Loading...
15010143CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10373 TORRE AVE CONTRACTOR: CIVIC CENTER PERMIT NO: 15010143 PROFESSIONAL GROUP OWNER'S NAME: CIVIC CENTER PROFESSIONAL GROUP 10373 TORRE AVE UNIT G DATE ISSUED: 10/29/2015 OWNER'S PHONE: 4082573031 CUPERTINO, CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ STE H-FOR DENTAL OFFICE-ENCLOSING EXISTING PATIO License Class Lie, # INTO ADDITIONAL TENANT SPACE (100 SQ FT). Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. l have and will maintain a certificate of consent to self-insure for Worker's Sq. Ft Floor Area: Valuation: $20000 Compensation, as provided for by Section 3700 of the Labor Code, for the APN Number: 36940020.10373 Occupancy Type: performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code; for the performance of the work for which this permit is issued. PERMIT EXPIRES IF WORK IS NOT STARTED APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is WITHIN 180 DAYS OF PERMIT ISSUANCE OR correct. I agree to comply with all city and county ordinances and state laws relating180 D L LLED INSPECTION. to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save A— indemnify and keep harmless the City of Cupertino against liabilities, judg C® 5 y: Date: costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code, Section 9.18. RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. I, as owner of the property, or my employees with wages as their sole HAZARDOUS MATERIALS DISCLOSURE compensation, will do the work, and the structure is not intended or offered for _ ale (Sec.7044, Business & Professions Code) owner of the property, am exclusively contracting with licensed contractors to I have read the hazardous materials requirements under Chapter 6.95 of the construct the project (Sec.7044, Business & Professions Code). California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & I hereby affirm under penalty of perjury one of the following three declarations: Safety Code, Section 25532(a) should I store or handle hazardous material. 1. 1 have and will maintain a Certificate of Consent to self-insure for Worker's Additionally, should I use equipment or devices which emit hazardous air Compensation, as provided for by Section 3700 of the Labor Code, for the contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the performance of the work for which this permit is issued. Health & Safety Code, Sections 25505, 25533, and 25534. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this wne r an or' ed agee. t t .permit is issued. Date: certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I I hereby affirm that there is a construction lending agency for the performance of work's become subject to the Worker's Compensation provisions of the Labor Code, I for which this permit is issued (Sec. 3097, Civ C.) must forthwith comply with such provisions or this permit shall be deemed Lender's Name revoked. Lender's Address APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is ARCHITECT'S DECLARATION correct. I agree to comply with all city and county ordinances and state laws relating I understand my plans shall be used as public records. to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save Licensed Professional indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non-point source re lations per the Cupertino Municipal Code, Section 9.18. to Date 1 �1 49/ Y3 CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 FAX (408) 777-3333 - buildingacupertino.orq CUPERTINO I I I INFW(Y1N.CTRTT(-TTnN F-1 AT)T)TTT(11,J I -I AT.TFRATHIN/TT FI RPVTSTC)N/T)F.PF.RRF.T) ORT(INNAT,PF.RMTT# a4 PROJECT ADDRESSAPN R _40 OWN,�E�RR�NAME -' - P ONE E-MAIL ST jREET A nnRFsS qr y� CITTY,, `STATE, ,ZZI.P.,� /' Q p - FAX v? CONTACT NAME PHONEE-MAIL P-z-or)'L .�l S *_9, 255' `� -5 10 Gol4 STREET ADDRESS l'O3 W 3 -� a CITY, STATE, ZIP C� =d CA l � 4jo-ri 4-14c,% FAX e� p �p � F9 7 �J ® 4 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT !KT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NA 714-13eIrnT 16�- LICENSE NUMBER LICENSE TYPE BUS. LIC 9 COMPANY NAME ++,,.� �^q �j-y7y��. , Fs Wr 61'�✓e G kv E-MAIL / ^T la -vi. 6 (LkV Q P_�e i C� STREET ADDRESS CITY, STATE, ZIP PHONE ARCHIT GINEERNAM LL��-- LICENSE NUMBER �y �( � BUS. LTC# L_ l e— t-- d1 V COMPANY NA E-MAIL FAX STREET ADDS CI i SP PHONE DESCRIPTION OF WORK efC_.k=%)er,2-_T = ,v EXISTING USE - PROPOSED USE CONSTRPE / # STORIES USE TYPE OCC. SQ.FT. VALUATION($) d �G D��lG? ' v EXIST( ?��/J,.ep NE DEMO ` TOTAL AREA ' I �,?FLOOR AREA _ AREA. NET i vv BATHROOM KITCHEN RREMODEL AREA REMODEL AREA DELAREA �ARITA_GARAGE PORCH AREA DECK AREA TOTAL DECK RCI .AREA: DETACH ❑ ATTACH 4 DWELLING UNITS: IS A SECOND UNIT ❑ YES - BEING ADDED? SECOND STORY ❑ YES ADDITION? Wo iVO PRE -APPLICATION' []YES IF YES, PROVIDE COPY --OF IS THE BLDG AN ❑YES RE.CEIVED,BY pM''� -�.,.,_ ,�. -- = TALV.ALUATION: PLANNING APPL 0 r_1 NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each of the following: I am the property owner or authorized agent to act o t roperty owner's behalf. I have read this and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local application ordinances and state laws relating to bui l gco true ` I&tho ze rg resentatives of Cupertino to enter the above -identified property for inspection purposes. �/ !�? ! 6i Signature of Applicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIRED' Rte,,,, PYANC73ECI- YP,E, New SFD Multifamily dwellings: Apply for demolition permit for p ad J],' s t GPLAN RE�IEiV ' or existing building(s). Demolition permit is required prior to issuance of building ox T> corTl.xER Permit for new building.> 603 xxs5s w LAT,mP Alt xEYIEw _ Commercial Bldas: Provide a completed Hazardous Materials Disclosure Materials being as of this t h ❑ sTANDXxD s+� r srt' pTIBI rcolt>zs form if any Hazardous are used part project. D I;4RGEi IRE DEPT i* a Copy of Planning Approval Letter or Meeting with Planning prior to 4 n v ❑ - SAlYIT�R3' SE\i'ERAISTHICT. _ submittal of Building Permit application. 1lIAAJOFt t£ BTdgApp_2011.doc revised 06121111 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION ADDRESS: -Torre Ave DATE: 0112612015 REVIEWED BY: Sean APN: BP#: h *VALUATION: $20,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration /Addition/ Repair PRIMARY PENTAMATION 1 GENCOM USE: Commercial Building PERMIT TYPE: WORK Enclosin existing patio into additional tenants ace 100 sq ft). SCOPE 11c=c,t. Plan Cpec:, 3 71hanb. Plara C heeA Flec..Plan {, nsck ; F x Plwrb, Perndf Fee: I lc,c. Perirat r'� e: vfi>cir. c t rui 1�>tz: 0"Ijsex 'W'dt. 1r. p, Other Pluirb In.S V. L J 01/ter I'k- °. Itssn. III....�JJJ i'hini7 hn ;, Fee,: 1 °lec. Insp.Fee: 1c:ch 'n�'1t_ Fee:t NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fare, Sanitary Sewer District, School District, etc.. These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l in o. FEE ITEMS (Fee Resolution 11-053 E . 711113) FEE QTY/FEE MISC ITEMS N $0 00 21 hours Plan Check, Hourly Plan Check Fee: Hourly Only. U. Yes Suppl. PC Fee: (j)Reg. 0 OT 0.0 hrs $0.00 $286.00 ISTPLNCK PME Plan Check: $0.00 Permit Fee: Hourly Only? ® Yes Q No $0.00 Suppl. Insp. Feer Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee:. $0.00 consiruction Tax: 'Mi ini, trat;ve Fe'e: Work Without Permit? 0 Yeses No $0.00 Advanced Planning Fee_ $0.00 C� hours Inspections 1,jx l lac} , tarn/ �1;r.,ri Fc�eS: $715.00 ISTINSP Inspection, Hourly Strong Motion Fee: 1BSE151vrrco $5.6 0 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUI?TALS BT : $6.60 $1,001.00 _ 611 R 0 IlE: I $1,007.60 Revised: 01/06/2015 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: 15010143 10373 TORRE AVE CUPERTINO CA 95014 (369 40 020) (COBE CONSTRUCTION INC) CAMPBELL, CA 95008 OWNER'S NAME: CIVIC CENTER PROFESSIONAL GROUP DATE ISSUED: 10/29/2015 OWNER'S PHONE: 408-257-3031 PHONE NO: 408-371-3400 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class a Lie. #1335122 Contractor ( COBE CONSTRUCTION INC ) Date 02/26/2016 —BLDG _ELECT _PLUMB MECH RESIDENTIAL _ COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: STE H-FOR DENTAL OFFICE-ENCLOSING EXISTING PATIO I hereby affirm under penalty of perjury one of the following two declarations: INTO ADDITIONAL TENANT SPACE (100 SQ FT). 1. 1 have and will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. �. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county 7/28/15 PERMIT APPLICATION EXTENDED TILL 10/25/15. ordinances and state laws relating to building construction, and hereby Sq. Ft Floor Area: Valuation: $20000.00 authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and APN Number: Occupancy Type: expenses which may accrue against said City in consequence of the 369 40 020 369 granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code, Section 9.18. PERMIT EXPIRES IF WORK IS NOT STARTED �-- Signature---�'�"� Date 02/26/2016 WITHIN 180 DAYS OF PERMIT ISSUANCE OR s ARATION 180 DAYS FROM LAST CALLED INSPECTION. OWNER-BUILDER DF I hereby affirm that I am exempt from the Contractor's License Law for one of the Issued by: MELISSA NAME following two reasons: Date: 02/26/2016 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered RE-ROOFS: for sale (Sec.7044, Business & Professions Code) All roofs shall be inspected prior to any roofing material being installed. If a roof is 2. I, as owner of the property, am exclusively contracting with licensed installed without first obtaining an inspection, I agree to remove all new materials for contractors to construct the project (Sec.7044, Business & Professions Code). inspection. I hereby affirm under penalty of perjury one of the following three declarations: t. I have and will maintain a Certificate of Consent to self-insure for Worker's Signature of Applicant: Compensation, as provided for by Section 3700 of the Labor Code, for the Date: 02/26/2016 performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE a. 1 certify that in the performance of the work for which this permit is issued, I I have read the hazardous materials requirements under Chapter of the shall not employ any person in any manner so as to become subject to the California Health &Safety Code, Sections 25505, 25533, and 25534.34. I will Worker's Compensation laws of California. If, after making this certificate of maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the exemption, I become subject to the Worker's Compensation provisions of the Health & Safety Code, Section 25532(a) should I store or handle hazardous Labor Code, I must forthwith comply with such provisions or this permit shall material. Additionally, should I use equipment or devices which emit hazardous be deemed revoked. air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and APPLICANT CERTIFICATION the Health & Safety Code, Sections 25505, 25533, and 25534. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws Owner or authorized agent: relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree Date: 02/26/2016 to save indemnify and keep harmless the City of Cupertino against liabilities, CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance judgments, costs, and expenses which may accrue against said City in of work's for which this permit is issued (Sec. 3097, Civ C.) consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulations per the Lender's Name Cupertino Municipal Code, Section 9.18. Lender's Address Signature Date 02/26/2016 ARCHITECT'S DECLARATION I understand my plans shall be used as public records. CUPERTINO CONTRACTOR / SUBCONTRACTOR LIST Building Department City Of Cupertino 10300 Ton-e.Avenue Cupertino, CA 05014-3255 lelLplione: X408-777-3228 Far: 408-777-3333 *Our municipal code requires all businesses working in the city to have a City of Cupert— hio business license. NO BUILDING FINAL, OR FINAL OCCUPANCY INSPECTION(S) WILL, BE SCHEDULED UNTIL, THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPE:RTINO BUSINESS LICENSE... I ani not using any subcontractors: Signature Please check applicable subcontractors and complete the following information: .Date V SUBCONTRACTOR BUSINESS NAMEBUSINESS LICENSE ##� Cabinets cry: Millwork Cement Finishing Electrical --.__ � U/YeA 6�a .... .... _.__.._... Excavation -_........___..___.___.._..._ .Fencing ...^.._... 'Flooring/ Carpeting Linoleum /Wood Glass / Glazing Heating Insulation ff� 6W7 Landscaping ____......�._—.. Lathing HMasonry Painting / Wallpaper ...._........ . Paving Plastering Plumbing Septic Tank- `�� � ry --- , __.._.sem 44Roofing ........_...__......_....__....,.. Sheet Metal - __._....__..__.. _ ...._.._ ' "-- -..—_.___......_ Sheet Rock — .._ --- Tile_ ....--._........_ 17 4-- caner / —Contractor Signature ---- ---.-.---.__._.. ate �K� i� t; CUPERTINO OWNER -BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 - build! noaecupertino. oro Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: I ES _:......APN. C BPS 36 Z — `�o -azd mor q wNER N Mi _ 0WN_EER� D z - bno DESCRIPTION OF WORK: ccivV We are providing you with an Ownet-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) t 1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner - Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 2. 1 understand, building permits are not required to be signed by property owners unless they are responsible for /�ttruction and are not hiring a licensed Contractor to assume this responsibility. 3. 1 understand as an "Owner -Builder" I am the responsible party of record on the -permit. I understand that I may rotect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her na a instead of my own. 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. f� 5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be / c Idered an "employer" under state and federal law. 1 6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. /7.tential 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 6. I understand as an Owner -Builder if 1 sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForm 2010.doc revised 04/14/10 ff-9. 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed A0. co 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I a t e party legally and financially responsible for proposed construction activity at the site address listed above. hL11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide yall applicable laws and requirements that govern Owner -Builders as well as employers. 12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information l have -provided on this form. License contractors are regulated bylaws designed to protect.the.public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. -Your only remedy against unlicensed Contractors maybe in civil court. it is also important for you -to understand that if an unlicensed Contractor or employee of that individual or firm is injured .while working on your property, you may held liable for damages. If - you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS: Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable toth ity may be required to be presented when the permit is issued to verify the property owners sLqn2tjre.If 14, Property Owner's Signature: Date -; 7,J9 -Zr - ------------------------------------------------------------------------------------------------------------------------------------------- -- (NOTE: The following Authorization Form is required to be completed by the property ov✓neronly when designating an agent of the property owner to apply for a construction permit for the Owner -Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. p Scope of Construction Project (or Description of Work).Z� IY1 dTl Pllc'�Q52c� �1C� Project Location or Address: )0_373 lc_ r-, alr, # Cu tan-0 (3+ ��r Name of Authorized Agent: Pd (m W"' (n l n (9 MaDW Tel No .408 Address of Authorized Agent:103 83 Tar -e (auc O --A C�ppr I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to e presen when the permit is issued to verify the property owner's signature. / Property Owner's Signature: Date: OwnerBuilderForm_2010.doc revised 04/14/10 2/26/16 10383 Torre Ave Suite I Cupertino, CA, 95014 Cupertino Dental Group To Whom it may concern, We pulled a permit in October as owner builder by mistake and at this time we would like to change it to Contractor with Cobe Construction. This dental practice uses both Suite I and H. Alex Pagonis DDS Cupertino Dental Group 408-257-3031 Please call if any concerns. FILE New 2x12 DF #2 ledger oD 3 2 16d at every stud ' 7 -6 - New class A roofing tile roof lJ to match (e); install over 30# felt Additional R-30 Insulation in rafters. Maintain 1" min airspace per CBC 1203.2 Attic vents above insulation Min. 96 sq. inches - (E) Parapet New 8" plywood w/ 8d @ 4" o.c. edge, 12" o.c. field Profile of (e) roof New 2x12 DF #2 Rafters @16" o.c. with solid blocking at mid -span New 6" HVAC duct 2x6 DF#2 ceiling joists @ 16" o.c. w/ R8 Insulation with blocking at mid -span and (5) 16d @ every rafter New 6" HVAC duct w/ R-8 insulation- j -- Existing HVAC system 2x6 ledger w/ joist J Continuous screen attic vents hangers and (2) Match (e); min. 96 sq in. - 16d @ every stud Existing Space 00 New R-30 fiberglas batt Lay -in ceiling insulation in new ceiling (e) bearing wall with shear panel New R-15 fiberglas batt New office insulation in new walls Revised East-West Section s BUILDING ENERGY ANALYSIS REPORT PROJECT: Cupertino Dental Group CFIVED I03%3. ---Torre Aver# APR 17 2015 Cupertino, CA 95014 L - Project Designer: Paul H. Fick Architect 550 Calero Ave San Jose, CA 95123 408-281-4400 Report Prepared by: Nicholas L Bignardi NR08-12-3847 FRI Energy Consultants, LLC sUBMITTAL 21 N. Harrison Ave, Suite 210 ##2 Campbell, CA 95008 408-866-1620 Job Number: 0150290 4/1D5/2COPYQFFscE The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 6.5 by EnergySoft User Number: 1315 ID: 0150290 1 9 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form ENV -01 -E Envelope Component Approach 3 Form ENV -02-E Fenestration Worksheet 7 Form ENV -MM Envelope Mandatory Measures 9 Form LTI-01-E Indoor Lighting 10 Form LTI-02-E Lighting Controls 15 Form LTI-03-E Indoor Lighting Power Allowance 18 Form MCH -01-E Mechanical Systems 21 Form MCH -02-E HVAC System Requirements 24 Form MCH -03-E Mechanical Ventilation and Reheat 26 Form MCH -04-E Required Acceptance Tests 28 STATE OF CALIFORNIA ENVELOPE COMPONENT APPROACH CEC-NRCC-ENV-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E Envelope Component Approach (Page 1 of 4) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 A. GENERAL INFORMATION 1 Project Location: 6 Compliance Method: m Component ❑ Unconditioned (file 5 10383 Torre Ave Suite I 7 Affidavit) 2 CA City and Zip Code: Cupertino, 95014 7 Building Front Orientation (deg or cardinal): 180 deg 3 Climate Zone: 4 8 Permitted Scope of Work 1 ❑ New Construction IZI Addition ❑ Alteration 4 Total Conditioned Floor 105 9 Building Type(s) ❑ Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room Proposed U -Factor Area: Comments 1 5 ❑ Schools (Public School) ❑ Relocatable Public School Bldg. 13 Conditioned Spaces ❑ Unconditioned Spaces 2x4 @ 16 ❑ Skylight Area for Large Enclosed Space > 5000 ftz (If checked include the NRCC-ENV-04-E with submittal) B. ENVELOPE DETAILS — Framed 1 2 3 4 5 6 7 8 9 10 11 Tag/ID Assembly Type Frame Material Frame Depth Frame Spacing Appendix JA4 Reference Cavity R -value Continuous Insulation R -value Proposed U -Factor Required U -Factor From Tables, B, C, D Comments 1 Wall Wood 2x4 @ 16 4.3.1-D22 15 0.0 0.059 0.059 R-13 Wall 2 Roof Wood 2x4 @ 24 4.2.1-A20 30 0.0 0.031 0.039 R-30 Roof Attic C. ENVELOPE DETAILS — Non -framed 1 2 3 4 5 6 7 8 9 10 Tag/ID Assembly Type Assembly Materials Thickness (inches) Interior or Core Insulation R -value Continuous Insulation R -value Appendix JA4 Reference Proposed U -Factor Required U -Factor from Tables, B, C, D Comments Required U -Factor from Tables, B, C, D Comments D. ENVELOPE DETAILS — Mass 1 2 3 4 5 6 7 8 9 10 11 Tag/ID Mass Type Density (Ib/ft3) Mass Thickness (inches) Furring Strip Thickness (inches) Interior Insulation R -value Exterior Insulation R -value Appendix JA4 Reference Proposed Insulation U -factor Required U -Factor from Tables, B, C, D Comments CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA ENVELOPE COMPONENT APPROACH r��) CEC-NRCC-ENV-01-E (Revised 06/14) UAW-UKNIA ENEHUY GUMMIJJIUN CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E Envelope Component Approach (Page 2 of 4) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 E. ROOFING PRODUCTS (COOL ROOF) 1 2 3 4 5 6 7 8 9 10 11 Mass Roof Whole Building Air Leakage Testing Comments Proposed Minimum Required Aged Solar Thermal SRI Aged Solar Thermal SRI 25 Ib ft2 CRRC Product or greater Roof Pitch ID Number Product Type Reflectance Emittance (Optional) Reflectance Emittance (optional) Comments ❑ 5/12 ❑1 0.20 0.75 0.20 0.75 R-30 Roof Attic ❑ ❑1 ❑ ❑' ❑ An aged solar reflectance less than 0.63 is allowed provided the maximum roof / ceiling LI -factor in TABLE 140.3 is not exceeded ❑ High-rise residential buildings and Hotels and Motels with low -sloped roofs in Climate Zones 1 through 8, 12 and 16 are exempted from aged Solar Reflectance and emittance requirements. ❑ High-rise residential buildings and Hotels and Motels with steep -sloped roofs in Climate Zones 1 and 16 are exempt from aged Solar Reflectance and emittance requirements. ❑ The roof area covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from aged Solar Reflectance and emittance requirements To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in §110.8(i)4. Select the applicable coating: ❑ Aluminum -Pigmented Asphalt Roof Coating ❑ Cement -Based Roof Coating ❑ Other NOTES: 1. Check the box if the aged Solar reflectance was not available in the Cool Roof Rating Council's Rated Product Directory, Then use the equation in Section 110.8(i)2 where the Initial Reflectance value from the some directory and use the equation (0.2+B(p;,i;rio1 — 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance and a is either set to 0. 65for Field -Applied Coatings or it is set to 0. 70for all other roofing products other than Field -Applied Coating. 2. Calculate the SRI Value by using the SRI -Worksheet at (TBD) and enter the resulting value in the SRI Column above and attach a copy for the SRI -Worksheet NRCC-ENV-03-E to the to this form. F. Air Barrier 1 2 3 4 5 Tag/ID Air Barrier Material Type Air Barrier Assembly Type Whole Building Air Leakage Testing Comments CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 pp - STATE OF CALIFORNIA ENVELOPE COMPONENT APPROACH rn-J4 CEC-NRCC-ENV-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E Envelope Component Approach (Page 3 of 4) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 G. FENESTRATION PROPOSED AREAS AND EFFICIENCIES 1 2 3 4 5 6 7 8 9 10 11 12 Tag/ID Fenestration Type Area Orientation N, S, W, E or Roof # of Panes Max U -Factor Overhang Max (R)SHGC Min VT Label Conditions Status Comments H. ENVELOPE MANDATORY MEASURES Indicate location on building plans of Mandatory Envelope Measures Note Block: ENV -MM INSTRUCTIONS TO APPLICANT ENVELOPE COMPLIANCE & WORKSHEETS (check box if worksheet are included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Compliance Manual. 0 NRCC-ENV-01-E Certificate of Compliance. Required on plans for all submittals. ❑ NRCC-ENV-04-E Use when minimum skylight requirements for large enclosed spaces are required in climate zones 2 through 15. Optional on plans. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA ENVELOPE COMPONENT APPROACH CEC-NRCC-ENV-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E Envelope Component Approach (Page 4 of 4) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. in Documentation Author Name: Nicholas L Blgnardl NR08-12-3847 Documentation Author Signature: Company FRI Energy Consultants, LLC Signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/state/zip: Campbell, CA 95008 Phone: 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone` 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA FENESTRATION WORKSHEET CEC-NRCC-ENV-02-E (Revised 06/14) CALIFC ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ENV-02-E Fenestration Worksheet (Page 1 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 A. WINDOWS DETAILS Worksheet §140.3(a)5B and C NOTE: Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 116-A and Table 1168. Site -built fenestration less than 1,000 ft2, or more than or equal to 1, 000 ft2 see Reference Nonresidential Appendix NA6. 1 2 3 4 5 1 6 1 7 8 1 9 10 1 11 1 12 13 14 Tag/I D Window Type (e.g., Window -1 Area Fenestration D. Enter Proposed West Window Area 10 ft2 Proposed West Window Area Note: If the PROPOSED WEST WINDOW AREA is greater than the MAXIMUM STANDARD WEST AREA then the envelope component approach may not be used. Overhang U -Factor SHGC VT Dimensions F. Linear Display Perimeter 0 Calculated C o — a Q a o — a Q C o — a Q H V HIV (R)SHGC Proposed Max (R)SHGC Allowed B. WEST WINDOW AREA CALCULATION See §140.3(a)5A in the Energy Standards A. Gross West Exterior Wall Area 81 ft2 x 0.40 = 33 ft2 40% of Gross West Facing Exterior Wall Area; or B. West Display Linear Perimeter 0 FT x 6 ft = 0 ft2 West Display Perimeter Area C. Enter Larger of A or B 33 ft2 Maximum Standard West Area D. Enter Proposed West Window Area 10 ft2 Proposed West Window Area Note: If the PROPOSED WEST WINDOW AREA is greater than the MAXIMUM STANDARD WEST AREA then the envelope component approach may not be used. C. WINDOW AREA CALCULATION for all other orientations other than West - See §140.3(a)5A in the Energy Standards E. Gross Exterior Wall Area 164 ft2 x 0.40 = 66 ft' 40% of Gross Exterior Wall Area or F. Linear Display Perimeter 0 FT x 6 ft = 0 ft2 Display Perimeter Area G. Enter The Larger of E or F 66 ft2 Maximum Standard Area H. Enter Proposed Window Area 0 ft2 Proposed Window Area Note: If the PROPOSED WINDOW AREA is greater than the MAXIMUM STANDARD AREA then the envelope component approach may D. SKYLIGHT AREA CALCULATION See §143(a)6A in the Energy Standards ACTUAL GROSS ROOF AREA STANDARD ALLOWED A IF Atrium/Skylight Height is <_ 55 ft; or 105 ft2 X 0.05 = 5 ft2 B. IF Atrium/Skylight Height is > 55 ft ft2 X 0.10 = ft2 C. Proposed Skylight Area (from plans) 0 ft2 D. Skylight SSR %' 2 = Proposed Skylight Area Divided by Actual Gross 0.0 1. If the SKYLIGHT SSR % is less than or equal to 5% then choose the appropriate column in Table 140.3-B and C and row in Table 140.3-D. 2. If the SKYLIGHT SSR % is greater than 5% then the Envelope Component Approach may not be used. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA FENESTRATION WORKSHEET CEC-NRCC-ENV-02-E (Revised 06/14) CALIFCjt_® I ENERGY COMMISSION _ CERTIFICATE OF COMPLIANCE NRCC-ENV-02-E Fenestration Worksheet (Page 3 of 3) Project Name: Cupertino Dental Group °ate Prepare°: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Nicholas L Blgnardl NR08-12-3847 Documentation Author Signature: Company FRI Energy Consultants, LLC signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/state/zip: Campbell, CA 95008 Phone: 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/state/zip: San Jose, CA 95123 Phone: 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV -MM Project Name Date Cupertino Dental Group 4/15/2015 DESCRIPTION Building Envelope Measures: Installed insulating material shall have been certified by the manufacturer to comply with the California Quality §110.8(a): Standards for insulating material, Title 20 Chapter 4, Article 3. All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of §110.8(c): Sections 2602 and 707 of Title 24, Part 2. The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value §110.8(f): of no less than R-13 between framing members. All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, §110.7(a): weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.z of §110.6(a): window area, 0.3 cfm/ft.Z of door area for residential doors, 0.3 cfm/ft.Z of door area for nonresidential single doors (swinging and sliding), and 1.0 cfm/ft.z for nonresidential double doors (swinging). §110.6(a): Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -factor. Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the §110.6(a) : applicable default SHGC. Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be §110.6(b): weatherstripped (except for unframed glass doors and fire doors). Ener Pro 6.5 by Ener Soft User Number: 1315 RunCode: 2015-04-15721:40:54 ID: 0150290 Page 9 of 30 STATE OF CALIFORNIA INDOOR LIGHTING r�,r CEC-NRCC-LTI-01-E Revised 06/14 UALIFUKNIA tNtKUY UUMMIbbIUN CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 1 of 5) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 Climate Zone: 4 Conditioned Floor Area : 105 YES NO FORM TITLE YES NRCC-LIT-01-E Certificate of Compliance. All Pages required on plans for all submittals. Unconditioned Floor Area : 0 Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. General Information Indoor Lighting Power Allowance NO NRCC-LIT-04-E j Tailored Method Worksheets NQ NRCC-LIT-05 E Line Voltage Track Lighting Worksheets Building Type: ❑ Schools El Nonresidential ❑ Relocatable Public Schools ❑ ❑ High -Rise Residential Conditioned Spaces ❑ ❑ Hotel/Motel Unconditioned Spaces Phase of Construction: ❑ New Construction ❑ Addition ❑ Alteration Method of Compliance: ❑ Complete Building ❑ Area Category ❑ Tailored LIGHTING COMPLIANCE DOCUMENTS (select yes for each document included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission. YES NO FORM TITLE YES NRCC-LIT-01-E Certificate of Compliance. All Pages required on plans for all submittals. YES NRCC-LIT-02-E Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. YES NRCC-LIT-03-E Indoor Lighting Power Allowance NO NRCC-LIT-04-E j Tailored Method Worksheets NQ NRCC-LIT-05 E Line Voltage Track Lighting Worksheets Summary of Allowed Lighting Power Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces Watts I Watts Installed Lighting 96 1. NRCC-LTI-01-E, page 4 + PORTABLE ONLY FOR OFFICES 2. NRCC-LTI-01-E, page 3 + Minus Lighting Control Credits 3' 0 NRCC-LTI-02-E, page 2 4 Adjusted Installed Lighting Power _ 96 (row 1 plus row 2 minus row 3) CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance Installed Lighting NRCC-LTI-01-E, page 4 1 + 0 Minus Lighting Control Credits 0 _ NRCC-LTI-02-E, page 2 Adjusted Installed Lighting Power (row 1 minus row 3) 0 June 2014 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/ CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 2 of 5) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 5. Complies ONLY if Installed <_ Allowed Complies ONLY if Installed <_ Allowed NO Form/Title Allowed Lighting Power Allowed Lighting Power NRCI-LTI-01-E - Must be submitted for all buildings 6. Conditioned NRCC-LTI-03-E, page 1 105 Unconditioned NRCC-LTI-03-E, page 1 0 Declaration of Required Installation Certificates — Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. NRCI-LTI-01-E - Must be submitted for all buildings ❑ Field Inspector NRCA-LTI-03-A - Must be submitted for automatic daylight controls. NRCI-LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), ❑ Field Inspector NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls. to be recognized for compliance. •/ NRCI-LTI-03-E - Must be submitted for a line -voltage track lighting integral current limiter, or for a supplementary ❑ Field Inspector overcurrent protection panel used to energize only line -voltage track lighting, to be recognized for compliance. NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a ❑ Field Inspector conference room, a multipurpose room, or a theater to be recognized for compliance. NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. ❑ Field Inspector NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for ❑ Field Inspector compliance. Declaration of Required Certificates of Acceptance — Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. ❑ Field Inspector NRCA-LTI-03-A - Must be submitted for automatic daylight controls. ❑ Field Inspector NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls. ❑ Field Inspector 71 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING 'EC -NRCC-LTI-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION "°°mv011` CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 3 of 5) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: ® CONDITIONED SPACE ❑ UNCONDITIONED SPACE A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST ❑ The actual indoor lighting power listed on this page and on the next page includes all installed permanent and planned portable lighting systems. ❑ When Complete Building Method is used for compliance, list each different type of luminaire on separate lines. ❑ When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines ❑ Also include track lighting in schedule, and submit the track lighting compliance form (NRCC-LTI-05-E) when line -voltage track lighting is installed. B. Installed Portable Luminaires in Offices — Exception to Section 140.6(a) ❑ This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of this compliance form. ❑ This section is used to determine if greater than 0.3 watts of portable lighting is planned for any office ❑ Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allowance shall not be traded between offices having different lighting systems. Office Portable Luminaire Office Installed Portable Luminaire Watts Per Square Office Location Field Schedule Foot Inspector A B C D E F G H I J Installed Z c portable 0 L 0 Watts If F <_ 0.3, Identify Office area in which 35. 3 0- luminaire � v '^ � per enter zero; E x G these portable luminaires are T, v Complete Luminaire Description L". watts in this 0 rD square installed (i.e., LED, under cabinet, furniture mounted Watts per ° office K : STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-1-TI-01-E (Revised 06/14) UALIF-UHNIA LNLHUY UUMMIJJIUN " CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 4 of 5) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: IZI CONDITIONED SPACE ❑ UNCONDITIONED SPACE C. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Luminaire Schedule Installed Watts Location Field Inspector 1 A B C D E F G H How wattage was determined d o o ro Complete Luminaire Description 30 ^° 3 z s E E (i.e, 3 lamp fluorescent troffer, 3 O Z d w a o dQ °' a x Primary Function area in which z — F32T8, one dimmable electronic ballast) `� - 00 ; —' (D rD M� C- ° these luminaires are installed Pass Fail 2 Lamp 4 ft T8 48.0 ® ❑ 2 96 Office <= 250 sqft ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ INSTALLED WATTS PAGE TOTAL: 96 Enter sum total of all pages into NRCC-LTI-01-E; Page 2 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 5 of 5) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. of Documentation Author Name: Nicholas L Blgnardl NR08-12-3847 Documentation Author Signature:: Company FRI Energy Consultants, LLC Signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/State/Zip: Campbell, CA 95008 phone: 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone: 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING — LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 06/14) L;ALIFUKNIA LNLKIiY GUMMItNUN CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 1 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 The NRCC-LTI-02-E shall be used to document all mandatory and prescriptive lighting controls that are applicable to the project. Mandatory Lighting Control Declaration Statements (Indicate if the measure applies by checking yes or no below.) YES NO Control Requirements JLighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with Section 110.9. J Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with Section 130.4(b). JOne or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and §130.0. Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4(b). A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.0. Additionally, an Installation Certificate shall be installed in accordance with Section 130.4(b). J All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with Section 130.1. All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.1(a)4. •/ The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the multi-level lighting control requirements in accordance with Section 130.1(b). J All installed indoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements in Section 130.1(c). JLighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. JLighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in accordance with Section 130.1(e). Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for Jnormal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with Section 130.4.(a). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut -OFF controls, and demand responsive controls. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING — LIGHTING CONTROLS Ai CEC-NRCC-LTI-02-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION ''wMw" CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 2 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: 0 CONDITIONED SPACES ❑ UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST PAF Credit Calculation Z n (D N D _D !D a 1 o r 's (D n N rD fD Standards Complying With ° v, v to x r. �• Lighting Control Schedule (✓ all that apply, or enter 'E' if Exempted) C- o n v o (D o A B C D E F G H I J K L M N O Type/ Description of Lighting Control (i.e.: occupancy sensor, # N N t4;' `4' F- A i4; Location in Building automatic time switch, of o 0 0 0 cu 0 P o v _ dimmer, automatic daylight, Units N Z' o m �..� �... N .� etc... ) DIMMER ❑ ❑ ❑ ❑ ❑ ❑ Control Credit PAGE TOTAL (Sum of Column M): 0 IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF Control Credit for all pages HERE (Sum of all Column M): 0 Enter Control Credit total into NRCC-LTI-01-E; Page 1. 1. §130.1(a) =Manual area controls; §130.0(b) = Multi Level; §130.1(c) =Auto Shut -Off; §130.1(d) =Mandatory Daylight; §130.1(e) =Demand Responsive, §140.6(d) = Additional lighting controls installed to earn a PAF, • §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6-A for correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also required to be filled out signed, and submitted. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING — LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 06/14) l HLIr VRIVIH GIVCRV T l VNIIVIIJJIVIV CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 3 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Nicholas L Bignardi NR08-12-3847 Documentation Author Signature: Company: FRI Energy Consultants, LLC signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/State/Zip: Campbell, CA 95008 Phone` 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone: 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE :EC-NRCC-LTI-03-E (Revised 06/14) GALIFURNIA ENEHUY UUMMI55IUN CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 1 of 4) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 ALLOWED LIGHTING POWER A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: 0 CONDITIONED spaces ❑ UNCONDITIONED spaces A. SUMMARY TOTALS OF LIGHTING POWER ALLOWANCES ❑ If using Complete Building Method for compliance, use only the total in column (a) as total allowed building watts. ❑ If using Area Category Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b) as the total allowed building watts (a) (b) 1. Complete Building Method Allowed Watts. Documented in section B of NRCC-LTI-03-E (below on this page) 2. Area Category Method Allowed Watts. Documented in section C-1 of NRCC-LTI-03-E (below on this page) 105 3. Tailored Method Allowed Watts. Documented in section A of NRCC-LTI-04-E 0 TOTAL ALLOWED BUILDING WATTS. Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 105 I❑ Check here if building contains both conditioned and unconditioned areas. B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE A B 105 C 0 D TYPE OF BUILDING (From §140.6 Table 140.6-B) WATTS PER (ft) X COMPLETE BLDG. AREA = ALLOWED WATTS Total Area: Total Watts. Enter Total Watts into section A, row 1 (Above on this page) C -1 AREA CATEGORY METHOD TOTAL LIGHTING POWER ALLOWANCES (C-2 plus C-3) Watts Total from section C-2 105 Total from section C-3 0 Total Watts. Enter Total Watts into section A, row 2 (Above on this page) 105 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE 'EC -03 (Revised 06/14) UAW-UKNIA ENERGY UUMMISSIUN CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 2 of 4) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: m CONDITIONED spaces ❑ UNCONDITIONED spaces C -2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE ❑ Do not include portable lighting for offices. Portable lighting for offices shall be documented only in section B of NRCC-LTI-01-E. ❑ Separately list lighting for each primary function area as defined in §100.1 of the Standards. A B C D AREA CATEGORY (From §140.6 Table 140.6-C) WATTS ALLOWED Location in Building Primary Function Area per Table 140.6-C PER (ft) X AREA (ft2) = WATTS Cupertino Dental Group Office <= 250 sqft 1.00 105 105 TOTALS 1 105 Enter sum total Area Category allowed watts into section C-1 of NRCC-LTI-03-E (this compliance form) 105 WATTS CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE RAN CEC-NRCC-LTI-03-E (Revised 06/14) GALIrUKNIA ENEHUY GUMMIJJIUN CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 4 of 4) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Nicholas L Bignardi NR08-12-3847 Documentation Author signature: Company: FRI Energy Consultants, LLC Signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/HERS Certification Identification (if applicable): City/state/zip: Campbell, CA 95008 Phone` 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone: 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA MECHANICAL SYSTEMS u :l% CEC-NRCC-MCH-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-01-E Mechanical Systems (Page 1 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 MECHANICAL COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. YES NO Form/Worksheet # Title El ❑ NRCC-MCH-01-E (Part 1 of 3) Certificate of Compliance, Declaration. Required on plans for all submittals. El ❑ NRCC-MCH-01-E (Part 2 of 3) Certificate of Compliance, Required Acceptance Tests (MCH -02A to 11A). Required on plans for all submittals. ❑ ❑ NRCC-MCH-01-E (Part 3 of 3) Certificate of Compliance, Required Acceptance Tests (MCH -12A to 18A). Required on plans where applicable. ® ❑ NRCC-MCH-02-E (Part 1 of 2) Mechanical Dry Equipment Summary is required for all submittals with Central Air Systems. It is optional on plans. 21 ❑ NRCC-MCH-02-E (Part 2 of 2) Mechanical Wet Equipment Summary is required for all submittals with chilled water, hot water or condenser water systems. It is optional on plans. El ❑ NRCC-MCH-03-E Mechanical Ventilation and Reheat is required for all submittals with multiple zone heating and cooling systems. It is optional on plans. MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms) Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems. The designer is required to check the applicable boxes for all acceptance tests that apply and list all equipment that requires an acceptance test. All equipment of the some type that requires a test, list the equipment description and the number of systems. Installing Contractor: The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified entity run the test for them. If more than one person has responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which they are responsible. Enforcement Agency: Plancheck — The NRCC-MCH-01-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. Inspector - Before occupancy permit is granted all newly installed process systems must be tested to ensure proper operations. Test Description MCH -02A MCH -03A MCH -04A MCH -05A MCH -06A MCH -07A MCH -08A MCH -09A MCH -10A MCH -11A Equipment # of Outdoor Single Zone Air Economizer Demand Supply Fan Valve Leakage Supply Water Hydronic Automatic Requiring Testing units Air Unitary Distribution Controls Control VAV Test Temp. Reset System Demand Shed or Verification Ducts Ventilation Variable Flow Control (DCV) Control ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA MECHANICAL SYSTEMS CEC-NRCC-MCH-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION ^""wR, CERTIFICATE OF COMPLIANCE NRCC-MCH-01-E Mechanical Systems (Page 2 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms) Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems. The designer is required to check the applicable boxes for all acceptance tests that apply and list all equipment that requires an acceptance test. All equipment of the some type that requires a test, list the equipment description and the number of systems. Installing Contractor: The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified entity run the test for them. If more than one person has responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which they are responsible. The following tests require a Enforcement Agency: Plancheck — The NRCC-MCH-01-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. Inspector - Before occupancy permit is granted all newly installed process systems must be tested to ensure proper operations. Test Description MCH -12A MCH -13A MCH -14A MCH -15A MCH -16A MCH -17A MCH -18A Equipment # of Fault Detection & Automatic Fault Distributed Energy Thermal Energy Supply Air Condenser Water ECMS Requiring Testing units Diagnostics for DX Detection & Storage DX AC Storage (TES) Temperature Reset Reset Controls or Verification Units Diagnostics for Air & Systems Systems Controls Zone ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA MECHANICAL SYSTEMS CEC-NRCC-MCH-01-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION �" CERTIFICATE OF COMPLIANCE NRCC-MCH-01-E Mechanical Systems (Page 3 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: NIChOIaS L Blgnardl NR08-12-3847 Documentation Author Signature: ,c `, .. Company FRI Energy Consultants, LLC Signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/State/zip: Campbell, CA 95008 Phone: 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone: 408-281-4400 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA HVAC SYSTEM REQUIREMENTS :;EG-NRGG-MGH-024E (RewSetl 06/14) CALIFORNIA ENERGY COMMISSION -- CERTIFICATE OF COMPLIANCE NRCC-MCH-02-E HVAC Dry System Requirements (Page 1 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 Equipment Tags and System Description' System 1 MANDATORY MEASURES Heating Equipment Efficiency3 Cooling Equipment Efficiency3 HVAC or Heat Pump Thermostats Furnace Standby Loss Control Low leakage AHUs Ventilation Demand Control Ventilations Occupant Sensor Ventilation Control6 Shutoff and Reset Controls' Outdoor Air and Exhaust Damper Control Isolation Zones Automatic Demand Shed Controls Economizer FDD Duct Insulation PRESCRIPTIVE MEASURES T-24 Sections Reference to the Requirements in the Contract DocumentS2 110.1 or 110.2(a) Page 6 110.1 or 110.2(a) Page 6 110.2(b), 110.2(c) Page 6 110.2(d) Page 6 110.2(f) Page 6 120.1(b) Page 6 120.1(c)4 Page 6 120.1(c)5, 120.2(e)3 Page 6 120.2(e) Page 6 120.2(f) Page 6 120.2(g) Page 6 120.2(h) Page 6 120.2(i) Page 6 120.4 Page 6 Equipment is sized in conformance with 140.4(a & b) y 140.4(a&b) Supply Fan Pressure Control 140.4(c) Page 6 Simultaneous Heat/Cool8 140.4(d) Page 6 Economizer 140.4(e) Page 6 Heat and Cool Air Supply Reset 140.4(f) Page 6 Electric Resistance Heating9 140.4(g) Page 6 Duct Leakage Sealing and Testing.'D 140.4(1) Page 6 Notes: 1. Provide equipment tags (e.g. AHU 1 to 10) and system description (e.g. Single Duct VAV reheat) as appropriate. Multiple units with common requirements can be grouped together. 2. Provide references to plans (i.e. Drawing Sheet Numbers) and/or specifications (including Section name/number and relevant paragraphs) where each requirement is specified. Enter "N/A" if the requirement is not applicable to this system. 3. The referenced plans and specifications must include all of the following information: equipment tag, equipment nominal capacity, Title 24 minimum efficiency requirements, and actual rated equipment efficiencies. Where multiple efficiency requirements are applicable (e.g. full- and part -load) include all. Where appliance standards apply (110.1), identify where equipment is required to be listed per Title 201601 et seq. 4. Identify where the ventilation requirements are documented for each central HVAC system. Include references to both central unit schedules and sequences of operation. If one or more space is naturally ventilated identify where this is documented in the plans and specifications. Multiple zone central air systems must also provide a MCH -03-E form. 5. If one or more space has demand controlled ventilation identify where it is specified including the sensor specifications and the sequence of operation. 6. If one or more space has occupant sensor ventilation control identify where it is specified including the sensor specifications and the sequence of operation 7. If the system is DDC identify the sequences for the system start/stop, optimal start setback (if required) and setup (if required). For all systems identify the specification for the thermostats and time clocks (if applicable). 8. Identify where the heating, cooling and deadbond airflows are scheduled for this system. Include a reference to the specification of the zone controls. Provide a MCH -03-E form. 9. Enter N/A if there is no electric heating. If the system has electric heating indicate which exception to 140.4(g) applies. 10. If duct leakage sealing and testing is required, a MCH -04-A form must be submitted. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA HVAC SYSTEM REQUIREMENTS CEC-NRCC-MCH-02-E (Revised 06113) CALIFORNIA ENERGY COMMISSION - CERTIFICATE OF COMPLIANCE NRCC-MCH-02-E HVAC Wet System Requirements (Page 3 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Nicholas L Blgnard'I NR08-12-3847 Documentation Author Signature: Company FRI Energy Consultants, LLC signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/State/Zip: Campbell, CA 95008 Phone` 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone: 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA MECHANICAL VENTILATION AND REHEAT CEC-NRCC-MCH-03-E (Revised 06/14) GALIFUHNIA tNLF(GY GUMMISSIUN CERTIFICATE OF COMPLIANCE NRCC-MCH-03-E Mechanical Ventilation & Reheat (Page 1 of 2) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 ACTUAL DESIGN INFO (FROM EQUIPMENT SCHEDULES, ETC) AREA BASIS OCCUPANCY BASIS MINIMUM VAV Reheated Primary Air CFM VAV Deadband Primary Air CFM A B C D E F G H I 1 K L M N 0 P Q R S T N D O < m vi x ,<„ D L1 O O rn Gl T Gl D z D D o z o vm, O O O v D z Z 3 O D << m o D v, Ll T G1 D _a v T D n \ Z .._. 0 On D z r r Z O �' "'r{ z n O Z �' p O D p 2 m O 3 r 3 D D 3 Z 3 D z D Z 3 v O m T 3 v z m s W Z 3 T D �< O r� C y m x D -nrO T O 3— O < O Z z _"" n O r rn A Z o 3 O ao D T Z O D< 300 0 n w O o R Z> O T D 3 x _ p C O x p O m 2 n O — J N Z O O\ T Z p o (") D Z d w D ru T p p n Z v 0 Z O n O m to Cuperi 105 0.15 16 1.1 15.0 16 16 Y Total 16 Yellow shaded cells require user input. Remaining cells are protected and automatic B. The largest amount of primary air supplied by the terminal unit when it's operating in the cooling mode. C. The smallest amount of primary air supplied by the terminal unit in the deadband mode. D. The largest amount of primary air supplied by the terminal unit when it's operating in the heating mode. E. A terminal unit can be controlled with DDC controls, or non -DDC controls. Each control category has different reheat limitations in code. F. Transfer Air must be provided where Required Ventilation Airflow (Column M) is greater than the Design Primary Deadband Airflow (Column C). H. Minimum ventilation rate per Section §120.1. Table 120.1-A. J. Based on number of fixed seats where applicable or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. M. Required Ventilation Airflow (Req'd Ventilation Airflow) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS (Column I or L) N. This column identifies whether or not the Design Primary Deadband Airflow complies or not. It compares the value in column M to the value in column C and column F. O. Design Primary Cooling Airflow * 0.50 for DDC, Design Primary Cooling Airflow * 0.30 for Non -DDC. If the Design Primary Cooling Airflow is less than 300 cfm, then this is not applicable. P. Maximum of Column M and Column 0. If the Design Primary Cooling Airflow is 300 cfm or less, then this is not applicable. Q. This column identifies whether or not the Design Primary Reheat Airflow at the zone level, complies or not. It compares the value in column P to the value in column D. R. Design Primary Cooling Airflow * 0.20 for DDC. Not applicable for Non -DDC zones or zones where Design.Primary Cooling Airflow is is 300 cfm or less. S. Maximum of Column M and Column R. Not applicable if the Design Primary Cooling Airflow is 300 cfm or less. T. This column identifies whether or not the Design Primary Deadband Airflow at the zone level, complies or not. It compares the value in column S to the value in column C. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA MECHANICAL VENTILATION AND REHEAT CEC-NRCC-MCH-03-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION - CERTIFICATE OF COMPLIANCE NRCC-MCH-03-E Mechanical Ventilation & Reheat (Page 2 of 2) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: NIChOIaS L BlgnarCll NROB-1 Z-384% Documentation Author signature:' _y Company: FRI Energy Consultants, LLC signacureDate: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/state/zip: Campbell, CA 95008 Phone: 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone. 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA REQUIRED ACCEPTANCE TESTS F-11), (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-04-E Required Acceptance Tests (Page 1 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 MECHANICAL COMPLIANCE FORMS & WORKSHEETS (indicate if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. Forms NRCC-MCH-04-E and NRCC-MECH-05-E are alternative forms to NRCC-MCH-01-E, NRCC-MCH-02-E and NRCC- MCH-03-E for projects using only single zone packaged HVAC systems. YES NO Form Title NRCC-MCH-04-E (1 of 2) Certificate of Compliance. Required on plans when used. NRCC-MCH-04-E (2 of 2) Mechanical Acceptance Tests. Required on plans when used. NRCC-MCH-05-E (1 of 2) HVAC Prescriptive Requirements. It is required on plans when used. NRCC-MCH-05-E (2 of 2) Mechanical SWH Equipment Summary is required for all submittals with service water heating, pools or spas. It is required on plans where applicable. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA REQUIRED ACCEPTANCE TESTS rrl� CEC-NRCC-MCH-04-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-04-E Required Acceptance Tests (Page 2 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the applicable boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems. The NA number designates the Section in the Appendix of the Nonresidential Reference Appendices Manual that describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Enforcement Agency: Systems Acceptance. Before occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. Systems Acceptance. Before occupancy permit is granted. All newly installed HVAC equipment must be tested using the Acceptance Requirements.. The NRCC-MCH-04-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. The equipment requiring testing, person performing the test (Example: HVAC installer, TAB contractor, controls contractor, PE in charge of project) and what Acceptance test must be conducted. The following checked -off forms are required for ALL newly installed and replaced equipment. In addition a Certificate of Acceptance forms shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. The building inspector must receive the properly filled out and signed forms before the building can receive final occupancy. Test Description MCH -02-A MCH -03-A MCH -04-A MCH -05-A MCH -06-A MCH -07-A MCH -11-A MCH -12-A MCH -14-A MCH -18-A Test Performed By: Equipment # of Outdoor Single Zone Air Economizer Demand Supply Automatic FDD for Distribute Energy Requiring units Air Unitary Distribution Controls Control Fan VAV Demand Packaged d Energy Managem Testing or Ducts Ventilation Shed DX Units Storage ent Verification (DCV) Control DX AC Control Systems System CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA REQUIRED ACCEPTANCE TESTS R 11 CEC-NRCC-MCH-04-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-04-E Required Acceptance Tests (Page 3 of 3) Project Name: Cupertino Dental Group Date Prepared: 4/15/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Nicholas L Blgnardl NR08-12-3847 Documentation Author Signature: Company: FRI Energy Consultants, LLC Signature Date: 4/15/2015 Address: 21 N. Harrison Ave, Suite 210 CEA/ HERS Certification Identification (if applicable): City/State/Zip: Campbell, CA 95008 Phone_ 408-866-1620 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Paul Fick Responsible Designer Signature: Company: Paul H. Fick Architect Date Signed: Address: 550 Calero Ave License: City/State/Zip: San Jose, CA 95123 Phone` 408-281-4400 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014