Loading...
14120008S,' CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20849 GREENLEAF DR CONTRACTOR: SIMON ZHANG PERMIT NO: 14120008 OWNER'S NAME: HUANG XIANGDONG AND ZHANG XIAOYI 18488 PROSPECT RD DATE ISSUED: 05/28/2015 OWNER'S PHONE: 4083327690 SARATOGA, CA 95070 PHONE NO: (408) 887 -0591 fu / LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL ❑ REMOVE (E) ACCESSORY SHED AND CONSTRUCT (N) 1 License Class_ Li #/1,. STORY 2ND UNIT WITH 1,261 S.F (2 BEDROOMS /1 BATH) Contractor. I hereby affirm that I am licensed under to provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $230000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by b'ection 3700 of the Labor Code, for the performance of the work for which this APN Number: 32609007.20849 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 D R MIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 D AST C SPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the ate: granting of this permit. Additionally, the applicant understands and will comply s with all non -point source regulations per the Cupertino Municipal Cod Sectio RE- ROOFS: 9.18. Signature e k/ All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER- BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self - insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. �u Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: C Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date Ve • CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ` V 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 ` (408) 777 -3228 •FAX (408) 777 -3333 • building a(�cupertino. or q O NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT #t PROJECT ADDRESS Jtq + APN k OWNERNAME I PHONE 7- 6 X 'Cly U /V E -MAIL J �L4(A l (� �- Mary , STREET ADDRESS CITY, STATE, ZIP IA 7 /' CA FAX P7 2014 (� CONTACT NAME PH%o / _ (� ➢i (Q E -MAIL STREET ADDRES CITY, STATE, ZIP r� FAX 2 - C �\ 1-G- H O U �G� ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT ❑ OWNER 1:3 OWNER- BUILDER ❑ OWNER AGENT El CONTRACTOR 13 CONTRACTOR AGENT b<_ CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC k COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE CHrrECT NGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK - `e Provo, 4- S Y h EXISTING USE PROPOSED USE CONSTR TYPE #STORIES 'n r¢- Y) �J V I USE TYPE OCC. SQ.FT. VALUATION (S) EXISTG AREA % j _ !(J NEW FLOOR AREA / I DEMO AREA �2 2 /� / TOTAL NET AREA �(p �I C B� C V v1 0 BATHROOM REMODEL AREA KITCHEN REMODEL AREA OTHER REMODEL AREA ll.. PORCH AREA DECK AREA TOTAL DECKIPORCH AREA GARAGE AREA: DETACH (, ❑ ATIACH 9DWELLINGUNI'I'S: ISA SECOND UNrrc� ❑YES SECOND TORY E] YES BEING ADDED? ❑NO ADDITION? ❑NO PRE - APPLICATION ❑YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑YES TOTALVALUATION: PLANNING APPLX NO PLANNING APPROVAL LETTER EICHLER HOME? FIND By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the opA owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accur I agree to comply with all applicable local ordinances and state laws relating to ildi g construction. I autho .ze representatives of Cupertino to enter the above - identified property for inspection purposes. C 1 Signature of Applicant/Agent: Date: C 2^ SUPPLEMENTAL 0RMAT1CM_REQbfT1SD PLAN cPrECiT��E ...u_.. Y . RouTUac silr Q OVER THE COUNTER s' ❑ BUILDING PLAN REVIEW New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition per is required prior to issuance of building * a permit for new building. ❑ {EXPRESS 4 e ❑ PLANI\II\G PLAN REVIEW e vp 1 Yu Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ sTAnnnRD ❑ PvBLICwoRxs ' form if any Hazardous Materials are being used as part of this project. a3 ❑ LARGE w FZRE DEPT Copy of Planning Approval Letter or Meeting With Planning prior to p ❑' _ submittal of Building Permit application. IvlArox sAnITAIiY SEwER:I)ISTRICT: .' . ❑ +•ENVIROIVfiIENTALIHEALTFi. , BldgApp_2011.doc revised 06121111 "'I, CITY OF CUPERTINO 10 oiAVIO FFF. FRTIMATOR —BUILDING DIVISION OCCUPANCY TYPE: ADDRESS: 208441GREENLEAF DR DATE: 12/02/2014 REVIEWED BY: MELISSA PC FEE ID APN: 326 09 007 BP #: VALUATION: $230,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: New Construction PRIMARY USE: SFD or Duplex 2nd Unit? '' Yes 0 No PENTAMATION 1 R3SFD2ND PERMIT TYPE: WORK I REMOVE E ACCESSORY SHED 336 S.F. CONSTRUCT N 1 STORY 2ND UNIT WITH 1,261 S.F SCOPE (2 BEDROOMS /1 BATH) OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA S. PC FEES PC FEE ID BP FEES BP FEE ID R -3 (Custom) II- B,III- B,IV,V -B 1,261 $2,715.89 IR3PLNCK $1,887.73 IR3INSP $0.00 PME Plan Check: $0.00 Permit Fee: $1,887.73 Suppl. Insp. Fee:O Reg. 0 OT 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 TOTALS: 1,261 $2,715.89 Construction Tax: 1BCONSTAXR 1 $1,887.73 # new NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, Schoot nictrirt erc ) The.ce fees are hated nn the nreliminary information available and are onlv an estimate. Contact the Dept for adda'l info. FEE ITEMS (Fee Resolution 11 -053 Ef ' 711113) t fech, Man "heck 1'1111rrh. Plum C. he('% Check mech. P2rutit F e I'lerxzh. Fevinit " ;,ee: h7vc. Per)Wf Fce. Ofhcr ,t loch. Irrsp !other Pi11;nb /VuP3 Usher Ins"', i ?e. P /21n1b. hisp. /.ev. Elec. InS17. 1`;?O: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, Schoot nictrirt erc ) The.ce fees are hated nn the nreliminary information available and are onlv an estimate. Contact the Dept for adda'l info. FEE ITEMS (Fee Resolution 11 -053 Ef ' 711113) FEE QTY /FEE MISC ITEMS Plan Check Fee: $2,715.89 Select a Misc Bldg/Structure or Element of a Building i Suppl. PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $1,887.73 Suppl. Insp. Fee:O Reg. 0 OT 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: 1BCONSTAXR Filunits # new $ 667.73 _ 2. irninistr ati t a Fee: 0 0 Work Without Permit? 0 Yes C• No $0.00 Advanced Planning Fee: IPLLONGR $176.54 Select a Non - Residential Building or Structure 0 0 7i�cr��r'l C7r >r, urrr.arata,'iu,t IE7�>. >: Strong Motion Fee: IBSEISMICR $29.90 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $10.00 SUBTOTALS: $5,487.791 $0.00 ° TOTAL FEE-T $5,487.79 Revised: 10/01/2014 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014 -3255 Telephone: 408 - 777 -3228 C U P E RT I N O Fax: 408 - 777 -3333 CONTRACTOR / SUBCONTRACTOR LIST JOB ADDRESS: zo 8 ,r�.� PERMIT # X6)00 OWNER'S NAME: 414 &44 ` IT14 PHONE # 'C GENERAL CONTRACTOR: BUSINESS LICENSE # ADDRESS: CITY /ZIPCODE: f *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: o/ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical ELEC-J ICAL Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating L' I-i J� � Gvn i CC;,( h C_ Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Ay' A2L /xic . -?0oo �? Tile Owner / Contractor Signature Dat BUILDING ENERGY ANALYSIS REPORT 04 OT PROJECT: SINGLE HOUSE 2ND UNIT 20847 GREENLEAF CUPERTINO, CA 95014 Project Designer: H.M.C. ASSOCIATES, LLP. 12280 SARATOGA SUNNYVALE RD. #209 SARATOGA, CA 95070 ()408)446 -8418 Report Prepared by: ECEI ' E- PERFECT DESIGN & DEVELOPMENT, INC. C 2, 2914 BY Job Number: P14-7280 Date: 10/8/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. User 0 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form RMS -1 Residential Measures Summary Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro 6.3 by EnergySoft Job Number: ID: P14- -7280 User Number: 1919 1 2 3 10 11 14 15 16 17 FENESTRATION Orientation Area(ft) I Total Area: 103 Glazinq Percentage: 12.9% U -Fac SHGC Overhang Sidefins New /Altered Average U- Factor: Exterior Shades 0.30 Status Left (Kq 0.0 0.300 0.21 none none Bug Screen New Right (E) 8.0 0.300 0.21 none none Bug Screen New Rear (N) 36.0 0.300 0.21 none none Bug Screen New Front (S) 59.0 0.300 0.21 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status WHOLE HOUSE Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Instantaneous Gas 0 0.84 Recirc/Demand Motion New [Ene:m�yPro 6.3 6 Ene Soft User Number. 1919 RunCode: 2 0 14 -10- 08 715:24:38 ID: P14 -7280 Page 10 of J7 MANDATORY MEASURES SUMMARY: Residential Page 1 of 3 MF -1 R Project Name Date SINGLE HOUSE 2ND UNIT 1101812014 NOTE: Low -rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF- 1 R -ALT Form) shall supersede the items marked with an asterisk ( *) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. -Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field - fabricated windows) have a label listing the certified U- Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10 -111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 11 0.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150.0(a): Minimum R -30 R -19 for Additions /Alterations insulation in wood -frame ceiling orequivalent U- factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R- Value. *§150.0(c): Minimum R -13 insulation in 2x4 wood -frame wall (R -19 in 2x6) orequivalent U- factor. *§150.0(d): Minimum R -19 insulation in raised wood -frame floor orequivalent U- factor. §150.0 ft Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3 %; water vapor permeance rate is no greater than 2.0 permlinch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U- factor of 0.58. 2. The weighted average U- factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area,, whichever is greater, is exempt from the maximum U- factor requirement. §150.0(r) Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory-built fire laces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0- §110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §11 0.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu /hr are exempt), and pool and spa heaters. §150.0(h): Heating and /or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)lA: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R -12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water - heating system, or other indirect hot water tanks, have R -12 external insulation or R -16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoR User Number. 1919 ID: P14 -7280 Page 11 of 17 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 WAR Project Name Date SINGLE HOUSE 2ND UNIT 101812014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3 -A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3 -A. §150.0(1)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water - heating systems and /or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)l: All air - distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6 -5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R -6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct- closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross - sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)l: Systems using gas or propane water heaters, whether tank or on- demand, to serve individual dwelling units shall include all the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent.with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu /hr. §150.0(o): All dwelling units shall meet the requirements of ANSI /ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150.0(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)lA: Installed luminaires shall be classified as high - efficacy or low- efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0 -A or TABLE 150.0 -B, as applicable. §150.0(k)IC: The wattage of permanently installed luminaires shall be determined asspecified by 130.0 c . §150.0(k)ID: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)l E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number. 1919 ID: P14 -7260 Page 12 of 17 MANDATORY MEASURES SUMMARY: Residential (Page 3, of 3 WAR Project Name Date SINGLE HOUSE 2ND UNIT 1101812014 150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §1 50.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section' 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be hi 2h efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing /rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single - family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: L Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor; or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low -rise multi - family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low -rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable re uirements in Sections 110.9 130.0, 130.2 130.4 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §1 30.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low -rise multi - family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low -rise multi - family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of in ress and egress. EnergyPro 6.3 by EnergySoft User Number.- 1919 /D: P14 -7280 Page 13 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date SINGLE HOUSE 2ND UNIT 10/8/2014 System Name Floor Area WHOLE HOUSE 800 ENGINEERING CHECKS Number of Svstems Total C Output Cooling S' Output Total C Total C Total C Total 0 Air S stern CFM pc Airflow Outside Air (% Outside Air of Note: values above HEATING SYSTEI 28 OF 70 OF Outside Air 0 cfm 70 OF at ARI 800 HVAC EQUIPMENT SELECTION 800 CARRIER 24ABB324/58CVA- 070 -12 (2 TON)' 1.00 421.1 0.0% Total Adjusted System Output 0.00 (Adjusted for Peak Design conditions) :ions TIME OF SYSTEM PEAK 16,4061 5,1761 1 40,8001 16,4061 5,1761 1 40,800 Aug 3 PM Jan 1 AM 70 OF 105 OF Coo, � - � I __lCE1U- Supply Fan Heating Coil 105 OF 800 cfm ........... .. _ .........._..... , ,� ROOM 70 OF PSYCHROMETICS (Airstream Temperatures at Time of Coolina Peakl 88/68 °F 75/61 OF 75161 OF 55/54 °F r Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 800 cfm 46.0% ROOM ., 75 / 61 OF 75 / 61 OF EnergyPro 6.3 by EnergySoft User Number.- 1919 RunCode: 2014- 10 -08T15 :24:38 ID: P14 -7280 Page 14 of 17 SYSTEM LOAD 1 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 40,800 Total Room Loads 237 5,042 449 217 8,083 40,800 Return Vented Lighting 0 51.0 Return Air Ducts 197 383 Return Fan 0 0 22,800 Ventilation F 0 0 0 0 0 22,800 Supply Fan 0 0 1.9 Supply Air Ducts 197 383 28.5 421.1 TOTAL SYSTEM LOAD 1 5,4351 4491 8,849 800 HVAC EQUIPMENT SELECTION 800 CARRIER 24ABB324/58CVA- 070 -12 (2 TON)' 1.00 421.1 0.0% Total Adjusted System Output 0.00 (Adjusted for Peak Design conditions) :ions TIME OF SYSTEM PEAK 16,4061 5,1761 1 40,8001 16,4061 5,1761 1 40,800 Aug 3 PM Jan 1 AM 70 OF 105 OF Coo, � - � I __lCE1U- Supply Fan Heating Coil 105 OF 800 cfm ........... .. _ .........._..... , ,� ROOM 70 OF PSYCHROMETICS (Airstream Temperatures at Time of Coolina Peakl 88/68 °F 75/61 OF 75161 OF 55/54 °F r Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 800 cfm 46.0% ROOM ., 75 / 61 OF 75 / 61 OF EnergyPro 6.3 by EnergySoft User Number.- 1919 RunCode: 2014- 10 -08T15 :24:38 ID: P14 -7280 Page 14 of 17 ROOM LOAD SUMMARY Project Name Date SINGLE HOUSE 2ND UNIT 101812014 System Name Floor Area WHOLE HOUSE 800 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent CFM Sensible FLOOR PLAN IFLOORPLAN 1 1 2371 5,0421 449 2371 5,0421 4491 2171 8,083 Total includes ventilation load for zonal PAGE TOTAL TOTAL* 237 5,042 449 217 8,083 237 5,042 449 217 8,083 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE 2ND UNIT Date 101812014 ROOM INFORMATION DESIGN CONDITIONS Room Name FLOOR PLAN Floor Area 800.0 ftz Indoor Dry Bulb Temperature 70 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = 42 Btu /hr R -30 Roof Attic 800.0 0.0310 42 1,042 R -15 Wall 817.0 0.0950 42 3,260 Double Non Metal Clear (6) 103.0 0.3000 42 1,298 R -19 Floor Crawlspace 800.0 0.0370 42 1,243 Items shown with an asterisk ( *) denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 800 X Area another room 8.00 X 0.257 Height ACH Page Total /60] X AT 6,842 = 1,241 TOTAL HOURLY HEAT LOSS FOR ROOM 8,083 EnergyPro 6.3 by EnergySoR User Number.- 1919 RunCode: 2014- 10- 08T15:24 :38 ID: P14 -7280 Page 16 of 17 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE 2ND UNIT 1 101812014 ROOM INFORMATION DESIGN CONDITIONS Room Name FLOOR PLAN Outdoor Dry Bulb Temperature 88 OF Floor Area 800.0 ft2 Outdoor Wet Bulb Temperature 68 OF Indoor Dry Bulb Temperature 75 OF 1 Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area U- Factor CLTD' Btu /hr R -30 Roof Attic (N) 800.0 X 0.0310 X 37.0 = 918 R -15 Wall (Kq 188.0 X 0.0950 X 13.0 = 232 R -15 Wall (E) 180.0 X 0.0950 X 13.0 = 222 R -15 Wall (N) 236.0 X 0.0950 X 3.0 = 67 R -15 Wall (S) 213.0 X 0.0950 X 6.0 = 121 R -19 Floor Crawlspace 800.0 X 0.0370 X 4.0 = 118 X X = X X = X J X = Page Total 1,679 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr WINDOWS (K9 0.0 X 8.3 + 0.0 X 21.1 = 0 WINDOWS (E) 0.0 X 8.3 + 8.0 X 21.1 = 169 WINDOWS (N) 0.0 X 8.3 + 36.0 X 8.3 = 298 WINDOWS (S) 0.0 X 8.3 + 59.0 X 11.5 = 676 X + X = X + X = X + X = X + X = X + X = Page Total 1,143 Internal Gain Btu /hr Occupants 2.4 Occupants X 245 Btuh /occ. = 588 Equipment 800 Floor Area X 0.50 w/g Q ft = 1,365 Infiltration: 1.077 X 0.65 X 29.33 X 13 = 267 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM - 5,042 Latent Gain Btu /hr Occupants 2 4 Occupants X 155 Btuh /occ. = 372 Infiltration: 4,830 X 0.65 X 29.33 X 0.00084 = 77 Air Sensible CFM ELA Aye/ TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 538 EnerqvPro 6.3 by EnerqvSoff User Number., 1919 RunCode: 2014- 10- 08T15:24 :38 ID: P14 -7280 Pa a 17 of 17