Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14020167
1479 POPPY WAY 14020167 F MANISHA VADHIA SCANNED BOX #656 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1479 POPPY WAY CONTRACTOR: MANISHA VADHIA PERMIT NO: 14020167 OWNER'S NAME: MANISHA VADHIA 1479 POPPY WAY DATE ISSUED: 12/10/2014 OWNER'S PHONE: 4082423639 CUPERTINO, CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ CONSTRUCT ONE STORY ADDITIONS (521 SQ FT); License Class_ Lic. /1 REMODEL FIRST FLOOR (928 SQ FT); REMODEL SECOND FLOOR Contractor Date (128 I hereby affirm that I am licensed tinder the provisions of Chapter 9 SQ FT); RELOCATE AND UPGRADE ELECTRICAL PANEL (commencing with Section 7000) of Division 3 of the Business & Professions (200 Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $100000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 36615025.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 D ALLED INSPECTI N) indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply a e: / Il with all non -point source regulations per the Cupertino Municipal Code, Section / -� 9.18. RE -ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Section 2 25 and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner Date: permit is issued. or authorized agent: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulatip4pef the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date ( v I CITY OF CUPERTINO BUILDING PERMIT 1 BUILDING ADDRESS: 1479 POPPY WA OWNER'S NAME: MANISHA Vgb iIA CONTRACTOR: JON ANDERSON BUILDS PERMIT NO: 14020167 PO BOX 320094 DATE ISSUED: 12/10/2014 OWNER'S PHONE: 4082423639 1 LOS GATOS, CA 95032 ' PHONE NO: (408) 761-2098 1 ❑ LICENSED CONTRACTOR'S DECLARATION License Class___ Lie. #L- ContractoN-)blU Y'Vlrt JAg)1 1�; [UW Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1 have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain Worker's Compensation Insurance, as provided for by ection 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION l certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments. costs, and expens which may ccrue against said City in consequence of the granting of this Orin, Additi ally, the applicant understands and will comply with all non- u ource egt tions per the Cupertino Municipal Code, Section 9.18. Lis Signatur Date '1 15 ❑ OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and die structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. JOB DESCRIPTION: RESIDENTIAL COMMERCIAL ❑ CONSTRUCT ONE STORY ADDITIONS (507 SQ FT); REMODEL FIRST FLOOR (928 SQ FT); RELOCATE AND UPGRADE ELECTRICAL PANEL (200 AMP). Sq. Ft Floor Area: I Valuation: $100000 APN Number: 36615025.00 1 Occupancy Type: PERMIT EXPMES IFW-ORK IS NOT STARTED WITHIN 180 YS PRMIT ISSUANCE OR 180 DAYS FRO LACALLED INSPECTION. Issued by: Date: RE -ROOFS - All roof's shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use a ipment or devices which emit hazardous air contaminants as defined by the B Area A' Quality Management District I will maintaiu compliance with the pertien u i1ipnl Code, Chapter 9.12 and the Health & Safety Code, Section 25505 2 33, and 25534. Owner or authorized agent: Date: fsf fXn 1 hereby affirm that there il'a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Add ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Profess Signature_ Date CUPERTINO t ^� CONSTRUCTION PERMIT APPLICATION O� COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildinq(@cupertino.org ❑ NEW CONSTRUCTION Z ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT It PRO.iBCT ADDRESS Dfei / O7PN # rf / / Y /t Z G- OWNER NAME MAN f � ({ A,. V /� D A 1�1f1 /�fH PHONE � !1 _ �/_ E-MAIL _ 1 /J l� • STREET ADDRESS CITY, STATE, ZIP !`� /I�O V FAXG(f CONTACT NAME MA}2K �t �RAY0 PHONE (1(1 j1Q( -70E l 32,Z E-MAIL STREET ADDRESS 2� 's �r n ``� vJ CITY, STAT ' r �C } � V mil/ �� FAX VAREHrrEe-t ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME EMAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NvTUMBER BUS. LIC # COMPANY NAME tom! N ^ T. E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK �2C9�b►11Oc'V 71r�-off AT/� r3 1<rrcrt`�-ill t4. ar� EXISTING USE cliA1��IL / V !' PROPOSED USE CONSTR Vv te fil"� e , °U"DP TYPE v� # STORIES 2 USE TYPE OCC, SQ.FT. VALUATIONS) EXI`-ST`-G-' AREA / r 3 6 NEW FLOOR�O AREA �!Z O � � AREA TOTAL NET AREA BATHROOM REMODEL AREA 60 KITCHEN REMODEL AREA OTHER REMODEL AREA PORCH AREA DECK AREA TOTAL DECKIPORCH AREA GARAGE AREA: DETACH h / ATTACH # DWELLING UNITS: IS A SECOND UNIT ❑ YES SECO STO Y YES BEING ADDED?'O ADDrF10N? NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES D B - a ''—''� TOTAL VALUATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LFITER EICHLER HOME? ❑ N 00 ©06 By my signature below, I certify to each of the following: I am the property owner or authorized agen t on the property owner's behalf. I have read this application and the information I have provided is correct I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to build' truction. I author' representatives of Cupertino to enter the above-iden 'fied pr petty for inspection purposes. Signature of Applicant/Agent: Date: 02 02 SUPPLEMENTAL TION UIRED PLAN CHECK TYPE ROUTING SLIP ❑ OVLR-TH-E-COUNTER ❑ BUILDING PLAN REVIEW New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. - ❑ EXPRESS ❑ PLANNFNG PLAN REVIEW Commercial Bidgs: Provide a completed Hazardous Materials Disclosure ❑ srA DARD ❑ PUBLICwORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with.Planning prior to ❑ MAJOR Q SANITARY SEWER DISTRICT submittal of Building Permit application. -❑ ENVIRONMENTAL HEALTH 1-M BldgApp_2011.doc revised 06121/11 CITY OF CUPERTINO I FEE ESTIMATOR - BUILDING DIVISION y F ' �4 ADDRESS: 1479 POPPY WAY DATE: 02/28/2014 REVIEWED BY: MELISSA APN: 366 15 025 BP#: O20 `VALUATION: j$100,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: 2nd Unit? Yes No OTC? ® Yes �No PENTAMATION PERMIT TYPE: 1 R3SFDADD WORK ADD 526 S.F. RELOCATE KITCHEN ADD 2 N BEDROOMS & 1 N BATHROOM. REMODEL 750 SCOPE S.F. OF 1ST FLOOR TO RECONFIGURE SPACE & REMODEL 2 FLR BATHRM (60 S.F.) o OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE 1D BP FEES BP FEE ID R-3 (Custom) II-B,III-B,IV,V-B 526 $2,577.00 I.R3PLNCK $1,617,00 IR31NSP TOTALS: 526 $2,577.00 $1,617.00 MECH, HOURLY O Yes 0 No PLUMB, HOURLY © Yes Q No ELEC, HOURLY Q Yes Q No Elec. Plan Check 0.0 hrs $0.00 Elec. Permit Fee: IEPERMIT Other Elea Insp. 0.0 hrs $47.00 NOTE. This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc.). These fees are based on the oreliminary information available and are only an estimate Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1%131 FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,577.00 750 s.f. $558.00 Remodel, Other IREMRESOTH Suppl. PC Fee: Q Reg. C) OT 0.0 hrs $0.00 PME Plan Check: $0.00 =s.f. $626.00 Remodel, Bath (<=300 sf) IREMRESBAT Permit Fee: $1,617.00 Suppl. Insp. Fee:(D Reg. Q OT 1 0.0 hrs $0.00 200 amps Electrical $47.00 IBELEC200 Services PME Unit Fee: $0.00 PME Permit Fee: $47.00 0 G) Work Without Permit? 0 Yes ( No $0.00 Advanced Planning Fee: IPLLONGR $73.64 Select a Non -Residential Building or Structure E) 0 A Travel Documentation Fee: ITRAVDOC $47.00 Strong Motion Fee: IBSEISMICR $10.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $4.00 SUBTOTALS: $4,375.64 $1,231.00 TOTAL FEE: $5,606.64 Revised: 01 /15/2014 Building Department 'I " l(el CUPERTINO CONTRACTOR / SUB'CONTRACTOR LIST City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 JOB ADDRESS: PERMIT # 1 02 OWNER'S NAME: PHONE # —2. 2 — 3 GENERAL CONTRACT a2 BUSINESS LICENSE # ADDRESS: {`�.0 ci CITY/ZIPCODE: 4l 37- *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing v'THeating p p Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering t-' Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile 1-7 / Contractor Signature / A� Date Cut ah" i 4 Tq po.pp � w &- v Cu Pc--2-r I N o, CA qsv i q (&)t)cdj 4-f-b 6k (n LA-) Aef / C'o C,o A--4,c, ch r , Co vvf-,- a-ci f 'b�e--f o- d s , Pe,4- OA-4 jD55�� JpN �at�i�t�SOI� BUIL-DS �a. (pax 3zm2� Zvi Sl CUPERTINO OWNER -BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 • building a4cupertino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS I �(� Po (�(� + Vw P rf v APN _' �- O � BP# OWNER NAME 1"I`C n Y�y t R OWNER ADDRESS t 4—+cl POPPY LA)A(tU P67e7((}bd DESCRIPTION OF WORK: V_MS1 GI, We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) 1vv"1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner - Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. V-0) 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. IVw 3. 1 understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her ",n�a1me instead of my own. �`�" 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. /W 5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. A16. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 0 7. 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. woj 8. 1 understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForin 2010.doe revised 04114110 9. 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. �10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. t8b1. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by Iall applicable laws and requirements that govern Owner -Builders as well as employers. 12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS: Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's drivers license, form notarization, or other verification acce to e to the ity may be required to be presented when the permit is issued to verify the property owners signature. Property Owner's Signature: - Date: 10 ILf --------------------------------------------------------------------------------------------------- —---------------- — ---------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the property owners drivers license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owners signature. Property Owner's Signature: Date: OwnerBuilderForm 2010.doc revised 04114110 (47� .| / | "Ch*-, e87spmnFnxCT. SRN Juss,cn yswo Pxowc: (q08)70s'7322 maxdcs/nnomun,m@nmaxzo 147UPOPPY WAY CUPERT|NDCA PERMIT NUMBER 14020167 Towhom itmay concern, � /� /This letter is to request an extension of permit # 14020167 for a single period of 1 �0 days We are currently applying for a minor residential permit for a non -conforming set back The tentative deadline for public comment will bennSeptember ll'2Ol4 Hoping for your kind consideration. Sincerely, Mark Neil 8ayo8 Mak Design g/oup.||c Designer CUPERTINO WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (4II08II) 777-`32/28 •FAX (4p8) 777-3333 • building(a cugertino.org j Owner Name � � 1,514 ' V -RDH if) Permit No. 1 `l A�w� 1� . Address J o t I �O p/ vqiovl- PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNE AND RETURNED TO THE BUILDING DIVISION Please refer to the attached California Civil Code Sections 1101.1 — 1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: ,/No Go to Question 2. Date: 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. Owner' Signature: /No Go to Question 3. Date: 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. J Owner' Signature: No Go to Question 4. Date: 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form Owner' Signature: Date: Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. .,.!'' My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non -compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB407 2014.doc revised 03118114 On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 1/We, the owner(s) of this property, certify under penalty of perjury that non -compliant plumbing fixtures have been replaced with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Buildin tan*rds Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply Ait 4a4�meAs as indicated in the table below. — , J ) Owner's (or Owner Agent's) Signature: 1.Wkill V-V',,V- = Date: ?5 / 41L Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit. Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. /5— SB407 2014.doe revised 03118114 r CALGREEN RESIDENTIAL CHECKLIST — MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT • BUILDIN DI AL BERT SALVADOR. P.E.; C.B.C., BUILDING OFFICIAL ir CUPERTINO fltC 10300 TORP.E AVENUE - CUPERTINO, CA95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildin cu ertino.orq copy PURPOSE: The 2013 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings, dormitories, condominiums, shelters, congregate residences, employee housing. faciory-built housing and other types of swellings with sleeping accommodaii;,ns acid iiew dccessory buildings associated with such uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name:Vadhia addition CUPERTINO ui rg e_ Project Address. 1479 Poppy Way Cupertino, C 114 Project Description: Addition and remodel NOV ,11 REVIEVVEU FOR C OO7 - COVIPLIANC-�- InstructoFs: l<eviewed By: �^� The Owner or the Owner's agent shall em ploy a licensed professional experienced with the Caiitornia Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans f or the project. Prior to final inspection by the Building Department, the licensed professional I c t and sign and date Section 2 - Implementation Verification at the end of this �L completed form to the Building Inspector. 3 Column 2 Column 3 MANDATORY FEATURE OR MEASURE Project Verification Reouirernents Planning and Design - Site Development 4.106.2 Storm water drainage and retention during construction. A plan is developed and implemented to manage storm water drainage during Q construction. 4.106.3 Grading and paving. The site shall be planned and developed to I keep surface water away from buildings. Construction plans shall indicate how j site grading or a drainage system will manage all surface water flows. j Page I of i e014 CalGreen_?014.doc revised 01115,14 i 3' t General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum M ❑ standard design required by the California Energy Standards. 1 Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: El 4.303.1.3.2 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank -type water closets shall be certified to the performance criteria of the U.S. EPA WaierSense Specifications for Tank -type Toilets. 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum flow rate of not more than 2.0 gallons per minute at 80 psi Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ❑ 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per rrunute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. ❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 ps: The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public, use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. ❑Q 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets . shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily Increase the flow aoove the maximum rate, but not to exceed 2.2 gallons Der minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fitirngs shall .ne installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1401.1 of the I California Plumbing Code. J ��NNENI Pa2c2of 5 CalGreen 2014. doe revised 01,115114 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the time of final inspection shall be weather -based. ❑ 4.304.1.1 Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. ❑ 4.304.1.2 Weather -based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controlier(s). Soil moisture -based controllers are not required to have rain sensor input. A4A MATERIAL CONSERVATION AND RESOURCE EFFICIENCY Enhanced Durability and Reduced Maintenance 4.406_1 Rodent proofing. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected 17-71 against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, a El 1:1 construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual_ At the time of final inspection, an operation and maintenance manual shall be provided to the building My occupant or owner. ENVIRONMENTAL Fireplaces 4.503.1 General. Install only a direct -vent sealed -combustion gas or sealed wood -burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical equipment during construction. Duct openings and other related air OX distribution component openings shall ae covered during construction. 4.504.2.1 Adhesives, sealants and caulks, Adhesives, sealants and caulks r-t Li shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be compliant with VOC limits. 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatngs shall be compliant with product weighted MIP Limits for RUC and other toxic I QX [� compounds. Pate 3 of � CalGreen_2014.doc revised OV1 i;14 4.504.2.4 Verification. Documentation shall be provided to verify that compliant VOC limit finish materials have been used. 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with �, ❑ VOC limits. 4.504.4 Resilient flooring systems. Eighty (80) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools (CHIPS) Low -emitting X❑ Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall Q comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete stab foundation. Required vapor retarders and capillary El breaks are also required to comply with CalGreen Section 4.505.2.1. 4.605.3 Moisture content of building materials. Moisture content of building materials used in wall and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans, Exhaust fans which tenninate outside the building are provided in every bathroom. Environmental Comfort 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS Qualifications 702.1 Installer training. HVAC system installers are trained and certified in the proper installation of HVAC systems. 702.2 Special inspection. ; he Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the 0 Q discipline they inspect and verify. Verifications 703.1 Documentation. Verification of compliance with CALGreen may include construction documents, plans. specifications, builder or installer certification. inspection reports, or other methods acceptable to the enforcing agency which show substantial conformance Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen 2014.doc revised Oh15/14 Project Name: Project Address: Project, Description: CALGREEN SIGNATURE DECLARATIONS Vadhia addition 1479 Poppy Way Cupertino; C. 95014 Addition and remodel SECTION 1 - DESIGN VERIFICATION Complete all lines of Section 1 — "Design Verification" and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2013 California Green Building Standards Code as adopte*Y ttlte Citv of Qxertino. Vwners bipature �VANIL< ✓A)t-4-1 f Owner's Name (Please Print) i - r� De, rof onal's Signa ure Design Profes nal's Name (Please Print) Sign to of License Professional responsible for CalGreen compliance rlua�e ydca ��'chl� ( �3606 Name of License Professional responsible for CalGreen compliance (Please Print) bo/Es�cad�o� Yl4-0o. cot" Email Address fo, icense Professional responsible for CalGreen compilance SECTION 2 - IMPLEMENTATION VERIFICATION 41 113f2014 Date dis1 Date /V. Date 4og - 6 ��-2/.5 Phone Complete, sign and submit the competed checklist. including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Pagc 5 of � CalGreen-2014.doc revised 01115114 BUILDING ENERGY ANALYSIS REPORT PROJECT: Vhadia Residence 1479 Poppy Way Cupertino, Ca Project Designer: M A K Design Grou CUPERTINQ Ei�w� Building Department REVIEWED NUR CODE CCMPL I>o1W, Reviewed By: �7� ✓ Z1 /41l' Report Prepared by: All Structural Consulting Engineers, Inc. 14503 Bercaw Ln San Jose, California 95124 408.496.0930 p�t .'y � 'C010 SUBMITTAL Job Number: � 1 14012 FF�4��� . 2 Date: 2/17/2014 The EnergyRro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Effic1 cy Standards. This program developed by EnergySoft, LLC—www.energysoft.com. EnerovPro 5.1 by EnerovSoft User Number. 5034 RunCode: 2014-02-17T10:13:06 ID: 14012 1 I TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 9 12 LEnergyPro 5.1 by EnergySofl Job Number: ID: 14012 User Number: 5034 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Vhadia Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 211712014 Project Address 1479 Poppy Way Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,364 Addition 483 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (fo Features see Part 2 of 5 Status Floor Wood Framed w/Crawl Space None 1,125 Existing Wall Wood Framed None 1,658 Existing Door Opaque Door None 20 Existing Roof Wood Framed Attic R-11 1,880 Existing Wall Wood Framed R-13 600 New Floor Wood Framed w/Crawl Space None 483 New Roof Wood Framed Attic R-30 0 New FENESTRATION U- Orientation Area(fo Factor Exterior SHGC Overhang Side -fins Shades Status Front (E) 96.0 0.710 0.73 none none Bug Screen Existing Right (N) 12.0 0.710 0.73 none none Bug Screen Existing Rear (W) 166.0 0.710 0.73 none none Bug Screen Existing Left (S) 16.0 0.390 0.37 none none Bug Screen Altered Skylight 0.8 0.390 0,29 none none None New Right (N) 32.0 0.390 0,37 none none Bug Screen New Rear (W) 96.0 0.390 0.37 none none Bug Screen New Front (E) 1.9 0.390 0.37 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by Energ Soft User Number.5034 RunCode: 2014-02-17T10:13:0 ID: 14012 Page 3 of 12 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Vhadia Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family 2 Existing+ Addition/Alteration Date 211712014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EnergyPro 5.1 by EnerqySoft User Number.5034 RunCode: 2014-02-17T10:13:0 ID. 14012 Pa e 4 of 12 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Vhadia Residence 1 ❑ Multi Family (21 Existing+ Addition/Alteration 211712014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV (kBtu/ft2 r) Space Heating 61.61 59.13 2.49 Space Cooling 51.88 41.32 10.56 Fans 20.82 17.84 2.98 Domestic Hot Water 16.25 16.25 0.00 Pumps 0.00 0.00 0.00 Totals 150,57 134,54 16.03 Percent Better Than Standard: 10.6 % BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 512 98 Fuel Available at Site: Natural Gas (S) 371 16 Raised Floor Area: 1,608 (VIO 1,080 262 Slab on Grade Area: 0 (N) 735 44 Average Ceiling Height: 8.0 Roof 1,881 1 Fenestration Average U-Factor: 0.60 TOTAL: 421 Average SHGC: 0.60 Fenestration/CFA Ratio: 17.8 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company All Structural Consulting Engineers, Inc. 14503 Bercaw Ln 2/17/2014 Address Name City/State/ZipCity/State/Zip San Jose, California 95124 Phone 408.496.0930 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company M A K Design Group LLC Address Name Mark Beyong City/State/Zip Phone n d License q Date EnergyPro 5.1 by EnenqySoft User Number: 5034 RunCode: 2014-02-17T10:13:0 ID. 14012 Pa e 5 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Vhadia Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 211712014 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Floor 1,125 0.097 None 0 180 Existing 4.4.1-A1 1 st Floor Wall 156 0.356 None 90 90 Existing 4.3.1-A1 1 st Floor Door 20 0.500 None 90 90 Existing 4.5.1-A4 1 st Floor Wall 120 0.356 1 None 90 90 Remove 4.3.1-A1 1 st Floor Door 20 0.500 None 90 90 Removec 4.5.1-A4 1 st Floor Wall 266 0.356 None 0 90 Existing 4.3.1-A1 1 st Floor Wall 282 0.356 None 270 90 Existing 4.3.1-A1 1 st Floor Wall 282 0.356 None 270 90 Remove 4.3.1-A1 1 st Floor Wall 100 0.356 None 180 90 Existing 4.3.1-A1 1 st Floor Roof 1,124 0.079 R-11 270 0 Existing 4.2.1-A2 1 st Floor Wall 120 0.102 R-13 0 90 New 4.3.1-A3 1 st Floor Wail 64 0.102 R-13 180 90 New 4.3.1-A3 1 st Floor Wall 304 0.102 R-13 270 90 New 4.3.1-A3 1 st Floor Walt 112 0.102 R-13 0 90 New 4.3.1-A3 1 st Floor Floor 483 0.097 None 0 180 New 14.4.1-A1 1 st Floor Roof 0 0.031 R-30 0 0 New 14.2.1-A20 i st Floor FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 56.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear 1 st Floor 2 Window 32.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear 1 st Floor 3 Window 12.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear i st Floor 4 Window 118.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear i st Floor 5 Window 118.0 0.710 Default 0.73 Default 270 Removed Double Metal Clear i st Floor 6 Window 16.0 0.390 NFRC 0.37 NFRC 180 Altered Milgard Classic Low-E Vinyl 1 st Floor 7 Existing 0.710 Default 0.73 Default Double Metal Clear pre -altered for above 8 Skylight 0.8 0.390 NFRC 0.29 NFRC 2701 New Velux Comfort+(74) Lowe2/Arg 1 st Floor 9 Window 32.0 0.390 NFRC 0.37 NFRC 0 New Milgard Classic Low-E Vinyl 1 st Floor 10 Window 96.0 0.390 NFRC 0.37 NFRC 270 New Milgard Classic Low-E Vinyl 1 st Floor 11 Window 40.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear 2 nd Floor 12 Window 6.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear 2 nd Floor 13 Window 1.9 0.390 NFRC 0.37 NFRC 90 New Milgard Classic Low-E Vinyl 2 nd Floor 14 lWindow 48.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear 2 nd Floor (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 None 1.00 9 Screen 0.76 _Bug 10 Screen 0.76 _Bug 11 Screen 0.76 _Bug 12 Bug Screen 0.76 13 Screen 0.76 _Bug 14 Screen 0.76 _Bug EnergyPro 5.1 by Energysoft User Number: 5034 RunCode: 2014-02-17T10:13:0 ID. 14012 Pa e 6 of 12 CER,rIFICATE • Project Name Vhadia Residence Buil• • Type l•I Single Family ■ Addition Alone 0 Multi Family 10 Existing+ Addition/Alteration OPAQUE SU113FACE DETAILS Joint Appendix 4 Location/Comments FENESTRATION SURFACEDETAILS EXTERIOR SHADING DETAILS CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF-1 R Project Name Vhadia Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 211712014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area f Volume Year Built New Existing Altered Removed HVAC System 1st Floor 1,125 9,000 1964 Addition 1 st Floor 483 3,864 2 no Floor 756 6,048 1964 Tota1S 1 4831 1,8811 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Fumace 78% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Coolin Duct Location Duct R-Value Ducts Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ New 13 13 13 13 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas Kitchen Pipe Ins 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E N o- Hot Water Piping Length (ft)o °o Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty FHPw Plenum Outside Buried ❑ :::::#❑ E]❑ EnerqyPro 5.1 by EnerqvSoft User Number. 5034 RunCode: 2014-02-17T10:13:0 ID, 14012 Page 8 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1R Project Name Vhadia Residence Date 211712014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-1 1 1 (a). 1 17: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. *§150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number. 5034 RunCode: 2014-02-17T10:13:06 ID: 14012 Page 9 of 12 iMAiNDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project iName Date Vhadia Residence 211712014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy Iuminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed Iuminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 1 50k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoff User Number. 5034 RunCode: 2014-02-17T10:13:06 ID. 14012 Page 10 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Vhadia Residence 211712014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 1 1. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to com I with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number., 5034 RunCode: 2014-02-17T10:13:06 ID 14012 Page 11 of 12