Loading...
13020022CITE' OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10411 MENHART LN CONTRACTOR: GEORGE CHANG PERMIT NO: 13020022 OWNER'S NAME: GEORGE CHANG 10751 JOHNSON AVE DATE ISSUED: 05/14/2013 OWNER'S PHONE: 4083219988 CUPERTINO, CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL License Class Lic. # CONSTRUCT ONE STORY RESIDENCE (1878 SQ FT); ATTACHED GARAGE 494 SQ FT; COVERED PORCH 46 SQ Contractor Date FT. I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $355800 performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 37515001.00 Occupancy Type: . ' permit is issued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DA OM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Issued Y`'� granting of this permit. Additionally, the applicant understands and will comply by: Date with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. if a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. OWNER-BU[LDER DECLARATION Signature of Applicant: Date: I hereby affirm that l am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property; am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). [ have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should 1 store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and 1 have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner ��/Z� permit is issued. or authorized agent: -7 ate: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, 1 must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18, J 2 Signature-_ eDate � i� I 6�Q (14 R CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10411 MENHART LN CONTRACTOR: GEORGE CHANG PERMIT NO: 13020022 OWNER'S NAME: GEORGE CHANG 10751 JOHNSON AVE DATE ISSUED: 05/14/2013 OWNER'S PHONE: 4083219988 CUPERTINO, CA 95014 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL 17 COMMERCIAL License Class Lic. # CONSTRUCT ONE STORY RESIDENCE (1878 SQ FT); ATTACHED GARAGE 494 SQ FT; COVERED PORCH 46 SQ Contractor Date FT, A hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions 8/19/2013- REVISION 41- TRUSS CALCS-ISSD 8/29/2013 Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for thg. Sq. Ft Floor Area: Valuation: $355800 performance of the work for which this permit is issued. , 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 37515001.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAY FR M LAST CALLED IN PE TION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply Issued by: Date: with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, 1 agree to remove all new materials for inspection. OWNER -BUILDER DECLARATION Signature of Applicant:_ Date: I hereby affirm that 1 am excmpt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, wil I do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this°h the Health & Safety Code, Secti s 25505, 25533; and 25534. . permit is issued. Owner or authorized agent: � Date: 9z" I certify that in the performance of the work for which this permit is issued, I shall rD not employ any person in any manner so as to become subject to the Worker's V -Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE o CUPERTINO, CA 95014-3255 (408) 777-3228 ^ FAX (408) 777-3333 • build ingna-cupertino. orq ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION/ DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS ® 4 e ` APN N OWNER NAME PHONE E-MAIL STREET ADDRESS CITY, STATE, ZIP FAX CONTACT NAME 1� A ,�-,y .. 4 � PHONE a + �t E-MAIL"C - 0— we- v s&m. r•6a CITY, STATE, ZIP SAN A Sa 5S , f�491Or STREET ADDRESS, ,4 p_ pe�r1C/r11 V 3 �1% CA 1❑"ENG "TE'ENANT ❑ OWNER ❑ OWNEiRR--BUUIL9 DER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTO�R?AGGEENTT Vr ARCHI ECTT NEER❑ DEVELOPER ❑ CONTRACrORNAME LICENSENUMBER LICENSETYPE BUS.LICH COMPANY NAME E-MAIL FAX STREET ADDRESS CFFY, STATE, ZIP PHONE ARCHITECT NaGINEERNAME o� LICENSE NUMBER BUS. LIC # VAI FAX COM ANY AME E-MAIL 1 Qs:, STREET ADDRESS CfI-Y, STATE, ZIP PHONE 24 CAC�� 71 DESCRIPTION OF WORK !mus EXISTING USE PROPOSED USE CONSTR TYPE # STORIES USE TYPE- OCC. SQ.FT. VALUATION (S) EXISTG AREA NEW FLOOR AREA DEMO AREA TOTAL NET AREA low BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKIPORCH AREA GARAGE AREA: DETACH ❑ ATTACH I #D WELLING UNITS: IS ASECOND UNIT [I YES SECONDSTORY []YES BEING ADDED? []NO ADDITION' []NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES ( g I " :,� TOTAL VALUATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each of the following: 1 am the property owner or authorized Agent to act on the property owner's behalf. 1 have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buil ' cons ae atives of Cupertino to enter the above -identified roperty for inspection purposes. Signature of Applicant/Agent: A Date: SUPPLEMENTAL INFORMAT Q IRED PLAN Ci� ROWING S*t New SFD or Multifamily dwellings: Apply for demolition permit for;. _ existing building(s). Demolition permit is required prior to issuance of buildi R-T,HE•COUNTER BUILDING PUAN REVIEW - permit for new building. -EXPRESS - ❑ r PLANNING PLANREVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure "❑ sTnNDaRD t ❑'rtiBLrcwolires form if any Hazardous Materials are being used as part of this project. ❑ 'LARGE,- .,;Fr>tE DEPT Copy of Planning Approval Letter or Meeting With Planning prior to _ submittal of Building Permit application. p ntAJox = ❑ .sANIT ARY SEWER ms�Rlcr - - ❑ ENVIRONMENTAL HEALTH 201 Ldoc revised 06/21111 NEW CONSTRUCTION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE ^ CUPERTINO, CA 95014-3255 (408) 777-3228 o FAX (408) 777-3333 ^ buildingCcDcupertino.org ❑ ADDITION ❑ ALTERATION/T1 ❑ REVISION / DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS / jj/J /� / y� �f/G� APN # J- ` / r^ OO OWNER NAME PHONE meg. S$ E-MAIL d� STREET ADDRESS /aA /G�/rd/IL � � CITY, STATE, ZIP /+ L^�O nfi sv FAX t� CONTACT NAME //F 5 PHONE p_3 `, i 9 9 p e EMAIL J s. G �q STREET ADDRESS CITY, STATE, ZIP 49 f -S /3 FLAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE EER NAME LICENSE NUMBER BUS. LIC # E-MAIL FAX 5DESCiUPTION CITY, STATE, ZIP PHONE ORK Alew ' ew-pe//��„,,pj�A/JQI�}, (,/✓) /U%,. RePd-k9'1�' %( ►iL['�d'I% '', (./�// S�JY /"i' rl� � CRd�""�0'+ o/0 -X C-0 Vi"X6467-ei C 2, �'/,1 ,y- 41%, , C/” �� EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES u -4 /-� �` / USE OCC. VALUATIONEXIST($) AREAL NEW FLOOR AREA DEMO AREA TOT NEfAL , /TYPE /S�Q.FT, � �70 i (2• BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKTORCH AREA GARAGE AREA: DETACH �! D. 4W ATTACH # DWELLING =S: IS A SECOND UNIT ❑ YES SECOND STORY YES / BEINGADDED? NO ADDITION? 70 17 PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF PLANNING ADPL # I�PLANNING APPROVAL LETTER IS THE BLDG AN ❑ YESREC NO EICHLER HOME? NO E BY. '` - `" ` `�� `d TOTAL VALUATION: �" z �� By my signature below, I certify to each of the following: I am the property owner or aut todZe4gent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of' Vork and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buildingconstruction. I auth a representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: �, / �j i; Date: SUPPLEMENTAL INFORMATION REQUIRED _ New SFD or Multifamily dwellings: Apply for demolition permit for , ❑ 01 ER TIIE COUNTER UILD NG PLA\ REVIEW existing building(s). Demolition permit is required prior to issuance of buildings permit for new building. Q- EaPRESS c PLANING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure il sTaNDARn- , PUBLiC3\;ORKS r; form if any Hazardous Materials are being used as part of this project. �r Copy Planning Approval Letter Meeting Planning 0.; LARGF� U, �r FIRE DEPT <z ' _ of or with prior to I]DIAJORSITARY SER DISTRICT:. submittal of Building Permit application. j❑k tY� s -+C ElVl'IRONI3ENTAV'H ALTH BldgApp_201 Ldoc revised 06/21/11 CITY OF CUPERTINO 11 FEE ESTIMATOR — BUILDING DIVISION im,ADDRESS: 10411 menhart In DATE: 08/1912013 REVIEWED BY: mendez ;blec:h. Permit Fee: APN: BP#: I�R_rY `VALUATION: 1$9,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: New Construction PRIMARY SFD or Duplex USE: PENTAMATION 1 GENRE PERMIT TYPE: Elec, Insp, Fee: Revision #1- truss calcs 1SW_C00% $0.00 NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc). These fees are based on the nreliminary information available and are only an estimate Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 711/12) ,Mach. Pion Check Phnnh. Plan Check Elec. Plan Check ;blec:h. Permit Fee: Plarmb. Permir Fee: Elec•, Permit Fee: Other rllech. Insp.Ll Other Plumb Insp,Li Other Elee. Insp. Ll Ilech, Insp. Fee: Plumb. hr.cp. Fee: Elec, Insp, Fee: NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc). These fees are based on the nreliminary information available and are only an estimate Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 711/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: Hourly Only? 0 Yes 0 No $0.00 hours Plan Check, Hourly $278.00 1STPLNCK Suppl. PC Fee: 0 Reg. () OT 1 0.0 1 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: IBCONSTAXR 0 # newnits$0.00 Administrative .Fee: 0 0 Work Without Permit? ® Yes (E) No $0.00 Advanced Planning .Fee: $0.00 Select a Non -Residential 0 Building or Structure O i Travel Docutnentarion Fees: Strony, Motion Fee: IBSEISMICR $0.90 Select an Administrative Item Bldg; Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $1.901 $278.00 TOTAL FEE: $279.90 Revised: 0710112013 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION OCCUPANCY TYPE: ADDRESS: 10411 MENHART LN DATE: 02/06/2013 REVIEWED BY: Mendez PC FEE ID APN: BP#: /,30,`z0o';z o, *VALUATION: 1$355,800 'PERMIT TYPE: Building Permit PLAN CHECK TYPE: New Construction }PRIMARY . ' 2nd Unit? � Yes • No USE: SFD or Duplex PENTAMATION PERMIT TYPE: 1 R3SFD i WORK CONSTRUCT 1 STORY SFDWL 1,878 SQ FT ATTACHED GARAGE 494 SQ FT PORCH 46 SQ FT SCOPE AND DECK AREA 37 SQ FT OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA f.) PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,III-B,IV,V-B _LS. 2,455 $2,755.70 1R3PLNCK $2,579.95 1R3INSP Suppl. Insp. Feer Reg. OT 0 0 hrs $0.00 [PME Unit Fee: $0.00 PME Permit Fee: $0.00 71 Construction Tax: 1BCONSTAXR 1 # new units $6 9 Administrative .Fee: E) Work Without Permit? 0 Yes (F) No $0.00 Advanced Planning Fee: IPLLONGR $319.15 Select a Non -Residential Q Building or Structure Truvel Document(vion Fees: TOTALS: 2,455 $21755.70 Select an Administrative Item 1 $2,579.95 $15.00 NOTE: This estimate does not include fees due to other Departments ('tie. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc). These fees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 711112) ititeeh, Plan (heck Plumb. Nun Check Elcc..Plun C'he>ck Me<;h. Pc:rrnitl`Ce: Plumb. FUEL: F,lec. PernlitFee: other Alech. Insp.' 01her Plumb Insp.Ll Ocher Flee. Insp. Ilech. Imp. 1 ee: PIUMb. lisp. Tee: Gies. Ins/), Fee: NOTE: This estimate does not include fees due to other Departments ('tie. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc). These fees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 711112) FEE QTY/FEE MISC ITEMS Plan Check Fee-.. $2,755.70 Select a Misc Bldg/Structure or Element of a Building Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $2,579.95 Suppl. Insp. Feer Reg. OT 0 0 hrs $0.00 [PME Unit Fee: $0.00 PME Permit Fee: $0.00 71 Construction Tax: 1BCONSTAXR 1 # new units $6 9 Administrative .Fee: E) Work Without Permit? 0 Yes (F) No $0.00 Advanced Planning Fee: IPLLONGR $319.15 Select a Non -Residential Q Building or Structure Truvel Document(vion Fees: Strom Motion Fee: IBSEISMICR $35.58 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $15.00 SUBTOTALS: $6,334.67 $0.00 TOTAL FEE: 1 1 $6,334.67 Revised: 01/01/2013 Building Department City Of Cupertino 10300 Tone Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 JOB ADDRESS:10411Menhart Ln PERMIT # 13020022 OWNER'S NAME -.George Chang PHONE #(408)406-1006 GENERAL CONTRACTOR: BUSINESS LICENSE # ADDRESS: CITY/ZI PCODE: *Our :municipal code requires ai] businesses worMng in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY UNSPECTUON(S) WILL BE SCHEDULED UNTIL THE GENERAL, CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUJPIERTINO BUSINESS LICENSE. U am not using any snubcoantractors: Signature Date Please cheek applliicable subean timetoars and c0mplete flue ff0owiing information: V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Great Land Construction Corp 23608 Cement Finishing All Bay Concrete Electrical Ali's Construction & Remodeling Inc. 28677 Excavation Ali's Construction & Remodeling Inc. 28677 Fencing Flooring / Carpeting Great Land Construction Corp 23608 Linoleum / Wood Glass / Glazing Heating Great Land Construction Corp 23608 Insulation Ali's Construction & Remodeling Inc. 28677 Landscaping Lathing Masonry Painting / Wallpaper- Great Land Construction Corp 23608 Paving Plastering Plumbing Ali's Construction & Remodeling Inc. 28677 Roofing Ali's Construction & Remodeling Inc. 28677 Septic Tank Sheet Metal Sheet Rock Ali's Construction & Remodeling Inc. 28677 Tile Great Land Construction Corp 23608 ��) I z�� ®�roantractor ignatu Date 2010. CALGREEN RESIDENTIAL CHECKLIST — MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT o BUILDING DIVISION CtJPERTINO ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL ", 0 10300 TORRE AVENUE o CUPERTINO, CA 95014-3255 ,ll� (408) 777-3221 FAX (408) 777-3333 < buildinipcuone.ora �Jt PURPOSE; The 2010 CaiGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings, dormitories, condominiums, shelters, congregate residences, employee housing, factory -built housing and other types of swellings with sleeping accommodations and new accessory buildings associated with such uses. Existing site and landscaping Improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: !"I: ,04, ...ee - ►o ar! Project Address: /®q ®A /�% �Qy -a—�„dP.Tho� Project Description: s7b g.:? for P 8 s Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the 2010 California Green Building Standards Codes to verify and assure, that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with.the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1- Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. MANDATORY FEATURE OR MEASURE 4.104.1 A site plan and inventory of the site is developed and used to minimize site disturbance In order preserve desirable existing natural resources and . minimize future adverse effects on the proposed structure. 4.106.2 A plan is developed and implemented to manage storm water drainage during construction. :olumn 2 Project W In Verification 4.106.3 The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how site grading or a drainage system will manage all surrace water flows. Page 1 of S � CalGreen_2010.doc revised 0&27/11 A4.2 ENERGY EFFICIENCY A4.3 WATER EFFICIENCY AND CONSERVATION F.3 A4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY ■ X A4.5 . t QUALITY i 4.803.1 Install only a direct-vent sealed-combustion gas or sealed wood- L7 buming fireplace, or a sealed woodstove. . 4.504.1 Duct openings and other related air distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. 4.604.2.2 Paints, stains and other coatings shall be compliant with VOC limits. 4.604.2.3 Aerosol paints and other coatings shall be compliant with product ® [� weighted MIR Limits for ROC and other toxic compounds. 4.504.2A Documentation shall be provided to verify that compliant VOC limit ® �' finish materials have been used. 4.604.3 Carpet and carpet systems shall be compliant with VOC limits. ® ❑ 4.504.4 Fifty (50) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance © ❑ Schools (CH PS) Low-emitting Materials List or be certified under the Resilient Floor Covering At / O Institute (RCFI) FloorScore program. 4.504.5 Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall comply with low formaldehyde ® [� emission standards. 4.606.2 Vapor retarder and capillary break is installed at slab on grade foundations. 4.605.3 Moisture content of building materials used in wall and floor framing is checked before enclosure. Page 3 of 5 CalGreen_2010.doc revised 08127111 4.506.1 Exhaust fans which terminate outside the building are provided in every bathroom. 4.507.1 Whole house exhaust fans shall have insulated louvers or coven; which close when the fan is off. Covers or louvem'shall have a minimum ® ❑ � insulation value of R-4.2. 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent 2. Size duct systems according to RCCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according -to ACCA 36-S (Manual S) or equivalent. 702.1 HVAC system installers are trained and certified in the proper installation of MVAC systems. 702.2 The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the discipline they inspect and verify. 703.1 Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 Ca1Green_2010.doc revised 08/27/11 BUILDING ENERGY ANALYSIIS REPORT CUPERTINO f PROJECT: ?� MAR 19 2013 REVIEWED FOR CODE COMPLIANCE Mr. Chang's Redisence 10411 Menhart Lane Reviewed By: Cupertino, CA 95014-3679 Proyec t Desugner: Mr. Sy Cheng Tsai RCUSA Corporation ,-,-g 2050 Concourse Drive, #50 , San Jose, CA 95131 Q 408-321-9988 Hepor4 Prepared by: Mark Chu Mark Chu & Associates, 1141 S. Stelling Road Cupertino, CA 95014 (408) 255-4804 Job Humber: ki RC120944 Daae 2/6/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 5.1 b Ener Soft User Number: 4970 RunCode: 2013-02.06T09:07:59 ID: RC120944 PERFORIMIANC E CERTIFICATE. Resiidentiial] Part 1 of 5 CSF -11 R Project Name Mr. Chang's Redisence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/6/2013 Project Address 10411 Menhart Lane Cupertino California Energy Climate Zone2!!1,878 CA Climate Zone 04 nd. Floor Area Addition n/a # of Stories 1 FIELD INSPECTION EN1ERGY CHECKLIST KLI1ST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see part 2 of 5 Status Floor Wood Framed w/Crawl Space R-19 1,878 New Wall Wood Framed R-13 1,684 New Door Opaque Door None 51 New Roof Wood Framed Attic R-30 1,868 Radiant Barrier New FENESTRATION U- Orientation Area(fo factor [exterior STC Overhang Sideffins Shades Status Front (S) 99.5 0.370 0.32 none none Bug Screen New Rear (N) 61.5 0.370 0.32. none none Bug Screen New Left (W) 38.0 0.370 0.32 none none Bug Screen New Right (E) 81.0 0.370 0.32 none none Bug Screen New Skylight 8.0 0.370 0.29 none none None New Skylight 2.5 0.550 0.67 none none None New HVAC SYSTEMS Ct . Heating Vein. Effff Cooling Min. Effff Thermostat Status 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION (Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Basement 6.0 New WATER HEATING Ct . Type Gallons Min. Effff Distribution Status 1 Small Gas 50 0.61 No Pipe Insulation New Ener Pro 5.1 )y Ener Soft User Number: 4970 RunCode: 2013-02-06T09:07:59 ID: RC120944 Pa2e 2 of 12 PERFORMANCE C CERT f CATEe ResWeMW (Part 2 of 5) CF -1R Project Name Mr. Chang's Redisence Building Type ®Single Family 13 Addition Alone ❑ Multi Family 13Existing+ Addition/Alteration Date 2/6/2013 SPECIAL FEATURES URES II SPE IWM CHEC KLIIS Ij The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-30 Roof Attic with Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS G EQUINED ` ERIIMATIION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number: 4970 RunCode: 2013-02-06709:07:59 ID: RC120944 Pae 3 of 12 I ERFORfl�ANC E C ERT11MCA`[ E: G` esiliden-RW (Part 3 of 5) CF -I R Project Name Building Type RlSingle Family ❑ Addition Alone Date Mr. Chang's Redisence ❑ Multi Family ❑ Existing+ Addition/Alteration 2/6/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 23.99 16.91 7.09 Space Cooling 7.22 5.16 2.06 Fans 4.82 3.90 0.92 Domestic Hot Water 19.42 18.73 0.70 Pumps 0.00 0.00 0.00 Totals 55.46 44.69 10.76 Percent Better Than Standard: 19.4% BUIL OONG COO 1MPLUES o NO HERS VERRFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 577 100 Fuel Available at Site: Natural Gas (tM 430 38 Raised Floor Area: 1,878 (N) 577 62 Slab on Grade Area: o (E) 430 81 Average Ceiling Height: 10.0 Roof 1,876 11 Fenestration Average U -Factor: 0.37 TOTAL: 291 Average SHGC: 0.32 Fenestration/CFA Ratio: 15.5% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. DoCUmentetion Author Company Mark Chu 8 Associates Cri� C �rl�^- 2/6/2013 Address 1141 S. Stelling Road Name Mark Chu City/State/ZipCity/State/Zip Cupertino, CA 95014 Phone (408) 255-4804 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Mr. Sy Cheng Tsai 61�6�3 Address RCUSA Corporation Name L� City/State/Zip 2050 Concourse Drive, #50 , San Jose, C,4 Phone 408-321-9968 Signed License # Date Ener Pro 5.1 b Ener Soft User Number: 4970 RunCode: 2 013-02-0 6 70 9:07:59 ID: RC120944 Page 4 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Mr. Chang's Redisence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/6/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Floor 1,878 0.037 R-19 0 180 New 4.4.1-A4 1st Floor Zone Wall 444 0.102 R-13 180 90 New 4.3.1-A3 1st Floor Zone Door 34 0.500 None 180 90 New 4.5.1-A4 1st Floor Zone Wall 516 0.102 R-13 0 90 New 4.3.1-A3 1st Floor Zone Wall 375 0.102 R-13 270 90 New 4.3.1-A3 1st Floor Zone Door 17 0.500 None 270 90 New 4.5.1-A4 1st Floor Zone Wall 349 0.102 R-13 90 90 New 4.3.1-A3 1st Floor Zone Roof 1,868 0.031 R-30 0 22 New 4.2.1-A20 1st Floor Zone FENESTRATION SURFACE DETAILS T e Area U-Factor SHGC Azm Status Glazin T e Location/Comments Window 4.5 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vinyl/Low-E 1st Floor Zone Fr Window 15.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyllLow-E 1st Floor Zone Window 9.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vin I/Low-E 1 st Floor Zone Window 7.5 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyllLow-E 1 st Floor Zone Window 9.0 0.370 NFRC 0.32 NFRC. 180 New IWC 5300 VinyllLow-E 1 st Floor Zone 6 Window 15.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vinyl/Low-E 1 st Floor Zone 7 Window 4.5 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyULow-E 1 st Floor Zone 8 Window 30.01 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyllLow-E 1 st Floor Zone 9 Window 5.01 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyllLow-E 1st Floor Zone 10 Window 8.01 0.370 NFRC 0.32 NFRC 0 New IWC 5300 VinyllLow-E 1 st Floor Zone 11 Window 12.0 0.370 NFRC 0.32 NFRC 0 New IWC 5300 Vinyl/Low-E 1 st Floor Zone 12 Window 8.0 0.370 NFRC 0.32 NFRC 0 New IWC 5300 VinyllLow-E 1st Floor Zone 13 Window 4.5 0.370 NFRC 0.32 NFRC 0 New IWC 5300 VinyllLow-E 1st Floor Zone 14 Window 12.0 0.370 NFRC 1 0.32 1 NFRC 0 New IWC 5300 VinyllLow-E 1st Floor Zone 15 Window 12.0 0.370 NFRC 1 0.32 1 NFRC 0 New IWC 5300 VinyULow-E I 1st Floor Zone 16 Window 5.0 0. 3701 NFRC 1 0.32 NFRC 1 0 1 New I IWC 5300 Vinyl/Low-E 1st Floor Zone (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 4970 RunCode: 2013-02-06709:07:59 ID: RC120944 Pae 5 of 12 C ER1 MCATE OF CONPLIANC E: ResidenUall (Part 4 of 5) CP -1 R Project Name Mr. Chang's Redisence Building Type m Single Family ❑Addition Alone 7n. ❑Multi Family ❑Existing+ Addition/Alterati/6/2013 ate OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 30.0 0.370 1 NFRC 0.32 1 NFRC 270 New IWC 5300 Vinyl/Low-E 1st Floor Zone 18 Window 8.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 Vinyl/Low-E 1st Floor Zone 19 Window 40.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vin l/Low-E 1st Floor Zone 20 Window 25.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vinyl/Low-E 1st Floor Zone 21 Window 8.0 0.370 NFRC 0.32 NFRC 90 New I IWC 5300 Vinyl/Low-E 1 st Floor Zone 22 Window 8.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vinyl/Low-E 1 st Floor Zone 23 Skylight 8.0 0.370 NFRC 0.29 NFRC 0 New Velux (4X2) 1st Floor Zone 24 Skylight 2.5 0.550 Default 0.67 Default 0 New Double Non Metal Clear 1st Floor Zone (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 None 1.00 24 None 1.00 Ener Pro 5.1 bi Ener Soft User Number: 4970 RunCode: 2013-02-06709:07:59 ID: RC120944 Page 6 of 12 CCRTIMCA E OF C OIMIPUANC E. ResWeMW (Part 5 of 5) CSF -1 R Project Name Mr. Chang's Redisence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/6/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 st Floor 1,878 18,760 Totals 1 1,878 0 0 0 HVAC SYSTEMS System Name Qty. Heating T pe Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Basement 6.0 ❑ New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RHEEM 44V50 1 Small Gas No Pipe Insulation 40,000 50 0.61 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control 7Qty.HP Hot Water Piping Length ft 0 m a (n — System Name Pipe Length Pipe Diameter Insul. Thick. Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number. 4970 RunCode: 20 1 3-02-0 6 70 9:07:59 ID: RC 120944 Pae 7 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Mr. Chang's Redisence Date 2/6/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Envelope Measures: =Building 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. .§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent LI -factor. _*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fire laces, Decorative Gas Appliances and Gas'Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. -Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and -spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of -recirculating sections of hot water pipes are insulated per Standards Table 150-13. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-02-06T09:07:59 ID: RC120944 Page 8 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. Chang's Redisence 2/6/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 1816 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation in Section 4 of that Standard. -required Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or _programmed to run only during off-peak electric demand periods. 150 : Residential pool systems ore ui ment meet the purne sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. The wattage of permanently installed luminaires shall be determined asspecified by §130(d). -§150(k)3: §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). All switching devices and controls shall meet the requirements of §150(k)7. -§150(k)7: §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-02.06709:07:59 ID: RC120944 Page 9 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr. Chang's Redisence 2/6/2013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable -requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-02-06709:07:59 ID: RC120944 Page 10 of 12 HVAC SYSTC (M HEATING TDD C OOLIING LADS SUMMARY Project Name Mr. Chang's Redisence Date 2/6/2013 System Name HVAC Floor Area 1,878 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 569 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK System Sensible Latent CFM Sensible -Heating Output per System 94,000 12,187 307 483 23,076 Total Output Btuh 94,000 0 Output Btuh/s ft 50.1 176 1,002 Cooling System 0 0 Output per System 46,300 0 0 0 0 Total Output Btuh 46,300 0 307 0 Total Output Tons 3.9 176 1,002 Total Output Btuhis ft 24.7 Total Output s ftfTon 486.7 1 12,539 1 25,080 Air System CFM per System 1,375 HVAC EQUIPMENT SELECTION Airflow cfm 1,375 Carrier 58MTB100-20 CNP 38HD 4 T 41,255 2,470 94,000 Airflow cfmis ft 0.73 Airflow cfmlTon) 356.4 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 41,255 F 2,470 94,000 Aug 3 PM Jan 1 AM Outside Air cfmis ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 28 IF 69 OF Ou7Air GfmSupply Fan 1,375 cfm 69 IF 69 IF 115 IF Heating Coil 1141F ROOM 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 88 168 OF 75161 IF 75161 IF 55154 IF Outside Air ` 0 cfm Supply Fan Cooling Coil 1,375 cfm 75 / 61 IF ff 55 154 IF 45.6% I®d1' '1' 75161 IF EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-02-06T09:07:59 ID: RC120944 Page 11 of 12 ENERGY USE AND COST SUMMARY ECON-1 Project Name Mr. Chang's Redisence Date 2/6/2013 Rate: Electric Alameda H Fuel Type: Electricity STANDARD PROPOSED MARGIN Energy Use (kWh) Peak Demand kW Cost $ Energy Use kWh Peak Demand (kW) Cost $) Energy Use (kWh) Peak Demand Cost kW) ($ Jan 101 1 15 86 1 14 15 0 2 Feb 67 2 12 57 2 11 10 0 1 Mar 54 2 11 46 2 10 7 0 1 Apr 65 3 12 52 2 10 13 1 1 May 32 4 8 22 3 7 10 1 1 Jun 108 5 16 71 4 12 37 1 4 Jul 141 4 20 104 3 16 37 1 4 Aug170 5 22 128 4 18 42 1 4 Sep 99 6 15 73 4 12 26 1 3 Oct 43 4 9 36 3 9 7 1 1 Nov 62 1 11 52 1 10 10 0 1 Dec 99 1 15 84 1 14 15 0 2 Year 1,042 6 167 811 4 143 230 1 24 CO2 839 lbs/yr 653 1 lbs/yr 1851 lbs/yr Rate: Gas PG&E P Fuel T e: Natural Gas STANDARD Energy Peak Use Demand therms kBtu/hr) Cost $ Energy Use therms PROPOSED Peak Demand kBtu/hr Cost ($) Energy Use therms) MARGIN Peak Demand Cost (kBtu/hr) $ Jan 92 62 121 70 50 90 22 12 32 Feb 63 54 78 49 45 61 13 9 17 Mar 53 51 66 43 43 54 10 9 12 Apr 45 44 56 38 37 47 7 7 9 May 23 37 30 22 31 28 1 6 2 Jun 20 29 26 19 25 25 1 4 1 Jul 20 5 26 19 5 25 1 0 1 Aug20 5 26 19 5 25 1 0 1 Sep 19 5 25 19 5 24 1 0 1 1 Oct 24 40 32 22 33 29 2 7 3 Nov 62 56 77 48 46 60 14 10 17 Dec 90 64 119 69 51 87 21 12 31 Year 532 64 684 439 51 556 93 12 128 CO21 6,225 lbs/yr 5,133 Ibs/ r 1,092 lbs/yr Annual Totals Energy Demand Cost Cost/s ft Virtual Rate Electricity 811 kWh 4 kW $ 143 $ 0.08 /s ft $ 0.18 /kWh Natural Gas 439 therms 51 kBtu/hr $ 556 $ 0.30 is ft $ 1.27 /therm Total $ 700 $ 0.37 /s ft Avoided CO2 Emissions: 1,278 lbs/yr EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-02.06T09:07:5 ID: RC120944 Page 12 of 12 r e Project Flame: Project Address: Project Description: CALGREEN SIGNATURE DECLARATIONS y el e- 'IZ7 er- A. L SECTION I - DESIGN VERIFICATION Complete all lines of Section 1 —"Design Verification' and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated Into the project plans and will be implemented into the project In accordance with the requirements set forth in the 2010 California Green Building Standards Code as adopted by the City of Cupertino. Q��� Wf 3 Owner's Signa f ,� to Rao H (2 C aq Owners Name (Please R ' t 3 Design Professional' nature Date AROK Design Profe ' nal' _nn Signature of License sional m4onsible for CalGreen compliance Date Name of License Professional responsible for CaIG een compliance (Please Print) Phone 13= ,C Email Address for License Professional responsible for CalGreen compliance SECTION 2 m IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, Including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2010 California Grgen Buildinc Standards Code as adopted by the City of Cupertino. Signature of License PrW§ionallresponsible forCallGrew complianceDate Z�WE54& `Sl�V (""\ ptTYJ Name of License Profes/ssiional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 5 of 5 CalGreen 2010.doc revised 0&/27/11 CUPERTINO OWNER -BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT ^ BUILDING DIVISION 10300 TORRE AVENUE " CUPERTINO, CA 95014-3255 (408) 777-3228 " FAX (408) 777-3333 • buildinala cupertino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESSET L APN BP# oZ OWNER AME A OWNER ADDRESS DESCRIPTION OF.WORK: We. are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware'of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner Bu der" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 5 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 3. 1 understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that.I may rotect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her �/naame instead of my own. f� 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. A45. [understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered. an "employer" under state and federal law. 6. 1 understand'if I am considered an "employer" under state and federal law, I must register with the state and Federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. &�._7. 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 4_�_8. 1 understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForm 2010.doc revised 04/14/10 9. 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal enue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 1�10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. V�11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. k12: 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the.. iformation. I. have provided on .this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS: Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.). Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owners driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verifv the property owners signature. Property Owner's Signature:dG,�.G%_ Date: PI -l" 7-// ---------------------------------------------------------------------------------------------------------------------------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder). AUTHORIZATION OF AGENT TO ACTON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby. authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Tel No Address of Authorized Agent: I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the . above information and certify its accuracy. Note: A copy of the property owners driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: OwnerBuilderForn: 2010.doc revised 04114110 C UPERTINO 2010 CALGREEN RESIDENTIAL CHECKLIST - MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DiviOFFICE COPY ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE ^ CUPERTINO, CA 95014-3255 „ n (408) 777-3228 • FAX (408) 777-3333 o buildincOlcupertino.ora PLIRPOSE: d�� Ajj The 2010 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwee'' dormitories, condominiums, shelters, congregate residences, employee housing, factory -built housing and other types of swellings with sleeping accommodations and new accessory buildings associated with such uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: Project Address: Project Description: /ALJ /tee- /. S1- B sem- a dz !k -3 7 s-. Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the 2010 California Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - D ea-ification ai �e6liecklist and have the checklist printed on the approved plans for the Duildin D 3. Prior to final inspection by the Building Depart = icensed profess na VVI Rkplete Column 3 and sign and date Section 2 - Implementatio Itlo%% h? 9n��p�this checklist and submit the completed form to the Building Inspector. t�� REVIEWED FOR COPE COMPLIANCE Calla Column 3 MANDATORY FEATURE OR MEASURE Project Verification Re uirements ., .1 PLANNING AND DESIGN y � F O £ ' •''' xs i `� k gz. ,, 6 �6n ., 'ip r S iW". J F k m r�i 4.104.1 A site plan and inventory of the site is developed and used to minimize site disturbance in order preserve desirable existing natural resources and ❑X minimize future adverse effects on the proposed structure. r ,y't •:t it "E J :MM,' -..A, I'�x eG�f}'f�„i 4 j7 s 1119IM111E %02�%Rli1 � ♦ ar� Ma+rW4 ��KM' er' Er IS ”! IF7`1f Z „£yzry'.,H, $mnWW Pj-RI '' R'v1 ��1,. .3I, 1 N' i w4& ' +XYS §'S'16� •.F 4.106.2 A plan is developed and implemented to manage storm water drainage during construction. 4.106.3 The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. AAAD I�... Page I of 5 CdlCreer�HZQ�0.�Lac revised 08127111 Page 2 of 5 CalGreen_2010.doc revised 08/27/11 1,. ' �? :','.'§%n "sTYS' '§��; iK ,i;v<t i ,f. � 4dwx, gt ;� .d , ,,,H:•gq ., �,... �, �ii 2,., v.`r�3 a�, ", .. 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. Bn�oop Vl E' .e ...,.. 4.,... �a �. � . ��� 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the follow methods. ® Water saving fixtures or flow restrictors shall be used per Table 4.303.2. As of 7/01!2011 ® A 20 percent reduction in baseline water use shall be demonstrated per Table 4.303.1. 4.303.2 When using the calculation method specified in Section 4.303.1, multiple showerheads shall not exceed maximum flow rates. El As of 7/01/2011 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with specified performance requirements. El As of 7/01/2011 }, $�P �ffi�E�➢ app �6�N�IM , 6.. ",_11,.T e9sws 'kv'�? 4.304.1 Automatic irrigation systems installed at the time of final inspection shall be weather -based. e e e e 011\JC�J�IJ�S V' (rJ U LIIuJU�J�° Lftl D a 0 �— pp'.p+r,�"", x{ai.�FMpw a�}I,�Fy1 b. p�Q' d I Ura ,�{r i '�i��lP�4J �W��PR�OIQI dI tl10YW�tl`L' m14� M & N !' ) Sr,. ''111 ,. 4.406.1 Joints and openings. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected El against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. u.p` � 1l 6Me,-Re ��c�clim O� ra�c$��an r �� r�ar.'R 4.408.2 Where a local jurisdiction does not have a construction and demolition waste management ordinance, a construction waste management plan shall be submitted for approval to the enforcing agency. M' ffi$e�ifi ar�d �,f 911 �,..".�10 4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner. Page 2 of 5 CalGreen_2010.doc revised 08/27/11 Page 3 of 5 CnlGreen_2010.doc revised 08/27/!! 4.503.9 Install only a direct-vent sealed-combustion gas or sealed wood- ❑ ❑ burning fireplace, or a sealed woodstove. x'` t'v i' k s�� .. y "`hti.,. �1��NOW �V��$P w/7/i�/g,yr/v�s"iRaw. 4.504.9 Duct openings and other related air distribution component openings ❑ shall be covered during construction. 4.504.2.9 Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits. ❑X 4.504.2.3 Aerosol paints and other coatings shall be compliant with product ❑X ❑ weighted MIR Limits for ROC and other toxic compounds. 4.504.2.4 Documentation shall be provided to verify that compliant VOC limit ❑ finish materials have been used. 4.504.3 Carpet and carpet systems shall be compliant with VOC limits. ❑X 4.504.4 Fifty (50) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance El (CHPS) Low-emitting Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall comply with low formaldehyde ❑ emission standards. vsuiE 3 .�a ' ps„q $ `v a "Interior IVloisture Control �� k nkk r3°Y 4.r u,G •S''* .kg r> ,i.,, . Pu, 'Y.* r: x,i , %h"� ✓4 r#•, 'st'k'•. 4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. ❑X ❑ 4.505.3 Moisture content of building materials used in wall and floor framing is El before enclosure. Page 3 of 5 CnlGreen_2010.doc revised 08/27/!! Y"'s �•: ' ,� t.: Val w,a 9ndoor Air Qtalityand Exhaust-� �4WN� 4.506.1 Exhaust fans which terminate outside the building are provided in ® ❑ every bathroom. ," y4 1'w�l'gg E Comfort $ 1VIT06mental , 4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the fan is off. Covers or louvers shall have a minimum ® ❑ insulation value of R-4.2. 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS R, 702.1 HVAC system installers are trained and certified in the proper installation ® ❑ of HVAC systems. 702.2 The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the discipline they inspect ❑X ❑ and verify. X rc Verifia04'0 dg b.„P"` . ...Y9h,.v,i1-�' 703.9 Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which show ❑ substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen_2010.doc revised 08/27/11