Loading...
14090132.�VL� CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22285 CARTA BLANCA ST CONTRACTOR: SOLARCITY PERMIT NO: 14090132 OWNER'S NAME: HAN YONG-GYU AND MOON SAM-LYEON 3055 CLEARVIEW WAY DATE ISSUED: 09/22/2014 O ER'S PHONE: 4083145472 SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL INSTALL 23 FLUSH MOUNTED PV PANELS (5.865KW) "G License Class 1240 C ic. # WITH o (N) 200 AMP SUB PANEL Contractor Date I hereby affirm tlt I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $12000 I have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 32613051.00 Occupancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter 18 ED INSPECTI upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, City in the g ` ZZ costs, and expenses which may crue against said consequence of 'on ed by: granting of this permit. Addi lly, the applicant understands and will comply with all non -point source re 1 o er the Cupertino Municipal Code, Secti RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is 9.18. tt Signature Date._�� L 1 installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cuperd M icipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 2550 55 , and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date: /t{ permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22285 CARTA BLANCA ST CONTRACTOR: SOLARCITY PERMIT NO: 14090132 OWNER'S NAME: HAN YONG-GYU AND MOON SAM-LYEON 3055 CLEARVIEW WAY DATE ISSUED: 09/22/2014 O ER'S PHONE: 4083145472 SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL 200 AMP SUB PANEL License Class C �p Lic. # A $ g to y Contractor Date y I hereby a m that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $12000 I have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 32613051.00 ( )cc upancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMITEXP + S IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 0 DAYS O + RMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, City in the 180 DAYS F M LAST C LLED INSPE TI QZ� costs, and expenses which may accrue against said consequence of Issued by: Date: ` granting of this permit. Addit pally, the applicant understands and will comply with all non -point source re atio per the Cupertino Municipal Code, Section 9.18. Signature Date O' � � � RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the CupMunicipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 2550 55 , and 25534. r Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date: ZIL. permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature_ Date CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.org i °'SAE PROJECT ADDRESS 22285 Carta Blanca St. 77 3 a, 1 3 — 45-1 OWNERNAMEYg Han PHONE408-314-5472 E-MAIL STREETADDRESS22285 Carta Blanca St. CITY, STATE, ZIP Cupertino,CA,9514 FAX CONTACT NAME Marjan Javanmard PHONE650.477.6430 E-MAIL mjaVanmal'd@solarcity.com STREETADDRESS391 Foster City Blvd CITY, STATE, "'Foster City, CA 94404 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR 9 CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTORNAMESOIarCity Corporation LICENSENUMBER888104 LICENSE TYPE C10 BUS. LIC 4288 0 `'F COMPANY NAMESOIarCity Corporation E-MAIL mjavanmard@solarcity..com FAX STREET ADDRESS 391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 PHONE 650.477.6430 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi -Family ST CTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ NO PROJECT IN FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS I ❑ ELECTRIC VEHICLE CHARGING STATION I ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY): 23 TOTAL VALUATION: $1 2, 000.00 4W+ DESCRH'TION OF WORK Installation (23) rooftop flush mounted solar panel (5.865) kW O L oix-L C e lf,( By my signature below, I certify to each of the following: I am the propertyo er or authorized agent to act on the property er s behalf. 1 have read this application and the information I have provided is correct. I have read t, D -tion of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize r ntatives of Cupertino to enter the above -identified propelfor inspection purposes. Signature of Applicant/Agent: Date: 0 SUPPLEMENTAL IN TION REQUIRED OFFICE USE ONLY W ❑ OVER-THE-COUNTER a. F- Y ❑ EXPRESS U ❑ STANDARD U U ❑ LARGE a ❑ MAJOR PVApp_2011.doe revised 03/16/11 CITY OF CUPERTINO FFF FISTIMATOR - BUILDING DIVISION WdADDRESS: 22285 CARTA BLANCA ST DATE: 09/22/2014 REVIEWED BY: MELISSA APN: 32613 051 __TB P#: 14109'013 `VALUATION: $12,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: p hr's PENTAMATION SOLAR -RES PERMIT TYPE: i WORKL INSTAL 23 FLUSH MOUNTED PV PANELS WITH N 200 AMP SUB PANEL SCOPE 5 )< W NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public works, Fire, sanitary sewer District acnoot n: 6 .wed — N.n nrnl;m;nan, infnrmatinn availahle and are only an estimate. Contact the Dent for addn 7 info. FEE ITEMS (&e Resolution 11-053 Ef' T -'I/13) FEE QTY/FEE Elec. Plan Check 0.0 lirs $0.00 Plan Check Fee: Elec. Permit Fee: IEPERMIT E1 # $236.00 Alternative Energy System 1PHOTOVRES Photovoltaic System Other Elea Insp. E7rsl $48.00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public works, Fire, sanitary sewer District acnoot n: 6 .wed — N.n nrnl;m;nan, infnrmatinn availahle and are only an estimate. Contact the Dent for addn 7 info. FEE ITEMS (&e Resolution 11-053 Ef' T -'I/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 E1 # $236.00 Alternative Energy System 1PHOTOVRES Photovoltaic System Suppl. PC Fee: (j) Reg. 0 OT 0.0 hr's $0.00 PME Plan Check: $0.00 = amps $48.00 Electrical IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Fee -0 Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 �'1i7S;1'l(�IiOfl 1 (7. `i: Administrative Fee: IADMIN $45.00 0 0 Work Without Permit? 0 Yes 0 No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure 0 0 Travel Documentation Fee: ITRA VDOC $48.00 Strong Motion Fee: IBSEISMICR $1.56 Select an Administrative Item Bldy Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $143.56 $284.00 TOTAL FEE: $427.56 Revised: 08/20/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT UL -LISTED POWER -CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY -RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN ECC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. PLOW PLANS (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING (`NITYpEVELOPMENTDEP—'RT",LENT CHECKED B EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, B�jiLDING DIVISION - CUPERTIINO FSB FIRE SET -BACK A SIGN WILL BE PROVIDED WARNING OF THE APPROVC-D DIAT- „L,,,, / (;Lq III GALV GALVANIZED HAZARDS PER ART. 690.17. T;h GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE j„ -ns and specifications MLIST be s,(r .t , +bbyp �� , GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY construction. It is unlawful to k'L�AI�.�ENG I)EY F. HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. ` alterations on same, or to I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL 'ut approval from the Buildi, r, 1)AT3: Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). TI, 'this plan and specification- Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER Tit on to be an a , royal of kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR n kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC ce cr LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN L (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY Pe,: Z2_/ _- i y og 0/ 3 / �y .�. � � C�'PERTINO NEUT NEUTRAL UL LISTING. i NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE Building Department OC ON CENTER UL -LISTED LOCATION PROVIDED BY THE i PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING R POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE RFVI��^VFQ FOR CODE COMPLIANCE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. IANCE Ur S STAINLESS STEEL C Co p Y. d B Rev,ew�� y �j�,,, STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT :1 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET . rt _:. �� PV2 SITE PLAN ' PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE GRAM LICENSE GENERAL NOTES - Cutsheets Attached CE-,IVE CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 X CALIFORNIA BUILDING CODE AND THE 2013 C-10 CALIFORNIA RESIDENTIAL CODE." SEP 2 2 2014 2. ALL ELECTRICAL WORK SHALL COMPLY WITH b THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHI: Cupertino ,"tom-�1 REV BY DATE COMMENTS DATE COMMENTS Pacific Gas and Electric Company UTILITY: CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9503673 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BEUSED FOR THE HAN, YG HAN RESIDENCE Kevin Do ,,;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 22285 CARTA BLANCA ST 5.865 KW PV ARRAY I�� PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: CUPERTINO, CA 95014 /--� 3055 aeurvew Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (23) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV: DATE Son Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650) 638-1028 F:(650) 638-1029 PERMISSION OF SOLARCITY INC. [ABB PVI-5000-OUTD-US-Z-A (408) 314-5472 COVER SHEET PV 1 a 9/18/2014 (866)_SOL-CITY (765-2489) www.solarcity.com 22285 Carta Blanca St PITCH: 18 ARRAY PITCH: 18 MP1 AZIMUTH: 179 ARRAY AZIMUTH: 179 MATERIAL: Comp Shingle STORY: 1 S1 PITCH: 18 ARRAY PITCH: 18 MP2 AZIMUTH: 89 ARRAY AZIMUTH: 89 MATERIAL: Comp Shingle STORY: 1 S1 PITCH: 18 ARRAY PITCH: 18 d MP3 AZIMUTH: 269 ARRAY AZIMUTH: 269 MATERIAL: Comp Shinqle STORY: 1 S1 LEGEND O (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © I DC DISCONNECT & WARNING LABELS A AC AC DISCONNECT & WARNING LABELS 10 DC JUNCTION/COMBINER BOX & LABELS F DISTRIBUTION PANEL & LABELS '. y CUPERT LOAD CENTER &WARNING LABELS BUilding Depu k * ,- O DEDICATED PV SYSTEM METER SP 2 2014 Q STANDOFF LOCATIONS REVIEWED FOR CODE COMPL 1 7T7� CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR Reviewed By: GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r, _-I INTERIOR EQUIPMENT IS DASHED L_J TOTAL ARRAY AREA (SF): 414 SITE PLAN N TOTAL ROOF AREA (SF): 3699 Scale: 3/32" = 1' W E TOTAL ARRAY AREA IS a 11.18 01' 10' 21' iml PERCENT OF TOTAL ROOF AREA CONFIDENTIAL —THE INFORMATION HEREIN JOB NUMBER:S CONTAINED SHALL NOT BE USED FOR THE J[3-9503673 O O PREMISE OWNER: DESCRIPTION: HAN, YG HAN RESIDENCE DESIGN: Kevin Do \\\ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS 22285 CARTA BLANCA ST 5.865 KW PV ARRAY CUPERTINO, CA 95014 �"•.a• I„ SolarCity. MOUNTING SYSTEM: Comp Mount Type C NOODLES ORGANIZATION, EXCEPT IN CONNECTION WITH (((A—�[VVJ Way 3055 Mateo,San CleoCA 94402 THE SALE AND USE OF THE RESPECTIVE (23) TRINA SOLAR # TSM-255PAO5.18 REVDATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME' 408 314-5472 SITE PLAN(688)-SOL-aTY PV 2 C 9/18/2014 T.(650) 638-1028 F:(650) 638-1029 (765-2489) eww.sdarcity.com INVERTER: ABB # PVI-5000-OUTD-US-Z-A SIDE VIEW 01 MPI NTS �H MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" NOTES PORTRAIT 4811 2011 RAFTER C.J. L- 2X6 @ 24" OC 2x6 @16" OC ROOF AZI 179 PITCH 18 STORIES: 1 ARRAY AZI 179 PITCH 18 IComp Shingle PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER (E) 2x6 (E) 2x4 INSTALLATION ORDER X -SPACING (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. Y -CANTILEVER NOTES (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. 24" SHEET: REV: DATE: PV 3 0 9/18/2014 (3) INSERT FLASHING. PORTRAIT 4811 (4) PLACE MOUNT. RAFTER C.J. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. 1 SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 7211 24" SHEET: REV: DATE: PV 3 0 9/18/2014 INVERTER: ABB # PVI-5000—OUTD—US—Z—A PORTRAIT 4811 2011 RAFTER C.J. 2X6 @ 24" OC 2x6 @24" OC ROOF AZI 89 PITCH 18 STORIES: 1 ARRAY AZI 89 PITCH 18 Comp Shingle Building Department I�EVIEO1ED NOR C;C)DE COMPLIANCE Rev,ew �d B y c. . CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9503673 00 rHMAN,mtYG Uutnr HAN�RESIDENCE 22285 CARTA BLANCA ST 5.865 KW PV ARRAY C U P E R TI N 0 CA 95014 PAGE NAME: (408) 314-5472 STRUCTURAL VIEWS Kevin Do UKevi �,,So�arCity MOUNTING SYSTEM: Comp Mount Type C IK—� MODULES: (23) TRINA SOLAR # TSM-255PA05.18 3055 Clearview Way CA 9"0638-1029 T:(650) Son Mateo, (888)-SOL—CITY (765-2489) www.solarcity.com SHEET: REV: DATE: PV 3 0 9/18/2014 INVERTER: ABB # PVI-5000—OUTD—US—Z—A CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J[3-9503673 00 MOUNTING SYSTEM: Comp Mount Type C MODULES: (23) TRINA SOLAR # TSM-255PA05.18 INVERTER: ABB # PVI-5000-OUTD-US-Z-A HAN, YG 22285 CARTA BLANCA ST CUPERTINO, CA 95014 (408) 314-5472 UPLIFT CALCULATIONS 09.11.2014 SolarCity SleekMountTMPV System Version #38.9 Structural Desian Software Project Information & Table Of Contents Risk Category: II PV System Type SolarCity SleekMount"^ Comp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 180 Rafter Spacing 24" O.C. PV System Module Orientation Landscape and Portrait PV Module Area 405 sf PV Module Width 39" PV Module Length 65" Standoff Attachment Hardware Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq: 7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig. 30.4-2A113,?C-5A,113 Mean Roof Height h 15 ft Section 26.2 Effective Wind Area 1 Module A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kid 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A?BIC-5" Ext. Pressure Coefficient Down GC Down 0.45 Fig. 304-2A./Bi C-5A,IB Design Wind Pressure p p = gh GC Equation 30.4-1 Wind Pressure Up p(up) -19.6 psf Wind Pressure Down down 16.0 psf Allowable Standoff Spacings X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not -Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff Tactual -196 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capadty DCR 39.2% Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Not -Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -217 lbs Uplift Capacity of Standoff T-allos••i 500 lbs Standoff Demand/Capadty DCR 43.4% HAN RESIDENCE 5.865 KW PV ARRAY PAGE NAME: UPLIFT CALCULATIONS Kevin Do SHEET: REV: DATE: PV 4 a 9/18/2014 JPERTINO 1uildlncg Department '"L't,E COMPLIANCE solarCity� 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www,solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N 8 GEC TO N GROUND ROD () # () Panel Number: GE MAIN, SQUARE D SU Inv 1: DC Ungrounded INV 1 - 1 ABB PVI-5000-OUTD-US-Z-A ( ) # - 3 TRINA SOLAR � TSM-255PA05.18 �) CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1005990892 FCI Inverter; Zigbee 5000W, 240V, 96.5% PV Module; 5W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled C-10 INV 2 Underground Service Entrance Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL Multiple Main Breakers (6 or fewer) ADJUST MIN. ACTIVATION VOLTAGES! SolarCity BRYAN Inverter 1 IND A 6 (N) 200A Load Center 5 ABB 4 Vstart = DEFAULT PVI-5000-OUTD-US-Z-A MP 1 1x11 12P 30A/2P L1 zaov------- --------------+---- -B _J - - L2 DC+ F Vstart = 184V 20OA/2P DC_ 3 MP 1: 1x6 Ar---- ------- - - - - - - ___ ___-_____------ _EGC._--DC+ GEC TN DG MP 2: 1x6 6 I z GND _ _ EGC ---- --------- ------------ ■ -- T ----cc --------------� I I (1 )Conduit Kit; 3/4' EMT N i I EGCIGEC Z U --- GEC ALOADS TO 120/240V SINGLE PHASE UTILITY SERVICE I I I I CUPERTIN^ Voc* = MAX VOC AT MIN TEMP OTT (2)Bumd_y gg BIT2/0 l MultrCable Connector, 2 Port R ✓ (1)CUTLER-HAMMER # BR230 PV BACKFEED BREAKER Breaker, 30A/2P, 2 Spaces AC JY (1)SolarCit # 4 STRING JUNCTION BOX ep 2x2 S�RMGS, UNFUSED, GROUNDED - (1)Ground Rod; 5/8' x 8', Copper - (1)CUTLER-HAMME pp BJ2200 Breaker, 200AV, 4 Spaces ✓ - (i) BRoad 200 0020/24OV, _ 1 ,' ary omT# tBR1 eq NEMA 3R ��EVIEWED �: GR CODE COMPLIANCE Kev•evvea BY ..� 17FT�t/ � 1 AWG #2/0, THWN-2, Black -(l)Conduit Kit; 1-1/2' EMT ©INS (1) AWG #2/0, THWN-2, Black TAPE WIRE IN RED TAPE O (1)AWG #10, THWN-2, Black (1 )AWG #10, THWN-2, Red O (1)AWG #8, THWN 2, Block Voc* = 250.09VDC Q (1) AWG #8, THWN 2, Red Vmp 183 VDC Isc = 17.84 ADC Imp= 16.72 ADC (2 )AWG #10, PV WIRE Black O (1)AWG #10, Solid Bare Copper EGC Voc* = 458.49VDC Isc = 8.92 ADC Vmp = 335.5 VDC Imp= 8.36 ADC Irt (1 ) AWG #2/0, THWN-2, Block Neutral Vmp =240 VAC Imp = N/A AAC -(1)AWG #6, THWN-2, Green . EGC...-(2)AWG #2/0, THWM-2, Blade (WFRL).. . _ .. _ L L LLLL•�_==LLLL (1 ) AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp = 23 AAC ..-(1)AWG #B,,TItWN-2, Green_ _ . EGC/GEC.-(1)Gonduit.Kit;.3/4',EMT. _ .. , . _ . (1 AWG #10, THWN-2, Green EGC (1 AWG #10, THWN-2, Black Voc*=458.49VDC Vmp 335.5 VDC Isc =8.92 ADC Imp= 8.36 ADC ��rr"' (4 AWG #t0, PV WIRE, Black O Voc*=250.09VDC Isc =8.92 ADC Vmp = 183 VDC Imp= 8.36 ADC ®� (1 )AWG #10, THWN-2, Red = Isr� (1 )AWG #10, Solid Bare Copper EGC (1)AWG #10, THWN-2, Green EGC LJ CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: J B- 9503673 0 0 PREMISE OWNER. HAN, YG DESCRIPTION: HAN RESIDENCE DESIGN: Kevin Do INN\�� /,1" SolarCity. MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C� 22285 CARTA BLANCA ST 5.865 KW PV ARRAY CUPERTINOATION, CA 95014 MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH , THE SALE AND USE OF THE RESPECTIVE (23) TRINA SOLAR # TSM-255PA05.18 PAGE NAME 3055 georview Way san Mateo, CA 94402 SHEET: REV DATE THE WRITTEN PERMISSIONITY EOFIPSOLARCITY INC. 408 314-5472 () THREE LINE DIAGRAM PV 5 0 9/18/2014 29 (688) (SOL,CITY (765-2489) 638-1028 �rww.soladty.com INVERTER. ABB PVI-5000-OUTD-US-Z-A Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: PHOTOVOLTAIC AC;,—� (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CUPERTWO BUlidln a 9 Department ?',u111 4 rop. CODE COMPLIANCE /l (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOTBE USED FOR ��.��T� 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo, CA 94402 N WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set oi1�� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SoiarCity.l (888)-SOL-CCFY(765-2489)www.solarcty.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution is optimized to achieve superior strength and aesthetics while minimizing roof disruption and labor. The elimination of visible rail ends and mounting clamps, combined with the addition of array trim and a lower profile all contribute to a more visually appealing system. SleekMount utilizes Zep CompatibleTM modules with strengthened frames that attach directly to Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of standoffs required. In addition, composition shingles are not required to be cut for this system, allowing for minimal roof disturbance. • Utilizes Zep Solar hardware and UL 1703 listed Zep CompatibleTM modules • Interlock and grounding devices in system UL listed to UL 2703 • Interlock and Ground Zep ETL listed to UL 1703 as "Grounding and Bonding System" • Ground Zep UL and ETL listed to UL 467 as grounding device • Painted galvanized waterproof flashing • Anodized components for corrosion resistance • Applicable for vent spanning functions Components A 5/16" Machine Screw B+ Leveling Foot C, Lag Screw D Comp Mount EComp Mount Flashing SolarCity SleekMountTM - Comp — SolarCityJanuary2013 Ne"', /rte LISTED SolaOtym January 2013 Installation Instructions 0 Drill Pilot Hole of Proper Diameter for Fastener Size Per NDS Section 1.1.3.2 ® Seal pilot hole with roofing sealant ® Insert Comp Mount flashing under upper layer of shingle ® Place Comp Mount centered upon flashing ® Install lag pursuant to NDS Section 11.1.3 with sealing washer. ® Secure Leveling Foot to the Comp Mount using machine Screw 0 Place module CUPERTINO auilding DePartment w ��L4';EiNIEi! F� k C UDE C,ONIPLANCE Re, ievv6d By 1 ;� Mono Multi Solutions TSM- PA05.18 THE TRINAMOUNT MODULE 60 CELL MULTICRYSTALLINE MODULE WITH TRINAMOUNT FRAME 240-26OW POWER OUTPUT RANGE 710 10171 MAXIMUM EFFICIENCY 0--+317o POWER OUTPUT GUARANTEE As a leading global manufacturer of next generation photovoltaic products, we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited www.trinasolar.com Trinasolar Smart Energy Together Our most versitile product • Compatible with all major BOS components and system designs �- One of the industry's most trusted modules • Over 2 GW sold across all major global markets • Field proven performance Highly reliable due to stringent quality control Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyong certification requirements Certified to withstand challenging environmental ®conditions • 130 km/hr wind load (2400 Pa) • 900 kg snow load per module (5400 Pa) LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Warranty W00% Additional Valu 90% a from Trina Salor', "near warranty 0 O BO% Years 5 10 IS 20 25 ■ Ir ,,,.,, ■ Trina Solar TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE DIMENSIONS OF PV MODULE TSM-PA05.18 E O 94Tmm �unciroN eox AinEP2AR TSM -240 a e 9x12 INSi LLLING NqE j TSM -250 ft TSM -260 Y PA05.18 3 PA05.18 6 4.3GROUNDINGMOLE PA05.18 A A 12 -DRAIN HOLE 250 255 m 0 a 3 3 812MM Idu Back View W v H I-V CURVES OF PV MODULE TSM -245 PA05.18 I o.- 9.40 e.- -7.- 800W/m2 6- m 5m U 4m 3.01 2.m 200W/m2 lm _ 0- 0.40 10.00 2000 30.40 40.00 Voltage(V) ELECTRICAL DATA @ NOCT TSM -240 TSM -245 TSM -250 TSM -255 TSM -260 ELECTRICAL DATA @STC PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Peak Power Watts-PMAx wp) 240 245 250 255 260 Power Output Tolerance-PMAx (%) 0/+3 0/+3 0/+3 0/+3 0/+3 Maximum Power Voltage-VMP (V) 29.7 30.2 30.3 30.5 30.7 Maximum Power Current-IMPP (A) 8.10 8.13 8.27 8.36 8.47 Open Circuit Voltage-Voc (V) 37.3 37.5 37.6 37.7 37.9 Short Circuit Current-Isc (A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency rlm (%) 14.7 15.0 15.3 15.6 15.9 STC: Irradiance 1000 W/m2, Cell Temperature 25°C, Air Mass AM1.5 according to EN 60904-3. Average efficiency reduction of 4.5% at 200 W/m2 according to EN 60904-I. ELECTRICAL DATA @ NOCT TSM -240 TSM -245 TSM -250 TSM -255 TSM -260 Module dimensions PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Maximum Power-PMAx (Wp) 174 178 181 184 188 Maximum Power Voltage-VMP (V) 26.6 26.8 27.0 27.2 27.4 Maximum Power Current-IMPP (A) 6.55 6.64 6.70 6.77 6.86 Open Circuit Voltage (V)-Voc (V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current (A)-Isc (A) 7.04 7.10 7.25 7.31 7.37 NOCT: Irradiance at 800 W/m2. Ambient Temperature 20°C. Wind Speed 1 m/s. MECHANICAL DATA Solar cells Multicrystalline 156 x 156 mm (6 inches) Cell orientation 60 cells (6 x 10) Module dimensions 1650 x 992 x 40 mm (64.95 x 39.05 x 1.57 inches) Weight 18.6 kg (41.0 Ibs) Glass High transparency solar glass 3.2 mm (0.13 inches) Backsheet White Frame Black Anodized Aluminium Alloy with Trinamount Groove J -Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm2 (0.006 inches2), 1100 mm (43.3 inches) Connector Original MC4 TEMPERATURE RATINGS MAXIMUM RATINGS Nominal Operating Cell 45OC (t2OC) Operational Temperature-40-+85OC Temperature (NOCT) Maximum System 1000V DC(IEC)/ Temperature Coefficient of PMAx - 0.43%/OC Voltage 600V DC(UL) Temperature Coefficient of Voc -0.32%/OC,. cSeries Fuse Rating. t ,1����1N® Temperature Coefficient of Isc 0.047%/°C: -F ;";I Building Dep rtmer _ WARRANTY 10 year Product Workmanship Warranty L,. `7�•rJ ` ` 25 year Linear Power Warranty `' 1 (Please refer to product warranty for details) REVIEWED `Evl IED FOR. CODE COMP ANC CERTIFICATION Reviewed By � ,�� 40PACKAGING CONFIGURATION c ry.�_s; _ \ � O• c . Modules per box: 24 pieces pllev= Modules per 40' container: 672 pieces c Srata V CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. CAM Trinasolar 02013 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to s Change without notice. Smart Energy Together 7y Designed for residential and small The wide input voltage range Highlights: commercial PV installations, this makes the inverter suitable to low — Single phase and split phase output inverter fills a specific niche in the power installations with reduced grid connection. ABB product line to cater for those string size. — Wide input range for increased installations producing between The transformerless operation offers stringing flexibility. 5kW and 20kW. high performance efficiencies of up to — The high speed and precise MPPT < 2% 97.1%. algorithm offers real time power This inverter includes dual input Free remote monitoring capability tracking and improved energy section to process two strings with available with every installation. This harvesting. independent MPPT. enables homeowners to view their — Outdoor NEMA 4X rated enclosure The high speed and precise MPPT energy production and offers installers for unrestricted use under any algorithm offers real-time power a proactive and economic way of environmental conditions. tracking and energy harvesting. maintaining and troubleshooting the — Integrated DC disconnect switch Flat efficiency curves ensure high system. in compliance with international efficiency at all output levels ensuring Standards (-S Version). consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. Power and productivity „ 10 111 for abetter world"" P%1P1P Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types Type code Input side Nominal output power Maximum output power ....................................................................................................... Rated grid AC voltage Input side (DC) Number of independent MPPT channels Maximum usable power for each channel ....................................................................................................... Absolute maximum voltage (Vmax) ....................................................................................................... Start-up voltage(Vstart) .............................................. Full power MPPT voltage range Operating MPPT voltage range Maximum current (ldcmax) for both MPPT it ....................................................................................................... Maximum usable current per channel ........................................................................11 a ......................... Number of wire landing terminals per chann Array wiring termination Output side (AC) Grid connection type Adjustable voltage range (Vmin Vmax) 1111. .. ........ Grid frequency ....................................................... -............................................. Adjustable grid frequency range Maximum current (I °) A ......... ......... ........ Power factor Total harmonic distortion at rated power ............ ........ ......... Contributory fault current' 1111 ... . ............._......... Grid wiring termination type Input Reverse polarity protection Over -voltage protection type PV array ground fault detection Output Anti-islanding protection Over -voltage protection type Maximum AC OCPD Rating .... . Remote monitoring (1XRS485 incl.) Wired local monitoring (1xRS485 incl.) Environmental Ambient air operating temperature range Maximum operating altitutde without derating 2. inverter can apply that much current - Breaker will open 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD PVI-5000-OUTD-US PVI-6000-OUTD-US 5 . _ _ _..1.11.1.... 1 11,,.1.... 208V 36.25 A 25 63A k, pressure clamp, AWG16-AWG6 10/2W 10/2W Split,0/3W ' 10/2W 4V 304V 183V -228V :. 211V -264V . 244V -304V 11 11 1111 ................. 60Hz ........._.. .........1....1 1111. ................................................................................................................................... 57-60 5Hz 20Amas 30Anv,s...... 28AaMs . .. ..................... 1111.24,.4.s 1111.. > 0.995 < 2% .............................................. .75 A / 36.25 A / 36.5 A / 31.75 A 2.45A°k 25.63A aMs 1111. _.25.81 A' ......... 22A5AR° _..,.. Vanstor, 2 for each channel ....... !t_ v & !- R C f N0 C p Riso and Dynamic GFDI (requires floating arrays) c� Jllding Department 47 requirements Meets UL 1741/IEEE1547 requirements Vanstor, 2 (L, - L2 / L, - G) 25A 40A.... 35A 30A............ ......................................97.1 96.5% 96%�q L..Y.Yr . ° 96 5% ..... ;play Graphic display `'!,'� C.,OMPL1r`NC:E <0.6W_.._ r FiG.y 16 charactersx 2 lines LCD display -13°F to +140°F (-25°C to +60°C) ° r co + derat 40°F to +176°F (-40°C to +80 C) 40°F tc 0-100% RH condensino 0-1 < .... 50 db (A). 91 m .................. 6560 ft (2000 m)