Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2016-1916
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1916 8051 PRESIDIO DR CUPERTINO, CA 95014-4026 (356 11 072) CLEAN SOLAR INC SAN JOSE, CA 95112 OWNER'S NAME: TOBAGUS WENDY AND LUKITO SOPHIA SANTOSATRU DATE ISSUED: 05/09/2016 OWNER'S PHONE: 650-798-9237 PHONE NO: (408) 217-8876 LICENSED CONTRACTOR'S DECLARATION I BUILDING PERMIT INFO: License Class C10 C 6 Lic. #910849 Contractor CLEAN SOLAR INC Date 02/28/2018 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. a I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. = 4� OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the stricture is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code. Section 9.18. Signature Date BLDG —ELECT —PLUMB MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: INSTALLATION (16) ROOF MOUNTED SOLAR PANELS (5.52 KW) Sq. Ft Floor Area: I Valuation: $26354.00 APN Number: Occupancy Type: 356 11 072 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Phuong Devries Date: 05/09/2016 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Owner o thized agent-t G p 0�� Date: ���l JrI CONSTRUCTION LENDING AG NCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professio .._._._......_....._.._._........._.. ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408). 777-3333 • building] WWcupertino.org CUR'ERTINO /r PROJECT ADDRESS 'i M L•Q c1 ► i[t' APN # r I 0 `-2 / OWiVERNAME � ( 'wencty PHONE STREET ADDRESS Pt 1 „t f �/ CITY, STATE, ZIP J n �(n v� Co-q1)4FAX CONTACT NAM 4fN I ,pg /� 10� li �Ci PHO b) �^� rJ - zy E-MAI - /}� /2 / n 6p�� - 5 0 °CJ W 7J �lJ L GVJ� f 1e- C��el e& W_f STREET ADDRESS �/ �� �� ( ��- hV (ill, CITY, STATE, ZIP � �� A1 2, l! FAX "J 06 ' 65 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT ❑ CONTRACTOR - t1 CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAM fo , a A; LICE NUMBER / LICENSE TYT$ `- BUS. LIC # COMPANY NAME E-MAIL I,r�f0'& cn561CV'c F STREET ADDRESS V G . � f �j� // -�1 v I ( CITY, STATE, ZI5 n�� j 2 GJ lJ I P Zi Z "U�rll'J f / ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS C11 Y, STATE, ZIP PHONE USE OF 'e- SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial § / URBAN INTERFACE AREA ElI� Yes NO FLOOD ZONE ❑ Yes El�(NO kj SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION _ ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: IiUf KILOWATTS (COMMERCIAL ONLY):. TOTAL VALUATION:,2j �P 1 2 � U`D 7 n DESCRIPTION OF WORK r RECEIV BY:" By my signature below, I certify to each of the following: I ain the property owner or authorized agent to act on the pro wner'S ehalf. I have read this application and the information I. have provided is correct. I have read the Description of Work and verify it is accurate. I agr omply with all applicable local ordinances and state laws relati bui d�iiniz cuo/n�s�tr�uje iBI . a th rize representatives of Cupertino to enter the above •identi ied property for inspection purposes. C Signature of Applicant/Agent: y uGW 4�— Date: j SUPPLEMENTAL IVORNrATION REQUIRED OFFICE USE ONLY w ❑ OVER-THE-COUNTER F ❑ EXPRESS U :z U ❑ .STANDARD a❑ LARGE' a ❑ MAJOR PVApp 2011.doc revised 03/16/11 LABELS WILL BE ENGRAVED PLASTIC, WEATHER RESISTANT, RED WITH WHITE LETTERING, MIN 112" HIGH LETTERING 1. ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH CEC ARTICLE 690 LICENSE HOLDER'S SIGNATURE At the Main Service Panel To be installed at the junction boxes: 2. DC WIRING METHODS SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT • .. BREAKER _ _ WHERE COVERED BY THE PV MODULES AND EQUIPMENT CEC 705.12(D)(7) W, _IC SHOOK No _ ... ® • ACT(CEC 690.31(E)(1)) CLEAN To be installed at the Main Service Panel: AUTHORIZED SERWCE'R FQR ASSisTAiNCEPLACE 3. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT SOLAR INC. THE GROUND LADDER OVER OPENINGS SUCH AS 1445 KOLL CIRCLE., ® • • To be installed at the DC disconnect (inverter -integrated): WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS SUITE 109 OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE San Jose, CA.95112 SEC ® ® ® ® • • SYSTEM RA THE ACCESS POINT DOES NOT CONFLICT WITH CEC 705.12(D)(3) ®(MAX• P• ° OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, Cont. Lic # 910849 To be installed at the DC Disconnect: VPmax MAX • _®IN • OR SIGNS (CRC R331.4.2) www.cleansolar.com ® ® 4. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF • ` ® ®• • WARNIIN!G.: ELECTRIC ' W.UGH • • _ ®® ®� INVERTERS, MODULES, PV SOURCE CIRCUITS, BATTER TE- - ON BOTH THE LI N E CEC 690.53 CONNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND ® • . ® ® - ® To be installed on the Inverter: INTERCONNECTIONS SHALL BE INSTALLED ONLY BYs�,. • PPOSITION' ' ' QUALIFIED PERSONNEL (CEC 690.4(E)) � CEC 690.17 • 5. ELECTRICAL RUN IS APPROXIMATE AND WILL BEL'�`N To be installed at interactive points of connection, usually the Main • ®® ®A ® ® V DETERMINED IN THE FIELD BY OUR ELECTRICAL Service Panel CEC 690.54 & CEC 705.12(D)(4) INSTALLERS To be installed at the AC Disconnect:' ® • • . .. • t I xr a lSutLUIVV(a Uli/l 'ILCi �I EC 705.12(D)4) CEC 690.14C(2 t3r � PP�OoED PV have COMPLi�NCE 7,i„ =t cf f-.11ans ands ecifications MUST be kept at the p p Buildings with utility services and a system shall a plaque a .;,, REVIEWED FOR OQDE :,r..:. ca cues; ir1ea construction. It is unlawful to make any or directory indicating the location of the: service disconnecting 1 By: =fix o ci " c tinges or alterations on same, or to deviate means and the PV system disconnecting means Reviewed thl :rrProrn, without Approval from the Building Official. �. h,-, r•}nm i hio In nrirl vnm(-ifir-,.mflnn0 L.,a� held to permit or to be an approval of the violation LABELS SITE PLAN NOTES N p Q! N ' W o r of any provisions any-y, C Ordinance or State Law. o c duo v [— W O O LU tity/�s -�5i INSTALLATION OF G-001 TITLE SHEET; SCOPE OF WORK; SHEET INDEX T LU NLFCiV hio (16) SUNPOWER SPR-X21-345-WHT MODULES SITE PLAN NOTES o °° a (16) SOLAREDGE P400 DC -DC OPTIMIZERS & ~ ; (1) SOLAREDGE SE-5000A-US-U INVERTER C-001 PROPERTY PLAN STC RATING. 5.52 KW - �I� k TTf CEC RATING: 5.07 KW Y FS101 ROOF PLAN p�'y� �Q �yqf�-�'I wy��]}�pQy'', ppy'��q' ° r OCCUPANCY TYPE: R-3 � S-201 ROOF FRAMING PL AN; ELEVATION S� ' U51. Pres1d>I0 Dr r .` s. _� � CONSTRUCTION TYPE: V-B C3 ATTACHMENT DETAILS I`IAY C� c� l Presidio_( r._ r__._ -n__ Preslclio Dr_ . ThinkTank`Leaming , "LLJ ®j(upertitio)' - y AHJ. CITY OF CUP RTINO E co,C/� .� Z z E-601 -w-j I n n I e � APN: 356-1 1-072 Z ELECTRICAL LINE DIAGRAM o a° �� i Lt Q, - PROJECT VALUATION: $26,354.00 CL E-602 ELECTRICAL CALCULATIONS i _ y - a_ Z-001+ SPECIFICATIONS DRAWN BY: JPH �f C3'eC ® GOP DATE: 5 5 1 6 REV: 5 5 16 pp��Tp 11 1 J SHEET NUMBER: VICINITY MAP SCOPE OF WORK SHEET INDEX 0-001 100'-0" PRESIDIO DR. 70'-0" Wo ~ �6 PROPERTY LINE c �F�1!r,., 2016 CUU� BACK OF o�p������ 561-211 RESIDENCE i EXISTING RESIDENCE } Q 19'-5" Lij ry 0 50'-2" 30'-7" FRONT OF RESIDENCE 31'-4" Im SCALE:1/16" = V-0" PROPERTY PLAN (16) (N) SOLAR MODULES FLUSH -MOUNTED; PAIRED WITH (16) (N) DC -DC OPTIMIZERS TO BE MOUNTED UNDER MODULES PITCH: 18' AZIMUTH: 180' TOTAL AREA OF ARRAY: 281 FT2 11 S ACD AC DISCONNECT MP SERVICE POINT & UTILITY METERING JB JUNCTION BOX O INVERTER WITH INTEGRATED DC DISCONNECT - - - - CONDUIT RUN EQUIPMENT LEGEND (E) POOL SOLAR THERMAL (TYP) EXISTING RESIDENCE i AC C r--------------- i 36" ' JB 4" O O 0 0 2ND STORY 0 0 51" O ' 1ST STORY (E) #4 GROUND ROD + (E) #4 WATER PIPE BOND I LICENSE HOLDER'S I SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 (E) MAIN SERVICE PANEL I I Cont. Lic # 910849 www, cleansolar.com (N) AC DISCONNECT . � (N) INVERTER + DC DISCONNECT CLEAN'S0LAit CONDUIT TO BE RUN MIN. 1 " ABOVE ROOF SURFACE AND UNDER EAVES (E) CHIMINEY o 2ND STORY COMPOSITION SHINGLE ROOF N '3 s mcp 0 0�go LJJ 0 ='w Z v T COD Q 0 Lu d �fl cc c� CCUPERTINO " s 8llildin g [Department REVIEWED FOR CODE COMPLIA CE Reviewed By: U w 0 ry DRAWN BY: JPH DATE: 5/5/16 REV: 5/5/16 SCALE:1/8" =1'-0" SHEET NUMBER: FS101 SITE PLAN 1. MODULES ARE BONDED TO RAIL USING IRONRIDGE INTEGRATED GROUNDING SYSTEM (SEE ATTACHED SPEC SHEET) 2. WHEN UTILIZING THE 120% RULE, BACKFED PV BREAKERS WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET G-001 3. PV DC SYSTEM IS UNGROUNDED 4. FOR ALL SYSTEMS OVER 250V, CONCENTRIC AND ECCENTRIC KNOCKOUTS SHALL BE PROPERLY BONDED 5. THE REQUIRED DC GROUNDING ELECTRODE CONDUCTOR SHALL NOT BE TERMINATED AT THE AC SERVICE TERMINAL BAR. THE CONDUCTOR SHALL TERMINATE AT A GROUNDING ELECTRODE 6. TOTAL VOLTAGE DROP: 0.8% (8) SUNPOWER SPR-X21-345-WHT Modules paired with (8) SOLAREDGE P400 DC -DC OPTIMIZERS wired in series string L (8) SUNPOWER SPR-X21-345-WHT Modules paired with (8) SOLAREDGE P400 DC -DC OPTIMIZERS wired in series string [A] Free Air (4) #10 AWG PV wire (1) #6 AWG Bare Copper EGC JBox (1) SOLAREDGE SE5000A-US-U Inverter 30A 240V Nema 3R with integrated DC disconnect Non -Fusible Lockable ---_—— —--——— — ————- Visible -Blade I SOLAR A/C I DISCONNECT AC I SQUARE D DU221 RB I DC L J [B] 1 /2" EMT conduit (4) #10 AWG THWN-2 Wire (1) #8 AWG THWN-2 EGC [C] 1/2" EMT conduit (3) #10 AWG THWN-2 Wire (1) #8 AWG THWN-2 EGC Utility Service 120/240V (N) PV OCPD 2P 30A (E) #4 (E) #4 (E) Main Meter (E) SQUARE D HOMELINE 200A Main Service Panel (E) 200A Main Breaker G DO Par-tMent ? E E3' OND --. v lv J 2016 =rtVVED FOR CODC_ COMPLI Reviewed By: �631'_ ELECTRICAL LINE DIAGRAM I LICENSE HOLDER'S I SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleans6lar.com LEANS;OLAF 0 CF Z LCJ " T r W c ch Ln _ O N N O Cei O G v W W �z� o CM ado a Q o a � CD°° � IF— U w 0 I'M DRAWN BY: JPH DATE: 5/5/1E REV: 5/5/1E SHEET NUMBER: E-601 More than 21 % Efficiency ideal for roofs where -space is at a premium or where future expansion might,be needed. Maximum Performance Designed to ,deliver the most energy in demanding real world.' Conditions, in partial shade and hot rooftop tern peratures. 112,4 Premium Aesthetics SunPower® Signature''' Black Mertes panels blend harmoniously" rito'your roof. The most - elegant choice for your,h'ome. Maxeoha Solar Cells: Fundamentally better. Engineered for performance„ designee for-durab'ility: Engineered for' Peace `of Mind Designed to deliver consistent, trouble -free energy over a very long'.lifetime. 3.4 Designed for Durability The SunPower Maxeon Solar'cell is the.ohly cell built on a"solid copper foundation. Virtually impervious to the corrosion and -cracking that .degrade Conventional, Panels,.3 Same excellent durability. as E-Series panels, #1 Rank in Fraunhofer durability test9 100% power maintained in Atlas 25+' comprehensive Durabilitytest.10 Unmatched Performance, Reliability & Aesthetics Power Warranty ® 1 DO?k X 9s% 90% SERIES 95°b 50?v 1 754 0 5 10 15 20 25 Years - Convrnt,ona�Can^I -lin+ar warranty More guaranteed power: 95% for first 5 years, -0.496/yr. to year 25.7 SIGNATURET" SLACK SPR-X21-345 SPR-x21.335-BLK Highest Efficiency, Generate more energy per square foot X-Series residential panels convert more sunlight to electricity producing 38% more power per panel,' and 70% more energy per square foot over 25 years.',2a Highest Energy Production Produce more energy per rated watt High year one performance delivers 8-10% more energy per rated watt,2This advantage increases over time, producing 21 % more energy over the first 25 years to meet your needs.3 1204E ._.._. ............_. ...._ ....__: 2 % More Energy 110% "" "---' "--- Per Rated Watt 90 % 80 % 70% a 60% 5096 0 5 10 15 20 25 Years Maintains High - Power at High Temps No Light -Induced Degradation 6% i Avera a Watts 49d '_'_'_'/ _ Better Low -Light and Spectral Response 2% - -- i High•Performanct - Antl-Reflective Glass 0% 36% more, year 25 SPR-X21-335-BLK SPR-X21-345 Nominal Power (Pnom)11 335 W 345 W Pourer Tolerance +5/-09b +5/-0% Avg. Panel Efficient 12 21.0% 21.5% Rated Voltage (Vm ) 57.3 V 57.3 V Rated Current (Im p) 5.85 A 6.02 A Open -Circuit Voltage (Voc) 67.9 V 68.2 V Short -Circuit Current (Isc) 6.23 A 6.39 A Max. System Voltage 600 V UL & 1000 V IEC Maximum Series Fuse 15 A Power Temp Coef. -0.30% / OC Voltage Temp Coef. -167.4 mV / oC Current Temp Coef. 3.5 mA / °C REFERENCES: 1 All comparisons are SPR-)21-345 vs. a representative conventional panel: 2501N, approx. 1.6 m2, 15.3% efficiency. 2 Typically 8-10% more energy per watt, BEW/DNV Engineering "SunPower Yield Report."tan 2013. 3 SunPower 0.25°/u/yr degradation vs. 1.0%/yr cony. panel. Campeau, Z. et al. "SunPower Module Degradation Rate; SunPower wilite paper, Feb 2013: Jordan, Dirk 'SunPower Test Report," NREL, Q1-2015. 4 "SunPower Module 40-Year Useful Ufe" SunPower white paper, May 2015. Useful life is 99 out of 100 panels operating at more than 70% of rated power. 5 Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb 2014. 6 1% more energy than E-Serles panels, 8% more energy than the average of the top 10 panel companies tested in 2012 (151 panels, 102 companies), Photon international, Feb 2013. 7 Compared with the top 15 manufacturers. SunPower Warranty Review, May 2015. 8 Some restrictions and exclusions may, apply. See warranty for details. S I 5 f 8 I fa d' I- d" Combined Power and Product defect 25 year coverage that includes panel replacement costs, 8 Standard tests13 UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730 Quality Certs ISO 9001:2008, ISO 14001:2004 EHS Compliance ROHS, OHSAS 18001:2007, lead free, REACH SVHC-15S, PV Cycle Sustainabillry Cradle to Cradle (eligible for LEED points)t4 Ammonia test IEC 62716 Desert test 10.1109/PVSC.2013.6744437 Salt Spray test IEC 61701 (maximum severity) PID test Potential -Induced Degradation free: 1000V9 Available listings UL, CEC, TUV, MCS, FSEC Temperature - 40°F to +185'F (- 40^C to +85'C) Impact resistance 1 inch (25mm) diameter hail at 52 mph (23 m/s) Appearance Class A+ Solar Cells 96 Monocrystalline Maxeon Gen III Tempered Glass High transmission tempered Anti -Reflective Junction Box IP-65, MC4 Compatible Weight 41 Ibs (18.6 kg) Max load 30 G5 Frame: Wind: 62 psf, 00 Pa, 305 kg/m2 front & back Snom 125 psf, 6000 Pa, 611 kg/m2 front G3 Frame: Wind: 50 psf, 2400 Pa, 244 kg/m2 front & back Snow:112 psf, 5400 Pa, 550 kg/m2 front Frame Class 1 black anodized (highest AAMA rating) 9 X-Senes same as . eres, o tap pane manu cturers teste In 0 3 report, 3.3 dltlonal panels in 2014. Ferrara, C., et al. "Fraunhofer PV Durability Initiative for Solar Modules: Part 2". GS FRAME PROFILE Pho[ovolfaics International, 2014. In i6Mo ff Compatible 10 Compared with the non -stress -tested control panel. X-Series same as E-Series, tested In Alas 46 mm ee 25+ Durability test report Feb 2013. 1558 mm [1.8 in] V 11 Standard Test Conditions (1000 IN/M2 irradiance, AM 1.5, 25' Q. NREL calibration Standard: [61.3. in] -o{ i+ �, 12 Based current. LACaverage 5 FF and Voltage. W-70.1116� r4 E R T V N O 3o mm 12 Based on average of measured owe uctio ( T n-2 i^t 13 Type 2 fire rating per UL1703:2013, C rULg�703'jog2. G3 FRAME PROFILE 14 See sales person for details, i /'] CiuIIGlInq Department t046mm NotInViSIMountCompavble 32 mm 11.3 In) LONG SIDE 22 mm [0.9 In] SHOAT SME R E V I E WD FOR CODE C O M P L I A fames have no mounting holes. Please read the safety and installation guide. See http!/v %".sunpoA,er.com/facts for more reference in ormation. For more detalls, see extended datastleet: v"v.sunpower.com/datasheets. _ Document # 504828 Rev E (LTR_US PHOTOVOLTAIC MODULE SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com C.LE, N$OLAR C a Z � r r ED LO C 0 Lt7 r N O O N 0 cC-5co H W O O LU Z n C L. � O 00E3 U LLJ 0 CL DRAWN BY: JPH DATE: 5/5/16 REV: 5 5 16 SHEET NUMBER: Z-00 I solar=ee -. SolarEdge Single Phase Inverters For North America SE3000A-US I SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US im A..`, . The best choice for SolarEdge enabled systems Integratedarc fault protection (Type 1) for NEC 2011690.11 compliance Superior efficiency (98916) Small; lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless . Outdoor and indoor installation Fixed voltage.inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation ® Optional — revenue grade data, .ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN -CHINA-AUSTRALIA -THE NETHERLANDS-ISRAEL WWW.solaredge.us s®lar -. =9Z QUIPERTINO 64 iing Eepartment Single Phase Invert =S'rr orth America #�c SE3000A-US / SE380OA-US / SE5000 :/ 0 IA-1S SE760OA-US / SE1000OA-US / SE11400A-US Nominal AC Power Output 3000 3800 5000 6000 7600 000 @ 208V 0 1 0[a240y ..................... 11400 VA , ....... . ......................... Max. AC Power Output 3300 4150 5400 @ 208V 5450 u�240y.. ..................... 6000 ..... 8350 10800 @ 208V . .10950-@249y. .................. 12000 VA ..I........ AC Output Voltage Min: Nom: Max.ttl 183 - 268 - 229 Vac ... I ......................... ................ ........................................................................................... . ............I AC Output Voltage Min -Nom: Max.tll ✓ ✓ ✓ ✓ J 211- 240 - 264 Vac AC Frequency Min.;Nom: Max_Itl 59.3 - 60 - 60.5 (with HI country setting 57 : 60 - 60;5) .......... Hz Max. Continuous Output Current 12.5 I 16 I ?? 240V ..1... ?5...... [...... 32 ......I...42 @ 240V...I ..... 47 5 A GFDI Threshold ........................................................ 1 ....................................... A ...... .......................... Utility Monitoring, Islanding Protection, .................... Country Configurable Thresholds Yes Yes INPUT- Maximum DC Power (STC) 4050 5100 6750 8100 10250 13500 15350 W Transformer less, Ungrounded es ........ ... Max. Input Voltage 500 ... Vdc ............................. ................................................. DC Input Voltage ............................................................................................... 325 @ 208V / 350 @ 240V............................................. ... Vdc.... ..Nom. ................................. Max. Input Currentl�i 9.5 a� 240y.I...... 1$.......I...... 23.......I..3,0,-. 5 �24oV........ 34.. AdC ............................... Max. Input Short Circuit Current . ......I......13......I..15,5- Reverse:Polarity Protection Ground -Fault Isolation Detection 600ko Sensitivity „ ... .......................... imum.Inv........... ncy........ 97:�..... 982.....� ..Max CEC Weighted Efficiency 97.5 98 .............. 998 240y.�.....98.3......I......98......... 97.5 97.5 97@208V...I.......9H............�..... 97 ;5 ,� 240y.. 97.5 % ............................. Nighttime Power Consumption I < 2.5 < 4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional) . ........... . Revenue Grade Data, AN51 C12.1 optionallai Rapid Shutdown —NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installedl'I _ STANDARD COMPLIANCE Safety UL1741 UL16996 UL1998 S. ................................................................................... t.CA .....22.2............................................ ........... Grid .Connection .Standard . ...... ......................................... ........... s IEEE1547 ......................... .... .........................................................FCC................... Emissions partly class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4" minimum / 16-6 AWG ............................................................. 3/4'" minimum / 8- AWG ...I....I....................... DC Input conduit size / # of strings / 3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-2 strings g / AWG-rang? ............ 14:6 AWG............. ........... ....................................... Dimensions with Safety Switch 30.5 x 12.5 x 10.5 / in / HxWxD ................................................................ 30.Sx12.5x7.2/775x315x184 ............................................................. 775,x 315 x 260............. MM.... ..�.......) Weight with Safety Switch ....................... 51.2 / 23:?.......... ................... 54:7 / 24:7... ......................, .... 88 4 / 40 1............ ..Ib /.kg... Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user ................ . replaceable) ..................................... ........................................................ Noise < 25 ................................................................. < 50 clBA .............................................................................................................. Min. -Max. Operating Temperature -13 to +140 / -25 to +60 (-40 to +60 version availablelsi) 'F /'C Range- Protection Rating ............................................................................... NEMA 3R ........................................................ . For other regional settings please contact SolarEdge support. 01 A higher current source may be used, the Inverter will limit its input current to the values stated. l3i Revenue grade inverter P/N: SExxxxA-USOOONNR2 (for 760OW Inverter:5E7600A-US002NNR2). 14) Rapid shutdown kit P/N: SE1000-RSO.51. 61 40 version PIN: SExxxxA-USOOONNU4 (for 760OW Inverter:5E7600A-US002NNU4). 0 o CE INVERTER SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com CLEANSOL AR: 0 a Z r � ^ T cr' i1..L� oc o ch N c Lii r O O N O ER Gd.� c6 1^^ = W O O c� oc z W CM Cl- o 0- nW Go � C e-3 I� U W O CL DRAWN BY: JPH DATE: 5 5/16 REV: 5/5 16 SHEET NUMBER: Z-002.1 solar=ee z solar=@eSolarEdge Power Optimizer Module Add -On for North America CLEAN P300 / P320 / P400 / P405 SOLAR INC. 1445 KOLL CIRCLE., SolarEdge Power Optimizer SUITE 109 North hAmerica m p e� P300 P320 P400 P405 San Jose, CA. 95112 Module Add -On For I V o l l 1 J� 1 1 1 G C G (for 60-cell modules) (for high -power (for o& %tell (for thin film 60-cell modules) modules) modules) INPUT Cont. Lic # 910849 Rated Input DC Powerttl 300 320 400 405 W P300 / P320 / P400 / P405 ■ Absolute Maximum Input Voltage 48 80 125 Vdc www.cleansolar.com (Voc at lowest temperature).......................................................................................... MPPT Operating Range ................ . 8. - 48 8.- 80.................12.5 - 105........ Vdc Maximum Short Circuit Current (Isc) 10 11 10 Adc ............................................................................................................................................ ....................................... Maximum DC Input Current 12.5 13.75 12.5 Adc ................................................................................ ... .................... .............................................................. ........... Maximum Efficiency 99.5 Weighted Efficiency 98.8 e ................. Overvoltage CategoryII,LNSR OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc ® OUTPUT DURINGSTANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc ,eew�ro a,_ STANDARD'COMPLIANCE �5EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ................................................................................................................................... legs Safet IEC62109-1 class [Is UL17 ., a a................................................................................................................................. .............. .... •....... m wBRBn F � .......Y. ... ..... Yr �o- - RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc ..... _...... Y.................. ...................... ...... .. .................................. ........... Com atible Inverters All SolarEd a Single Phase and Three Phase inverters % 128x152x27.5/ 128x152x35/ 128x152x48/ F Dimensions (W x L x H) 5x5.97x1.08 5x5.97x1.37 5x5.97x1.89 mm/in ............................................... .............................................................................................................................. ei Wght (including cables) ............... 770 / 1;7....-......................... 930 / 2.05.,...........,. 930 / 2.05..-- ......r.�.�b.... �' Inpu t. Connector .................... MC4 Compatible o .......... v Output Wlre Type /Connector Double Insulated; MC4 Compatible Lp r ........................ . P.......................................... ............. . r yZj c c c� OutputWire Length.........................................:95/3:0..-.-..-..................-...............-.......3:9.......-.-..-.............!??�."F" N o C" N OperatingTemperatureRange......................................................40-+85/-40;+185................................................�O�.�F.... o � � CP Protection Rating IP68 / NEMAfiP f— y W = - ......... ....................................................................... Relative Humldlt 0 - 100 % Lam++ a a ..................Y.........................-..-.........-------...-.....-..-.-..-.-..-................................................,.................................... o - o I'I Rated STC power of the module. Module of up to+5% power tolerance allowed- Q L>•J M y d O d V V PV SYSTEM DESIGN USING l �xi SINGLE PHASE THREE PHAS RdBV T1tEB (?fig 48 A SOLAREDGE INVERTER t` ; Minimum String Length , iUll ff EDc) Power 0 timlzers 8 10 d 1 m ffilF ...................................... t PV power optimization at tale module-leve0 MaximumStringLength 25 25 S0 ..(IRyw gptimizers)................................................................................... oafner r 4.t?..... -� ,� ..,......ai..; .1... ;j..t�...0 96J ...... Up to2S%more energy MaximurnPowerpir ring•.••......•...•-......••.•.5250 6000 1275'0 ... • ........... ....... --............. ...- o Parallel Strings of Different Lengths REVIINEp R CODE C Superior efficiency (99.5/0) Yes FC7 or Orientations _ _ — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading " ations """""""'- "'-"""""'-'-""' """""""""""""""""' """""Rw1e��.. ' """""-"� OM 1ANCE RI It u not allowed to mix P405 with P300/P400/P600/P700 in one string. B�� ' — Flexible system design for maximum space utilization Y `� — Fast installation with a single bolt 0 Next generation maintenance, with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety DRAWN BY: JPH DATE: 5 16 USA - GERMANY ITALY FRANCE - JAPAN CHINA - ISRAEL AUSTRALIA WWW.solaredge.uS REV: 5 5 16 p 71 t" 0 . •. 0 0 1 SHEET NUMBER: DC-OC OPTIMIZER SPECIFICATIONS I Z-00-2.2- '%ch pe Product Data Sheet DU221 RB Safety Switch, 30A, Non -Fusible, 2-Pole j] !8(3UARE n bySchnelder Elcc«ic List Price $177.00 USD Availability Stock Item. This item is normally stocked in our distribution facility. Technical Characteristics Number of Poles 2-Pole Terminal Type Lugs Type of Duty General Duty Maximum Voltage Rating 240VAC ......... _.. Wire Size #14 to #8 AWG(AI/Cu) Action Single Throw Ampere Rating 30A Approvals UL Listed File Number E2875 Enclosure Rating NEMA 3R Enclosure Type Rainproof and Sleet/Ice proof (Indoor/Outdoor) Factory Installed Neutral No Disconnect Type Non -Fusible Mounting Type Surface Shipping and Ordering Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R Discount Schedule DE1A GTIN 00785901490340 Package Quantity 1 Weight 4.62 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Y Country of Origin MX As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 06/30/2010 15:15:03 © 2010 Schneider Electric. All rights reserved. Schneider 1 'Electric ..'' AC DISCONNECT SPECIFICATIONS IronRidge FlashFootTM is an all -in -one solar mounting product for composition shingle roofs that eliminates the need for separate standoffs, flashings, and L-feet.° FlashFoot incorporates a number of structural and waterproofing features to securely attach IronRidge Rails to roof structures, while also protecting against water intrusion and weather damage. 0 y�A .0$0„ Load Distribution Plate A solid metal plate below the L-foot increases the FlashFoot's structural strength and prevents any deformation of the flashing during installation. Certified compliant S4P&10 with lBC and IRC. Es FlashFootTM CUPERTINO LTfj ��Srt�i1e11$ N 1A Dual Mechanical Seal At the core of the FlashFoot, a pre -installed rubber bushing forms a dual mechanical seal, with its exterior compressed against the cavity of the L-foot and its interior tightly wrapping around the shaft of the lag bolt. Water Shedding Design A wide flashing layer combined with an elevated sealing platform maximizes the FlashFcot's water shedding ability. FOOTING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com ti Y1 S t LEA N S►OL AI ' yJ T moc.� N � O LtJ r• O O CV G t�� c6 h Cn W O O V = Z r- c o a rca C= co 0- Go � ® II— U w O Of Q_ DRAWN BY: JPH DATE: 5/5/16 REV: 5 5 16 SHEET NUMBER: Z-003 u \ IRON RIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in.years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect 5M against buckling and safely and efficiently" - transfer loads into the building structure �✓' Their superior spanning capability ' requires fewer roof attachments, reducing the number of roof r penetrations and the amount f of installation time. XR Rail Family Force -Stabilizing Curve Sloped roofs generate both vertical and lateral p forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather n h r and a longer system lifetime. 9 Y Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with a range of tilt leg FlashFoot and options for flat other pitched roof ® roof mounting attachments. applications. Corrosion -Resistant Materials All XR Rails are made of marine -grade r.- aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, perfectly matched to regions without snow. It achieves 6 foot spans, while also staying light and economical. • 6'spanning capability • Moderate load capability • Clear anodized finish • Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans. • 8' spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12'spanning capability Extreme load capability • Clear anodized finish Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. 100 120 None 140 XR10 XR100 r:XR1000 160 100 : - 9 1 120 k i 10-20 140 �5 160 100 30 1 160 '•s IP ERTINO 100 • i f ,.n Building Department 40 160 !! !„u�. ... _ 1) j �t�IttD 50-70 160 i 80-90 160 �. , m + Iti�� `JIEINEf] FOR CODE COMPL Reviewed 8y: C RACKING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com CLEANSOLAK C � v L W c = r N C C" N Cr c v ao r— = W O 07 � a Q = 92— � O �Q2 I— U w O DRAWN BY: JPH DATE: 5/5/16 REV: 5 5 16 SHEET NUMBER: Z-004.1 sm_Starling Madison Lofquist, Inc. Consulting Structural an.d Forensic Engineers 5224 South 39th Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fox: (602) 438-2505 ROC#291316 www.smleng.com IronRidge December 18, 2014 1495 Zephyr Ave Pagel of 20 Hayward, CA 94544 Attn: Mr. David F. Taggart, Vice President Products Subject: IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Dear Sir: We have analyzed the IronRidge XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures California Building Code 2012 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC-ES Aluminum Design Manual, 2010 Edition The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A — attached. The rails are clamped to aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail not come into contact with the roof. The effect of seismic loads (for all design categories A-F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables IA-9A are for modules with a maximum long dimension of 67.5 inches and Tables 1B-9B are for modules with a maximum long dimension of 78.5 inches. Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers c�C j'•y�ry-C '�F iti � t i U °t4'►'l�ifii�$t;19014 IronRidge Mr. David F. Taggart Page 5 of 20 IronRidge XR10 Rail, Roof Flush Mounting System — Structura `�rarly is MAY 0 � �� io REVIEWED FOR CODE COMPLI ANCE Table 4A - MAXIMUM SPANS (in) - Roof Slope 7° to 27° - Wind Zone �9WW)e iioduW XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 75 65 55 49 43 39 35 33 31 29 Category 130 75 65 55 49 43 39 35 33 31 29 B 140 71 65 55 49 43 39 35 33 31 29 150 66 65 55 49 43 39 35 33 31 29 160 62 62 54 48 43 39 35 33 31 29 170 59 59 1 53 47 1 43 39 1 35 33 31 29 100 75 65 55 49 1 43 39 1 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 70 65 55 49 43 39 35 33 31 29 Category 130 65 64 1 54 48 43 39 35 33 31 29 C 140 60 60 53 48 43 39 35 33 31 29 150 56 56 52 47 43 39 35 33 31 29 160 53 53 51 46 42 39 35 33 31 29 170 50 50 50 45 41 38 35 33 31 29 100 75 65 1 55 49 43 39 35 33 31 29 105 73 65 55 49 43 39 35 33 31 29 110 70 65 55 49 43 39 35 33 31 29 120 64 64 54 48 43 39 35 33 31 29 Category 130 60 60 53 47 43 39 35 33 31 29 D 140 55 55 52 46 42 39 35 33 31 29 150 52 52 50 46 1 42 39 35 33 31 29 160 49 1 49 1 49 45 41 38 35 33 31 29 170 46 1 46 1 46 44 40 37 35 33 31 29 Notes — see page 20 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -5- RACKING ENGINEERING 1 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com CLI ANSOLAIL C a Z � � ' r N O W N c o � 6 � = = to ;= r- o TwLO o amcm ca a �®�`_' I-- U w O DRAWN BY: JPH DATE: 5/5/16 REV: 5/5 16 SHEET NUMBER: Z-004.2 IronRidge December 18, 2014 Mr. David F. Taggart Page 20 of 20 IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis .Notes -Tabulated values are based on the following criteria: 1. Building mean roof height = 30 ft 2. Risk Category I 3. Solar maximum module long dimension is 67.5 inches for Tables IA-9A and 78.5 inches for Tables 1 B-9B. 4. Provide 2 in. clear between roof and rail 5. End cantilever span (max) = 0.40 x maximum span from above tables 6. No rail splices in end spans 7. No.rail splices in middle 1/3 of interior spans 8. Single simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans, Our analysis assumes that the rails, including the connections and associated hardware, are installed in a workmanlike manner in accordance with the "IronRidge Roof Mount Installation Manual" by IronRidge and generally accepted standards of construction practice. Additional information is available at the IronRidge web. site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager C71973 11, EM.1. r Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -20- RACKING ENGINEERING 2 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: 949.448.4100 Facsimile: 949.448.4111 www.intertek.com In the basis of the testsundertaken, the sampie(s) of.the below product have been found.to comply with the,requirements of the,referenced,specifications at the time the tests were carried out. Name;& Address: IronRidge, Inc. 1495 Zephyr Ave. Hayward,:CA 94,544 Product Description: Ratings St Principle Characteristics: Models: Brand: Name: Relevant Standards: XR'Rails with Integrated Grounding., Fire Class Resistance Rating. - Class A forSteep Slope Flush -Mount (symmetrical) Applications when ,using, Type I and _ Type 2, Listed';Photovoltaic Module. Class ,A.for Low Slope 'Flush -Mount and Tilt-Mount(symmetrical and°asymmetrical). Applications when using Type.1, Listed. PhotoyoltaicModule: 51-61GD-005, 51-61GD-005B,,51-5000-001;.and 51-65-001 N/A UL Subject 27..03 (Section.15.2,ancI45 3).0utli'ne of Investigation for'Rack.Mounting;Systems and Clamping'De,vices-for Flat-Plate;Photovoltaic Modules and Panels, Issue Number: 2, Nov,13, 2012 Referencing UL1703 (Section 31.2), $tandard.for Safety,for Flat -Plate Photovoltaic Modules -and Panel's,, May 107 2014 lntertek Testing -Services NA;,Inc. Verification Issuing Office: `25800 Commercentre Dr. take, Forest, CA-92630 Date,of`Tests: 08/2-7/2014 to.01/07/2015. Test Report,Number(s):, 101541132LAX-002 This verification is part ofthe°full test report(s) and.should'be read imply product certification. Completed byt Amar Kaeel Title: PV Engineer Signature: \Date: 01/26/2015 conjunctionmit them .This report does not`.automaiically Cl IF_RTINO r , Reviewed'by: 'Andre 4 oretoff, Title:. Revie>irVIUi(C C FCC RO�lw CpMPLfA Signature:,iIvveu by. Date: 01/26/2015 This Verification is for the exclusive use of intertek's client and is provided pursuant to the agreement between fntertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. lntertek assumes no liability to any party, other than to the Client in accordance with the agreement; for any loss, expense or damage occasioned by the use of this Verification. only the Client is authorized to permit copying or distribution of this Verification. Any use of the lntertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by fntertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-0P-11a (24-MAR-2014) E RACKING FIRE RATING CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com i0*0 C U A►1* WLAR } G 9- Z � " T r W d c m N O O N 0 0�� = L" C= c CM a o a Q oa CD cc CD ® °° a' O W O DRAWN BY: JPH DATE: 5/5/16 REV: 5 5 16 SHEET NUMBER: Z-004.3_ :r r IR®NRIDGE Simplified Grounding For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. 2; Grounding Strap Grounding Straps are used to bond rail -to -rail connections. They are only required on the rail with the grounding lug. Integrated Grounding System I Installation overview Install Roof Attachments • Install appropriate roof flashing and/or standoff for roof type. J1. • Attach L-Feet to flashing or standoff. Prepare Rail Connections • Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array. fi' 3 Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. IM Mount & Ground Rails • Attach rails to L-Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor, In Install Modules & Clamps REVIEWED FOR • Install first module using End Clamps and Grounding Mid Crdmo! :Wed • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. �j r_I'� � - Op l e] Module Frame Compatibility A Any module frames whose parameters are not listed in the l Li provided table have not been tested for compatibility. The Grounding Clamp has proven robust in grounding 60-cell and 72-cell solar module frames with box construction and a range of anodization thicknesses. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ironridge.com/ig Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) GROUNDING 5 BONDING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com C LEA N SO.I.A)R:LLJ C-3 Co CL = IO a Z � � - T V o CM n.I—o UG onMb n, 4 M-sy CUPERTINO Owner Name Address WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 777-3228% FAX (408) 777-3333 • building@cupertino.org l�/�P,i 4SC Permit No. A--�611 Y 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. K No Go to Question 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. N No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Q No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. Please check ONE of the following: ® My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water-conservin�purnbing fixtures comply with the requirements as indicated in the table on the followins ease. I Owner or Owner Agent's Signature: '°"1r I Date: 0//--P// (;:2 1 Upon completing and signing this Certificate, please return it to the Building Division in order to final your building permit. SB407 2015.doc revised 08126115