Loading...
B-2016-2009CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: o CONTRACTOR: PERMIT NO: B-2016-2009 10137 N PORTALAVE CUPERTINO, CA 95014-2322 (316 21 042) CUSTOM EXTERIORS INC PLEASANTON,CA 94588 OWNER'S NAME: CHANG JOHN N AND HELENA TRUSTEE DATE ISSUED: 05/24/2016 OWNER'S PHONE: 408-253-7651 PHONE NO (925) 249-2280 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B. C-17 Lic. #Z853QI1 w` Contractor CUSTOM EXTERIORS INC Date 04/30/2017 X BLDG _ ELECT_ PI'UMB MECH X RESIDENTIA -,,. COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my ' k„ license is in full force and effect. JOB DESCRIPTION:k4y REPLACE 14 WINDOWS AND 2 PATI(�DOORS - LE FOR LIKE IK I hereby affirm under penalty of perjury one of the following two declarations: �* ve and will maintain a certificate of consent to self-insure for Worker's mpensation, as provided for by Section 3700 of the Labor Code, for the of the work for which this is issued. a,C Kperformance permit ve and will maintain Worker's Compensation Insurance, as provided for by tion 3700 of the Labor Code, for the performance of the work for which this mit is issued. Sq. Ft Floor Area: Valuation: $16000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances ATN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 316 21 042 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against s +d City in consequence of the an'ting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, th ppli t understands and will ply with all non-point source regul io s the Cupertino Munici Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Sgg ature Date 5/24/2016 Issued by: Abby Ayende YJVIGL.I Date: 05/24/2016 OWNER—'UOWNER­UIL ER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a;roof is followi g two reasons: installed without first obtaining an inspection, I agree to remove all new materials for 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for inspection, sale (Sec.7044, Business & Professions Code) 2. 1, as owner of the property, am exclusively contracting with licensed -Signature of Applicant: contractors to construct the project(Sec.7044, Business & Professions Code).0 Dater/245 /2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE z I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 pf the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(x) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay ea Air utility Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the C e ino nic pal Code, Chapter 9j.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Cod 'S do 4 505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall ' be deemed revoked. / G Owner or authorized agent: `bate: 5/24/2016 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is A ONSTR C ON LEND_Y correct. I agree to comply with all city and county ordinances and state laws ding ageenn cy for the performance l hereby affirm that there is construction lending relating to building construction, and hereby authorize representatives of this city of work's for which this p � mitis issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands ARCHITECT'S DECLARATION and will comply with all non-point source regulations per the Cupertino Municipal 1 understand my plans shall be used as public records. Code, Section 0.18. . Licensed Signature Date 5/24/2016 Professional CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 1Q300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (4Q8) 777-3228 • FAX (408) 777-3333 buildingCcDcupertino.orq P ❑ NEW CONSTRUCTION ❑ ❑ ADDITION ALTERATION / TI REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS 7APN 10137 N PORTAL AVE, CUPERTINO, CA 95014 316-21-042 OWNER NAME JOHN & HELENA CHANE PHONE 408-253-7651 E-MAIL tradewinds.rbt.2011 @gmail.com STREET ADDRESS CITY, STATE, ZIP FAX 10137" N PORTAL AVE CUPERTINO, CA 95014 CONTACT NAME - JOHN or HELENA CHANE PHONE 408-253-7651 E-MAIL tradewinds.rbt.2011 @gmail.com STREET ADDRESS CITY, STATE, ZIP FAX 10137'N PORTAL AVE CUPERTINO, CA 95014 El OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME Custom Exteriors, Inc. LICENSE NUMBER 785361 LICENSE TYPE B, C-17 BUS. LIC # 23679 COMPANY NAME E-MAIL FAX Custom Exteriors, Inc. jkendall@cusom-exteriors.com 925-249-2290 STREET ADDRESS 2142 Rheem Drive., Suite E CITY, STATE, ZIP Pleasanton, CA 94588 PHONE 925-249-2280 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK Like for like retrofit replacement windows and patio doors EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES 1 USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA. NET AREA BATHROOM KITCHEN OTHER REMODELAREA REMODEL AREA REMODELAREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: 12DETACH ❑ ATTACH # DWELLING UNITS: IS A SECOND UNIT []YES SECOND STORY ❑ YES 1 BEING ADDED? IBI NO ADDITION? I@ NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES ^ RECEIVED BY: „ 4 T AL VALUATION: PLANNING APPL # ®NO PLANNING APPROVAL LETTER EICHLER HOME? ®NO' By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. J have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize represents of Cupertino to enter the above nVified proper for inspec ion purposes. ` Signature of Applicant/Agent:E Date: SUPPLEMENTAL INFORMA-TI REQUIRED ANGHEPEj New SFD or Multifamily dwellings: Apply for demolition permit for ❑` avER_TFIE CC#Ul� CSR © RtIILAING PLAN vi> w " " existing building(s). Demolition permit is required prior to issuance of building permit for new building. �' "EXPRESS C .PLANMN'GiP-.L:ANREVIFW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑. sTal�nATeD. �" �gLILIc woRKs , form if any Hazardous Materials are being used as part of this project. ©' ". D".. t.ARGE '. ... •; RIAE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to &ANITARYSEWERDi rRlq Building Pen -nit = > I roR submittal of application. ET -ENVfRONMENTAL ALTH BldgApp_2011.doc revised 06/21/11 ,gECEIVED Mg 2 3 4 2016 Sliding Window 35x35 Sliding Window 71x47 M Sliding TE PLANNING DEPT CUPERTINO thcxamrom, without approval from the Building Official. The staMping of this plan and specifications SHALL NOT bo hold Lo permit or to be an approval of the violation of any provisions of any City Ordinance or State Law. BY DA, PERMIT NO. FLOOR PLAN 10137N Portal Ave, Cupertino, CA OFFICE COPY Glass 21x26 2 1 X34 2 1 X34 21x26 Double Hung Window 22x46 FRIL SMOKE I CARBON MONOXIDE ALARMS 6 OWNER CERTIFICATE OF COMPLIANCE COMMUNITY QEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE- CUPERTINO, CA 95014-U55 AIPERTINO (408) 777-3228 - F&X(40877i-333 - buil_dingco)-cumerty�o 'Q�ffl Perraft No. 13 --Z 0 7-001 (Din N -PZ' L 14 VF C kA f 547" 1) C- fit #qf Alarms Smoke: Carbon Monoxide: E"01 X 2HQL.J H Nw- This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section 8314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. kL INFORMATION single-family and multi-farnily dwellings shall be provided with Smoke Alarms and Carbon to alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds , CRC Section R314 and CBC Sections 907.2.11,5 and 420.6 require that Smoke Alarms and/or Carbon to Alarms be installed. in the following locations: i Carbori, Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage.. Carbon monoxide alarms combined with smoke alarms shall comply with -CBC Section 420.6 and shall be approved pro d by the Office of'the State Fire Marshal, Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated, In exist�ng dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling knishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section 8314 and CBC Sections 907.111.4 and 420.6.2. An electrical permit is required for alarms ;which must be connected to the building wiring. i As owner of the abov6-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the. manufacturer's instructions and in compliance with the California Building and Ca ifomia Residential Codes. The alarms have been tested and are operational, as of the date signed below. I ham read and agree focorn ply Ah the terms and conditions oaf this statement . .............. ...... . . Owner (or Owner Agents) Name: Da -TOR/J C�Hft,-)G S! z ...... C? tractor Name: Si nat ....... U Date . .. . L Smoke and CO-fbi7n.doc revimd 0?178114 AREA SMOKE ALARM CO ALARM thitside be of each separate sleeping area in the immediate vicinity -of the room(g) X eve X level of a dwelling unit including basements X X -0� i Carbori, Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage.. Carbon monoxide alarms combined with smoke alarms shall comply with -CBC Section 420.6 and shall be approved pro d by the Office of'the State Fire Marshal, Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated, In exist�ng dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling knishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section 8314 and CBC Sections 907.111.4 and 420.6.2. An electrical permit is required for alarms ;which must be connected to the building wiring. i As owner of the abov6-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the. manufacturer's instructions and in compliance with the California Building and Ca ifomia Residential Codes. The alarms have been tested and are operational, as of the date signed below. I ham read and agree focorn ply Ah the terms and conditions oaf this statement . .............. ...... . . Owner (or Owner Agents) Name: Da -TOR/J C�Hft,-)G S! z ...... C? tractor Name: Si nat ....... U Date . .. . L Smoke and CO-fbi7n.doc revimd 0?178114 WATER -CONSERVING PLUMBING FIXTURES' FILE OWNER CERTIFICATE OF COMPLIANCE �— I COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION cu�� E Ij 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a.cupertino.ora Owner Name �T.J+t�_Ct;t(hrlej _ Permit No. 5 Z'vt6-2-oo Address - _l' D i F R=1 PrL PC%(IE.r Gtr.?F tt-Zc d0 CIA 1i 5.0 Ly Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 9 No Go to Question 2. , 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 1-1 The licensed plumber's certification has been provided to the Building Division. Sop the rest of the form and sign bottom of form. 9 No Go to Question 3. 3. Is water sery ce permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not (apply. Skip the rest of the form and sign bottom of form. N No G to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 11.01.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Ll Yes Mreal property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. Please check ONE of the following: 1% My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be repl ced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant, plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). El My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbingfixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing I fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 110.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following age. Owner or Owner Agent's Signature: 'i ' Date: Iz Upon conipleting and signing this Certificate, please reliirn it to the Building Division in order to final your building permit. SB4072015.doc revised 08126115 I I Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixtured (Fixture Complying with Current Code Applicable to New Construction) Fixture Type Maximum Water Usage/Flow Rate 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 Water Usage /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, Urinals Exceed 1.0 average flush volume of two reduced flushes and one full flush Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons _ Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons 1 per minute @ 60 psi j 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1,8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to -2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072015.doc revised 08126115