Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13040006
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7965 WOODLARK WAY CONTRACTOR: TALENT DECIDE INC PERMIT NO: 13040006 OWNER'S NAME: SREEDHAR VAIDYANATHAN 218 HARDING AVE DATE ISSUED: 06/27/2013 OWNER'S PHONE: 6509967466 LOS GATOS, CA 95030 PHONE NO: (408) 306-3968 C9 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL License CIass 3 Lic. # REBUILD- CONSTRUCT A 1055 SQ FT ONE STORY _ ADDITION; 94 SQ FT FRONT COVERED PORCH; Contractor ,!% e_ itic: _ Dateerl, % //J' REPLACE I hereby affirm that I am licensed under the provisions of Chapter 9 ROOF STRUCTURE AND REMODEL EXISTING (commencing with Section 7000) of Division 3 of the Business & Professions RESIDENCE Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $200000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 36203023.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. 1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAY PERMIT ISSUANCE OR PERMIT to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DA INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply Issued Date: 6 Z3 with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. / Signature Date Q%r �� RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is / / installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(x) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and 1 have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this `y Owner or authorized agent: 2&< Dater permit is issued./ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records, granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7965 WOODLARK WAY CONTRACTOR: TALENT DECIDE INC PERMIT NO: 13040006 OWNER'S NAME: SREEDHAR VAIDYANATHAN 218 HARDING AVE DATE ISSUED: 06/27/2013 OWNER'S PHONE: 6509967466 LOS GATOS, CA 95030 PHONE NO: (408) 306-3968 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL El COMMERCIAL License Class Lic. 4 �'T O �-� REBUILD- CONSTRUCT A 1055 SQ FT ONE STORY ADDITION; 94 SQ FT FRONT COVERED PORCH; Contractor Date/G REPLACE I hereby affirm that I a licensed under the provisions of Chapter 9 ROOF STRUCTURE AND REMODEL EXISTING (commencing with Section 7000) of Division 3 of the Business & Professions RESIDENCE Code and that my license is in full force and effect. REVISION #1- ADD BAY WINDOW, REMOVE F[REPLACE-ISSD I hereby affirm under penalty of perjury one of the following two declarations: OTC 9/16/2013 1 have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft FI Valuation: $200000 performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by ection 3700 of the Labor Code, for the performance of the work for which this N_!>ApP1992030 0 Occupancy Type: permit is issued. APPLICANT CERTIFICATION . I certify that I have read this application and state that the above info RMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and s ws latin WITH 80 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this c' upon the above mentioned property for inspection purposes. (We) agr o save 180 DAY ROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the 9/� �J granting of this permit. Additionally, the applicant understands and will comply Issued by: Date: with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. � �� RE -ROOFS: Signature- L Date - All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(x) should I store or handle hazardous 1 have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505,255 , and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date l�. permit is issued.: 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, 1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date_ CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUPERTINO (408) 777-3228 • FAX (408) 777-3333 • buildingCo)cupertino.org ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI I' REVISION/ DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS �j /_ ✓ ` 1 _ V [ APN # / z 0 h 7 �j/�� V OWNER NAME � ; � , PHON E- AIL STREET ADDRESS O G•/ CITY, STATE, ZIP FAX CONTACT NAME '� PHONE d., 0 G` MAIL( 1•Al JA Ij o STREET ADDRESS 7 RA CITY, STATE, ZIP • FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME -, / LICENSE NUMBER a�v / LICENSE TYPE BUS. LIC # i 7L COMPANY NAME E-MAIL FAX STREET ADDRESS •, J�i /� s���v A�� CITY, STATE, ZIP j i s ���• ,70 !�' I PHONE ,`�_ ARCHITECT/ENGWEER NAME e L EN BE BUS. LIC # COMPANYNAME E-MAIL FAX / STREET ADDRESS ' /• � ` CITY, STATE, ZIP ` , l /'7 �_ (�•p-C PHONE I DESCRIPTION OF WORK�J- Y EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG Ca AREA NEW FLOO'�.R ///��� AREA r7 DEMO AREA TOTAL NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREATOTAL DECKTORCH AREA GARAGE AREA: DETACH ❑ ATTACH # DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY ❑ YES BEING ADDED? ❑ NO ADDITION? ❑ NO / PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEIVER BX.:. ♦ TOT ATIION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO By my signature below, I certify to each following: the property owner or authorized agent to act o{ the property owner's behalf. I have had this application and the information I have vid is correct. ave read the Description of Work and verify it i ccurate. I agree to comply with all applicable local ordinances and state laws relatin to Wing ons ructio I authorize representatives of Cupertino to enter the ab ve-ide ified property for inspection purposes. Signature of Applicant/Agent: e: SUPPLEMEN LINFORMATI REQUIRED LAxCTYp .itCiUTINGSLIF: T7iCOUIVT�R °� GPLANREvlTVv ' _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS PLANNING i1LAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ ?VBLICwoRKs , form if any Hazardous Materials are being used as part of this project. ❑ ARCS ❑ I?IAD_u DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to MLTGR �A1VIl"ARYSEWERD7STWCT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH B1dgApp_2011.doc revised 06/21/11 CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(@cupertino.org ❑ NEW CONSTRUCTION _VIADDITION ❑ ALTERATION/ Ti ❑ REVISION/ DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS iII APN# p7 OWNER NAME a�/V / PHO CI G—�s. % E-MAIL a' K r STREET ADDRESS / CITY, STATE`, ZIP PHO CONTACT NAMEL, ck / MAIL TLA BB � a ^ STREET ADDRESS I O CITY, STATE, ZIP AX a UXARCHITECT ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT ❑ CONTRACTOR❑CONTRACTOR AGENT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME �J LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEERNAME T"" L� LIC ENSENLJMBER,,,,/ffC- BUS. LIC# COMPANY NAME ��" w (� E-MAIL ( 7 A ` �Qa ` U FAX STREET ADDRESS 2 �, I O /' /I,fAN �; r� G!,` CITY, STATE, ZIP-,` �� PHONE J t s DESCRIPTION OF WORK �j I�©� as EXISTING USE PROPOSED USE CONSTR. T E #STORIES USE TYPE OCC. SQ.FT. VALUATION (S) EXLSTG NEW FLOORDEMO TOTAL AREA QO C/ AREA1655' AREA NET AREA +�J (- BATHROOM h/.. REMODELAREA 5 KITCHEN REMODELAREA OTHER REMODELAREA V PORC DECK AREA TOTAL DECK/PO H AREA (Lln GARAGE AREA; DETACH �' (� ATTACH ,❑`YES # DWELLING UNITS: ISA SECOND UNIT ❑�YES SECOND STORY BEING ADDED? W, ADDITION? ' r `[]\YES FFTF PRE -APPLICATION YES IF YES, PROVIDE COPY OF IS THE BLDG AN RE TOTAL VALUATION: PLANNING ADPL# 0 LANNINGAPP LLETTER EICHLER HOME? IS:NO 004::>00 ty owner -or o ' t to act n the pr rty owner's behalf. I have read this By my signature below, I certify to each of a owing: I aKresentatives application and the inforrnation I ha a pr, ed is rect. I hDescriptio ork and verify it i e. I agree to comply with aII applicable local ordinances and state laws relating to d' g cons ctio . I of Cupertino to enter the above -id tified p perty for inspection purposes. Signature ofApplicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP New SFD or Multifamily dwellings: Apply for demolition permit for ❑ OVER-THE-COUNTER ❑ BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to EJ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_2011.doc revised 06/21/11 Lf W CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION ADDRESS: 7965 woodlard I DATE: 09/16/2013 1 REVIEWED BY: Mendez APN: BP#: ' fjoy000b *VALUATION: Iso *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION 1GENRES USE: PERMIT TYPE: wORK REVISION #1- ADD BAY WINDOW REMOVE FIREPLACE-ISSD OTC 9/16/2013 SCOPE NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District etc ). These fees are haled an the nreliminary information available and are only an estimate. Contact the Dent for addn 7 info. FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: Hourly Only? 0 Yes Q No $0.00 F__17 hours Plan Check, Hourly $139.00f 1STPLNCx Suppl. PC Fee: Q Reg. 0 OT 0.0 hr's $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. Q OT F0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 ire%It"tttll.;l"c:ilt'c' 1'.'('' Work Without Permit? 0 Yes No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure 0 7�cnc�l 1)f,c�ur�t,,«tu=`ic�r? ?°`�,r�^s: Strong Motion Fee: $0.00 Select an Administrative Item Bldg Stds Commission Fee: $0.00 SUBTOTALS: ` $0.001 $139.00 TOTAL FEE: $139.00 Revised: 08/01/2013 CITY OF CUPERTINO FM_7 FEE ESTIMATOR - BUILDING DIVISION imADDRESS: 7965 WOODLARK WAY DATE: 04/0112013 REVIEWED BY: MELISSA PC FEE ID APN: 362 03 023 BP#: i36 4106y *VALUATION: 1$200,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: 2nd Unit? Yes No OTC. 0 Yes (F)No PENTAMATION 1R3SFDADD PERMIT TYPE: WORK ADDTION OF 1055 SQ FT N KITCHEN N FAMILY RM N MASTER BED & BATH AND N SCOPE STUDY. REMODEL (E) BATHROOM OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,111-B,IV,V-B 1,055 $2,487.18 IR3PLNCK $1,617.73 IR3INSP $0.00 PME Plan Check: $0.00 Permit Fee: $1,617.73 Suppl. Insp. Fee:Q Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: TOTALS: 1,05 $2,487.18 $1,617.73 MECH, HOURLY Q Yes Q No ' PLUMB, HOURLY 0 Yes Q No ELEC, HOURLY Q Yes Q No EI El NOTE. This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School Dictrirt etc)- Thoce foes are hacod nn the nreliminary informatinn availahle and aro nnly an ostimaty_ Cnntart the Dent for addn'1 infn_ FEE ITEMS (Fee Resolution 11-Oi3 Eff 7/1/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,487.18 L_88_j s.f. $600.00 Remodel, Bath (<=300 sf) 1REMRESBAT Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $1,617.73 Suppl. Insp. Fee:Q Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 ,, %1dij,",,I, 114)1 vii' f'cf,: E) Work Without Permit? C) Yes Q No $0.00 Advanced Planning Fee: IPLLONGR $137.15 Select a Non -Residential Building or Structure Q 0 A '!"V,ft el; 1), u; r, r;r,air' = l '=r<.: Strong Motion Fee: IBSEISMICR $20.00 Select an Administrative Item Bldg, Stds Commission Fee: IBCBSC $8.00 SUBTOTALS: $4,270.06 $600.00 'TOTAL FEE: $4,870.06 Revised: 04/01/2013 CUPERTINO CONTRACTOR / SUBCONTRACTOR LIST Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 9501473255 Telephone: 408-77..1-3228 Fax: 408- 7-3333 JOB ADDRESS:7f�,5- A 4 Wt1 PERMIT # l3 OWNER'S NAME; =' PHONE # 40P GENERAL CONTRACTOR: ' BUSINESS LICENSE # ADDRESS:.:)!,* CITY/ZIPCODE: 4i' *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: X-- ' Owner / Cont actor75i—gnature Dat SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millworkev ». 1 Cement Finishing Electrical�'�� Excavation Fencing Flooring / Carpeting C SOL Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry L,C Painting / Wallpaper Paving Plastering Plumbing U� Roofing ,9Z Septic Tank Sheet Metal Sheet Rock Tile X-- ' Owner / Cont actor75i—gnature Dat t 1 I BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. Sree Vaidyanathan Residence 7965 Woodlark Way Cupertino, CA 95014 Project Designer: Thomas Liu & Associ CIJPERTINO 20710 Carni-A Av rluudIng Department Saratoga, CA 950 408-867-88784.n_�s¢ 1 2013 ' :UDE COMPLIANCE Report Prepared by: Mark Chu Mark Chu & Associates 1141 S. Stelling Road Cupertino, CA 95014 (408) 255-4804 Job Number: 03231 "OFFICE COP��.s Date: � 3!23/2013 SUBMITTAL #1 APR 01 2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-03-23712:07:15 ID: 032313 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. Sree Vaidyanathan Residence Building Type m Single Family ❑ Addition Alone 0 Multi Family m Existing+ Addition/Alteration Date 3/23/2013 Project Address 7965 Woodlark Way Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,235 Addition 1,055 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity 02) Features see Part 2 of 5) Status Wall Wood Framed None 767 Existing Door Opaque Door None 34 New Floor Wood Framed w/Crawl Space None 1,180 Existing Roof Wood Framed Attic R-13 1,150 Existing Roof Wood Framed Attic R-30 1,055 Radiant Barrier New well Wood Framed R-13 604 New Floor Wood Framed w/o Crawl Space R-19 1,055 New FENESTRATION U- Orientation Area(fe) Factor Exterior SHGC Overhang Sidefins Shades Status Front (S) 54.0 0.370 0.32 none none Bug Screen New Left (W) 60.0 0.370 0.32 none none Bug Screen New Skylight 30.0 0.550 0.67 none none None New Rear (N) 124.5 0.370 0.32 none none Bug Screen New Right (E) 54.0 0.370 0.32 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Fumace 93%AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Res HVAC Ducted Ducted Crawlspece 6.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 75 0.59 No Pipe Insulation New EnergyPro 5.1 by Ener Soft User Number. 4970 RunCode: 2013-03-23T12:07:15 1D: 032313 Pa e 2 of 10 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mr. Sree Vaidyanathan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family la Existing+ Addition/Alteration Date 3/23/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-30 Roof Attic with Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnergyPro 5.1 by Ener Soft User Number: 4970 Run Code: 2013-03-23T12:07:15 ID: 032313 Page 3 of 12J PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. Sree Vaidyanathan Residence ❑ Multi Family [Z Existing+ Addition/Alteration 3/23/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV (kBtu/ft2 r Space Heating 40.72 29.90 10.82 Space Cooling 16.83 12.09 4.74 Fans 8.90 7.19 1.71 Domestic Hot Water 17.74 17.78 -0.04 Pumps 0.00 0.00 0.00 Totals 84.20 66.97 17.23 Percent Better Than Standard: 20.5% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 198 54 Fuel Available at Site: Natural Gas (W 462 60 Raised Floor Area: 2,235 (N) 344 125 Slab on Grade Area: 0 (E) 692 54 Average Ceiling Height: 8.0 Root 2,235 30 Fenestration Average U-Factor: 0.37 TOTAL: 323 Average SHGC: 0.32 Fenestration/CFA Ratio: 14.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author �}�f Mark Chu & Associates Company 3/23/2013 Address 1141 S. Stelling Road Name Mark Chu City/State/Zip Cupertino, CA 95014 Phone (408) 255-4804 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) r Company Thomas Liu & Associates 20710 Camiel Ave. Thomas Liu Address Name City/State/Zip Saratoga, CA 95070 Phone 408-867-8878 Signed License # Date Ener Pro 5.1 by EnerqySoft User Number 4970 RunCode: 2013-03-23T12:07:15 ID: 032313 Page 4 of 10 I� CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. Sree Vaidyanathan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family [0 Existing+ Addition/Alteration Date 3/23/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 111 0.356 None 180 90 Existing 4.3.1-A 1 1st Floor Zone E) Door 34 0.500 None 180 90 New 4.5.1-A4 1st Floor Zone (E Wall 298 0.356 None 270 90 Existing 4.3.1-A1 1st Floor Zone (E Wall 198 0.356 None J 0 90 Remove 4.3.1-A 1 1st Floor Zone E Wall 128 0.356 None 90 90 Existing 4.3.1-A1 1st Floor Zone E) Floor 1,180 0.097 None 0 180 Existing 4.4.1-A 1 1 st Floor Zone E Roof 1,150 0.068 R-13 0 22 Existing 4.2.1-A 15 1st Floor Zone (E) Wall 230 0.356 None 90 90 Existing 4.3.1-A 1 1st Floor Zone (E) Roof 1,055 0.031 R-30 0 22 New 4.2.1-A20 1st Floor Zone N Wall 104 0.102 R-13 270 90 New 4.3.1-A3 1st Floor Zone (N) Wall 220 0.102 R-13 0 90 New 4.3.1-A3 1st Floor Zone (N) Wall 280 0.102 R-13 90 90 New 4.3.1-A3 1st Floor Zone N Floor 1,055 0.048 R-19 0 180 New 4.4.244 1st Floor Zone N FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 10.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vinyl/Low-E 1st Floor Zone (E) 2 Window 9.5 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vinyl/Low-E 1 st Floor Zone (E) 3 Window 25.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vinyl/Low-E 1st Floor Zone (E) 4 Window 9.5 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vinyl/Low-E 1st Floor Zone (E) 5 Window 6.0 0.370 NFRC 0.32 NFRC 1 2701 New IWC 5300 Vinyl/Low-E 1st Floor Zone (E) 6 Window 24.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 Vinyl/Low-E 1 st Floor Zone (E) 7 Window 6.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 Vinyl/Low-E ist Floor Zone (E) 8 Window 24.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 Vinyl/Low-E 1st Floor Zone (E) 9 Skylight 30.0 0.550 Default 0.67 Default 0 New Velux (3x2) 1st Floor Zone (E) 10 Window 53.5 0.370 NFRC 0.32 NFRC 0 New IWC 5300 Vinyl/Low-E 1st Floor Zone (N) 11 Window 17.5 0.370 NFRC 0.32 NFRC 0 New IWC 5300 Vinyl/Low-E 1st Floor Zone (N) 12 Window 53.5 0.370 NFRC 0.32 NFRC 0 New IWC 5300 Vinyl/Low-E 1st Floor Zone (N) 13 Window 15.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vinyl/Low-E 1st Floor Zone (N) 14 Window 15.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vinyl/Loiv-E 1st Floor Zone (N) 15 Window 24.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vinyl/Low-E 1st Floor Zone (N) (1) U -Factor Type: 116-A =Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window Overhanq Left Fin Ri ht Fin SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 None 1.00 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 4970 RunCode: 2013-03-23712:07:15 1D: 032313 Page 5 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. Sree Vaidyanathan Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 3/23/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Res HVAC 1st Floor (E) 1,180 9,440 1963 1st Floor (N) 1,055 8,440 Totals 1,055 1,180 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Res HVAC 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Res HVAC Ducted Ducted Crawlspace 6.0 ❑ New El WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Rheem PVW75-75FV 1 Small Gas No Pipe Insulation 75,000 75 0.59 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 i� �v ¢ — System Name Pipe Len th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried El EnergyPro 5.1 by EnerqySoft User Number: 4970 Run Code: 2013-03-23T12:07:15 ID: 032313 Page 6 of 10 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Mr. Sree Vaidyanathan Residence Date 3/23/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §11 B(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent 1 -1 -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. .§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d :Minimum R-13 insulation in raised wood frame floor or e uivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: '150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 byEnergySoft User Number: 4970 Run Code: 2013-03-23T12:07:15 ID: 032313 Page 7 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. Sree Vaidyanathan Residence 3/23/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers, §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified b 150(k).2. 150(k)3-. The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-03-23T12:07:15 ID: 032313 Page 8 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr. Sree Vaidyanathan Residence 3/23/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11 : Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shalt be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-03-23T12:07:15 ID: 032313 Page 9 of 10 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Mr. Sree Vaidyanathan Residence 3/23/2013 System Name Floor Area Res HVAC 2,235 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 1 COIL COOLING PEAK COIL HTG. PEAK Heating System Output per System 113,000 Total Room Loads Total Output (Stuh) 113,000 Return Vented Lighting Output Btuh/s ft 50.6 Return Air Ducts Cooling System Return Fan Output per System 46,300 Ventilation [ Total Output Btuh 46,300 Supply Fan Total Output (Tons) 3.9 Supply Air Ducts Total Output (Btuh/s ft) 20.7 Total Output s ft/Ton 579.3 TOTAL SYSTEM LOAD Air System CFM perSystem 1,650 HVAC EQUIPMENT SELECTION Airflow cfm 1,650 Carrier 58MTB120-20 CNP 38HD 4 T Airflow cfm/s ft) 0.74 Airflow cfm/Ton 427.6 Outside Air (%) 0.0% Total Adjusted System Output Outside Air cfm/s ft) 0.00 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of 28 IF 69 IF 69 OF 132 OF Bonn Outside Air 0 cfm Supply Fan Heating Coil 1,650 cfm 69 OF CFM Sensible Latent CFM Sensible 877 21,925 765 567 37,436 0 687 2,039 0 0 0 0 0 0 0 0 0 687 2,039 23,299 765 41,514 42,6021 0I 113,0001 42,602 01 1 113,000 Aug 3 PM Jan 1 AM COOLING SYSTEM PSYCHROMETICS Airstream Tem eratures at Time of Cooling Peak) 88168'F 75160 IF 75159 IF 51 150 OF 60 Outside Air Supply Fan 52150 OF 0 cfm Cooling Coil 1,650 cfm 39.6% ROO M In 75160 OF 75159 IF i RA EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-03-23T12:07:15 ID: 032313 Page 10 of 10