Loading...
B-2016-2281CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-2281 20005 NORTHWIND SQ CUPERTINO, CA 95014-0549 (316 38 001) JIM'S AIR CONDITIONING SERVICE SUNNYVALE, CA 94086 OWNER'S NAME: BRYSON JULIETTE A DATE ISSUED: 07/08/2016 OWNER'S PHONE: 408-446-1952 PHONE NO: (408) 733-7000 LICENSED CONTRA TOR' DECLARATION - BUILDING PERMIT INFO: License Class C-20 Lic. #466610 Contractor JIM'S AIR CONDITIONING SERVICE Date 11/30/2016 X BLDG _ ELECT _PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing X MECH X RESIDENTIAL _ COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: REPLACE FURNACE - SAME LOCATION; ADD ) A/C -- BACK I hereby affirm under penalty of perjury one of the following two declarations: YARD 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the iperformance of the work for which this permit is issued. 2 ' I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this _ permit is issued. Sq. Ft Floor Area: Valuation: $9100.00 APPLICANT CERTIFICATION certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize 316 38 001 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS N T STARTED may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point WITHIN 180 DAYS OF PERMIT ISSUANCE OR source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signature Date 7/812016 Issued by: Abby A e� nde OWNER-BUILDERDECLARATION Date: 07/08/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS:, following two reasons: All roofs shall be inspected prior to any roofing material beb ig installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to rem ve all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. 1, as owner of the property,, am exclusively contracting with licensed Signature ofApplicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 7/8/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" R BETTER 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS S O RE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements unde • Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will tis issued. maintain compliance with the Cupertino Municipal Code Chapter 9.12 and the certify that in the performance of the work for which this permit is issued, I Health &Safety Code, Section 25532(a) should I store r handle hazardous hall not employ any person in any manner so as to become subject to the >iWorkcr's material. Additionally, should I use equipment or devices which emit hazardous Compensation laws of California. If, after making this certificate of air contaminants as defined by the Bay Area Air Quality will maintain compliance with the Cupertino Municipal Code, anagement District I Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, ectio 25505, 25531, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agent: 414;X�U4,311-k� APPLICANT CERTIFICATION Date: 7/8/2016 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which tN; permit is issued (Sec. 3097, Civ .) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply wit on -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9. . I understand my plans shall be used as public records. Signature Date 7/8/2016 Licensed ` .......................... GENERAL PERMIT APPLICATION I E Fm jm& COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION' 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.org CUPER.TIN0 rj-) �l1 2 1 S � PLM4RI IICT XyrPrW.&TSI(` A T IV1.=T l=rmn Tr' � T n, ----'-'" '- y/' {_�tf'11J1"LLLt11\LV UJ PROJECT ADDRESS 2Q o"ff✓r 5 116,4h w1 i1 � APN a �I(P ` -m `trj O'WNTERNAMiE jv 4.16 76ipe- PHOI�E04e_ 44 ,DO•4Y /Fs E-MAIL STREET ADDRESS CITY, STATEE.ZyIPP F4X C -U rk>%yk%O C4 CONTACT NAME Z-9 KC l tj(� �f PHOT E tt s/ E-AZAIL _ /> STREET ADDRESS 9n / �%d4)e., 5 7 CITY, STATE, ZIP Svhv�Y��e c^ FP3 O)A NER ❑ OWNTER-BUILDER ❑ OWNTER AGENT COIv'TRACTOR ❑ CONTRACTOR AGEI`T ❑ ARCHITECT ❑ ENGLNEER ❑ DE\ LOPER [IT... CONTRACT,ORY-AME n q LICENSENUMBER LICEw'NSETYPE BUS. LIC ' COMPANY NAME s d �J S g - /Y `4� `(�v1(�F�T(Q� i E-MAIL , po � C.'v A-0A-� 6 n L— HW (/ FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGLNEER N.01E LICENSE NUMBER I BUS. LIC 4 COMPANY A.AME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or DUPLEX ❑ MULTI -FAMILY PROSECT IN WILDLAND ❑ ITS PROJECT IN ❑ YES BUILDING: ❑ COMASERCLAL I URBAN INTERFACE AREA ❑ NO FLOOD ZONE ❑ NO IS THE BLDG kN ❑ YES I EICHLER HOA E? ❑ NO DESCRIPTION OF WORK 5 d � m TOTAL VALUATION: RECEIVED B} _.. By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property ovmer's behalf. I havi read this application and the infonnation I have provided is Correct. I have read the Description of Work and verif}, it is accurate. I agree to comply with all z pplicable local ordinances and state laws relating to uild' g co stru ' n. I au rize representatives of Cupertino to enter the above -identified property for inspec ion purposes. Signature of Applicantrkgent: � Date: I-A'�! SUP ' LEA'IENTAL INTFORN4ATI0N REQUIRED OFFICE U E'ONLI ,' z � k ❑ OlER71 �OU'�TER4 �' �. 0 aE7tPRESS t STAT�'D r AfEPArliscApp_7011.doc revised 06121111 RE: 20005 Northwind Square, Cupertino, CA 95014 Dear Mr. Lazaro, Juliette Bryson has contacted the Association to request permission to install a new air conditioner. The Association approves the installation of the air conditioning unit by a licensed contractor and the owner of unit 20005 Northwind Cueprtino. At this time the HOA has no cause to prevent this installation and it is approved for install. The owner and said contractor may apply for permits per the City's codes and regulations. if there are any further questions, please contact me directly at the information listed below. On behalf of the Northpoint HOA, �"--- ves, General Manager Northpoint HOA 10880 Northpoint Way Cupertino, CA 95014 Office: 408-996-3734 Fax: 408-996-0226 email: manager@northpointhoa.com 10800 Northpoint Way, Cupertino, CA 95015 manaer'alnorthpointhoa.com = ALTERATIONS - HVAC " t`Fr`.f'C1 R.Ai T-f1'Lir. 7Ravicart (1R79'ii- . .'�� ..� r�saricncnt�n-awiear_vrnue�n:ceinti� -- ._ _ - CERTIFICATE OF COMPLIANCE _ _--- CF1R-ALT-03-E Alterations - HVAC CZ 1, 3 to 7 and 16 (formerly CF -1R -ALT -HVAC) (Page 1 of 1) Site Ad s� t 6067 ®�' ' EnforcementAgerity. Date Prepared: Permit#: l f emro€ Equipment Type Equipment Efficiency New: Ducting, Flenuoi, biro ' Conditioned Thermostat Required R -value Floor Area (sq ) 0 Packaged System O vaporator Coil AFUE CDP R-6 (CZ 1,3 -7� s Served by syst in Setback it System eCondensing Unit 14 SEER 13 R-8= fCZ16) Ducts 11,619sq f flf natofready 0 Furnace neset 1f EER HSPF ® R-6 tall CZ's) Plenums" present, must Q R-5 or R7.5- Uneset3 be installed) HERS VERiFICATIDN SUMMARY Listed below are Four HVAC Alteration Options. The installer determinesthe work to be competed and matches it . to one of the options below. All forms to be registered (no hand filled forms allowed). Copy of forms to be left on site for final i nspection. 1. NVAC Changeout/Repair Required Compliance Documents to be left on site far Final: Can include new ducting All Equipment, CFI11-ALT-02-E Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS Air Handler/fumace CF3R: MECH-20-HERS installer Requirement: Duct leakage (<15% or, < 101y*`to outside, or seal all accessible leaks) Exempted from duct leakage testing if: E3 1. Duct system registered with HERS provider as previously sealed, or 13 2. There is less than 40 linear feet of duct in unconditioned space, orX3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date'of buliding, 2. New HVAC System Required Compliance Documents to be left an site for Final: All new equipment and All New Ducts" CF1R-ALT-02-E CF2R-MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS" CF3R-MECH-20-HERS, MECH-22-HERS, MECH-(23or 24) -HERS' Installer Requirement: Duct leakage:S 6%, Fan Efficacy (.SSW/CFM), Air Flow �: 350 CFM/ton (or Standards Table 150.0-C j D all ernative) 13 3. All New Ducts with Replacement Required Compliance Documents to be left on site for Final: Includes replacing or installing All New CFiR-ALT-02-E Ducte and one or more of the following: CF2R-MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS Condenser Unit, Evaporator Coil, Furnace CE3R-MECH-20-HERS, MECH=(23 or U) -HERS Installer Requirement: Duct leakage 5 6%, Air Flow a 350 CFM/ton for Standards Table 150.0-C / D alternative) 13 Exempted from duct leakage testing if existing duct systems are constructed, insulated or sealed with asbestos. ® 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final: Adding or replacing ducts in unconditioned CFI11-ALT-02 E CF2R: MECH-20-HERS space but less than All New Ducts' CF3R: MECH-20-HERS installer Required to: Duct leakage (::-:.15% or, 5.10916 to outside, or seal all accessible leaks) Exempted from duct leakage testing if existing duct systems are constructed, insulated or sealed with asbestos. ' All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, be ' een floors etc. Z A New Duct system is when the duct system is constructed of at least 75 percent new duct material, and up to 25 percent ma consist of reused. parts from the dwelling unit`s existing duct system (e.g., registers, grilles, boots, air handier, plenums, duct material. 3 11-5 (1" thick insulation) for linesets rand less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfgwill require Suction tine Diameter With insulation as the following 1.5-27=21"; 2.5 -3T -2Y4", 3.5 to 4T-2'/:", 5.T -4t" Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California - 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. , 3. That the energy features and performance specifications for the design identified on this Certificate of Compliance confo to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4.; That the energy features and performance specifications, materials, components, and manufactured devices for the build ing design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part i and Part 6 of the CCR. 5. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the nforcement agency for approval with this building permit application. Responsible Designer Name. Re leD igrlatufe= Date signed: Lic`nser Company: p ', 4- a� 1 6� AAdddrress: 1 ! c, Citylstati /mp: g� r) W# Com` Phone: g � for assistance or questions regaroing Ine tnergy :�Eanaaros, coniacG ine energy noiane aa: i -ow -r iG-azw Al 0255 The Plus 80V Variable -Speed 4 -Way Multipoise Gas Furnace offers outstanding comfort and electrical efficiency in an 80% AFUE furnace. You get all of the benefits of Perfect Heat's and Perfect Humidity-: reduced drafts, reduced sound levels, longer, more gentle cycles, and less temperature differences between rooms. Also, it improves indoor air quality, plus provides outstanding electrical efficiency all year long: Homeowners can now economically run constant fan to help eliminate temperature differences throughout the house and to get better indoor air quality. This Perfect Humidity furnace also increases comfort in the summer by wringing out extra humidity. The 315AAV/JAV furnaces are approved for use with natural or propane gas; and the 315JAV is approved for use in Low NOx Air Management Districts. Bryant Evolution System When this Plus 80V gas furnace is matched with the Evolution Control and an air conditioner or heat pump, you will experience the ultimate in Perfect Heat and Perfect Humidity through unmatched control of temperature, humidity, indoor air quality, and zoning. The Bryant Evolution System also allows for worry -free operation through on-screen, text -based service reminders and equipment malfunction alerts. For even greater comfort and convenience, match the Plus 80V furnace with a two -speed Puron air conditioner or heat pump. This e will create a fully communicating system, requ thermostat wires between system components, and tr+ can even be done from the outdoor unit without enter Optional remote access through telephone or Int available when combined with a remote connectivity 0 only 4 the home. A is also • Evolution System -match with the Evolution- Control for Evolution System benefits • Perfect Heat, Perfect Humidity - operation Including Super -dehumidify mode for maximum humidity control Two-stage heating even with single -stage thermost 1 -patented Adaptive Control Technology Reduced operating sound through low -stage opera'on and sound elimination combustion system • Variable -speed ECM blovi er motor Increased SEER ratings for /C and H/P systems a compared to the Air Conditioning Heatir g and Refrigeration Insi 'tute's standard coil -only ratings when paired with selected Bryant evaporator coils. Matches CFM to cooling sys em over a wide range of static points • SmartEvap - can lower a humidity level in the home by nearly 10 percent • Certified to leak 2 percent or less of its nominal it conditioning CFM deliverd when pressurized tc 1 -In.. Water Gauge with all present air inlets and air outlets sealed. • Four -position furnace: Upflow, Horizontal Right, Horizontal Left, Downflow Thirteen different vent optic us • Compact design only 33-13 in. (847 mm) tall • Microprocessor based "sm art" control center Fan on Plus" - Continuousan speed adjustable fro thermostat Adjustable heating air temperature rise Adapts heating stages to in et demand Up to 12 cooling airflow setons with a wide range of capability Dehumidify mode Enhanced diagnostics with LED and reflective sigh glass, non-volatile fault code memory, and self test featur On -board fuse for transformer protection • Patented blocked vent safeguard to ensure proper furnace venting • Insulated blower compartment • HYBRID HEAT® Dual Fuel System compatible • All models are chimney friendly when used with a cessory vent kit • Perfect Light- Igniter • Residential installations eligible for consumerfi ancing through the Comfort Credit Program ferred TM Puron. SER1E Bryant air conditioners with Puron ® refrigerant provide a collection of features unmatched by any other family of equipment. The 124ANS has been designed utilizing Bryant's Puron refrigerant. This environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectoryorg) for the most up—to—date ratings information. , INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency • 14 SEER/11.7 — 12.2 EER (Based on tested combinations) Sound • Levels as low as 66 dBA Design Features • Small footprint • DuraGuard- cabinet — All steel cabinet construction Mesh coil guard Reliability, Quality and Toughness • Scroll compressor • Factory—supplied filter drier • High pressure switch • Accumulator • Line lengths up to 250' (76.2 m) • Low ambient operation (down to—20°Fl-28.9°C with h accessories) ambient � >t FAN ELECTRICAL DATA MA UNIT SIZE - OPER VOLTS* RLA SERIES tit/PH (dBA) (VOLTAGE) - MAX MIN LRA 018-A (N) 56.3 024-A (N) 62.9 030-A (N) 208/230/1 253 197 73.0 036-A (N) 77,0 048-A (N) 124.0 060-A (N) 152.5 036-A (P) 71.0 048-A (P) 208/230/3 253 197 83.1 060-A (P) 110.0 036--A (E) 38.0 048-A (E) 460/3 506 414 41.0 060-A (E) 52.0 LEGEND: 23.7 FLA - Full Load Amps 31.,1 HACK - Heating, Air Conditioning, Refrigeration 50 LRA - Locked Rotor Amps 1,20 NEC -. National .Electrical Code 61.5 RLA - Rated Load Amps (compressor) 13.7 * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time -Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 15.9 COMPR FAN MCA MA K FUSE** or RLA FLA (dBA) C BRK AMPS 9.0 0.50 11.8 250 20 10.9 0.50 14.1 57.0 25 14.1 0.70 18.3 58.5 30 14.1 1.20 18.8 59.5 30 18,5 1.20 24.3 59.5 40 23.7 1.45 31.,1 59.5 50 9.0 1,20 12.5 61.5 20 13.7 1.20 18.3 30 15.9 1.45 21.4 35 5.6 0.60 7.6 15 6.2 0.60 8.4 15 7.1 0.80 9.7 15 A -WEIGHTED SOUND POWER (dBA) NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). A -WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND Standard 1000 Unit Size Typical Octave Band Spectrum (dBA, without tone adjustment) Unit Size Rating (dBA) 125 18 68 (dBA) 125 250 500 1000 2000 4000 18 69 50.5 57.0 59.5 64.5 60.5 53.5 24 66 50.5 58.5 60.5 59.5 56.5 51.0 30 - 68 55.5 ® 59.5 61.5 63.5 60.0 58.0 36 71 59.5 59.5 62.0 65.5 63.5 62.0 48 70 57.5 59.5 64.0 66.0 63.0 60.5 60 73 60.0 61.5 64.5 67.0 66.0 65.5 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). A -WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND Typical Octave Band Spectrum (dBA, without tone adjustment) 250 Standard 1000 Unit Size Rating 58.0 58.5 (dBA) 125 18 68 52.5 24 65 54.5 30 68 55.0 36 71 59.5 48 70 57.5 60 73 61.0' Typical Octave Band Spectrum (dBA, without tone adjustment) 250 500 1000 2000 4000 58.0 58.5 64.5 59.5 52.5 57.5 59.5 59.0 56.0 50.5 60.0 61.5 62.5 60.0 58.0 59.5 62.5 65.0 63.0 61.5 59.5 63.0 65.0 62.5 60.0 62.0 64.0 67.0 65.5 65.5 ;NOTES: Tested:in accordance with AHRI Standard 270-013 (not listed in AHRI). Accessory sound shield will not accommodate unit sizes 18 and 24. CHARGING SUBCOOLING (TXT' -TYPE EXPANSION DEVICE) UNIT SIZE -SERIES REQUIRED SUBCOOLING °F (C) is 12(6.7) 24 12(6.7) 30 12(6.7) 36 8(4.4) 48. 12(6.7) 60 10(5.6) 7 8000 43.0 41.5 49.5 55.0 54.5 58.0 8000 42.5 40.5 49.5 55.0 54.0 57.5