Loading...
13080147CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10613 N STELLING RD CONTRACTOR: GINO'S CONSTRUCTION PERMIT NO: 13080147 OWNER'S NAME: VIKAS NAYAR P 0 BOX 110057 DATE ISSUED: 10/15/2013 OWNER'S PHONE: 4084407914 CAMPBELL, CA 95011 PHONE NO: (408) 963-7373 LICENSED CONTRACTOR'S DECLARATION. JOB DESCRIPTION: RESIDENTIAL 11 COMMERCIALE] License Class ic. # ink CONSTRUCT A 249 SQ FT ONE STORY ADDITION Contractor Date as I hereby affirm that I aTli4cieired un e provisions 4 Chapter 9 (commencing with Sect 000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $12500 erformance of the work for which this permit is issued., have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 32608052.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITIHN 18 OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ST CALLED SF LAST CALLED PMSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said C in consequence of th City 1"u V. issu v: Additionally, granti �P,�h�is_permit. Additionally, the applicantunderstands and will comply ap uum" u' r t wi I non -point source regulations per the Cupertino Municipal Code, Section t so �o regulations non -point RE -ROOFS: installed. N is 9.1 g Signatur Date)(( All roofs shall be inspected prior to any roofing material being a roof installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner.of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Munici al Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this the Health & Safety Code, Sections 25510 , 5533, an 25534. nU Owner or authorized agentcA .1 Date.\ permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AG CY Compensation laws of California. if, after making this certificate of exemption, I . become subjectto the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address - I certify that I have read this application and state that the above. information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date PERMIT APPLICATION CONSTRUCTION � I FEE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 . FAX (408) 777-3333 • buildingacapertmo.org CupERTmd M ............... ..........�..,.,.�. ) ' ......•.-.mar n n t mcn -rrnl r i mr �I DRvrCInTT / r1FFFRRFTI 0TZI(11NAI. PF.RMIT # u ,.., .. �....... ........ate.-... o.�.-�.•----___"_. ,� /� PROJECT ADDRESS Q Por s 7 1� ( l it A j p(� P Y 1 1 1} _ _... APN # � — ^^Oy ll+ +� OWNER NAME 1 'AS PHONE [��U 1 -1 EMAIL V r KAS: 1,4M/A&6iI E 1 ML C STREET ADDRESS e ]] -•�' 1 6l l CITY, STATE, ZIP g- p `®p �r [� c�.l�le K,f I L.l"{) CONTACT NAME 1 •r[ A g� ! r $P ( > �"TC ",I � � PHONE ( p 0 tI "1 q o -1914E71 6`_i`i S, ( F1 ° _� I713111OU`T IL'C2� `-Z[IP STREET ADDRESS p1(`1 ` j !F'E i I � 1 f. CJ � e VV(v? C3 E G�-'=-1 i �i "l Ir\ N CITY, STATE, � � y � ,� 9 � o g � t FAX OWNER ❑ OWNER -BUILDER 11OWNER AGENT ❑ CONTRACTOR El CONTRACTOR AGENT El ARCHITECT 11 ENGINEER El DEVELOPER ❑'TENANT CONTRACTOR NAME , �j [�eVL� �l/v7 LICENSE NUMBER �i2,/'I� G-r•� G/ LICENSE TYPE BUS. LIC # COMPANY NAME STREET ADDRESS,�7�,.. CITY;'STATE, ZIP %1� PHONE n F� ARCHITECTBNGINEERNAME LICENSE NUMBER �/ BUS- LIC COMPANY NAME E-MAIL AIL ` a Q]G (jl"'T!►n y� y:C+.4�?�1;� FAX f+3 STREET ADDRESS •� � Gtr q s�Q -� t CITY STATE, ZIP °���1 G PHONE /�.� � r_ "% li !i j i 4 ! o � mus r 14f ®c DESCRIPTION OF WORK Z ti p r q J ra'�n .. vi-cs tis" P,,,, Cff VP VP EXISTINGUSE. PROPOSED USE CONSTR TYPE # STORIES USE TYPE OCC. - SQXT.. VALUATION ($) EXISTG AREA NEW FLOOR AREA f?..i DEMO AREA. TOTAL NET AREA _ ' BATHROOM .'. REMODEL AREA KTTGCHEN REMODEL AREA OTHER REMODEL AREA a_ PORCH AREA - DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DUETACH ❑ ATTACH #DWELLINGUNITS: LSA SECOND UNIT []YES SECOND STORY ❑YES - BEINGADDED? ❑NO ADDITION? []NO TOTAL VALUATIONpppr PRE -APPLICATION ❑YES IF YES, PROVIDE COPY OF I9 THE BLDG AN❑YES - _ - r F PLANNING APPL # ❑ NO PLANNINGAPPROVAL LETTER EICHLER HOME? Q NO - s _ +� By my signature below, I certify to each of the following: I am the property owner or aut e to act on pr owner's behalf. I have read this I is correct. I have read the Description of Work and verify i i ate. I agree to comply with all applicable local application and the information have provided and state laws relating to bui dinCg construction. I authorize representatives of Cupertino to este a above -identified for inspection purposes. jproperty ordinances Date: � (20 1 /3 Signature of Applicant/Agent: 1 i dl SUPPLEMENTAL FORMATION RED Y ort ' pt+i w711 I i New SFD or Multifamily dwellings: Apply for deq.olition permit for f CImGDII�rIIr� j �H 46 rt _ existing building(s). Demolition permit is required prior to issuance of building permit for new building. E eivPr rev ' Commercial Bldgs: Provide a completed Hazardous Materials Disclosuresn TRD _ form if any Hazardous Materials are being used as part of this project. l4 p- of Planning Approval Letter or Meeting with Planning prior to t sTsnc _Copy submittal of Building Permit application. _ - � BldgApp_2011.doe revised 06/21/11 aim CITY OF CUPERTINO FEE ESTIMATOR RT7TT:nTNC n1V1QYn1V ` ADDRESS: 10613 N STELLLING RD TYPE OF CONSTR. DATE: 08/20/2013 REVIEWED BY: MELISSA APN: 326 08 052 BP#: / �,® v N R-3 (Custom) *VALUATION; $12,500 `PERMIT TYPE: Building Permit $1,059.00 PLAN CHECK TYPE: Addition PRIMARY SFD or DupleX USE: 2nd Unit? Yes No OTC? 0 Yes ENo PENTAMATION PERMIT TYPE: 1 R3SFDADD WORK I ADDITION OF 249 S.F. TO ADD N BEDROOM & EXTEND E BATHROOM SCOPE 0,0 hrs $0.00 OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) 11-8,111-B,IV,V-B 249 $1,059.00 IADDPLCK $1,026.00 IADDINSP PME Plan Check: $0.00 Permit Fee: $1,026.00 Suppl. Insp. Feer Reg. 0 OTJ 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction .T'eiy: TOTALS: 249 $1,059.00 _ $1,026.00 E) Work Without Permit? 0 Yes 0 No i1ech. Plan £.`heck Phimb. Pkin Cheek QTY/FEE Dec. Plan Check i'L e.Cll. -wit 1"G'C:: Plumb, Permit Fc?,,-: 1 ZsC. Permit }`ee: Olhertltech. Insp. Other Plumb Inst;. Olhe r 1:lec. Insp. tech. Insp. Fee Plunib. Ins{). Fee: Flec. Insp. Fee: 1tvui.n z nts esumate aces not inctuae fees aue to other Departments (i.e. Planning, Public Works, Lire, Sanitary Sewer District, .School //Ivtrirt Pt('-)- / hover fOO.Q an, hacod n" flfa sl.,. n,...s .. ,..l.l..: 1l :-,C- FEE ITEMS (Fee Resolution 11-053 Ef. .. 7/U12� FEE QTY/FEE MISC ITEMS Plan Check Fee: $1,059.00 Select a Misc Bldg/Structure or Element of a Building Suppl. PC Fee: Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $1,026.00 Suppl. Insp. Feer Reg. 0 OTJ 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction .T'eiy: A(Iministrative I%ee: E) Work Without Permit? 0 Yes 0 No $0.00 Advanced Planning Fee: IPLLONGR $34.86 Select a Non -Residential Building or Structure E) 0 A Crrrv>el Documentalion fees: Strong- Motion Fee: IBSEISMICR $1.25 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 S TOTAL $2,122.11 $0.00 - - _ -Tc TA a $2,122.11 Revised: 07/01/2013 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 CONTRACTOR / SUBCONTRACTOR LIST JOB ADDRESS: a 06 PERMIT OWNER'S NAME: )�J(Auiovl_j PHONE GENERAL CONTRACTOR: BUSINESS LICENSE # ADDRESS: d %� CITY/ZIPCODE: *Our municipal code. equires aft businesses workingAn the city to have a City of Cupertino lAsiness license. . NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTIONS) WILL BE SCHEDULED UNTIL,THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. ' I am not using any subcontractors: x Signature Date Please check applicable subcontractors and_ complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating X Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Owner / Date BUILDING ENERGYANALYSIS REPORT o3e�oe5�� PROJECT: REAR ADDITION +EXISTING 10613 N.STELLING ROAD CUPERTINO, CA 94014 Project Designer: J&M Design 1005 West Eighth Street Stockton , CA 95206 (650) 330-0328 A s Report Prepared by: Jose Jimenez J&M Design 1005 W. 8th Street r Stockton, CA 95206, " 4vlo (650) 793-1491 y G z CIO t Vigo Job Number: Date: OCT 02 2013 9/30/2013'---� The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has app5oval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 5.1 by Ener Soft User Number.- 6555 RunCode: 2013-09-30T20:59:47� ID: TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 EnergyPro 5.1 by EnergySoft Job Number:. ID: User Number: 6555 PERFORMANCE CERTIFICATE: Residential Part 1 `of 5 CF -111 Project Name REAR ADDITION + EXISTING Building Type ® Single Family 13 Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 9/30/2013 Project Address 10613 N. STELLING ROAD CUPERTINO California Energy Climate Zone CA Climate Zone 04 Total Gond. Floor Area 2,966 Addition 249 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ® Yes ® No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for'details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Wall Wood Framed R-13 213 New Roof Wood Framed Attic R-30 249 New Slab Unheated Slab -on -Grade None 249 Perim = 47' New Wall Wood Framed R-13 116 Altered Wall Wood framed R-13 2;034 Existing Door Opaque Door None 37 Existing Slab Unheated Slab -on -Grade None 1,337 Perim = 137' Existing Roof Wood Framed Attic R-19 1,692 Existing FENESTRATION U- Exterior Orientation' Area Factor SHGC Overhang Sidefins Shades Status Rear (M 50.0 0.390 0.37 none none Bug Screen New Front (E) 18.0 0.510 0.61 none none Bug Screen Removed Rear (lAq 129.0 0.510 0.61 none none Bug Screen Existing Front (E) 161.0 0.510 0.61' none none Bug Screen Existing Left (S) 18.0 0.510 0.61 . none none Bug Screen Existing Right (N) 33.0 0.510 0.61 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Roof Ins 8.0 Existing WATER HEATING `Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 b .Ener Soff User Number. 6555 RunCode: 2013-09-30T20.59 47 1D: Pa e 3 of 12 PERFORMANCE CERTIFICATE. Residential (Part 2 of 5) CF -1R Project Name Building Type 0 Single Family ❑ Addition Alone i Date REAR ADDITION + EXISTING � Q Multi Family ® Existing+. AdditionlAlteration 1913012013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this. checklist. These items rewire special written justification and documentation, and special verification to be used .with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation. submitted. The HVAC System Carrier 58MTBfl0140-1 S does not include a cooling system, field verification is not necessary. HEFTS REQUIRED VERIFICATION Items in this section require field testing and/or verification.by a certified HERS Rater. The inspector must receive a completed GF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number. 6555 RunCode. 2073-09 3AT20:59:47 lli_ " pac le 4 of 12 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date REAR ADD/TION + EXISTING ❑ Multi Family m Existing+ Addition/Alteration 9/30/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 21.87 22.16 -0.29 Space Cooling 8.55 6.99 1.56 Fans 5.26 4.91 0.35 Domestic Hot Water 13.32 13.32 0;00 Pumps 0.00 0.00 0.00 Totals 49:00 47.38 1.62 Percent Better Than Standard: 3.3 BUILDING COMPLIES -'NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation:. (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 742- 161 Fuel Available at Site: Nature/ Gas (S) 655 18 Raised Floor Area: o _ (VL9 739 179 Slab on Grade Area: 1,586 (N) 655 33 Average Ceiling Height: 8.0 Root 1,941 0 Fenestration. Average U -Factor: 0.49 TOTAL: 391 Average SHGC: 0.58 Fenestration/CFA Ratio: 13.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company J&M Design �9,/'JO//2�013 Address 1005 W. 8th Street Name Jose Jimenez City/State/Zip Stockton, CA 95206 Phone (650) 793-1491 /---Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this'set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and, with any other calculations submitted with this permit application, and recognizes that compliance using. duct design, duct sealing; verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company J&M Design Address 1005 West Eighth Street Name Jose Jimenez ; City%State/Zip Stockton, CA 95206 Phone (650) 330-0328 Signed License =EnerqvPro 5.1 by Ener Soft User Number: 6555 RunCode: 2013-09-30T20.59:47 /D: Pas 5.012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name REAR ADDITION + EXISTING Building Type ® Single Family ❑ Addition Alone o Multi Family to Existing+ Addition/Alteration Date 119/30/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Wail 101 0.102 R-13 180 90 New 4.3.1: A3 Addition and existing Wall 112 0.102 R-13 270 90 New 4.3.1 A3 Addition and existin Roof 249 0.031 R-30 0 0 New 4.2.1-A20 Addition and existin Slab 249 0.730 None 0 _ 180 New 4.4.7-A1 Addition and existing Wall 116 0.102 R-13 90 90 Altered 4.3.1-A3(E=4.3.1-A3) Addition and existing Wall 258 0.102 R-13 180 90 Existing 4.3.1-A3 Addition and existing Door 17 0.217 None• 180 90 Existing 4.5.1-A4 Addition and existing we// 140 0.102 R-13 270 90 Existing 4.3.1 A3 Addition and existing Wall 127 0.102 R-13 90 90 Existing 4.3.1-A3 Addition and existing Door 20 0.217 None 90 90 Existing 4.5.1 A4 Addition and existin Wall 376 0.102 R-13 0 90 Existing 4.3.1 A3 Addition and existing Slab 1,337 0.730 None 0 180 Existin 4.4.7 Al Addition and existing Roof 312 0.049 R-19 0 0 Existing 4.2.1-A4 Addition and existing Wall 261 0.102 R-13 180 90 Existing 4.3.1-A3 Addition and existing Wall 1 308 0.102 R-13 270 90 Existing 4.3.1 A3 Addition and existing Walt 1 318 0.102 R-13 90 90 Existing 4.3.1-A3 JAddition and existing FENESTRATION SURFACE DETAILS ID Type Area 1 -11 -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 20.0 0.390 NFRC 0.37 NFRC 270 New Low -E Vinyl Addition and existing 2 Window 30.0 0.390 NFRC 0.37 NFRC 270 New Low -E Vinyl Addition and existing 3 Window 18.0 0.510 NFRC 0.61 NFRC 90 Removed Vin f/Clear Addition and existing 4 Window 60.0 0.510 NFRC 0.61 NFRC 270 Existing Vinyl/Clear Addition and existing 5 Window 102.0 0.510 NFRC 0.61 NFRC 90 Existing Vinyl/Clear Addition and existing 6 Window 18.0 0.510 NFRC 0:61 NFRC 180 Existing VinyllClear Addition and existing 7 Window 69.0 0.510 NFRC 0.61 NFRC 270 Existing VinyllClear Addition and existing 8 Window 59.0 0.510 NFRC 0.61 NFRC 90 Existing VinyllClear Addition and existing 9 Window 33.0 0.510 NFRC 0.61 NFRC 0 Existing VinyllClear Addition and existing (1) U -Factor Type: 116-A =Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hgt7 Wd Ove hanq Len H t LExt RExt Left Fin Right Fin Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6565 RunCode: 2013-09-30720:59:47 ID: Page 6 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1R Project Name REAR ADDITION + EXISTING Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 9/30/2013. BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC System Proposed Add. @ First Floor 249 1,992 Existing First Floor 1,337 10,696 1992 Existing Second Floor 1,380 111-040,1992 Totals 249 2,717 0 .- 0 HVAC SYSTEMS _ System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace ' 80% AFUE No Cooling 13.0 -SEER Setback Existing HVAC DISTRIBUTION System Nam_ a Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC System Ducted Ducted Attic, Roof Ins 8.0 ❑ Existing El WATER HEATING SYSTEMS System Name Qty. _ Type Distribution Rated Input Btuh Tank . Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas Kitchen Pipe Ins 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING _ Control Hot Water Piping Length ft c ¢ _ System Name ' Pipe Length Pipe Diameter lnsul. Thick. Qt .' HP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number., 6555 RunCode: 2013-09-30T20:59:47 ID: Page 8 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 " MF -1 R Project Name REAR ADDITION + EXISTING - Date 9/30/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of, the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with tans. Building Envelope Measures: §116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). §117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a :`Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value: *§150(c): Minimum R-13 insulation in wood -frame wall or equivalent LI -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent L1 -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no qreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. fire laces, Decorative Gas Appliances and Gas Lo Measures: 150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l S: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and,the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated -appliances are certified, by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release, valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply 'voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. 150(i): Heatin systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1, B:. Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. , §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of _ recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and E nation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table' 123-A. '4150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. , §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in .conditioned s ace. 7-- §150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Ener4yPro5.?. by EnergySoft User Number. 6555 RunCode: 2013-09-30T20:59:47 ID: Page 9 of 12 ;; MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3) MF -1 R Project Name Date REAR ADDITION + EXISTING 1913012013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603,- 604, 605 and Standard 6-5; supply -air and return -air ducts and pl enums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal oDenings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §1 50(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaustfan systems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, -including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause de -gradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(0); All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or as heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems ore ui ment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §1 50(k)2. §150(k)3: The wattage of permanently installed luminaires shall bedetermined as specified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §1 50(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or, exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed fighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyProal by EnergySoft User Number: 6555 RunCode: 2013-09-30T20.59W ID: Page 10 of 12 .4, MANDATORY MEASURES SUMMARY: Residential (Page 3 o 3 MF -1R Project Name _ Date REAR ADDITION + EXISTING 1913012013 §150(k)10:' Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119: EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13 Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (ENCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)l3 may be controlled by,a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed` luminaires in.or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code=need not be hic ih efficacy" luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130,132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130,131, 134, and 146. §150(k)i 6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number. 6555 RunCode:2013-09-30T20:59 47 ID: Page 11 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date REAR ADDITION + EXISTING 9/30/2013 System Name HVAC System Floor Area 2,966 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,514 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 61,000 32,041 1,960 744 36,771 Total Output (Btuh) 61,000 0 Output Btuh/s ft 20.6 942 1,348 Cooling System 0 0 Output per System 0 0 O 0 0 Total Output Btuh 0 0 1,960 0 Total Output (Tons) 0.0 942 1,348 Total Output (Btuh/s ft) 0.0 Total Out ut- s ft/Ton 0.0 33,926 39,467 Air System CFM per System 1,175 HVAC EQUIPMENT SELECTION Airflow cfm 1,175 Carrier58MTB00100-16 0 0 61,000 Airflow cfm/s ft 0.40 Total Adjusted System Output 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 61,000 Aug 3 PM Jan 1 AM Airflow cfm/Ton) 0.0 Outside Air (%) 0.0% Outside Air (cfm/ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 28 OF 67 OF 67 OF 115 °F Outside Air --- -- 0 cfm Supply Fan Heating Coil 114 OF AL 1,175 cfm ROOM , 67 OF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time Of Coolie Peak 88 / 68 OF 76 J 62 OF 76162 OF 55 / 54 OF Outside Air 0 cfm Supply Fan Cooling Coil 56154 OF 1,175 cfm 46.4% ROOM... 76 / 62 OF 75162 OF EnergyPro 5.9 by EnergySoft User Number. 6555 RunCode: 2013-09-30T20:59.'47 ID: Page 12 of 12 .-TATOW-M-01 SPECIALINSPEOTTION.S., &I Z' E- M 2.- 10 CM E g CUPERTINU�nO il 6;10 e� Xv, 41 ml :T" lz�l f cz 4`P! `7 -'A IZZIN -4,' EN'Ui E 4 i Q, a 7h7 m I.;=le atgalve�l Fur de Ea'''SpE6 ar., ml, ItE!i, il _Zp a -:V, m;;F�,�-,,ormcrza -Anv clatlav%s2z,. 1R_� Z�, fze, rip" �-Ml C�mzl I N3,17 - Sat, - ten- co u azxt 1� t frs E -A if il 2-:-1 Er'l L 7 -77 F 7r®r, Fel ,=r.-C-'eali 2013 iln zu i -_"T rNNM7'S'-: Lin 7t -a -By��z VITC�S�� or, 'lt�s C�m!ST 14 t rorz, El On Merr-'z, n'ss a ff'e 7j E-3 ;Pr -r "Iza, CUPERTWO 1113uilding,_ epartment OCT I IAS OFFICE COPY LST OF SPECIAL INS PEC74IONGENC-F WI _ bs# ,,. t.uats,� !N-'. iV. to zf:a. = uta. -"�.' 'A�li 24 n7iMs 172y s:- :C A- z .: V! ZPa. #.g1 VERIFICATION AND INSPECTIONC p REFERENCED IBC STANDARD REFERENCE INSPECTION OF CONCRETE 1. ❑ Inspection of reinforcing steel, including prestressing --- X ACI 318: 3.5, 7.1-7.7 1913.4 - tendons and placement. 2. q Inspection of reinforcing steel welding in accordance AWS D1.4 ACI 318: with Table 1704.3 Item 5b. 3.5.2 - 3. ❑ Inspection of bolts to be installed in concrete prior to and during placement of concrete where allowable X _ ACI 318: 8.1.3, 1911.5, 1912.1 Loads have been increased or where strength design 21.2.8 is used. 4. ❑ Inspection of anchors installed in hardened concrete. --- X ACI 318: 1912.1 5. ❑ Verifying use of required design mix. 1904.2.2,1913.2, --- X ACI 318: 1913.3 6. ❑ At time fresh concrete is sampled to fabricate ASTM C 172 specimens for strength tests, perform slump and air X --- ASTM C 31 1913.10 content tests and determine the temperature of the concrete. ACI 318: 5.6, 5.8 7. ❑ Inspection of concrete and shotcrete placement for X --- ACI 318: 59 5.10 . 510 1913.6, 1913.7, proper application techniques. 1913.8 8. ❑ Inspection for maintenance of specified curing _-- X ACI 318: 5.11-5.13 1913.9 temperature and techniques. 9. Inspection of prestressed concrete: Application of prestressing forces. X --- ACI 318: 18.20 ❑ Grouting of bonded prestressing tendons in the X --- ACI 318: 18.18.4 seismic force -resisting system. 10. ❑ Erection of precast concrete members. --- X ACI 318: Ch. 16 --- 11. ❑ Verification of in-situ concrete strength, prior to stressing of tendons in posttensioned concrete and --- X ACI 318: 6.2 --- prior to removal of shores and forms from beams and structural slabs. 12. ❑ Inspect formwork for shape, location, and dimensions --- X ACI 318: 6.6.1 --- of the concrete member being formed. 13:`� Bolts Installed in Existing Masonry or Concretes=��� ❑ Direct tension testing of existing anchors. --- X See ICC ES Reports form special inspection requirements for proprietary ❑ Direct tension testing of new bolts. --- X El Torque testing of new bolts. --- X products ❑ Prequalification test for bolts and other types of X anchors. _ 14. ❑ Other: SpecialnspectionForm 2012. doe revised 09/06/12