic GFDI (requirjes JlcWp y 11 Output >. ; .., •::: ..Anti -is landing protection ........................................................................................................................................................................................... Over -voltage protection type M eJI� IEEE1547 req 'r r'1i"il n .. .................................................................................. r - 2 (L, - Lx .................................................................................................................................................................................... Maximum AC OCPD rating ............ 35A [ 36A 6; { 40A _ _ .35A 30A Efficiency 61 ) Maximum efficiency Gr1' 97.1 %" ............................... .... ....................................................................................................................................,........................................................... CECefficiency................................................................................................ ...... 96%........................96.5%............................ 0 96%....... 96.5% %.........._ ........ ............. .............. .. . . 6.5 .... ...................................... User interface Gra hi disp Operating, performance,, r , Stand-by consumption <8W —� s ...................................................................._......................................................runs............... Nighttime consumption .......................................... ......... ........................................... <0.6W°„° f�oyiP.�1V�C� �if�$ Communication _ User-interface 16 characters x 2 lines LCD display.................... ................................................_................................................................................ Remote monitoring (1xRS485 incl.) ................................................................................................................................. ...... VSN700 Data Logger (opt.), VSN300 Wifi Logger Card (opt.) Environmental Ambient air operating temperature range ...........................................................................................................................................................................................................................................................................Berating,C)....................... -13°F to +140°F (-25°C to +60°C) 13°F to +140°F (-25°C to +60°C) with Ambient air storage temperature ran e ................................. ................9....................................................................................................................................................................................................................................................................... -40°F to +176°F (-40°C to +80°C) [ -40°F to +176°F (-40°C to +80°C) Relative humiditY........................................................................................................................... .-100% RH condensin9.............................................................-100% RH condensin9............................ Acoustic noise emission level ......................................................................................................................................................................................................................................................................................................................................... < 50 db (A) Q1 m < 50 db (A) ®1 m Maximum operating altitude without derating _ 6560ft (2000m) 6560ft (2000m) .......................................................................................................................................................................................................... 2 ABB solar inverters I Product flyer for PVI-5000/6000-TL-OUTD Block diagram of PVI-5000/6000-TL-OUTD MPPT 1 INVERTER i I ' (DC/DC) BULKCAPS (DC/AC) I / ' + + LINE GRID PARALLEL FILTER RELAY INl INl IN1 IN1 —II' I—✓��--• ' L1 31 1 N TDC-1-------- L2 + � AFDI I ' IN2 ' MPPT2 T IN2 IN2 ' (DC/DC) L$ I � +i ' ' IN2 , RESIDUAL CURRENT 1-A VERSION STANDARD VERSION DETECTION 1T ft5485 - +T/R = DDC/AC RTN DSP ' DSP DSP --_!_______ __ _____i_____ C__________- CONTFL CONTR. REMOTE CONTROL•, R I GROUND Pr FAULT DETECnON - ALARM N.0 I CONTROL CIRCUIT N•0 C 'Remote control function not available on -Aversion PVI-5000/6000-OUTD-US • ®®s®® 0 ®-®�-®® 0 10 20 30 40 50" 60 A) bu YU 1UU ` % of Rated Output Power Technical data and types pa a Wit- 250 10% 20% 30% 50% 75% 100% %of Rated Output Power" PVI-5000/6000=OUTD-US ' 480 97: 96,5 400 x t : 96,2 95,9 95,6 95,3 345 MPPT 95 Voltage - 94,7 �_ ¢ 94,4 94,1 393;8 00 93,5 93,2 19219 92,6 Type code PVI-5000-OUTD-US PVI-6000-OUTD-US -Mechanical specifications Enclosurerating........................................................... I .............. ..................................... NEMA 4X Cooling Natural convection Dimensions H x W x D 41.4x12.8x8.6 in (1052 x 325 x218 mm) ................................................................................................................... Weight ...................... ........................................................................................................................................................................................................................ ................................................................................................................................................................ <59.51b (27.Okg).......................................................................................... ShI.P..Ping wei.g.ht........................... ................................................................................. <781b(35.4kg)............................................................................................. Mounting system Wall bracket .................................................................................................................................................................................................................... Trade size KOs: (tea x 1/2") Conduit connections ..................................................... 3..places..sidel..front,..rear).......................................................... DC switch rating (per contact) 25A / 600V Safety and Compliance. Safety and EMC standard 15 Class B ............................ ........................................................................................................... .................................................................................... ....................................................................................................................................... Safetyapproval.................................................................................................................................... . .CSA,a Regional Compliance Rule 21, HECO, NEC 2014 690.11. NEC 690.12 with ABB Rapid Shutdown device . ; .. ....... .,.. , ... .......,. ...... ..... . Available models :,......: Wfh DC sw'iitch, wiring box and -arc fault detector and interru ,tor PVI-5000-OUTD USA PVI-6000-OUTD-US-A P...............................................................................................................................................................................................................................:...............................................................................................-............ All data is subject to change without notice Product flyer for PVI-5000/6000-TL-OUTD I ABB solar inverters 3 �-AIM CSA 'Group Certificate of Compliance Certificate: 2708417 Project: 70020581 Issued to: ABB, Inc. 16250 W. Glendale Drive New Berlin, WI 53151 USA Master Contract: 259813 Date Issued: January 14, 2015 The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: P", Rob Hempstock, AScT. C US Authorized by: Ernesto Lopez Operations Manager ' O 1111011101E.y CLASS 531109 - POWER SUPPLIES - Distributed Generatio er-�ystems Equipn e%tJPERTI N CLASS 5311 89 - POWER SUPPLIES - Distributed Generation �o> to `systems Equip tt tthg Depart Mnt - Certified to U.S. Standards .� . Utility Interactive Inverter, Models PVI-5000-OUTD-US, PVI-5 ©_? ( -US =A,"P6000-OOTD-US, PVI-6000-OUTD-US-A, and PVI-6000-OUTD-US-W, permanen y connected. Off;?L;At�lCE REVIEWED I=OR CODE C Notes: 1. All above models in this series may include expansion board wfa�9919ss Mennae option and will be identified with model designation including 11-Zt1 suffix at the end. 2. Models PVI-5000-OUTD-US-A and PVI-6000-OUTD-US-A are provided with PV DC ARC -Fault Circuit Protection for series arcing faults. 3. All above models in this series assembling the revenue grade meter, RGM-MODULE-US, will be identified with model designation including 11—M" suffix. The RGM-MODULE-US meter has been evaluated for safety only and not for performance. 4. All the above model numbers may include the "-S" designator, which is for marketing purposes only. 5. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record or the Certificate of Compliance Annex A. °'". I RON RI DGE Roof Mount System p* n' rsn >, •�..�. ,_.. -ate o-e.� { t Built for sola€r's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested L"1i�° All components evaluated for superior ' structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Integrated (grounding UL 2703 system eliminates separate module grounding components. PE Certified Pre -stamped engineering letters available in most states. Design Software Online tool generates a complete bill of materials in minutes. 20 Year Warranty Twice the protection offered by competitors. AUTHORIZATION TO MARL{ j This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be 1, applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: IronRidge, Inc. Address: 1495 Zephyr Ave Address: 1435 Baechtel Road Hayward, CA 94544 Willits, CA 95490 Country: USA Country: USA Contact: Yann Schwarz Contact: Jim Norsworthy Phone: (800) 227-9523 Phone: (800) 227-9523 (510) 225-0973 FAX: (707) 459-1833 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Email: jorswothy@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Q Report Issuing Office: Lake Forest, CA Control Number: 4007559 Authorized by: for Thomas J. Patterson, Certification Manager ETL CLASSIFIED° } i' l us �isreu Intertek ------- --- .-.-. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-43 - ,Q a, 312-283-1672 p `s e UL Subject 2703 Outline of Investigation for Ra oit7g`Systems anAl ii1lQiA1_ 1� ce`sVAt-Plate Standard(s): Photovoltaic Modules and Panels, Issue Numb Octob,r 4, 2010 LA Product: XR Rails with Integrated Grounding. °t �i i� `' "i'VJ Brand Name: N/A Models: 51-61GD-005, 51-61GD-005B, 51-5000-001, an -Q 1 r, r)p 'I = t f7it/iPi_IA Reviewed BY: ��✓" 7/ ATM for Report 101541132LAX-002 Page 1 of 3 ATM Issued: 10-Nov-2014 ED 16.3.15 (Wan-13) Mandatory a .as-,.4 waul�....a.a...+.».;�.... ° 3:.o„xm=....... .L..:- .....-ror.�... �..s-......a .u.c.. '.,.s.....id........y. I /&/ �\_ IRONRIDGE ipiefied Grounding For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. Integrated Grounding System Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array. ... ti `�'" r e' �= 43 Grounding Strap Grounding Straps are used to- :! f bond rail -to -rail connections. Grounding Lug kThey are only required on the rail with the grounding lug. A single Grounding Lug % connects an entire row of PV modules to the .� grounding conductor. Installation Overview [i] Install Roof Attachments • Install appropriate roof flashing and/or standoff for roof type Attach L-Feet to flashing or standoff. Prepare Rail Connections Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. i Mount & Ground Rails i.c� • Attach rails to L-Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor. Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. l e� Module Frame Compatibility A dale" -frames whose parameters are not �itd i� e provided table have noL pgee��testedyfdc-gp up&t bitity� Li�d�tr L} Y �? ,dewed The Grounding Clart�ip has proven robust in grounding 60-cell and 72-cell solar module frames with box construction and a range of anodization thicknesses. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to 3ronridge,00 Ag ension,. ` �o3t0�mYm-51.Omm rf A B t, � � �•_ ;; 5.`Q8mm (minimum) sm_4 i E Starling Madison Lofquist, Inc. Consulting Structural .and Forensic Engineers 5224 South 39" Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com IronRidge December 18, 2014 1495 Zephyr Ave Page 1 of 20 Hayward, CA 94544 Attn: Mr. David F. Taggart, Vice President Products Subject: IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Dear Sir: We have analyzed the IronRidge XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures California Building Code 2012 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC-ES Aluminum Design Manual, 2010 Edition The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A — attached. The rails are clamped to aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail not come into contact with the roof. The effect of seismic loads (for all design categories A-F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables IA-9A are for modules with a maximum long dimension of 67.5 inches and Tables 1B-9B are for modules with a maximum long dimension of 78.5 inches. Rim Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis December 18, 2014 Page 5 of 20 Table 4A - MAXIMUM SPANS (in) - Roof Slope 7° to 27' - Wind Zone 1 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 1 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 75 65 55 49 43 39 35 33 31 29 Category B 130 75 65 55 49 43 39 35 33 31 29 140 71 65 55 49 43 39 35 33 31 29 150 66 65 55 49 43 39 35 33 31 29 160 62 62 54 48 43 39 35 33 31 29 170 59 59 53 47 43 1 39 35 33 1 31 29 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 1 75 65 1 55 49 43 39 35 33 31 29 120 70 65 55 49 43 39 35 33 31 29 Category C 130 65 64 54 48 43 39 35 33 31 29 140 60 60 53 48 43 39 35 33 31 29 150 56 56 52 47 43 39 35 33 31 29 160 53 53 51 46 42 39 35 33 31 29 170 50 50 50 45 41 38 35 33 31 29 100 75 65 55 49 43 39 35 33 31 29 105 73 65 55 49 43 39 35 33 31 29 110 70 65 55 49 43 39 35 33 31 29 120 64 64 54 48 43 39 35 33 31 29 Category D 130 60 60 53 47 43 39 35 33 31 29 140 55 55 52 46 42 39 35 33 31 29 150 52 52 1 50 1 46 42 39 35 33 31 29 160 49 1 49 49 45 41 1 38 35 1 33 1 31 29 170 46 46 46 44 40 1 37 35 1 33 1 31 29 Notes — see page 20 Starling Madison Lofquist, Inc. -5- Eli REVIE r01 :. _ .... Reviewer .- Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis December 18, 2014 Page 6 of 20 Table 5A - MAXIMUM SPANS (in) - Roof Slope 7'to 27'- Wind Zone 2 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 72 65 55 49 43 39 35 33 31 29 105 69 65 55 49 43 39 35 33 31 29 110 66 65 55 49 43 39 35 33 31 29 120 60 60 55 49 43 39 35 33 31 29 Category B 130 56 56 55 49 43 39 35 33 31 29 140 52 52 52 49 43 39 35 33 31 29 150 49 49 49 49 43 39 35 33 31 29 160 46 46 46 46 43 1 39 35 33 31 29 170 43 43 1 43 43 43 39 35 1 33 31 29 100 61 61 55 49 43 39 35 33 31 29 105 58 58 55 49 43 39 35 33 31 29 110 56 56 55 49 43 39 35 33 31 29 120 51 51 51 49 43 39 35 33 31 29 Category C 130 48 48 48 48 43 39 35 33 31 29 140 44 44 1 44 44 43 39 35 1 33 31 29 150 41 41 41 41 41 39 35 33 31 29 160 39 39 39 39 39 1 39 35 33 31 29 170 36 36 36 36 36 36 35 33 31 29 100 56 56 55 49 43 39 35 33 31 29 105 54 54 1 54 49 43 39 35 33 31 29 110 52 52 52 49 1 43 39 35 1 33 31 1 29 120 47 47 47 47 43 39 35 33 31 29 Category D 130 44 44 44 44 43 39 35 33 31 29 140 41 41 41 41 41 39 35 33 31 29 150 38 38 38 38 38 38 35 33 31 29 160 36 36 36 1 36 36 1 36 1 35 33 31 29 170 33 33 33 1 33 33 1 33 33 33 31 29 Notes — see page 20 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis December 18, 2014 Page 7 of 20 Table 6A - MAXIMUM SPANS (in) - Roof Slope 7' to 27° - Wind Zone 3 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 59 59 55 49 43 39 35 33 31 29 105 56 56 55 49 43 39 35 33 31 29 110 54 54 54 49 43 39 35 33 31 29 120 49 49 49 49 43 39 35 33 31 29 Category B 130 46 46 46 46 43 39 35 33 31 29 140 42 42 42 42 42 39 35 33 31 29 150 40 40 40 40 40 39 35 33 31 29 160 37 37 37 37 37 37 35 33 1 31 29 170 35 35 1 35 35 1 35 35 35 33 31 29 100 50 50 50 49 43 39- 35 33 31 29 105 48 48 48 48 43 39 35 33 31 29 110 45 45 45 45 43 39 35 33 31 29 120 42 42 42 42 42 39 35 33 31 29 Category C 130 39 39 39 39 39 39 35 33 31 29 140 36 36 36 36 36 36 35 33 1 31 29 150 33 33 33 33 33 33 33 33 31 29 160 31 31 31 31 31 31 1 31 31 31 29 170 29 29 29 29 29 29 29 29 29 29 100 46 46 46 46 43 39 35 33 31 29 105 44 44 44 44 43 39 35 1 33 31 29 110 42 42 42 42 42 39 35 33 31 29 120 38 38 38 38 38 38 35 33 31 29 Category D 130 35 35 35 35 35 35 35 33 31 29 140 33 33 33 33 33 33 33 33 31 29 150 31 31 31 31 31 31 31 31 31 29 160 29 29 29 1 29 29 29 1 29 29 29 29 170 27 27 1 27 1 27 27 27 1 27 27 27 1 27 Notes — see page 20 Building Department -_VIEWED FOR CODE COMPLIANCE Reviewed By: Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -6- -7- IronRidge December 18, 2014 Mr. David F. Taggart Page 20 of 20 IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Notes — Tabulated values are based on the following criteria: l . Building mean roof height = 30 ft 2. Risk Category I 3. Solar maximum module long dimension is 67.5 inches for Tables 1A-9A and 78.5 inches for Tables 1B-913. 4. Provide 2 in. clear between roof and rail 5. End cantilever span (max) = 0.40 x maximum span from above tables 6. No rail splices in end spans 7. No rail splices in middle 1/3 of interior spans 8. Single simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans. Our analysis assumes that the rails, including the connections and associated hardware, are installed in a workmanlike manner in accordance with the "IronRidge Roof Mount Installation Manual' by IronRidge and generally accepted standards of construction practice. Additional information is available at the IronRidge web site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager �� 1ae4 t ?1 -•NI �!/_: t% i 41-, EXP. f , Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -20- 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com ``W (a F �I I do a 11 {0 .l1 ; On`li Cce n rcl .1 -_€�"'0 1'-, In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. pplicant Name & Address: Product Description: Ratings & Principle Characteristics: Models Brand Name: Relevant Standards: Verification Issuing Office: IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA XR Rails with Integrated Grounding. Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope appiications when using Type 1, 2 and 3, Fisted photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by manufacturers installation instructions. No perimeter guarding is required. „ I' 51-61GD-005, 51-61GD7005B, 51-5000-001 and 51-65-001 IronRidge Roof Mount UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL17033hird Edition dated Nov. 18, 2014, (Section 31,2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): II 101769343MID-001rl, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1=cr1. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chad Naggs Reviewed by —Gregory Allen Title: Technician 11, Fire Resistance Title: t vw Engineering Team l ea f}Fire Resistance ma Signature:- Signatu ems- - e� Date: 03/30/2015 Date; ' 03/,30/2015 - OI�I� r'� JR CODE C This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) E-Mount Lag I QMSE - LAG THIS EDGE TOWARDS ROOF RIDGE 9.00 PROPRIETARY AND CONFIDEMML ME INFORMAIION CONTAINED W THIS DRAWING IS THE SOLEPROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PA A WHOLE WRHOUT THE WRITTEN PERM SION OF QUICK MOUNT PV IS PROW M. 5 1 4 ITEM DESCRIPTION QTY./BOX NO. 1 FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CLASSIC, A360.1 CAST AL, MILL 1 3 PLUG, SEALING, 5/16" X 7/8", EPDM / 18-8 SS 1 4 LAG SCREW, HEX HEAD, 5/16' x 5-1 /2", 18-8 SS 1 5 IWASHER, FENDER, 5/16" ID X 1-1 /4" OD, 18-8 SS 1 Quick Mount P` .......... TITLE: QMSE-LAG: QMPV E-MOUNT AVAILABLE IN MILL, AND WITH LAG BOLT 3RONZE ANODIZED FINISHES UNLESS OTHERWISE SPECIFIED: -. SIZE DRAWN BY: DFM REV DIMENSIONS ARE IN INCHES I TOLERANCES: A i DATE: 8/29/2014 FRACTIONAL! 1/8 TWOPLACEDECIMAL 2.18 DO NOT SCALE DRAWING 1 THREE PLACE DECIMAL !.125 SCALE: 1:3 1 WEIGHT: 0.96 :SHEET 1 OF I 3 -- - - 2 -- - —_..-- Lag pull-out ..capacities Lag Bolt Specifications Specific Gravity 5/16" shaft per 3" thread depth 5/16" shaft per 1" thread depth Douglas Fir,.Larch .50 798 266 Douglas Fir, South .46 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f S higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A Notes: 1)Thread must be embedded in a rafter or other structural roof member. 2) See NDS Table 11.5.1 C for required edge distances. quickMount . RESPECT THE ROOF E-Mount Lag Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" long -style bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be Carefully lift composition roof shingle with roofing Insert flashing between 1 st and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove nails up so top edge of flashing is at least 3/4" higher mounts will be placed. as required. See "Proper Flashing Placement" on than the drip edge of the 3rd course and lower next page. flashing edge is above the drip edge of 1 st course. Mark center for drilling. Using drill with 7/32" bit, drill pilot hole into roof and rafter, taking care to drill square to the roof. Do not use mount as a drill guide. Drill should be 'long style bit, aka 'aircraft extension bit'to drill a 13/4" deep hole into rafter. Clean off any sawdust, and fill hole with sealant Slide the flashing into position. Insert the rubber compatible with roofing materials. plug into the QBlock cavity. Slide the Washer and the L-foot (not included) onto Using a 1/2 inch socket on an impact gun drive the lag screw. the lag screw until the QBlock stops rotating easily. DO NOT over -torque. BI 7.2.3-31 Sep-2014, Rev 1 BI 7.2.3-31 Sep-2014, Rev 1 Product Datasheet ENERGY The LGate 120 combines a revenue -grade, solid-state power meter with an advanced communications gateway. These components work in conjunction to remotely monitor the performance of residential solar energy installation regardless of panel or inverter type. The LGate 120 is a one-piece completely under glass meter which installs easily using a standard socket base. Performance data is uploaded in near real-time to the Locus Energy SolarOS monitoring platform which provides a suite of tools and analytics for asset managers. DATA COLLECTION AC energy data is collected by the meter and passed to the communications module. Additional system performance data can be collected directly from meteorological sensors and supported inverters via available RS-485 or Zigbee connections. All data is stored in non-volatile memory and then automatically uploaded to the SolarOS and SolarNOC platforms. NETWORK CONNECTIVITY The communications gateway inside the LGate 120 supports plug and play connectivity through a cellular or available Ethernet network connection. Once the unit is installed and powered on, it will immediately begin transmitting data without any configuration. For maximum reliability, the communications gateway will automatically route uploads between the wireless and wired connections if either of the networks are unavailable. FEATURES • ANSI C12.20 power meter • RS-485 and Zigbee inputs • GSM cellular or Ethernet connectivity • Over the air firmware updates • Easy, low cost installation • Doesn't require entrance into the building • Plug and play activation • LCD display DIAGRAM - TYPICAL CONFIGURATION INTERNET ®i MWO -Mii "isRE �ii ®i 1711111ili- ® i. E< ®® ®1 INVERTER(S) LGATE 120 PV ARRAY DIMENSIONS SOCKET METER 6.95 in 6.31 in J1 SPECIFICATIONS Shielded CATS ELECTRICAL SERVICE —5.46in—� — 6.00 in ► 7.30 in — •• •. Processor ARM9 embedded CPU Accuracy ANSI 12.20 (Class 0.2%) OS Custom version of Linux 2.6, OTA firmware updates Voltage Inputs 120 - 480 VAC Memory 128 MB RAM Max. Current Input 200 A Display LCD screen Service Type Single phase , 60 Hz Socket Type 2S Enclosure NEMA 3R Type Weight 8 oz Dimensions 6.95" x 6.5" x 7.3" Environment -20 to 60C, all-weather Warranty 5 year limited warranty COMMUNICATION Model Number OPTIONS Wate120-3Q Wate120-3Gy LGate120-36z Cellular - 3G GSM ✓ ✓ ✓ RS-485 2 and 4 wire ✓ Modbus J Zigbee Ethernet RJ-45 10/100, DHCP/Static ✓ COMPLIANCE ANSI 12.20 class 0.2% FCC Part 156 P tTn._ C U P E R i ' A 7F et'CoApliance R onarTfslent REViF.VI,/IwLj FOR %>ii:',` E PL.! ANC;r Re` iF.. 4ed By -r l;�r Single Meter Sockets -Without Bypass 125 & 200 Amp 011 (closed) U204(open) Application • Single meter position • Receive ANSI C12.10 watthour meters • Surface or flush mount (see chart) Construction • Ring type • NEMAType 3R UL • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards Accessories • UL 414 Listed • 5th Jaw Kit - 50365 • ANSI C12.7 • 200ATriplex Ground - ETB200 • AW Hub Single Meter Sockets -Without Bypass 011 F - Flush Mount (U) 204 MS68 - 2" Conduit Hub (U) 207 MS68A - MS73 + MS68 927 MS73 - AL Screw Type Ring SF - Semi Flush Mount SS - Stainless Steel ParWPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral 78205142000 011 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142040 011 F 125 4 10/3W 01-1/1-113 #14 - 2/0 #14 - 2/0 #14 - 210 78205142045 011 MS73 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142050 011 SF 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205144030 927 100 7 30/4W OH/UG #14 -1/0 #14 -1/0 #14 - 2/0 78205156000 204 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78,205156020 204 F 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156030 204 F MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156040 204 MS68 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 35bMCM 78205156035 204 MS68A 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205108490 204 MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156005 U204 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156045 U204 F 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156060 U204 F MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156070 U204 MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156140 U207 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 78205156170 6207 F 200 7 30/4W UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 78205156180 U207 MS73 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM Part/UPC Catalog Overall Dimensions Top Knockout Number Number Height Width Depth Provision Layout 78205142000 011 12" 8" 45/a" AW Hub Fig. 1. 78205142040 011 F 12" 8" 45/9" 2" max KO Fig. 1 78205142045 011 MS73 12" 8" 45/s" AW Hub Fig. 1. 78205142050 011 SF 12" 8" 45/8" 2" max KO Fig.1 78205144030 927 17" 8" 45/3" AW Hub Fig.1 78205156000 204 15" 8" 45/3" AW Hub Fig. 2 78205156020 204 F 15" 8" 6" 2" max KO Fig. 2 78205156030 204 F MS73 15" 8" 6" 2" max KO Fig. 2 78205156040 204 MS68 15" 8" 45/8" AW / 2" Hub Fig. 2 78205156035 204 MS68A 15" 8" 45/8" AW / 2" Hub Fig. 2 78205108490 204 MS73 15" 8" 45/8" None Fig. 2 78205156005 U204 15" 12" 45/9" None Fig.3 78205156045 U204 F 15" 12" 6" (2) 2" max KO Fig. 3 78205156060 U204 F MS73 15" 12" 6" None Fig. 3 78205156070 U204 MS73 15" 12" 45/a" None Fig. 3 78205156140 U207 18" 12" 5" AW Hub Fig. 4 AIC Note: 78205156170 U207 F 18 12" 5" 21/2" max KO Fig. 4 For short circuit current 78205156180 U207 MS73 18" 12" 5" AW Hub Fig. 4 ratings see page 131. B-Line by ffaf® Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 5 Meter Mounting Equipment Knockout Layouts Fig. 1 Top Provision 4F 4F both sides O 1A Fig. 3 Top Provision 4F 4G 4F des . O 4G 1W 125 & 200 Amp 1W=i/4' 1 A = 1/2° 2A = 1/2" - 1/4' 4F=2"-11/2°-11/4°-1° 4G=21/2'-2" 11/2°-11/4' Top Provision = See Chart Fig. 2 ,i Top Provision 0 4F 4F both sides 4F 1A Fig. 4 Top Provision s } 4G 4G L F0(' ; �r C r 'r: jGS otth-- - f sides .... 4G 2A Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment L LPZ� n rlt B-Line by ff.,T-Pj I ■ 3�% ■ LW CIM ®s ENERGY October 22nd, 2013 This letter is to certify that the I -Gate 120 and LGate 320 are communication boards built into the Vision Meter 2S CL200 and 16S CL320 socket meters, respectively. Each of these meters was certified to the ANSI C12.20 (class 0.2%) standard by Underwriters Laboratory on June 7, 2013 as part of the Vision Meter Family (Project Number 12CA71134, Job Number 1001541515, and Report Number R12CA71134- ANSI). ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility and PV monitoring applications. These tests cover both meter accuracy as well as several safety standards including electrical and environmental safety, as well as resistance to various types of mechanical shock. As electrical socket meters are generally installed and maintained by trained and certified professionals, rather than consumers, they do not fit the typical criteria for additional types of UL or IEC certification. If you have any further questions regarding the product certification of any Locus Energy I -Gate -branded device, please contact us at support@locusenergy.com. The Locus Energy Team o' �{ _:idi g UC. [I�CFIIt REVIE Locus Energy, LLC www.locusenergy.com Classic Conduit Composition Mount I QMCC TI I I C GI' 17 TP\RA/A 0r C 0/l/1C DIM/ C: .79 PH EINFOR AND CONfI INEDIN THEINFORMATIONCHE WRRTDINRMISSI NOF LSTHE SOLE T OP5 PROFOUICKMOUMPV. ANY REPRODUCTION IN PART OR /3 A WHOLE WITHOUT THE WRRTEN PERMISSION OF QUICK MOUNT PV 6 PROHIBITED. 5 4 ITEM NO. DESCRIPTION QTY. I FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CONDUIT, 5/16", 6061-T6, MILL 1 3 WASHER, SEALING, 1/4" ID X 7/8" OD, EPDM 1 BONDED SS 4 LAG SCREW, HEX HEAD, 1 /4" x 2-1/2", 18-8SS 1 AVAILABLE IN MILL, CLEAR ANODIZED, AND BRONZE ANODIZED FINISHES. mounr rv- TITLE: QMCC: CLASSIC CONDUIT COMPOSITION MOUNT 'uNLesso!HtrcwrstSrtcrleu 1 SIZE ° DRAWN BY RAD I REV DIMENSIONS ARE IN INCHES TOLERANCES: A DATE 9/24/2013 4 ....._ ...._....._ FRACTIONAL_ 1/8 DO NOT SCALE DRAWING TWOPLACEDECIMAL 2.18 f"""_....._.. ,. .._.. ..,_ .._... _. ... THREE PLACE DECIMAL 2.125 ! SCALE: 1:3 I WEIGHT:0.69 SHEET I OF I 3 2 1 Lag pull-out (withdrawal) capacities (Ibs) in typical lumber: Lag Bolt Specifications Specific Gravity 1/4" shaft per 1 3/4" thread depth 1/4" shaft per 1" thread depth Douglas Fir, Larch .50 393 225 Douglas Fir, South .46 353 202 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 353 202 Hem, Fir .43 313 179 Hem, Fir (North) .46 353 202 Southern Pine .55 455 260 Spruce, Fine, Fir .42 302 173 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 393 225 Sources: American Wood Council, NDS 2005,Table 11.2 A,11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See IBC for required edge distances. IMPORTANT: To maintain waterproofing it is important that the aluminum flashing (item 1) is properly placed under one full course above the mounting block with at least some of the flashing extending up under the course above that — wall Cap in0rl Irtinnt nn hark Classic Conduit Mounting Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun,1 tube of appropriate sealant, drill with 1/8" bit, drill or impact gun with 7/16" deep socket. WARNING: Quick Mount PV products are NOT designed for and shoUld NOT be used to anchor fall protection equipment. Choose placement of conduit mounts along path Lift composition roof tile with roofing bar, just Slide conduit mount into desired position. Remove of conduit. Select location over center of rafter. above placement of conduit mount. any nails that conflict with getting the mountflush with front edge of shingle course. Mark cernter for drilling. Using drill with 1/8" long bit, drill pilot hole into roof and rafter, taking care to drill square to the roof. Insert lag through hole in block, and position clamp over conduit. Using drill with 7/16" socket, drive lag until block is tight. quick Mount PV RESPECT THE ROOF BI 7.2.3-8 Aug-2014, Rev 4 BI 7.2.3-8 Clean off any sawdust, and fill hole with roof Lift shingle and slide conduit mount into place. manufacturer's approved sealant. Prepare lag bolt with sealing washer and single hole clamp (not included) as shown. Insert lag through hole in block, and position clamp over conduit. s•r mant'racutter s stecs•instructiom prior to touch,,ng a t3�� iA���CUPERTINO '. the roof. Building Department ;;=LIVED IREVIEVVED,FOR CODE COMPLIANCE quick MountTeVedBy.- 925-478-8269 • www.quickmountpv.com • info@quickmountpv.com 2700 Mitchell Dr., Bldg 2 • Walnut Creek, CA 94598 Aug-2014, Rev 4 02013 by Quick Mount PV. All rights reserved. N, SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 10300 TORRE AVENUE • CUPE:RTINO, CA 950,14-3255 (408) 777-3228 FAX (408) 777-3333- • building(@Wgerti !R. 1890 Address 21398 Place PERMIT CANNOT BE FINALED AT HAS BEEN: & AND: PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbo Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420:6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements' X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning applianc s and that. do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall com ly with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s). maybe solely battery perated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alter tions do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is re uired for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has iave been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date si - ed below. l have read and a ree to como1V with the terms and conditions of this statement O er (or Owner Agents) Name: r........ .... ... ......:................................ D :..............: - te:.. ./.. P contractor Name Signature... ... ........:. ....... ........, Lie.# ...................................... Date: ................... Smoke and CO form.doc r evised 03118114 i ee iu 1 WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION CUpETI l� 1Q300 TORREAVENUE - CUPERTINO, CA 95014-3255 (4 777-3 28 - FAX (408) 777-3333 - build ing-Acupertino.orq Owner Name PennitNo.', B-2016-1890 Address 21398 Krzi_ch_Place_ 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of [1to Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to the Building Division. / Skip the rest of the form and sign bottom of form. No Go to Question 3. 3. Is water sei wee permanently disconnected for your building? ❑ y-es Civil Code Sections 1101.1 through 1101.8 do not apply.. Skip the rest of the form and sign bottom of "No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1,.1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of LKYes My real property is built and available for use or occupancy on or before January 1 1994.. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and bottom of form.. 5. Please check ONE of the following: My properly is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a inultifani ly residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall -require no compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced. with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- cone wing plumbing fixtures throughout the building (regardless of whether property undergoes alterations or rnproveme ts).. I, as the owner, or owner's agent of this property, certify under. penalty of perjury that non -compliant plumbing fix ures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordaricei with Civil Code Sec tions 1101. through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manuf cturer•'s installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following, page. Owner or Owner Agent's Signature: Date: 6 6 Upon completing and signing this Certificate, please return it to the Building Division in order to final your buildin1hevised permit. S1 201 S.doc 08126115