B-2017-0383CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0383 10123 HILLCREST RD CUPERTINO, CA 95014-1049 (326 16 057) SUNRUN SERVICES INC SAN LUIS OBISPO, CA 93401 OWNER'S NAME: WOOLFOLK JOHN W III AND KAY G TRUSTEE I I DATE ISSUED: 03/08/2017 I OWNER'S PHONE: 408-835-9892 I I PHONE NO: (415) 580-6900 LICENSED CONTRACTOR'S DECLARATION License Class C-46 Lic. #750184 Contractor SUNRUN INSTALLATION SERVICES INC Date 06/30/2018 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2.` I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulatigng per th)jio'e�ino Municipal Code, Section 9.18. Date 3/8/2017 I hereby affirm that Lafn exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code; for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions ofthe Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked.. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 3/8/2017 BUILDING PERMIT INFO: BLDG X ELECT —PLUMB MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: (N) 34 -PANEL ROOF MOUNTED PV SYSTEM (9.0 KW); (l) MAIN BREAKER (100 AMP) Sq. Ft Floor Area: J Valuation: $18090.00 "N Number: Occupancy Type: 326 16 057 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. by: Abby RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date:/83 /2017 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertin 'cipal Code, Chapter 9.12 and the Health & Safety Code, ec ' 25 5, 25533, and 25534. Owner or authorized agent: Date: 3/8/2017 CON IRA CTI LE ING AGENCY 1 hereby affirm that there is a consipiet6n lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION understand my plans shall be used as public records. Licensed )-�-w ig - n� 3 ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildinq(a)-cupertino.org PROJECT ADDRESS 10123 Hillcrest Road APN# 32616057 OWNER NAME John Woolfolk PHONE (4708) 835-9892 E-MAIL woolfolk@comcast.net STREET ADDRESS 10123 Hillcrest Road CITY, STATE, ZIP Cupertino, CA 95014 FAX CONTACT NAME Vance Jason PHONE (408) 506-3693 E-MAIL vance.jason@sunrunhome.co STREET ADDRESS SAME AS CONTRACTOR CITY, STATE, ZIP FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME S u n ru n TLICENSENUM13ER 750184 LICENSE TYPE C-46 BUS. LIC # 27932 COMPANY NAME Sunrun E-MAIL FAX (408) 894-9294 STREET ADDRESS 575 Dado St CITY, STATE, ZIP San Jose, CA 95131 PHONE (408) 747-2487 ARCHITECT/ENGINEERNAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX - STREET ADDRESS CITY, STATE, ZIP PHONE �,/ LV' USE OF SFD Or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: El Commercial 1/ URBAN INTERFACE AREA Eli� Yes NO FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION TO SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: 34 KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: $ 18090.00 DESCRIPTION OF WORK 9.0 kW PV (34) MODULE SOLAR ROOFTOP INSTALLATION, NEW 100A MAIN BREAKER RECEIVED BY: QA By my signature below, I certify to each of thy following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information III ,prov' ed is c have read the Description of Work and verify itis accurate. I agree to comply with all applicable local ordinances and state laws relating t ui ng co do I authorize representatives of Cupertino to enter the above-identifedprope for inspection purposes. Date: /c Signature of Applicant/Agent: PPLE NT INFORMATION REQUIRED OFFICE USE ONLY ❑ OYER -THE -COUNTER ❑ EXPRESS - u x ❑ STANDARD 77 /L LARGE W ❑ MAJOR PVApp 2011. doe revised 03/16/11 CUpERTINO SMOKE 1 CARSON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE o CUPERTINO, CA 95014-3255 (408) 777-3228 a FAX (408) 777-3333 • building(c)cupertino.org PERMT CANNOT BE FINALED UNTIL THIS CERTIFICATE HAS BEEN COMPLETED, 5LQjL). AND UTURMD TO THE BUILDING DIVISION PURPOSE Thisaffidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314, R315, 2016 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314, R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM ' Outside of each separate sleeph-ig area in the immediate vicinity of the X X bedroom(s)- (Smoke alarms shall not be located within 3 feet of bathroom door) Signature...................................................................... Lic.#........................................ Date:................... Or: every level of a dwelling unit including basements and habitable attics X X _ Within eachsleeper room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply tivi"rh CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the .removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below. t Address: ! (f Z3 Y/ /h Permit No. -&-- -- Z6'l - a3 Y3 Specify Number of Alarms: # Smoke Alarms: # Carbon Monoxide Detectors: 1 L s l have read and agree to comply with the terms and conditions of this statement Owner (or Owner Agent's) Name: o�14 Si natur ................... Date:.%!. Contr ctor Name: Signature...................................................................... Lic.#........................................ Date:................... Smoke and COform.doe revised 01/10/2017 CUPERTINt3 WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT , BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • build Ing(a.cupertino.org Owner Name 41 ev ki, tel_ i A,' CC.-> Wa I k Am" Permit No. L' /7 -" 03 �3 Address 10 1 Z 3 � j''` j r• ,�. � t l�9 1. Is your real property a registered historical site? . ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. C"No Go to Question 2. Does your real property have a licensed plumber certifyingthat, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. V No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Xes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101:.1. through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. [(Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. Plgjase check ONE of the following: My property is a single family residential real property. See Civil Code Section 1101.4. On and. after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multii mnily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout.the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures. in accordance with Civil Code Sections 1101.1, through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. Owner or Owner Agent's Signature Date: 1 Upon completing and sigmng tans c:ertrtrcate, please return it to the burudmg lirvrsron in oraer to nnai your nursing permit. SB407 2015.doc revised 08/26/15 1. If the existing plumbing fixture water usage/flotu rate is equal to or lower than the figure shown, it is not required to be upgraded. SE407 2015.doc revised 08/26/15 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixture (Fixture Complying with Current Code Applicable to New Construction) Fixture Type Maximum Water Usage/Flow Rate 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 Water Usage /Flow Rate 2013 CALGreen D,v. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toil ets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of - gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not - exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 _gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flotu rate is equal to or lower than the figure shown, it is not required to be upgraded. SE407 2015.doc revised 08/26/15 SCOPE OF WORK • SYSTEM SIZE: 901 OW DC, 7600W AC • MODULES: (34) CANADIAN SOLAR: CS6P-265P • INVERTER(S): (1) SOLAREDGE TECHNOLOGIES: SE 760OA-US (240V) • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT SEE PEN D01. • MAIN BREAKER DERATE: REPLACE EXISTING MAIN BREAKER WITH NEW 100 AMP MAIN BREAKER. VICINITY MAP a F C Q rP ror 107 z8 N3licrest itoaa Sunny View Bay Area Retirement Community 'Sunny View West G 7" 11 p.- ­rri F:d 'elt, Yi nes LLP Sie��ns U1tr-k L1vd 4 GENERAL NOTES • ALL WORK SHALL COMPLY WITH 2016 CEC, 2016 CBC, 2016 CRC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2016 CEC. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2016 CEC. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. 14.42 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)) CUPERTINO Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By: Kim Dunbar n-- 03/08/17 LEGEND AND ABBREVIATIONS SE SERVICE ENTRANCE MP MAIN PANEL SP SUB -PANEL LC PV LOAD CENTER SM SUNRUN METER PM DEDICATED PV METER INVERTER(S) WITH INV INTEGRATED DC DISCONNECT AND AFCI 91E]ACDISCONNECT(S) DC DISCONNECT(S) 9 B COMBINER BOX CB F_ —1 INTERIOR EQUIPMENT LE a SHOWN AS DASHED SOLAR MODULES RAIL STANDOFFS & FOOTINGS CHIMNEY ATTIC VENT FLUSH ATTIC VENT 0 PVC PIPE VENT ® METAL PIPE VENT ® T -VENT SATELLITE DISH PV -1.0 1z FIRE SETBACKS SITE PLAN PV -3.0 LAYOUT This s GENERAL NOTES • ALL WORK SHALL COMPLY WITH 2016 CEC, 2016 CBC, 2016 CRC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2016 CEC. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2016 CEC. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. 14.42 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)) CUPERTINO Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By: Kim Dunbar n-- 03/08/17 LEGEND AND ABBREVIATIONS SE SERVICE ENTRANCE MP MAIN PANEL SP SUB -PANEL LC PV LOAD CENTER SM SUNRUN METER PM DEDICATED PV METER INVERTER(S) WITH INV INTEGRATED DC DISCONNECT AND AFCI 91E]ACDISCONNECT(S) DC DISCONNECT(S) 9 B COMBINER BOX CB F_ —1 INTERIOR EQUIPMENT LE a SHOWN AS DASHED SOLAR MODULES RAIL STANDOFFS & FOOTINGS CHIMNEY ATTIC VENT FLUSH ATTIC VENT 0 PVC PIPE VENT ® METAL PIPE VENT ® T -VENT A AMPERE BY AC ALTERNATING CURRENT DATE AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH PERMIT COMP COMPOSITION DC DIRECTCURRENT (E) EXISTING EXT EXTERIOR FIRM FRAMING INT INTERIOR LBW LOAD BEARING WALL MAG MAGNETIC MSP MAIN SERVICE PANEL (N) NEW NTS NOT TO SCALE OC ON CENTER PRE -FAB PRE -FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS V NAME DATE COMMENTS TABLE OF CONTENTS SATELLITE DISH PV -1.0 1z FIRE SETBACKS SITE PLAN PV -3.0 LAYOUT This s ID HARDSCAPE site du alterati — PL— PROPERTY LINE The at SCALE: NTBId A AMPERE BY AC ALTERNATING CURRENT DATE AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH PERMIT COMP COMPOSITION DC DIRECTCURRENT (E) EXISTING EXT EXTERIOR FIRM FRAMING INT INTERIOR LBW LOAD BEARING WALL MAG MAGNETIC MSP MAIN SERVICE PANEL (N) NEW NTS NOT TO SCALE OC ON CENTER PRE -FAB PRE -FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS V NAME DATE COMMENTS TABLE OF CONTENTS PAGE # DESCRIPTION PV -1.0 COVER SHEET PV -2.0 SITE PLAN PV -3.0 LAYOUT PV -4.0 ELECTRICAL PV -5.0 SIGNAGE COMMUNITY DEVELOPMENT DEPARTN BUILDING DIVISION—CUPERTINO APPROVED plans and specifications MUST be kept at the construction. It is unlawful to make any change Tfrom theABuildine Official. Ordinance or State Law. CUSTOMER RESIDENCE: JOHN WOOLFOLK 10123 HILLCREST ROAD, CUPERTINO, CA, 95014 TEL. (408) 835-9892APN #'. 32616057 PROJECT NUMBER: 102R-123WOOL DESIGNER: DEREK CARTWRIGHT DRAFTER: DEREK CARTWRIGHT SHEET COVER SHEET REV: A 3/3/2017 PAGE PV -1.0 SITE PLAN - SCALE = 1/16" = V-0" PITCH TRUE MAG PV AREA AZIM AZIM (SOFT) ® AR -01 18° 1750 1610 86.7 AR -02 180 850 710 156 AR -03 180 850 710 346.7 (E) POOL - pL - PL PL PL 32'-1 " r (N) ARRAY AR -03 SM INV ® 13'-5— (N) ARRAY AR -01 MP SUnrUn 39'_1 1 a. (E)GATE GILBERT CORREIA, C10, C46 (N) ARRAY AR -02 CA CL #750184 575DADO ST , SPIN JOSE, CA95131 PHONE 4S' 74 7 2487 FM 408 894 9294 FIRE SETBACKS - , a (3. TYP) CUSTOMER RESIDENCE: ° JOHN WOOLFOLK 10123 HILLCREST ROAD, a r CUPERTINO, CA, 95014 a °.a 7J TEL. (408) 835-9892APN #'. 32616057 1T-10" a° (n PROJECT NUMBER: a a a 4 4 102R-123WOOL PL PL a ° <. , , p DESIGNER: ---- DEREK CARTWRIGHT DRAFTER: (E) GATE DEREK CARTWRIGHT (E) RESIDENCE SHEET F91 CUPERTINO Building Department SITE PLAN REV: A 3/3/2017 REVIEWED FOR CODE COMPLIANCE PAGE PV -2.0 Reviewed By: Kim Dunbar nnro- 03/08/17 Date: uaivai_i7 ROOF FRAME FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA ROOF TYPE ATTACHMENT ROOF HEIGHT EXPOSURE MATERIAL FRAME TYPE SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR -01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 9'- 7" 24" T- 0" 6'- 0" 2'- 8" CANADIAN SOLAR: CS6P-265P MODULE DIMS: AR -02 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 9'- 7" 24" T- 0" 6'- 0" 2'- 8" 64.5" x 38.7" x 1.57" AR -03 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 9'- 7" 24" T- 0" 6'- 0" 2'- 8" MODULE CLAMPS: D1 - AR -01 - SCALE: 3/16" = V-0" D2 - AR -02 - SCALE: 1/8" = 1'-0" Portrait: 13.39" - 16.14" Landscape: 7.87" - 9.84" PITCH: 18° PITCH: 18° MAX DISTRIBUTED LOAD: 3 PSF AZIM:175' AZIM:85° SNOW LOAD: 0 PSF ® ® WIND SPEED: 110 MPH 3 -SEC GUST. LAG SCREWS: 10'-9" 16'-3" —3'-5/16"x4.0": 2.5" MIN EMBEDMENT —4--10"— N OTE: INSTALLERS TO VERIFY RAFTER 2 X 6 RAFTER 24" OC SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE 3' ri PROCEEDING. —I- �Ip �Iq 6' TYP �" T I I3 Q=6' TYP— 6._6" sunrun 21'7" 2 X 6 RAFTER 24" OC G I LB ERT GGRREIA, 110, 146 CA CL #750184 D3 - AR -03 - SCALE: 1/8" = 1'-0" PITCH: 18° aC"95131 AZIM: 85' 4088949 94 RIDGE BOARD CUSTOMER RESIDENCE: ® 3'— 26'-1" T-8" 9'-9" —3'— JOHN 5/16" X 4.0" LAG SCREW. HILOLOCR ST ROAD, ��10123 3' 3' 1 BOLT PER PENETRATION CUPERTINO, CA, 95014 COMP SHI NGLE ROOF TEL. (408) 835-9892APN # 32616057 ® PROJECT NUMBER: —6' TYP SOLAR MODULE 102R-123WOOL 10'-101, 0 10'-10" TOP PLATE DESIGNER, DESIGNER ____ : CARTWRIGHT O 2X6 RAFTERS, 24" O.C.--//DEREK DRAFTER: / 0 — TT�T—�r'T LOAD BEARING WALLCUPERTINO DEREK CARTWRIGHT T2X6RAFTER24"OC SHEETBuilding LAYOUT Department \ REV: A 3/3/2017 REVIEWED FOR CODE COMPLIANCE PAGE PV -3.0 Reviewed By: Kim Dunbar Date: uaivai_i7 120/240 VAC SINGLE PHASE SERVICE OMETER#: M PG&E 1009266877 UTILITY GRID SOLAREDGE TECHNOLOGIES: SE 760OA-US (240V) 7600 WATT INVERTER JUNCTION BOX OR EQUIVALEN 3 1 A /-2 40A PV 250V METER SOCKET LOAD RATED DC DISCONNECT BREAKER AS 125A CONTINUOUS & WITH INTEGRATED RAPID FARAWAY FROM 240V METER SHUTDOWN & AFCI MAIN BREAKER 200A, FORM 2S AS POSSIBLE PV MODULES 1 CANADIAN SOLAR: CS6P-265P ✓j (34) MODULES (?� % OPTIMIZERS WIRED IN (1) SERIES OF (17) `Y OPTIMIZERS AND (1) SERIES OF (17) OPTIMIZERS SOLAREDGE POWER OPTIMIZER P300 CONDUIT SCHEDULE EXISTING # CONDUIT 100A MAIN NEUTRAL GROUND BREAKER NONE 1 (CENTER FED) (1) 10 AWG BARE COPPER 2 EXISTING (N) SUN RUN (4) 10 AWG THHN/THWN-2 NONE 125A CENTRON 4G FACILITY 3/4" EMT OR EQUIV. MAIN METER (1) 10 AWG THHN/THWN-2 LOADS PANEL 3 O SOLAREDGE TECHNOLOGIES: SE 760OA-US (240V) 7600 WATT INVERTER JUNCTION BOX OR EQUIVALEN 3 1 A /-2 40A PV 250V METER SOCKET LOAD RATED DC DISCONNECT BREAKER AS 125A CONTINUOUS & WITH INTEGRATED RAPID FARAWAY FROM 240V METER SHUTDOWN & AFCI MAIN BREAKER 200A, FORM 2S AS POSSIBLE PV MODULES 1 CANADIAN SOLAR: CS6P-265P ✓j (34) MODULES (?� % OPTIMIZERS WIRED IN (1) SERIES OF (17) `Y OPTIMIZERS AND (1) SERIES OF (17) OPTIMIZERS SOLAREDGE POWER OPTIMIZER P300 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 NOTES TO INSTALLER: 1. 17 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. INSTALL WATER BOND WITHIN 5 FT OF WHERE THE WATER MAIN ENTER THE HOUSE. 3. REPLACE EXISTING MAIN BREAKER WITH 100 AMP MAIN BREAKER. 4. ADD 40 AMP PV BREAKER TO MAIN PANEL. 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER — (TORQUE TO 16 FTLBS) \ \ SNAPNRACK \ GROUNDLUG /tSSS 1iMODULE CHARACTERISTICS P300 OPTIMIZER CHARACTERISTICS: ( ONDING CHANNEL CANADIAN SOLAR: MIN INPUT VOLTAGE: 8 VDC /CS6P-265P: Nur 265 W MAX INPUT VOLTAGE: 48 VDC OPEN CIRCUIT VOLTAGE: 37.7 V MAX INPUT ISC: 10 ADC NDING RAIL MAX POWER VOLTAGE: 30.6 V MAX OUTPUT CURRENT: 15 ADC PINS SHORT CIRCUIT CURRENT: 9.23 A NorE. . ALL HARDWARE IS INCLUDED FROM MANUFACTURER • A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY SYSTEM CHARACTERISTICS - INVERTER 1 CONTINUOUS ROW OF MODULES • GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL SYSTEM SIZE: 9010 W CUPERTINO • GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL SYSTEM OPEN CIRCUIT VOLTAGE: 17V OR PERPENDICULAR TO RAIL SYSTEM OPERATING VOLTAGE: 350 V \ Building Department • ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE MAX ALLOWABLE DC VOLTAGE: 500 V SNAPNRACK GROUNDING SCALE: NTS SYSTEM OPERATING CURRENT: 25.7 A SYSTEM SHORT CIRCUIT CURRENT: 30 A REVIEWED FOR CODE COMPLIANCE Reviewed By: Kim Dunbar ,-- 03/08/17 LABEL LOCATION. INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2016:690.17(E), NEC 2014:690.17(E), NEC 2011: 690.17(4) LABEL LOCATION. INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): CEC 2016:690.5(C), NEC 2014:690.5(C), NEC 2011: 690.5(C) LABEL LOCATION. INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2016:690.35(F), NEC 2014: 690.35(F), NEC 2011: 690.35(F) INVERTER1 LABEL LOCATION: o • 30 INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. LABEL LOCATION. PER CODE(S): CEC 2016: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), INVERTER(S), DC DISCONNECT(S). 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 PER CODE(S): CEC 2016:690.53, NEC 2014:690.53, NEC 2011: 690.53 LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, OR AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2016: 690.12, NEC 690.56, NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PERCODE(S): CEC 2016: 690.54, NEC 2014:690.54, NEC 2011: 690.54 LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CoDE(S): CEC 2016: 705.12(D)(3), NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) LABEL LOCATION. ADJACENT TO PV BREAKER (IF LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). APPLICABLE). PER CODE(S): CEC 2016: PER CODE(S): CEC 2016: 705.12(D)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) REVIEWED LABEL LOCATION. MAIN SERVICE PANEL ADJACENT TO MAIN SERVICE BREAKER. PER CODE(S): PER CODE(S): NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 AND NEC 2014ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN, UNLESS PORTIONS OF LABELS OR MARKINGS ARE VARIABLE, OR THAT COULD BE SUBJECT TO CHANGES, SHALL BE PERMITTED TO BE HAND WRITTEN AND SHALL BE LEGIBLE. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN r7 SOLAR PANELS ON ROOF INVERTER LOCATION SUNRUN METER SERVICE ENTRANCE AND PV CUPERTINO BREAKER DISCONNECT ilding Department 10123 HILLCREST ROAD, CUPERTINO, CA, 95014 iD rnnD rnnn Di ienira Reviewed By: Kim Dunbar n-- 03/08/17