Loading...
B-2016-3089CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7529 WATERFORD DR CUPERTINO, CA 95014-5233 17 022) CONTRACTOR: PERMIT NO: B-2016-3089 (366 COBALT POWER SYSTEMS INC MOUNTAIN VIEW, CA 94043 OWNER'S NAME: SUBRAMANIAM PARI AND PARI SUCHITRA DATE ISSUED: 11110/2016 OWNER'S PHONE: 408-623-1258 PHONE NO: (650) 938=9574 LICENSED CONTRA TOR'C D i ARATTON BUILDING PERNHT INFO: License Class C-1 Q Lie. #820697 Contractor COBALT POWER SYSTEMS INCDate 06/30/2017 X BLDG X ELECT —PLUMS I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing — MECH X RESIDENTIAL — ComAILRCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: I hereby affirm under penalty of perjury one of the following two declarations: (1) 14 -PANEL ROOF MOUNTED PV SYSTEM (4.5 KW); (N) m. I have and will maintain a certificate of consent to self -insure for Worker's SUBPANEL (125 AMP); OUTLET FOR EV CHARGING STATION Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. P have and will maintain Worker's Compensation Insurance, as provided for by /Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT Sq. Ft Floor Area: Valuation: $13219.00 CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type:. information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize 36617 022 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence the granting of this permit. .Additionally, the applicant understands and will comply with all non -point l WITHIN 180 DAYS OF PERMIT ISSUANCE OR source regulations per a Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. _ naturS �� e U 9 Date 1� Issued by Abby && de (� OWNEWBUI DERDECTARATION Date: 11/10/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOF following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is m. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: I hereby affirm under penalty of perjury one of the following three declarations; m. I have and will maintain a Certificate of Consent to self -insure for Worker's ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. 1 have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the s. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous Worker's Compensation laws of California. If, after making this certificate of air contaminants as defined by the Bay Area Air Quality Management District I - exemption, I become subject to the Worker's Compensation provisions of the will maintain compliance with, the Cupertino Municipal Code, Chapter 9.12 and the Health &Safety Code, Secti s 5 O5, 25533, and 25534. Labor Code, I must forthwith comply=with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION Owner or auth rig ed agent: Date: (1 lb �j I certify that I have read this application and state that the above information is l t CONSTRUCTION LENDING A ENC Y correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Signature Date Licensed Professional ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 CUPERTINO (.408) 777-3228 o FAX (408)" 777-3333 - building a.cupertino,orc B-zol(0- 3w AE PROJECT ADDRESS •� 9 � � j i Ia n Y � �q Y� Dr 1 �V C \/ I VV- APN 11 OWNER NAME PHONE III� - EMAII 1'icA" aYilr�n "(,� '1 1-i e S(�t7YamaYliarn �� STREET ADDRESS CITY, STATE, ZIP " I FAX i 1 " CONTACT NAME �y E ±PHONF6y FAX 1 /� jOMSTREET ADDRESS .155 / i , &y)dd-f f ST l VV 1 Y� c� ❑ OWNER. ❑ OWNER -BUILDER ❑ OWNERAGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ,❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTORN _ ` �m oba It �u r 5 si LICENSE NUMBER �n � 61 -1 LICENSETYPE G- (0 BUS: LIC#`� d LIQ � I i COMPANY NAME ` �% - Cobalt 1 01!10 yi E-MAIL FAX STREET ADDRESS �5 C STATE, ZIP t7� -fia ► viPu�, C,/4 gL10L(S ,-12, ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANYNAME - EMAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF X SFD Or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO /EksOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY):TOTAL VALUATION.,513, 3/ l:lJ DESCRIPTION OF WORK I j e kW p\) C O) ®n 9 �/V V J roo-T Q4 S1nCje -4aM' j'4 tAkVJ I-' s>&b p&nP L Lk vd NLMA P-50 OvMp# CEIVED BY. F By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behAlf. I ha e read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building o struction. I authorize representatives of Cupertino to enter the abov identified property for inspection purposes. Signature of Applicant/Agent: = y (i/I/Vi�J Date: 1 �a 14 SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY � (i/�l �L� 3^ +� ❑ OVER -TIM -COUNTER ❑ EXPRESS WV 'p7 °U ❑' STANDARD El LARGE, a ❑ MAJOR PVApp 2011.doc revised 03116/11 oco+m SMOKE/ CARBON MONOXIDE ALARMS OWNER CERTIFICATE -OF -COMPLIANCE; COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION . ` I In. -inn TnRRF AVFNI !F . ('1IPr:17T Inln r -n ncn-i n o�cc 1 Ultl"VDL" i I This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA I SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) { X X On every level of a dwelling unit including basements X X A Within each sleeping room X i Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. I Power Supply: In dwelling units with no commercial power supply, ala,,rm(s) may be solely battery operated. hi existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.62. An electrical permit is required for alarms which must be connected to the building wiring. i As owner of the above -referenced property, I hereby certify that the alam(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the I date signed below. of k -,D 9 LV Address: 15 2,9 ry 1 ,V( �`) Permit No. Specify Number of Alarms: # Smoke Alarms: # Carbon M"onoxide Detectors: I have read and agree to comply with the terms and conditions of this statement Owner (or Owner Agent's) Name: Signature .... .................. ... ........i............. ..��..............................I...........................�� ............. ................ Date: ............................ Contractor Name: Signature...........................................................1...... Lic.# ......................................Date: Smoke Mid CO}67-m.doc revised 09/27116 0 CUPERTINO Owner Name 9 I WATER -CONSERVING PLUMBING FIXTURES: -c/7 rX OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 Ca Address p > 4 i up &0-f D rfbfL� 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 110 1. 1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. U/Ko Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically fealible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. INO Go to Question 3. 3. Is water service permanently disconnected for your building? i ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest If the form and sign bottom of form. o Go to Question 4. 4., Is your real property built and available for use or occupancy on or before January, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the restoif the form and sign bottom of form. L�✓Yes My real property is built and. available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the thrIIee following statements and sign bottom of form.. Plea check ONE of the following: My property is a single-family residential real property. See Civil Code Section On and after January 1, 2014, building alterations or improvements shall requi to be replaced with water -conserving plumbing fixtures throughout the building. compliant plumbing fixtures shall be replaced with water -conserving plun property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1 On and after January 1, 2014, specified building alterations or improvements shy plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be repla conserving plumbing fixtures throughout the building (regardless of whether pro improvements). ❑ . My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements sha plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall b, plumbing fixtures throughout the building (regardless of whether property under 101.4. all non-compliant plumbing futures )n or before January 1; 2017, all hon- ing fixtures (regardless of whether 01.5. 1 require non- compliant with water- y undergoes alterations or require non- compliant replaced with water- conserving )es alterations;or irnprovements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply vith the requirements as indicated in the table on the followina Daae. � r% Owner or Owner Agent's Signature: ( JA it .IA, C, 1XrU,,Date: 12-1 t-1 d-6 Upon completing and signing this Certificate, please return it to the Building Division in order to final your building permit. SB40 7 2015.doe revised 08126115 1. If the existing plumbing lixture water usage/now raLu is vqu a, Lu u, -1 SB407 2015.doc revised 08126115 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixture I (Fixture Complying with Current Cdde Applicableto New Construction) Maximum WateilUsage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 C . rQ Ch. 4 2013 CPC Ch. 4 2013 CALGreen Div. 4.3 2013-CALQreenDiv. 4.3 2013 CALGreen Div. 5.3 /Flow Rate Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush jeffective flush volume (the composite, average flush volume of two reduced flushes and one full flush) Urinals Exceed 1.0 0.5 gall'p'ns/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also ceHfied to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower Outlets controlled by:a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: Maximum 11.5 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum 0.8 minute @ gallons per minute I 60 psi; psi Faucets gallons per 20 psi minimum 03 gallons I per minute @ 20 psi In commonjand public use areas: 1 0.5 gallons per minute @, 60 psi 1.8 gallons per minute 60 psi Faucets Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up, to 2.2 minute @ 60 psi, and must gallons perlminute @ default to maximum 60 psi, and Imust 1.8 gallons per minute @ 60 default to maximum 1.8 gallons �er minute psi Where faucets meeting @ 60 psi I the above are unavailable, Where fauc6ts meeting aerators or other means the above r may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. I---- .1__ c. J_,, _L-- '+;V "- — ...1a1 to haimararlrri 1. If the existing plumbing lixture water usage/now raLu is vqu a, Lu u, -1 SB407 2015.doc revised 08126115 Existing Service Panel, and PG&E Meter Mount New Subpanel on Exterior Wall AC Lines to New NEMA 14-50 Outlet to be THWN-2 in EMT and Romex Through Structure Mount New NEMA 14-50 Outlet On Interior Garage Wall Legend OL -New NEMA14-50 Outlet SP Subpanel SE - Service Entrance Panel - Roof Mounted PV Array (14) LG Neon2 LG320N1 C -G4 (14) Enphase S280 -60 -LL -2 -US Total Area 250 sq ft, Total Weight 705 lbs 2.8 lbs/sq ft, See Sheets 2 and 3 Property Line Run AC Lines in Watertight. Metallic Conduit on Roof and Along Wall, and Romex Through Structure Paint to Match Existing (Where Visible) AC Wires to be Type THWN-2 Or Romex Through Structure w � 11 0- F-1 F-1 � 1 o 'I See Sheet 2 of 7 For PV Array Layout Driveway.. ' I Property Line Waterford Drive — ``S�ite�yPlaaniy�gy SCVPI�y1IIYV Bu Ing epa mE JJJ__ Existing Residence ra�OOMMUNITY DEVELOPMENT DEPARTM NT BUILDING DIVISION -CUPERTINO APPROVED This set of plans and specifications MUST be kept at the job site during construction. It s unlawful to make any chang s o alterations on same, or to deviate therefrom, without app va from the Building Official. The stamping of this plan and spec f catmns SHALL NO be held to permit or to be an approval of the violation of a y provision of any City Ordinance or State Law. DATE 11/15/16 PERMIT NO B-2016 Tff 11 111 111 IIIIJULILI ILI Ifir HIM v v v v i"' N 111 11 1 v v JJ11111J111 1-14 1-13 1-12 1-11 1-10 1-9 1-8 1-1 1-2 1-3 1-4 1-5 1-6 1-7 / Space Between PV Modules / / AA Existing Roof Pitch 22° or 3 of 7 4:12 From Horizon Mat'l: Comp Shingle Legend V Vent Roof Mounted gray, 1 String(s) Total Project Subramaniam Residence Photovoltaic System X (14) LG Neon2 LG320N1 C -G4 rra La out Address Individual Module Dimensions are 64.6" X 39.4" 3/16PERTINQ 7529 Waterford Drive, Cupertino CA 95014 BU mQ epa meal 2557 wy-dofte St Mt View, CA 94043 Date Drawing Title Rev 36" Cal. Fire Clearance, Typ. � � REVIEWED FOR- 0_ QJLDNtl'6BLT Tei 6s0-9389574 Nov 7, 2016 PV Array Layout 2 r ILL/�J P WER SYSTEMS INC. w- bdtp-3 Reviewed By: bW R en�e P"wer_�m y y Cobalt Power Sy --,Inc. Sheet Signed 2 of 7,l 6991#0.of-ZP10J-1eM6Z SL N CIO a, 0 o � o a � a � � U U 5 'd eo Q � � O N � h ' O 3 N�Hwao z z wb LL r� N C � � 7 13 Lu U � � o m m o v _ u, v z z •— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — i 'IO �r000 ��wCa o o zw � W o 0 a M N ti O N N N a. v C4 0 ro z � o 6991#0.ot-Zpz J-1; Ak6ZSL w e b'yvoe<v�aav�'�b-va<evaBe�"�a��ra as ro `�°Ca `v°v V V w 4`� a 4`%`� a v a O c � ��"vvv°'v uveavvvv°'v vaevavvvvw°'v 4 r� F4 CIO a,W p�� mMm ro Q N N F a s � �u mmmNp ccs m ao a'�mmmm Mma�mm m rn oa Nom aW mmm�rnm �i'naw a��m N f O d IK J a yy a p r r 0 5 4 r 117 V V G �Uw _ 3 N�Hwao z z L r � N C � O E� ro Z 6D aC p ~ N 13_T LWLj � o s z N >� p O �a b a� N� a a w � p � � P, nn w N N F Z a ��m mammm`Sirnmm mmm�rnm �i'naw a��m �mn�e f J a p r r r 117 V V G 6991 #0.of-Z P10J-1eM6Z SL 0 •U �� �qq �a maw Awa CIO 4n G tfa, is Pi Py Py 0.i �j O O .7 .7 .7 .7 E E ro ro ro O t. to O t CIO Cd W W W W Qi A bA �' ab ab ab ab a,d � Ca w w w w w p p., Qi O o v�Ua aO aO fib; ,� N H w a o o z o z o �Ca aa6' aa6'��'z ova z 000000 � °' p W d iL U � o 0 m o m w v z z G 0 D d N � 0 i o i i _ ------— — — — — — — E7 o a, is-- r; w U w 7-S U N Py w M p N a U a 0 > o 6991 #0.of-Zpzo3za;eM6ZSL N CIO a, � U O p O V x � 60 ¢ o �, p o q a w o °6 0 6 0 "ate 2 o d Uo _ C ou >p o x o o U H yu x x u>�9a� Ip o y 6 o p 6 H r o w vo r-- 0 ya _ �-k5 > K o . R > q q U att g U m> U 6 io Q 9 o u a a a o p .a '"'SSSS. 6 ; ,9 s,. m .c •^• o ,d E; ,'� ,�' �oFj �Uw _ — > ° 3 3 N�Hwao z L z r W "N c No 9 0 d w Z OO a� za W Q a m Q m rj /T/ ❑ w v L^J S a H afar a L^J > a a ar rTa o rte, r� m asoma r�� I Hw�"ao a V v I I U \\\1` lit I I II II W .a � I U V L ---J 3 ] 2 \ \ ( ƒ \ \ \ # = g ) Q � , \ ) ) ® J § \)y) } j\}) / / ® \\\)� rTzz� Li �( \\ (� 2 k cc CL Lu -A ))\ J 2 �\ \F))// < - i� { � /° \\ )�y /} 2 (\ \ r : /lam IRONRIDGE Flush Mount System R! flit fnr RoInr'_c tni.jrihpct rnnfc IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20 -year warranty. Strength Tested PE Certified All components evaluated for superior® Pre -stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance® Online software makes it simple to rating of the existing roof. create, share, and price projects. Integrated GroundingCUPERTINO UL 2703 system eliminate td3uilding Department module grounding compo REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende Date: 11/15/16 20 Year Warranty Twice the protection offered by competitors. XR Rails XR10 Rail A low -profile mounting rail for regions with light snow. • 6'spanning capability • Moderate load capability • Clear & black anod. finish Attachment; FlashFoot XR100 Rail XR1000 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Slotted L -Feet A heavyweight mounting rail for commercial projects. • 12'spanning capability • Extreme load capability • Clear anodized finish Standoffs Internal Splices All rails use internal splices for seamless connections. • Self -tapping screws • Varying versions for rails • Grounding Straps offered r d Anchor, flash, and mount with Drop-in design for rapid rail Raise flush mount system to various all -in -one attachments. attachment. heights. • Ships with all hardware High -friction serrated face Works with vent flashing • IBC & IRC compliant Heavy-duty profile shape Ships assembled • Certified with XR Rails Clear & black anod. finish 4" and 7" Lengths viuiilt.D9 bL %AlUU1lull End Clamps Grounding Mid Clamps T Bolt Grounding Lugs Accessories Aft -Vogu-— �.�- Slide in clamps and secure Attach and ground modules modules at ends of rails. in the middle of the rail. • Mill finish & black anod. • Sizes from 1.22" to 2.3" • Optional Under Clamps Free Resources • Bonding T -bolt • Reusable up to 10 times • Mill & black stainless Ground system using the rail's top slot. • Easy top -slot mounting • Eliminates drilling • Swivels in any direction Provide a finished and organized look for rails. • Snap -in Wire Clips • Snap -in End Caps • UV-stabalized polymer y_ - _ Design Assistant NABCEP Certified Training - Go from rough layd CUPE Earn free continuing education credits, engineered syste o L A6, while learning more about our systems. �u iv I�uii1iiCigeX 'Building Dep, int iaV gay ii vi REVIEWED FOR CODE COMPLIANCE Reviewed bb Ayende 0 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 LC Life's Gc LG NeON"2 LG's new module, LG NeONT" 2, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires ETAnPPRoveD PRODUCT 60 cell to enhance power output and reliability. LG NeONT"' 2 p�/E I DS demonstrates LG's efforts to increase customer's values MCS, beyond efficiency. It features enhanced warranty, durability, Intertek IMI 564573 BS EN 61215 performance under real environment, and aesthetic Ph.—It— design suitable for roofs. Enhanced Performance Warranty d"""•• High Power Output LG NeONT"" 2 has an enhanced performance warranty. _______ Compared with previous models, the LG NeONT" 2 The annual degradation has fallen from-0.7%/yr to =_______________ has been designed to significantly enhance its output ---0.6%/yr. Even after 25 years, the cell guarantees 2.4%p ------ efficiency, thereby making it efficient even in limited space. more output than the previous LG NeONT" modules. Aesthetic Roofelk Outstanding Durability :: -__ LG NeON " 2 has been designed with aesthetics in mind; With its newly reinforced frame design, LG has extended ___________ thinner wires that appear all black at a distance. the warranty of the LG NeON " 2 for an additional The product may help increase the value of 2 years. Additionally, LG NeONT" 2 can endure a front a property with its modern design. load up to 6000 Pa, and a rear load up to 5400 Pa. Better Performance on a Sunny Day Double -Sided Cell Structure _____!_ LG NeONT" 2 now performs better on sunny days thanksThe rear of the cell used in LG NeON " 2 will contribute to to its improved temperature coefficiency=___________ generation, just like the front; the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. CUPERTINO About LG Electronics iml Lt LG Electronics is a global player who has been committed to expanding its c n solar energy h mess a its future growth engine. We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi -conductor, LCD, chemistry, q�� dustry. We successfully released first Mono Xo series to the market in 2010, which were exported to 32 countries in the following 2 years, thereafter. In 2013, NeON- (previously known as Mono Xx REVIEWED 2 Fde e( SDE E66technnul gy�yo� Inter solar Award", which proved LG is the leader of innovation in the industry. U HIV Reviewed By:Abby Ayende Date: 11/15/16 LG■ LG320N1C-G4 Mechanical Properties Electrical Properties (STC * Cells 6 x 10 Module Type 320 W Cell Vendor LG MPP Voltage (Vmpp) 33.6 Cell Type Monocrystalline / N -type MPP Current (Impp) 9.53 Cell Dimensions 156.75 x 156.75 mm / 6 inches Open Circuit Voltage (Voc) 40.9 e of Bus bar 12 (Multi Wire Busbar) ' Short Circuit Current (Isc) 10.05 Dimensions (L x W x H) 1640 x 1000 x 40 mm Module Efficiency (%) 19.5 64.57 x 39.37 x 1.57 inch Operating Temperature (°C) -40-+90 Front Load 6000 Pa / 125 psf 0 Maximum System Voltage (V) 1000 Rear Load 5400 Pa /113 psf io Maximum Series Fuse Rating (A) 20 Weight 17.0 ± 0.5 kg / 37.48 ± 1.1 lbs Power Tolerance (%) 0-+3 Connector Type MC4, MC4 Compatible, IP67 STC (Standard rest condition): irradiance 1000 W/m, Module Temperature 25 °C, AM 1.5 Junction Box P67 with 3 Bypass Diodes The nameplate power output is measured and determined by LG Electronics at its sale and absolute discretion. * The typical change in module efficiency at 200 VV/m2 in relation to 1000 W/102 is -2.0%. Length of Cables 2 x 1000 mm / 2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Electrical Properties (NOCT*) Certifications and Warranty Module Type 320 W Maximum Power (Pmax) 234 Certifications IEC 61215, IEC 61730-1/-2 MPP Voltage (Vmpp) 30.7 IEC 62716 (Ammonia Test) MPP Current (Impp) 7.60 IEC 61701 (Salt Mist Corrosion Test) Open Circuit Voltage (Voc) 37.9 ISO 9001 Short Circuit Current (Isc) 8.10 UL 1703 NOCT (Nominal Operating Cell Temperature): Irradiance 800 W/m', ambient temperature 20 °C, wind speed 1 m/s Module Fire Performance (USA) Type 2 (UL 1703) Fire Rating (for CANADA) Class C (ULC/ORD C1703) Dimensions (mm/in) Product Warranty 12 years Output Warranty of Pmax Linear warranty* * 1) 1 st year 98%, 2) After 2nd year 0.6%p annual degradation, 3) 83.6% for 25 years Temperature Characteristics s s NOCT 46 ± 3'C Pmpp -0.38 %/oC D -1X �« pl-1Ylll D -1Z 9 ef... sh- Ad. f.me Voc -0.28 %/°C Isc 0.03 %/°C �x g2Q22x016 ,�.a� Characteristic Curves 1 1000W 0.00 ..an 800W 600W 6.00 4 40OW .00 ,.an 200W votrage N) 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 a 120 100 ao 60 40 20 0 * The distance between the center of the mounting/grounding hales. (8 LG North America Solar Business Team ct sPec ificat� t o; ss a s bjecl I IY 6 without notice. LG Electronics U.S.A. Inc 2-60-C 2R Life's Good 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact: lg.solar@lge.com igzO www.lgsolarusa.com `J' YBCu�i(ldf Fje jYep&�ived. REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende Date: 11/15/16 I 00 Innovation for a Better Life : �J J� - r ■ r Enphase Microinverters EnphaseS280 Designed for high-powered, 60 -cell modules, the advanced grid -ready Enphase S280 Microinverter'" is built on the fifth -generation platform and achieves the highest efficiency for module -level power electronics along with cost per watt reduction. With its all -AC approach, the S280 simplifies design and installation for 280 VA installations, and delivers optimal energy harvest. The S280 is compatible with storage systems, including battery management systems. The Enphase S280 integrates seamlessly with the Enphase Envoy -S'" communications gateway, and Enphase Enlighten'" monitoring and analysis software. PRODUCTIVE - Optimized for higher -power, 60 -cell modules - Maximizes energy production - Minimizes impact of shading, dust, and debris SIMPLE AND RELIABLE - No GEC needed for microinverter - No DC design or string calculation required - More than 1 million hours of testing - Industry-leading warranty, up to 25 years CUPERTINO Building Department EN PHAS E. REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende Date: 11/15/16 ADVANCED GRID READY - Complies with fixed power factor, voltage and frequency ride -through requirements - Remote updating to respond to changing grid requirements - Configurable for variable grid profiles like Hawaiian Electric Company (HECO) Rule 14H, California Rule 21 Enphase S280 Microinverter // DATA INPUT DATA (DC) S280 -60 -LL -2 -US, S280 -60 -LL -5 -US Commonly used module pairings' 235W -365W Maximum input DC voltage 48V Peak power tracking voltage 27V - 37V Operating range 16V -48V Min/Max start voltage 22V/48V Max DC short circuit current 15A OUTPUT DATA (AC) 208 VAC 240 VAC Peak output power 280 VA 280 VA Maximum continuous power 270 VA 270 VA Nominal voltage/range2 208 V / 183-229 V 240 V / 211-264 V Nominal output current 1.30 A 1.13 A Nominal frequency/range 60 / 57 - 61 Hz 60 / 57 - 61 Hz Extended frequency range 57 - 63 Hz 57 - 63 Hz Power factor at rated power 1.0 1.0 Maximum units per 20 A branch circuit 21 (three phase, balanced) 14 (single phase) Maximum output fault current 663 mA rms,100 ms 663 mA,100 ms Power factor (adjustable) 1 / 0.7 leading ... 0.7 lagging 1 / 0.7 leading ... 0.7 lagging EFFICIENCY 208 VAC 240 VAC CEC weighted efficiency 96.5% 97.0% Peak inverter efficiency 96.8% 97.3% MECHANICAL DATA Ambient temperature range Connector type Dimensions (WxHxD) Weight Cooling Enclosure environmental rating -40°C to +65°C S280 -60 -LL -2 -US: MC4 S280 -60 -LL -5 -US: Amphenol H4 172 mm x 175 mm x 35 mm (without bracket) 1.8 kg (4 lbs) Natural convection - No fans Outdoor - NEMA 6 FEATURES Compatibility 60 -cell PV modules Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Ground fault protection (GFP) is integrated into the microinverter. Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 1. Suggestion only, inverter self limits DC inputs. 2. Nominal voltage range can be extended beyond nominal if required by the utility. CUPERTINO Building Department To learn more about Enphase Microinv --- nology, visit enphase.com REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende © 2016 Enphase Energy. All rights reserved. All trademarks orands in t 1� 1(6[ifSt are registered by their respective owner. Date: ENPHASE. January 2016