Loading...
14040203I CITY OF CUPERTINO BUILDING PERMIT I BUILDING ADDRESS: 1105 MILKY WAY I CONTRACTOR: SOD BUILDERS I PERMIT NO: 14040203 1 I OWNER'S NAME: VAN ZOEREN HAROLD R AND JANET 1 397 BAY ST I DATE ISSUED: 06/10/2014 1 OWNER'S PHONE: 4084461701 1 SAN JOSE, CA 95123 1 PHONE NO: (8 18) 343 -3520 ❑ LICENSED CONTRACTOR'S DECLARATION License Class 6 Lie. #J �/U K Contractor. 0,0 Rik 1 /gam Date b �v I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: 1 have and will maintain a certificate of consent to self- insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature _ /�// (/ _Date ❑ OWNER- BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate ofexemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL CONSTRUCT ONE STORY ADDITION (262 SQ FT). Sq. Ft Floor Area: APN Number: 36219010.00 PERMIT E Valuation: $40000 Occupancy Type: IS NOT STARTED WITHIN 18 DAYS OF PERMIT ISSUANCE OR 180 DAY M LA,S� CALLED INSPECTION. Issued by: Date: RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(x) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 5534. Owner or authorized agent: v Date: -/ /,g CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Ad ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • building(a)cupertino.org CUPERTINO ❑ NEW CONSTRUCTION ek ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT I PROJECT ADDRESS ! I 1, APN # 1 2 `q — 0/o ` I OWNERNAME PHONE y ,+) i ' 1 , y. - i E -MArL STREET ADDRESS I I I I CITY, STATE, ZIP FAX 0 U/ w t, ,�0 R .;ar CONTACT NAME ^ n O PHONE _ 73 _ E-MAILl�� ` y7 3�o STREET ADDRESS CITY, STATE, ZIP FAX �l x-25 C- ❑ OWNER ❑ OWNER- BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME O I C LICENSE NUMBER I ��Q C � LICENSE TYPE jQ� Jm BUS. LIC # � A0, C1 COMPANY NAME ® I i7- � � �_ E-MAIL In FAX /1 , IST � � _77 7_� STREET ADDRESS CITY, STATE, ZIP PHO /y— J'/3-� SO ARCHITECT/ENGrNEER NAME LICENSENUMBER BUS, LIC COMPANY NAME E -MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK — EXISTING USE PROPOSED USE CONSTR TYPE # STORIES USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG AREA NEW FLOOR AREA 2—C ;?� DEMO AREA TOTAL NET AREA ,. YI y Zic Z BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH # DWBLLrNG UNITS: IS A SECOND UNIT []YES SECOND STORY ❑YES BEINGADDED? R ADDITION? 251'NO PRE - APPLICATION ❑YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEIVED BY TQ %AL VALUATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? jSa-NO t y j �wor /EDJ By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property ommer's behalf. I have read this application and the information I have provided is correct. I have read the Desc ' verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construe Ives o upertino to enter the above -i entifie roperty for inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTAL rNTFORMATION REQUIRED ra�icaECxPE z, xovTUNG_s%iP New SFD or Multifamily dwellings: Apply for demolition permit for ❑N ovEii THE cotmTEx .h Sk.wnr ❑ J3inLnrrGrs aIRE�IEW 4 existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑„ aPxESS � r i�P-n pi,An�.>rGPL�,NREVIEw Commercial Bldgs: Provide a completed Hazardous Materials Disclosure �1NDARD >'uB1ICWORr{sa c _ form if any Hazardous Materials are being used as part of this project. ❑ NNW rte} ❑ LARGE � ,� ,,,� � FIRE DEP'Jy::� �'+* �r N y w., ��> sg _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑' IitiiroR ra # '� ❑ SAI�ITARYSE RDISTRICT submittal of Building Permit application. k' ❑;'E1���IRONTIENTA'I,HEALTFi ^r , b� f. . � . __I� . BldgApp_2011.doc revised 06121111 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION IVAADDRESS: 1105 MILKY WAY TYPE OF CONSTR. DATE: 04/30/2014 REVIEWED BY: MELISSA APN: 362 19 010 BP #: Z Q 'VALUATION: 1$40,000 "PERMIT TYPE: Building Permit $1,579.00 PLAN CHECK TYPE: Addition lADDINSP PRIMARY SFD or Duplex USE: PME Plan Check: 2nd Unit? 0 Yes � No [OTC? 0 Yes G No PENTAMATION PERMIT TYPE: 1 R3SFDADD WORK ADDITION OF 262 S.F. TO CREATE N FAMILY ROOM Permit Fee: $1,284.00 SCOPE 0 OT T 0,0 hrs $0.00 OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R -3 (Custom) II- B,111- B,IV,V -B 262 $1,579.00 IADDPLCK $1,284.00 lADDINSP $0.00 PME Plan Check: $0.00 Permit Fee: $1,284.00 Suppl. Insp. Fee:Q Reg. 0 OT T 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: TOTALS: 262 $1,579.00 $1,284.00 MECH, HOURLY 0 Yes D No PLUMB, HOURLY 0 Yes Q No ELEC, HOURLY Q Yes Q No E3_L__ F-1 Li _L_ NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (1-,ee Resolution 11 -053 Eft: 711%731 FEE QTY /FEE MISC ITEMS Plan Check Fee: $1,579.00 Select a Misc Bldg /Structure or Element of a Building Suppl. PC Fee: E) Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $1,284.00 Suppl. Insp. Fee:Q Reg. 0 OT T 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 G Work Without Permit? 0 Yes (j) No $0.00 Advanced Plannin-T Fee: 1PLLONGR $36.68 Select a Non - Residential Building or Structure 0 Strom Motion Fee. IBSEISMICR $4.00 Select an Administrative Item Bld& Stds Commission Fee: IBCBSC $2.00 SUBTOTALS: $2,905.68 $0.00 TOTAL FEE: $2,905.68 Revised: 04/01/2014 Building Department City Of Cupertino 10300 Torre A,venve Cupertino, CA 9501.4 -3255 Telephone: 408 - 777 -3223 C U P E RT I N O Fax: 408 - 777 -3333 CONTRACTOR / SUBCONTRACTOR LIST JOBA.DDRESS �1>,QS rnilK. % ' kmo 95014 �OWNEWSNAME: PERMIT .# -- H090ZO.� - _ _ -- _ - Kay-m.- -_gfy, Zoerty -N __.. P14O —NE# 800- 1-101 2i✓O Cabinets & MiIiworlc C r.NERAL CONTRACTOR: $o0 u: \GIa�S BUSINESS LICENSE* _ .ADDRESS: 113-3-7 Na ��.b; -t}:j OL__ -,..� (w �tG14 CZ'I'y /ZIPCOD _ *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO'BVIIA)I:NG FINAL OIL. FINAL OCCUPANCY INSPECTION(S) WILL BE SCI•I'EDULED UNTIL THE GENERAL CONTRACTOR 01) ALL SU RACTORS HAVE OBTAINED A CITY Or CUPERTINO BUSINESS.LICENSE. 1 am not using any subcontractors: ..., -._ _.___._._...._._. .._..,...,......_._�,._-- . -__ -- ..._....._---- ___,.._.._,.. -- Signature Date Please check applicable subcontractors and complete the following information: Owner I Contractor Signature pate Z0 /Z0 39-Vd Sa3G-Iina aos ZGTGMRRR RA:9T CTA7 /7A /TA SUBCONTRACTOR BUSINESS NAME — —� BUSINESS LICENSE # Cabinets & MiIiworlc Cement H aishing _— Electrical.' r ...� Excavation��- _._____._ Flooring / Carpeting Linoleum / Wood _ Glass / GIazi.ng _.._..._....._._ Heating __..____..._...,. _._....__.,.---..... ...... __.._._ -- Insulation . - - - - -- ,Landscaping -- - -__�. Lathing Masonry � ----------- - --- -- -- ._._ --._ - Painting / Wallpaper _. — Paving Plastering Roofing �— Septic "Tank - - -- Sheet Metal Sheet Rock Tile Owner I Contractor Signature pate Z0 /Z0 39-Vd Sa3G-Iina aos ZGTGMRRR RA:9T CTA7 /7A /TA CUPERTINO CONTRACTOR / SUBCONTRACTOR LIST Building Department Ciry Of Cupeatino 10300 Torre Avenue Cupertino, CA 95014 -3255 Telephone: 408- 777 -3228 Fax: 408-777-3333 JoB wDRZ SS: 11� rn;tK. 95o►y 1'l::ItMITtf __ _C���,! OWNER'S NA -yt1r: Ka�'�'? . -Iran Zoer -cam ---- ,.r..- - -- ..,,0 - - _I'1�i0?�I�, #_900- Dior -- GENERA.(, CON7'IZAC�'r017 rjo� S3o;�cl�s BUSINESS LICENSE t1 _ _ADDRESS: V1 11 33- �,,; -� �n� Es,,.,r� cri 9 j3)t CI'TY1,z1PCOD_r.__._._..°1 so►!� -- -- -- - - - -- *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO 'BUILDING FINAL OR. FINAL OCCUPANCY INSPECTIONS) WILL I3'E SCHEDULED UNTIL THE GI NUTAL CONTRACTOR AND ALL SIJ RACI'ORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS L.IC.CNS:E. I ani not using any subcontractors: ,. - 2 i Signature Date Please check applicable subcontractors and complete the following information: e/ SUBCONTRACTOR BUSINESS NAME — — BUSINESS LICENSE # Cabinets & Millwork Cement Finishing E.lcctrical. -�� _ Excavation Fencing _...,___....___.. —.._ Flowing / Crarpet%ng.� Linoleum / Wood - - -~�. ___._._.,.•__,,,�_ Glass / Glazing Heating Insulaticm Landscaping Lathing Masonry Painting /Wallpaper Paving Plastering Plumbing __..._. Roofing . ._._. .Septic Tavl<.-- .,._��'_ Sheet Metal Sheet Rock Tile Owner / Contractor Signature —� — Date TO/TO 39Cd S83G -Ung QOS ZGTGLLL888 TO:9T 9T07/7R /TR I CUPERTIN© WATER- CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777- 3228• FAX (408) 777 -3333 - buildingncupertino.org Owner Name .�;SL,,Qft Permit No. 1 110 Address i C �' i ki} \i_ , L(4 — I PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION Please refer to the attached California Civil Code Sections 1101.1 — 1101.8 which are part of this Certification form. I. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: No Go to Question 2. Date: 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water- conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. Owner' Signature: >0 No Go to Question 3. Date: 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1 101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: No Go to Question 4. Date: 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date: Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1 101.8 apply. Refer to the attached. My property is a single- lminih• residential real property. See Civil Code Section 1 101.4. On and after January I, 2014, building alterations or improvements shall require all non - compliant plumbing fixtures to be replaced with water- conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non - compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a nniltiknrihv residential real property. See Civil Code Section 1 101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant Plumbing fixtures to be replaced with water - conserving plumbing fixtures. On or before January 1, 2019, all non - compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improve men is ). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January I, 2014. specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water- conserving plumbing fixtures. S8407 2014.doe reused 03,118114 On or before January 1, 2019, all non- compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). UWe, the owner(s) of this property, certify under penalty of perjury that non - compliant plumbing fixtures have been replaced with water - conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 110 1.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water- conserving plumbing fixtures comply with the requirements as indicated in the table below. Owner's (or Owner Agent's) Signature: �d ,�„_ )�\ \,� - .-Z, Date: Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit. 1. If the existing plumbing fixture water usage /flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2014.doc revised 03 118114 Non - Compliant Water- Conserving Plumbing Fixture Plumbing Fixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single - Family Multi- Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons /flush (Toilets) Gallons /flush Dual flush toilets: 1.28 gallons /flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons /flush Gallons /flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand -held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and /or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow onl one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute (w 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute C) 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage /flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2014.doc revised 03 118114 CALIFORNIA CIVIL CODE SECTIONS 1101.1- 1101.8 Civil Code Division 2. Property Part 4. Acquisition of Property Title 4. Transfer Chapter 2. Transfer of Real Property Article 1.4. Installation of Water Use Efficiency Improvements ........ 1101.1 — 1101.8 1101.1. The Legislature finds and declares all of the following: (a) Adequate water supply reliability for all uses is essential to the future economic and environmental health of California. (b) Environmentally sound strategies to meet future water supply and wastewater treatment needs are key to protecting and restoring aquatic resources in California. (c) There is a pressing need to address water supply reliability issues raised by growing urban areas. (d) Economic analysis by urban water agencies has identified urban water conservation as a cost - effective approach to addressing water supply needs. (e) There are many water conservation practices that produce significant energy and other resource savings that should be encouraged as a matter of state policy. (f) Since the 1991 signing of the "Memorandum of Understanding Regarding Urban Water Conservation in California," many urban water and wastewater treatment agencies have gained valuable experience that can be applied to produce significant statewide savings of water, energy, and associated infrastructure costs. This experience indicates a need to regularly revise and update water conservation methodologies and practices. (g) To address these concerns, it is the intent of the Legislature to require that residential and commercial real property built and available for use or occupancy on or before January 1, 1994, be equipped with water - conserving plumbing fixtures. (h) it is further the intent of the Legislature that retail water suppliers are encouraged to provide incentives, financing mechanisms, and funding to assist property owners with these retrofit obligations. 1 101.2. Except as provided in Section 1101.7, this article shall apply to residential and commercial real property built and available for use on or before January 1, 1994. 1 101.3. For the purposes of this article: (a) "Commercial real property" means any real property that is improved with, or consisting of, a building that is intended for commercial use, including hotels and motels, that is not a single - family residential real property or a multifamily residential real property. (b) "Multifamily residential real property" means any real property that is improved with, or consisting of, a building containing more than one unit that is intended for human habitation, or any mixed residential - commercial buildings or portions thereof that are intended for human habitation. Multifamily residential real property includes residential hotels but does not include hotels and motels that are not residential hotels. (c) "Noncompliant plumbing fixture" means any of the following: (l ) Any toilet manufactured to use more than 1.6 gallons of water per flush. (2) Any urinal manufactured to use more than one gallon of water per flush. (3) Any showcrliead manufactured to have a flow capacity of more than 2.5 gallons of water per minute. (4) Any interior faucet that emits more than 2.2 gallons of water per minute. (d) "Single- family residential real property" means any real property that is improved with, or consisting of, a building containing not more than one unit that is intended for human habitation. (e) "Water- conserving plumbing fixture" means any fixture that is in compliance with current building standards applicable to a newly constructed real property of the same type. (f) "Sale or transfer" means the sale or transfer of an entire real property estate or the fee interest in that real property estate and does not include the sale or transfer of a partial interest, including a leasehold. 1101.4. (a) On and after Jamrary 1, 2014, for all building alterations or improvements to single - family residential real property, as a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department, the permit applicant shall replace all noncompliant plumbing fixtures with water - conserving plumbing fixtures. (b) On or before January 1, 2017, noncompliant plumbing fixtures in any single- family residential real property shall be replaced by the property owner with water - conserving plumbing fixtures. (c) On and after January 1, 2017, a seller or transferor of single - family residential real property shall disclose in writing to the prospective purchaser or transferee the requirements of subdivision (b) and whether the real property includes any noncompliant plumbing fixtures. 1 101.5. (a) On or before January 1, 2019, all noncompliant plumbing fixtures in any multifamily residential real property and in any commercial real property shall be replaced with water - conserving plumbing fixtures. (b) An owner or the owner's agent may enter the owner's property for the purpose of installing, repairing, testing, and maintaining water- conserving plumbing fixtures required by this section, consistent with notice requirements of Section 1954. (c) On and after.lanuary 1, 2019, the water - conserving plumbing fixtures required by this section shall be operating at the manufacturer's rated water consumption at the time that the tenant takes possession. A tenant shall be responsible for notifying the owner or owner's agent if the tenant becomes aware that a water- conserving plumbing fixture within his or her unit is not operating at the manufacturer's rated water consumption. The owner or owner's agent shall correct an inoperability in a water- conserving plumbing fixture upon notice by the tenant or if detected by the owner or the owner's agent. (d) (1) On and after January 1, 2014, all noncompliant plumbing fixtures in any multifamily residential real property and any commercial real property shall be replaced with water - conserving plumbing fixtures in the following circumstances: (A) For building additions in which the sum of concurrent building permits by the same permit applicant would increase the floor area of the space in a building by more than 10 percent, the building pen-nit applicant shall replace all noncompliant plumbing fixtures in the building. (B) For building alterations or improvements in which the total construction cost estimated in the building permit is greater than one hundred fifty thousand dollars ($150,000), the building permit applicant shall replace all noncompliant plumbing fixtures that service the specific area of the improvement. (C) Notwithstanding subparagraph (A) or (B), for any alterations or improvements to a room in a building that require a building permit and that room contains any noncompliant plumbing fixtures, the building permit applicant shall replace all noncompliant plumbing fixtures in that room. (2) Replacement of all noncompliant plumbing fixtures with water - conserving plumbing fixtures, as described in paragraph (1), shall be a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department. (e) On and after.lanuary 1, 2019, a seller or transferor of multifamily residential real property or of commercial real property shall disclose to the prospective purchaser or transferee, in writing, the requirements of subdivision (a) and whether the property includes any noncompliant plumbing fixtures. This disclosure may be included in other transactional documents. 1 l 01.6. The duty of an owner or building permit applicant to comply with the requirements of this article shall be postponed for one year from the date of issuance of a demolition permit for the building. If the building is demolished within the one -year postponement, the requirements of this article shall not apply. If the building is not demolished after the expiration of one year, the provisions of this article shall apply, subject to appeal to the local building department, even though the demolition permit is still in effect or a new demolition permit has been issued. 1101.7. This article shall not apply to any of the following: (a) Registered historical sites. (b) Real property for which a licensed plumber certifies that, due to the age or configuration of the property or its plumbing, installation of water - conserving plumbing fixtures is not technically feasible. (c) A building for which water service is permanently disconnected. 1101.8. A city, county, or city and county, or a retail water supplier may do either of the following: (a) Enact local ordinances or establish policies that promote compliance with this article. (b) Enact local ordinances or establish policies that will result in a greater amount of water savings than those provided for in this article. Owner N Address WATER-CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRF AVENUE - CLJPFRTINO CA grn14- 32.ri.r, Please refer to the attached California Civil Code Sections 1101.1 — 1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: ❑ No Go to Question 2. Date: 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water - conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. Owner' Signature: ❑ No Go to Question 3. Date: 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: ❑ No Go to Question 4. FIL 4. Is your real property built and available for use or occupancy on or before January /ate: ffoof ❑ No My real property is built and available for use or occupancy after Janua 994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the form. Owner' Signature: Date : My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. �rMy property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non- compliant plumbing fixtures to be replaced with water - conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non - compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 20I4, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water - conserving plumbing fixtures. On or before January 1, 2019, all non - compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water - conserving plumbing fixtures. SB4071014. doc revised 0112811-4 On or before January 1, 2019, all non - compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non - compliant plumbing fixtures have been replaced with water - conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water - conserving plumbing fixtures comply with the requirements as indicated in the table below. Property Owner's Signature: A•. Date: :11-L Y l� Upon completing and signing this Certificate, please return it,to the Building Division in order to final your permit. 1. If the existing plumbing fixture water usage /flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4071014. doc revised 01128114 Non - Compliant Water- Conserving Plumbing Fixture Plumbing Fixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single - Family Multi - Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons /flush (Toilets) Gallons /flush Dual flush toilets: 1.28 gallons /flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons /flush Gallons /flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand -held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and /or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage /flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4071014. doc revised 01128114 g4' F C: BUILDING ENERGY ANALYSIS REPORT PROJECT: i /A'f «y / ?A0gADDITIbN 1105 Milky Way Cupertino, CA 95014 Project Designer: AZZURRA DESIGN GROUP INC. 5337 Coldwater Canyon Avenue # D Sherman Oaks, California 91401 818 - 402 -3906 Report Prepared by: APR 302014 ICY FERMIN AGOSTO 1st & 2nd Generation Energy Consultants 7441 Hazeltine Avenue # 108 Van Nuys, CA. 91405 (818) 626 -0061 Job Number: 2014 -4 -22 Date: 4/22/2014 ,Y The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014 -04- 22707:21:43 0: 2014 -4 -22 1 k � x I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 15 EnergyPro 5.1 by EnergySoft Job Number: ID: 2014 -4 -22 User Number: 2579 PERFORMANCE CERTIFICATE: Residential Part 1 of 5) CF -1 R Project Name ENCLOSED PATIO ADDITION Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition /Alteration Date 412212014 Project Address 1105 Milky Way Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 1,864 Addition 262 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST • Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. • Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Wall Wood Framed None 1,143 Existing Door Opaque Door None 40 Existing Slab Unheated Slab -on -Grade None 1,602 Perim = 203' Existing Roof Wood Framed Attic R -11 1,602 Existing Wall Wood Framed R -13 129 New Slab Unheated Slab -on -Grade None 262 Perim = 32' New Roof Wood Framed Attic R -30 262 New FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (E) 52.0 0.550 0.67 none none Bug Screen Existing Left (S) 66.0 0.550 0.67 none none Bug Screen Existing Rear (W) 64.0 0.550 0.67 none none Bug Screen Existing Rear (W) 50.6 0.550 0.67 none none Bug Screen Removed Right (N) 7.7 0.710 0.73 none none Bug Screen Removed Rear (W) 70.0 0.370 0.32 none none Bug Screen New Right (N) 60.0 0.370 0.32 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 75% AFUE Split Air Conditioner 8.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status (E) HVAC Split System Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014- 04- 22T07:21 :43 ID: 2014 -4 -22 Pa e 3 of 16 0 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name ENCLOSED PATIO ADDITION Building Type ® Single Family ❑ Addition Alone ❑ Multi Family 2 Existing+ Addition /Alteration Date 412212014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and /or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnerqyPro 5.1 by EnerqySoft User Number: 2579 RunCode: 2014 -04- 22 70 7:21:43 ID: 2014 -4 -22 Pa e 4 of 16 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date ENCLOSED PATIO ADDITION ❑ Multi Family m Existing+ Addition /Alteration 412212014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu /ft2- r Space Heating 46.73 45.82 0.91 Space Cooling 35.74 30.76 4.99 Fans 10.89 10.04 0.85 Domestic Hot Water 19.50 19.50 0.00 Pumps 0.00 0.00 0.00 Totals 112.86 106.12 6.74 Percent Better Than Standard: 6.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls /Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 374 52 Fuel Available at Site: Natural Gas (S) 438 66 Raised Floor Area: 0 (w) 375 134 Slab on Grade Area: 1,864 (N) 438 60 Average Ceiling Height: 8.0 Roof 1,864 0 Fenestration Average U- Factor: 0.48 TOTAL: 312 Average SHGC: 0.52 Fenestration /CFA Ratio: 16.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company 1 st & 2nd Generation Energy Consultants 4/ 2/2014 Address 7441 Hazeltine Avenue # 108 Name FERMIN AGOSTO City /State /Zip Van Nuys, CA. 91405 Phone (818) 626 -0061 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company AZZURRA DESIGN GROUP INC. Address 5337 Coldwater Canyon Avenue # D Name Eyal Abraham City /State /Zip Sherman Oaks, California 91401 Phone 818 - 402 -3906 Signed License # Date EnerqvPro 5.1 by EnerqySoft User Number- 2579 RunCode: 2014 -04- 22707:21:43 ID. 2014 -4 -22 Page 5 of 16 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name ENCLOSED PATIO ADDITION Building Type IZI Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition /Alteration Date 412212014 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location /Comments Cavity Exterior Frame Interior Frame Wall 302 0.356 None 90 90 Existing 4.3.1 -A1 First Floor Door 20 0.500 None 90 90 Existing 4.5.1 -A4 First Floor Wall 372 0.356 None 180 90 Existin 4.3.1 -A1 First Floor Wall 179 0.356 None 270 90 Existing 4.3.1 -A1 First Floor Wall 81 0.356 None 270 90 Removec 4.3.1 -A1 First Floor Wall 290 0.356 None 0 90 Existing 4.3.1 -A1 First Floor Door 20 0.500 None 0 90 Existin 4.5.1 -A4 First Floor Wall 120 0.356 None 0 90 Removeo 4.3.1 -A1 First Floor Slab 1,602 0.730 None 0 180 Existin 4.4.7 -A1 First Floor Roof 1,602 0.079 R -11 0 0 Existing 4.2.1 -A2 First Floor Wall 61 0.102 R -13 270 90 New 4.3.1 -A3 First Floor Wall 68 0.102 R -13 0 90 New 4.3.1 -A3 First Floor Slab 262 0.730 None 0 180 New 4.4.7 -A1 First Floor Roof 2621 0.031 R -30 0 0 New 4.2.1 -A20 First Floor FENESTRATION SURFACE DETAILS ID Type Area U- Factor SHGC Azm Status Glazing Type Location /Comments 1 Window 40.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear First Floor 2 Window 12.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear First Floor 3 Window 66.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear First Floor 4 Window 64.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear First Floor 5 Window 50.6 0.550 Default 0.67 Default 270 Removed Double Non Metal Clear First Floor 6 Window 7.7 0.710 Default 0.73 Default 0 Removed Glass Block First Floor 7 Window 30.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 Vinyl /Low -E First Floor 8 Window 40.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 Vinyl /Low -E First Floor 9 Window 60.0 0.370 NFRC 0.32 NFRC 0 New IWC 5300 Vinyl /Low -E First Floor (1) U- Factor Type: 116 -A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116 -13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t FWd Len I Hclt LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Screen 0.76 _Bug 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Screen 0.76 _Bug EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014- 04- 22T07:21:43 ID: 2014 -4 -22 Page 6 of 16 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name ENCLOSED PATIO ADDITION Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition /Alteration Date 412212014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existing Altered Removed (E) HVAC Split System Sleeping & Living Area 1,602 12,816 1960 Enclosed Patio 262 2,096 Totals 1 2621 1,6021 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status (E) HVAC Split System 1 Central Furnace 75% AFUE Split Air Conditioner 8.0 SEER Setback Existing HVAC DISTRIBUTION S stem Name Heating Coolin Duct Location Duct R -Value Ducts Tested? Status (E) HVAC Split System Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New WATER HEATING SYSTEMS S stem Name Qty Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 3 1 Small Gas Kitchen Pipe Ins 40,000 50 0.58 n/a n/a Existing MULTI - FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft)o iv Z3 ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014 -04- 2 2 70 7:21:43 ID: 2014 -4 -22 Page 7 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name ENCLOSED PATIO ADDITION Date 412212014 NOTE: Low -rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF- 1 R -ALT Form) shall supersede the items marked with an asterisk ( *) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field- fabricated windows) have a label listing the certified U- Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10 -111(a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R -19 insulation in wood -frame ceiling orequivalent U- factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R- Value. *§150(c): Minimum R -13 insulation in wood -frame wall orequivalent U- factor. *§1 50 d : Minimum R -13 insulation in raised wood -frame floor orequivalent U- factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677 -95 2000 when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3 %; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110 - §113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backf low prevention, pump isolation valve, and recirculation loop connection requirements of §1 13(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu /hr are exempt), and pool and spa heaters. 150(h): Heating and /or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R -12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water - heating system, or other indirect hot water tanks have R -12 external insulation or R -16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non - recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150 -B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150 -B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123 -A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water-heating systems and /or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number: 2579 RunCode: 2014- 04 -22T07 :21:43 ID: 2014 -4 -22 Page 8 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date ENCLOSED PATIO ADDITION 412212014 §150(m)1: All air - distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6 -5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct - closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tae shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross - sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI /ASHRAE Standard 62.2 -2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §1 50 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150 -C and is not a low efficacy luminaire asspecified by 150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by 130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150 -C and shall not contain a line- voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §1 50(k). 150(k)7: All switching devices and controls shall meet the requirements of §1 50(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014 -04- 22707:21:43 ID: 2014 -4 -22 Page 9 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ENCLOSED PATIO ADDITION 412212014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §1 50 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing /rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low -rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on /off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception'! to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high fficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non - dwelling spaces of low -rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number: 2579 RunCode: 2014 -04- 22 70 7:21:43 ID: 2014 -4 -22 Page 10 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ENCLOSED PA -fl0 ADDITION Date 4/22/2014 System Name (E) HVAC Split System Floor Area 1,864 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,254 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 55,000 25,759 1,304 1,064 40,366 Total Output (Btuh ) 55,000 0 Output Btuh /s ft 29.5 1,005 1,913 Cooling System 0 0 Output per System 42,000 0 0 0 0 Total Output Btuh 42,000 0 1,304 0 Total Output (Tons) 3.5 1,005 1,913 Total Output (Btuh /s ft) 22.5 Total Output s ft/Ton 532.6 1 27,769 44,191 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm) 1,000 Existing Furnace & Air Conditioner 33,122 6,921 55,000 Airflow cfm /s ft 0.54 Airflow (cfm/Ton) 2857 Outside Air ( %) 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 33,122 6,921 55,000 Jan 1 AM Outside Air cfm /s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 28 IF 66 IF Outside Air Ar 0 cfm Supply Fan AL 1,000 cfm 66 OF 66 IF 105 IF M 0 � I I I Heating Coil 103 OF . _.._ ..._..__...____....._, ROOM 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 88/68 °F 6/62 °F 76/62 °F 5/54 °F Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF AL 1,000 cfm ROOM OOM 76 / 62 OF 75 / 62 IF EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014- 04- 22T07:21:43 ID: 2014 -4 -22 Page 11 of 16 ROOM LOAD SUMMARY 25,759 1,304 1,064 Project Name ENCLOSED PATIO ADDITION 1,254 25,759 Date 412212014 System Name (E) HVAC Split System Floor Area 1,864 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible First Floor Sleeping & Living Area 1 1,080 22,182 1,262 1,080 22,182 1,262 949 36,001 Enclosed Patio 1 174 3,577 43 174 3,577 43 115 4,364 PAGE TOTAL TOTAL* 1,254 25,759 1,304 1,064 40,366 1,254 25,759 1,304 1,064 40,366 * Total includes ventilation load for zonal systems. EnengyPro 5.1 by EnergySoft User Number. 2579 RunCode: 2014- 04- 22T07:21:43 ID: 2014 -4 -22 Page 12 of 16 ROOM HEATING PEAK LOADS Project Name ENCLOSED PATIO ADDITION Date 412212014 ROOM INFORMATION DESIGN CONDITIONS Room Name Sleeping & Living Area Floor Area 1,602.0 ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 40 Btu /hr Default Wall Prior to 1978 1,143.0 0.3560 40 16,276 Double Non Metal Clear 182.0 0.5500 40 4,004 Wood Door 40.0 0.5000 40 800 Slab -On -Grade perim = 203.2 0.7300 40 5,933 Default Roof Prior to 1978 1,602.0 0.0790 40 5,062 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 1,602 X Area another room 8.00 X 0.426 Height ACH Page Total 160 X AT 32,076 = 3,925 TOTAL HOURLY HEAT LOSS FOR ROOM 36,001 EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014 -04- 22707:21:43 ID: 2014 -4 -22 Page 13 of 16 ROOM HEATING PEAK LOADS Project Name ENCLOSED PATIO ADDITION Date 412212014 ROOM INFORMATION DESIGN CONDITIONS Room Name Enclosed Patio Floor Area 262.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F = = = = = = = = = = = = = = = = = = = = = = = 40 Btu /hr R -13 Wall 129.3 0.1020 40 528 IWC 5300 Vinyl /Low -E 130.0 0.3700 40 1,924 Slab -On -Grade perim = 32.4 0.7300 40 946 R -30 Roof Attic 262.0 0.0310 40 325 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 262 X Area another room 8.00 X 0.426 Height ACH Page Total /60] X AT 3,723 = 642 TOTAL HOURLY HEAT LOSS FOR ROOM 4,364 EnergyPro 5.1 by EnergySoft User Number: 2579 RunCode: 2014- 04 -22T07 :21:43 ID: 2014 -4 -22 Page 14 of 16 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date ENCLOSED PATIO ADDITION 412212014 ROOM INFORMATION DESIGN CONDITIONS Room Name Sleeping & Living Area Outdoor Dry Bulb Temperature 88 OF Floor Area 1,602.0 ft2 Outdoor Wet Bulb Temperature 68 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area U- Factor CLTD' Btu /hr Default Wall Prior to 1978 (E) 301.7 X 0.3560 X 13.0 = 1,396 Wood Door (E) 20.0 X 0.5000 X 13.0 = 130 Default Wall Prior to 1978 (S) 372.0 X 0.3560 X 6.0 = 795 Default Wall Prior to 1978 (W) 179.3 X 0.3560 X 13.0 = 830 Default Wall Prior to 1978 (N) 290.0 X 0.3560 X 3.0 = 310 Wood Door (N) 20.0 X 0.5000 X 3.0 = 30 Default Roof Prior to 1978 (N) 1,602.0 X 0.0790 X 37.0 = 4,683 X X = X X = Page Total 8,173 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu /hr Window - Fixed (E) 00 X 27.2 + 40.0 X 68.0 = 2,721 Window - Slider (E) 0.0 X 27.2 + 12.0 X 68.0 = 816 Window - Slider (S) 0.0 X 27.2 + 66.0 X 37.4 = 2,466 Window - Slider (W) 0.0 X 27.2 + 64.0 X 68.0 = 4,353 X + X = X + X - X + X - X + X - X + X - Page Total 1 10,356 Internal Gain Btu /hr Occupants 5.0 Occupants X 230 Btuh /occ. = 1,150 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.077 X 0.65 X 99.20 X 13 = 903 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,182 Latent Gain Btu /hr Occupants Occupants X 200 Btuh /occ. _ 1,000 Infiltration: 4,830 X 0.65 X 9920 X 0.00084 = 262 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,262 EneravPro 5.1 by EnerqvSoft User Number. 2579 RunCode: 2014 -04- 22707:21:43 ID: 2014 -4 -22 Page 15 of 16 ,W, RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date ENCLOSED PATIO ADDITION 412212014 ROOM INFORMATION DESIGN CONDITIONS Room Name Enclosed Patio Outdoor Dry Bulb Temperature 88 OF Floor Area 262.0 ft' Outdoor Wet Bulb Temperature 68 OF Indoor Dry Bulb Temperature 75 OF 1 Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area U- Factor CLTD' Btu /hr R -13 Wall (W) 61.3 X 0.1020 X 13.0 = 81 R -13 Wall (N) 68.0 X 0.1020 X 3.0 = 21 R -30 Roof Attic (N) 262.0 X 0.0310 X 37.0 = 301 X X = X X = X X = X X = X X = X J X = Page Total 403 Items shown with an asterisk ( ") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu /hr New Window - Slider (W) 0.0 X 12.8 + 30.0 X 32.3 = 968 French Doors (W) 0.0 X 12.8 + 40.0 X 32.3 = 1,291 New Window - Sliders (N) 0.0 X 12.8 + 60.0 X 12.8 = 768 X + X - X + X - X + X - X + X - X + X - X +1 X - Page Total 3,027 Internal Gain Btu /hr Occupants 0.0 Occupants X 230 Btuh /occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.077 X 0.65 X 16.22 X 13 = 148 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,577 Latent Gain Btu /hr Occupants Occupants X 200 Btuh /occ. _ Infiltration: 4,830 X 0.65 X 16.22 X 0.00084 = 43 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 43 EneravPro 5.1 by EnerQvSoft User Number: 2579 RunCode: 2014- 04- 22T07:21:43 ID: 2014 -4 -22 Page 16 of 16