Loading...
14090168t CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10170 MANN DR CONTRACTOR: ELITE HOME PERMIT NO: 14090168 DEVELOPMENT OWNER'S NAME: TIM CHAN 2787 MOORPARK AVE DATE ISSUED: 04/28/2015 OWNER'S PHONE: 4084161547 SAN JOSE, CA 95128 PHONE NO: (408) 838-8470 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL ADDITION TO REAR OF SFDWL 705 SQ FT, REMODEL 144 License ClassLic. # S GI SQ FT TO INCLUDE KITCHEN & BATHROOM; RE -ROOF Contractor N �� "4 Date 4% Z `� / 4 S T S7 Q I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $105000 ave and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 32619009.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save YS FR LLED INSPECT N. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Z granting of this permit. Additionally, the applicant understands and in I 3': a with all non -point source regulations per the Cupertino Municip ection 9.18. Signature Dates RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION�r '1 � 61, COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION U10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 �`� (408) 777-3228 • FAX (408) 777-3333 • buildingPcupertino.orq v AMr-7 n nc�ncin 7 /11G11 RRPTI C)RICTI.PERMIT# U NEW CONSTRUCTION I ADDITION LJ ALItR IIUry i rr u - — PROJECT ADDRESSlot-lbY, APN # I "'�%, 00 W l OWNERNAME Vv� PHO4_[,b_1SVE-MAI U / E, ZIP STREET ADDRESS CITY, STATFAX �k r��Ai A b I M . CONTACT NAME ; PHONE I E-1)4AIL Q \ �^ -� C QJ n — STREET ADDRESS CITtSTATE, ZIP FAX C`a 1017 VYI et yt V1 � OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME NUMLoAreAes BUS. LIC # _ C� LLICENSE COMPANY NAME E -MAI ` / yezjw FAX STREET ADDRESS Sg A wo CITY, .JOSE �� Y 2 a PHONE ¢4� = 3 DESCRIPTION OF WORK 2�a r f #-Aa R R ' EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES USE TYPE OCC. SQ.FT. VALUATION (S) / k / EXISTG W $3 61 NEW FLOOR DEMO TOTAL AREA NET AREA / �` L7? /� J / yO DOD /O�/ AREA Z Z AREA 10 BATHROOM RKlIckitNEMODEL _tq OTHER REMODEL '� REMODEL REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH 0 ATTACH # DWELLING UNITS: IS A SECOND UNIT ❑ YES BEING ADDED? &NO SECOND STORY ❑ YES ADDITION? Quo PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN E]YES RECEIVED BY: TOTAL VALUATION: PLANNING APPL # &NO PLANNING APPROVAL LETTER EICHLER HOME? &rNO D S O O By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this local and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable application ordinances and state laws relating to building constructi n. I authorize representatives of Cupertino to enter the above- i denti fled property for inspection purposes. Date: Z S ZZ' ( Signature of Applicant/Agent: bZ SUPPLEMENTAL INF ION REQUIRED PLAN CHECK TYPE ROUTING SLIP ❑ OVER-THE-COUNTER UIL ING PLAN REVIEW SFD or Multifamily dwellings: Apply for demolition permit for —New existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure STANDARD PUBLIC WORKS _ form if any Hazardous Materials are being used as part of this project. El LARGE FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to ❑` MAJOR SANITARY SEWER DISTRICT _ submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH B1dgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION LZrADDRESS: 10170 mann dr TYPE OF CONSTR. DATE: 09/25/2014 REVIEWED BY: Mendez APN: BP#: "'VALUATION: 1$105,000 %PERMIT TYPE: Building Permit II-B,111-B,IV,V-B PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex $1,666.00 2nd Unit? Yes No () (D PENTAMATION 1 R3SFDADD PERMIT TYPE: USE: OTC? Yes No i WORK addition to rear of sfdwl 705 sq ft remodel 144 sq ft to include kitchen & bathroom; re -roof 17 s $1,666.00 Suppl. Insp. Fee -(F) Reg. Q OT 0.0 SCOPE $0.00 OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,111-B,IV,V-B 705 $2,654.00 IR3PLNCK $1,666.00 IR3INSP $0.00 PME Plan Check: $0.00 1 1,7001 s.£ $289.00 Re -roof IREROOFRES Permit Fee: $1,666.00 Suppl. Insp. Fee -(F) Reg. Q OT 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: TOTALS: 705 $2,654.00 $1,666.00 MECH, HOURLY 0 Yes 0 No NOTE: PLUMB, HOURLY Q Yes Q No ELEC, HOURLY Q Yes Q No MISC ITEMS 1'11111117. Plan Ilian C'h". $2,654.00 Isle(' Remodel, Other 1REMRESOTII _ .., insg.). El01 0.0 ee- P1111111). 111s)�. Fee- $0.00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School M.f""t or,. Tboco foot are hacod an the nrPliminary information available and are onlv an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1%13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,654.00 = s.f. $431.00 Remodel, Other 1REMRESOTII Suppl. PC Fee: (j) Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 1 1,7001 s.£ $289.00 Re -roof IREROOFRES Permit Fee: $1,666.00 Suppl. Insp. Fee -(F) Reg. Q OT 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 1r 7'ay. E) Work Without Permit? Q Yes (F) No $0.00 Advanced Planning Fee: 1PLLONGR $98.70 Select a Non -Residential Building or Structure 0 0 Strong Motion Fee: IBSEISMICR $13.65 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $5.00 SUBTOTALS: $4,437.35 $720.00 TOTAL FEE: $5,157.35 Revised: 08/20/2014 10300 Torre Avenue Cupertino, California 95014 Telephone: (408) 777-3308 FAX: (408) 777-3333 COMMUNITY DEVELOPMENT FENCE APPROVAL (DATE) jj L,. I am an adjoining property owner of (� F l� l� (NAME) whose property is located at / r' f 7 C �tai 11 III '0r . (ADDRESS) I approve (per Section 16.28.040 of the Cupertino Municipal Code) the allowance of a foot high fence facing my property. (8 FT. MAXIMUM) SIGNED: � Name: f'� �- J /1 V Address: �C %(/-*" A— �`'� G1121/-�- G: TlanninglAppformTenMFence Approval Form.doc Updated 7/3/1007 10300 Torre Avenue Cupertino, California 95014 Telephone: (408) 777-3308 FAX: (408) 777-3333 COMMUNITY DEVELOPMENT FENCE APPROVAL Zf /Z31Lb1C (DATE) I am an adjoining property owner of (NAME) whose property is located at 1 �M �� D r (ADDRESS) I approve (per Section 16.28.040 of the Cupertino Municipal Code) the allowance of a foot high fence facing my property. (8 FT. MAXIMUM) SIGNED: d44-d�- Name: Cjls'tsf CA �p6v. � Address: U 1 ,. A U N Y) YZ G:IPlanningWppformTenceTenceApproval Form. doc Updated 7/3/2007 10300 Torre Avenue Cupertino, California 95014 Telephone: (408) 777-3308 FAX: (408) 777-3333 COMMUNITY DEVELOPMENT FENCE APPROVAL 4-2-3-2701 (DATE) I am an adjoining property owner of _ f 1 l�irl �, �•'i �1 61 (NAME) whose property is located ate �C' 116 VA (1 -k,)-( (ADDRESS) I approve (per Section 16.28.040 of the Cupertino Municipal Code) the allowance of a (8 FT. MAXIMUM) SIGNED Name: foot high fence facing my property. n Address: G: Tlanningl4ppformTencelFence Approval Form, doe Updated 7/3/2007 Permit Number14090168 Add APN _7�1E-7:1 Update Address ;10170 MANN DR Release Hold Information Event Printing Do Not Print Permit Next Reason UPDATE LOT COVERAGE CALCULATION TO F're rious Contact Info INCLUDE EAVES IN PERCENTAGE Allow Bypass Location Link Creater'Release Information Exit Created By ,ErickS ! Date V3I12I2015 W I Time •12:02 Released By 1 Date Timel r�L`F. Building Department City Of Cupertino 10300 'Fon-e Avenue Cupertino, CA 95014-3255 'l elephone: 408-777-3228 'CUPERTINO Fax: 408-777-3333 —.. _......... 4d013ADDRESS: /OCO iYJAA/ic/ _._..._..'Rlvll'rt .. _._. OWNER'S NAME: ?'ireC.y/�•v _. PHONE`L6,ssS .. i GENERAL CONTRACTOR.: �GrTE sys€ ©��•�� ov -y F-; BUSINESS LICENSE #_..................._.._.._.._._3i9/ .-APP.RIE,SS _.. ........... _ .. ':Our municipal code requires .ill businesses working in the city to have a City of Cupertino Business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTII.. THE ";ENERAI., CONTRACTOR AND ALL SUBCONTRACTORS HAVE: OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. a am not using, any subcontractors:—.. ........ ........................... ___.._. ................. .._.... -_.......... .......... .—.._........................... . Signature Date Please check applicable subcontractors an([ complete the following information: SUBCONTRACTOR BUSINIESS NAME BUSINESS LICENSE # __...-_......... ...... .... ._. -- __...... ___................. _....._....... Cabinets & Millwork j Cement Finishing ._..._._........... _.._..__—.... Electi-ical { Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass! Glazing i Ideating Insulation —_._._._._...._.._._............................__..__......._ _.._-- ....... _�_._ + Landscaping Lathing Masonry Painting / wallpaper Paving i Plastering w _ f/ Plumbing Try- { Roofing gill- Septic Tank F Sheet Metal Sheet Rock ................... _ Tile Owner / Contractor Sigmiture Date BUILDING ENERGY ANALYSIS REPORT PROJECT: Chan Addition 10170 Mann Drive Cupertino, CA 95014 Project Designer: David Wong Design 958 Meadow Drive San Jose, CA 95120 (408) 605-5335 Report Prepared by: Timothy Carstairs, CEA, HERS, GPR Carstairs Energy Calculations PO Box 4736 San Luis Obispo, CA 93403 (805) 904-9048 a CUPERTINO Job Number: Building Department �-; 14-07285 ' MAR 17 2015 REVIEWED I -OR CODE COMPLIANCE Date: Reviewed By 11^,wl 7/28/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. IThis program developed by EnergySoft, LLC — www.energysoft.com. EneTyPro 6.2 by Ener Soft User Number: 6249 ID: 14-07285 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form RMS -1 Residential Measures Summary Form MF -1 R Mandatory Measures Summary EnergyPro 62 by EnergySoft Job Number: ID: 14-07285 User Number. 6249 2 3 13 14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CF1 R -PRF -01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Residential Building 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more Special Features shown below 03 Project Location 10170 Mann Drive ENERGY USE SUMMARY 04 CA City Cupertino 05 Standards Version Compliance 2014 06 Zip code 95014 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ4 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2427 15 Number of Zones 1 16 Slab Area (FT2) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 21 Glazing Percentage (%) 114.5% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building Incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 35.11 35.50 -0.39 -1.1% Space Cooling 23.06 22.40 0.66 2.9% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 13.49 13.49 0.00 0.0% Photovoltaic Offset --- 0.00 0.00 --- TOTAL 71.66 71.39 0.27 0.4% Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at 2014-07-28T13:3S:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Non-standard roof reflectance • Window overhangs and/or fins CF1 R -PRF -01 Page 2 of 10 PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below reclure field verification by a certified HERS Rater. BUILDING FEATURE INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of tones Number of Ventilation Cooling Systems Number of Water Heating Systems Residential Building 2427 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftZ) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 1st Floor Conditioned HVAC Systema 2427 8 DHW Sys 1 Registration Number: 214-Ao071632A-000000000-0000 Registration Date/Time: 2014-09-0614:58:06 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xmi CF 1 R -PRF -01 Page 3 of 10 OPAQUE SURFACES 01 02 03 04 05 06 09 10 11 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window or Door Area (ft2 ) Tilt(deg) Status Verified Existing Condition Front Wall 1st Floor R-0 Wall 270 Front 354 76 90 Existing No Left Wall 1st Floor R-0 Wall 0 Left 264 45 90 Existing No Rear Wall 1st Floor R-0 Wall 90 Back 200 65 90 Existing No Right Wall 1st Floor R-0 Wall 180 Right 144 90 Existing No Left Wall 2 1st Floor R-15 Wail 0 Left 232 20.5 90 New N/A Rear Wall 2 1st Floor R-15 Wali 90 Back 316 89.3 90 New N/A Right Wall 2 1st Floor R-15 Wall 180 Right 152 56.02 90 New N/A Roof 1st Floor R-11 Roof Attic 1722 Existing No Roof 2 1 st Floor R-38 Roof Attic 705 New N/A Interior Surface 1st Floor»Garage R-0 Walll 236 Existing No Raised Floor 1st Floor R-0 Floor Crawlspace 1722 Existing No Raised Floor 2 1st Floor R-19 Floor Crawispace 705 New N/A Front Wall 2 Garage Garage Ext Wall 270 Front 162 90 Existing No Left Wall 3 Garage Garage Ext Wall 0 Left 262 90 Existing No Rear Wall 3 Garage Garage Ext Wali 90 Back 162 90 Existing No Right Wall 3 Garage Garage Ext Wall 180 Right 262 90 Existing No Roof 3 Garage R-0 Roof Attic 515 Existing No ATTIC 01 02 03 04 05 06 09 10 11 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condifion Attic Attic Roof Cons 0 0.1 0.85 No No Existing No Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CaICERTS inc_ CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CF1 R -PRF -01 Page 4 of 10 WINDOWS 01 02 03 04 01 02 03 04 05 06 07 08 09 10 11 Name Side of Building Width(ft ) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall --- ---- 1 6.0 0.51 0.61 Existing No Window 2 Front Wall ---- 1 16.0 0.51 0.61 Existing No Window 3 Front Wall -- -- 1 6.0 0.51 0.61 Existing No Window 4 Front Wall ---- 1 24.0 0.51 0.61 Existing No Window 5 Front Wall - 1 24.0 0.51 0.61 Existing No Window 6 Left Wail ---- 1 10.0 0.37 0.32 New N/A Window 7 Left Wall ---- 1 10.0 0.37 0.32 New N/A Window 8 Left Wail ---- --- 1 25.0 0.51 0.61 Existing No Window 9 Rear Wall - 1 12.5 0.51 0.61 Existing No Window 10 Rear Wall - 1 12.5 0.51 0.61 Existing No Window 11 Rear Wall - 1 40.0 0.51 0.61 Existing No Window 12 Left Wall 2 -- 1 4.5 0.37 0.32 New N/A Window 13 Left Wall 2 - 1 8.0 0.37 0.32 New N/A Window 14 Left Wall 2 -- --- 1 8.0 0.37 0.32 New NIA Window 15 Rear Wall 2 1 6.0 0.37 0.32 New N/A Window 16 Rear Wall 2 ---- 1 16.0 0.37 0.32 New N/A Window 17 Rear Wall 2 - 1 16.0 0.37 0.32 New N/A Window 18 Rear Wall 2 -- 1 18.0 0.37 0.32 New N/A Window 19 Rear Wall 2 -- 1 33.3 0.37 0.32 New N/A Window 20 Right Wall 2 4.0 4.0 1 16.0 0.37 0.32 New N/A Window 21 Right Wall 2 6.0 6.7 1 40.0 0.37 0.32 New N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition Door Front Wall 20.0 0.50 Existing No Door 2 Interior Surface 18.0 0.50 Existing No Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-S95c Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CF1 R -PRF -01 Page 5 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 1 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 20 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 21 2 0.1 2 2 0 0 0 0 0 1 0 0 0 0 Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-59Sc Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CFI R -PRF -01 Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 Construction Name Surface Type Framing Total Cavity R -value Assembly Layers Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation - no insulation - Attic Roof Cons Attic Roofs 2x4 Top Chord of Roof Truss @ 24 in. O.C. - no insulation - Roof Deck. Wood Siding/sheathing/decking Cavity: - no insulation - Inside Finish: - select inside finish - Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - R-0 Wall Exterior Walls 2x4 @ 16 in. O.C. no insulation (vertical) - Cavity: - no insulation (vertical) - Sheathing/Insulation: - no sheathing/insul. - Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - R-0 Roof Attic Ceilings (below attic) 2x4 @ 24 in. O.C. - no insulation - Cavity: - no insulation - SheathingInsulation - no sheathing/insul. - Inside Finish: Gypsum Board Floor Surface: Carpeted Concrete Fill., - no concrete rill - Floor Deck: Wood Siding/sheathing/decking R-0 Floor Crawlspace Floors Over Crawlspace 2x12 @ 16 in. O.C. - no insulation - Cavity: - no insulation - Sheathing/Insulation: - no sheathing/insul. - Exterior Finish: - select finish - Attic Floor. - no attic floor - R-11 Roof Attic Ceilings (below attic) 2x4 @ 24 in. O.C. R 11 Cavity: R 11 Sheathinginsulation - no sheathing/insul. - Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathing/insul. - R-0 Wall Interior Walls 2x4 @ 16 in. O.C. no insulation (vertical) - Cavity: - no insulation (vertical) - Sheathing/Insulation: - no sheathinglrnsul. - Other Side Flnish: Gypsum Board Floor Surface: Carpeted Concrete Fill: - no concrete fill - Floor Deck: Wood Siding/sheathing/decking R-19 Floor Crawlspace Floors Over Crawlspace 2x6 @ 16 in. O.C. R 19 Cavity: R 19 Sheathing/Insulation: - no sheathinghnsul. - Exterior Finish: - select finish - inside Finish: Gypsum Board Sheathing/Insulation: - no sheathinghnsul. - R-15 Wall Exterior Walls 2x4 @ 16 in. O.C. R 15 Cavity: R 15 Sheathing/Insulation: - no sheathing/insul. - Exterior Finish: Wood Siding/sheathing/decking Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CF1 R -PRF -01 Page 7 of 10 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 Attic Floor: - no attic floor - R-38 Roof Attic Ceilings (below attic) 2x4 @ 24 in. O.C. R 38 Cavity: R 38 Sheathinglnsulation - no sheathing/insul. - Verified Existing Condition NOT REQUIRED NOT REQUIRED NOT REQUIRED Inside Finish: Gypsum Board No Standard 1 Annual Inside Finish: Gypsum Board No 0.575 EF 40000-Btu/hr 0 Sheathinonsulation: - no sheathing/insul. - Garage Ext Wall Exterior Walls 2x4 @ 16 in. O.C. - no insulation (vertical) - Cavity: - no insulation (vertical) - Sheathinonsulation: - no sheathinglinsul. - Exterior Finish: 3 Coat Stucco BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation(Qll) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Verified Existing Condition NOT REQUIRED NOT REQUIRED NOT REQUIRED --- No WATER HEATING SYSTEMS 01 02 01 02 03 04 05 06 Name Distribution Type Number of Heaters Solar Fraction (%) Ststus Verified Existing Condition DHW Sys 2 Standard 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Sys 2 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 2 n/a n/a n/a n/a n/a n/a Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-07232014-595c Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CFI R -PRF -01 Page 8 of 10 HVAC SYSTEMS 01 02 01 02 03 04 05 06 07 08 09 Cooling Component 1 -hers -cool Cooling Component 1 -hers -cool Heating System Cooling System Not Required Not Required Not Required Return Duct Verify Existing HERS Name Distribution Fan Floor Area Location Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC System1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2427 Existing No None Cooling System Component 1 System Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 11.3 13 Cooling Component 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Not Required Not Required Not Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 08 Insulation Supply Duct Return Duct Verify Existing HERS Name Type Duct Leakage Rwalue Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located In Air Distribution System 1 unconditioned attic Sealed and tested 4.2 Attic Attic None Existing No System 1 -hers -dist Registration Number: 214-A0071632A-000000000.0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation DatelTime: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CF1 R -PRF -01 Page 9 of 10 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist Not Required Not Required Not Required Not Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Not Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAO Fan 0 Exhaust 0 Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:58:06 HERS Provider: CeICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at 2014-07-28T13:35:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 13:31, Mon, Jul 28, 2014 Calculation Description: Title 24 Analysis Input File Name: Chan Addition (David Wong).xml CFI R -PRF -01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: T� Timothy Carstairs Company: Signature Date: Carstairs Energy Calculations 2014-09-04 16:06:07 Address: CEA/HERS Certification Identification (If applicable): P.O. Box 4736 R08-06-210 City/State/Zip: Phone: San Luis Obispo, CA 93403 (805) 904-9048 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: ResponsibleDesigner Signature: David Wong v Company: Date Signed: David Wong Design 2014-09-06 14:58:06 Address: License: 958 Meadowood Dr NA City/State/Zip: Phone: San Jose, CA 95120 408-605-5335 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-A0071632A-000000000-0000 Registration Date/Time: 2014-09-06 14:56:06 HERS Provider: CaiCERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at 2014-07-28T33:35:34 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Chan Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/28/2014 Project Address 10170 Mann Drive Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,427 Addition 705 # of Units 1 INSULATION Construction Type Area Cavi(ft) Special Features Status Floor Wood Framed w/Crawl Space - no insulation - 1,722 Existing Wall Wood Framed - no insulation - 974 Existing Door Opaque Door - no insulation - 20 Existing Roof Wood Framed Attic R11 1,722 Existing Floor Wood Framed w/Crawl Space R 19 705 New Wall Wood Framed R 15 534 New Roof Wood Framed Attic R 38 705 New FENESTRATION I Total Area: 352 Glazing Percents 14.5 New/Altered Average U -Factor. 0.37 Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (VV) 76.0 0.510 0.61 none none Bug Screen Existing Left (N) 40.5 0.370 0.32 none none Bug Screen New Left (N) 25.0 0.510 0.61 none none Bug Screen Existing Rear (E) 65.0 0.510 0.61 none none Bug Screen Existing Rear (E) 56.0 0.370 0.32 none none Bug Screen New Rear (E) 33.3 0.370 0.32 none none Bug Screen New Right (S) 16.0 0.370 0.32 2.0 none Bug Screen New Right (S) 40.0 0.370 0.32 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnemyPro 6.2 by EnerqySoft User Number. 6249 RunCode: 2014-07-28Ti3:38:49 ID: 14-07285 Page 13 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -IR Project Name Date Chan Addition 1712812014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulabon specified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§ 1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor. 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 or equivalent U -factor. 11 Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 110.2(c). §150.00)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.2 by EnergySoft User Number. • 6249 ID: 14-07285 Page 14 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MFAR Project Name Date Chan Addition 7/28/2014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. §150.00)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air duds and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0 m 7:Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or r rammed to run only during off-peak electric demand periods. §150.0(p): Residential pool systerns orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lams rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.2 by EnergySoft User Number. 6249 /D: 14-07285 Page 15 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MFA R Project Name Date Chan Addition 1712812014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k) : Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 s uare feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or hi below, and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b_ Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.2 by EnergySoft User Number: 6249 1D: 14-07285 Page 16o