B-2017-0426CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS:
1658 S STELLING RD CUPERTINO, CA 95014-5232 (366 24 044)
OWNER'S NAME: COOK MICHAEL J AND SONJA L TRUSTEE
OWNER'S PHONE: 408-996-6745
LICENSED CONTRACTOR'S DECLARATION
License Class C=20 Lie. #740999
Contractor BIGHAM SERVICES INCDate 10/3112017
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
1. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
r r.' I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
and state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
may accrue against said City in consequence of the granting of this permit.
Additionally, the applicant understands and will comply with all non -point
source regulations per_lbpCup�o nicipaLCode, Section 9.18.
Date 3/15/2017
I hereby affirm that I am exempt from the Contractor's License Law for one of the
following two reasons:
1. I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec.7044, Business & Professions Code)
2. I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec.7044, Business & Professions Code).
I hereby affirm under penalty of perjury one of the following three declarations:
1. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
z. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
3. I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the
Worker's Compensation laws of California. If, after making this certificate of
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
relating to building construction, and hereby authorize representatives of this city
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
Code, Section 9.18.
Date 3/15/2017
CONTRACTOR: PERMIT NO: B-2017-0426
BIGHAM SERVICES
INC
SANTA ROSA, CA
95404
DATE ISSUED: 03/15/2017
PHONE NO: (707) 545-1800
BUILDING PERMIT INFO:
X BLDG —ELECT _ PLUMB
X MECH X RESIDENTIAL _ COMMERCIAL
JOB DESCRIPTION:
REPLACE FURNACE AND A/C; DUCT REPLACEMENT (SAME
LOCATION)
Sq. Ft Floor Area: I Valuation: $22196.00
APN Number: Occupancy Type:
366 24 044
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS FROM LAST CALLED INSPECTION.
Issued by: Abby A ende
Date: 03/15/2017
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature ofApl
Date: 3/15/2017
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
the Health & Safety Code, Se ' 25505, 25 and 25534.
Owner or authorized agent: _
Date: 3/15/2017
CON CY
I hereby affirm that there is a construction lending agency for the performance
of work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Licensed
Professional
r
GENERAL PERMIT APPLICATION ROMP
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building9cupertino.org
I IPLUMBINCT N-11MAC'TTAMTC AT. nT.T
MISC
- ^ --
PROJECT ADDRESS1 k53 V
----- ---
1 -via
1 Pj,
! LJiv
7N# f
reLLfftilVDVVJ
044 4y
OWNER NAME 0 in D k
PHONE 0,8 _ 67+5t
MAIL
STREET ADDRESS c 1
6 S �,o )10 -
C TY, STAT ,, ZIP ^�
u �r A- 8301
FAX
CONTACT NAME KI
1
pgO 7d7� r-^ ��� `
`/ `✓'1 U
�L
STREET ADDRESS o
kl� W1 9111
C � E, ZIP
p
❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR R CONTRACTOR AGENT. ❑ ARCHTTE
T ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME
LICENSE NUMB!jMq I
LICENSE T
e
BUS. LIC # ;�yj'�
COMPANY NAME , I
' 6ar WhicA
�- `f
E-MAII
FAX
STREET ADDRES
a
j
CIT TAT ZIP
n 6k 15
D
P 7h 34 =1800
AR CHITECTIENGINEER NAME LICENSE NUMBER
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
USE OF RMIDUPLEX ❑ MULTI -FAMILY
B=ING: ❑ COMMERCIAL
PROSECT IN WILDLAND ❑ YES
URBAN INTERFACE AREA ❑ NO
PROJECT IN
FLOOD ZONE
Q YES
0 NO
IS THE BLDG AN ❑ YES
EICHLER HOME? ❑ NO
DESCRIPTION III LAC C _I
L►1« - a w e SEE I b
- nn
QVC 6
TOTAL VALUATION: 2 /
RECEIVED BY:
By my signature below, I certify to each of the I am the property owner or authorized agent to act on the property
application and the information I have Ided is torr t. I hav the Description of Work and verify it is accurate.I
ordinances and state laws relating t ld-Z cons b . authori re r ves of Cupertino to enter the above-
Signature of Applicant/Agent: e Date: J—
owne s behalf. I have read this
agree to comply with all applicable local
enti_fiI ed property for inspection purposes.
UPPLEMEN FORMATION REQUIRED
OFFICE USE ONLY
w
❑ OVER-THE-COUNTER
❑ EXPRESS
U
❑ STANDARD
v
❑ LARGE -
A
❑ MAJOR
MEPMiscApp_2011.doc revised 06121/11
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC)
,Project Name:
1658 S. Stelling Rd. I Date Prepared:
CF1R-ALT 02-E
(Page 1 of 3)
2017-03-13
A. General Information
CF113-ALT 02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT 02 document for each dwelling unit.
01
Project Name
1658 S.,Stelling Rd.
02, ,
Date Prepared
2017-03-13
03
Project Location
1658 S. Stelling Rd.
04
Building Type
Single family
05
CA City
Cupertino
06.
Dwelling Unit Name
1658 S. Stelling Rd.
07
Zip Code
95014
08
Dwelling Unit Conditioned
1758
Floor Area (ft2)
SC System
SC System
CFA served
system a
refrigerant
Number of Space
Installing
09
Climate Zone
4
10
Conditioning (SC) Systems in
1
ducted
containing
system
more than 40
this Dwelling Unit:
entirely new
B. Space Conditioning (SC) System Information
01
02
03
04
051
06
:-r_'
08
"09
10
Is the SGµ
listalling a
SC System
SC System
CFA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
Altered space
System 1
Location 1
1758
Yes
Yes
Yes
Yes
No
No
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 217-A020080530A-000-000-0000000-0000 Registration Date/Time: 2017-03-13 20:43:44 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-13 20:43:40
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1, 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: �7
Schaff, Kevin
CJ��%�'
Company:
Signature Date:
BIGHAM SERVICES INC dba ONE HOUR HEATING & A/C
2017-03-13 20:43:44
Address:
CEA/ HERS Certification Identification (if applicable):
1400 PETALUMA HILL RD
740999
City/State/Zip:
Phone:
SANTA ROSA CA 95404
707-545-1800
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the buildingdesignor system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. '+
4. The building design features or system design features identified.,this Certiflcate bf d6mbliance are'consisteAwith the 6` ormattop provided on other-appl cablis compliance documents, worksheets,
i�, rt
calculations, plans and specifications submitted to the enforcementi agency for,approval`$wlf� this building permit apollicatign.
5. I will ensure that a registered copy of this Certificate of Giornpliance shall berma'de�ayallable wlth ,the buildi.ngpermit(s),,issued for,the dildlog and made available to theienforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Colnpliance,ls,requjred to be,included with the,documentation.,therbuilder proyides tq.the building owner at occupancy.
Responsible Designer Name: � } „1i
;; 1 1 : J +-
Responsible De§igrier Signature: , - �
`�
Schaff, Kevin
�/� C��- //
Company:
Date Signed:
BIGHAM SERVICES INC dba ONE HOUR HEATING & A/C
2017-03-13 20:43:44
Address:
License:
1400 PETALUMA HILL RD
740999
City/State/Zip:
Phone:
SANTA ROSA CA 95404
707-545-1800
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider
responsibility for the accuracy of the information.
Registration Number: 217-A020080530A-000-000-0000000-0000
Registration Date/Time:
2017-03-13 20:43:44
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-13 20:43:40
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
All new11
new
System 1
furnace
heating
AFUE
96
en ra split
AC
cooling
SEER
16
Setback
Greater than
R-6
components
components
40 feet
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF313-MCH-20-11 - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <= 15% or <= 10% leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF311-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH 20 Duct Leakage Testing requirements
Heating -only systems and Air Handler Furnace changes do not require verificat!6W Air Floyy MCH' 23?.,Iot"Refrigerant Charge MCH 25 N
Y`
Existing duct systems constructed, insulated or sealed with asbesto, ,;are exem�C'from MCH=2tl DuCt;Len1kage Testin"g,require�renfs.
E. Entirely New or Complete Replacement Duct,81yftern, with or without Equ piment Changeout (Sections 150 2(b)1Dua and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 217-A020080530A-000-000-0000000-0000 Registration Date/Time: 2017-03-13 20:43:44 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-13 20:43:40
Schema Version: rev 10/16
w
SMOKE / CARBON MONOXIDE ALARMS
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 ¢ FAX (408) 777-3333 • building(-cupertino.org
PERMIT CANNOT BE FINALED -UNTIL THIS CERTIFICATE HAS BEEN
COMPLETED, Sffi Ll2, AND ET
�-�%HUD TO THE BUILDING DIVISION
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2016 CRC Section R314, R315, 2016 CBC Sections 420.6 and 907.2.11.2- where no interior access
for inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314, 8315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or
Carbon Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s) - (Smoke alarms shall not be located within 3 feet of bathroom door)
X
X
On every level of a dwelling unit including basements and habitable attics
X
X
Within each sleeping room
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. 'Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and, California Residential Codes. The alarms specified below have been tested and are operational, as of the
date signed below.
Address:
Permit No, P 201--) -041'&
Specify Number of Alarms: # Smoke Alarms: FT -1 # Carbon Monoxide Detectors:
1 have read and agree to comply with the terms and conditions of this statement
Owner (or Owner Agent's) Name:
�t
Signature ... ............... ................................................................... Date: 32y!i
Contractor Na e:
Signature...................................................................... Lic.#........................................ Date:...................
Smoke and CO form.doc revised 0111012017
GUPERTtN
Owner Naive
Address
MATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
-3333 • buildingna.cupertino.ora
1. Is your real property a registered historical. site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
Ga"'No Go to Question 2. ,
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation'of water -conserving plumbing fixtures is not technically feasible?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to, the Building Division.
Skip the rest of the form and sign bottom of form.
F-� 'No Go to Question 3.
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
KNo Go to Question 4.
4. Is your real property built and available for use or occupancy on or before January 1, 1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 110 1. 1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. .
Q Yes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
Pl ase check ONE of the following:
My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
property undergoes alterations or improvements).
❑ My property is a multifamily residential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout,the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless ofwhether property undergoes alterations or improvements).
I, as the owner or owner's agent of this properly, certify under penalty of perjury that non-compliant plumbing fixtures will be
replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1
through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's
installation requirements, and that the water -conserving -plumbing fixtures comply with the requirements as indicated in the
table on the following page.
Owner or Owner Agent's Signature: U �NWD Date: i �-Z4 q7
Upon completing and signing this CeitificaflcJplease return it to the Building Division in order to final your building pen -nit.
SB407 2015. doc revised 08126/15