B-2017-0058 CITY OF CUPERTINO BUILDING PE ' T
BUILDING ADDRESS: CONTRACTOR: P RMIT NO:B-2017-0058
10340 BYRNE AVE CUPERTINO,CA 95014-2814(357 15 075) WILLOW GLEN
ELECTRIC INC
SAN JOSE,CA 95155
OWNER'S NAME: LANGBERG MICHAEL DAVID AND GORDON DEBRA ELL D•TE ISSUED:01/10/2017
OWNER'S PHONE:408-366-0845 P;ONE NO:(408)289-9725
LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT I 0:
License Class C-10 Lic.#591918
Contractor WILLOW GLEN ELECTRIC INC Date 04/30/2018 XBLDG —ELECT — 'LUMB
I hereby affirm that I am licensed under the provisions of Chapter 9(commencing —MECH X RESIDENT =COMMERCIAL
with Section 7000)of Division 3 of the Business&Professions Code and that my
license is in full force and effect. JOB DESCRIPTION:
(N)EV CHARGING STA ION(40 AMP)GARAGE
I hereby affirm under penalty of perjury one of the following two declarations:
t I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued.
bm I have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. Sq.Ft Floor Area: V.luation:$990.00
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct.I agree to comply with all city and county ordinances APN Number: 0.cupancy Type:
and state laws relating to building construction,and hereby authorize 35715 075
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We)agree to save indemnify and keep harmless the
City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXP S IF WORK IS NOT STARTED
may accrue against said City in consequence of the granting of this permit. WITHIN 180 D' S OF PERMIT ISSUANCE OR
Additionally,the applicant understands and will comply with all non-point
source regulations per the Cupertino Municipal Code,Section 9.18. 180 DAYS FRO LAST CALLED INSPECTION.
,Signaturz i J Date 01/10/2017 Issued by:Kim Dunbar
vv �� Date:01/10/2017
OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS;
following two reasons: All roofs shall be inspected.rior to any roofing material being installed.If a roof is
1. I,as owner of the property,or my employees with wages as their sole installed without first obta'.'.g an inspection,I agree to remove all new materials for
compensation,will do the work,and the structure is not intended or offered for inspection.
sale(Sec.7044,Business&Professions Code)
2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant:
contractors to construct the project(Sec.7044,Business&Professions Code). Date:01/10/2017
I hereby affirm under penalty of perjury one of the following three declarations:
ALL ROOF CO RINGS TO BE CLASS"A"OR BETTER
1. I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. HAZARD n US MATERIALS DISCLOSURE
2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the
Section 3700 of the Labor Code,for the performance of the work for which this California Health 8z Safe Code,Sections 25505,25533,and 25534. I will
permit is issued. maintain compliance with t a e Cupertino Municipal Code,Chapter 9.12 and the
3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Se tion 25532(a)should I store or handle hazardous
shall not employ any person in any manner so as to become subject to the material. Additionally,sho Id I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
Worker's Compensation laws of California. If,after making this certificate of will maintain compliance wi h the Cupertino Municipal Code,Chapter 9.12 and
exemption,I become subject to the Worker's Compensation provisions of the the Health&Safe Code,Sections 25505,25533,and 25534.
Labor Code,I must forthwith comply with such provisions or this permit shall
be deemed revoked. C /
Owner or authorized aged: .�
APPLICANT CERTIFICATION Date:01/10/2017
I certify that I have read this application and state that the above information is CONS UCTION LENDING AGENCY
correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is°construction lending agency for the performance
relating to building construction,and hereby authorize representatives of this city of work's for which this per it is issued(Sec.3097,Civ C.)
to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments,costs,and expenses which may accrue against said City in Lender's Address
consequence of the granting of this permit. Additionally,the applicant understands
and will comply with all non-point source regulations per the Cupertino Municipal ARC TECT'S DECLARATION
Code,Section 9.18. I understand my plans shall be used as public records.
Licensed
Signature Date 01/10/2017
Professional
(De thr/v6eK-6
\.1
ALTERNATIVE ENERGY PERMIT APPLIC PION
I COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISIOAE
1,I?rr 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255
llPER"!• Intl (408)777-3228• FAX(408)777-3333•buii� 'Is t, aaa;.il'c,,c,t'
CPROJECT ADDRESSII0 3` :0 r/i ,5469-1(444.... APN# 35 5—.m 0
45
�F j�
OWNER NAME is �J $� PHONE 3 � � V� MAIL°' ` �� �
J jam• 3 rite �/J c
STREET ADDRESS /p .f�y a°a V CITY STATE,-ZIP ,. ,a -`"0/`,.,✓ FAX
41-
CONTACT NAME Mark Londre PHONE (408)289.9725 -MAIL
""ffice@willowglenelectric.com
STREET ADDRESS P.
O. Box 8430 CITY,STATE,ZIP San Jose, CA 9.155 FAX(408)289-9725
❑OWNER 0 OWNER-BUILDER 0 OWNER AGENT CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITEC 0 ENGINEER 0 DEVELOPER 0 TENANT
CONTRACTOR NAME Mark Londre LICENSE NUMBER 591918 LICENSE 'E ^-10 BUS.LIC# 15897
COMPANY NAME Willow Glen Electric, Inc. E-MAIL office@willowglenelec ric.com FAX (408)289-9725
STREET ADDRESS P. O. Box 8430 CITY,STATE,ZIP San Jose, CA 9',155 PHONE (408)289-9725
ARCHITECT/ENGINEEER NAME N/A LICENSE NUMBER BUS.LIC#
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
USE OF 4 SFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN
STRUCTURE: 0 Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE 0 Yes 0 No
❑SOLAR PANELS it ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 0 HER:
FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): T a;W;:''`,-
DESCRIPTION OF WORK /, o
Electric Vehicle .Charging Circuit:� (' ) -10 ee.et jCI-CC-Z-444
k.
W/AIA,'&14 4 f, ,A07/PLe -C t `te `.dt- .e i'_- -X.1.4.ki - 'a +�•�.
Le b/id :0 • -fr.
ir
ric; DB
.....)0, ,......)_
By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building conti n I tho'ze rep tatives of Cupertino to enter the above-identified property for inspection purposes.
Signature of Applicant/Agent: %'/(44 R �twi Date: i- f / -
SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY
W : R-THE-COIJNTER
❑.:EXPRESS=.
6
�
/j,
%-
.
rJ �
(/ 0 LARGE
ck
❑ MAJOR -
PVApp_2011.doc revised 03/16/11
uuci,5oiW_i Mnvewpe w: ytSVbSbI.S-bZ2525-4251 r-yyLt-Gt1 F5ZDC6289
SMOKE/ CARBON MONOXIDE ALARMS
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
90300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildina0cupertino.orct
Permit No,B-2017-0058
Address 10340 Byrne Avenue, Cupertino #of Alarms Smoke: 5 Carbon Monoxide: 1
PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE
HAS BEEN SI =NSD AND R ; T, URNED TO THE BUILDING DIVISION ,
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for
inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon
Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s)
X
X
On every level of a dwelling unit including basements
X
X
Within each sleeping room
X,
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s). may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal, of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section 8314 and CBC Sectionsi 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of ;the above -referenced property, I hereby certify that the alarms) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms have been tested and are operational, as of the date signed
below.
1 have read and agree to comply with the terms and conditions of this statement
Owner (or Owner Agent's) Name:
Dousignea by:
Mike Lan ber
si natur ...!!!u �... JAMAMA ...................Dat /27(20
Contractor Name:
WB796318F0451...
Sinature................................................................... Lic.#...................................... Date:...................
Smoke and CO form.doc revised 03118114
.7
DocuSign Envelope ID: 980635C3-6288-481 F-992E-CE1 F52DC6289
CUPERTINO
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 - building@cuoertino.orq
Owner Name, Mi ke Lan berg Permit No. B-2017-0058
Address 10340 Byrne Avenue, Cupertino, CA 95014
PERMIT CANNOT BE EINALED AND COMPLETED UNTIL THIS CERTIFICATE
HAS BEEN S +" AND FT 1 RNI D TO THE BUILDING DIVISION
Please refer to the attached California Civil Code Sections 1101.1 --1101.8 which are part of this Certification form.
1. Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature:DocuSigned by: Date: 1/27/2017
F-1No Go to Question 2.E6t3o1BaF0*451,w1
..
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Sign below and skip the rest of the form.
DocuSigned by:
Owner' Signature:��
❑ No Go to Question 3.
8A66796318F0451...
Date:1/27/2017
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature:Doeusignedby, Date: 1/27/2017
❑ No Go to Question 4.E631BFOi5l
...
4. Is your real property built and available for use or occupancy on or before January 1,1994?
❑ No My real property is built and available for use or occupancy after. January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
DocuSigned by:
Owner' Signature: NLL t0A*trj Date: 1/2 7/2017
❑ Yes My real property i san6 svoiiable for use or occupancy on or before January 1, 1994.
Civil Code Sections I 10 1. 1 through 1101.8 apply. Refer to the attached.
❑ My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing
fixtures to be replaced with water -conserving plumbing .fixtures throughout the building. On or before January 1,
2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless
of whether property undergoes alterations or improvements).
❑ My property is a inultifaniily residential real. property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
SB407 2015.doc revised 02104115
y DoceSig"`n Envelope ID: 980635C3-6288-481 F -992E -CEI F52DC6289
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced
prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through
1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation
requirements. and that the water-conservir&iftW yla fixtures comely with the requirements as indicated in the table below.
Owner's (or Owner Agent's) Signature] NUt: t, ("M _ - Date:-`/ ` ` / "' J- `
8F0451
Upon completing and signing this Certificate, please return it to the Building Division in order to ttnal your permit.
1. 1f the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, itis not require to upgra .
SB407 2015doc revised 02/04115
Non -Compliant
Water -Conserving Plumbing Fixture
Plumbing Fixture/
(Fixture Complying with Current Code Applicable to New Construction)
Maximum Water Usage/Flow Rate
Fixture Type
Water Usage
2013 CPC Ch. 4
2013 CPC Ch. 4
2013 CPC Ch. 4
/Flow Rate
2013 CALGreen Div. 4.3
2013 CALGreen Div. 4.3
2013 CALGreen Div. 5.3
Single -Family
Multi -Family
Commercial
Residential
Residential
Water Closets
Exceed 1.6
Single flush toilets: 1.28 gallons/flush
(Toilets)
Gallons/flush
Dual flush toilets: 1.28 gallonstflush effective flush volume (the composite,
average flush volume of two reduced flushes and one full flush
Urinals
Exceed 1.0
0.5 gallons/flush
Gallons/flush
Showerheads
Exceed 2.5
2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of
gallons per minute
U.S. EPA WaterSense Specification for Showerheads
(A hand-held shower is considered a showerhead.)
For multiple showerheads serving one shower, the combined flow rate of all,
showerheads and/or other shower outlets controlled by a single valve shall not
exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to
allow only one shower outlet to be in operation at a time.
Faucets —
Exceed 2.2 gallons
Maximum 1.5 gallons per
Within units:
0.5 gallons per minute @ 60
Lavatory
per minute
minute @ 60 psi; minimum
Maximum 1.5 gallons
psi
Faucets
0.8 gallons per minute @
per minute @ 60 psi;
20 psi
minimum 0.8 gallons
per minute @ 20 psi
In common and public
use areas: 0.5 gallons
per minute @ 60 psi
1.8 gallons per minute
60 si
Faucets —
Exceed 2.2 gallons
1.8 gallons per minute @
1.8 gallons per minute
1.8 gallons per minute @ 60
Kitchen
per minute
60 psi
@ 60 psi
psi
Faucets
May temporarily increase
May temporarily
up to 2.2 gallons per
increase up to 2.2
minute @ 60 psi, and must
gallons per minute @
default to maximum
60 psi, and must
1.8 gallons per minute @
default to maximum
60 psi
1.8 gallons per minute
Where faucets meeting
@ 60 psi
the above are unavailable,
Where faucets meeting
aerators or other means
the above are
may be used to achieve
unavailable, aerators or
reduction.
other means may be
used to achieve
reduction.
' d be ded
1. 1f the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, itis not require to upgra .
SB407 2015doc revised 02/04115
Install one 240 Volt 40 Amp dedicated circuit with an owner -
provided EV charger to the immediate right of the existing main
electrical panel for EV charging. This circuit and charger will
provide up to 32 continuous amps for charging. Surface -
mounted 3/4" MM flex w/ #8 THWN conductors & #10 THWN
ground will be used to route the circuit from the main outdoor
electrical panel to the new EV charger location.
200A Main Panel (E) Garage
w/ 40A breaker (N)
3/4" NM Flex (N)
#8 THWN Conductors (N)
#10 THWN ground (N)
rovironment EV Charger (N)
Driveway
Miko Langberg Page I
Mike Langberg
10340 Byrne Avenue
Cupertino CA 95014
(408) 366-0845
RECEIVED
COMMUNITY DEVELOPMENT DEPARTN
BURYL U„ U L=2W. u1EIRTN
AFIFIROVED
This set of p(an s and sf+esrf cati2ms MUST be kept at lh fa t'l
Site dwing I vt c to inaa e any ch an as or
sl[a,� Hairs a ~ r rk v < t Nfrnirr, w itlsncat al�r vel
T'Y'h* ctarrypi��,c,fttl.
ing
lan and
abons 151-011 1 1401 Ito
� a r of thi"20iJr �+ is Qaiarri° v l aP the vi IWatinn+a6IT
i.rr vi,, on of any City 016iancc uu StKtta;
REVIEVVED.. � R-COLYE
ATE
Revie",p 14c� r
ryi
qj
Residential Electrical Load Calculation
Site Location.
Prepared by
t L L O W
Mike Langberg
Willow Glen Electric, Inc. L p
10340 Byrne Avenue
r
PO Box 8430 L E C T J31 C
Cupertino CA 95014
San Jose, CA 95155
(408)366-0845
(408[289-9725-afflce
General Lighting and Receptacle Loads [220.12]
3 watts per ft' x 1,881 =
5,643
Small -Appliance Branch Circuits 1220.52(A), 210.1(C)(1)]
1,500 watts
x 2 =
3,000
Laundry Branch Circnit{5) 1220.52(B), [210.11(C)(2)]
1,500 watts
x 1 =
1,500
10,143
Fastened -In -Place
Appliances Kitchen
Bathls)
Outlsde/Miscellaneous
[220.53] Refrigerator(s) = 780 Instant Hot H20(s) =
Exhaust Fan(s)
=
Hot Tub =
Dlshwasher(s) = 960
Hood Exhaust(s) =
Jacuzzi Tubs)
=
Pool Equipment = 5,760
Garbage Dlsposal(s) = 60D
Gas Ranges) =
Radiant Heating
=
Central Vacuum =
Mlcrowave(s) = 1,200
Gas oven(s)
Steam shower
=
Sewage Ejector =
Trash Campactor =
WineFridge(s) =
Sauna
=
90A Circuit =
Steamer =
-
=
Garden Shed =
Total Fastened -in-place Appliance Load
9,300
Clothes Dryer(s)[220,54]
80% x
240
x
Derating
Volts
Amps
5,000
OR
Name Plate Rating
of Clothes Dryer
= 5,000
Ranges, Ovens, Cooktops, and Other Household
Cooling Appliances [220.55]
80% x
240
x 30 =
5,760
Derating
Volts
Amps
AND/OR
Name Plate Rating of Cooking Appliances
=
Heating or Air -Conditioning System (Compare the
heat and A/C, and omlt the smaller.) [220.60]
Air Handler/Furnace
115
x 6.0 =
Volts
Amps
Air Conditioners
5,970
551A x
240
x 40 =
Derating
Volts
AND / OR
Name Plate Rating of Air Handler
& AC Units
=
Total Volt -Ampere Demand Load [220.831
Greater of
Air-conditioning Equipment
5,970
x 100% =
5,970
Electrlc Space Heating
-
x 100% =
First BkVA of all other loads
8,000
x 100%
8,000
Remainder of all other loads
22,203
x 40% =
8,881
22,851
Total
Current Minimum Amperes
22,851 +
240 = 95,2
Current Minimum
200 Amps
(voltage) (minimum amperes)
17 Size Service or
Feeder 1240.6(A)]
currently
Electric Vehicle [625.14]
125% x
240
x 32 =
9,600
Continuous Load
Volts
Amps
Minimum Amperes with Added Load
Minimum size
Divide the total 32,451 +
240 - 135.2
20 Service or Feeder
200 Amps
volt-amperes by
(voltage) (minimum amperes)
w/ Added Load
with added load
the voltage.
[240.6(A)]
NOTES
All References are to 2014 National Electrical Code.
L
4 O
O 9
'E 4+
O �
O N-
O N
U i
M
N 41
O •�
+t+ td
Q
C
O O N
an U
r
O V
Co Z
U O L
N
a CD
CL to
L)
N V 0
M 0 >
OMC j "�
> 4� LLI
U
LU y
m
uj
O
E 41 W
f�
O �
O aj
L fn U_
Q TL
4- U
Q
m�
�— N C�
41
N 21
N O
00
O 0
N N
era
N
Oj
CO
q
N N
4
C O
E U
Q CU
L
Q �
O
lh
LO
m
CD
rr
C:
C
W U)
Y N
i�
C:
y
L U
a_7co
N
>
O
U
Or
O
E
LU Ca
0
:3
0 O
Q
O fC
Q s.
L O
O
C)
CD4
10
-0
O Vi
t
C13 O
N -0
(0 �}
V N
N c!i :3
3 C
N
_r_ W CLO-
N
'
..0
0
—1 is
4bCJ
v
N �
O U
CD r
O L O
4) (D c -0
-0-'3
=E7 O
4-1 LUO L <
m .O
O
� 4�
4� CD
U
C
ui
L) .Q 4Z
z +.j
L)
41
N 21
N O
00
O 0
N N
era
N
Oj
CO
q
N N
4
C O
E U
Q CU
L
Q �
O
lh
LO
m
CD
rr
FEATURES
• Industry standard SAE. -J1772 connector
• Auto restart in event of power outage
• Americans with Disabilities Act (ADA) compliant
installation
• Integrated cable stowage
• Underwriters Laboratory (UL) listed
• Breakaway safety cable
• Optional pedestal mount configurations
• Network communication options (EVSE-RS+)
SERVICE AND INSTALLATION
• Expanding network of independent
certified, trained electricians*
• Convenient customer site assessments and installation
• Electricians with local code and permitting knowledge
SPECIFICATION
Connector
Voltage
Frequency
Output Current
EVSE-RS
SAE J1772 compliant
208VAC to 240VAC
60/50Hz
30A max
Input Current
40A max
Operating Temperature
-22°F to 122°F
-30°C to 50°C
Storage/Transit Temperature
-40°F to 1407
-40°C to 60'C
Relative Humidity
Up to 95%
non -condensing
Dimensions
12" x 12" x 8"
(approximate)
Weight
10 lbs. (excl. cable)
Cord Length
Up to 25` available
Enclosure
NEMA 3R
Regulatory Compliance
UL, cUL, CE, CTick
listed
Information and specifications subject to change.
02011 AeroVironment:, Inc.
15 0111_10147
The EVSE-RS Charging Station charges all SAE J1772 -compliant
vehicles— includ'ng both electric vehicle (EV) and plug-in hybrid
(PHEV) models -- in the convenience of the home garage, workplace,
condominium, apartment, or retail parking structure. The Home
Charging Station safely and reliably delivers AC power to the
vehicle's on -board charger and features a weather -resistant NEMA 3R
enclosure for indoor and outdoor installations,
The EV Charging Station can be installed by one of our independent
certified licensed electricians who also facilitate necessary permitting
and inspection, and provide information about EVSE-RS use to the
customer. An optional module is available to enable WiFi, Zigbee, or
cellular network connectivity.
" Instaflation services avairable in certain areas,,
contact AV for additional information.