Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15030106-F
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21610 EDWARD WAY CONTRACTOR:THE BUILDING C PERMIT NO: 15030106 OWNER'S NAME: BERRY WILLIAM E AND ODOM TERES 1826 STONE AVE DATE ISSUED:05/20/2015 OWNER'S PHONE: 4087251548 SAN JOSE,CA 95125 PHONE NO:(408)265-7500 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL CONSTRUCT 2ND STORY ADDITION(50 SQ FT); License Class Lie.# REMODEL g72-0/7/Sr. - MASTER BATHROOM(110 SQ FT): REMODEL MASTER Contractor7h.e 1jtl«D/A/G CU- Date �0�� BEDROOM/STUDIO(482 SQ FT),INSTALL(26)LIGHTS 1 hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the (performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$85000 `\�a have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35618014 00 Occupancy Type: permit is issued. 4 1+r APPLICANT CERTIFICATION certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, �j _ / R/ � Date: �� r costs,and expenses which may accrue against said City in consequence of the Issued b /`� � granting of this permit. Additionally,the appy t understands and will comply y' with all non-point source regulations per th pertino Municipal Code,Section 9 18. RE-ROOFS: Signature ,. ° Date 176/W All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. 0 OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,-Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous 1 have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quali Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Munici,. ode,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,a 5534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: 4/ •a• ...,./ Date:5/20/1‹ permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of Califomia. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9 18. Signature Date /56 0/O k CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION ...:.-7.—._i. "& 10300 TORRE AVENUE•CUPERTINO,CA 950143255 ._ ..(408)77.7,322B• FAX (408)777-3333•buildino,a(�cuoertino.oro CUPERTINO ' NEW ADDITION ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT n PROJECT ADD APN ',5J� _/g_ p`(� r Zi to I 0 fiDw� p W owl, R N mg. ' / HONE 01 Od0n� ( ) 19 5-- /5 'f , ,•Tb/• 4/59 STREET ADDRESS ; ` I \ I CITY STATE,ZIP. FAX . • CITY, I IN D 1 CA 40.-01 CONTACT NAME •1.44 AN I.,AI N P5 %_ 6161 EV / -14 41-1 Mlaf- EDI& STREET I g p ? lz 1)° sr. ( CITY,STATE,:ZS A MO „ p ! el& FAX ,/OWNER -'`•44�1'NMI-BtTII-DER.' ` ❑ OWNER AGENT. 0 CONTRACTOR - 0 CONTRACTOR AGENT 'Li..ARCHITECT _ 0 ENGINEER.,.;,0-DEVELOPER:- 0 TENANT CONTRACTOR NAME t LICENSE NUMBER— LICENSE TYPE BUS.LIC 4 L +6u tint t,46 .COIMP,w f q .. 2 2, 7 -� COMPANY NAMEE-1 TAIL FAX cw i 7.03 I/4 . 4 • S • VLA IC I GG(Q-rk►g.311l1.0/44 CoMPA1► W,op STREET ADDRESS CITY, ATE PHO 3z,o �cAzF �,izi�r� eT C' �'� - G�. as 1 ZS yah ��Sd ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC 4 _ 'RV PvI ) LO(4 '' )12 COMPANY I&CL.A\ST'RtilcT g/VL E E NFo 0 IZCLL5t.COh. .-MAIL FAx STREET ADDRESS �aM t kg) D �. 51.J) CITY,STATE,71P p�D�,7 PHONE S Z o L . --- 1-�- r..rp-evaut-- e I DESCRIPTION OF WORK / Q rel / 6,- YYlas+e r .1z-ed Y�) br,-kli. ra , heckrap h..- ' 1 2 . >4Q1�1-a-e.., c 60 s3 ...._ Ouktf o•-- - i f a.0 Clrnt'a_ koe s� L.4/- _. b • .. . . . - ;J . .... _ . . ... ...... ... _... . .. .. ..- . - EXISTING USE PROPOSED USE CONSTR TYPE g STO S ADD, USE TYPE OCC. 1 SQ.FT. VALUATION(5) EXISTG , NEW FLOOR DEMO TOTAL AREA 21 3t; AREA 5.--t) AREA�c� NET AREA S D PG i. t 6 g31 `�."7 , BATHROOM vJ KITCHEN /// v J OTHER"IOTA t-• !�_/ �/ / J(� REMODEL AREA REMODEL AREA � ( / REMODEL AREA ss-- MG E2,� . v3 to, 5 - PORC}AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: D DETACH V7 / _ P /A ❑ATTACH DWELLING UNITS: /�+ ISA SECOND UNIT 0 YES SECOND STORY ❑YES BEING ADDED? ONO ADDITION? ONO • PRE-APPLICATION ❑1 ES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES s,REGEI 7',e t a�,�. tti,V E z'; TOTAL}:AI,UA;ION; PLANNINGAPPL4 0 N PLANN'.GAPPROVAL LETTER EICHLERHOME? ❑?NO }--,_„"a =4 .z fit{. _ ' ���� BQ /�1 By my signature below,I certify to each of the following: I am the property owner or authorized agent Co act on the property owner's behalf. I have read this application and the information I have pr vided' have read the Description of Work and verify it is accurate. I agree to comely with all applicable local ordinances and state laws relating to b '�di co l authorize representatives of Cupertino to enter the above-identif d prope - for inspection purposes. Sig�lature ofApplicanUAgent: '�'V .A u Date: -3^ i SUPPLEMENTAL INFORMATION REQ 4 D . �, =pian cHECIC YP-Ei_s "I, — u, `<= _ov_04 sLIP, 0,u.. t_ New SFD or Multifamily.dwellings: Apply for demolition permit for -�t ins s . - l g`„0,�OYE:R,TI COUR�'ER e BL-II,DarYL RE47E4Y a E existing building(s). Demolition permit is required prior to issuance of building :4,- �, -M # .4-M •T� . permit for new building. E,❑�BXPRESS -- %_t7,84144.vs-AOU ;P+AN��G PLAI\REVLE1s r f _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure �sT 'D-r,Rn r a. �J j 17Bircwo7txs r� ;s;: form if any Hazardous Materials are being used as part of this project. .� sr j 1 ' ,a' }§ s 1 x t ";r ley -LARGEg,I r is a V 4,, EDE_Ovsi''t� - i �c •ry+ Copy of Planning Approval Letter or Meeting with.Planning prior to x Y t 't1' �� r'`` iii A r< submittal of Building Permit application. ❑ 24AJOR . w-t -rr---,--— �lsTi tI: a= ,Itt ,r IM.,-Uv s>;.t ldirti l ut a ,_ �EIvdiRONNIEISTAL HEAL:rnt- . r� " BldgApp 2011.doc revised 06/21/11 . /, ' —' v(C/SCS ' /' CONSTRUCTION PERMIT APPLICATION - 4 i� Ys COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION '_' ,y,3...,ik Jy`fr.' 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 ''� (408)77.7,3228. FAX (408)777-3333 • buiIdina a(�cuoertino.oro CUPERTINO ❑NEW CONSTRUCTION . -]ADDITION BIALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDREss�� \( APN 5 � - /r�- j ,C I(o/(� . f�DwA�D W C// OWINIrR N Mg . HONE - oraM ( ) 1 5-V 15 'tz W7 '/ 7/1� STREET ADDRESS I CITY STATE,ZiP. F. CAA rr/r7--r l N.13 ., C G 1 COI FF L{ CONTACT NAME 14Vy GIf-m`V NA(N1X., 400Zl6- VIS/ E-Vfrow M t41-1 miw.co, STREET.4D1ES f s 8 r yo TScr -co. . ` CITY,STATE, ZIP, A y__ - �` r(� �+I Ip Ti TU FAX c WNER' OdvER-BUILDER'. 0 OWNER AGENT 0 CONTRACTOR 0 CONTRACTOR AGENT ❑ ARCHITECT 0 ENGINEER. -,❑ DEVELOPER ❑ TENANT --- CONTRACTOR q NAME LICENSE MBE LICENSE TYPE BUS.LIC 4 tel,,- gLit,-�iI,,4.6 cow0&0`'l 2S 2-2- 7 (3-t ��/� COMPANY NAME E-MAIL � FAX 4vo per' '7 g._3 �vl . , S�' E v IC l tae 6 -rti�13u1r.®1 v& core Mit f,o p 6 STREET ADDRESS CITY, ATE PHO z,o Icx t rele,r� r,j -G Gli- / �-rosIC. Ct. ci) 2-c yo. D <-7S�sd ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS,LIC 4' `R.YWiv }A)4 L ,%. j 72. COMPANY NAME E-MAIL KCL. 5 TL ut' PAL- / NFo & ,�.�ct-st .CD/ Fax STREET ADDRESS 1M CA.1 t tib RE, . f, CITY,STATE,ZIP PHONE t--1,p-ev.ac_,t--- C-A 9'(/0?-7 DESCRIPTION OF WORK �D.-44.6 1 of In5t64•e r 1•edroo�[r+� b , a•4I�r0a ,, be' oo►—. 2 1 • 1 tel-- . lie r. 'F' LAO '`-+' 6i c'Tier'll1'Q OCCSo� .I k1 'E-(.12,CCC: t f r►Z,tS1. 5. EXISTING USE PROPOSED USE I CONSTR.TYPE TO•I S �pp .1. USE TYPE OCC. SQ.FT. VALUATION(5) EXISTG NEW FLOOR DEMO TOTAL v — - - - -- AREA t ti 36- AREA.5.-10 AREA. i_c- NET AREA S D Pt t/6 /Z 5i BATHROOM �J KITCHEN (/b 7—Q j?.r•4 . J(i` {/ / REMODEL AREA REMODEL AREA w,...//4),... REMODEL AREA r7 H S iMG�!� , 2 , 5 5 . PORC. AREA DECK AREA TOTAL DECK/PORCH\ AREA I GARAGE AREA:L ■DETACH VIS/7 PH j\f/A1 ❑ATTACH DWELLING UNITS: ISA SECOND UNIT ❑YES SECOND STORY ❑YES - ' BEING ADDED? ONO ADDITION? ONO PRE-APPLICATION ❑l ES LF YES,PROVIDE COPY OF I IS THE BLDG AN ❑YES OEI I $y s 'x i�`r ;t ki '�, :. TOTAI.•}Ir'AI.TJ D PLANNING ADPL= ONO PLANNING APPROVAL LETTER I EICHLER HOME? NO 'APA.,-.,,44;,:‘ i} (�J��JJ. . /-,) By my signature below,I certify to each of the following.: I am the property owner or authorized agent to act on the property owner's behalf. I haw-read this application and the information I have pr vided' . have read the Description of Work and verify it is accurate. I agree to compIy with all;applicable local ordinances and state laws relating to/ b 'di co 1,cti-... 'authorize representatives of Cupertino to enter the above-identif d prope for inspection purposes. Signature of Applicant/Agent: T '4 u Date: -4- C / / . SUPPLEMENTAL INFORMATION REQ -TD vfa PLAT\CHECICTIPEy;t: ?kt r Y G IP - ' ' oc� _cs's1,-IP r New SFD or ;T , r."`l �-` ;.', S � "Aw�.'"?31� +i�4ryt Fcr i Multifamily dwellings: for demolition permit for � �� � � ., I•� OYER TH) COUM1TER 4 r'`gutED r PL.gREvlE i existing building(s). Demolition permit is required prior to issuance of building 4 x � t• q ; permit for rev,building' VD EAPEss�'0 :tt '• e EV 4 r Commercial Bldgs: Provide a completed Hazardous Materials Disclosure r � `C _ ` — P S0-i zo i "I *,itt f.�,�p t® ,v,-I I ��iORICS*T t{ .-�,�- form if any Hazardous Materials are being used as part of this project. -. �.�.;.; �'�"j,���}�-�,�s;, �.�'����"t��- �l�r�, '-.r '.LI LAZ2 E t s 04 F atiP L _Copy of Planning Approval Letter or Meeting with Planning prior to 4I s "� ' , r i `' submittal of Building Permit application. — pb-' Rt 014#� p .i—/. rnRY En ERDISTRIC� g{ gi)thgtx P..r... :110.,..,.,e- �v 1 T N,'.-- 1•,11fE1tTAL.HE:4I TA_ ._. BldgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO / FEE ESTIMATOR-BUILDING DIVISION ...619 ADDRESS: 21610 Edward Way DATE: 05/11/2015 REVIEWED BY: Sean i'l,:,. APN: BPM /1�D3o/U6 "VALUATION: $85,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition USE:POTC RIMARY SFD or Duplex Unit? 0 Yes 0 No PENTAMATION 0 Yes QNo PERMIT TYPE: 1 R3SFDADD WORK CONSTRUCT 2ND STORY ADDITION (50 SQ FT); REMODEL MASTER BATHROOM (110 SQ FT): SCOPE REMODEL MASTER BEDROOM/STUDIO (482 SQ FT), INSTALL (26) LIGHTS AND.((7) OUTLETS ei OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID CONSTR. (s.f.) R-3 (Custom) 1 II-B,111-B,IV,V-B 50 $1,091.00 IADDPLCK $1,057.00 IADDINSP TOTALS: 50 $1,091 00 , $1,057.00 �,.i �' �h4Mr a y� r + 4 S Y t 1 Ivrr�,: 7 '1 r ' t Y P t 4i ', x h r r r&] rl- r it ?t F ,'MECH, IOU +L Y. a0 Yes °;�• ��PT:LT ;B,HOURI,,Y; 0'1'es'` Q z Noy ,y"ELEC, O'U�iLY' �Q Yes ` <<n,,�. ,� ,� , ©,No> M � + ?,I� � P QNo t,fei-n /'Irw(i,c rk I I ."iarml,_,.Plan Ci.c,::k 1 I Elec.Plan Check 1.22_1 hrs $0.00 .1/,xii Pc,,nia 1-ec': Plumb Po.Ina i'Vc:: Elec.Permit Fee: IEPERMIT girl„r ;.t,;,1,. 1:1,r,. 1--1 Orh,:r PIu,2rh 1;,v) Other Elec.Insp. 0.0 hrs $48.00 Alec lr. A7,1, lee Plumb Inca rte ON: 1,r::1>.Feo NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Efl' 7.1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $1,091.00 I 1.10 I s.f. Remodel,Bath(<=300 sf) Suppl.PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 $645.00 1REMRESBAT PME Plan Check: $0.00 I 482 I s.f. Remodel,Other Permit Fee: $1,057.00 $503.00 1REMRESOTH Suppl. Insp. Fee:® Reg. 0 OT 0.0 hrs $0.00 33 Electrical PME Unit Fee: , $0.00 $113.00 IBREMRECEP Recep/Switch/Outlets PME Permit Fee: $48.00 Construction Tux: ,9clmirri.stratire Fee: 0 Work Without Permit? 0 Yes 0 No $0.00 0 Advanced Planning Fee: IPLLONGR $7.00 Select a Non-Residential 0 Travel Documentation Fee: ITRAVDOC $48.00 Building or Structure 0 i Strong Motion Fee: IBSEISMICR $11.05 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $4.00 V SUBTOTALSa $2,266.05 $1,261.00 'TOTAL FEE _ $3,527.05 Revised: 04/01/2015 • CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION lkADDRESS: 21610 Edward Way DATE: 05/11/2015 REVIEWED BY: Sean 1•4',ty. APN: BP#: 450 eylQ6:2 *VALUATION: $85,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: - Addition PRIMARY 2nd Unit? 0 Yes 0 No PENTAMATION USE: SFD or Duplex OTC? Oyes No PERMIT TYPE: 1R3SFDADD WORK CONSTRUCT 2ND STORY ADDITION (50 SQ FT); REMODEL MASTER BATHROOM (110 SQ FT): SCOPE REMODEL MASTER BEDROOM/STUDIO(482 SQ FT), INSTALL (26) LIGHTS AND ((7)OUTLETS OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID CONSTR. (s.f.) R-3(Custom) 1 II-B,III-B,IV,V-B 50 $1,091.00 IADDPLCK $1,057.00 IADDINSP TOTALS: 50 $1,091.00 _ $1,057.00 MECH,HOURLY- ' 0 Yes .No' ;PLUMB,HOURLY Q Yes .O No• "ELEC,'HOURLY Mech.PlanCheckY I I Plumb.Plan Check I I Elec.Plan Check 0.0 hrs $0.00 .Mech. Permit Fee: Plumb. Permit Fee: Elec.Permit Fee: IEPERMIT Other Mech.Insp. I Other Plumb Insp. n Other Elec.Insp. 0.0 hrs $48.00 Mech, hasp. Fee: Plumb.Insp. Fee: Elec.Insp.Fee: NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eft'. 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $1,091.00 1.10 s.f. Remodel,Bath(<=300 sf) Suppl.PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 $645.00 IREMRESBAT PME Plan Check: $0.00 482 s.f. Remodel,Other Permit Fee: $1,057.00 $503.00 IREMRESOTH Suppl. Insp.Fees Reg. 0 OT 0,0 hrs $0.00 33 Electrical PME Unit Fee: $0.00 $113.00 IBREMRECEP Recep/Switch/Outlets PME Permit Fee: $48.00 Construction Tax: I Administr-cxtine Fee: O Work Without Permit? 0 Yes ® No $0.00 Advanced.Planning Fee: 1PLLONGR $7.00 Select a Non-Residential O Travel Documentation Fee: ITRAVDOC $48.00 Building or Structure O Strong Motion Fee: 1BSEISMICR $11.05 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $4.00 SUBTOTALS: I $2,266.05 $1,261.00 - TOTAL FEE: I $3,527.05 • Revised: 04/01/2015 CITY OF CUPERTINO \...riz.,4,„f, FEE ESTIMATOR-BUILDING DIVISION "' ADDRESS: 21610 Edward Way DATE: 03/17/2015 REVIEWED BY: Sean x'4.1°Sd APN: BP#: /5O(%)%1O *VALUATION: $85,00Q. *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY 2nd Unit? 0 Yes 0 No ' PENTAMATI I ' USE: SFD or Duplex 1 R3SFDADD OTC? Yes No PERMIT T E: WORK Construct one sto addition 50 s• ft • Interior Remodel 285 s. ft . moi,/ /,?y 4,. SCOPE TYPE OF FLR AREA ��- OCCUPANCY TYPE: CONSTR. (s.f.) PC FEES /"'FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,111-B,IV,V-B 50 $1,091 0 1ADDPLCK $1,057.00 1ADDINSP / TOTA,;S: 50/ $1,091.00 _ $1,057.00 MECH,HOURLY . ...0 Yes_ N'. P p, B;H I tRLY Ye`' No`` ELEC,HiOURLY 0 Yes No b-kch. Plan Check I web.PI„ r !heck Mir' Lice..P/an Che ch :llech. Permit Fee: 1 Plumb.Pt F.e Flee. Permit Fee: Other Mech. /rasp. I I Othe 'Plumb Insp. , Oilier Elec.Insp. F- Mech.Insp. 1^'ee: l tmb. lusp.Fee: Flee_Insp.Fee: NOTE:This estimate does not include fees d e to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the p•eliminary in tion available and are only an estimate. Contact the Dept for addn'1 info. FEE ITEMS (Fee Resolution 11-053/f. 7/1/1 ) QTY/FEE MISC ITEMS (1) E Plan Check Fee: / e 1,091.00 1285 s.f. Remodel,Other Suppl. PC Fee: 0 Reg. ® O,” 0,0hrs $0.00 $431.00 IREMRESOTH A PME Plan Check: $0.00 Permit Fee: $1,057.00 Suppl.Insp.Fees Reg. ,* OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction?'m: Administrative Fe : 0 Work Without P-rmit? ® Yes 0 No $0.00 0 Advanced Planning Fee: IPLLONGR $7.00 Select a Non-Residential 0 Travel Documentation Fees: Building or Structure Strong Motion Fee: IBSEISMICR $11.05 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $4.00 ~•SUBTOTALS:' $2,170.05 $431.00 . “, TOTAL'FEEi' $2,601.05 Revised: 02/14/2015 CALGREEN RESIDENTIAL CHECKLIST- MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPERTINO ALBERT SALVADOR, PE,GEO.,BUILDING OFFICIAL MAY 20 2015 . . 10300 TORRE AVENUE•CUPERTINO,.CA 95014-3255 I, • (408)777-3228•FAX(408)777-3333•buildinqacuaertino.orq PURPOSE The 2013 CalGreeh Code applies to additions or alterations of existing residential buildings where the addition or alteration increases the building's Conditioned area,volume, or size and also applies to all new tow-rise residential buildings, high-rise residential buildings,or both_ Existing site and landscaping improvements that• - are not otherwise disturbed are not subject to the requirements of CALGreen. .Project Name errti Od0.111 Project Address: _ rt _-rtiyio A , Project Description'. -W111104 :Fecorici cg-fort4 ahal rryttyletg 1 Instructions: - I-. 'The Owner or the Owner's agent shall employ a licensed professional experienced with the California . - • Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project_ 2: The licensed professional,in collaboration with the owner and the design professional shall initial Column 2 of this checklitt, sign and date Section 1 -Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the ia epartrnentrgi Mrel.. 7• r• -;,--sional shall complete Column 3 and sign and date Section Z Eg; ntation VseuhtlidMfaiming Deportment 14Pind of this checklist and submit the completed form to the Buitdinf•= or. IMAY:2 02015 REVIEWED FOR CODE COMP'. ,Ikultjh Column 2 Column 3 • " MANDATORY FEATUIRIIKORMWASOEw /1-Are.,,/ ' Project ' Verification Re.uirements . A4.1 PLANNING AND DESIGN Planning and Design-Site Development 41062 Storm water drainage and retention during construction. A plan is developed and implemented to manage storm water drainage during 11 0 construction. 4.1063 Grading and paving. The site shall be planned and developed to keep surface water away from buildings_Construction plans shall indicate how U 0 site grading or a drainage system will manage all surface water flows. OFFICE COPY Page 1 of 5 - CalGreen 2014.doc revised 11/04/14 A4.2 ENERGY EFFICIENCY General _ 4.201.1 Low-rise residential buildings shall meet or exceed the minimum= . : standard designrequired by the California.Energy Standards. ' Q. A4.3 WATER EFFICIENCY AND CONSERVATION Indoor Water Use - - :- 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals)and fittings(faucets and showerheads)shall comply with the following: 4303.1:3:2 Water Closets.The effect-tie flush volume ofall water closets shall riot exceed 1:28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the ELS.EPA.WaterSense - Specifications for Tank=type Toilets. • • El 4.303.1:3:2 Urinals: The effective flush volume of urinals shall not exceed 0.5 gallons per:flush. 1 El.4303.1:3.1 Single Showerheads. Showerheads shalt have a maximum flow rate of:not More than 2.0:gallons per minute at 80 psi. Showerheads shall be certifiedto the performance criteria of the U.S. EPA WaterSense Specification for showerheads. .: 4.303.1.3:2 Multiple Showerheads serving one shower_-When a shower is served by:more than one showerhead,the combined flow rate of - - - alt showerheads and/or other Shower outlets controlled by a single valve shall pot exceed2:0 gallons per minute at 80 psi,or the showershall be .eS1 • : designed to allow only one shower outlet to be in operation at a time. •- 4:303:1.4.1 Residential lavatory faucets. The maximum flow rate of : residential lavatory faucets shaftnot exceed 1.5 gallons per minute at 60 , psi. The minimum flow rate of residential lavatory faucets shall not be less - . - than 0.8gallons per minute at 20 psi. 4 303:1.3.2.Lavatory faucets in common:and public use areas. The maximum flow rate of lavatory faucets installed in common and public:use areas(outside of dwellings or sleeping units)in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. • El 4:303x.4.3 Metering.faucets..Metering faucets when installed in residential buildings shalt not deliver more than 025 gallons=per cycle. . Q 4:303.1:4:4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8gallons.per Minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate but not to exceed -22 gallons per minute at 60 psi,and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. - -4.303.2 Standards for plumbing fixtures and fittings:.Plumbing fixtures and fittings shall be installed in accordance with the California.Plumbing Code, r� : and:shall meet the applicable standards referenced in Table 1401.1 of the LJ California Plumbing Code. Page.i of 5. - . . C a1Gre _ f4.doc en 20 revised II/04l14 - Outdoor Water Use = . 4:304:1 Irrigation controllers, Automatic irrigation systems installed at the time of final inspection shall be weather-based. 4.304.1.1 Controllers shall be weather-=or soil moisture-based controllers that automatically adjust irrigation in response to changes in plants`needs as weather conditions.change:: Q 4:304:1.2 Weather-based controllers without integral rain sensors or communication systems that account forlocal:rainfall shall have a separate, wired or wireless rain senior Which connects or communicated with the controiler(s): Soil moisture-based controllers are not required to have rain sensor input. . A4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY Enhanced Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes;electric,cable& conduits,or other openings in plates at exterior walls shall be protected against>the passage of rodents by closing such openings with cement mortar,. j concrete masonry or similar method acceptable to the enforcing agency. -Construction Waste Reduction,Disposal and Recycling 4408.2 Constructionwaste management plan. Where a local jurisdiction • I does not have a construction and demolition waste management ordinance,a construction Waste management plan shall be submitted for approval to the enforcing agency. Building Mainteenance.and Operation :4.410.1 Operation and maintenance manual. At the time offinal inspection, an operation and maintenance manual shall be provided to the building Q. occupant or owner_ A4.5 ENVIRONMENTAL QUALITY Fireplaces.- 4.503.1 General:-Install only a direct-vent sealed-combustion gas or sealed : U 0 wood-burning fireplace,.or.a sealed woodsteve. Pollutant Control 4:504.1 Covering of duct openings-and protection of mechanical - equipment during construction.. Duct openings and other related air 0 distribution component openings shall be covered during construction. 4.504.2:1.Adhesives,sealants and caulks. Adhesives,sealants and caulks = shall be compliant with VOC andother toxic compound:limits. 4.504.22 Paints and-coatings Paints,::stains and other coatings shall be j compliantwith VOC limits. 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings shall be compliant with product weighted MIR limits for ROC and other toxic Q compounds:-. . Page 3 of 5 CalGreen 2014:doe revised 11/04/14 • . . 4.504.24 Verification. Documentation shall be provided to verify thatEl compliant VOC limit finish materials-have been used. -- 4.504.3 Carpet Systems. Carpet and carpetsystems:shalt be compliant with )A VOC limns. i Q 4:504.4 Resilient flooring systems. Eighty(80)percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools(CHPS)Low-emittting Q I Materials List or be certified under the Resilient Floor Covering Institute(RCFI) FfoorScore program.. 4.504.5 Composite wood.products. Particleboard, medium density fiberboard(MDF);and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. Interior Moisture Control . . 4.505.2 Concrete slab foundation. Required vapor retarders and capillary _ breaks are also required to comply with.CaiGreen Section.4.5052.1. 13 4:505:3 fill'oisture content of building materials. Moisture content of building materials used in wail and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate.outside the building are provided in every bathroom. Environmental Comfort 4.507.2.Duct systems are sized-and designed and equipment is selected : _ using:the.following.Methods: . 1: Establish heat foss and heat gain values according to ACCA Manual J or equivalent. ►_i J. 2. Size duct systems according to ACCA 29-D(Manual D)or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S(Manual S) - or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS Qualifications 702.1 Installer training. HVAG system installers are trained and certified in o o the proper installation of HVAC systems.. 702.2 Special inspection. The Licensed Professional responsible to verify. CALGreen.compliance is qualified and able todemonstrate competence in the discipline they-inspect and.verify.: Verifications : 703.1 Documentation::Verification of compliance witl?CAiGreenmay include construction documents,plans;specifications, builder or installer. certification.inspection reports,or other methods accetabfe to the enforcing a agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior fo final inspection approval Page 4 of 5 CalGreen_Z014.doc revised 11104114 CALGREEN SIGNATURE DECLARATIONS Project Name: r r - Odom Project Address: .d bf l' dwctrd a( Eli r:+,lar,, C Project Description: 1J ,,c-j-p) 1t,e o Ft, .9 SECTION 1 — DESIGN VERIFICATION Complete all lines of Section 1.—"Design Verification"and submit the completed checklist(Columns 1 and 2)with the plans and building permit application to the Building Department The owner and design professional respo ible for-compliance with CaiGreen Standards have revised the plans and certify that the items checked above are ,ereby incorporated into the project plans and will be implemented into the project in acco i-' _- with the:requirem:nts-set forth in.the 2013 California Green Building Standards Code as :adop y 4 ( o upertino:: 67/1-3/15.--* Owne s.Signature a/_ \ Date °wigName tease Print) � . 5--(3_1 Design o ssionaars Signature Date frie4ati /VI liter- Design Yrofessionars iter- Design_Professional`s Name (Please Print) Signature of License Processional responsible for CaiGreen compliance - Date Name of License Professional responsible for CaiGreen compliance(Please Print) Phone Email Address,for License Professional responsible for CaiGreen compliance SECTION 2—IMPLEMENTATION VERIFICATION .Complete,sign and submit the competed checklist,including-column.3,.together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection-. I have inspectedthework and have received sufficientdocumentation to verify and certify that the project identified above was constructed in accordan e with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Buildint tandards Code as adopted by the City of Cupertino. -L1Z/d' 570//e Signature of License Prof/ional responsible for CalGreen compliance Date : ,m/c 46G 4 672-6i-i412- . . dog.27<ede Name of:License Professional responsible for CalGreen compliance(Please Print) - Phone /Cilie G 0 e,i3 /GO/4J eomp.w . .06:6- Email A dress for License-Professi nal responsible for compliante I _ Page 5 of 5 : CalGreen 2014.doc revised 11/04/14 BUILDING ENERGY ANALYSIS REPORT PROJECT: RECETVEn Berry Residence MAR 4 7 HIS 21610 Edward Way yrs Cupertino, CA 95014 Project Designer: Megan Miner Design 1750 De Marietta Ct. #4 San Jose, CA 95126 "A 408-396-0951 4t re ,. CUPERTINIO Report Prepared svila i oe a • aV'/.:� 3 P rtment Josh Minerr :, = `' MAY 2015 J.M Title 24 Services �.`.tVIEVVED VOK ( ODE COMPLIANCE 4353 Hyland A San Jose, CA 95127 Kevlevrea by. 4083946882 Job Number: 1502 Date: 1/12/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft,LLC—www.energysoft.com. EnergyPro 6.3 by EnergySoft User Number. 7674 ID:1502 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1R Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 11 Form MF-1R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 15 EnergyPro 6.3 by EnergySoft Job Number. ID:1502 User Number.7674 CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name:Residential Building Calculation Date/Time:03:24,Mon,Jan 12,2015 Page 1 e18 Calculation Description:Title 24 Analysis Input File Name:1502 Berry Rosidence.xml GENERAL INFORMATION 01 Project Name P Residential Building 02 Calculation Description Title 24 Analysis 03 .ProjectLocalion 21610 Edward Way 04 CA City Cupertino 05 Standards Version Compliance 2014 06 Zip code! 95014 07 Compliance Manager Version BEMCmpMgr 2013-3(651) 08 Climate Zone CZ4 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation(deglCardlnal) 0 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units ;1 14 Total Cond.Floor Area(FT2) 2513 15 Number of Zones 2 16 Slab Area(FT2) 0 17 Number of Stories 3 18 Addition Cond.Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area(FT2) 0 21 Glazing Percentage(%) 12.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a ccertifieded HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use(kTDVlft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 35.52 35.05 0.47 1.3% Space Cooling 20.19 20.62 -0.43 -2.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 14.06 14.06 0.00 0.0% Photovoltaic Offset — 0.00 0.00 — TOTAL 69.77 69.73 0.04 0.1% s ReKistration Number: 215-A0014516A-000000000-0000 Registration Date/Time: 2015-01-1203:50:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-12122014-651 Report Generated at2015-01-12 03:26:22 CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE,METHOD CF1R-PRF-01 Project Name:Residential Building Calculation Date/Time:03:24,Mon,Jan 12,2015 Page 2 of 8 Calculation Description:Title 24 Analysis Input File Name:1502 Berry Residence.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cathedral Ceiling • No cooling system included PROJECT HERS FEATURES The following are project-level features that must be fold-verified as a condition for meeting the modeled energy performance for this computer analysis. These,,plus any additional HERS features listed in the building components tables below,requre field verification by a certified HERS Rater. Building-level Verifications: • High Quality Insulation Installation(QII) Cooling System Verifications: • —None— HVAC Distribution System Verifications: • —None— Domestic Hot Water System Verifications: • —None-- ENERGY DESIGN RATING This is the sum olthe annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building(Energy Budget)and the annual TDV energy consumption for lighting and components not regulated by Title 24.Part 6(such as domestic appliances and consumer electronics)and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy(kTDV(f2)' 115.56 115.52 0.04 0.0% •includes calculated Appliances and Miscellaneous Energy Use(AMEU) BUILDING FEATURE INFORMATION 01 02 03 .04 05 06 07 Number of Dwelling Number of Number of Water Project Name Conditioned Floor Area(sft)' Units Number of Bedrooms Number of Zones Ventilation Cooling Systems Heating Systems Residential Building 2513 1 6 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Floor Area Avg.Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 1st Floor Conditioned HVAC Systeml 1473 8 DHW Sys 1 2nd Floor Conditioned HVAC Systeml 1040 B DHW Sys 1 Registration Number: 215-A0014516A-000000000-0000 Registration Date/Time: 2015-01-12 03:50:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-12122014-651 'Report Generated at 2015-01-12 03:26:22 CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name:Residential Building Calculation Date/Time:0324,Mon,Jan 12.2015 Page 3 of 8 Calculation Description:Title 24 Analysis Input File Name:1502 Berry Residence.xml OPAQUE SURFACES 01 02 03' 04 05 06 07 08 09 4 10 Verified Window and Door Tilt(deg Existing Name Zone Construction Azimuth Orientation Gross Area(ft2) Area(ft2) ) Status Condition 1 Front Wall 1st Floor R-0 Wall 0 Front 288.6 56 90 Existing No Left.Wall 1st Floor R-0 Wall 90 Left 198 12 90 Existing No Rear Wall 1st Floor R-0 Walt 180 Back 430 112.6 90 Existing No Right Wall 1st Floor R-0 Wall 270 'Rig'hl 278.6 90 Existing No Roof 2 V 1st Floor R-19 Roof Attic 567.6 Existing No Raised Floor 1st Floor R-0 Floor Crawlspace 1473 Existing No , t Front Waif 2 2nd Moor R-0 Wall 0 Front 132.6 10 90 Existing No Loft Wall 2 2nd Floor R-0 Wall 90 Left 216.6 90 Existing No Rear Wall 2 2nd Floor R-0 Wall r 180 Back 292.6 46.6 90 Existing No Right Wall 2 2nd Floor R-0 Wall 1 270 Right 216.6 90 Existing No Front Wall 3 2nd Floor R-13 Wail 0 Front 160 56 90 New N/A Loft Wall 3 2nd Floor R-13 Wall 90 Left 40 90 New. N/A Right Wall 3 2nd Floor R-13 Wall 270 Right 40 90 ,New • N/A Roof 3 2nd,Floor R-19 Roof Attic 990 Existing No ' Roof 4 2nd Floor R-30 Roof Attic 38 New N/A Raised Floor 2 2nd Floor R-0 Floor Crawlspace , 84.6 Existing No. Front Wail 4 Garage Garage Ext Wall 0 Front 160 90 Existing No Left Wall 4 Garage Garage Ext Wall 90 Left 168 90 Existing No Right Wall 4 Garage Garage Ext Wall 270 Right 88 90 Existing No. Interior Surface 2 Garage>>1st Floor R-0 Walll 240 Existing No Roof 5 Garage R-19 Roof•Altic 421 Existing No I OPAQUE SURFACES—Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 13 ' Roof Roof Framin Verified Orientatio Area Skylight Roof Rise Roof Roof Reflectan Emmittan g State Existing Name Zone Type n (ft2) Area(ff2) (x in 12) Pitch Tilt(deg) ce ce Factor s Condifion Roof 2nd Floor R-30 Roof Atticl -specify- ' 12.1 6 4 0.33 18.43 0.1 0.85 0.07 New N/A 0 Registration Number: 215-A00.14515A-000000000-0000 Registration Date/Time: 2015-01-12 03:50;46 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-12122014-651 Report Generated at 2015-01-12 03:26:22 ' CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residential Building Calculation Date/Time:03:24,Mon,Jan 12,2015 Page 4 of 8 Calculation Description:Title 24 Analysis Input File Name:1502 Berry Residence.xml ATTIC ' 01 02 03 04 05 06 09 10 11 Verified Roof Roof Radiant Existing Name Construction Roof Rise Reflectance Emittance Barrier Cool Roof Status Condifion Attic Attic Roof Cons 4 0.1 0.85 No No Existing No. ' WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Verified Width(ft Height ;Multiplie Existing Name Side of Building ) (ft) r Area(ft) U-factor SHGC Exterior Shading Status Condition Window Front Wall - - 1 24.0 0.55 0.67 Insect Screen(default) Existing • No Window 2 Front Wall - - 1 32.0 0.55 0.67 Insect Screen(default) Existing No Window 3 Left Wall - -- 1 12.0 0.55 0.67 insect Screen(default) Existing No Door Rear Wall - - 1 53.3 0.53 0.65 Insect Screen(default) Existing No Window 4 Rear'Wall -- - 1 21.0 0.55 0.67 Insect Screen(default) Existing No ' Window 5 Rear Wall - - 1 8.5 0.55 0.67 Insect Screen(default) Existing No Window 6 Rear Wall - - 1 8.5 0.55 0.67. Insect Screen(default) Existing No Window 7 Rear Wall -- ' - 1 21.3 0.55 0.67 Insect Screen(default) Existing No Window 8 Front Wall 2 -- - 1 10.0 0.40 0.40 Insect Screen.(default) , New N/A Window 9 Rear Wall 2 - - 1 18.0 0.55 0.67 Insect Screen(default) Existing No Window 10 Rear Wall 2 - - 1 18.0 0.55 0.67 Insect Screen(default) , Existing No Window 11 Rear Wall 2 - - 1 6.0 0.55 0.67 Insect Screen(default) I Existing No, Window 12 Rear Wali 2 - - 1 4.6 0.40 0.40 Insect Screen,(default) New N/A Window 13 Front Wa113 - - 1 28.0 0.40 0.40 Insect Screen(default) New N/A Window 14 Front Wall 3 - - 1 28.0 0.40 0.40 Insect Screen(default) New N/A Skylight Roof 1 6.0 0.40 0.40 New 'N/A Skylight 2 Roof 1 6.0 0.40. 0.40 New N/A DOORS 01 02 • 03 04 05 06 Name Side of Building Area(ft2) U-factor Status Verified Existing Condition Door 2 Front Wall 33.3 0.50 Existing No • Registration Number: 215-A0014516A-000000000-0000 Registration Date/Time: 2015-01-12 03:50:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards-2013 Residential Compliance 'Report Version-CF1R-12122014-651 Report Generated at 2015-01-12 03:26:22 CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residential Building Calculation Date/Time:03:24,Mon,Jan 12,2015 Page 5 of 8 Calculation Description:Title 24 Analysis Input File Name: 1502 Berry Residence.xml, OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 Construction Name Surface Type Framing Total Cavity R-value Assembly Layers 2x4 Top Chord of Roof • Cavity/Frame:no insuL/2x4 Top ChM Attic Roof Cons 'Attic Roofs Truss @ 24 in.Q.C. -no insulation- • Roof Deck:Wood Siding/sheathing/decking • Roofing:Light Roof(Asphalt Shingle) • Inside Finish:Gypsum Board R-0 Wall Exterior Walls 2x4 @ 16 in.O.C. -no insulation,(vertical)- • Cavity/Frame:no insul./2x4 • Exterior Finish:Wood Siding/sheathingldecking • inside Finish:Gypsum Board R-1 9 Roof Attic Ceilings(below attic) 2x4 @ 24 ih,O.C. R 19 • Cavity/Frame:R-9.1/2x4 • Over Floor Joists:R-9.9 insuL • Inside Finish:Gypsum Board R-0 Weill Interior Walls 2x4 @ 16 in.O.C. -no insulation(vertical)- • .Cavity/Frame:no/nsul./2x4 • Other Side Finish:Gypsum Board • Floor Surface:Carpeted R-0 Floor Crawlspace Floors Over Crawlspace 2x12©16 in.O.C. -no insulation- • Floor Deck Wood Siding/sheathing/decking • Cavity/Frame:no insul./2x92 • Inside Finish:Gypsum Board R-13 Wall Exterior Walls, 2x4 @ 16 in.O.C. R 13 • Cavity/Frame:R-13/2x4 • Exterior Finish:Wood SIding/sheathing/decking • Inside Finish:Gypsum Board R-30 Roof Attic Ceilings(below attic) 2x4 @'24 in.O.C. R 30 • Cavity/Frame:R-9-9/2x4 • Over Floor Joists:R-20.9 insul. • Inside Finish:Gypsum Board • R-30 Root Atticl Cathedral Ceilings '2x4©24 in.O.C. R 30 Cavity/Frame:R-301 2x4 • Roof Deck:Wood Siding/sheathing/decking • Roofing:Light Roof(Asphalt Shingle) • Floor Surface:Carpeted • R-0 Floor. No Crawlspace Interior Floors 2x12©16 in.O.C. -no insulation Floor Deck:Wood Siding/sheathing/decking • Cavity/Frame:no insul./2x12 • Ceiling Below Finish:Gypsum Board WATER HEATING SYSTEMS 01 02 03 04 05 06 Verified Existing Name Distribution Type Number of Heaters Solar Fraction(%) Status. Condition DHW Sys 1 Standard 1 Annual Existing No Registration Number: 215-A001,1516A-000000000-0000 Registration Date/Time: 2015-01-12 03:50:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-12122014-651 Report Generated.at 2015-01-12 03:26:22. CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name:Residential Building Calculation Date/Tiine:03:24;Mon,Jan 12,2015 Page 6 of 8 Calculation Description:Title 24 Analysis Input File•Name:1502 Berry Residence.xml WATER HEATERS 01 02 03 04 05 06 07 013 Tank Volume Energy Factor or Tank Exterior Standby Loss Name Heater Element Type Tank Type (gal) Efficiency Input Rating Insulation R-value (Fraction) DHW Heater 1 Natural Gas • Small Storage 50 0.525 EF 28000-Btu/hr 0 0 WATER HEATING-HERS VERIFICATION 01 02 03 04 .05 06 07 ' Central Name Pipe Insulation Parallel Piping 'Compact Distribution Point-of Use Recirculation Recirculation DHW Sys 1 n/a n/a n/a n/a n/a nla HVAC SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan. Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System, ! Served Status Condition , HVAC System'I Other Heating and Heating Yes HVAC ' Yes Air Distribution 'HVAC Fan i 2513' Existing No Cooling System Component 1 Systeml-cool System 1 1 HVAC-HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace-Fuel-fired'central furnace 78 AFUE HVAC-COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency , Multi-speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification HVAC Systeml-cool ; NoCooling-No cooling equipment 11.3 No No N/A Registration Number: 215-A0014516A-000000000-0000 Registration Date/Time: 2015-01-12.03:50:46 HERS Provider: ,CaICERTS inc. CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version-CF1R-12122014-651 Report Generated at 2015-01-12 03:26:22 CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name:Residential Building Calculation Date/Time:03:24,Mon,Jan 12,2015 'Page 7 of 8 Calculation Description:Title 24 Analysis Input File Name:1502 Berry Residence-xnil IIVAC- DISTRIBUTION SYSTEMS i 01 02 .03 '04 05 06 07 08 ,09 '08 ' Insulation Supply Duct Return Duct ; Verify Existing HERS Name Type Duct Leakage 1 R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing,(not 4.2 Attic Attic None Existing No NIA System 1 specified) 'AQ(Indoor Air Quality)FANS , 01 02 03 04 05 • Name 'IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification ' SFam IAQVentRpt 0 Default Q Not Required ! Registration Number: 215-A0014516A-000000000-0000 Registration Date/Time: 2015-01A2 03:50:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards--2013 Residential Compliance Report Version-CF1R-12122014-651 Report Generated at 2015-01-12 03:26:22 CERTIFICATE OF COMPLIANCE-RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residential Building Calculation Date/Time:03:24,Mon,Jan 12,2015 Page 8 of 8 Calculation Description:Title 24 Analysis Input File Name:1502 Berry Residence.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1.I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Josh Miner 366rd Company: Signature Date: J.M Title 24 Services 2015-01-12 03:50:46 'Address: CEA/HERS Certification Identification(If applicable): 4353 Hyland Ave na City/Stale/Zip: Phone: San Jose, CA 95127 408-394-6882 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury,under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24,Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents. worksheets,calculations,plans and specifications submitted to the enforcement agency for approval with this:building permit application. Responsible Designer Name: Responsible Designer Signature: Josh Miner f /0 Company: Date Signed: J.M Title 24 Services 2015-01-12 03:50:46 Address: License: 4353 Hyland Ave na City/State/Zip: Phone: San Jose, CA 95127 408-394-6882 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document,and in no way implies Registration Provider responsibility,for the accuracyof the information. 'Registration Number: 215-A0014516A-000000000-0000 Registration Date/Time: 2015-01-12 03:50:46 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards-.2013 Residential Compliance Report Version-CF1R-12122014-651 Report Generated at 2015-01-12 03:26:22 • RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type m Single Family 0 Addition Alone Date Berry Residence 0 Multi Family m Existing+Addition/Alteration 1/12/2015 Project Address California Energy Climate Zone Total Cond.Floor Area Addition #of Units 21610 Edward Way Cupertino CA Climate Zone 04 2,513 0 2 INSULATION Area Construction Type Cavity (ft2) Special Features Status Floor Wood Framed w/Crawl Space -no insulation 1,558 Existing Wall Wood Framed -no insulation 1,943 Existing Door Opaque Door -no insulation 33 Existing Roof Wood Framed Attic R 19 1,558 Existing Wall Wood Framed R 13 184 New Roof Wood Framed Attic R 30 38 New Demising Wood Framed w/o Crawl Space -no insulation 50 Altered FENESTRATION Total Area: 305 Glazing Percentage: 12.1% New/Altered Average U-Factor. 0.40 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status Front(N) 56.0 0.550 0.67 none none Bug Screen Existing Left(E) 12.0 0.550 0.67 none none Bug Screen Existing Rear(S) 53.3 0.530 0.65 none none Bug Screen Existing Rear(S) 101.3 0.550 0.67 none none Bug Screen Existing Front(N) 66.0 0.400 0.40 none none Bug Screen New Rear(S) 4.6 0.400 0.40 none none Bug Screen New Skylight 6.0 0.400 0.40 none none None New Skylight 6.0 0.400 0.40 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78%AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC System Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 6.3 by EnergySoft User Number. 7674 RunCode:2015-01-12T03:28:20 ID:1502 Page 11 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3) MF-1R Project Name Date Berry Residence 1/12/2015 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1R, CF-1R-ADD, or CF- 1 R-ALT Form)shall supersede the items marked with an asterisk(*) below.This Mandatory Measures Summary shall be incorporated into the permit documents,and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: §110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products(except field-fabricated windows)have a label listing the certified U-Factor,certified Solar Heat Gain Coefficient(SHGC),and infiltration that meets the requirements of§10-111(a). §110.7: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. §110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§110.8(i)when the installation of a Cool Roof is specified on the CF-1R Form. *§150.0(a):Minimum R-30(R-19 for Additions/Alterations) insulation in wood-frame ceiling or equivalent U-factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood-frame wall(R-19 in 2x6)or equivalent U-factor. *§150.0(d): Minimum R-19 insulation in raised wood-frame floor or equivalent U-factor. §150.0(f):Air retarding wrap is tested, labeled,and installed according to ASTM E1677-95(2000)when specified on the CF-1R Form. §150.0(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(l):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor pemieance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q)Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U-factor of 0.58. 2.The weighted average U-factor of all fenestration, includingskylight products,shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area,whichever is greater, is exempt from the maximum U-factor requirement. §150.0(r)Solar Ready Buildings.Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)1A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device. §150.0(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning,Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment,water heaters,showerheads,faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention,pump isolation valve, and recirculation loop connection requirements of§110.3(c)5. §110.5:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and spa heaters. §150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 110.2(c). §150.0(j)1A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.0(j)1 B: Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number. 7674 ID:1502 Page 12 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3) MF-1R Project Name Date Berry Residence 1/12/2015 §150.0(j)2A: All domestic hot water system piping conditions listed below,whether buried or unburied,must be insulated per TABLE 120.3-A. i.The first 5 feet(1.5 meters)of hot and cold water pipes from the storage tank. ii.All piping with a nominal diameter of 3/4 inch(19 millimeter)or larger. iii.All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v.Piping buried below grade. vi.All hot water pipes from the heating source to the kitchen fixtures. §150.0(j)2:Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards Table 120.3-A. §150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture,equipment maintenance, and wind. §150.00)4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections 601,602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181A,or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch,the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)7: Exhaust fan systems have back draft or automatic dampers. §150.0(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible,manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight,moisture,equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters,whether tank or on-demand,to serve individual dwelling units shall include all the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent,or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater,and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating or a pilot light. §110.4(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction and return lines,or built-up connections for future solar heating. §110.4(b)2:Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150.0(p): Residential pool systems or equipment meet the pump sizing,flow rate, piping,filters, and valve requirements of§150.0(p). Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high-efficacy or low-efficacy for compliance with Section 150.0(k)in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1 C:The wattage of permanently installed luminaires shall be determined as specified by§130.0(c). §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency<=20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number. 7674 ID:1502 Page 13 of 15 4- MANDATORY MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3) MF-1R Project Name Date Bent'Residence 1/12/2015 §150.0(k)1 F: Lighting integral to exhaust fans,in rooms other than kitchens,shall meet the applicable requirements of§150.0(k). §150.0(k)2:All switching devices and controls shall meet the requirements of§150.0(k)2. §150.0(k)3:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A.A minimum of one high efficacy luminaire shall be installed in each bathroom;and B.All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms,and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms,garages, laundry rooms, and utility rooms shall,be high efficacy,or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A For single-family residential buildings,outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be highefficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below;and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol;or b.Astronomical time clock not having an override or bypass switch that disables the astronomical time clock,and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5;does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A For low-rise multi-family residential buildings,outdoor lighting for private patios,entrances, balconies,and porches;and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A;or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7,and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units,outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7,and 141.0. §150.0(k)9D:Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7,and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8;OR not contain a screw-base socket, and consume no more than five watts of power as determined according to§130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6,and 141.0. §150.0(k)12A. In a low-rise multi-family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi-family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6,and 141.0;and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent.The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.3 by EnergySoft User Number. 7674 ID:1502 Page 14 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Berry Residence 1/12/2015 System Name Floor Area HVAC System 2,513 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG.PEAK Heating System CFM Sensible Latent CFM Sensible Output per System _ 0 Total Room Loads 1,287 26,615 1,480 1,239 46,990 Total Output(Btuh) 0 Return Vented Lighting 0 Output(Btuh/sgft) 0.0 Return Air Ducts 1,077 2,433 Cooling System Return Fan 0 0 Output per System 0 Ventilation 0 0 0 0 0 Total Output(Btuh) 0 Supply Fan 0 0 Total Output(Tons) 0.0 Supply Air Ducts 1,077 2,433 Total Output(Btuh/sgft) 0.0 Total Output(soft/Ton) 0.0 TOTAL SYSTEM LOAD 28,769 1,480 51,856 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow(cfm) 0 Furnace 0 0 0 Airflow(cfm/sgft) 0.00 Airflow(cfm/Ton) 0.0 Outside Air(%) 0.0% Total Adjusted System Output 0 0 0 Outside Air(cfm/sgft) 0.00 (Adjusted for Peak Design conditions) Note:values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS(Airstream Temperatures at Time of Heating Peak) 28°F 66°F 105°F i^ __ Ilr Outside Air CCC11Y .a- '0 cfm Heating Coil 103°F ROOM 66°F 68°F t X 4 A I COOLING SYSTEM PSYCHROMETICS(Airstream Temperatures at Time of Cooling Peak) 88/68°F 76/62°F 55/54°F lo ..0" O. ► ►H r Outside Air .. = Oif 0 cfm Cooling Coil 56/54°F A 46.7% ROOM t ` ., Ali 76/62°F _ _ 75/62°F 1 4 - A EnergyPro 6.3 by EnergySoft User Number. 7674 RunCode:2015-01-12T03:28:20 ID:1502 Page 15 of 15 ' vii WATER-CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE ::V 743V,s. COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUp s 31 O 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 It ' (408)777-3228•FAX(408)777-3333•buildinicupertino.orq Owner Name l l L-( I 4M. '3 y 4-Te V3etf Permit No. Address (X (6 r 0 c r - o 6J#1-Y CUP /00 e� ?S7// : S�fRu�.`�5r ♦ w' . .t yS f� � c,c 's-�� H ^4 : 1 �rq ♦ ate,"1� yYw3-7z� �. .' G ER C\ No BEtTi\Lrl) flCoI , wsT L HIS`CERTC i. &a% s s� 8� mNFDcvL( 0 � rgigtOS{ ' Fr L ! . � t > . � r �S�' X I M1 .. .. . .s .. rowootin' refer to the attached California Civil Code Sections 1101.1-1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.n Owner'Signature: Date: /Q///A3"' ie No Go to Question 2. .Qr 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. Owner' Signature: Q Date: i 2/4445-- T;/f"-No Go to Question 3. e), '-'r/32 -1- C>2 e), -g ,=-)' ---- 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: 6), Date: f 2_h7/��ty(No Go to Question 4. &,....k, c:7, 62,_,...t-1,0,,,,,... 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 thro 1101.8 do not apply. Sign below and skip the rest of the form. Owner'Signature: ; F� . •� owv'` Date: P-//0(/� IYes My real property is built and available r use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. XMy property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building. On or before January 1, 2017,all non-compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures(regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- .., conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant - plumbing fixtures to be replaced with water-conserving plumbing fixtures. SB407 2015.doc revised 02/04/15 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 1/We,the owner(s)of this properly,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-conserving •lumb'.�11 �comply with the requirements as indicated in the tab be w. _ Owner's (or Owner Agent's)Signature: A --wLTJ Date: / Upon completing and signing this Certificate,please return it tt�+S'Building Division in order to final your permit. Non-Compliant Water-Conserving Plumbing Fixture Plumbing Fixture1 . (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type 2013 CPC Ch.4 2013 CPC Ch.4 2013 CPC Ch.4 Water Usage 2013 CALGreen Div.4.3 2013 CALGreen Div.4.3 2013 CALGreen Div.5.3 /Flow Rate Single-Family Multi-Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume(the composite, average flush volume of two reduced flushes and one full flush) Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower,the combined flow rate of all _ showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi,or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets— Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute®60 Lavatory per minute minute @ 60 psi;minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute @60 psi Faucets— Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi,and must gallons per minute @ default to maximum 60 psi,and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable,aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown,it is not required to be upgraded. SB407 2015.doc revised 02/04/15