B-2017-0058 CITY OF CUPERTINO BUILDING PE ' T BUILDING ADDRESS: CONTRACTOR: P RMIT NO:B-2017-0058 10340 BYRNE AVE CUPERTINO,CA 95014-2814(357 15 075) WILLOW GLEN ELECTRIC INC SAN JOSE,CA 95155 OWNER'S NAME: LANGBERG MICHAEL DAVID AND GORDON DEBRA ELL D•TE ISSUED:01/10/2017 OWNER'S PHONE:408-366-0845 P;ONE NO:(408)289-9725 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT I 0: License Class C-10 Lic.#591918 Contractor WILLOW GLEN ELECTRIC INC Date 04/30/2018 XBLDG —ELECT — 'LUMB I hereby affirm that I am licensed under the provisions of Chapter 9(commencing —MECH X RESIDENT =COMMERCIAL with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N)EV CHARGING STA ION(40 AMP)GARAGE I hereby affirm under penalty of perjury one of the following two declarations: t I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. bm I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: V.luation:$990.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number: 0.cupancy Type: and state laws relating to building construction,and hereby authorize 35715 075 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXP S IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 D' S OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. 180 DAYS FRO LAST CALLED INSPECTION. ,Signaturz i J Date 01/10/2017 Issued by:Kim Dunbar vv �� Date:01/10/2017 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS; following two reasons: All roofs shall be inspected.rior to any roofing material being installed.If a roof is 1. I,as owner of the property,or my employees with wages as their sole installed without first obta'.'.g an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant: contractors to construct the project(Sec.7044,Business&Professions Code). Date:01/10/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF CO RINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARD n US MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health 8z Safe Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with t a e Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Se tion 25532(a)should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally,sho Id I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance wi h the Cupertino Municipal Code,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safe Code,Sections 25505,25533,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. C / Owner or authorized aged: .� APPLICANT CERTIFICATION Date:01/10/2017 I certify that I have read this application and state that the above information is CONS UCTION LENDING AGENCY correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is°construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for which this per it is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARC TECT'S DECLARATION Code,Section 9.18. I understand my plans shall be used as public records. Licensed Signature Date 01/10/2017 Professional (De thr/v6eK-6 \.1 ALTERNATIVE ENERGY PERMIT APPLIC PION I COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISIOAE 1,I?rr 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 llPER"!• Intl (408)777-3228• FAX(408)777-3333•buii� 'Is t, aaa;.il'c,,c,t' CPROJECT ADDRESSII0 3` :0 r/i ,5469-1(444.... APN# 35 5—.m 0 45 �F j� OWNER NAME is �J $� PHONE 3 � � V� MAIL°' ` �� � J jam• 3 rite �/J c STREET ADDRESS /p .f�y a°a V CITY STATE,-ZIP ,. ,a -`"0/`,.,✓ FAX 41- CONTACT NAME Mark Londre PHONE (408)289.9725 -MAIL ""ffice@willowglenelectric.com STREET ADDRESS P. O. Box 8430 CITY,STATE,ZIP San Jose, CA 9.155 FAX(408)289-9725 ❑OWNER 0 OWNER-BUILDER 0 OWNER AGENT CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITEC 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME Mark Londre LICENSE NUMBER 591918 LICENSE 'E ^-10 BUS.LIC# 15897 COMPANY NAME Willow Glen Electric, Inc. E-MAIL office@willowglenelec ric.com FAX (408)289-9725 STREET ADDRESS P. O. Box 8430 CITY,STATE,ZIP San Jose, CA 9',155 PHONE (408)289-9725 ARCHITECT/ENGINEEER NAME N/A LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF 4 SFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: 0 Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE 0 Yes 0 No ❑SOLAR PANELS it ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 0 HER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): T a;W;:''`,- DESCRIPTION OF WORK /, o Electric Vehicle .Charging Circuit:� (' ) -10 ee.et jCI-CC-Z-444 k. W/AIA,'&14 4 f, ,A07/PLe -C t `te `.dt- .e i'_- -X.1.4.ki - 'a +�•�. Le b/id :0 • -fr. ir ric; DB .....)0, ,......)_ By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building conti n I tho'ze rep tatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: %'/(44 R �twi Date: i- f / - SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY W : R-THE-COIJNTER ❑.:EXPRESS=. 6 � /j, %- . rJ � (/ 0 LARGE ck ❑ MAJOR - PVApp_2011.doc revised 03/16/11 uuci,5oiW_i Mnvewpe w: ytSVbSbI.S-bZ2525-4251 r-yyLt-Gt1 F5ZDC6289 SMOKE/ CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 90300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildina0cupertino.orct Permit No,B-2017-0058 Address 10340 Byrne Avenue, Cupertino #of Alarms Smoke: 5 Carbon Monoxide: 1 PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SI =NSD AND R ; T, URNED TO THE BUILDING DIVISION , PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X, Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s). may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal, of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section 8314 and CBC Sectionsi 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of ;the above -referenced property, I hereby certify that the alarms) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. 1 have read and agree to comply with the terms and conditions of this statement Owner (or Owner Agent's) Name: Dousignea by: Mike Lan ber si natur ...!!!u �... JAMAMA ...................Dat /27(20 Contractor Name: WB796318F0451... Sinature................................................................... Lic.#...................................... Date:................... Smoke and CO form.doc revised 03118114 .7 DocuSign Envelope ID: 980635C3-6288-481 F-992E-CE1 F52DC6289 CUPERTINO WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 - building@cuoertino.orq Owner Name, Mi ke Lan berg Permit No. B-2017-0058 Address 10340 Byrne Avenue, Cupertino, CA 95014 PERMIT CANNOT BE EINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN S +" AND FT 1 RNI D TO THE BUILDING DIVISION Please refer to the attached California Civil Code Sections 1101.1 --1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature:DocuSigned by: Date: 1/27/2017 F-1No Go to Question 2.E6t3o1BaF0*451,w1 .. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. DocuSigned by: Owner' Signature:�� ❑ No Go to Question 3. 8A66796318F0451... Date:1/27/2017 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature:Doeusignedby, Date: 1/27/2017 ❑ No Go to Question 4.E631BFOi5l ... 4. Is your real property built and available for use or occupancy on or before January 1,1994? ❑ No My real property is built and available for use or occupancy after. January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. DocuSigned by: Owner' Signature: NLL t0A*trj Date: 1/2 7/2017 ❑ Yes My real property i san6 svoiiable for use or occupancy on or before January 1, 1994. Civil Code Sections I 10 1. 1 through 1101.8 apply. Refer to the attached. ❑ My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing .fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a inultifaniily residential real. property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB407 2015.doc revised 02104115 y DoceSig"`n Envelope ID: 980635C3-6288-481 F -992E -CEI F52DC6289 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements. and that the water-conservir&iftW yla fixtures comely with the requirements as indicated in the table below. Owner's (or Owner Agent's) Signature] NUt: t, ("M _ - Date:-`/ ` ` / "' J- ` 8F0451 Upon completing and signing this Certificate, please return it to the Building Division in order to ttnal your permit. 1. 1f the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, itis not require to upgra . SB407 2015doc revised 02/04115 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixture/ (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallonstflush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all, showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 si Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. ' d be ded 1. 1f the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, itis not require to upgra . SB407 2015doc revised 02/04115 Install one 240 Volt 40 Amp dedicated circuit with an owner - provided EV charger to the immediate right of the existing main electrical panel for EV charging. This circuit and charger will provide up to 32 continuous amps for charging. Surface - mounted 3/4" MM flex w/ #8 THWN conductors & #10 THWN ground will be used to route the circuit from the main outdoor electrical panel to the new EV charger location. 200A Main Panel (E) Garage w/ 40A breaker (N) 3/4" NM Flex (N) #8 THWN Conductors (N) #10 THWN ground (N) rovironment EV Charger (N) Driveway Miko Langberg Page I Mike Langberg 10340 Byrne Avenue Cupertino CA 95014 (408) 366-0845 RECEIVED COMMUNITY DEVELOPMENT DEPARTN BURYL U„ U L=2W. u1EIRTN AFIFIROVED This set of p(an s and sf+esrf cati2ms MUST be kept at lh fa t'l Site dwing I vt c to inaa e any ch an as or sl[a,� Hairs a ~ r rk v < t Nfrnirr, w itlsncat al�r vel T'Y'h* ctarrypi��,c,fttl. ing lan and abons 151-011 1 1401 Ito � a r of thi"20iJr �+ is Qaiarri° v l aP the vi IWatinn+a6IT i.rr vi,, on of any City 016iancc uu StKtta; REVIEVVED.. � R-COLYE ATE Revie",p 14c� r ryi qj Residential Electrical Load Calculation Site Location. Prepared by t L L O W Mike Langberg Willow Glen Electric, Inc. L p 10340 Byrne Avenue r PO Box 8430 L E C T J31 C Cupertino CA 95014 San Jose, CA 95155 (408)366-0845 (408[289-9725-afflce General Lighting and Receptacle Loads [220.12] 3 watts per ft' x 1,881 = 5,643 Small -Appliance Branch Circuits 1220.52(A), 210.1(C)(1)] 1,500 watts x 2 = 3,000 Laundry Branch Circnit{5) 1220.52(B), [210.11(C)(2)] 1,500 watts x 1 = 1,500 10,143 Fastened -In -Place Appliances Kitchen Bathls) Outlsde/Miscellaneous [220.53] Refrigerator(s) = 780 Instant Hot H20(s) = Exhaust Fan(s) = Hot Tub = Dlshwasher(s) = 960 Hood Exhaust(s) = Jacuzzi Tubs) = Pool Equipment = 5,760 Garbage Dlsposal(s) = 60D Gas Ranges) = Radiant Heating = Central Vacuum = Mlcrowave(s) = 1,200 Gas oven(s) Steam shower = Sewage Ejector = Trash Campactor = WineFridge(s) = Sauna = 90A Circuit = Steamer = - = Garden Shed = Total Fastened -in-place Appliance Load 9,300 Clothes Dryer(s)[220,54] 80% x 240 x Derating Volts Amps 5,000 OR Name Plate Rating of Clothes Dryer = 5,000 Ranges, Ovens, Cooktops, and Other Household Cooling Appliances [220.55] 80% x 240 x 30 = 5,760 Derating Volts Amps AND/OR Name Plate Rating of Cooking Appliances = Heating or Air -Conditioning System (Compare the heat and A/C, and omlt the smaller.) [220.60] Air Handler/Furnace 115 x 6.0 = Volts Amps Air Conditioners 5,970 551A x 240 x 40 = Derating Volts AND / OR Name Plate Rating of Air Handler & AC Units = Total Volt -Ampere Demand Load [220.831 Greater of Air-conditioning Equipment 5,970 x 100% = 5,970 Electrlc Space Heating - x 100% = First BkVA of all other loads 8,000 x 100% 8,000 Remainder of all other loads 22,203 x 40% = 8,881 22,851 Total Current Minimum Amperes 22,851 + 240 = 95,2 Current Minimum 200 Amps (voltage) (minimum amperes) 17 Size Service or Feeder 1240.6(A)] currently Electric Vehicle [625.14] 125% x 240 x 32 = 9,600 Continuous Load Volts Amps Minimum Amperes with Added Load Minimum size Divide the total 32,451 + 240 - 135.2 20 Service or Feeder 200 Amps volt-amperes by (voltage) (minimum amperes) w/ Added Load with added load the voltage. [240.6(A)] NOTES All References are to 2014 National Electrical Code. L 4 O O 9 'E 4+ O � O N- O N U i M N 41 O •� +t+ td Q C O O N an U r O V Co Z U O L N a CD CL to L) N V 0 M 0 > OMC j "� > 4� LLI U LU y m uj O E 41 W f� O � O aj L fn U_ Q TL 4- U Q m� �— N C� 41 N 21 N O 00 O 0 N N era N Oj CO q N N 4 C O E U Q CU L Q � O lh LO m CD rr C: C W U) Y N i� C: y L U a_7co N > O U Or O E LU Ca 0 :3 0 O Q O fC Q s. L O O C) CD4 10 -0 O Vi t C13 O N -0 (0 �} V N N c!i :3 3 C N _r_ W CLO- N ' ..0 0 —1 is 4bCJ v N � O U CD r O L O 4) (D c -0 -0-'3 =E7 O 4-1 LUO L < m .O O � 4� 4� CD U C ui L) .Q 4Z z +.j L) 41 N 21 N O 00 O 0 N N era N Oj CO q N N 4 C O E U Q CU L Q � O lh LO m CD rr FEATURES • Industry standard SAE. -J1772 connector • Auto restart in event of power outage • Americans with Disabilities Act (ADA) compliant installation • Integrated cable stowage • Underwriters Laboratory (UL) listed • Breakaway safety cable • Optional pedestal mount configurations • Network communication options (EVSE-RS+) SERVICE AND INSTALLATION • Expanding network of independent certified, trained electricians* • Convenient customer site assessments and installation • Electricians with local code and permitting knowledge SPECIFICATION Connector Voltage Frequency Output Current EVSE-RS SAE J1772 compliant 208VAC to 240VAC 60/50Hz 30A max Input Current 40A max Operating Temperature -22°F to 122°F -30°C to 50°C Storage/Transit Temperature -40°F to 1407 -40°C to 60'C Relative Humidity Up to 95% non -condensing Dimensions 12" x 12" x 8" (approximate) Weight 10 lbs. (excl. cable) Cord Length Up to 25` available Enclosure NEMA 3R Regulatory Compliance UL, cUL, CE, CTick listed Information and specifications subject to change. 02011 AeroVironment:, Inc. 15 0111_10147 The EVSE-RS Charging Station charges all SAE J1772 -compliant vehicles— includ'ng both electric vehicle (EV) and plug-in hybrid (PHEV) models -- in the convenience of the home garage, workplace, condominium, apartment, or retail parking structure. The Home Charging Station safely and reliably delivers AC power to the vehicle's on -board charger and features a weather -resistant NEMA 3R enclosure for indoor and outdoor installations, The EV Charging Station can be installed by one of our independent certified licensed electricians who also facilitate necessary permitting and inspection, and provide information about EVSE-RS use to the customer. An optional module is available to enable WiFi, Zigbee, or cellular network connectivity. " Instaflation services avairable in certain areas,, contact AV for additional information.