Loading...
B-2016-1913CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1913 22025 CREEKSIDE CT.CUPERTINO, CA 95014-1103 (326 39 039) RICH MATHERS CONSTRUCTION INC LOS ALTOS, CA 94023 OWNER'S NAME: BHORKAR ABHAY AND MODAK MANSI DATE ISSUED: 08/08/2016 OWNER'S PHONE: PHONE NO: (650) 941-821$ LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class GENERAL BUILDING CONTRACTOR Lic. #674167 Contractor RICH MATHERS CONSTRUCTION INC Date 11/30/2016 X BLDG —ELECT _PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing X— MECH X RESIDENTIAL _ COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: ADD 129 S.F. TO EXTEND KITCHEN & ADD (I) BATH; I hereby affirm under penalty of perjury one of the following two declarations: RECONFIGURE/REMODEL 1,138 S.F. AREA. REPLACE/RELOCATE 1. 1 have and will maintain a certificate of consent to self-insure for Worker's HVAC Compensation, as provided for by Section 3700 of the Labor Code, for the REV #1 - STRUCTURAL CHANGES TO CEILING FRAMING IN performance of the work for which this permids issued. LIVING ROOM- ISSUED 8131/2016 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued, Sq. Ft Floor Area: 129 Valuation: $175000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 326 39 039 Deferred Submittal (R-3),R-3 (Custom) representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs; and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signature Date Date Issued by: Abby A e� nde OWNER-BUILDER. DECLARATION Date: 08/08/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is i. 11 as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code): 2. 1, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Scc.7044, Business & Professions Code). Date: I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. I have and will. maintain a Certificate of Consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I Will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the a. I certify that in the performance of the work for which this permit is issued I Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. lf, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agent: APPLICANT CERTIFICATION Date: I certify that I have read this application and state that the above information is correct. I agree. to comply with all city and county ordinances and state laws CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulationsper the Cupertino Municipal ARCHITECT'S DECLARATION 1 understand my plans shall be used as public records. Code, Section 9.18. Licensed Signature Date Professional CUPERTINO M NEW CONSTRUCTION CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - building0cuDertino.org AT)DITIOW AT.TFRAT6V/TT ..'An6al— PROJECT ADDRESS ei cok— �( APN I _ OWANISNAME I H AA -Y 443b PtAA6,1 SVNQR� P_ �4P81- Z-va (0 F—MAW STREET ADDRESS Zz!5 64-51PL61>5 CV14.,—, Cz�,ag, ID/if, FAX CONTACT NAMEPHONE E -MAD STREET ADDRESS 0 5, r&j C1 CIT Y, STATE, ZIP A -L71 - 0 5 Z:_3 FAX66D _.?Ll I 13 OWNER CI OWNM-13UMDER noWNERAGWr DeCONTRACTOR 0 CONTRACTORAGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME —7LcENswrq , &-714 LICENSE TYPF�; BUS. LIC 4 12, COMP ANYNAhE FAX ARCHITECT/ENGINEERNAME LICENSE NUMBER BUS. LIC A COMPANY NAME E-MAIL FAX STREET ADDRESS crrV, STATE, ZIP PHONE DESCRIPTION OF WORK F(LAM 6 EXISTINGUSE PROPOSED USE CONSTR_ TYPE ASTORIES USE TYPE OCC. SQ_FT. VALUATION (t) EXISTG FLOOR DEMO TOTAL AREA RE A AREA . I NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA RTMODELAREA PORCHAItEA DECKAREA TOTALDECK/PORCHAUA GARAGEZ07BM I 4DWELLINGUNITS: ISASECONDUNIT []YES BEINGADDED? SECOND STORY OYES ADDITION? 13NO []NO PR&APPLICATION 0 YES IF YES, PROVIDE COPY OF ISTHE ULDGAN 13 YES RECEIVED BY, TOTAL VALUATION: PLANNING APPL # [3NO PLANNING APPROVAL LETTER EICHLERHOMEY ! [3 NO By my signature below, I certify to each of the following: I am the property towner or authorized agent to act on the property owner's behalf I have read this application and the information I have provideditcorrect. I Vvve read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to build' nstru tion 10 representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicam/Agem: Date: 1 I-zo I Ifle SUPPLEMENTAL INFO `�TIO7 REQUMED PLAN - VUECKTYPV RCIT3TING SUP New SFD or Multifamily dwellings: Apply for demolition permit for n OVER THE -COUNTER, 0 BUILDINGPLANUVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. 0 MUESS PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure 11 STANDARD ❑ PUBUCWORKS To—rm. if any Hazardous Materials are being used as part of this projec t. 0 LARGE 0FIRE DEPT_ — Copy of Planning Approval Letter or Meeting with Planning prior to 0 mmou 0 SANITARY SEWER DISTRICT submittal of Building Permit application. 11 ENVIRONMENTAL HEALTH BIdgApp_M1 L doe revised 06121111 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1913 22025 CREEKSIDE CT CUPERTINO, CA 95014-1103 (326 39 039) RICH MATHERS CONSTRUCTION INC LOS ALTOS, CA 94023 OWNER'S NAME: 13HORKAR ABRAYAND MODAK MANSI OWNER'S PHONE: 408-242-2169 LICENSED CONTRACTOR'S DECLARATION License Class B Lic. # 7f 4167 Contractor RICH MATHERS QQNSTRi 1CTION INC Date 11/30/2016 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: i. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2: I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code„ for the performance of the work for which this `� pe`rinit is issued. APPLICANT CRTIFI ATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned, property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applic� t understan and will comply with all non -point source regulations Tr he Cupertin Mun' 'pal Code, Section 9,18. Signature Date/ /8 8 2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (See.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 8/8/2016 ISSUED: 08/08/2016 NO: (650) 941-8218 PERMIT INFO: X BLDG —ELECT -PLUMB X MECH X RESIDENTIAL COMMERCIAL DESCRIPTION: 129 S.F. TO EXTEND KITCHEN & ADD (N), BATH; DNFIGURE/REMODEL 1,138 S.F. AREA. REPLACE/RELOCATE Ft Floor Area: 129 1 Valuation: $175000.00 APN Number: Occupancy Type: 326 39 039 R-3 (Custom) PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. by: Abby Ayendc Date: REROO All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 8/8/2016 ALL ROOF COVERINGS TO BE CLASS "A" HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with theCupe Municipal Code, Chapter 9.12 and the Health & Safety Code, cti s 25505, 25533 25534. Owner or authorized agent• Date: 8/8/2016 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed CUPERTINO Address Lei COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 buildingp_cupertino.org PERNUT CANNOT,BE FINALED AND -COMPLETED UNTIL THIS CERTIFICATE HAS BEEN AND I2T{ 12NED TO THE BUILDING DIVISION PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000,00, CRC Section R314 and CSC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM _ Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling "unit including basements X X _ Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units,, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by,means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. t, ,. .a 11 n fn nmmWith tha tarm.c and rnnrlitions of this statement Owner (or Owner Agent'Name: ` -- d � )bie �v"�� Si nature.................................................................... Date: ................... ................ _s) Contractor Name: IC�k, Plat l�- 9 Lic.#6 Date:.. IQ....c. Signature. �:...................................................................,..................... .............. Smoke and CO fonn.doe revised 03/18114 Owner Name WATER -CONSERVING F - OWNER CERTIFICATE OCOMPLIANCE. COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 77.7-3228 • FAX (408) 777-3333 . building aacupertino.orq Permit No l' I Address 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. % No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom_ of form. 12 No Go to Question 4. 4. Is your real property built and available for use or, occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. j1 Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: My property is a single family-residbntial real property. See Civil Code Section 1101.4. Ori and after January 1, 2014, building alterations or improvements shall require _all- non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. _ On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the followinz pale. . , , I V A Owner or Owner Agent's Signature: Z--- A -Z" `` - — Y Date: / 'IT / " / Upon completing and signing this Certificate, please return it to the Building Division in order to nnai your ouuaing permit. SB407 2015.doc revised 08/26/15 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure sho�nl, it is not required to be upgraded. SB407 2015.doc reVised 08/26/15 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixture/ (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CFC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential .Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush' Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi . Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum .0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets - Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 .gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure sho�nl, it is not required to be upgraded. SB407 2015.doc reVised 08/26/15 CALGREEN SIGNATURE DECLARATIONS Project Name: Abhay Bhorkar and Mansi Modak project residence Project Address: 22025 Creekside Ct., Cupertino, CA., 95014 Project Description. Add'€tion at the (E) Kitchen / new hath, alteration to hal[, HVAC, lighting, floorin ............. SECTION f - DESIGN VERIFICATION Complete all lines of Section 1 — "Design Verification" and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the xoject plans and will be implemented into the project in accordance with the requirements set forth in the 2013 California Leen Building Standards Code as adopted by the City of Cupertino. 7-1 Owner's Signature Date Abhay Bhorkar Owner's Name (Please Print) 7/27/16 Design Professional's Signature Date David Torras Design Professional's Name (Ple a Pr 07/29/2016 Signature of License Professional r ponsib for compliance Date Jamshid (Jam) Hezar-AI i nce 24 Ti e- Calgreen Inspector#8099390 (530) 902-4387 Name of License Profession responsible f CalGreen compliance (Please Print) Phone a24t@att.net Email Address for License Professional responsible for CalGreen compliance SECTION 2 - IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I tiave inspected the work and have received sufficient documentat'�)n to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Cade as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Jamshid (Jam) Hezar- Alliance 24 Title-Calgreen Inspector # 8099390 Name of License Professional responsible for CalGreen compliance (Please Print) a24t@att.net Email Address for License Professional responsah��_f�� � ]Green Building Department Date (530) 902-4387 Phone Page 5of5 REVIEWED FOR CODE COMPLIANCE CalGreen_2014.docrevised 11104114 Reviewed By:Arnold Hom Date: 08/02/16 CUPERTINO PURPOSE: CALGREEN RESIDENTIAL CHECKLIST - MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(alcupertino.org The 2013 CalGreen Code applies to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size and also applies to all new low-rise residential buildings, high-rise residential buildings, or both. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: Abhay Bhorkar and Mansi Modak project residence Project Address: 22025 Creekside Ct., Cupertino, CA., 95014 Project Description: Addition at the (E) Kitchen / new bath, alteration to hall, HVAC, lighting, flooring Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the California Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. Column 2 Column 3 MANDATORY FEATURE OR MEASURE Project Verification Reauirements Planning and Design - Site Development 4.106.2 Storm water drainage and retention during construction. A plan is developed and implemented to manage storm water drainage during ❑ ❑ construction. 4.106.3 Grading and paving. The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how Q ❑ site grading or a drainage system will manage all surface water flows. CUPERTINO Building Department REVIEWED FOR CODE COMPLIANCE Page 1 of 5 Reviewed By:Arnold HOM CalGreen_2014.doc revised 11/04/14 Date: 08/02/16 General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: ❑ 4.303.1.3.2 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank -type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specifications for Tank -type Toilets. ❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. ❑ 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ® 4.303.1.3.2 Multiple Showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. ❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. ® 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards r in Table 1401.1 of the California Plumbing Code. _ CUPERTINO Page 2 of 5 REVIEWED FOR CODE COMPLIANCE Reviewed By:Arnold HOm Date: 08/02/16 K 701 U 701 CalGreen_2014.doc revised 11/04/14 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the time of final inspection shall be weather -based. 4.304.1.1 Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. ❑ 4.304.1.2 Weather -based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controller(s). Soil moisture -based controllers are not required to have rain sensor input. A4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY Enhanced Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, a construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual. At the time of final inspection, an operation and maintenance manual shall be provided to the building occupant or owner. A4.5 ENVIRONMENTAL QUALITY Fireplaces 4.503.1 General. Install only a direct -vent sealed -combustion gas or sealed wood -burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical equipment during construction. Duct openings and other related air 0 distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be compliant with VOC limits. CUPERTINO 4.504.2.3 Aerosol paints and coatings.attfl0tlgoDepado" Ls shall be compliant with product weighted for ROC and other toxic 0 compounds. REVIEWED FOR CODE COMPLIANCE Page 3 of 5 Reviewed By:Arnold Hom CalGreen_2014.doc revised 11/04/14 Date: 08/02/16 4.504.2.4 Verification. Documentation shall be provided to verify that compliant VOC limit finish materials have been used. 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with VOC limits. 4.504.4 Resilient flooring systems. Eighty (80) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools (CHPS) Low -emitting Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall 0 comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete slab foundation. Required vapor retarders and capillary breaks are also required to comply with CalGreen Section 4.505.2.1. 4.505.3 Moisture content of building materials. Moisture content of building materials used in wall and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the building are provided in every bathroom. Environmental Comfort 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS Qualifications 702.1 Installer training. HVAC system installers are trained and certified in the proper installation of HVAC systems. 702.2 Special inspection. The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the 0 discipline they inspect and verify. Verifications 703.1 Documentation. Verification of com fiance with CALGreen may include construction documents, plans, bp,ns, bpr I inspection tt��f1Tdt'cing certification, reports, or other m o ccep�bf� agency which show substantial conforma rRw1htiag\0s nmestbll be submitted to the Building Department a mentation of all required measures and prior to final inspection appRAWED FOR CODE COMPLIANCE Page 4 of 5 Reviewed By:Arnold HOm CalGreen_2014.doc revised 11/04/14 Date: 08/02/16 Project Name Project Address Project Description CALGREEN SIGNATURE DECLARATIONS Abhay Bhorkar and Mansi Modak project residence 22025 Creekside Ct., Cupertino, CA., 95014 Addition at the (E) Kitchen / new bath, alteration to hall, HVAC, lighting, floorin SECTION 1 - DESIGN VERIFICATION Complete all lines of Section 1 — "Design Verification" and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Owner's Signature Date Abhay Bhorkar Owner's Name (Please Print) Design Professional's Signature Date David Torres Design Professional's Name (Please Print) Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance SECTION 2 - IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Name of License Professional responsible for CalGreen compliance (Please Print) Email Address for License Professional Page 5 of 5 REVIEWED FOR CODE COMPLIANCE Reviewed By:ArnOld HOm Date: 08/02/16 Date Phone CalGreen_2014.doc revised 11/04/14 ADDITIONS LOCATED IN FLOOD HAZARD AREAS COMMUNITY DEVELOPMENT DEPARTMENT • PUBLIC WORKS DEPARTMENT 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.org CUPERTINO BACKGROUND The City of Cupertino establishes requirements for the prevention of flood damage in Chapter 16.52 of the Cupertino Municipal Code. The purpose of this policy is to further clarify the requirements for additions to buildings and structures located within the boundaries of a flood hazard area. DEFINITIONS: ADDITION: An extension or increase in floor area or height of a building or structure. ALTERATION: Any construction or renovation to an existing structure other than repair or addition that requires a permit. Also, a change in a mechanical system that involves an extension, addition or change to the arrangement, type or purpose of the original installation that requires a permit. POST -FIRM BUILDING: A building for which construction or substantial improvement occurred after December 31, 1974, or on or after the effective date of the initial Flood Insurance Rate Map (FIRM) for the community. PRE -FIRM BUILDING: A building for which construction or substantial improvement occurred on or before December 31, 1974, or before the effective date of the initial Flood Insurance Rate Map (FIRM) for the community. SUBSTANTIAL IMPROVEMENT: "Substantial improvement" means any repair, reconstruction or improvement of a structure, the cost of which equals or exceeds fifty percent of the market value of the structure either: 1. Before the improvement or repair is started; or 2. If the structure has been damaged and is being restored, before the damage occurred. For the purposes of this definition "substantial improvement" is considered to occur when the first alteration of any wall, ceiling, floor or other structural part of the building commences, whether or not that alteration affects the external dimensions of the structure. The term does not, however, include either: 1. Any project for improvemM stru�t�� t"so with existing state or local health, sanitary, or safety codesions w'h� arly necessary to assure safe living conditions; or Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By:Arnold Hom FloodMitigation_2015.doc revised 09101115 Date: 08/02/16 2. Any alteration of a structure listed on the National Register of Historic Places or a State Inventory of Historic Places. EXAMPLES OF SUBSTANTIAL IMPROVEMENT Substantial Improvement to an existing building may be the result of an alteration to an existing building, an addition to an existing building, or a combination of both. The following examples will clarify how the Cupertino determines if an improvement to an existing building is considered a substantial improvement. EXAMPLE 1: 100% alteration of an existing 1000 s.f. building; No addition. Assume: Market Value for existing structure = $150/s.f. Alteration of existing structure = 50% cost of Market Value = $75/s.f Calculate: Market Value of Existing Structure = 1000 s.f. x $150/s.f. = $150,000 Improvement Value = 1000 s.f. x $75/s.f. = $75,000 Value Increase (%) = 50% Market Value [Scope is consider Substantial Improvement] EXAMPLE 2: 500 s.f. addition to an existing 1000 s.f. building; No alteration. Assume: Market Value for existing structure = $150/s.f. Construction Valuation of Addition = $150/s.f Calculate: Market Value of Existing Structure = 1000 s.f. x $150/s.f. = $150,000 Improvement Value = 500 s.f. x $150/s.f. = $75,000 Value Increase (%) = 50% Market Value [Scope is consider Substantial Improvement] EXAMPLE 3: 300 s.f. addition to an existing 1000 s.f. building; Alteration to 40% of existing structure. Assume: Market Value for existing structure = $150/s.f. Alteration of existing structure = 50% cost of Market Value = $75/s.f Constructio - ion of Addition = 150/s.f CUPERTIN NO Calculate: .• a Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By:Arnold Hom FloodMitigation_2015.doc revised 09101115 Date: 08/02/16 Market Value of Existing Structure = 1000 s.f. x $150/s.f. = $150,000 Improvement Value = 300 s.f. x $150/s.f. + 400 s.f. x $75/s.f. = $75,000 Value Increase (%) = 50% Market Value [Scope is consider Substantial Improvement] SUBSTANTIAL IMPROVEMENT CALCULATOR Area of existing building 1799 Area of existing garage 424 Area of remodel of existing building 1332 Area of remodel of existing garage 0 Area of addition 129 Substantial Improvement? Assuming $150/s.f. (and incl. Garage) Existing structure = (1799+424)$150 =$333,450 Cost of PV Improvement (18 panels) = $18,000 Improvement Value = (129)*$150+1332*$75 + $18,000 = $137,250 % Improvement = 41% PERMIT REQUIREMENTS: If an addition constitutes a substantial improvement to a building, both the addition and the existing building must comply with the effective base flood elevation, foundation, and other flood requirements for new construction. If an addition to a pre -FIRM building does not constitute a substantial improvement, neither the addition nor the existing building must be elevated. If an addition to a post -FIRM building does not constitute a substantial improvement, the addition must be elevated in accordance with current flood requirements. CUPERTINO Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By:Arnold Hom FloodMitigation_2015.doc revised 09101115 Date: 08/02/16