Loading...
B-2016-3220CITY OF CUPERTINO BUILDING PERMIT BUH.DINGADDRESS: CONTRACTOR: PERMIT NO: B-2016-3220 8019 PUMPKIN CT CUPERTINO, CA 95014-4902 (362 02 045) N90 CONSTRUCTION SAN JOSE, CA 95135 OWNER'S NAME: WOLFSON MARTIN DATE ISSUED: 12/06/2016 OWNER'S PHONE: 408-623-8477 PHONE NO: (408) 966-5268 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT ENFO: License Class J Lic. #906011 Contractor N90 CONSTRU TIQy Date 11 1 7 X BLDG X ELECT —PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing — MECH X RESIDENTIAL — COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: I hereby affirm under penalty of perjury one of the following two declarations: REMODEL KITCHEN (121 S.F.); REMODEL MASTER & HALL BATHS i. I have and will maintain a certificate of consent to self -insure for Worker's (80 S.F.); REPLACE 100 AND PANEL (& GROUND SYSTEM), SAME Compensation, as provided for by Section 3700 of the Labor Code, for the LOCATION performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurances as provided for by ection 3700 of the Labor Code, for the performance of the work for which this Permit is issued.. Sq. Ft Floor Area: Valuation: $48000.00 APPLICANT CRTIFI ATION certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize 362 02 045 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against PERMIT EXPIRES IF WORK IS NOT STARTED said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point WITHIN 180 DAYS OF PERMIT ISSUANCE OR source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signatur Date 12/06/2016 Issued by: ME OWNER-INTii,DTkizDECL Date:12/06/2016 RATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature ofApplicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 12/06/2016 I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. 1 have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued, maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the s. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous Worker's Compensation laws of California. If, atter making this certificate of air contaminants as defined by the Bay Area Air Quality Management District I exemption, I become subject to the Worker's Compensation provisions of the will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agen ' APPLICANT CERTIFICATION Date: 12/06/2016 I certify that I have read this application and state that the above information is �LuMG AGENCY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that ther i�onstruction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DF I RATION Code, Section 9.18. 1 understand my plans shall be used as public records. Signature Date 12/06/2016 Licensed Professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION EM 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 CUPERTINO (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino orq ❑ NEW CONSTRUCTION © ADDITION ❑ ALTERATION / TI ❑ REVISION /DEF D 2-016, pE -7 I# ZO PROJECT ADDRESS ' / APN # OWNERNAME 3 l PHONE IL STREET ADDRESS CIO', STATE,2*,y p L�3 1 �J ,9J O L � FAX CONTACT N STRFpElr,4�DS .LICENSE NUMBER ®� SGML `"`�� L �1 E-MAIL C ATE, ZIP FIs CA Q S) W FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT OCONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑. DEVELOPER [01 TENANT. CON TO ICENSE TYPE BUS. LIC # ARCHITECT/ENGINEERNAMt .LICENSE NUMBER BUS. LIC # COMPANYNAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK % Of EXISTING USEPROPOSED S{E�_,� CONSTR TYPE #STORIES - -- USE i AVSTG NEW FLOOR b DEMO TOTAL TYPE OCC. SQ.FT: I �. '1,2 bD AREA NET AREA BATF0OM �_. KITCHEN i L ARRA 4'� •. REMOD 'A�E. OTHER L.s ' - ? REMODEL ARE - 0 -,t - ------ # DWELLING UNITS: ISA SECOND UNIT ❑ YES SECOND STORY ❑ YEs BEING ADDED? El NO ADDITION? E] NO PRE -APPLICATION ❑ YES IF YES, PROVIDE. COPY OF IS THE BLDG AN ❑YES PLANNING APPL# E] NO PLANNING APPROVAL LETTER EICHLER. HOME? ❑ r By Iny signature below, I certify to each of the following: I am the property owner or authorized agent to act erty o / application and the information I have provided is correct. I have read the Description of Work and ve ' :It I urate, ee to c ordinances and state laws relating to building construction. I authorize representatives of Cupertino t er-rdeentified rc Signature of Applicant/Agent: Date: i2 i SUPPLEMENTAL TIONREQUIRED New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. —Commercial Bldgs: Provide a completed Hazardous Materials Disclosure form if any Hazardous Materials are being used as part of this project. _ Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. VALUATION ($) lalf. I have read this th all applicable local for ins ion purposes. BldgApp_201 Ldoc revised 06121111 Cu Ass�.sor's Parcel Number: fume of 0Wner: i Contact Person: Project Address: Phone;. Scope of Work, ►' Code Editions: 2013 Callfornla Residential Code 2013 California Plumbing Code cupet � 2013 Cafifornia Mechanleal Code -t ufl�r�q Dtq 2023 California Electrical Code QC 0 �lf� ►1f 2013 California Energy Code '�Vl C, Eneray Code mandatory lighting maasures: Revi y�yr E ��41 rj 1. All permanently Installed high affloacy luminaires shall be switched separately from low efficacy luminaires. (150(kfty &Y. Wi g_ 1 1ANC& 2, m rmsnently installed, lighting In Kitchens shall be high efticaey. luminaires. Up to 50% of the Wattage of permanently Installed lighttng -��hs-maybe In fights that ara not high eflfcaey, (150(kX8)) Aft Ii a ov Ml %.5 ----1 %15 _--- 0 f f 0, 10r/0 p! c_ ,e r lJ _ .. -. .�.3�� Vit• f 41� EXISTING KITCHEN FLOOR PLAN Multi otes' 1. Faucets In kitchens, wet bars, lavatories, laundry sinks, etc shall have a water flow not to exceed 1.8 gallons per minute Q 60 psi. (CPC 403,6) Electrical Rates: 2. The Installation of smoke -alarms in all of the following areas shall be provided: (R314.3) a, On the calling or wall outside of each separate sleeping area In the immediate vlolnity of bedrooms. b. 1n each room used for sleeping purposes. c. In each story within a dwelling unit, including basements but not Including craw; spaces and uninhabitable atfics, 3. Approved carbon monoxide alarms shall be instelled outside of each separate sleeping area In the Immediate vicinity of the bedrooms and an every level including basements 1n dwelling units that have fuel -fired appliances or attached garages. (CRC R31W ) 4. A minimum of two 20 amp small appliance branch clrcults shall be provided for an recepiacle outlets In the kitchen, dining room, pantry, or other similar areas. (CEO 210.i1(C)(1)) 6. At least one 20 amp branch circuit shall be provided to supply bathroom receptacle outlets, Such clreults shall have no other outlets. (CEC 210,11(0)(3)). 6, In every dwelling unit, fixed appliances such as food waste grinders, dishwashers, washing machines, dryers, laundry fray looatlons, built-in refrigerators or freezers, furnaces, AC urdts, built-in heaters or any other fixed appliance with a motor of 1/4 h.p. or larger shall be on a separate 20 amp: branch circuit. 7. All receptacles in bathrooms, garages, accessory buildings, outdoors, crawl spaces, unflnlshed basements, kitchens (where receptacles serve counter top surfaces). laundry, utility, wet bar sinks (within 6 feet of the edge of the sink), shall have ground -fault circuit Interrupter (GFCI) protection. (CEG 210.8(A)) 8. In all areas specified In 210.52, all non-locking type 125 -volt, 16- and 20• ampere receptacles shall be listed tamper-resistant receptacles, (CEC 406.12) icling [)ppr9fnent �'ODE COMPLIANCE ViOwed By ( M A -r\ 'o)"A PROPOSED KITCHEN FLOOR PLAN Assessor's Parcel Number: 3 p Z— 02— Narne of Owner: M*4v",. L1.141 /V'\ Contact Person: _ Phone; Project Address: Scope of Work: Code Editions: 2013 California Residential Code 2013 Callfornia Plumbing Code 2013 California Mechanical Code 2013 California Electrical Code 2013 California Energy Code ea anlca Notes: 1. Bathroom vents shall terminate not less than 3 feet from openings and property lines, (CthC 504,1) 01-s®E BnergyCode Mandatory Measures, 1. All permansndy installed high efficacy luminaires shall be switched separately from low efficacy luminaires (150(k)(7)) 2. Permanently Installed luminaires In bathrooms shall be high efi1oacy luminaires OR are controlled by an. occupant- sensors(s) certlled to comply with Section 119 That does not turn on automatically or have an always on option. (t 50(k)(10)) 0,4C, IRA-i� jf-c;� b- V-,%. 04AIN . V ped "'CIO GOD t--- 5 km e- . EXISTING BATHROOM FLOOR PLAN EjumbinNotes: 1, Yvater closets shall have an average water consumption of not more than 1.28 gallons per effective flush, (CPC 403.2) 2. Shower heads shall have a water flow not exceed 2.0 gallons per minuies @ 80 psl, (CPC 409,2) 3. Faucets. In lavatories shall have a water fimv not exceed 1,5 gallons per minutes @ 60 psl and shall not be less than X gallons per minutes at 20 psi, (CPC403.6) 4. Shower stalls shall have a clear Interior finish area of 7.1 sq,ft and be able to accommodate a minimum 30 Inch circle at the threshold level, mese clearances shall°be maintained up to a height of 70 Inches able the shower drain. (CPO 448.6) S. Shower compartments and walls above bathtubs with Installed shower heads shell be finished NL.* a smooth, nonabsorbent surface to a height not less than 72 Inches (6ft). (CRC 8307.2) 6. The maximum hot water temperature discharging from the bathtub, shower and whirlpool bathtub filler shat€ be limited to 120 d agrees Fahrenheit. The water heater thermostat shall not be considered a control for meeting this provision. (CPC 409.4 & 408,3) 7, Water closet shall be set minimum 16 inches from Its cenier to a side wall or obstruction and 24 Inch clearance In front of water closet, (CPC 402,5) Electrical Notes, 1. The Installation of smoke alarms In all of the following areas shall be provided: (8314.3) a, On the ceiling or wall outside of each separate sleeping area In the Immedlate vicinity of bedrooms. b. In each room used for aeping purposes, c. In each story within a dwelling unit, Including basements but not Including crawl spaces and uninhabitable attics, 2. Approved carbon monoxide alarms shall be Installed outside of each separate sleeping area In the Immediate victnity of the bedrooms and on every level iroaudingi basements In dwalltng units that have fuel -fired appliances or attached garages. (CRC R315,1) $. At least one 20 amp branch circuit shall be provided to supply bathroom receptacle outlets. Such circuits shall have no other outlets, (CEC 210.11(C)(3)) 4. All receptacles In bathrooms, garages, accessory buildings, outdoors, crawl spaces, unfinished basements, klichens (where receptacles serve counter top surfaces), Iaundry, utility, wet bar sinks (within 6 feet of the edge of the slnk), shat! have ground fault oiroul( tnterrupier (GFCI) protection. (CEC 21 C.8) 5. In all areas spedfied In 210.52, 911125 -volt, 15• and 20- ampere receptacles shall be listed tamper-resistant receptacles. (CEC 406.111 PROPOSED BATHROOM FLOOR PLAN