B-2016-3001 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-3001
10169 CASS PL CUPERTINO,CA 95014-2751(357 01040) FREE ENERGY
SYSTEMS INC
FOSTER CITY,CA
94404
OWNER'S NAME: KOZEN ROY K AND SYLVIA I TRUSTEE DATE ISSUED:10/27/2016
OWNER'S PHONE:408-221-7797 PHONE NO:(800)804-7958
LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO:
License Class C-46 Lic.#988918
Contractor FREE ENERGY SYSTEMS INC Date 12/31/2017 X BLDG X ELECT PLUMB
_MECH X RESIDENTIAL_COMMERCIAL
I hereby affirm that I am licensed under the provisions of Chapter 9(commencing
with Section 7000)of Division 3 of the Business&Professions Code and that my
license is in full force and effect. JOB DESCRIPTION:
(N)24 PANEL(4 ARRAYS)ROOF TOP PV SYSTEM(7.08kW);
I hereby affirm under penalty of perjury one of the following two declarations: UPGRADE MAIN PANEL(100 AMP TO 200 AMP),SAME
1. I have and will maintain a certificate of consent to self-insure for Worker's LOCATION
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. REV#1-REMOVE PANEL UPGRADE FROM SCOPE OF WORK AND
.
,�- , I have and will maintain Worker's Compensation Insurance,as provided for by ADD SUBPANEL(125 AMPS)-ISSUED 12/5/2016
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. Sq.Ft Floor Area: Valuation:$30090.00
APPLICANT CERT'IF'ICATION
I certify that I have read this application and state that the above
information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type:
and state laws relating to building construction,and hereby authorize 357 01 040
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We)agree to save indemnify and keep harmless the
City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED
may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR
Additionally,the applicant understands and will comply with all non-point
source regulations per the Cupertino Municipal Code,Section 9.18: 180 DAYS FROM LAST CALLED INSPECTION.
Signature / � Date 12/5/2016 Issued by:ABBY AY ENDE
Date:10/27/2016
OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS:
following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is
i. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for
compensation,will do the work,and the structure is not intended or offered for inspection.
sale(Sec.7044,Business&Professions Code)
2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant:
contractors to construct the project(Sec.7044,Business&Professions Code). Date:12/5/2016
I hereby affirm under penalty of perjury one of the following three declarations: •
ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1. I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE
2, I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the
Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25$05,25533,and 25534. I will
permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous
shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Mr Quality Management District I
Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Secti ns 25505,2553 #nd 5534.
Labor Code,I must forthwith comply with such provisions or this permit shall
•
be deemed revoked. C Owner or authorized agent:
APPLICANT CERTIFICATION Date:12/5/2016
I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY
correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance
relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097,Civ C.)
to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments,costs,and expenses which may accrue against said City in Lender's Address
consequence of the granting of this permit. Additionally,the applicant understands
and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION
Code,Section 9.18. I understand my plans shall be used as public records.
Licensed
Signature Date 12/5/2016 Professional
t(B1
CONSTRUCTION PERMIT APPLICATION 40
COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISIO
10300 TORRE AVENUE•CUPERTINO,CA 95014-3255
(408)777-3228•FAX(408)777-3333•buildinq(a,cupertino.orq
CUPERTINO
El NEW CONSTRUCTION 0 ADDITION ❑ ALTERATION/TI g REVISION/DEFERRED ORIGINAL PERMIT# l ) ` 4
PROJECT ADDRESS a q v [ APN# "] 0 1-®/ f )
OWNER NAME p� '1i�It PHONE _ }�A p�) ( '/Il E-MAIL /�//
C e 1' Oq •+s{ 7 —171
STREET ADDRESS fC CITY,STATE,ZIPCLI FAX
04) rt
CONTACT NAME 13,t, c
� PHONE v:Au1' Js.8,0-/5 E-MAIL
oe 4 �M y3
c°
STREET ADDRESS '-7(1),,,N. `� i CITY,STATE,ZIP kj'j C- FAX
❑'::OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT iDr-CONTRACTOR ❑CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT
CONTRACTOR NAME LICENSE NUMBER 1 LICENSE TYPE BUS.LIC#
COMPANY NAME cs E-MAIL FAX
STREET ADDRESS rr ��.. CITY,STATE,ZIP J �' PHONE
ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC#
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
DESCRIPTION OF WORK f 1/43 e1/4‘, 1NeN Y' 1 1 v1 (k..)\ 7 it r
EXISTING USE j
PROPOSED USE CONSTR.TYPE #STORIES - -
USE TYPE OCC. SQ.FT. VALUATION($)
EXISTG NEW FLOOR DEMO TOTAL
AREA AREA AREA NET AREA
BATHROOM KITCHEN OTHER - -REMODEL AREA REMODEL AREA REMODEL AREA
PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: ❑DETACH -
❑ATTACH
#DWELLING UNITS: IS.A SECOND UNIT YES SECOND STORY ❑YES
BEING ADDED? 0 N ADDITION? ONO
PRE-APPLICATION DYES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES FraxsvEIVED BY• " TOTAL VALUATION:
PLANNING APPL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO
By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to bml g construction au,f o e representatives of Cupertino to enter the abov -identified property for inspection purposes.
Signature of Applicant/Agent: - Date: A-5----
SUPPLEMENTAL
-5--SUPPLEMENTAL INFORMATION REQUIRED N" E .;r
PLAN L`I�iCIf TYPE.,„re�,,,_ y._ .,` _,;.ROT#TING SLIP
New SFD or Multifamily dwellings: Apply for demolition permit for 0,OVER`rHIE Q BUII MNGPLANREVIEW
existing building(s). Demolition permit is required prior to issuance of building
permit for new building. Ex'REss. ❑-it—AA N(pLANREvIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure a STANDARD L] PUBLIC WORICS
form if any Hazardous Materials are being used as part of this project. - I.
0'LARGE` El f REPT
Copy of Planning Approval Letter or Meeting with Planning prior to p MAJOR ❑ .SANITARY SEI3ERDISTItIUT
submittal of Building Permit application.
, a Ei4VII}ONMRNTAL HEALTH
BldgApp_2011.doc revised 06/21/11
► CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-3001
10169 CASS PL CUPERTINO,CA 95014-2751(357 01 040) FREE ENERGY
SYSTEMS INC
FOSTER CITY,CA
94404
OWNER'S NAME: KOZEN ROY KAND SYLVIA I TRUSTEE DATE ISSUED:10/27/2016
N
OWR'S PHONE:408-221-7797 PRONE NO:(800)804-7958
II
J.IC'FNSFD CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO:
Licen r a Class C46 Lic.#988918
Contr ctor FREE ENERGY SYSTEMS INC Date 12/31/2017 X BLDG X ELECT PLUMB
I hereby affirm that I am licensed under the provisions of Chapter 9(commencing —MECH X RESIDENTIAL_COMMERCIAL
with Section 7000)of Division 3 of the Business&Professions Code and that my
license is in full force and effect. JOB DESCRIPTION:
(N)24 PANEL(4 ARRAYS)ROOF TOP PV SYSTEM(7.08kW);
I hereby affirm under penalty of perjury one of the following two declarations: UPGRADE MAIN PANEL(100 AMP TO 200 AMP),SAME LOCATION
i. I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
erformance of the work for which this permit is issued.
;�I have and will maintain Worker's Compensation Insurance,as provided for by
x!► Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. Sq.Ft Floor Area: Valuation:$30090.00
APPLICANT CERTIFICATION
I certifiy that I have read this application and state that the above
information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type:
and slate laws relating to building construction,and hereby authorize 357 01 040 •
repre entatives of this city to enter upon the above mentioned property for
inspechtion purposes. (We)agree to save indemnify and keep harmless the
City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED
may accrue againstsaidCity in stands and e the comply
granting this WITHIN 180 DAYS OF PERMIT ISSUANCE OR
Additionally,the applicanfunderstands and will comply with all non-point
sourc regulations per the Cupeo' . Municipal Code,Section 9.18. 180 DAYS FROM , .. " C 1 SPECTION.
Signa ure 4_, or� Date 10/27/2016Issued by:MELI A I'
Date: 10/27/2016
OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law,for one of the RE-ROOFS:
folio g two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is
i I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for
compensation,willdo the work,and the structure is not intended or offered for inspection.
sale(Sec.7044,Business&Professions Code)
i I,as owner of the property am exclusively contracting with licensed Signature of Applicant:
contractors to construct the project(Sec.7044,Business&Professions.Code). Date:10/27/2016
I here y affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1 I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE
2 I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements ander Chapter 6.95 of the
Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will
permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
a; I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous
shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
exemption,I become subject to the Worker's Compensation provisions of the the Health&SafetyCode ections 255 i.-- a,. 2 534.
,
Labor Code,I must forthwith comply with such provisions or this permit shall !° 40.
be deemed revoked. 1� f '�
Owner or authorized agent:
APPLICANT CERTIFICATION Date:10/27/2016
I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY
correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance
relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3037,Civ C.)
to ent r upon the above mentioned property for inspection purposes. (We)agree Lender's Name
to save. indemnify and keep harmless the City of Cupertino against liabilities,
judgments,costs,and expenses which may accrue against said City in Lender's Address
consequence of the granting of this permit. Additionally,the applicant understands
and w II comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION
Code,Section 9.18. I understand my plans shall be used as public records.
Signa ure Date 10/27/2016 Licensed
Professional
_ i
tr,\ /, ALTERNATIVE ENERGY PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISIONAE
IA, 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255
UPE Nf ' (408)777-3228•FAX(408)777-3333•buildingna,cupertino.orq
4ER
ECT ADDRESS (� aJ S T} e APN# 3 9- 0 /"o d ! ' e
NAME tg e \ PHONE V rl a i 77� 1 4� ! 6
STI ET ADDRESS 10 C3k Ca-$f 7\ f CITY, STATE,ZIP f�,pmt 1 1 OIL( FAX
CONTACT NAME Br
' l T] (� i �['e� `J t P �'1 > 7�J / _f
\� PHONE 7T a L 5-- (D75 E-MAII t i o +n r ( ! tai L�i° �` C`�// co.
ST ET ADDRESS 3 pi C CITY,STATE,ZIP FAX ✓
❑ WNER 0 OWNER-BUILDER 0 OWNER AGENT 0 CONTRACTOR I CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT
COtTRACTOR NAME 4,1t .
� �� 6 LICENSE NUMBER 7 is A p LICENSE TYPE C y c BUS.LIC# ®i 4"� a p
COMPANY NAME E-MAIL ( fJ FAX `z r' /
i
111
STPEET ADDRESS ) 1 7 f®,5,s %"1 4(/0 a CITY,STATE,ZIP6✓<,kr. c'1 ?1 41 PHONE ,,
ARCHITECT/ENGINEER NAME (� (/i LICENSE NUMBER BUS.LIC#
I'
COI4PANY NAME -- E-MAIL FAX -
STPEET ADDRESS CITY,STATE,ZIP PHONE
US
13,OF SFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN
aSSTTRUCTURE: 0 Commercial URBAN INTERFACE AREA 0 Yes R No FLOOD ZONE 0 Yes No
X•s
PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTHER:
FOR SOLAR PANELS: NUMBER OF PANELS/UNITS:a Y KILOWATTS ..M O Y): - •a TOTAL VALUATION: 0 cid)
FSI. (C�
DESCRIPTION OF WORK yi 5 Ci v, 7967 �f a f S;(4,-.. - - 1 J
r. (It.rs
‘ 1' P3'' '100
By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf I have read this
appcation and the information I have provided is correct..I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to•, 'ding constructior♦. I a thorize representatives of Cupertino to enter the above-identified pr perry for inspection purposes.
,..#10. -ne-- - (./ 7
Signature of Applicant/Agent: '"s i .� Date: (� /6
SUPPLEMENTAL INFORMATION REQUIRED </ ,> ; 6
////t!
, OFFICE 1SEONLY",.
�.,.! °� oVEA THE COUNT
ER
n eL
n " E EGRESS
j/l��' _ " Jtf
D STANDARD
3?^
'LARGE.
0 MA,To
PVApp_2011.doc revised 03/16/1.1
SMOKE / CARBON MONOXIDE ALARMS
' OWNER CERTIFICATE OF COMPLIANCE
4.x.;➢teis; COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION
CUPERTINO 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255
(408)777-3228•FAX(408)777-3333•buildinq(?a cupertino.orq
s 1
f -' PI+IalyIIT CAloIN®T BE FI1�A itt TIL TATS+ ERTIFICATE IAS BEEN
y ��� � - u-
a - COMPLETED KU R +TITMIb TO ilE feinDINI WIV SYON0
PURPOSE �z
This affidavit is a self-certification for the.installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for
inspections are required.
GENERAL INFORMATION
Existing single-family and multi-family dwellings shall be provided with Smoke Alauts and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon
Monoxide Alarms be installed in the following locations: I
AREA - SMOKE ALARM CO ALARM
Outside of each separate sleeping area in the immediate vicinity of X X
the bedroom(s) _
On every level of a dwelling unit including basements X X
Within each sleeping room X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
-- Power Supply:In dwelling units with no commercial power supply, alarm(s)may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl
space.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for
alarms which must be connected to the building wiring.
1 As owner of the above-referenced property,I herebycertify that the alarm(s)referenced above has/have been °
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms specified below have been tested and are operational, as of the
date signed below.
Address: ib/t Permit No. --20(6--2ctsl1
.
Specify Number of Alarms: ] # Smoke Alarms: 'r #Carbon Monoxide Detectors:
i have read and agree to comp'with th- term: and conditions of this statement
Owner(or Owner Agent's)j� Name:
Ray' !�,!`� Signature l� Date:ioliz9 /1
Contractor Name:
Signature Lic.# Date:
Smoke and CO fbrnn.doc revised 09./27/16
WATER-CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
1.1, COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION
10300 TORRE AVENUE•CUPERTINO, CA 95014-3255
CUPERT/NO
(408)777-3228•FAX(408)777-3333•buiidino cupertino.orq
Owner Name o ff '( Permit No. - l(.( - look
Address /1/ 9 eAs., Pz 4- �c �t r�a e 957)/
1. Is your real property a registered historical site?
Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
No Go to Question 2.
2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its _
plumbing,installation of water-conserving plumbing fixtures is not technically feasible?
U Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the form and sign bottom of form.
No Go to Question 3.
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
'1% No Go to Question 4.
4. Is your realproperty built and available for use or occupancy on or before January 1, 1994?
No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
Yes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
5. Please check ONE of the following:
NI Mypropertyis asingle-family residential real property. See Civil Code Section.1101.4.
On and after January 1, 2014,building alterations or improvements shall require all non-compliant plumbing fixtures
to be replaced with water-conserving plumbing fixtures throughout the building.On or before January 1,2017,all non-
compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether
property undergoes alterations or improvements).
-0- My property is a multifamily residential real property. See Civil Code Section 1101.5.
On and after January 1,2014,specified building alterations or improvements shall require non-compliant
plumbing fixtures to be replaced with water-conserving plumbing fixtures.
On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water-
conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or
improvements).
El My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1,2014,specified building alterations or improvements shall require non-compliant
plumbing fixtures to be replaced with water-conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements).
I,as the owner or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be
replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1
through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's
installation requirements,and that the water-conserving plumbin_fixtures comply with the requirements as indicated in the
table on the following page.
4111
Owner or Owner Agent's Signature: _ ak4 4e4---11 Date:l0 nig
Upon completing and signing this Certifictlease return'<to t Building Division in order to final your building permit.
SB407 2015.doc revised 08/26/15
l ` UILDINO PERMIT CANNOT BE EINALED AND COMPLETED UNTIL THIS
, ERT1.H INANE IAS SEENSIONEDfM RETTJRTTED'TO lila IDEST DIVISION
Non-Compliant Water-Conserving Plumbing Fixture
1
Plumbing Fixture (Fixture Complying with Current Code Applicable to New Construction)
Maximum Water Usage/Flow Rate
Fixture Type 2013 CPC Ch. 4 2013 CPC Ch.4 2013 CPC Ch.4
Water Usage 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3
/Flow Rate
Single-Family Multi-Family Commercial
Residential Residential
Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush
(Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite,
average flush volume of two reduced flushes and one full flush)
Urinals Exceed 1.0
Gallons/flush 0.5 gallons/flush
Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of
gallons per minute U.S. EPA WaterSense Specification for Showerheads
(A hand-held shower is considered a showerhead.)
For multiple showerheads serving one shower,the combined flow rate of all
showerheads and/or other shower outlets controlled by a single valve shall not
exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to
allow only one shower outlet to be in operation at a time.
Faucets- Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60
Lavatory per minute • minute @ 60 psi;minimum Maximum 1.5 gallons psi
, Faucets 0.8 gallons per minute @ per minute @ 60 psi;
20 psi minimum 0.8 gallons
per minute @ 20 psi
In common and public
use areas: 0.5 gallons
per minute @ 60 psi
1.8 gallons per minute
@60 psi
Faucets- Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60
Kitchen per minute 60 psi @ 60 psi psi
Faucets May temporarily increase May temporarily
up to 2.2 gallons per increase up to 2.2
minute @ 60 psi, and must gallons per minute @
default to maximum 60 psi, and must
1.8 gallons per minute @ default to maximum
60 psi 1.8 gallons per minute
Where faucets meeting @ 60 psi
the above are unavailable, Where faucets meeting
aerators or other means the above are
may be used to achieve unavailable, aerators or
reduction. other means may be
used to achieve
• reduction.
1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown,it is not required to be upgraded.
SB407 2015.doc revised 08/26/15