12060061-FCITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 21869 GARDENVIEW LN CONTRACTOR: ERMIT NO: 12060061
OWNER'S NAME: RAJAGOPALAN KARPAKAM AND BALASUBRAM �� ��_ DATE ISSUED: 09/17/2012
OWNER'S PHONE: 6504347292 , PHONE NO:
7 LICENSED CONTRACTOR'S DECLARATION
License Class Lic. # q & }` G
Contractor f Date ��'
hereby affirm that I am licensed under the provisions of C apter, 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
granting of thi it. Additionally, the a ' ant understands and will comply
with all non- oin source regulations p he upertino Municipal Code, Section
9.18.
Signaturevry Date
❑ OWNER -BUILDER DECLARATION
I hereby affirm that 1 am exempt from the Contractor's License Law for one of
the following two reasons:
I, as owner of the property, or my employees with wages as their sole compensation,
wil I do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project (Sec.7044, Business & Professions Code).
I hereby affirm under penalty of perjury one of the following three
declarations:
1 have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
become subject to the Worker's Compensation provisions of the Labor Code, I must
forthwith comply with such provisions or this permit shall be deemed revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
9.18.
BUILDING PERMIT INFO: BLDG f— ELECT r PLUMB r
MECH r RESIDENTIAL r COMMERCIAL r—
JOB DESCRIPTION: CONSTRUCTION OF A 3,872 SQFT TWO STORY
RESIDENCE
WITH 627 SQFT GARAGE AND A 52 SQFT COVERED PORCH
Sq. Ft Floor Area: I Valuation: $700000
APN Number: 32619087.00 R Occupancy Type:
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 D YS FROM T�jCALLED INSPECTION.
Issued by4" (( �LZ Date:
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature of Applicant: Date:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
HAZARDOUS MATERIALS DISCLOSURE
1 have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain
compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health &
Safety Code, Section 25532(a) should I store or handle hazardous material.
Additionally, should I use equipment or devices which emit hazardous air
contaminants as defined by the Bay Area Air Quality Management District I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Sections 25505, 25533, and 25534.
Ownef 9fr authorized agegoV/�
Date
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of %ork's
for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Signature Date
Licensed Professional
-ItNEW CONSTRUCTION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE . CUPERTINO, CA 95014-3255
(408) 777-3228 ^ FAX (408) 777-3333 . buildingP-cupertino.org
❑ ADDITION ❑ ALTERATION / TT ❑ REVISION / DEFERRED ORIGINAL PERMIT #
PR IECT 4DDRESS 2,#7 6 ek1/e/ , L�
f/
APN
OWNER NAME 5?2lAf/ $i�i4
/C I�I"%�l'fIW�L ��717w%Y
0 10/tJ 7/� 77
E-RAIL
ER:EFr ADDRESS �x
CITY, STATE, ZIP -
FAX
CONTACT NAME
�ir�?T,
PHONE
E-
�.
STREET ADDRESS 4/� CITY, STATE, ZIP / �� p�O` y
FAX
❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT > ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑TENANT
CONTRACTOR NAME
LICENSE NUMBER
LICENSE TYPE
BUS. LIC #
COMPANY NAME
E-MAIL
FAX .
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ARCHITECT/ENGINEER NAME 24454�P / �
� � S6 LICENSE NUMBER
� Z
BUS. LIC #
COMPANY NAME
E MSILSG�pf%
FAX
STREET ADDRESS S�tv�I�
CITY, STATE, ZIP
PHONE
t7� O
DESCRIPTION OF WORK l a�7 /[�J <d /�� ��
EXISTIN,G USE
PROPOSED USE CONSTR
TYPE
# STORIES
USE
TYPE
OCC.
SQ.Ff.
VALUATION (S)
EXISAREA %®f
AREA
NEW 5 DEMO ®� TOTAL
AREA AREA NETAREA.
_
BATHROOM
REMODEL AREA
KITCHEN
REMODEL AREA
OTHER
REMODEL AREA
��-
V13
V
`�
/
PORCH AREA
DECK A697 REA
TOTAL DECK/PORCH AREA
GARAGE AREA: DETACH
,ATTACH
/
# DWELLING UNITS:
IS A SECOND UNIT ❑ YES
BEING ADDED? �r0
SECOND STORY YES
ADDITION? O
PRE -APPLICATION YES IF YES, PROVIDE COPY OF
IS THE BLDG AN
YES
RECEIVED BY:
TOTAL VALUATION:
P G APPI. # NO PLANNING APPROVAL LETTER
EICHLER HOME?
0
1A,�
By my signature below, I certify to each of the following: I am the prope er or authorized agent to act on the prrperty owner's behalf. I hav read this
application and the information I have provided is correct. I have rea t escription of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I au representatives of Cupertino to enter the above -identified property for inspection purposes.
Signature of Applicant/Agent: Date: 66 i 7—
SUPPLEMENTAL Tl UTRED
PLAN CHECK TYPE
ROUTING SLIP
❑ OVER-THE-COUNTER
BUMDING PLAN REVIEW
_ New SFD or Multifamily dwellings: Apply for demolition permit for
existing building(s). Demolition permit is required prior to issuance of building
permit for new building.
❑ EXPRESS
PLANNING PLAN REVIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
X STANDARD
PUBLIC WORKS
_
form if any Hazardous Materials are being used as part of this project.
❑
LARGE
FIRE DEPT
_ Copy of Planning Approval Letter or Meeting with Planning prior to
❑ MAJOR
SANITARY SEWER DISTRICT
submittal of Building Permit application.
❑ ENVIRONMENTAL HEALTH
BtdgApp_201 Ldoc revised 06121111
C17Y OF cCUP EIlBTENG
FEE IESTEMATD R — BUR LDRN G DRVISRON
ADDRESS: 21 69 Gardenviewr i_n
DATE:
REVIEWED BY: Sean
APN:
%06611112012
]BP#: go69OO(L' Z
*VALUATION- 1$700,000
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE: 1Vew Construction
PRIMARY SFD or Duplex
USE:
2nd Unit?Yes 0 No
PENTAMATION 1 R3SFDW
PERMIT TYPE: �
WORK
Construction of a 3872 sq ft two story residence with 627 sq ft garage and a 52 sq ft covered porch.
SCOPE
OCCUPANCY TYPE:
TYPE OF
CONSTR.
F1LR AREA
s.f.
PC FEES
PC FEE ID
BP (FEES
BP FEE ID
R-3 (Custom)
II-B,III-B,IV,V-B
4,551
$3,026.30
IR3PLNCK
$3,514.30
IR3INSP
TOTALS:
4,551
$3,026.30
$3,514.30
:llech. Plan ("heck
Plumb. flan Check
_J
Elec. Plan Check
:llech. Permit Fee:
Plumh. Permit Fee:
Ehr Pennir Fee
Other ;tlech. Insp.
Other Plumb Imp.=7-
Otter F.lec. In C
A,Icch. Insp. Fee:
Plmnb. Insp. Fee:
E/cc. Lisp. F«e:
NOTE: This estimate does not include fees due to other Departments (i, e. Planning, Public Works, Fire, Sanitary Sewer District, School
District, etc.). These fees are based on the preliminary information available and are only an estimate- Contact the Dept for addn'1 info.
]FEE ITEMS (Fee Resolution 11-053 E,ff. 7/1/11)
IFIEE
QTY/IFIEIE
MffSC I'TEI>'i[S
Plan Check Fee:
$3,026.30
Select a Misc Bldg/Structure
or Element of a Building
Suppl. PC Fee: Q Reg. Q OT
0.0
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$3,514.30
Suppl. Insp. Fee:Q Reg. ®OT
0,0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
Construction Tax: IBCONSTAXR
1
k new
units
$590.16
rldininisrrarive Fee:
O
r
Work Without Permit? 0 Yes E) No
$0.00
Advanced Planning Fee: PLLONGRNGR
$591.63
Select a Non -Residential E)
Building or Structure O
a
7'ruvel Docuinentatior,, F'cses:
Stronp, Motion Fee: IBSEISMICRg$7,82
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
SUBTOTALS:
$0.00
TOTAL FEE:
$7,820.39
Revised: 06/05/2012
Builafing 11Dep2u-tment
cuF>E NT ir.5o
CONTRACTOR / SUBCONTRACTOR LEST
City Of Cupertino
10300 Torre Avenue
Cupertino, CA 95014-3255
Telephone: 408-777-3228
Fax:408-777-3333
JOB ADDRESS: �- IW
PERMIT #
OWNER'S NAME:
PHONE #
GENERAL CONTRACTOR o 9,BUSINESS
LICENSE #
ADDRESS: U
CITY/ZIPCODE:
*Our municipal core requires all (businesses working in the city to have a City of Cupertino business license.
NO BUILDING ]FINAL OR (FINAL OCCUPANCY INSPECTIONS) WELL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPlERTINO
]BUSINESS LICENSE.
I am not using any subcontractors:
Signature ID
Please check applicable subcontractors and complete the following infformati ^"�"� y�
c%
SUBCONTRACTOR
BUSl1INlESS NAME
AUSI NESS LICENSE #
Cabinets & Millwork
`I 'a NC0j tK'�-P f 9 J
Cement Finishing
`-,� 7 Ov\CdS "%A i
Electrical
Ca Gjl oYt
Excavation
Fencing
Nt A
Flooring / Carpeting
gcro r
Linoleum / Wood
Glass / Glazing
Heating
Insulation
Landscaping
NIA
Lathing
fir' w CA , cy) �� G
Masonry
Painting / Wallpaper
Co (\,Ibl'k-rt.t e +,,0-,7 G
Paving
Plastering
`'\:a ,�� c+7C;" 'r,1,c
Plumbing
t C e, S, $P, r P1 L,^
Q 0 Y 21105
Roofing
1 dW-w Gkc-q - ` c
Septic Tank
N A
Sheet Metal`
Sheet Rock
Miuc ow c'
'
Tile
i
I`
Owner / Contractor Signature
Date
CUPERTINO
STATEMENT OF SPECIAL INSPECTIONS, 2010 CBC
COMMUNITY DEVELOPMENT DEPARTMENT ^BUILDING DIVISION1
ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL
10300 TORRE AVENUE ^ CUPERTINO, CA 95014-3255 ,1
(408) 777-3228 . FAX (408) 777-3333 o building .cuoertino.org
SITE
APN
BP#
ADDRESS
Owner... S�cvt✓A ri1�l .......
Contractor.......................................................................................................
Address..a.��6`(...... ....................................................
Address.................. .........................................................................................
City/St... C!!P.ff.&.T11Y.9.................. Z-ip.... `� � ........ Phone+1,5 30
City/St...................................... ........... Zip ................... Phone ........................
Applicant .$t;�a�.td !y..... gar.. �V82A.M!bdw ..............................
Engineer/Architect. ... ,;F,..%e.-....4.%.............................
Address.? 1.r..6q.......� W. . ! b!....Ld..............................................
Address ..%... ✓ .PC....................
City/St...................... Zip .....`.15!' )4.......Phone/j-.IS7
Cit /St.. ..:............zi hone IB.:1,0�
Y J p ... ..
PROJECT DESCRIPTION:
This "STATEMENT OF SPECIAL INSPECTIONS" is submitted in fulfillment of the requirements of CBC Sections 1704 and 1705. This
form is structured after and used by permission from the Structural Engineer Association of Northern California's (SEAONC) mode
statement of Special Inspections. Also, included with this form is the following:
❑ "LIST OF SPECIAL INSPECTION AGENCIES (page 2). A list of testing agencies and other special inspectors that will be
retained to conduct the tests and inspections for this project
❑ "SCHEDULE OF SPECIAL INSPECTION" (page 3 — 6). The Schedule of Special Inspections summarizes the Special
Inspections and tests required. Special Inspectors will refer to the approved plans and specifications for detailed special
inspection requirements. Any additional tests and inspections required by the approved plans and specifications shall also
be performed.
Special Inspections and Testing will be performed in accordance with the approved plans and specifications, this statement and CBC
Sections 1704, 1705, 1706, 1707, and 1708. Interim reports will be submitted to the Building Official and the Registered Design
Professional in Responsible Charge in accordance with CBC Section 1704.1.2.
A Final Report of Special Inspections documenting required Special Inspections, testing and correction of any discrepancies noted in
the inspections shall be submitted prior to issuance of a Certificate of Use and Occupancy (Section 1704.1.2). The Final,Report will
document:
• Required special inspections.
• Correction of discrepancies noted in inspections. (� \\
The Owner recognizes his or her obligation to ensure that the construction complies with the approv pe b ��dnts and to
implement this program of special inspections. In partial fulfillment of these obligations, the Ow i ta�a� 'directly pay for the
Special Inspections as required in CBC Section 1704.1. "�
This plan has been developed with the understanding that the Building Officia(, vill•
• Review and approve the qualifications of the Special Inspectors who will th inspections.
• Monitor special inspection activities on the job site to assure that the Special l sl3ectors are qualified and are performing their,
duties as called for in this Statement of Special Inspection.
• Review submitted inspection reports.
• Perform inspections as required by the local building code.
1 have read and acres to comoly with the terms and conditions of this statement
Prepared By:
Project 41 Engineer ❑ Architects
e_ os�b 89 /�
Registered Design Professional in Charge
Si nature ................l� d / f!>r,..................... Lic.# ............
OwnerName-
°
Owner's Authorization
2.........
.......l.
Si nature ..... .............................................. Lic.# ................ . Date:i
Inspection Agency / Inspector Name:
£i nature.................................................................... Lic.#....................................... Date:..........................
Building Official:
BuildingOfficial's Acceptance
I Signature ........................ ..................... I ...................... Lic.#....................................... Date:..........................
SpecialnspectionForm_2012.doc revised 03121112
APPROVAL OF SPECIAL INSPECTORS:
Each special inspection agency, testing facility, and special inspector shall be recognized by the Building Official prior to performing any
duties. Special Inspection agency's listed on this form must be pre -approved and listed on Cupertino's approved Special Inspector's list.
Special inspectors shall carry approved identification when performing the functions of a special inspector. Identification cards shall
follow the criteria set by the California Council of Testing and Inspection Agencies. No personnel changes shall be made without first
obtaining the approval of the Building Official. Any unauthorized personnel changes may result in a "Stop Work Order" and possible
permit revocation. To be pre- approved by the City of Cupertino, refer to the SPECIAL INSPECTION CRITERIA handout. Please allow
two weeks to complete the application process.
The following are the testinq and special inspection aqencies that will be retained to conduct tests and inspection on this project:
EXPERTISE
FIRMA I INSPECTOR INFORMATION °
1. Special Inspection (except for
firm ............... ....................................................... Add r.........................................................................................
geotechnical)
City..........................................................................................................
State .......................Zip ......................
Telephone......................................
Fax ............................................ Email .........................................................
2. Material Testing
Firm.....................................................................Addr.........................................................................................
City..........................................................................................................
State .......................Zip ......................
Telephone.......................................Fax............................................
Email.........................................................
3. Geotechnical Inspections
Firm.....................................................................Addr.........................................................................................
City..........................................................................................................
State .......................Zip ......................
Telephone......................................
Fax ............................................ Email .........................................................
4. Other:
Firm ................................ ..................................... Addr.........................................................................................
City..........................................................................................................
State .......................Zip ......................
Telephone......................................
Fax ............................................ Email.........................................................
*All agencies specified on this form must be pre -approved and listed on the City of Cupertino's Approved Special Inspector's List.
SEISMIC REQUIREMENTS (Section 9705.3.6)
Description of seismic -force -resisting system and designated seismic systems subject to special inspections as per Section 1705.3:
The extent of the seismic -force -resisting system is defined in more detail in the construction documents.
WIND REQUIREMENTS Section 1705.4.9
Description of main wind -force -resisting system and designated wind resisting components subject to special inspections in accordance with Section
1705.4.2:
The extent of the main wind -force -resisting system and wind resisting components is defined in more detail in the construction documents.
SpecialnspectionForm 2012.doc revised 03121112
SCHEDULE OF SPECIAL 1INSPECTIOM
SITE APW BP#
ADDRESS
PROJECT DESCRIPTION:
Notation Used in Table:
Column headers:
C Indicates continuous inspection is required.
P Indicates periodic inspections are required. The notes and/or contract documents should clarify.
Box entries:
X Is placed in the appropriate column to denote either "C" continuous or "P" periodic inspections.
--- Denotes an activity that is either a one-time activity or one whose frequency is defined in some other
manner.
Additional detail regarding inspections and tests are provided in the project specifications or notes on the drawings.
VERIFICATION AND INSPECTION C P REFERENCED IBC IREFEREMCE
STANDARD
INSPECTION OF FABRICATORS
1. ❑ Inspect fabricator's fabrication and quality control 1704.3
procedures.
INSPECTION OF STEEL
1. Material verification of high -strength bolts, nuts and washers.
❑ Identification marking to conform to ASTM stds
AISC 360,
specified in the approved construction documents.
__
X
Section A3.3 and
applicable ASTM
material standards
❑ Inspect fabricator's fabrication and quality control
—
X
procedures.
2. Inspection of high -strength bolting:
❑ Snug -tight joints.
---
X
❑ Pretensioned and slip -critical joints using turn -of --nut
with matchmarking, twist -off bolt or direct tension
--
X
AISC 360,
indicator methods of installation.
Section M2.5
1704.3.3
❑ Pretensioned and slip -critical joints using turn -of -nut
without matchmarking or calibrated wrench methods
X
---
of installation.
3. Material verification of structural steel and cold -formed steel deck.
❑ For structural steel, identification markings to conform
X
AISC 360,
to AISC 360.
Section M2.5
❑ For other steel, identification markings to conform to
Applicable ASTM
ASTM standards specified in the approved
--
X
material standards
construction documents.
❑ Manufacturer's certified test reports.
—
X
Specia(nspectionForm 2012.doc revised 03121112
VERIFICATION AND INSPECTION
C
P
REFERENCED
STANDARD
IIRC
IREFEREMCE
4. Material verification of weld filler materials:
❑ Identification marking to conform to AWS specification
in the approved construction documents.
—
X
AISC 360,
Section A3.5 and
applicable AWS A5
documents
—
❑ Manufacturer's certificate of compliance required.
--
X
--
—
5. Inspection of welding:
a. Structural steel and cold -formed steel deck:
Complete and partial joint penetration groove welds.
X
—
AWS D1.1
1704.3.1
❑ Multipass fillet welds.
X
—
❑ Single -pass fillet welds > 5116"
X
—
❑ Plug and slot welds.
X
--
❑ Single -pass fillet welds <= 5/16"
---
X
❑ Floor and roof deck welds.
---
X
AWS D1.3
b. Reinforcing steel:
❑ Verification of weldability of reinforcing steel other than
ASTM A 706.
--
X
AWS D1.4 ACI 318:
Section 3.5.2
-
_
❑ Reinforcing steel resisting flexural and axial forces in
intermediate and special moment frames, and
boundary elements of special structural walls of
concrete and shear reinforcement.
X
---
❑ Shear reinforcement.
X
---
❑ Other reinforcing steel.
---
X
6. Inspection of steel frame joints details for compliance:
❑ Details such as bracing and stiffening.
--
X
--
1704.3.2
❑ Member locations.
--
X
❑ Application of joint details at each connection.
—
X
VERIFICATION AND INSPECTION
C
P
REFERENCED
STANDARD
IB
�REFEREHCE
INSPECTION OF WELDING
1. ❑ Welded studs when used for structural diaphragms.
--
X
--
1704.3
2. ❑ Welding of cold -formed steel framing members.
---
X
3. ❑ Welding of stairs and railing systems.
—
X
SpecialnspectionForm 20/2.doc revised 03121112
VERIFICATION AND INSPECTION
C
P
REFERENCED
IBC
STANDARD
REFERENCE
INSPECTION OF CONCRETE
1. ❑ Inspection of reinforcing steel, including prestressing
X
ACI 318: 3.5, 7.1-7.7
1913.4
tendons and placement.
2. ❑ Inspection of reinforcing steel welding in accordance
AWS D1.4 ACI 318:
with Table 1704.3 Item 5b.
_ _
__
3.5.2
3. ❑ Inspection of bolts to be installed in concrete prior to
and during placement of concrete where allowable
X
ACI 318: 8.1.3,
1911.5, 1912.1
loads have been increased or where strength design
21.2.8
is used.
4. ❑ Inspection of anchors installed in hardened concrete.
---
X
ACI 318:
1912.1
5. ❑ Verifying use of required design mix.
1904.2.2,1913.2,
—
X
ACI 318:
1913.3
6. ❑ At time fresh concrete is sampled to fabricate
ASTM C 172
specimens for strength tests, perform slump and air
X
__
ASTM C 31
1913.10
content tests and determine the temperature of the
concrete.
ACI 318: 5.6, 5.8
7. ❑ Inspection of concrete and shotcrete placement for
X
__
ACI 318: 5.9, 5.10
1913.6, 1913.7,
proper application techniques.
1913.8
8. ❑ Inspection for maintenance of specified curing
X
ACI 318: 5.11-5.13
1913.9
temperature and techniques.
9. Inspection of prestressed concrete:
❑ Application of prestressing forces.
X
--
ACI 318: 18.20
❑ Grouting of bonded prestressing tendons in the
X
--
ACI 318: 18.18.4
seismic force -resisting system.
10. ❑ Erection of precast concrete members.
--
X
ACI 318: Ch. 16
—
11. ❑ Verification of in -situ concrete strength, prior to
stressing of tendons in posttensioned concrete and
X
ACI 318: 6.2
--
prior to removal of shores and forms from beams and
structural slabs.
12. ❑ Inspect formwork for shape, location, and dimensions
X
ACI 318: 6.6.1
of the concrete member being formed.
13. ❑ Bolts Installed in Existing Masonry or Concrete
❑ Direct tension testing of existing anchors.
--
X
See ICC ES Reports form special
inspection requirements for proprietary
❑ Direct tension testing of new bolts.
---
X
❑ Torque testing of new bolts.
___
X
products
❑ Prequalification test for bolts and other types of
_
X
anchors.
14. ❑ Other:
SpecialnspectionForm_2012.doc revised 03121112
REFERENCE FOR CRITIERA
VERIFICATION AND INSPECTION
C
P
IBC
TMS 402/ACI
THS 402/ACI
S(ECI'ION
530/ ,SCE 5
530/ASCfE 6
INSPECTION OF LEVEL 1 MASONRY
Y
1. ❑ Compliance with required inspection provisions of
the construction documents and the approved
---
x
--
---
Art. 1.5
submittals shall be verified.
2. ❑ Verification of f,,and fAAc prior to construction
X
-_
---
Art1.413
except where specifically exempted by this code.
3. ❑ Verification of slump flow and VSI as delivered to
X
__
__
___
Art. 1.5I3.1.b.3
the site for self consolidating grout.
4. As masonry construction begins, the following shall be verified to ensure compliance:
❑ Proportions of site -prepared mortar.
--
x
--
--
Art. 2.6A
❑ Construction of mortar joints.
---
x
--
--
Art.3.31B
❑ Location of reinforcement, connectors,
X
__
_
Art. 3.4, 3.6A
prestressing tendons, and anchorages.
❑ Prestressing technique.
---
x
--
--
Art. 3.613
❑ Grade and size of prestressing tendons and
"""
--
--
Art. 2.413, 2.4H
anchorages.
5. During construction the inspection program shall verify:
❑ Size and location of structural elements.
---
x
--
---
Art. 3.3F
❑ Type, size, and location of anchors, including
Sec. 1.2.2(e),
other details of anchorage of masonry to
---
X
"--
1 161
—
structural members, frames or other construction.
❑ Specified size, grade, and type of reinforcement,
anchor bolts, prestressing tendons and
--
x
--
Sec. 1.15
Art. 2.4, 3.4
anchorages.
❑ Welding of reinforcing bars.
x
---
---
---
❑ Preparation, construction and protection of
masonry during cold weather (temperature below
___
x
Sec. 2104.3,
_
Art. 1.3C, 1.31)
40 degrees F) or hot weather (temperature above
2104.4
90 degrees F).
❑ Application and measurement of prestressing
X
-
---
Art3.613
force.
6. Prior to grouting the following shall be verified to ensure compliance:
❑ Grout space is clean.
---
x
--
--
Art. 3.2D
❑ Placement of reinforcement and connectors and
__-
X
__
Sec. 1.3
Art. 3.4
prestressing tendons and anchorages.
❑ Proportions of site -prepared grout and
---
X
__
_-_
Art2 6B
prestressing grout for bonded tendons.
❑ Construction of mortar joints.
---
x
-
--
Art. 3.313
7. Grout placement:
❑ Grout placement shall be verified ensure
X
___
___
__
Art. 3.5
compliance.
❑ Observe grouting of prestressing bonded
X
__
_
Art 3.6C
tendons.
SpecialnspectionForm 2012.doc revised 03121112
REFERENCE FOR CRITERIA
VERIFICATION AND INSPECTION
C
P
IISC
YMS 4402 ACI
T42faS 4402IACI
SECTION
530/ASCE 5
530/ASCE 6
8. ❑ Preparation of any required grout specimens,
Sec.
mortar specimens, and/or prisms shall be
---
x
2105.2.2,
—
Art. 1.4
observed.
2105.3
INSPECTION OF LEVEL 2 MASONRY
1. ❑ Compliance with required inspection provisions
of the construction documents and the approved
---
x
-
--
Art. 1.5
submittals.
2. ❑ Verification of fR,and ftwc prior to construction
and for every 5,000 square feet during
--
x
--
—
Art. 1.413
construction.
3. ❑ Verification of proportions of materials in
premixed or preblended mortar and grout as
---
x
--
—
Art. 1.513
delivered to the site.
4. ❑ Verification of slump flow and VSI as delivered to
X
—
—
__
Art. 1.56.1.b.3
the site for self consolidating rout.
5. The following shall be verified to ensure compliance:
❑ Proportions of site -prepared mortar, grout, and
-_
X
—
__
Art 2 6A
prestressing grout for bonded tendons.
❑ Placement of masonry units and construction of
-'
--
---
Art. 3.313
mortar joints.
❑ Placement of reinforcement, connectors and
---
X
__
Sec. 1.15
Art. 3.4, 3.6A
prestressing tendons and anchorages.
❑ Grout space prior to grouting.
x
--
--
---
Art. 3.2D
❑ Placement of grout.
x
---
---
--
Art. 3.5
❑ Placement of prestressing grout.
x
---
---
---
Art. 3.6C
❑ Size and location of structural elements.
---
x
-
--
Art. 3.3F
❑ Type, size, and location of anchors, including
other details of anchorage of masonry to
X
__
---
Sec.1.2.2(e)
--
structural members, frames and other
construction.
❑ Specified size, grade, and type of reinforcement,
anchor bolts, prestressing tendons and
--
x
--
Sec. 1.15
Art. 2.4, 3.4
anchorages.
❑ Welding of reinforcing bars.
X
-__
—
Sec. 2.1.9.7.2,
—
3.3.3.4 (b)
❑ Preparation, construction, and protection of
masonry during cold weather (temperature below
___
x
Sec. 2104.3,
Art. 1.8C, 1.8D
40 degrees F) or hot weather (temperature above
2104.4
90 degrees F).
❑ Application and measurement of prestressing
X
___
__
—
Art. 3.65
force.
6. ❑ Preparation of any required grout specimens,
Sec.
mortar specimens, and/or prisms shall be
x
---
2105.2.2,
--
Art. 1.4
observed.
2105.3
SpecialnspectionForm 2012.doc revised 03121112
VERIFICATION AMD INSPECTION
C
P
REFERENCED
STANDARD
IIBC
(REFERENCE
INSPECTION OF WOOD
1. ❑ Inspect prefabricated wood structural elements and
assemblies in accordance with Section 1704.2.
1704.6
2. ❑ Inspect site built assemblies.
--
--
3. Inspect high -load diaphragms:
❑ Verify grade and thickness of sheathing.
--
---
❑ Verify nominal size of framing members at adjoining
panel edges.
—
—
1704.6.1
❑ Verify nail or staple diameter and length,
--
--
❑ Verify number of fastener lines,
---
---
❑ Verify spacing between fasteners in each line and at
edge margins.
4. ❑ Metal -plate -connected wood trusses spanning 60 feet
or greater: Verify temporary installation
restraintibracing and the permanent individual truss
—
X
—
1704.6.2
member bracing are installed in accordance with the
approved truss submittal package.
REQUIRED VERIFICATION AND INISPECTIORI OF SOL
1. ❑ Verify materials below footings are adequate to
X
achieve the desired bearing capacity.
2. ❑ Verify excavations are extended to proper depth and
_r
X
have reached proper material.
3. ❑ Perform classification and testing of compacted fill
X
materials.
—
Table 1704.7
4. ❑ Verify use of proper materials, densities and lift
thicknesses during placement and compaction of
X
---
compacted fill.
5. ❑ Prior to placement of compacted fill, observe subgrade
X
and verify that site has been prepared properly.
REQUIRED VEIRIFICA71OM AND INSPECTION OF DEEP DiRilflEN FOUMDATIOM (ELEMENTS
1. ❑ Verify element materials, sizes and lengths comply
X
---
with the requirements.
2. ❑ Determine capacities of test elements and conduct
X
-_-
additional load tests, as required.
3. ❑ Observe driving operations and maintain complete
X
and accurate records for each element.
4. ❑ Verify locations of piles and their plumbness, confirm
type and size of hammer, record number of blows per
__
Table 1704.8
foot of penetration, determine required penetrations to
X
--
achieve design capacity, record tip and butt elevations
and document any damage to foundation element.
5. ❑ For steel elements, perform additional inspections in
accordance with Section 1704.3.
6. ❑ For concrete elements and concrete filled elements,
perform additional inspections in accordance with
—
---
Section 1704.4.
SpeciainspectionForm_2012.doc revised 03121112
VERIFICATION AND INSPECTION
C
P
REFERENCED
STANDARD
IIBC
REFERENCE
7. ❑ For specialty piles, perform additional inspections as
determined by the registered design professional in
--
---
-
Table 1704.E
responsible charge.
REQUIRED VERIFICATION AND INSPECTION OF CAST -IN -PLACE DEEP FOUNDATION [ELEMENTS
1 ❑ Observe drilling operations and maintain complete and
X
—_
accurate records for each element.
2. ❑ Verify placement locations and plumbness, confirm
element diameters, bell diameters (if applicable),
lengths, embedment into bedrock (if applicable), and
X
--
---
Table 1704.9
adequate end -bearing strata capacity. Record
concrete or grout volumes.
3. ❑ For concrete elements, perfo: m additional inspections
in accordance with Section 1704.4.
—
HELICAL PILE FOUNDATIONS
1. ❑ Record installation equipment used, pile dimensions,
X
---
1704.10
tip elevations, final depth, final installation torque.
SPRAYED FIRE-RESISTANT MATERIALS
Physical and visual tests
1. Condition of substrates.
❑ Inspect surface for accordance with the approved fire -
resistance design and the approved manufacturer's
--
--
written instructions.
❑ Verify minimum ambient temperature before and after
_-
X
application.
--
1704.12.1
❑ Verify ventilation of area during and after application.
---
X
2. ❑ Measure average thickness per ASTM E605 and
-_
Section 1704.12.4.
3. ❑ Verify density of material for conformance with the
approved fire-resistant design and ASTM E605. (Ref.
--
--
Section 1704.12.5)
4. ❑ Test cohesive/adhesive bond strength per Section
1704.12.6.
_
5. ❑ Condition of finished application.
MISCELLANEOUS
1. Mastic and Intumescent Fire -Resistant Coating.
---
--
--
1704.13
2. Exterior Insulation and Finish Systems (EIFS). Water -
resistive barrier coating when installed over a sheathing
--
-
--
1704.14
substrate.
3. Special Cases
--
---
--
1704.15
4. Smoke Control System
--
--
--
1704.16
5. Seismic Resistance
❑ Suspended ceiling systems and their anchorage.
---
--
--
1705.3 [4.3]
SpecialnspectionForm 2012.doc revised 03121112
VERIFICATION AND INSPECTION
C
P
REFERENCEDI(�C
REFERENCESTANDARD
6. Wind Resistance
❑ Roof cladding and roof framing connections.
---
---
--
❑ Wall connections to roof and floor diaphragms and
framing.
--
--
_
❑ Roof and floor diaphragm systems, including
collectors, drag struts and boundary elements.
--
❑ Vertical wind -force -resisting systems, including braced
frames, moment frames, and shear walls.
❑ Wind -force -resisting system connections to the
foundation.
--
❑ Fabrication and installation of systems or components
required to meet the impact resistance requirements
--
--
---
of Section 1609.1.2.
SPECIAL INSPEC710H FOR WIND REQUlREMEM7S
1. Structural Wood
❑ Inspect field gluing operations of elements of the main
X
--
wind-force-resisting system.
--
1706.2
❑ Inspect nailing, bolting, anchoring, and other fastening
of components within the main windforce-resisting
--
X
system, including wood shear walls, wood
diaphragms, drag struts, braces and hold-downs.
2. Cold -Formed Steel Framing
❑ Welding of elements of the main wind -force -resisting
X
system.
❑ Inspection of screw attachments, bolting, anchoring,
and other fastening of components within the main
--
1706.3
wind -farce -resisting system including shear walls,
--
X
braces, diaphragms, collectors (drag struts) and hold-
downs.
3. Wind -resisting components
❑ Roof cladding.
--
X
—
1706.4
❑ Wall cladding.
--
X
SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
1. ❑ Special inspection for welding in accordance with the
_
1707.2
quality assurance plan requirements of AISC 341.
2. Structural Wood
❑ Inspect field gluing operations of elements of the
X
---
seismic-force-resisting system.
❑ Inspect nailing, bolting, anchoring, and other fastening
of components within the seismic -force -resisting
1707.3
system, including wood shear walls, wood
---
X
diaphragms, drag struts, braces, shear panels and
hold-downs.
3. Cold -Formed steel light -frame construction
❑ Welding of elements of the seismic -force -resisting
_
1707.4
system.
SpeciainspecaonForm 2012.doc revised 03121112
❑ Inspection of screw attachments, bolting, anchoring,
and other fastening of components within the seismic-
force -resisting system including shear walls, braces,
---
X
diaphragms, collectors (drag struts) and hold-downs.
4. Storage racks and access floors
❑ Anchorage of storage racks 8 feet or greater in height
-_
1707.5
and access floors.
5. Architectural components
❑ Inspect erection and fastening of exterior cladding
weighing more than 5 psf and higher than 30 feet
--
X
above grade or walking surface.
❑ Inspect erection and fastening of veneer weighing
more than 5 psf.and higher than 30 feet above grade
---
X
or walking surface.
—
1707.6
❑ Inspect erection and fastening of all exterior non -
bearing walls higher than 30 feet above grade or
---
X
walking surface.
❑ Inspect erection and fastening of all interior non -
bearing walls weighing more than 15 psf and higher
---
X
than 30 feet above grade or walking surface.
6. Mechanical and Electrical Components
❑ Inspect anchorage of electrical equipment for
- -
X
emergency or stand-by power systems.
❑ Inspect anchorage of non -emergency electrical
---
X
equipment.
❑ Inspect installation of piping systems and associated
mechanical units carrying flammable, combustible, or
---
X
—
1707.7
highly toxic contents.
❑ Inspect installation of HVAC ductwork that contains
X
hazardous materials.
❑ Inspect installation of vibration isolation systems
X
where required by Section 1707.7.
7. ❑ Verify that the equipment label and anchorage or
mounting conforms to the certificate of compliance
M
1707.8
when mechanical and electrical equipment must be
seismically qualified.
8. ❑ Seismic isolation system: Inspection of isolation
_
X
__
1707.9
system per ASCE 7 — Section 17.2.4.8
9. ❑ Obtain mill certificates for reinforcing steel, verify
compliance with approved construction documents,
--
--
--
1708.2
and verify steel supplied corresponds to certificate.
10. ❑ Structural Steel: Invoke the QAP Quality Assurance
___
__
__
1708.3
requirements in AISC 341.
11. ❑ Obtain certificate that equipment has been seismically
_
1708.4
qualified.
F2. ❑ Obtain system tests as required by ASCE 7 Section
1708.5
17.8.
SpecialnspectionForm 2012.doc revised 03121112
tCUPERTIIMO
COMMUNITY DEVELOPMENT DEPARTMENT o BUILDING DIVISION
ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL
10300 TORRE AVENUE o CUPERTINO, CA 95014-3255
(408) 777-3228 o FAX (408) 777-3333 o buildingO-cupertino.orq
The following list of Special Inspection Agencies and their special inspectors are approved by the CiV
of Cupertino to provide specific inspection in their respective field/ until the expiration date listed.
Agency Hairpne, Address
and/ expiration datee
SpeCi�ii Inspectors
Special irnspeCtiorn Field/
RC I
PC I
SM
SS
SW
FP
S
W
Cr.
Advanced Testing & Inspection, LLC
540 Brunken Ave Suite B
Salinas, CA 93901
Tel: (831) 422-2272,
Fax: (831)597-2004
Expires:
David Bor en
X
X
Marshall Hislop
X
X
X
X
X
Mike Marshall
X
X
X
X
Reza Mavashti
X
X
X
X
X
X
C.T Powell
X
Mo taba Tavakolian
X
++
Darwin Zacha
+d
X
Apex Testing Laboratories, Inc.
3450 Third St., Ste. 3E
San Francisco, CA 94124
Tel: (415) 550-9800
Fax: (415) 550-9880
Expires: 3/03/2012
Abdel Khelifa
X
X
X
X
X
X
X
X
BAGG Engineers
847 W. Maude Ave.
Sunnyvale, CA 94085
Tel: (408) 852-9133
Fax: (408) 852-9138
Expires: 3/03/2012
Christian Brown
X
X
X
X
Alvin McManus
X
X
X
X
Douglas Metzger
X
X
X
X
X
Steve Sommerfield
X
X
X
X
Biggs Cardosa Associates, Inc.
1871 The Alameda, Suite 200
San Jose, CA 95126
Tel: (408) 296-5515
Fax: (408) 296-8114
Expires:
David Chan
X
X
Bardan Gurung
X
John Harlander
X
Yu -Chen Lin
X
Stanley O humu
X
Hardik Patel
X
Tyson Tano
X
Claudiu To an
X
X
Deepen Upadhyay
X
Mark Wooley
X
X
X
X
Robert Yamane
X
RC = Reinforced Concrete SS = Structural Steel Welding/Bolting S = Soils
PC = Pre-stressed/Post-tensioned Concrete FP = Spray -Applied Fireproofing W = Wood
SW = Structural Mason SIN = Structural Welding CG = CalGreen Code
SpeciallnspectionList.doc revised 07106112
agency Name, Address
and expiration dateRC
Special Inspectors
Special Inspection FWdl
PC
SM
SS
S
FP
S
UV
CG
BSK Associates
1181 Quarry Lane Bldg 350
Pleasanton, CA 94566
Tel: (925) 462-4000
Fax: (925) 462-6283
Expires: 3/10/2012
Jim Auser
X
X
X
Mike Clary
X
X
X
X
X
Kevin Evans
X
X
X
Joe Ho elian
X
X
X
Dennis Ness
X
X
X
X
Darrell Richmond
X
X
X
Peter Schurman
X
Capex Engineering Inc.
571 Seville Place
Fremont, CA 94539
Tel: (510) 668-1815
Fax: (510) 490-8690
Expires: 6/25/2014
Gary Hsu
X
X
X
X
X
X
Chow, Erwin
1105 Belmont Ave.
Long Beach, CA 90804
Tel: (562) 449-7491
Expires: 4/24/2014
Erwin Chow
X
X
Construction Testing & Engineering,
Inc.
242 W. Larch Rd., Ste. F
Tracy, CA 95304
Tel: (209) 839-2890
Fax: (209) 839-2895
Expires: 3/15/2012
Cathy Bedford
X
X
Dottie Hughes
X
X
X
Eldon Carl Johnson
X
X
X
X
Kirk Kyle
X
X
X
Robert Leon
X
X
X
Dave Martinez
X
X
X
X
Lana Ribeiro
X
X
X
Steve Sommerfeld
X
X
X
RC = Reinforced Concrete SS = Structural Steel WeldinglBolting S = Soils
PC = Pre-stressed/Post-tensioned Concrete FP = Spray -Applied Fireproofing W = Wood
SM = Structural MasonLy SW = Structural Weldinq CG = CalGreen Code
SpeciallnspectionList.doc revised 07106112
Agency Name, Address
and expiration date
Special inspectors
special lnspection field
special
Pc
SM
SS
SWFP
S
tid
cG
Consolidated Engineering
Laboratories
2001 Crow Canyon Road,
Suite 100
San Ramon, CA 94583
Tel: (925) 341-7100
Fax: (925) 855-7140
Expires: 6/25/2014
Ahmed, Badaruddin
Alexander, David
X
X
X
. X
Andersen, Calvin
X
X
X
Bartlett, Dennis
X
X
Bobrovitsk , Edward
X
X
X
Bolen, Michael
X
X
X
X
Brooks, Brendan
X
X
X
X
X
X
Brown, Ronald
X
X
X
X
X
X
Buchmiller, Kenn
Coffin ham, Paul
Currier, James
X
X
Eschliman, Duaine
Eschliman, Kevin
Fuller, Mark
X
X
X
Halloran, James
X
X
X
X
X
X
Harrington, Wayne
X
X
X
Hassebrock, Scott
X
X
X
X
X
X
Healy,Michael
X
X
Heilmann, Mark
X
X
X
X
Hornyak, John
X
X
X
X
X
Hyslop, John
X
X
X
X
X
King, Phillip
X
X
X
X
X
Kmitt, Stanley
X
X
X
Liebold, Jeffrey
X
X
X
X
X
X
Lozano, Alfonso Art
Ma, Steven
X
Marlik, William
X
X
X
McCutcheon, Thurmond
X
X
X
McKenzie, Quinten
McLaughlin, Lori
X
X
X
Miner, Dwight
X
X
X
Murphy, Don
X
X
Pastora, George
X
X
X
X
X
Rodriguez, Sandra
X
X
X
Si mon, Josephine
Sisson, James
X
X
X
X
Small, Michael
X
X
Van Horn, Bradford
X
X
X
X
Walters, Michael
Zuerner, Robert
X
X
X
RC = Reinforced Concrete SS = Structural Steel WeldinglBolting S = Soils
PC = Pre-stressed/Post-tensioned Concrete FP = Spray -Applied Fireproofing W = Wood
SM = Structural Masonry SW = Structural Welding CG = CalGreen Code
SpeciallnspeclionLfsi.doe revised 07106112
Agency Name, Address
and expiration date
Special inspectors
Special Inspection Held
RC
PC
SM
SS
SW
FP
S
UV
CG
Construction Testing Services
2174 Rheem Dr., Ste. A
Pleasanton, CA 94588
Tel: (925) 462-5151
Fax: (925) 462-5183
Expires: 6/26/2014
Brian Arnold
X
X
X
X
Edward Bindert
X
X
X
X
X
Jeremy Brown
X
X
X
X
James Brumley
X
X
Jared Byers
X
X
Richard Collin
X
X
X
X
Robert Cortez
X
X
X
X
X
X
Robert Criswell
X
X
X
X
Mark Doman
X
X
X
X
X
Tom Edwards
X
X
X
X
X
X
Tim Farley
X
X
X
X
X
X
X
Gary Fechner
X
X
X
X
Mike Gaunt
X
X-
Ron Harr
X
X
X
X
X
Neal Hoellwarth
X
Richard Jones
X
X
X
X
X
Rick Mann
X
X
X
Kevin McCurdyX
X
Kevin Meyers
X
X
Kevin Moore
X
X
Craig Nagle
David Puskarich
X
X
X
X
William Radulovich
Brian Ragan
X
X
X
X
X
X
John Rink
X
X
George Rockenstein
X
X
Larry Rothey
X
X
Erin Salazar
X
X
Robert Schulze
X
Donald ShirleyX
X
X
Tom Shuster
X
X
X
X
X
X
Larry Slater
X
X
Daryl S ieker
X
X
Gary Stapleton
X
X
X
X
Matt Swope
X
X
Travis Taylor
X
X
X
Vinny Vinavong
X
X
Shawn Vucenic
X
X
John White
X
X
X
X
X
X
Isidoro Za ien
X
X
X
X
RC = Reinforced Concrete SS = Structural Steel Welding(Bolting S = Soils
PC = Pre-stressed/Post-tensioned Concrete FP = Spray -Applied Fireproofing W = Mood
SM = Structural Masonry SW = Structural Welding CG = CalGreen Code
SpeciallnspectionList.doc revised 07106112
Agent;y Name, Address
and expiration date
�(peC9S9 ierspeCtoP`S
Special] Inspection FWd
RC
PC
SM
SS
SYd .
FP
S
vu
CC
Earth Systems Pacific
446 S. Hillview Dr.
Milpitas, CA 95035
Tel: (408) 934-9302
Fax: (831) 637-0510
Exp: 6/28/2014
George Barnett
X
X
Jeff Bryan
X
X
Norman En en
X
X
X
X
X
Cal Hicks
X
X
X
X
X
X
Dennis HurleyX
X rus Me'ia
ENGEO Incorporated
2010 Crow Canyon PI., Suite 250
San Ramon, CA 94583
Tel: (925) 866-9000
Fax: (888) 279-2698
Exp: 7/06/2014
Tim Benton
Greg Hudson
X
Mike Huener ardt
X
X
X
X
X
Kevin Lecce
James "Chip" Moore
X
X
X
Randy Mues
X
Jonathan Parker
X
X
X
X
Rich Rose
X
X
X
FHP Inspections, Inc.
690 Sunol St., Bldg. H
San Jose, CA 95126
Tel: (408) 288-8460
Fax: (408) 271-0902
Expires: 3/22/2012
Tony Cotta
X
X
Chuck Pinkham
X
X
X
X
David Pinkham
X
X
X
X
P. Scott Pinkham
X
X
X
Joel Sorenson
X
X
X
X
Gary Stafford
X
X
X
X
X
Jason Waugh
X
X
X
X
X
KC Engineering Co.
865 Cotting Lane, Suite A
Vacaville, CA 95688
Tel: (707) 447-4025
Fax: (707) 447-4143
Exp: 3/18/2012
Dennis Brown
X
X
Art Crawford Jr.
X
X
X
X
X
Maurice Mathews
X
X
X
X
X
Ted Scibek
X
X
X
RC = Reinforced Concrete SS = Structural Steel Welding/Bolting S = Soils
PC = Pre-stressedlPost-tensioned Concrete FP = Spray-Applled Fireprooring W = Wood
SMI = Structural Mason SW = Structural Welding CG = CalGreen Code
SpeciallnspeclionList.doc revised 07106112
Agency Name, Address
dateRC
Special Inspectors
Speciall Inspection Fieldandexpiration
PC
SWI
SS
SUV
FP
S
W
CO.
Krazan & Associates, Inc.
6711 Sierra Court, Ste B
Dublin, CA 94568
Tel: (925) 307-1160
Fax: (925) 307-1161
Exp: 2/6/2014
James Allen
X
X
X
James Benefeito
X
X
X
X
Larry Borges
X
X
X
X
X
Ron Chandler
X
X
Van DeMent
X
X
X
Gregory Fernald
Matthew Fernald
Lewis Franklin
X
X
X
X
X
X
Ken Hafeli
X
X
X
X
Andy Morris
X
X
X
X
X
Sidney Moss
X
X
X
X
X
Matt Romero
X
Gregory Ruf
MatriScope Engineering
Laboratories, Inc.
436 14th Street, Suite 1429
Oakland, CA 94612
Tel: (510) 763-3601
Fax: (510) 763-1388
Expires: 3/19/2012
Kevin Muser
X
X
X
X
X
Steven W. Russell
X
X
X
X
Jack Sta ner
X
X
X
X
X
X
Joe Varella
X
X
X
X
Neil O. Anderson and Associates
50 Goldenland Ct., #100
Sacramento, CA 95834
Tel: (916) 928-4690
Fax: (916) 928-4697
Exp: 4/19/2012
Michael A. Cozad, ASc
X
X
X
X
X
Katie L. Demuth
X
X
X
X
David C. Gray
X
X
X
X
X
Rollin Hall
X
X
X
X
Jason Kort
X
X
X
Donald
X
George O as
X
X
Colin Stock
X
X
Roger T. Williams
X
X
X
X
PacificlnterWest Bldg Consultants, Inc.
1600 South Main St, Suite 380
Walnut Creek, CA 94596
Tel: (925) 939-5500
Fax: (925) 939-9561
Expires: 9/6/2013
Doug Coe
X
PSI, Inc.
365 Victor Street, Suite C
Salinas, CA 93907
Tel: (831) 757-3536
Fax: (831) 757-6265
Expires: 12/31/2010
Albert George
X
X
X
RC = Reinforced Concrete SS = Structural Steel WNeldingl8olting S = Soils
PC = Pre-stressed/Post-tensioned Concrete FP = Spray -Applied Fireproofing WR/ = Wood
SM = Structural Mason SNW1= Structural Weldinq CG = CalGreen Code
SpeciallnspectionGist.doc revised 07106112
Agency Name, Address
and expiration date
Special [Inspectors
Special pnspection Field
RC
PC
SM
SS
SW
I FP
I S
I ti#I
I CO
RES Engineers, Inc.
150 North Wiget Lane, Suite 204
Walnut Creek, CA 94598
Tel: (925) 932-4600
Fax: (925) 9324625
Exp: 3/19/2012
Michael A. Cozad, ASc
X
X
X
X
X
Katie L. Demuth
X
X
X
X
David C. Gray
X
X
X
X
X
Rollin Hall
X
X
X
X
Jason Kort
X
X
X
RMA Group of Northern California
6296 San Ignacio Ave., Suite A
San Jose, CA 95119
Tel: (408) 362-4920
Fax: (408) 362-4926
Expires: 04/01 /2012
Maurice Alley
X
X
Jeff Bosque
X
X
X
Greg Carr
Joe Cecconi
X
Gordon Chinn
X
X
X
X
Chris Francis
X
X
Rich Geraghty
X
X
X
John Gillespie
X
X
X
X
X
Al Gundersen
X
X
X
Tiffany Haff
Dottie Hughes
X
X
X
Jeff Sondrol
X
X
X
X
Jacob Stocke
X
Pat Swain
X
Mike Tellesen
X
X
Bill Tonkovich
X
X
X
X
Chris Walters
X
X
X
X
X
X
Adam Zeiher
X
Signet Testing Labs, Inc.
3121 Diablo Avenue
Hayward, CA 94545
Tel: (510) 887-8484
Fax: (510) 783-4295
Expires: 8/4/2012
Garrett Baccus
X
X
Robert Bigford
X
Paul Colby
X
X
Bob Haynes Sr.
X
Willis Hughes
X
X
X
Fred Mangrum
X
X
X
Jeffery McPeek
X
X
John Pagliero
X
X
Rodger Patterson
X
X
X
X
Robert Stalf
X
X
X
X
X
Doug Stark
X
X
X
X
Pat Toschi
X
X
X
X
X
RC = Reinforced Concrete SS = Structural Steel Welding/Bolting S = Soils
PC = Pre-stressed/Post-tensioned Concrete FP = Spray -Applied Fireproofing W= Wood
SM = Structural Mason SW = Structural Welding CG = CalGreen Code
SpeciallnspectionList.doc revised 07106112
Agency Name, Address
and expiration date
��BeCiaO OP9S�DeC1�®PS
Special lnspeCtion Meld
RC
PC
SM
SS
SW
FP
S
W
CG
Stevens Ferrone & Bailey
1470 Enea Circle, Suite 1551
Concord, CA 94520
Tel: (925) 688-1001
Fax: (925) 688-1005
Expires: 3/18/2012
Marty Babione
X
X
X
Scott Conner
X
X
X
X
X
X
X
Breit Fletcher
X
X
X
X
X
X
X
Richard Fletcher
X
X
X
X
Matthew Minor
X
X
X
Tom Quinn
X
X
X
X
Jay T. Wolfe
X
X
X
X
X
X
X
X
George Yamaichi
X
Testing Engineers, Inc.
2811 Teagarden Street
San Leandro, CA 94577
Tel: (510) 835-3142
Fax: (510) 834-3777
Expires: 11/02/2012
Mike Ardizonne
X
Eric Dixon
X
John Dougherty
X
X
X
X
Jim Ganly
Frank Hernandez
X
X
X
Jeff Messinger
X
X
Bruce Muzika
X
X
Rich Rose
X
X
X
Jason Souza
X
X
Tom Speger
X
X
X
X
X
X
Howard Stephenson
X
X
X
X
X
X
Mike Tellesen
X
X
Dennis Wertz
X
X
X
Brian Williams
X
Tim Woodbeck
X
X
Tony Woodbeck
X
John Yoka
X
X
X
Valley Inspection, Inc.
326 Woodrow Ave.
Vallejo, CA 94591-7302
Tel: (707) 552-7037
Fax: (707) 552-7022
Expires: 7/16/2012
Carroll Strickland
X
X
RC = Reinforced Concrete SS = Structural Steel Welding/Bolting S = Soils
PC = Pre-stressed/Post-tensioned Concrete FP = Spray -Applied Fireproofing W = Wood
SM = Structural Wason SW = Structural Welding CG = Ca/Green Code
revised 07106112
Saw dose
140 company
F eel?
110 W. Taylor Street
San Jose, CA 95110-2131
April 9, 2013
3
Karpakam Rajagopalan
21869 Gardenview Lane
Cupertino, CA 95014
Reference: 21869 Gardenview Lane, Cupertino
Dear Ms. Rajagopalan:
San Jose Water Company
Water Services Administration
1265 S. Bascom Ave., San Jose, CA 95128
Facsimile: 1 408 279-7889
Writer's Direct Dial: 1 408 279-7879
am," IE 1L V MTO--
APR 11 .-1-3
/1� 61(000& /
The purpose of this letter is to inform you of the procedures you need to follow to finalize
the installation of a new water service for this project, and to retire and abandon the existing
service at this site. Basically, you will need to hire a contractor to perform the work to our
standards and under our inspection. It is suggested, but not required, that you contact one of our
general contractors to have the work performed. They are West Valley Construction at 408-371-
5510, and Lewis & Tibbitts at 408-925-0220. In any case, your contractor must possess a valid
license for this type of work, and must obtain a permit from the City of Cupertino to do the job.
Based on the data you supplied on our water service questionnaire, our Engineering
Department has determined that a 1'/2" copper service with a check valve needs to be installed for
this residence. The piping from the check valve/meter to the house should be 2" in size. By copy
of this letter, we are informing the City of Cupertino of our determination, and I have enclosed
our standard service drawing that details an approved installation. You also need to retire and
abandon the existing service by disconnecting it at the water main in the street. The meter/check
valve (service con section) defines the point at which you receive service, and the point where the
owner's piping begins. The owner of the property is responsible for all piping and equipment past
the check valve.
Please note that in addition to the check valve in the meter box, you must also install a
rubber seated single check valve (property of the owner) on the internal plumbing of the house.
The location of the check valve must be where the fire sprinkler piping tees off from the domestic
piping. Also, the water pressure in this area is over 80 PSI (approximate range at the meter will
be 118 127 PSI). San Jose Water Company recommends that a pressure regulator be installed
on private service lines that will prevent pressure in excess of 80 PSI from entering the structure.
Please contact your plumberregarding this matter.
Karpakam Rajagopalan
April 9, 2013
Page Two
If you would like to proceed with the work, please sign, date, and return this letter with a
construction deposit as discussed below. Also include the address where the monthly billings
should be sent. Monthly billings start when the meter is installed, and a copy of our rate
schedule is enclosed for your information. You must also submit a deposit in the amount of
$829 to cover the cost of our reviews, inspection, and the purchase and installation of the new
meter and check valve. Please make your check payable to San Jose Water Company.
At the appropriate time, you will need to provide our Construction Department at least
one week notice for inspection services. Your contact is Nick Bernhardt, who can be reached at
1-408-279-7830. A San Jose Water Company inspector must witness the actual tap of the water
main. Once the service lateral and meter box have been installed and approved, we can install
the meter and check valve at your request.
If you have any questions or require further information, please contact me at 1-408-279-
7879.
WEF:dmk
Enclosures
gardenview.doc
cc;,Wflding Department, City of Cupertino
ACKNOWLEDGED AND AGREED
Responsible Party
Signature
Print Name
Date
Sincerely,
ORRIN& NEED o V
Wanda E. Folk
Water Services Representative
MONTHLY LY BILLINGS TO.
Name
Address
City
Phone Number
CUPERTINO
PURPOSE:
2010 CALGREEN RESIDENTIAL CHECKLIST
MANDATORY D EMS
COMMUNITY DEVELOPMENT DEPARTMENT ^BUILDING DIVISION
ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3228 ^ FAX (408) 777-3333 o building6d�cupertinc.orq
The 2010 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings,
dormitories, condominiums, shelters, congregate residences, employee housing, factory -built housing and
other types of swellings with sleeping accommodations and new accessory buildings associated with such
uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the
requirements of CALGreen.
Project Name:
Project Address:
s o-'04,` Poj e.�; —jcr 113 (�
'2160q Cqarden+ti o ,fin. Cz4 oer-Ilno V
Project Description: 4ai' Z Sow' hoL,ze
J� �� C E C (0,1
�
Instructions: i'
1. The Owner or the Owner's agent shall employ a,licensed• professional experienced with the 2010 California
Green Building Standards Codes to verify and assure that all required work described herein is properly
planned and implemented in the project.
2. The licensed professional, in collaboration with the owner and the design professional shall initial Column
2 of this checklist, sign and date Section 1 - Design !Verification at the end of this checklist and have the
checklist printed on the approved plans for the project.
3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3
and sign and date Section 2 e Implementation Verification at the end of this checklist and submit the
completed form to the Building Inspector.
Column 2 Column 3
MANDATORY FEATURE OR MEASURE Project Verification
Requirements
A4.1 PLANNING AND DESIGN
Planning aridtiDesigrn '^ Situ Preservation
Y t -
4.104.1 A site plan and inventory of the site is developed and used to minimize
site disturbance in order preserve desirable existing natural resources and
®I
J9
minimize future adverse effects on the proposed structure.
Planning and Design Safe Development
4.106.2 A plan is developed and implemented to manage storm water
XI
9
drainage during construction.
4.106.3 The site shall be planned and developed to keep surface water away
from buildings. Construction plans shall indicate how site grading or a drainage
system will manage all surface water flows.
Page 1 of 5 CalGreen_2010.doc revised 08127111
A4.5 ENVIRONMENTAL
-:--- -
Fireplaces
4.503.1 Install only a direct -vent sealed -combustion gas or sealed wood-
®
n
burning fireplace, or a sealed woodstove.
hl'oflutant�Control ;-
4.504.1 Duct openings and other related air distribution component openings
shall be covered during construction.
4.504.2.1 Adhesives, sealants and caulks shall be compliant with VOC and
X�
1�
Ill
other toxic compound limits.
4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits.
®
�I
4.504.2.3 Aerosol paints and other coatings shall be compliant with product
FS
weighted MIR Limits for ROC and other toxic compounds.
4.504.2.4 Documentation shall be provided to verify that compliant VOC limit
finish materials have been used.
4.504.3 Carpet and carpet systems shall be compliant with VOC limits.
4.504.4 Fifty (50) percent of floor area receiving resilient flooring shall comply
with the VOC-emission limits defined in the Collaborative for High Performance
Schools (CHPS) Low -emitting Materials List or be certified under the Resilient
Floor Covering Institute (RCFI) FloorScore program.
4.504.5 Particleboard, medium density fiberboard (NIDF), and hardwood
plywood used in interior finish systems shall comply with low formaldehyde
FF
emission standards.
Interior Moisture Control
4.505.2 Vapor retarder and capillary break is installed at slab on grade
foundations.
4.505.3 Moisture content of building materials used in wall and floor framing is
checked before enclosure.
Page 3 of 5 CalGreen_2010.doc revised 08127111
Project Name: Srr n�aj eLf// 3
Project Address: v,ew Lee Cu�or�/ 9SU��r
Project Description:
SEcnoN i - DESIGN VERIFICATION
Complete all lines of Section 1 — "Design Verification" and submit the completed checklist (Columns 1 and 2) with the
plans and building permit application to the Building Department.
The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and
certify that the items checked above are hereby incorporated into the project plans and will be implemented into the
project in accordance with the requirements set forth in the 2010 California Green Building Standards Code as
adopted by the q4kof Cupertino.
Owner's
Owner's Name (Please Print)
Design P essional's Signature
5(A5?,e h C,4 64
Design Pro�.ssionai's Name (Please Print)
--- - -
Signat of License Professional responsible for CalGreen compliance
ltik -c4eh
Name of License Professional respo� ible for CalGreen compliance (Please Print)
Email Address for License Professional responsible for CalGreen compliance
SECTION 2 — IMPLEMENTATION VERIFICATION
Date
O`d Zo / Z
Date
O-o(Zb/IZ
Date
Phone
Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section
2 to the Building Department prior to Building Department final inspection.
have inspected the work and have received sufficient documentation to verify and certify that the project identified
above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of
the 2010 California Green Building Standards Code as adopted by the City of Cupertino.
Signature of License Professional responsible for CalGreen compliance Date
Name of License Professional responsible for CalGreen compliance (Please Print) Phone
Email Address for License Professional responsible for CalGreen compliance
Page 5 of 5
CalGreen 2010.doc revised 08127111
rN
STMEMEN u OF SPECIALS IIHS C mril0o ms26
9
COMMUNITY DEVELOPMENT DEPARTMEN ILDIING DIVISION
ALBERT SALVADOR, P.E.,.C.B.O., BUILD ,
CUPERTINO 10300 TORRE AVENUE ^ CUPERTINO, CA 95014-325 , - _>�
(408) 777-3228 ^ FAX (408) 777-3333 - butilldin Iiger'U'no.or
f1 .iY �,'r
SITE I�6
ADDRESS
1 f i PG-Zn/N1�=t./ �/ Uft*-TtAlo 1
0� �� C��
BP#
CC*
Owner..$. .�!�.h.!!Pz",tam...mW.......................
Contractor...................... \.J
Address.-?-. LN1....... cl.fAA-1 1!>`mIt ✓............................................
Address...........................................................................................................
City/St........ ..eo `�M.®......... Zip.... �.�. .......Phone.�.t0..-..iyly
y�City/St....... ........ ......... ......................... Zip ...................
Phone ................... .....
Applicant..... ............................. .................
Engineer/Architect.,,O; !�,e
Address...........................................................................................................
Address-72-4jl .-- RAI-PAyoy....'�
..0.......................
City/St............................................. Zip ..... ...................... Phone .....................
City/St..��. . ....PR.;... ..............Zlp.
Phonell7...:i0.7..
PROJECT DESCRIPTION: �o�c�, 4 04(34 -z-
Sri lam` ( V�rf��
ca.A-co G-,C1
This "STATEMENT OF SPECIAL INSPECTIONS" is submitted in fulfillment of the requirements of CBC Sections 1704 ark 1705. This
form is structured after and used by permission from the Structural Engineer Association of Northern California's (SEAON bilk
statement of Special Inspections. Also, included with this form is the following: I
❑ "LIST OF SPECIAL INSPECTION AGENCIES (page 2). A list of testing agencies and other special inspectorglt� be
retained to conduct the tests and inspections for this project �•
❑ "SCHEDULE OF SPECIAL INSPECTION" (page 3 - 6). The Schedule of Special Inspections summarizes th S
Inspections and tests required. Special Inspectors will refer to the approved plans and specifications for Ii .gp coal -.
inspection requirements. Any additional tests and inspections required by the approved plans and specif a10-shaC�alsd be performed.
Special Inspections and Testing will be performed in accordance with the approved plans and specifications, this sta�& an�£BG�
Sections 1704, 1705, 1706, 1707, and 1708. Interim reports will be submitted to the Building Official and the Registen._:+%
Professional in Responsible Charge in accordance with CBC Section 1704.1.2. 5177
A Final Report of Special Inspections documenting required Special Inspections, testing and correction of any discre io�io in`/%-
the inspections shall be submitted prior to issuance of a Certificate of Use and Occupancy (Section 1704.1.2). The F�
document: � P
•
Required special inspections. Fri `
• Correction of discrepancies noted in inspections. 00{
The Owner recognizes his or her obligation to ensure that the construction complies with the approved permit docu4�1'dta%;
implement this program of special inspections. In partial fulfillment of these obligations, the Owner will retain and directly pifot°t
Special Inspections as required in CBC Section 1704.1.,E �=
This plan has been developed with the understanding that the Building Official will:
• Review and approve the qualifications of the Special Inspectors who will perform the inspections.
• Monitor special inspection activities on the job site to assure that the Special Inspectors are qualified and are perPlfrr ing hheir
duties as called for in this Statement of Special Inspection.
• Review submitted inspection reports.
• Perform inspections as required by the local building code.
I have read and a ree to comply with the terms and conditions of this statement
Prepared By:
Project J Engineer ❑ Architect
gl
Registered Design Professional in Charge
Si nature ...................
................. Lic.# .. .lP��? 1.. ...........
Date:. Y/.. �.."......
Owner
S' %11+8� ✓ tWW8AMhWt
Owner's Authorization
Si nature ...........:..
............................................... Lic.#.......................................
Date:. .. (....
Inspection Agency // Inspector Name:
Signature
'---
�p
Buil 'R fficial or designe
Signature ...... ..
...................Lic.# ....C:7�..C.�9 ....
r,cc��
Date:....... �V..!..�.
Aa-04oL�;,
SpecialnspectionForm_2012.doe revised 07109112
LIST OO F SPECIAL NSPEC OO AGE C ES
APPROVAL OF SPECIAL INSPECTORS:
Each special inspection agency, testing facility, and special inspector shall be recognized by the Building Official prior to performing any
duties. Special Inspection agency's listed on this form must be pre -approved and listed on Cupertino's approved Special Inspector's list.
Special inspectors shall carry approved identification when performing the functions of a special inspector. Identification cards shall
follow the criteria set by the California Council of Testing and Inspection Agencies. No personnel changes shall be made without first
obtaining the approval of the Building Official. Any unauthorized personnel changes may result in a "Stop Work Order" and possible
permit revocation. To be pre- approved by the City of Cupertino, refer to the SPECIAL INSPECTION CRITERIA handout. Please allow
two weeks to complete the application process.
The following are the testing and special inspection agencies that will be retained to conduct tests and inspection on this project:
EXPERTISE
FIRM I INSPECTOR INFORMATION
1. Special Inspection (except for
geotechnical)
Firm.........GV.......................................Addr..tj.
4�� � $g
�6�....� ..... C1
���.:................
City��......................................................................
State..".............
....... Zip ..�5193 ...
Telephone..'Y. -TkX f ...
Fax.'Y0.W3 'X.-.8.�......... Emai1611W .. 1 .a3`r'! q..CO
2. Material Testing
Firm......... V..........................................................
Addr........... P...........................................................................
City............. ��..........................................................................................
State ..... '................Zip
.......................
Telephone......................................Fax............................................
Email ..........'.I..............................................
3. Geotechnical Inspections
Firm................................................Addr..*?0
...... f��......K.1............................................
city..................................................................................
State ... C4............
Zip .9i!� 11$ .
Telephone.6091 .`11�6 Fax .... C��'� �. Email.........................................................
4. Other:
Firm .................................. ...................................
Addr............................................ .............................................
City..........................................................................................................
State .......................Zip
......................
Telephone......................................
Fax............................................ Email.........................................................
'All agencies specified on this form must be pre -approved and listed on the City of Cupertino's Approved Special Inspector's List.
SEISMIC REQUIREMENTS (Section 1705.3.6)
Description of seismic -force -resisting system and designated seismic systems subject to special inspections as per Section 1705.3:
The extent of the seismic -force -resisting system is defined in more detail in the construction documents.
Description of main wind -force -resisting system and designated wind resisting components subject to special inspections in accordance with Section
1705.4.2:
The extent of the main wind -force -resisting system and wind resisting components is defined in more detail in the construction documents.
SpecialnspectionForm 2012.doc revised 07109112
SCHEDULE OF SPEML NSPECTMH
SITE
ADDRESS Z(� (�
PROJECT DESCRIPTION:
Notation Used Used in Table:
Column headers:
C Indicates continuous inspection is required.
P Indicates periodic inspections are required. The notes and/or contract documents should clarify.
Box entries:
X Is placed in the appropriate column to denote either "C" continuous or "P" periodic inspections.
-- Denotes an activity that is either a one-time activity or one whose frequency is defined in some other
manner.
Additional detail regarding inspections and tests are provided in the project specifications or notes on the drawings.
VERIFICATION AND INSPECTION C P REFERENCED IBC REFERENCE
STANDARD
INSPECTION OF FABRICATORS
1. ❑ Inspect fabricator's fabrication and quality control 1704.3
procedures.
INSPECTION OF STEEL
1. Material verification of high -strength bolts, nuts and washers.
❑ Identification marking to conform to ASTIM stds
AISC 360,
specified in the approved construction documents.
---
X
Section A3.3 and
applicable ASTM
material standards
❑ Inspect fabricator's fabrication and quality control
X
procedures.
2. Inspection of high -strength bolting:
❑ Snug -tight joints.
---
X
❑ Pretensioned and slip -critical joints using turn -of -nut
with matchmarking, twist -off bolt or direct tension
---
X
AISC 360,
indicator methods of installation.
Section M2.5
1704.3.3
❑ Pretensioned and slip -critical joints using turn -of -nut
without matchmarking or calibrated wrench methods
X
---
of installation.
3. Material verification of structural steel and cold -formed steel deck.
❑ For structural steel, identification markings to conform
_ _
X
AISC 360,
to AISC 360.
Section M2.5
❑ For other steel, identification markings to conform to
Applicable ASTM
ASTM standards specified in the approved
---
X
material standards
construction documents.
❑ Manufacturer's certified test reports.
---
X
SpecialnspectionForm_2012.doc revised 07109112
VERIFICATION AND INSPECTION
C
P
REFERENCED
STANDARD
IBC
REFERENCE
4. Material verification of weld filler materials:
❑ Identification marking to conform to AWS specification
in the approved construction documents.
---
X
AISC 360,
Section A3.5 and
applicable AWS A5
documents
---
❑ Manufacturer's certificate of compliance required.
---
X
---
---
5. Inspection of welding:
a. Structural steel and cold -formed steel deck:
Complete and partial joint penetration groove welds.
X
---
AWS D1.1
1704.3.1
❑ Multipass fillet welds.
X
--
❑ Single -pass fillet welds > 5/16"
X
---
❑ Plug and slot welds.
X
---
❑ Single -pass fillet welds <= 5/16"
---
X
❑ Floor and roof deck welds.
---
X
AWS D1.3
b. Reinforcing steel:
❑ Verification of weldability of reinforcing steel other than
ASTM A 706.
---
X
AWS D1.4 ACI 318:
Section 3.5.2
❑ Reinforcing steel resisting flexural and axial forces in
intermediate and special moment frames, and
boundary elements of special structural walls of
concrete and shear reinforcement.
X
---
❑ Shear reinforcement.
X
---
❑ Other reinforcing steel.
---
X
6. Inspection of steel frame joints details for compliance.-
0 Details such as bracing and stiffening.
---
X
---
1704.3.2
❑ Member locations.
---
X
❑ Application of joint details at each connection.
--
X
VERIFICATION AND INSPECTION
C
P
REFERENCED
STANDARD
IBC
REFERENCE
INSPECTION OF WELDING
1. ❑ Welded studs when used for structural diaphragms.
---
X
---
1704.3
2. ❑ Welding of cold -formed steel framing members.
---
X
3. ❑ Welding of stairs and railing systems.
---
X
SpecialnspectionForm_2012.doc revised 07109112
VERIFICATION AND INSPECTION
C
P
REFERENCED
IBC
STANDARD
IREFERENCE
INSPECTION OF CONCRETE
1. ❑ Inspection of reinforcing steel, including prestressing
___
X
ACI 318: 3.5, 7.1-7.7
1913.4
tendons and placement.
2. ❑ Inspection of reinforcing steel welding in accordance
AWS D1.4 ACI 318:
with Table 1704.3 Item 5b.
3.5.2
3. ❑ Inspection of bolts to be installed in concrete prior to
and during placement of concrete where allowable
X
--
ACI 318: 8.1.3,
1911.5, 1912.1
loads have been increased or where strength design
21.2.8
is used.
4. ❑ Inspection of anchors installed in hardened concrete.
---
X
ACI 318:
1912.1
5. ❑ Verifying use of required design mix.
1904.2.2,1913.2,
---
X
ACI 318:
1913.3
6. ❑ At time fresh concrete is sampled to fabricate
ASTM C 172
specimens for strength tests, perform slump and air
X
---
ASTM C 31
1913.10
content tests and determine the temperature of the
concrete.
ACI 318: 5.6, 5.8
7. ❑ Inspection of concrete and shotcrete placement for
X
_-_
ACI 318: 5.9, 5.10
1913.6, 1913.7,
proper application techniques.
1913.8
8. ❑ Inspection for maintenance of specified curing
--_
X
ACI 318: 5.11-5.13
1913.9
temperature and techniques.
9. Inspection of prestressed concrete:
❑ Application of prestressing forces.
X
---
ACI 318: 18.20
❑ Grouting of bonded prestressing tendons in the
X
-__
ACI 318: 18.18.4
seismic force -resisting system.
10. ❑ Erection of precast concrete members.
--
X
ACI 318: Ch. 16
---
11. ❑ Verification of in -situ concrete strength, prior to
stressing of tendons in posttensioned concrete and
---
X
ACI 318: 6.2
---
prior to removal of shores and forms from beams and
structural slabs.
12. ❑ Inspect formwork for shape, location, and dimensions
X
ACI 318: 6.6.1
---
of the concrete member being formed.
13. ❑ Bolts Installed in Existing Masonry or Concrete
❑ Direct tension testing of existing anchors.
---
X
See ICC ES Reports form special
inspection requirements for proprietary
❑ Direct tension testing of new bolts.
--
X
❑ Torque testing of new bolts.
___
X
products
❑ Prequalification test for bolts and other types of
X
anchors.
_-
14. ❑ Other:
SpecialnspectionForm 2012.doc revised 07109112
REFERENCE FOR CRITERIA
VERIFICATION AND INSPECTION
C
P
IBC
TMS 402/ACI
TMS 402/ACI
SECTION
530/ASCE 5
530/ASCE 6
INSPECTION OF LEVEL 1 MASONRY
1. ❑ Compliance with required inspection provisions of
the construction documents and the approved
---
x
---
---
Art. 1.5
submittals shall be verified.
2. ❑ Verification of fm and FAAc prior to construction
x
___
___
Art. 1.46
except where specifically exempted by this code.
3. ❑ Verification of slump flow and VSI as delivered to
x
___
_
___
Art. 1.513.1.b.3
the site for self consolidating grout.
4. As masonry construction begins, the following shall be verified to ensure compliance:
❑ Proportions of site -prepared mortar.
---
x
---
---
Art. 2.6A
❑ Construction of mortar joints.
---
x
---
---
Art.3.36
❑ Location of reinforcement, connectors,
x
___
___
Art. 3.4, 3.6A
prestressing tendons, and anchorages.
❑ Prestressing technique.
---
x
---
--
Art. 3.68
❑ Grade and size of prestressing tendons and
---
x
"-
---
Art. 2.4B, 2.4Fi
anchorages.
5. During construction the inspection program shall verify:
❑ Size and location of structural elements.
---
x
---
---
Art. 3.31F
❑ Type, size, and location of anchors, including
Sec . 1.2.2(e),
other details of anchorage of masonry to
---
x
---
1.16.1
-__
structural members, frames or other construction.
❑ Specified size, grade, and type of reinforcement,
anchor bolts, prestressing tendons and
---
x
---
Sec. 1.15
Art. 2.4, 3.4
anchorages.
❑ Welding of reinforcing bars.
x
---
---
---
❑ Preparation, construction and protection of
masonry during cold weather (temperature below
___
x
Sec. 2104.3,
Art. 1.8C, 1.8D
40 degrees F) or hot weather (temperature above
2104.4
90 degrees F).
❑ Application and measurement of prestressing
x
___
___
___
Art. 3.66
force.
6. Prior to grouting the following shall be verified to ensure compliance:
❑ Grout space is clean.
---
x
---
---
Art. 3.2D
❑ Placement of reinforcement and connectors and
___
x
---
Sec. 1.3
Art. 3.4
prestressing tendons and anchorages.
❑ Proportions of site -prepared grout and
___
x
__
___
Art. 2.613
prestressing grout for bonded tendons.
❑ Construction of mortar joints.
---
x
---
---
Art. 3.313
7. Grout placement:
❑ Grout placement shall be verified ensure
x
___
___
___
Art. 3.5
compliance.
❑ Observe grouting of prestressing bonded
x
---
---
---
Art 3.6C
tendons.
SpecialnspecdonForm_2012.doc revised 07109112
REFERENCE FOR CRITERIA
VERIFICATION ARID INSPECTION
C
P
IBC
TMS 402/ACI
TMS 402/ACI
SECTION
530/ASCE 5
530/ASCE 6
8. ❑ Preparation of any required grout specimens,
Sec.
mortar specimens, and/or prisms shall be
---
x
2105.2.2,
---
Art. 1.4
observed.
2105.3
INSPECTION OF LEVEL 2 MASONRY
1. ❑ Compliance with required inspection provisions
of the construction documents and the approved
---
x
--
---
Art. 1.5
submittals.
2. ❑ Verification of f m and f nac prior to construction
and for every 5,000 square feet during
---
x
---
---
Art. 1 AB
construction.
3. ❑ Verification of proportions of materials in
premixed or preblended mortar and grout as
---
x
---
---
Art. 1.513
delivered to the site.
4. ❑ Verification of slump flow and VSI as delivered to
x
---
---
---
Art. 1.513.1.b.3
the site for self consolidating rout.
5. The following shall be verified to ensure compliance:
❑ Proportions of site -prepared mortar, grout, and
___
x
___
___
Art. 2.6A
prestressing grout for bonded tendons.
❑ Placement of masonry units and construction of
_-_
x
__
___
Art. 3.313
mortar joints.
❑ Placement of reinforcement, connectors and
---
x
_
Sec. 1.15
Art. 3.4, 3.6A
prestressing tendons and anchorages.
❑ Grout space prior to grouting.
x
---
--
---
Art. 3.21D
❑ Placement of grout,
x
---
--
---
Art. 3.5
❑ Placement of prestressing grout.
x
--
--
---
Art. 3.6C
❑ Size and location of structural elements.
---
x
---
---
Art. 3.3F
❑ Type, size, and location of anchors, including
other details of anchorage of masonry to
x
___
___
Sec.1.2.2(e)
structural members, frames and other
construction.
❑ Specified size, grade, and type of reinforcement,
anchor bolts, prestressing tendons and
---
x
--
Sec. 1.15
Art. 2.4, 3.4
anchorages.
❑ Welding of reinforcing bars.
x
__-
__-
Sec. 2.1.9.7.2,
-_
3.3.3.4 (b)
❑ Preparation, construction, and protection of
masonry during cold weather (temperature below
___
x
Sec. 2104.3,
___
Art. 1.8C, 1.8D
40 degrees F) or hot weather (temperature above
2104.4
90 degrees F).
❑ Application and measurement of prestressing
x
_ _
___
___
Art. 3.613
force.
6. ❑ Preparation of any required grout specimens,
Sec,
mortar specimens, and/or prisms shall be
x
---
2105.2.2,
--
Art. 1.4
observed.
2105.3
SpecialnspectionForm_2012.doc revised 07109112
VERIFICATION ARID INSPECTION
C
p
REFERENCED
IBC
STANDARD IREFERENCE
INSPECTION OF WOOD
1. ❑ Inspect prefabricated wood structural elements and
assemblies in accordance with Section 1704.2.
---
1704.6
2. ❑ Inspect site built assemblies.
--
---
3. Inspect high -load diaphragms:
❑ Verify grade and thickness of sheathing.
--
---
❑ Verify nominal size of framing members at adjoining
panel edges.
---
1704.6.1
❑ Verify nail or staple diameter and length,
---
---
❑ Verify number of fastener lines,
---
---
❑ Verify spacing between fasteners in each line and at
edge margins.
4. ❑ Metal -plate -connected wood trusses spanning 60 feet
or greater: Verify temporary installation
restraint/bracing and the permanent individual truss
---
X
--
1704.6.2
member bracing are installed in accordance with the
approved truss submittal package.
REQUIRED VERIFICATION ARID INSPECTION'OF SOIL
1. ❑ Verify materials below footings are adequate to
X
achieve the desired bearing capacity.
2. ❑ Verify excavations are extended to proper depth and
X
have reached proper material.
---
3. ❑ Perform classification and testing of compacted fill
X
materials.
_
--
Table 1704.7
4. ❑ Verify use of proper materials, densities and lift
thicknesses during placement and compaction of
X
---
compacted fill.
5. ❑ Prior to placement of compacted fill, observe subgrade
X
and verify that site has been prepared properly.
- -
REQUIRED VERIFICATION ARID INSPECTION OF DEEP DRIVEL FOUNDATION ELEMENTS
1. ❑ Verify element materials, sizes and lengths comply
X
---
with the requirements.
2. ❑ Determine capacities of test elements and conduct
X
_
additional load tests, as required.
3. ❑ Observe driving operations and maintain complete
X
---
and accurate records for each element.
4. ❑ Verify locations of piles and their plumbness, confirm
type and size of hammer, record number of blows per
---
Table 1704.8
foot of penetration, determine required penetrations to
X
---
achieve design capacity, record tip and butt elevations
and document any damage to foundation element.
5. ❑ For steel elements, perform additional inspections in
accordance with Section 1704.3.
-_
6. ❑ For concrete elements and concrete filled elements,
perform additional inspections in accordance with
---
---
Section 1704.4.
SpecialnspectionForm 2012.doc revised 07109112
VERIFICATION AND INSPECTION
C
P
REFERENCED
IBC
STANDARD
REFERENCE
7. ❑ For specialty piles, perform additional inspections as
determined by the registered design professional in
---
---
---
Table 1704.8
responsible charge.
REQUIRED VERIFICATION AND INSPECTION OF CAST -IN -PLACE DEEP FOUNDATION ELEMENTS
1 ❑ Observe drilling operations and maintain complete and
X
accurate records for each element.
2. ❑ Verify placement locations and plumbness, confirm
element diameters, bell diameters (if applicable),
lengths, embedment into bedrock (if applicable), and
X
---
---
Table 1704.9
adequate end -bearing strata capacity. Record
concrete or grout volumes.
3. ❑ For concrete elements, perform additional inspections
in accordance with Section 1704.4.
HELICAL PILE FOUNDATIONS
1. ❑ Record installation equipment used, pile dimensions,
X
---
1704.10
tip elevations, final depth, final installation torque.
SPRAYED FIRE-RESISTANT MATERIALS
Physical and visual tests
1. Condition of substrates.
❑ Inspect surface for accordance with the approved fire -
resistance design and the approved manufacturer's
---
---
written instructions.
❑ Verify minimum ambient temperature before and after
application.
---
X
❑ Verify ventilation of area during and after application.
---
X
2. ❑ Measure average thickness per ASTM E605 and
Section 1704.12.4.
---
---
---
1704.12.1
3. ❑ Verify density of material for conformance with the
approved fire-resistant design and ASTM E605. (Ref.
--
---
Section 1704.12.5)
4. ❑ Test cohesive/adhesive bond strength per Section
1704.12.6.
5. ❑ Condition of finished application.
MISCELLANEOUS
1. Mastic and Intumescent Fire -Resistant Coating.
--
---
---
1704.13
2. Exterior Insulation and Finish Systems (EIFS). Water -
resistive barrier coating when installed over a sheathing
---
---
--
1704.14
substrate.
3. Special Cases
---
---
---
1704.15
4. Smoke Control System
---
---
---
1704.16
5. Seismic Resistance
❑ Suspended ceiling systems and their anchorage.
---
---
---
1705.3 [4.3]
SpecialnspeclionForm_2012.doc revised 07109112
VERIFICATION AND INSPECTION
C
p
REFERENCED
IBC
STANDARD IREFERENCE
6. Wind Resistance
❑ Roof cladding and roof framing connections.
---
---
---
❑ Wall connections to roof and floor diaphragms and
framing.
_
---
---
❑ Roof and floor diaphragm systems, including
collectors, drag struts and boundary elements.
❑ Vertical wind -force -resisting systems, including braced
frames, moment frames, and shear walls.
❑ Wind -force -resisting system connections to the
foundation.
❑ Fabrication and installation of systems or components
required to meet the impact resistance requirements
---
---
---
of Section 1609.1.2.
SPECIAL INSPECTION FOR WIND REQUIREMENTS
1. Structural Wood
❑ Inspect field gluing operations of elements of the main
X
-
wind -force -resisting system.
---
1706.2
❑ Inspect nailing, bolting, anchoring, and other fastening
of components within the main windforce-resisting
X
system, including wood shear walls, wood
diaphragms, drag struts, braces and hold-downs.
2. Cold -Formed Steel Framing
❑ Welding of elements of the main wind -force -resisting
X
system.
❑ Inspection of screw attachments, bolting, anchoring,
and other fastening of components within the main
---
1706.3
wind -force -resisting system including shear walls,
---
X
braces, diaphragms, collectors (drag struts) and hold-
downs.
3. Wind -resisting components
❑ Roof cladding.
---
X
---
1706.4
❑ Wall cladding.
---
K
SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
1. ❑ Special inspection for welding in accordance with the
_ _
1707.2
quality assurance plan requirements of AISC 341.
2. Structural Wood
❑ Inspect field gluing operations of elements of the
X
---
seismic-force-resisting system.
❑ Inspect nailing, bolting, anchoring, and other fastening
of components within the seismic -force -resisting
1707.3
system, including wood shear walls, wood
--
X
diaphragms, drag struts, braces, shear panels and
hold-downs.
3. Cold -Formed steel light -frame construction
❑ Welding of elements of the seismic -force -resisting
1707A
system.
SpecialnspectionForm_2011.doc revised 07109112
❑ Inspection of screw attachments, bolting, anchoring,
and other fastening of components within the seismic-
X
force -resisting system including shear walls, braces,
diaphragms, collectors (drag struts) and hold-downs.
4. Storage racks and access floors
❑ Anchorage of storage racks 8 feet or greater in height
_
X
1707.5
and access floors.
5. Architectural components
❑ Inspect erection and fastening of exterior cladding
weighing more than 5 psf and higher than 30 feet
---
X
above grade or walking surface.
❑ Inspect erection and fastening of veneer weighing
more than 5 psf.and higher than 30 feet above grade
---
X
or walking surface.
___
1707.E
❑ Inspect erection and fastening of all exterior non -
bearing walls higher than 30 feet above grade or
---
X
walking surface.
❑ Inspect erection and fastening of all interior non -
bearing walls weighing more than 15 psf and higher
---
X
than 30 feet above grade or walking surface.
6. Mechanical and Electrical Components
❑ Inspect anchorage of electrical equipment for
—
X
emergency or stand-by power systems.
❑ Inspect anchorage of non -emergency electrical
X
equipment.
❑ Inspect installation of piping systems and associated
mechanical units carrying flammable, combustible, or
--
X
---
1707.7
highly toxic contents.
❑ Inspect installation of HVAC ductwork that contains
X
hazardous materials.
---
❑ Inspect installation of vibration isolation systems
X
where required by Section 1707.7.
-_-
7. ❑ Verify that the equipment label and anchorage or
mounting conforms to the certificate of compliance
---
---
___
1707.8
when mechanical and electrical equipment must be
seismically qualified.
8. ❑ Seismic isolation system: Inspection of isolation
X
_-_
1707.9
system per ASCE 7 — Section 17.2.4.8
9. ❑ Obtain mill certificates for reinforcing steel, verify
compliance with approved construction documents,
---
---
---
1708.2
and verify steel supplied corresponds to certificate.
10. ❑ Structural Steel: Invoke the QAP Quality Assurance
1708.3
requirements in AISC 341.
___
-__
11. ❑ Obtain certificate that equipment has been seismically
1708.4
qualified.
___
___
-__
12. ❑ Obtain system tests as required by ASCE 7 Section
1708.5
17.8.
___
---
__-
SpecialnspectionForm_2012.doc revised 07109112