Loading...
13060226I CITY OF CUPERTINO BUILDING PERMIT 1 IBUILDING ADDRESS: 21643 CASTLETON ST I CONTRAANCTOR: SHI JUN AND YANG I PERMIT NO: 13060226 OWNER'S NAME: SHI JUN AND YANG XIAOYAN 121643 CASTLETON ST I DATE ISSUED: 08/30/2013 1 I OWNER'S PHONE: 4082150683 1 CUPERTINO, CA 95014 1 PHONE NO: 1 ❑ LICENSED CONTRACTOR'S DECLARATION License Class Lic. # Contractor I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date 13)C OWNER- BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature _- " -' _ - -.""_ -- Date JOB DESCRIPTION: RESIDENTIAL C] COMMERCIAL CONSTRUCT A ONE STORY ADDITION (767 SQ FT); PANEL UPGRADE 200 AMP. REVISION #2- SWAP LAUNDRY AND BATHROOM location. ISSD OTC 3/17/2014 Sq. Ft Floor Area: I Valuation: $75000 APN Number: 35618063.00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. / Issued by: � � fZ Z i G %Date: -3 ' � 7 i -/ RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Owner or authorized agenP'-----' C��� l " Date: CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional W-1 jl CITY OF CUPERTINO BUILDING PERMIT (WILDING ADDRESS: 21643 CASTLETON ST CONTRACTOR: SHI JUN AND YANG PERMIT NO: 13060226 XIAOYAN OWNER'S NAME: SHI JUN AND YANG XIAOYAN 21643 CASTLETON ST DATE ISSUED: 08/30/2013 OWNER'S PHONE: 4082150683 CUPERTINO, CA 95014 PHONE NO: JOB DESCRIPTION: RESIDENTIAL D COMMERCIAL ❑ LICENSED CONTRACTOR'S DECLARATION CONSTRUCT A ONE STORY ADDITION (767 SQ FT); License Class Lic. # PANEL UPGRADE 200 AMP. REVISION # 1- RELOCATE MAIN ELECTRICAL PANEL & Contractor Date REVISE SIZE OF BEAM IN FAMILY ROOM - ISSUED I hereby affirm that I am licensed under the provisions of Chapter 9 1/23/2014 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $75000 I have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 35618063.00 Occupancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITIIIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM L LLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Iss Z granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section RE- ROOFS: 9.18. Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. OWNER- BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1; owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous have and will maintain a Certificate of Consent to self - insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous ompensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent - `� Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signatu� -" Date ^.2 �C CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21643 CASTLETON ST CONTRACTOR: SHI JUN AND YANG PERMIT NO: 13060226 XIAOYAN OWNER'S NAME: SHI JUN AND YANG XIAOYAN 21643 CASTLETON ST DATE ISSUED: 08/30/2013 OWNER'S PHONE: 4082150683 CUPERTINO, CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL 11 COMMERCIALII License Class Lic. # CONSTRUCT A ONE STORY ADDITION (767 SQ FT); PANEL Contractor Date UPGRADE 200 AMP. I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $75000 performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 35618063.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF P T ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FRO T LLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply Issued ate. with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE- ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. 51 OWNER- BUILDER DECLARATION Signature of Applicant: Date: 1 hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self - insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this --'— S'13v Owner or authorized agent:­ - rc-`�_Date: i2 permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature � Date - (� CUPERTINO CONSTRUCTION PERMIT APPLI T� �T COMMUNITY DEVELOPMENT DEPARTMENT • BUILDNO DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014- (408) 777 -3228 • FAX (408) 777 -3333 • building 0cuoertino.org I—I NFW CONSTRUCTION I—I ADDITION ❑ ALTERATION / TI ❑ REVISION /DEFERRED ORIGINAL PERMIT # M1 PROJECT ADDRESS' S+ 1 APN H OWNER NAME PHONE /t_ \ E -MAIL 7L i ZJ ! —:� STREET ADDRESS 1 FAX CITY, STATE, ZIP C'Ao JvI �( 1 (( � CONTACT NAME PHONE E -MAIL STREET ADDRESS CITY, STATE, ZIP FAX ❑ OWNER ❑ OWNER- BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCMTECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK �9 EXISTING USE PROPOSED USE CONITR. TYPE # STORIES I USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH # DWELLING UNITS: IS A SECOND UNIT YES SECOND STORY []YES BEING ADDED? NO ADDITION? [-]NO PRE - APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN [] YES RECEIVED BY: TOTAL VALUATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO _ Vzry By my signature below, I certify to each of the following: I am the property owner or authorized agent to act ton-re property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate: I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above - identified property for inspection purposes. Signature of ApplicandAgent --- __ __ -- - Date: 311r� c� SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP ❑ OVER -THE- COUNTER ❑ BUILDING PLAN REVIEW _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_201 I. doc revised 06121111 CUPERTINO ❑ NEW CONSTR CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISI 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • build ingacupertino.org 0 ❑ ADDITION ❑ ALTERATION / TI REVISION /DEFERRED ORIGINAL PERMIT # 194:r" 4� D C/ Sp BldgApp_201 1. doc revised 06121111 PROJECT ADDRESS i X43 C4-,s 34 APN # OWNER NAME { �,• > PHONE E-MAIL STREET ADDRESS i � ` F (•C `.J CITY, STATE, ZIP gA ej7 0 L FAX CONTACT NAME '` PHONE — ) /S —O E-MAIL STREET ADDRESS TTY, STATE, ZIP FAX D eZ 1 U ❑ OWNER ❑ OWNER - BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER F77NSE TYPE BUS. LIC # / wL E'IZ COMPANY NAME E -MAIL FAX STREET ADDRESS - CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK l,. v, / '�. ^T ^.. �✓ / �� - /6G /�✓' Z�,�� / A / n�i` Y EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA I NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA DECKIPORCH AREA GARAGE AREA: DETACH �TOTIAL []ATTACH # DWELLING UNITS: D UNIT ❑YES SECOND STORY ❑ YES BEING ADDED? ONO ADDITION? ONO PRE - APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEIVED : - TOTAL V TION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I a thorize representatives of Cupertino to enter the above - identified property' for inspection purposes. z'� ` Date: / 1 `i' Signature of Applicant/Agent: -- SUPPLEMENTAL INFORMATION REQUI PLAN CHECK TYPE ROUTING SLIP OVER-THE-COUNTER BUILDING PLAN REVIEW New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_201 1. doc revised 06121111 CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 ` (408) 777 -3228 • FAX (408) 777 -3333 • building(c-)cupertino.org CUPERTINO I / c �� g ❑ NEW CONSTRUCTION ADDITION ❑ ALTERATION / TI ❑ REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS � 43 J 1 APN # 1 � � OWNER NAME J7LA n Sh I PHONE b5o -?15-- 0683 E -MAIL soun�?r3 -6 e of �� STREET ADDRESS CITY, STATE, ZIP 4�" P'* 47 _` N V / g5-pl-f FAX CONTACT NAME �► j PHONE 6sa ++ - r I O/ 5 o K &– 5 e I �� /_ ' STREET ADDRESS >1643 � / _ CITY, STATE, ZIP FAX s OWNER ❑ OWNER - BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/EN INEER NAME Glre4r LICENSE NUMBER C 6 6 S Z BUS. LIC # g � . 064.11 COMPANY NAME c-w d es, h LL E -MAIL c h�to G of�rai /. FAX STREET ADDRESS l W CITY, STATE, ZIP /0 � r/I (�,J/� PHONE 0 ` f? DESCRIPTION OF WORK I 1 S�� / �(Q �I a J�. -L �A �[ 5 T 1 C�✓. �./> v yb lkA�",1 1J r [l�J l i" C.�!)�f B7 U✓) (A p�k Lj N) few4ka W fl.,- =N ' EXISTING USE S, PROPOSED USE CONSTR. 5 TYPE 1 # STORIES /L USE TYPE OCC. SQ.FT. VALUATION (S) 2 S EXISTG NEW FLOOR DEMO TOTAL AREA / 151 G AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA n 3 !Q PORCH AREA 176 DECK AREA --Y6' TOTAL DECK/PORCH AREA 3 6 GARAGE AREA: DETACH 46 2 potTTACH # DWELLING UNITS: IS A SECOND UNTT YES SECOND STORY ❑ YES BEING ADDED? ZNO ADDITION? NO PRE - APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEI D, BY: TOTAL VALUATION: PLANNING APPL # NO PLANNING APPROVAL LETTER EICHLER HOME? IR NO j`Oo O By my signature below, I certify to each of the following: I am the property owner or authori d a fit to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work andKerify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. , �~ id Signature of Applicant/Agent: _Z:Z: —� Date: SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP ❑ OVER - THE - COUNTER BRLDING PLAN REVIEW _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS PLANNING PLAN .REVIEW '. _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure A.'`'DARD PUBLICWORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ vlAaoR _ER submittal of Building Permit application. sAN1TAiY DISTRICT ❑' ENVIRONMENTAL HEALTH....J BldgApp_2011.doc revised 06121111 FM__7 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION 10, ADDRESS: 21643 castieton st DATE: 03/17/2014 REVIEWED BY: mendez MISC ITEMS APN: BP #: 13060226 'VALUATION: $500 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY USE: SFD or Duplex hrs PENTAMATION PERMIT TYPE: 1 GENRE WORK REVISION #2- SWAP LAUNDRY AND BATHROOM. ISSD OTC 3/17/2014 SCOPE -- – —� FT LL] NOTE: This estimate does not include fees due to other Departments (i. e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'1 info. FEE ITEMS (Fee Resolution 11 -053 Eff ''1%13) FEE QTY/FEE MISC ITEMS Plan Check Fee: Hourly Only? 0 Yes 0 No $0.00 1 1 hours Plan Check, Hourly $139.00 1STPLNCK Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee.S Reg. © OT 0,0 Iirs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 irri rrrn. t E: 0 0 Work Without Permit? 0 Yes E) No $0.00 Advanced Planning Fee. $0.00 Select a Non - Residential Building or Structure 0 ;,rm el Documentation Fees: Strong Motion Fee: 1BSEISMICR $0.50 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $1.50 $139.00 TOTAL FEE: $140.50 Revised: 01/15/2014 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School n. *- . -:... ,..,. TL...... 1­ - A—ad „„ tho nroli.ninanr infortaatintt availahle and are onlv an estimate. Contact the Dent for addn7 info. FEE ITEMS (Fee Resolution 11 -053 Ef1.' 71 113) DDRESS: 21643 CASTLETON ST DATE: 01/23/2014 REVIEWED BY: MELISSA W PN: 356 18 063 BP #: 13060226 `VALUATION: $0 PE: Building Permit =PLAN TYPE: Alteration /Repair PRIMARY SFD or Duplex $0.00 PENTAMATION 1GENRES PERMIT TYPE: i USE: $0.00 Suppl. Insp. Fee:Q Reg. Q OT WORK REVISION # 1 - RELOCATE MAIN ELECTRICAL PANEL & REVISE SIZE OF BEAM IN FAMILY SCOPE I ROOM - ISSUED 1/23/2014 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School n. *- . -:... ,..,. TL...... 1­ - A—ad „„ tho nroli.ninanr infortaatintt availahle and are onlv an estimate. Contact the Dent for addn7 info. FEE ITEMS (Fee Resolution 11 -053 Ef1.' 71 113) FEE QTY /FEE Mech. P 11 1 hu>,' . _ . Fee. P<v grit t...,, Other Alech. Insp. 01her Plumb Insp. 01irer Elec. Insp. Alech. Insp. Fee: P /urnb. Insp. $0.00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School n. *- . -:... ,..,. TL...... 1­ - A—ad „„ tho nroli.ninanr infortaatintt availahle and are onlv an estimate. Contact the Dent for addn7 info. FEE ITEMS (Fee Resolution 11 -053 Ef1.' 71 113) FEE QTY /FEE MISC ITEMS Plan Check Fee: Hourly Only? 0 Yes Q No $0.00 F7 hours Plan Check, Hourly $139.00 1STPLNCK Suppl. PC Fee: Q Reg. Q OT 0.0 1 firs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 0,0 firs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Conswuction .Tax. T_T_ Adinhiistrative Fee: o E) Work Without Permit? © Yes (F) No $0.00 Advanced Planning-Lee.- $0.00 Select a Non - Residential Building or Structure i Travel Documentation Fees: Strong Motion Fee: $0.00 Select an Administrative Item Bldw Stds Commission Fee: $0.00 SUBTOTALS: $0.00 $139.00 TOTAL FEE: $139.00 Revised: 01/15/2014 CITY OF CUPERTINO ra-w-f7w FFF. F.CTIMATOR - BUILDING DIVISION 191 ADDRESS: 21643 castleton St' DATE: 06/2812013 REVIEWED BY: mendez PC FEE ID APN: BP #: 'VALUATION: $75,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: 2nd Unit? 0 Yes No OTC? ® Yes (j) No PENTAMATION 1 R3SFDADD PERMIT TYPE: i WORK 1st story addition of 767 sq ft to include living, lobby, porch and bathroom panel upgrade 200 am SCOPE OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R -3 (Custom) II- B,III- l3JV,V -B 767 $2,468.00 1R3PLNCK $1,549.00 1R3INSP I;lec- Insp. $0.00 Permit Fee: $1,549.00 Suppl. Insp. Fee-0 Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $45.00 TOTALS: 767 $2,468.00 $1,549.00 MECH, HOURLY Q Yes 0 No PLUMB, HOURLY Q Yes E) No ELEC, HOURLY Q Yes Q No MISC ITEMS Elec. Plan Check 0.0 hrs $0.00 Lti>ch. Permit Fee. 'lump. Pei ~mi[ %'ee: Elec. Permit Fee: IEPERMIT !hher Meek Insp. Other I'iurni, Insp. Other Elea Insp. 0.0 hrs $45.00 Vech. Insp. Fee: Phtrnh. Insp. Fee: I;lec- Insp. NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Worlts, tire, aanitary, ewer utstrict acnoot n h"e-1 nn A. nratiminnnr infnrmntinn availahle and are only an estimate. Contact the Dent for addn'l info. FEE ITEMS (Tee Resolution 11 -053 Ef 711112) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,468.00 F200 amps Electrical $45.00 IBELEC200 Services Suppl. PC Fee: Q Reg, Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $1,549.00 Suppl. Insp. Fee-0 Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $45.00 C`onstructivn .Tar: Administrative .Fee: O 0 Work Without Permit? ® Yes (j) No $0.00 Advanced Planning Fee: IPLLONGR $99.71 Select a Non - Residential Building or Structure 0 Q i Travel Documentation Fee: 1TR4VDOC $45.00 Strong Motion Fee: IBSEISMICR $7.50 Select an Administrative Item - Bld Stds Commission Fee: IBCBSC $3.00 SUBTOTALS: $4,217.21 $45.00 TOTAL FEE: $4,262.21 Revised: 04/29/2013 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014 -3255 Telephone: 408 - 777 -3228 C U P E RT I N O Fax: 408 - 777 -3333 CONTRACTOR / SUBCONTRACTOR LIST JOB ADDRESS: ,11 :5 PERMIT # 13 O DL-2- OWNER'S NAME: PHONE # — -- 62 6 GENERAL CONTRACTOR: BUSINESS LICENSE # ADDRESS: CITY /ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Please check applicable subcontractors and complete the following information: Date t/ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Y4 6L Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving ` Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner / Contractor Signature — Date 7y� CUPERTINO CONTRACTOR / SUBCONTRACTOR LIST Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014 -3255 Telephone: 408 - 777 -3228 Fax: 408- 777 -3333 JOB ADDRESS: !7)_l 6 PERMIT # 13066 Z OWNER'S NAME: PHONE # —0 — D- 1,S— ©6 GENERAL CONTRACTOR: BUSINESS LICENSE # ADDRESS: CITY /ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTIONS) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Please check applicable subcontractors and complete the following information: Date Owner / Contractor Date SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner / Contractor Date 1 OWNER- BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • building(d)cupertino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS .a' AP 3 13-06,3 BP# ,L OWNER NAME OWNER ADDRE S g DESCRIPTION OF WORK: ,WA We are providing you with an Owner - Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner - Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) -M1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner - Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner - Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 7S 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. M3. 1 understand as an "Owner- Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. J4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. U_'�_5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer' under state and federal law. US 6. 1 understand if I am considered an "employer' under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. J-S 7. 1 understand under California Contractors' State License Law, an Owner - Builder who builds single - family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 758. 1 understand as an Owner - Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. amerBuilderForm 2010.doc revised 04114110 ya9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800 - 321 -CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. I—S-10. I am aware of and consent to an Owner - Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. _ 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner - Builders as well as employers. a12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to. assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner - Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS: Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: —c Date: ---- - - - - -- - - - - - - - ---------- - - - - -- - - ------------------------------ --------------- - (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner - Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner - Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out.the above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: OwnerBuilderForm 2010.doc revised 04 114110 BUILDING ENERGY ANALYSIS REPORT I 1.30 100�3� PROJECT: Mr. Shi Residence Remodel 21643 Castleton St. Cupertino, CA 95014 -4712 Project Designer: W H Y Construction 6805 Westmoor Way San Jose, CA 95129 1- 408 - 218 -0587 ,. 'A CUP�n Suildi D�= ng Do . _. , ur�z,.;. AUG 10 2013 Report Prepared by; ;_`��r� �oR copE Jack Lin COMPLIAar(,- r'�vidv� 8 - W H Y Construction y 6805 Westmoor Way San Jose, CA 95129 1- 408 - 218 -0587 Job Number: WHY13 -0314 Date: 6/28/2013 SUBMITTAL #1 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013- 06- 28T01:52:51 /D: WHY13 -0314 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. Shi Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition /Alteration Date 612812013 Project Address 21643 Castleton St. Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,881 Addition 767 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST • Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. • Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft`) Features (see Part 2 of 5) Status Wall Wood Framed R -13 1,488 Existing Wall Wood Framed R -13 1,026 Altered Door Opaque Door None 101 Existing Floor Wood Framed w /Crawl Space R -19 2,114 Existing Roof Wood Framed Attic R -30 1,367 Existing Wall Wood Framed R -13 408 New Door Opaque Door None 73 New Floor Wood Framed w /Crawl Space R -19 767 New FENESTRATION U- Exterior Orientation Area(ft`) Factor SHGC Overhang Sidefins Shades Status Left (lM 21.0 0.550 0.67 2.0 none Roll -down Blind or Slats Existing Right (E) 80.0 0.370 0.32 2.0 none Roll -down Blind or Slats New Rear (N) 58.0 0.370 0.32 2.0 none Roll -down Blind or Slats New Front (S) 112.0 0.370 0.32 2.0 none Roll -down Blind or Slats New Front (S) 33.0 0.550 0.67 2.0 none Roll -down Blind or Slats Existing Right (E) 7.3 0.550 0.67 2.0 none Roll -down Blind or Slats Existing Rear (N) 18.0 0.550 0.67 2.0 none Roll -down Blind or Slats Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 96% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Res HVAC Ducted Ducted Garage 6.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 60 0.62 No Pipe Insulation New EnergyPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013 -06- 28701:52:51 ID: WHY13 -0314 Page 2 of 12 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. Shi Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition /Alteration Date 612812013 Project Address 21643 Castleton St. Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2, 881 Addition 767 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST • Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. • Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft`) Features (see Part 2 of 5) Status Roof Wood Framed Attic R -30 767 New FENESTRATION U- Exterior Orientation Area(ft`) Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013 -06- 28701:52:51 ID: WHY13 -0314 Page 3 of 12 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mr. Shi Residence Remodel Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition /Alteration Date 612812013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and /or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnergyPro 5.1 by EnergySoft User Number: 20692 Run Code: 2013- 06- 28T01:52:51 ID: WHY13 -0314 Pa e 4 of 12 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. Shi Residence Remodel ❑ Multi Family m Existing+ Addition /Alteration 612812013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV (kBtu /ft2- r) Space Heating 27.38 23.64 3.74 Space Cooling 2.02 0.97 1.06 Fans 3.96 3.90 0.07 Domestic Hot Water 13.71 12.99 0.73 Pumps 0.00 0.00 0.00 Totals 47.08 41.49 5.59 Percent Better Than Standard: 11.9 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls /Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 1,050 145 Fuel Available at Site: Natural Gas (W) 636 21 Raised Floor Area: 2,881 (N) 1,068 76 Slab on Grade Area: 0 (E) 671 87 Average Ceiling Height: 8.5 Roof 2,134 0 Fenestration Average U- Factor: 0.41 TOTAL: 329 Average SHGC: 0.40 Fenestration /CFA Ratio: 11.4 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company W H Y Construction -oz pL— 612812013 Address 6805 Westmoor Way Name Jack Lin City/State/Zip City/State/Zip San Jose, CA 95129 Phone 1-408- 218 -0587 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) /f / W H Y Construction Company 6805 Westmoor Way Jack Lin (/ Address Name C414 q041V City /State /Zip San Jose, CA 95129 Phone 1-408- 218 -0587 Signed License # Date EnerqyPro 5.1 by EnerqySoft User Number: 20692 RunCode: 2013- 06- 28T01:52:51 ID: WHY13 -0314 Page 5 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. Shi Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition /Alteration Date 612812013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location /Comments Cavity Exterior Frame Interior Frame Wall 190 0.102 R -13 270 90 Existing 4.3.1 -A3 1st Floor Wall 469 0.102 R -13 180 90 Altered 4.3.1 -A3 (E= 4.3.1 -A3) 1st Floor Wall 179 0.102 R -13 90 90 Existing 14.3. 1 -A3 1st Floor Wall 327 0.102 R -13 01 90 Existing 14.3. 1 -A3 1st Floor Door 511 0.500 None 1 0 90 Existing 4.5.1 -A4 1st Floor Door 51 0.500 None 0 90 Existing 4.5.1 -A4 1st Floor Floor 1,357 0.037 R -19 0 180 Existing 4.4.1 -A4 1st Floor Roof 632 0.031 R -30 180 18 Existing 4.2.1 -A20 1st Floor Wall 206 0.102 R -13 180 90 New 4.3.1 -A3 1st Floor Door 40 0.500 None 180 90 New 4.5.1 -A4 1st Floor Wall 359 0.102 R -13 0 90 Altered 4.3.1 -A3 (E= 4.3.1 -A3) 1st Floor Door 17 0.500 None 0 90 New 4.5.1 -A4 1st Floor Wall 202 0.102 R -13 90 90 New 4.3.1 -A3 1st Floor Floor 767 0.037 R -19 0 180 New 4.4.1 -A4 1st Floor Roof 767 0.031 R -30 180 18, New 4.2.1 -A20 1st Floor Wall 198 0.102 R -13 2701 90 1 Altered 14.3. 1 -A3(E= 4.3.1 -A3) 1st Floor FENESTRATION SURFACE DETAILS ID Type Area U- Factor SHGC2 Azm Status Glazing Type Location /Comments 1 Window 21.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear 1st Floor 2 Window 32.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vinyl /Low -E 1st Floor 3 Window 24.0 0.370 NFRC 0.32 NFRC 0 New IWC 5300 VinyULow -E 1st Floor 4 Window 16.0 0.370 NFRC 0.32 NFRC 0 New IWC 5300 VinyULow -E 1st Floor 5 Window 16.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyULow -E 1st Floor 6 Window 48.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyULow -E 1st Floor 7 Window 48.0 0.370 NFRC 0.32 1 NFRC 180 New IWC 5300 VinyULow -E 1st Floor 8 Window 24.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 VinyULow -E 1st Floor 9 Window 24.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 VinyULow -E 1st Floor 10 Window 24.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear 2nd Floor 11 Window 9.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear 2nd Floor 12 Window 6.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear 2nd Floor 13 Window 1.3 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear 2nd Floor 14 Window 18.0 0.370 NFRC 0.32 NFRC 0 New IWC 5300 VinyULow -E 2nd Floor 15 lWindow 18.0 0. 5501 Default 0.67 Default 0 Existing Double Non Metal Clear 2nd Floor (1) U- Factor Type: 116 -A = Default Table from Standards, NFRC = Labeled Value (2 ) SHGC Type: 116 -B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 3.51 6.0 2.0 0.1 2.0 2.0 2 Roll -down Blind or Slats 0.13 4.0 8.0 2.0 0.1 2.0 2.0 3 Roll -down Blind or Slats 0.13 4.0 6.0 2.0 0.1 2.0 2.0 4 Roll -down Blind or Slats 0.13 4.0 4.0 2.0 0.1 2.0 2.0 5 Roll -down Blind or Slats 0.13 4.0 4.0 2.0 0.1 2.0 2.0 6 Roll -down Blind or Slats 0.13 6.0 8.01 2.0 0.1 2.0 2.0 7 Roll -down Blind or Slats 0.13 6.0 8.0 2.0 0.1 2.0 2.0 8 Roll -down Blind or Slats 0.13 8.0 3.0 2.0 0.1 2.0 2.0 9 Roll -down Blind or Slats 0.13 8.0 3.0 2.0 0.1 2.0 2.0 10 Roll -down Blind or Slats 0.13 3.0 8.0 2.0 0.1 2.0 2.0 11 Roll -down Blind or Slats 0.13 3.0 3.0 2.0 0.1 2.01 2.0 12 Roll -down Blind or Slats 0.13 2.0 3.0 2.0 0.1 2.0 2.0 13 Roll -down Blind or Slats 0.13 1.0 1.3 2.01 0.1 2.0 2.0 14 Roll -down Blind or Slats 0.13 3.0 6.0 2.0 0.1 2.0 2.0 15 Roll -down Blind or Slats 0.13 3.0 6.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013 -06- 28701:52:51 ID: WHY13 -0314 Page 6 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. Shi Residence Remodel Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition /Alteration Date 612812013 OPAQUE SURFACE DETAILS Surface Typ e Area U- I Factor Insulation Azm Tilt Status Joint Appendix 4 Location /Comments Cavity Exterior Frame Interior Frame Door 171 0.500 None 270 90 New 4.5.1 -A4 1st Floor Wall 211 0.102 R -13 270 90 Existing 4.3.1 -A3 2nd Floor Wall 191 0.102 R -13 180 90 Existing 14.3. 1 -A3 2nd Floor Wall 203 0.102 R -13 901 90 Existing 4.3.1 -A3 2nd Floor Wall 188 0.102 R -13 0 90 Existing 4.3.1 -A3 2nd Floor Floor 757 0.037 R -19 0 180 Existing 4.4.1 -A4 2nd Floor Roof 735 0.031 R -30 180 18 Existing 4.2.1 -A20 2nd Floor FENESTRATION SURFACE DETAILS ID Type Area U- Factor SHGC2 Azm Status Glazing Type Location /Comments (1) U- Factor Type: 116 -A = Default Table from Standards, NFRC = Labeled Value (2) SHGC Type: 116 -B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t EnergyPro 5.1 by EnergySoft User Number: 20692 Run Code: 2013- 06- 28T01:52:51 ID: WHY13 -0314 Page 7 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. Shi Residence Remodel Building Type © Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition /Alteration Date 612812013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existing Altered Removed Res HVAC Existing 1st floor 1,357 10,856 1966 New 1st floor 767 7,670 Existing 2nd floor 757 6,056 1966 Totals 7671 2,114 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Res HVAC 1 Central Furnace 96 % AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Coolin Duct Location Duct R -Value Ducts Tested? Status Res HVAC Ducted Ducted Garage 6.0 ❑ New El WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Rheem 6G60PV55FW 1 Small Gas No Pipe Insulation 55,000 60 0.62 n/a n/a New MULTI - FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft)a 0 c Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried Ener yPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013 -06- 28701:52:51 ID: WHY13 -0314 Page 8 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name Mr. Shi Residence Remodel Date 612812013 NOTE: Low -rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF- 1 R -ALT Form) shall supersede the items marked with an asterisk ( *) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field- fabricated windows) have a label listing the certified U- Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10 -111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50(a): Minimum R -19 insulation in wood -frame ceiling orequivalent U- factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R- Value. *§1 50(c): Minimum R -13 insulation in wood -frame wall orequivalent U- factor. *§1 50(d): Minimum R -13 insulation in raised wood -frame floor orequivalent U- factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677 -95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3 %; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110- §113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §1 13(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu /hr are exempt), and pool and spa heaters. 150(h): Heating and /or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R -12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water - heating system, or other indirect hot water tanks have R -12 external insulation or R -16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non - recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150 -B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150 -B and Equation 150 -A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123 -A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water-heating systems and /or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013- 06- 28T01:52:51 ID: WHY13 -0314 Page 9,f MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. Shi Residence Remodel 1612812013 §150(m)1: All air - distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6 -5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct - closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross - sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI /ASHRAE Standard 62.2 -2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 (b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150( ): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §1 50( . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150 -C and is not a low efficacy luminaire asspecified by 150 k 2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by 130 d . §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150 -C and shall not contain a line- voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §1 50(k). 150(k)7: All switching devices and controls shall meet the requirements of §1 50(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (FMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013- 06 -28T01 :52:51 ID: WHY13 -0314 Page 10 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr. Shi Residence Remodel 612812013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §1 50 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing /rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low -rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on /off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to § 1 30 d . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non - dwelling spaces of low -rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 20692 RunCode: 2013 -06- 28701:52:51 ID: WHY13 -0314 Page 11 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. Shi Residence Remodel Date 6/28/2013 System Name Res HVAC Floor Area 2,881 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 575 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 38,000 12,332 1,603 957 37,297 Total Output (Btuh) 38,000 0 Output (Btuh /s ft ) 13.2 159 1,252 Cooling System 0 0 Output per System 25,000 0 OF 0 0 Total Output (Btuh) 25,000 0 1,603 0 Total Output (Tons) 2.1 159 1,252 Total Output (Btuh /sqft) 8.7 Total Output s ft/Ton) 1,382.9 1 12,650 39,801 Air System CFM per System 895 HVAC EQUIPMENT SELECTION Airflow (cfm ) 895 Bryant 556AN024- E/350MAV024040 18,059 5,665 38,000 Airflow (cfm /s ft) 0.31 Airflow (cfm/Ton) 429.6 Outside Air ( %) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 18,059 5,665 38,000 Jan 1 AM Outside Air (cfm /sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 28 OF 67 IF 67 OF ;05 ` Outside Air Ar 0 cfm Supply Fan Heating Coil 895 cfm 67 OF 4 A 4 104 °F R OM 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 88 / 68 OF 7!,.'32 Outside Air 0 cfm AL 75x'62 'IF IF 75 / 61 OF 55 / 54 OF a �= Supply Fan Cooling Coil 55 / 54 OF 895 cfm pp 46.7% ROOM 75 62 n EnergyPro 5.1 by EnergySoft User Number., 20692 RunCode: 2013 -06- 28701:52:51 ID: WHY13 -0314 Page 12 of 12