Loading...
14100182CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20450 STEVENS CREEK BLVD CONTRACTOR: SC BUILDERS INC PERMIT NO: 14100182 OWNER'S NAME: CUPERTINO CITY CENTER BUILDINGS 910 THOMPSON PL DATE ISSUED: 01/07/2015 OWNER'S PHONE: 4089338836 SUNNYVALE, CA 94085 PHONE NO: (408)328-0688 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL APPLE;IST, 4TH AND 5TH FLOOR; COMM .TI TO License ClassLic. 9 VOR Cie INCLUDE ContractorNEW <�( v /25 C Date 01 .y OFFICE, LABS SPACE. 10,000 SQ FT I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $1500000 performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 36901027.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that l have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. 1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST -CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Iss Date: granting of this permit. Additionally, the applicant understands and will comply with all non -point source re tip per the Cupertino Municipal Code, Section 9.18. Signature_ Date 81 o 1vl�- RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (See.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 2 and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Dater) permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, l CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, l must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the l understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature_ Date CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a cupertino.orq ❑ NEW CONSTRUCTION ❑ ADDITION L2 ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT PROJECT ADDRESS J � � 7APN, of c)2_7.Uv OWNER NAME PHONEE-MAIL 31777" (- t"W cD STREET ADDRESS CITY, STATE, ZIP FAX tea{ , a � L� � Cv �ee:7-too,C5a a 14 CONTACT NAMEPHONE .> Hog.133 883 E-MAIL STREET ADDRESS I zt++ 1 a, LnoP CITY, STATE, ZIP �; C� atzT r`c� C'GA Cit So lwr, FAX ❑ OWNER ❑ OWNER -BUILDER ❑ O - ER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITEC / ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME. G ?D \j LICENSE NUMBERLICENSEFYPE 1 �v .I t q �-e16 BUS LIC k COMPANY NAM[ �.� ?Jv,t.D�CLS, z�G- E-MAIL i'�-uSC.b� �LD'tiQS nk.. Co FAX STREET ADDRESS 1 �1 �c� Q$orl � � CITY,E,ZIP SQ,A VI•LG CIA ��O PHONE �O . Sa$• C71o6'�- ARCItITECT/ENGINEER NAME LICENSE NUMBER BUS LIC 9 Glace 4�2 GI`��S COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP Soak PHONE Lk)S . DESCRIPTION OF WORK WDD rT nO b+ SSC V 2t : Ve5� I $J ULS TO C-C:S �$ <SnL )Yc>o 2S�llrcl� 1 ti 0i V- Q'v D\V\CP'T' t1 IE CPA\JC��ZCt CANS- �iJQ rig T Off\CC) EXISTING USE PROPOSED USE CONSTR TYPE 9STORIES 'JI+asS —b S USE TYPE OCC, SQ.FT. VALUATION (S) EXISTG NEW FLOOR DEMO TOTAL AREA . —1 AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKTORCH AREA GARAGE .AREA DETACH E] ATTACK At DWELLING UNITS IS A SECOND UNIT [] YES SECOND STORI' []YES BEING ADDED? ED ADDITION? ❑NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEIVED BY: �,�" TOTAL VALUATION: PLANNING APDL b ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO r/' By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct.i e r the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to bili it o construe I juthorize resentatives of Cupertino to enter lire above -identified property for inspection purposes. Signature of Applicant/Agent Dale: �Zo� �'t. �ol SUPPLEMENTAL INEOR REQUIRED PLANCHECKT]TE ROUTING SLIP ❑ OVER-THE-COUNTER �BUILDINGPLANREVIEW New Sf D Or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed I IazardouS Materials DISCIOSUre AIFANDARD ❑ PUBLIC WORKS form If ail)' I lazarclous Materials are being Used as part Of this pr0)ect. ❑ LARGE le FIRE DEPT __ Copy of Planning Approval Letter or Meeting With Planning prior to El submittal Of Building Permit application. MAJOR SANITARY SEWER DISTRICT ❑ ENVIRONNIENTAL HEALTH B1c1gAj)p 201 ].d Jc revised 0012! /1 / CITY OF CUPERTINO I�/II FEE ESTIMATOR -BUILDING DIVISION OCCUPANCY TYPE: ADDRESS: 20450 scb DATE: 10/30/2014 REVIEWED BY: Mendez PC FEE ID APN: BP#: ?" *VALUATION: 1$1,500,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Tenant Improvement PRIMARY Commercial Building USE: IBTIPLNCK PENTAMATION 1 B TI PERMIT TYPE: WORK comm. t.i SCOPE Suppl. Insp. Feer Reg. Q OT OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA (s.f.) PC FEES PC FEE ID BP FEES BP FEE ID B (Tenant Improvements) I -AJ -B 10,000 $4,053.80 IBTIPLNCK $9,850.20 IBTIINSP Permit Fee: $9,850.20 Suppl. Insp. Feer Reg. Q OT 0,0 lirs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? 0 Yes Q) No $0.00 TOTALS: 10,000 1 $4,053.80 1 $9,850.20 Strong Motion Fee: 1BSEISMICO MECH, HOURLY Yes G No PLUMB, HOURLY 0 Yes G No ELEC, HOURLY ®" Yes (E) No fold:?-C�i .ii .. �s""'•�j') NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School Dictrirt otr_ 1_ Thoco foot aro hacod nn tho nroliminam information availahlo and aro only an -comate_ Cnntaet the Dent for addn'1 info_ FEE ITEMS (Fee Resolution 11-053 E . 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $4,053.80 Select a Misc Bldg/Structure or Element of a Building Suppl. PC Fee: ) Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $9,850.20 Suppl. Insp. Feer Reg. Q OT 0,0 lirs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? 0 Yes Q) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential 0 Building or Structure 0 i Strong Motion Fee: 1BSEISMICO $420.00 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $60.00 SUBTOTALS: 14,384.001 $0.001 TOTAL FEE: 1 $14,384.00 Revised: 10/01/2014 Building Department C'rtc Of Cupertino IGV10 Tb,it .Av;nu, CA 95014-3?,; Tele;,h, e: -tip--- Fax: KJS___� 1 CONTRACTOR / SUBCO\TR_-�CTOR LIST 1Q11-3 AUI)IZI~S5: 2Q4 50 S ver+ S �Y�t vd E PHRMIT at; NER ti°AML: bFnl G PHON . - o R 33 bS3(o C,E' FR,1I_ C'O C -TOR: SC/ fail d _ ..._..-.__ tv5 nG � � BUSINESS t_10ENSE ADDRr__s�:glo�om� „" P1a� -- -- _..._ ctrl r11�co�i 5Lv, y Aj r- Ct4-D85-- ``Our municipal code requires all businesses working in the cite to ha%e a Chin of Cupertino husiness lieense. NO BUILDING FINAL Oil YINM., OCCUPANCY I\SIIECTIO\(S) "ILL BE SCHEDULED U.NT.IL THE GENERAL CO\TR-AC ORA D ALL S1-II('0\1IZ-`tC'1-0R5 HAVE OBT1I\FI) A C'll'r OF CUPERTI\0 BUSI.NLSS LICENSE. I am not usin,nani subcontractors: SInnarllre I);1tL Please check applicable subcontractors and complete the follosiins; information: ✓ SUBCONTRACTOR BUSINESS NAME - BUSINESS LICENSE ;F Cabinets C Millwork Ccrnznt Finishing N! J ! Electrical _ iLidWG��i G�eC.tG C'tYcs �I to 0 Excavation N%Q Fencing J Flooring /Carpeting, Linoleum I Wood Cara%rA C A -t PiDoll(✓�A 1 1AIZi r- l Glass iGlazingTyi V�tiU S L.'�1rS 32�'le-1 Z IICad nEl ei4ror, IIAXUAA MiCAAAv i6AJ 12(A.y i f In3ulatttrn Sgyn� aS -54n-tom" t�DC.k - ___ i _ Landscaping- i Lathina 'Irl p i Masonr v ✓ ?Painting Wallpoper Paving - IN #Q Plasterina j ✓ Plumbing i✓�-1 NL{C�ILGtM�ti�ctQ '?�rso2 Roohne Septic Tank Sheet Metal — SiG j -i %a,{ -i►^-`) Ai 947vf- - , ' ,J Sheet Rock _ J Mti vt,ttn+n.� (�trv�W61..I.,W ,- --E 1018200 f Tile _.__ tiincr,Co ractnr_Si�nanrre - -- Date STATEMENT OF SPECIAL INSPECTIONS, 2013 CW, COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION �' .. i E,•. jALBERT SALVADOR, P.E , C B 0, BUILDING OFFICIAL �. �� ( CUPERTI N 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 O (406) 777-3228 • FAX (408) 777-3333. tuld'naftivioerting org SITE 046 Stevens Creek Blvd (Ph 2 -1st, 4th, & Sth Floors) APN sp#ADORE Dwrw..ApRh...__.. Contractor,SC ,BuliderS.................................. _..., Address,7Arif rite.19.01?.._.._.................... ..... .,................._... Address .9IQ Th.Qm P. Q. n. Maw................. ,. ,...... ........ . ...... city/St .CuPerlln:o..C.P.►.... ......zip.2604.......... . Phone....Qaae).._._..,.. citytst.SurinmO ........... .....zip..Ca.,..._...Phone.9400._.., . Ownss Authorizatiiotn Signature ............ ........ ............................................... .......... Date..............,.......... Applicant ��t ..i {II,i¢f;}....................._...............,._.............. EngineedArchitect..StudloS,Architecture address. 910 Tharnpson.,Qlace........_._... ..... Address 4Q5 Howard Street,_Sulte,488 ,,zip....4rA...._....... _.Pnone_.; 4Q$b,..., Cit ist. San Fr3f1C15c0 ..: 9A Phone .041.Q_5...... PROJECT DESCRIPTION. Minor demo and tenant improvement of 1st, 4th, and 6th floors for private offices and open offices ace. This 'STATEMENT OF SPECIAL INSPECTIONS' Is submitted in fulfillment of the requirements of CBC Sections 1704 and 1705. This form is structured after and used by permission from the �UWW al E!2+neer Assccaatirn of _N!xlhem Callfc?rnia's (SEAONC) mode statement of Special Inspections. Also, Included with this form is the following, ❑ 'LIST OF SPECIAL INSPECTION AGENCIES (page 2). A list of testing agencies and other special Inspectors that will be retained to conduct the tests and inspections for this project ❑ 'SCHEDULE OF SPECIAL INSPECTION' (page 3 —6). The Schedule of Special Inspections summarizes the Special Inspections and tests required. Special Inspectors will refer to the approved plans and specifications for detailed special inspection requirements. Any additional tests and Inspections required by the approved plans and specifications shall also be performed. Special Inspections and Testing will be performed in accordance with the approved plans and specifications, this statement and CBC Sections 1704, 1705, 1706, 1707, and 1708. Interim reports will be submitted to the Building Official and the Registered Design o Professional in Responsible Charge in accordance with CBC Section 1704.1.2 A Final Report of Special Inspections documenting required Special Inspections, testing and correction of any discrepancies noted In the Inspections shall be submitted prior to issuance of a Certificate of Use and Occupancy (Section 1704.1.2). The Final Report will document; • Required special Inspections, • Correction of discrepancies noted In Inspections, The Owner recognizes his or her obligation to ensure that the construction complies with the approved permit documents and to Implement this program of special inspections. In partial fulfillment of these obligations, the Owner will retain and directly pay for the Special Inspections as required in CBC Section 1704.1. This plan has been developed with the understanding that the Building Official will: • Review and approve the qualifications of the Special Inspectors who will perform the inspections. • Monitor special inspection activities on the job site to assure that the Special Inspectors are qualified and are performing their duties as called for in this Statement of Special Inspection. • Review submitted inspection reports. • Perform Inspections as required by the local buadmg code. 1 have road and aarse to comnty with the terms and conditions of this statement Prepared By: Project W Engineer O Architectl SE5192 11.19.14 Re istered Professional in Cha a Slanalure ......... /.1 ... ........ ........ .........Uc# ...—....... ... ... .. ............ Date ........ ..__ .... Owner N rtte: Rt� C Ownss Authorizatiiotn Signature ............ ........ ............................................... .......... Date..............,.......... Inspection Agency Inspector Name: i'h oNr crf legAleX ..............__.`_.............. . Date, ..f...l..a.!i,..., Building Utficfal or designee Skinature........................_............................................ f ................. ! ..... " r012 docrevised 09106112 APPROVAL OF SPECIAL INSPECTORS" Each special inspection agency, testing facility, and special inspector shall be recognized by the Building Official prior to performing any duties. Special Inspection agency's listed on this form must be pre -approved and listed or, Cupertino's approved Special Inspector's list. Special inspectors shall carry approved identification when performing the functions of a special inspector. Identification cards shall follow the criteria set by the C:r_Itfornip Gojna of -.1--sung arra Inspect, n P:, :ee. No personnel changes shall be made without first obtaining the approval of the Building Oficial. Any unauthorized personnel changes may result in a 'Stop '' fork Order' and possible permit revocation. To be pre- approved by the City of Cupertino, refer to the SPECIAL INSPECTION CRITERIA handout. Please allow riwo weeks to complete the application process. The following are the testing and special inspection agencies that will be retained to conduct tests and inspection on this project: EXPERTISP FIRM f INSPECTOR INFORMATION 1. Special Inspection (except for Firm.:.a'�-, . t r, ` . = . F . . .................... Addr...'.:?.`..........'............................................ geotechnical) city 1- ...................`..................................... .i .................... . ..Zip St ................. . -....:.. leph.e:nea.L�'. ax.': r......... Emai1..4 ;.: Gly 4 .i c'. ? sa.,a .:....:.� ...:. 2. Material Testing Firm..............Addr..�.`€.c?...0%;�il�;cl .�....: �.d.:................. City.SA.eJ.rrzr..°'....�S.f.:J............................................................State....!;? m&...........Zip..`.?.i.:..:�1.... Telephone...`.{.t.r.... ............ � ..Fez.....'•..;:..:..°`..:. �......... Email . ..... :...... ,e,R, 3. Geotechnical Inspections Firm ............ ........ __......... ................................... -Addr................ ..................... ......................... ........... ................ City-..............................................................................................._....... State .............. ......... Zip ...................... Telephone..................................... Fax ....................... ................... - Email ............................................ ............. 4. Other: Firm.....................................................................Addr......................................................................................... City.......................................................................................................... State .......................Zip .... I., ............. .. Telephone. ...... . ....... .......... ........ Fax............................................ Email ....... .................. ........................... ..... *All agencies specified on this form must be pre -approved and listed on the City of Cupertino's Approved Special Inspector's List. SEISMIC REQUIREMENTS (Section 9706.3.6) Description of seismic -force -resisting system and designated seismic systems subject to special inspections as per Section 1705.3: The extent of the seismic -force -resisting system is defined in more detail in the construction documents. Description of main wind -force -resisting system and designated wind resisting components subject to special inspections in accordance with Section 1705.4.2: The extent of the main wind -force -resisting system and wind resisting components is defied in more detail in the construction documents. Speciah7speciioi?kor:,i.i012 floc re viscd 09,%0671 SCHEDULE OF SPECIAL INSPECTION SITE APN BP# ADDRESS PROJECT DESCRIPTION: Notation Used in Table: Column headers: C Indicates continuous inspection is required. P Indicates periodic inspections are required. The notes and/or contract documents should clarify. Box entries: X Is placed in the appropriate column to denote either "C" continuous or "P" periodic inspections. --- Denotes an activity that is either a one-time activity or one whose frequency is defined in some other manner. Additional detail regarding inspections and tests are provided in the project specifications or notes on the drawings. VERIFICATION AND INSPECTION C P REFERENCED IBC REFERENCE STANDARD INSPECTION OF FABRICATORS 1. ❑ Inspect fabricator's fabrication and quality control 1704.3 procedures. INSPECTION OF STEEL 1. Material verification of high-strength bolts, nuts and washers. ❑ Identification marking to conform to ASTM stds AISC 360, specified in the approved construction documents. --- X Section A3.3 and applicable ASTM material standards ❑ Inspect fabricator's fabrication and quality control X procedures. - -- 2. Inspection of high-strength bolting: ❑ Snug -tight joints. --- X ❑ Pretensioned and slip -critical joints using turn -of -nut with matchmarking, twist -off bolt or direct tension --- X AISC 360, indicator methods of installation. 1704.3.3 Section M2.5 ❑ Pretensioned and slip -critical joints using turn -of -nut without matchmarking or calibrated wrench methods X --- of installation. 3. Material verification of structural steel and cold -formed steel deck. ❑ For structural steel, identification markings to conform X AISC 360, to AISC 360. Section M2.5 ❑ For other steel, identification markings to conform to Applicable ASTM ASTM standards specified in the approved --- X material standards construction documents. ❑ Manufacturer's certified test reports. --- X SpeciabzspectionForm_2012.doc revised 09/06/12 VERIFICATION AND INSPECTION C p REFERENCED STANDARD IBC REFERENCE 4. Material verification of weld filler materials: ❑ Identification marking to conform to AWS specification in the approved construction documents. --- X AISC 360, Section A3.5 and applicable AWS A5 documents -- ❑ Manufacturer's certificate of compliance required. --- X --- --- 5. Inspection of welding: a. Structural steel and cold -formed steel deck: ❑ Complete and partial joint penetration groove welds. X --- AWS D1.1 1704.3.1 ❑ Multipass fillet welds. X --- ❑ Single -pass fillet welds > 5/16" X --- ❑ Plug and slot welds. X --- ❑ Single -pass fillet welds <= 5/16" --- X ❑ Floor and roof deck welds. --- X AWS D1.3 b. Reinforcing steel: ❑ Verification of weldability of reinforcing steel other than ASTM A 706. - X AWS D1.4 ACI 318: Section 3.5.2 ❑ Reinforcing steel resisting flexural and axial forces in intermediate and special moment frames, and boundary elements of special structural walls of concrete and shear reinforcement. X -_- ❑ Shear reinforcement. X --- ❑ Other reinforcing steel. --- X 6. Inspection of steel frame joints details for compliance: ❑ Details such as bracing and stiffening. --- X --- 1704.3.2 ❑ Member locations. --- X ❑ Application of joint details at each connection. --- X VERIFICATION AND INSPECTION C p REFERENCED STANDARD IBC REFERENCE INSPECTION OF WELDING 1. ❑ Welded studs when used for structural diaphragms. --- X --- 1704.3 2. ❑ Welding of cold -formed steel framing members. --- X �3. ❑ Welding of stairs and railing systems. --- X SpecialnspectionForm_2012.doc revised 09106112 VERIFICATION AND INSPECTION C p REFERENCEDIBC STANDARD REFERENCE INSPECTION OF CONCRETE 1. ❑ Inspection of reinforcing steel, including prestressing X ACI 318: 3.5, 7.1-7.7 1913.4 tendons and placement. 2. ❑ Inspection of reinforcing steel welding in accordance AWS D1.4 ACI 318: with Table 1704.3 Item 5b, 3.5.2 3. ❑ Inspection of bolts to be installed in concrete prior to and during placement of concrete where allowable X -_ ACI 318: 8.1.3, 1911.5, 1912.1 loads have been increased or where strength design 21.2.8 is used. 4. ❑ Inspection of anchors installed in hardened concrete. --- X ACI 318: 1912.1 5. ❑ Verifying use of required design mix. 1904.2.2,1913.2, -_- X ACI 318: 1913.3 6. ❑ At time fresh concrete is sampled to fabricate ASTM C 172 specimens for strength tests, perform slump and air X --- ASTM C 31 1913.10 content tests and determine the temperature of the concrete. ACI 318: 5.6, 5.8 7. ❑ Inspection of concrete and shotcrete placement for X --- ACI 318: 5.9, 5.10 1913.6, 1913.7, proper application techniques. 1913.8 8. ❑ Inspection for maintenance of specified curing --- X ACI 318: 5.11-5.13 1913.9 temperature and techniques. 9. Inspection of prestressed concrete: ❑ Application of prestressing forces. X --- ACI 318:18.20 ❑ Grouting of bonded prestressing tendons in the--- X --- ACI 318: 18.18.4 seismic force -resisting system. 10. ❑ Erection of precast concrete members. --- X ACI 318: Ch. 16 --- 11. ❑ Verification of in-situ concrete strength, prior to stressing of tendons in posttensioned concrete and _-_ X ACI 318: 6.2 --- prior to removal of shores and forms from beams and structural slabs. 12. ❑ Inspect formwork for shape, location, and dimensions ___ X ACI 318: 6.6.1 --- of the concrete member being formed. 13.E Bolts Installed in Existing Masonry or Concrete ❑ Direct tension testing of existing anchors. --- X See ICC ES Reports form special inspection requirements for proprietary products ® Direct tension testing of new bolts. --- X Torque testing of new bolts. --- X ;M Prequalification test for bolts and other types of X anchors. 14. ❑ Other: SpecialnspectionForm_2012.doe revised 09/06/12 SpecialnspectionForm_2012.doc revised 09106/12 REFERENCE FOR CRITERIA VERIFICATION AND INSPECTION C P IBC TMS 402/ACI TMS 402/ACI SECTION 530/ASCE 5 530/ASCE 6 INSPECTION OF LEVEL 1 MASONRY 1. ❑ Compliance with required inspection provisions of the construction documents and the approved --- X --- --- Art. 1.5 submittals shall be verified. 2. ❑ Verification of f'R, and franc prior to construction X --- --- Art. 1.413 except where specifically exempted by this code. 3. ❑ Verification of slump flow and VSI as delivered to X --- --- --- Art. 1.513.1.b.3 the site for self consolidating grout. 4. As masonry construction begins, the following shall be verified to ensure compliance: ❑ Proportions of site -prepared mortar. --- X --- --- Art. 2.6A ❑ Construction ofmortarjoints. --- X --- --- Art.3.313 ❑ Location of reinforcement, connectors, X --- --- Art. 3.4, 3.6A prestressing tendons, and anchorages. ❑ Prestressing technique. --- X --- --- Art. 3.613 ❑ Grade and size of prestressing tendons and ___ X --- --- Art. 2.413, 2.4H anchorages. 5. During construction the inspection program shall verify: ❑ Size and location of structural elements. --- X --- --- Art. 3.3F ❑ Type, size, and location of anchors, including Sec. 1.2.2(e), other details of anchorage of masonry to --- X --- 1.16.1 ___ structural members, frames or other construction. ❑ Specified size, grade, and type of reinforcement, anchor bolts, prestressing tendons and --- X --- Sec. 1.15 Art. 2.4, 3.4 anchorages. ❑ Welding of reinforcing bars. X --- --- --- ❑ Preparation, construction and protection of masonry during cold weather (temperature below ---x Sec. 2104.3, _-_ Art. 1.8C, 1.81D 40 degrees F) or hot weather (temperature above 2104.4 90 degrees F). ❑ Application and measurement of prestressing X --- --- --- Art. 3.613 force. 6. Prior to grouting the following shall be verified to ensure compliance: ❑ Grout space is clean. --- X --- --- Art. 3.21D ❑ Placement of reinforcement and connectors and ___ X --- Sec. 1.3 Art. 3.4 prestressing tendons and anchorages. ❑ Proportions of site -prepared grout and --- X --- --- Art. 2.613 prestressing grout for bonded tendons. ❑ Construction ofmortarjoints. --- X --- --- Art. 3.313 7. Grout placement: ❑ Grout placement shall be verified ensure X compliance. ___ -_- -_- Art. 3.5 ❑ Observe grouting of prestressing bonded X ___ --- -_- Art 3.6C tendons. SpecialnspectionForm_2012.doc revised 09106/12 SpeciahsspectionForm 2012.doc revised 09/06/12 REFERENCE FOR CRITERIA VERIFICATION AND INSPECTION C P IBC TMS 402/ACI TMS 402/ACI SECTION 530/ASCE 5 530/ASCE 6 8. ❑ Preparation of any required grout specimens, Sec. mortar specimens, and/or prisms shall be --- X 2105.2.2, -- Art. 1.4 observed. 2105.3 INSPECTION OF LEVEL 2 MASONRY 1. ❑ Compliance with required inspection provisions of the construction documents and the approved --- X --- --- Art. 1.5 submittals. 2. ❑ Verification of fmand faac prior to construction and for every 5,000 square feet during --- X --- --- Art. 1.413 construction. 3. ❑ Verification of proportions of materials in premixed or preblended mortar and grout as --- X --- --- Art. 1.513 delivered to the site. 4. ❑ Verification of slump flow and VSI as delivered to X --- --- --- Art. 1.513.1.b.3 the site for self consolidating rout. 5. The following shall be verified to ensure compliance: ❑ Proportions of site -prepared mortar, grout, and --- X --- --- Art. 2.6A prestressing grout for bonded tendons. ❑ Placement of masonry units and construction of --- X --- --- Art. 3.313 mortar joints. ❑ Placement of reinforcement, connectors and --- X --- Sec. 1.15 Art. 3.4, 3.6A prestressing tendons and anchorages. ❑ Grout space prior to grouting. X --- --- --- Art. 3.21D ❑ Placement of grout. X --- --- --- Art. 3.5 ❑ Placement of prestressing grout. X --- --- --- Art. 3.6C ❑ Size and location of structural elements. --- X --- --- Art. 3.3F ❑ Type, size, and location of anchors, including other details of anchorage of masonry to X --- --- Sec.1.2.2(e) --- structural members, frames and other construction. ❑ Specified size, grade, and type of reinforcement, anchor bolts, prestressing tendons and --- X --- Sec. 1.15 Art. 2.4, 3.4 anchorages. ❑ Welding of reinforcing bars. X --- Sec. 2.1.9.7.2, --- 3.3.3.4 (b) ❑ Preparation, construction, and protection of masonry during cold weather (temperature below ___ X Sec. 2104.3, --- Art. 1.8C, 1.8D 40 degrees F) or hot weather (temperature above 2104.4 90 degrees F). ❑ Application and measurement of prestressing X --- --- --- Art. 3.613 force. 6. ❑ Preparation of any required grout specimens, Sec. mortar specimens, and/or prisms shall be X --- 2105.2.2, --- Art. 1.4 observed. 2105.3 SpeciahsspectionForm 2012.doc revised 09/06/12 VERIFICATION AND INSPECTION C p REFERENCED STANDARD IBC REFERENCE INSPECTION OF WOOD 1. ❑ Inspect prefabricated wood structural elements and assemblies in accordance with Section 1704.2. --_ 1704.6 2. ❑ Inspect site built assemblies. --- --- 3. Inspect high -load diaphragms: ❑ Verify grade and thickness of sheathing. --- El Verify nominal size of framing members at adjoining panel edges. --- 1704.6.1 ❑ Verify nail or staple diameter and length, --- --- ❑ Verify number of fastener lines, --- El Verify Verify spacing between fasteners in each line and at edge margins. 4. ❑ Metal -plate -connected wood trusses spanning 60 feet or greater: Verify temporary installation restraint/bracing and the permanent individual truss --- X --- 1704.6.2 member bracing are installed in accordance with the approved truss submittal package. REQUIRED VERIFICATION AND INSPECTION OF SOIL 1. ❑ Verify materials below footings are adequate to X achieve the desired bearing capacity. - 2. ❑ Verify excavations are extended to proper depth and X have reached proper material. - 3. ❑ Perform classification and testing of compacted fill materials. _ _ X --- Table 1704.7 4. ❑ Verify use of proper materials, densities and lift thicknesses during placement and compaction of X --- compacted fill. 5. ❑ Prior to placement of compacted fill, observe subgrade and verify that site has been prepared properly. _ _ X REQUIRED VERIFICATION AND INSPECTION OF DEEP DRIVEN FOUNDATION ELEMENTS 1. ❑ Verify element materials, sizes and lengths comply X - - with the requirements. 2. ❑ Determine capacities of test elements and conduct X additional load tests, as required. 3. ❑ Observe driving operations and maintain complete X --- and accurate records for each element. 4. ❑ Verify locations of piles and their plumbness, confirm type and size of hammer, record number of blows per --- Table 1704.8 foot of penetration, determine required penetrations to X --- achieve design capacity, record tip and butt elevations and document any damage to foundation element. 5. ❑ For steel elements, perform additional inspections in accordance with Section 1704.3. 6. ❑ For concrete elements and concrete filled elements, perform additional inspections in accordance with --- --- Section 1704.4. SpecialnspectionForm_2012.doc revised 09/06/12 VERIFICATION AND INSPECTION C p REFERENCED IBC STANDARD REFERENCE 7. ❑ For specialty piles, perform additional inspections as determined by the registered design professional in --- --- --- Table 1704.8 responsible charge. REQUIRED VERIFICATION AND INSPECTION OF CAST -IN-PLACE DEEP FOUNDATION ELEMENTS 1 ❑ Observe drilling operations and maintain complete and X --_ accurate records for each element. 2. ❑ Verify placement locations and plumbness, confirm element diameters, bell diameters (if applicable), lengths, embedment into bedrock (if applicable), and X --- --- Table 1704.9 adequate end -bearing strata capacity. Record concrete or grout volumes. 3. ❑ For concrete elements, perform additional inspections in accordance with Section 1704.4. HELICAL PILE FOUNDATIONS 1. ❑ Record installation equipment used, pile dimensions,X 1704.10 tip elevations, final depth, final installation torque. SPRAYED FIRE-RESISTANT MATERIALS Physical and visual tests 1. Condition of substrates. ❑ Inspect surface for accordance with the approved fire - resistance design and the approved manufacturer's --- --- written instructions. ❑ Verify minimum ambient temperature before and after application. X ❑ Verify ventilation of area during and after application. --- X 2. ❑ Measure average thickness per ASTM E605 and S Section 1704.12.4. --- '-- --- 1704.12.1 3. ❑ Verify density of material for conformance with the approved fire-resistant design and ASTM E605. (Ref. --- --- Section 1704.12.5) 4. ❑ Test cohesive/adhesive bond strength per Section 1704.12.6. 5. ❑ Condition of finished application. MISCELLANEOUS 1. Mastic and Intumescent Fire -Resistant Coating. --- --- --- 1704.13 2. Exterior Insulation and Finish Systems (EIFS). Water - resistive barrier coating when installed over a sheathing --- --- --- 1704.14 substrate. 3. Special Cases --- --- --- 1704.15 4. Smoke Control System --- --- --- 1704.16 5. Seismic Resistance ❑ Suspended ceiling systems and their anchorage. --- --- --- 1705.3 [4.3] SpecialnspectionFonn_2012.doc revised 09/06/12 VERIFICATION AND INSPECTION C p REFERENCED STANDARD IBC REFERENCE 6. Wind Resistance ❑ Roof cladding and roof framing connections. --- --- --- ❑ Wall connections to roof and floor diaphragms and framing. ❑ Roof and floor diaphragm systems, including collectors, drag struts and boundary elements. ❑ Vertical wind -force -resisting systems, including braced frames, moment frames, and shear walls. ❑ Wind -force -resisting system connections to the foundation. ❑ Fabrication and installation of systems or components required to meet the impact resistance requirements --- --- --- of Section 1609.1.2. SPECIAL INSPECTION FOR WIND REQUIREMENTS 1. Structural Wood ❑ Inspect field gluing operations of elements of the main X wind -force -resisting system. ___ 1706.2 ❑ Inspect nailing, bolting, anchoring, and other fastening of components within the main windforce-resisting -__ X system, including wood shear walls, wood diaphragms, drag struts, braces and hold-downs. 2. Cold -Formed Steel Framing ❑ Welding of elements of the main wind -force -resisting system. -_- X ❑ Inspection of screw attachments, bolting, anchoring, and other fastening of components within the main --- 1706.3 wind -force -resisting system including shear walls, --- X braces, diaphragms, collectors (drag struts) and hold- downs. 3. Wind -resisting components ❑ Roof cladding. --- X --- 1706.4 ❑ Wall cladding. --- X SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE 1. ❑ Special inspection for welding in accordance with the -- 1707.2 quality assurance plan requirements of AISC 341. 2. Structural Wood ❑ Inspect field gluing operations of elements of the X --- seismic-force-resisting system. ❑ Inspect nailing, bolting, anchoring, and other fastening of components within the seismic -force -resisting 1707.3 system, including wood shear walls, wood --- X diaphragms, drag struts, braces, shear panels and hold-downs. 3. Cold -Formed steel light -frame construction ❑ Welding of elements of the seismic -force -resisting X 1707.4 system. SpecialnspectionForm_2012.doc revised 09/06/12 ❑ Inspection of screw attachments, bolting, anchoring, and other fastening of components within the seismic- X force -resisting system including shear walls, braces, -_ diaphragms, collectors (drag struts) and hold-downs. 4. Storage racks and access floors ❑ Anchorage of storage racks 8 feet or greater in height___ X 1707.5 and access floors. 5. Architectural components ❑ Inspect erection and fastening of exterior cladding weighing more than 5 psf and higher than 30 feet --- X above grade or walking surface. ❑ Inspect erection and fastening of veneer weighing more than 5 psf.and higher than 30 feet above grade --- X or walking surface. --- 1707.6 ❑ Inspect erection and fastening of all exterior non- bearing walls higher than 30 feet above grade or --- X walking surface. ❑ Inspect erection and fastening of all interior non- bearing walls weighing more than 15 psf and higher --- X than 30 feet above grade or walking surface. 6. Mechanical and Electrical Components ❑ Inspect anchorage of electrical equipment for emergency or stand-by power systems. --- X ❑ Inspect anchorage of non -emergency electrical X equipment. ❑ Inspect installation of piping systems and associated mechanical units carrying flammable, combustible, or --- X --- 1707.7 highly toxic contents. ❑ Inspect installation of HVAC ductwork that contains X hazardous materials. - ❑ Inspect installation of vibration isolation systems where required by Section 1707.7. _ - X 7. ❑ Verify that the equipment label and anchorage or mounting conforms to the certificate of compliance 1707.8 when mechanical and electrical equipment must be ___ ___ ___ seismically qualified. 8. ❑ Seismic isolation system: Inspection of isolation -__ X ___ 1707.9 system per ASCE 7 — Section 17.2.4.8 9. ❑ Obtain mill certificates for reinforcing steel, verify compliance with approved construction documents, --- --- --- 1708.2 and verify steel supplied corresponds to certificate. 10. ❑ Structural Steel: Invoke the QAP Quality Assurance 1708.3 requirements in AISC 341. -__ --- ___ 11. ❑ Obtain certificate that equipment has been seismically qualified. ___ 1708.4 12. ❑ Obtain system tests as required by ASCE 7 Section 1708.5 17.8. --- --- ___ SpecialnspectionFonn_2012.doc revised 09/06112 CUPERTIINO RECOGNIZED SPECIAL INSPECTION AGENCY LIST COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - buildingC@cugertino.org The following list of Special Inspection Agencies and their special inspectors are approved by the City of Cupertino to provide specific inspection in their respective field until the expiration date listed. Agency Name, Address and expiration date Special Inspectors RC PC Special Inspection Field SM SW HB FP S W CG Achievement Engineering Corp. 434 Camille Cir. #13 San Jose, CA 95134 Tel: (800) 653-1397 Fax: (408) 852-0331 Expires: 07/22/2015 Firouz'aei, Arash FP = Spray -Applied Fireproofing CG = CalGreen Code X X X X Hooshdar, Sina X X X X Khodadadi, Mohammad X Safaian, Farshad Applied Materials & Engineering, Inc. 980 415t Street Oakland, CA 94608 Tel: (510) 420-8190 Fax: (510) 420-8186 Expires: 12/19/2014 Email: info(aD_aPPmateng.com Aaron Hardy X X X AnthonyKlarich X X X X X Armen Ta'irian, P.E. X Bryan Jackson X X David Jackson X X X X X Diego Bertolino X X X Harold Walrath X X X X Ken Maloney X X Michael Knowles X X X X Oswaldo Dominguez X X X X Sean Guches X X X Bagg Engineers 847 West Maude Ave. Sunnyvale, CA 94085-2911 Tel: (650) 852-9133 Fax: (650) 852-9138 Expires: 7/16/2015 www.bagaengineers.com Brown, Christian X X X X X Cole, Michael Hepper, John X X X Knudsen, Steven J. McManus, Alvin X X X Norris, David L. X X X X O'Driscoll, Alan Salceda, Francisco Sciortino, Brandon Smith, Louis Steinbrueck, Bryan Thai, Minh Umeki, Takashi RC = Reinforced Concrete SW = Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W= Wood SM= Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpeciallnspectionList.doc revised 02/01/14 Agency Name, Address and expiration date Special Inspectors RC Pc Special Inspection Field SM sw Hs FP s w CG Biggs Cardosa Associates, Inc. 865 The Alameda San Jose, CA 95126 Tel: (408) 296-5515 Fax: (408) 296-8114 Expires: 7/11/2014 www.biggscardosa.com Castro, Roberto FP = Spray -Applied Fireproofing CG = CalGreen Code Chan, David X X Ghorbani, Behrooz Lazzarini, Dan Rivas, Ricardo Rosales, Adolfo Rosellini, Daniel Sanchez, Adam To an, Claudiu X X Wooley, Mark X X X X Yamane, Robert BSK Associates Engineers & Laboratories 324 Earhart Way Livermore, CA 94551 Tel: (925) 315-3151 Fax: (925) 315-3152 Expires: 9/06/2014 www.bskassociates.com Auser, Jim X X X Bos ue, Jeff X X X Clary, Mike X X X X Evans, Keven X Minerales, Gilbert Ness, Dennis X X X Olsten, Ken X X Reeves, Ben Rodriguez, Tim X X X Schurman, Peter X Capex Engineering Inc. 571 Seville Place Fremont, CA 94539 Tel: (510) 668-1815 Fax: (510) 490-8690 Expires: 6/25/2014 Gary Hsu X X X X X Chow, Erwin 1105 Belmont Ave. Long Beach, CA 90804 Tel: (562) 449-7491 Expires: 4/24/2014 Erwin Chow X RC = Reinforced Concrete S W = Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W= Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpeciallnspectionList.doc revised 02101114 Agency Name, Address and expiration date Special Inspectors RC PC Special Inspection Field SM SW HB FP S w CG Consolidated Engineering Laboratories 2001 Crow Canyon Road, Suite 100 San Ramon, CA 94583 Tel: (925) 341-7100 Fax: (925) 855-7140 Expires: 6/25/2014 www.ce-labs.com Ahmed, Badaruddin FP = Spray -Applied Fireproofing CG = CalGreen Code Alexander, David X X X Andersen, Calvin X X Bartlett, Dennis X X Bobrovitsk , Edward X X X Bolen, Michael X X X Brooks, Brendan X X X X X Brown, Ronald X X X X X Buchmiller, Kenn Cottingham, Paul Currier, James X X Eschliman, Duaine Eschliman, Kevin Fuller, Mark X X Halloran, James X X X X X Harrington, Wayne X X Hassebrock, Scott X X X X X Healy, Michael X Heilmann, Mark X X X Hornyak, John X X X X Hyslop, John X X X X King, Phillip X X X X Kmitt, Stanley X X Liebold, Jeffrey X X X X X Lozano, Alfonso Art Ma, Steven X Marlik, William X X McCutcheon, Thurmond X X McKenzie, Quinten McLaughlin, Lori X X Miner, Dwight X X Murphy, Don X Pastora, George X X X X Rodriguez, Sandra X X Si mon, Josephine Sisson, James X X X X Small, Michael X X Van Horn, Bradford X X X I I X Walters, Michael Zuerner, Robert X X X RC = Reinforced Concrete SW = Steel & Welding S =Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W= Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpeciallnspectionList.doc revised 02/01/14 Agency Name, Address and expiration date Special Inspectors RC PC Special Inspection Field SM SW HB FP s w CG Construction Testing Services 2174 Rheem Dr., Ste. A Pleasanton, CA 94588 Tel: (925) 462-5151 Fax: (925) 462-5183 Expires: 6/26/2014 www.cts-1.com Brian Arnold X X X Edward Bindert X X X X X Jeremy Brown X X X James Brumley X Jared Byers X X Richard Collin X X X Robert Cortez X X X X X Robert Criswell X X X Mark Dornan X X X X Tom Edwards X X X X X Tim Farley X X X X X X Gary Fechner X X X Mike Gaunt X Ron Harr X X X X Neal Hoellwarth X Richard Jones X X X X Rick Mann X X Kevin McCurdyX X Kevin Meyers X Kevin Moore X X Craig Nagle David Puskarich X X X X William Radulovich Brian Ragan X X X X X John Rink X George Rockenstein X X Larry Rothey X Erin Salazar X X Robert Schulze X Donald ShirleyX X X Tom Shuster X X X X X Larry Slater X Daryl Spieker X X Gary Stapleton X X X Matt Swope X X Travis Taylor X X Vinny Vinavong X Shawn Vucenic X John White X X X X X Isidoro Zapien X X X RC = Reinforced Concrete SW = Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W = Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpeciallnspectionList.doc revised 02101114 Agency Name, Address and expiration date Special Inspectors RC Pc Special Inspection Field SM sw HB FP S W CG Earth Systems Pacific 446 S. Hillview Dr. Milpitas, CA 95035 Tel: (408) 934-9302 Fax: (831) 637-0510 Exp: 6/28/2014 www.earthsystems.com George Barnett FP = Spray -Applied Fireproofing X X Jeff Bryan X X Norman Engen X X X X Cal Hicks X X I X X X Dennis Hurley X X rus Me'ia ENGEO Incorporated 2010 Crow Canyon PI., Suite 250 San Ramon, CA 94583 Tel: (925) 866-9000 Fax: (888) 279-2698 Exp: 7/06/2014 www.engeo.com Tim Benton Greg Hudson X Mike Huener ardt X X X X Kevin Lecce James "Chip" Moore X X X Rand Nlues X Jonathan Parker X X X X Rich Rose X X X H P Inspection, Inc. 690 Sunol ST, Building H San Jose, CA 95126 Tel: (408) 288-8460 Fax: (408) 271-0902 Expires: 11/15/2014 Larry Castrence Tony Cotta X X Mark Cotter Chuck Pinkham X X X X David Pinkham X X X X P. Scott Pinkham X X X Gary Stafford X X X X X Jason Waugh X X X X X RC = Reinforced Concrete SW = Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W = Wood SM= Structural Masonry FP = Spray -Applied Fireproofing CG = Cal Green Code SpeciallnspectionList.doc revised 02101114 Agency Name, Address and expiration date Special Inspectors RC PC Special Inspection Field SM SW HB FP s w CG Inspection Services, Inc. 1798 University Ave. Berkeley, CA 94703 Tel: (510) 900-2100 Fax: (510) 900-2101 Expires: 03/21/2015 www.inspectionservices.net Alakbarov, Ha dar CG = CalGreen Code X Amos III, Jessie X Baccus, Garrett X X Baek, Byung Gi X X X X X X Barone, Judith X X X Celik, Can X X X X X X X Colby, Paul X X Ehrsam, Gary X Falk, Andrew X X X X Flynn, Chris X X X X X X Gaut, Tobin X X X X Llames, Fernando X X X X Lon, Rand "Roy" X X X X X X Patterson, Rodger X X Putman, Edward X X X X X Sandoval, Carlos X X X X X X Shebesta, Todd X Simonton, Cy -Leon X Solis, Winnie X X Stafford, William X Stark, Douglas X X X X Toschi, Patrick X X X X X Wheeler, Steven X X X X X Kleinfelder 2601 Barrington Court Hayward, CA 94545 Tel: (925) 484-1700 Exp: 7/10/2014 www.kleinfelder.com Anderson, Tim X X X X X X Brewster, Steve X Burton, Nathan X X X Craig, Cliff X X X X X X Delabriandais, Gary X X X Eres, Mark X X X X X Foster, Stephen X X X X Hammon, Robert X X X X Johnson, Josh X Kesler, Timothy X Milla e, Leonard X X X X X Nicoletti, Johnathon X X Oandason, Jose X X X X X X Rommel, Daniel X X Saber, Sam X X X Swank, Phillip X X X RC = Reinforced Concrete SW= Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete 7 HB = High -Strength Bolding W = Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpecialInspectionList.doc revised 02/01/14 Agency Name, Address and expiration date Secial Insectors pp RC Pc Special Inspection Field SM sw HB FP s w CG Krazan & Associates, Inc. 6711 Sierra Court, Ste B Dublin, CA 94568 Tel: (925) 307-1160 Fax: (925) 307-1161 Exp: 2/6/2014 www.krazan.com James Allen X X X James Benefeito X X X Larry Borges X X X X Ron Chandler X Van DeMent X X Gregory Fernald Matthew Fernald Lewis Franklin X X X X X Ken Hafeli X X X Andy Morris X X X X Sidney Moss X X X X Matt Romero X Greqory Ruf MatriScope Engineering Laboratories, Inc. 4730 Contractors Common Livermore, CA 94551 Tel: (925) 606-7700 Fax: (925) 606-7702 Expires: 7/26/2014 www.matriscope.com D'Souza, Andrew Fannin, Dana X X X Hopelian, Joseph X X X X Keller, Don X X Kohls, Kristin Lake, Adam X X Mathis, Q. Shane X X X X X Nieser, Paul X Palmer, Scott Reese, Mark X Scoble, Kod Selvage, Kevin Shelton, James X X X X X X Sta ner, Jack X X X X X X Swartz, Jud Tadlock, K. Scott X X X X X X Tadlock, Robert X X X X X X Thomas, Chris X Varella, Joe RC = Reinforced Concrete SW= Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W = Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = Ca/Green Code SpeciallnspectionList.doc revised 02/01/14 Agency Name, Address and expiration date Special Inspectors RC Pc Special Inspection Field SM SW HB FP s w CG Neil O. Anderson & Associates, Inc. 902 Industrial Way Lodi, CA 95240 Tel: (209) 367-3701 Fax: (209) 333-8303 Expires: 2/1/2016 www.noanderson.com Allen, Eric FP = Spray -Applied Fireproofing CG = CalGreen Code Cozad, Mike X X X X X Dickey, David X Erickson, Rick Gray, Dave X X X X X X Hall, Rollin Johnson, Carl X X X X King, Ryan X Kort, Jason X X X X Landess, Frank X X X Lenehan, Gerry Me'orado, Aaron X Merrell, Ryan X Morgan, Daniel O as, George Oszut, Gregory X X X X Roberts, Jason Westfall, Kimmis X X X X X Whiting, John Williams, Roger X X X PacificlnterWest Bldg Consultants, Inc. 1600 South Main St, Suite 380 Walnut Creek, CA 94596 Tel: (925) 939-5500 Fax: (925) 939-9561 Expires: 9/6/2013 www. acificinterwest.com Cope,Doug X PSI, Inc. 365 Victor Street, Ste. C Salinas, CA 93907 Tel: (831) 757-3536 Fax: (831) 757-6265 Expires: 1/10/2015 www.psiusa.com Albert George X X X X X Deborah White X Michael Winter X X William Monger X X X X X Brand Burfield X Ezekiel Robles X Stephen Ramos X Darwin Zackary X RC = Reinforced Concrete SW = Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W = Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpeciallnspectionList.doc revised 02/01/14 Agency Name, Address and expiration date Special Inspectors RC PC Special Inspection Field SM SW HB FP S w CG RMA Group of Northern California 6296 San Ignacio Ave., Suite A San Jose, CA 95119 Tel: (408) 362-4920 Fax: (408) 362-4926 Expires: 04/01/2012 www.rmacompanies.com Alley, Maurice X CG = CalGreen Code X Bosque,Jeff X X X Carr, Greg Cecconi, Joe X Chinn, Gordon X X X X Francis, Chris X X Geraghty, Rich X X X Gillespie, John X X X X X Gundersen, Al X X X Haff, Tiffany Hughes, Dottie X X X Sondrol, Jeff X X X X Stocke, Jacob X Swain, Pat X Tellesen, Mike X X Tonkovich, Bill X X X X Walters, Chris X X X X X X Zeiher, Adam X RC = Reinforced Concrete SW = Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W= Wood SM= Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpeciallnspectionList.doc revised 02/01/14 Agency Name, Address and expiration date Special Inspectors RC PC Special Inspection Field SM SW HB FP s w CG Smith -Emery Company Corporate Office: 781 E. Washington Blvd. Los Angeles, CA 90021 Testing Facilities: 1940 Oakdale Ave. P.O. Box 880550 San Francisco, CA 94124 Tel: (415) 642-7326 Expires: 4/09/2015 www.smithemervsf.com Allder, Scott FP = Spray -Applied Fireproofing CG = CalGreen Code Brunett, John X X X Caraisco, Thomas X X X X X X Chuong,Jason X Contreras, Roberto X X X X X Cross, Len Cunningham, Jim Daniels, Jodie X X Daquinag, Bonafacio Docena, Bernard Drake, Barry X X Joakimson, Robert X X X X X X Klopson, Paul X X X Mazuk, Ray X McCarron, Liam X X X Merino, Salvador X X X X X Miranda, Allen Murphy, Mike Nadler, Joel X X X Nickerson, Scott X X X X Ross, Jason X X Serrano, Ramon Sherwood, Tony X X X X X X Starkey, Raymond Stevenson, Wylie Viramontes, Keith X X X Stevens, Ferrone & Bailey 1600 Willow Pass Court Concord, CA 94520 Tel: (925) 688-1001 Fax: (925) 688-1005 Expires: 8/09/2014 www.sfandb.com Babione, Martin X X X Conner, Scott X X X X X X Fletcher, Brett X X X X X X X Minor, Matt X X X Quinn, Tom X X X X Thielges, Jon RC = Reinforced Concrete SW = Steel & Welding S =Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W = Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpeciallnspectionList.doc revised 02/01/14 Agency Name, Address and expiration date Special Inspectors RC PC Special Inspection Field SM SW He FP s w CG Terracon Consultants, Inc. 3140 Gold Camp Drive, Suite 170 Rancho Cordova, CA 95670 Tel: (916) 858-1579 Fax: (916) 858-8277 Expires: 7/17/2015 www.terracon.com Houts, Walter X X X X X X Mears, Steven X X X X X X Testing Engineers, Inc. 2811 Teagarden Street San Leandro, CA 94577 Tel: (510) 835-3142 Fax: (510) 834-3777 Expires: 4/22/2015 testing-engineers.com Ardizonne, Mike X Dougherty, John X X X X Ganly, Jim Geraghty, Richard X X X X Grossman, Peter, P.E. X Gunderson, Al X X X X Hernandez, Frank X X X X X Mendosa, John X Muzika, Bruce X X Ronald, Seth X Souza, Jason X X Tellesen, Mike X X Thomas, Paul X X X X Watanabe, Dan X Williams, Brian X White, Walker X Yoka, John X X X Western Technologies, Inc. 3480 South Dodge Blvd. Tucson, AZ 85713 Tel: (520) 748-2262 Expires: 8/29/2014 www.wt-us.com Tiedemann, Thomas X RC = Reinforced Concrete SW = Steel & Welding S = Soils PC = Pre-stressed/Post-tensioned Concrete HB = High -Strength Bolding W = Wood SM = Structural Masonry FP = Spray -Applied Fireproofing CG = CalGreen Code SpecialInspectionList.doc revised 02101/14 FILE January 9, 2015 Albert Salvador City of Cupertino 10300 Torre Avenue Cupertino. CA95014 Re: 20450 Stevens Creek Boulevard Dear Albert, In response to your building inspector's comments Apple will comply by keeping all balcony access doors at City Center 4 floors 4 and 5 locked to prevent access. The doors are locked NN ith the Landlord key at this time and will remain so during Apple's occupancy. Apple will also work with the landlord to correct the code deficiencies that preclude us from using said balcony areas in the hopes that we will be able to utilize the areas in the future. Thank you for your consideration. Yours trul itor ea Estate & Development Apple Inc Ce: SC Builders Lease Administration Bryan Whitfield