Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2017-0481
CITY OF CUPERTINO BUILDING PERMIT BUILDINGADDRESS: 10332 SCENIC CIR CUPERTINO, CA 95014-2766 (357 07 006) CONTRACTOR: VITALLY ONISKO PERMIT NO: B-2017-0481 SACRAMENTO, CA 95842 OWNER'S NAME: MANICKAM OLAGAPPAN AND TRILOCHANA DATE ISSUED: 03/24/2017 OWNER'S PHONE: 408-772-2848 PHONE NO: (916) 640-6801 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class 5 Lic. #986930 Contractor VITALLY ONISKO Date 09/30/2017 X_ BLDG —ELECT _PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing — MECH X RESIDENTIAL _ COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: I hereby affirm under penalty of perjury one of the following two declarations: REMODEL (E) MASTER BATH 105 S.F. (LIKE FOR LIKE) 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $8500.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize 357 07 006 representatives of this city to enter upon the above mentioned properly for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point WITHIN 180 DAYS OF PERMIT UANCE OR source regulations p e Cu rtino Municipal Code, Section 9.18. 180 DAYS FRO SPECTION. Signature'` ^� Date 03/24/2017 ued by: ME Date: 03/24/2017 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Scc.7044, Business & Professions Code) z. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 03/24/2017 I hereby affirm under penalty of perjury one of the following three declarations:ALL 1. I have and will maintain a Certificate of Consent to self insure for Worker's ROOF COVERINGS TO BE CLASS "A" OR BETTER Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous Worker's Compensation laws of California. If, after making this certificate of air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agent:'/ APPLICANT APPLICANT CERTIFICATION Date: 03/24/2017 I certify that I have read this application and state that the above information is CONSTRU40N LENDING AGENCY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Signature Date 03/24/2017 Licensed Professional El NEW CONSTRUCTION CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildin-q,@cupertino.org D ADDITION I - 1 -ALTERATION / Ti n RP.VTCT(-1N / rIFFFRRFII nurr:IINTAT-PPPTIaTT 44 PR f E T fff � '!vI C a� APN # `r'� — , 04YNE ME PH NE E-MAIL STREET ADDRESS 10'3 Z � C Y, STATE, ZIP �f FAX CONTACT NMJE S / PHONE (� /o_ 3 e2 =3o E-MAIL STREE�TADDRESS C� % (/ f3 !�''�S S U ZIP �c q / ^ L ✓ry fav'"g G� I Z/J FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT G—CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHIPECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT COPdTRACTT A. fE � � LICENS R� 3 LICENSE�gE BUS. LIC # �C COMPANY NAME E-MAIL FAX STREET �� p �^�7 LFC PONE �7s� sZSL/�n 1/li A� �� c£ / ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COIAP.AN'Y NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP — I PHONL'• �A� ,� DESCRIPTION OF WORK / r^ Yip ovrny e 'i �C� .!IeA- T. file Ile v�7 ko W Q y l3 %N C?-- -S P° 0/_1_ _�� W 7S �r%, M f r� � i�-V b EXISTING USE PROPOSED USE CONSTR TYPE 9#STORIES USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN REMODEL AREA tom' REMODEL AREA OTHER REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH # DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY ❑ YES BEING ADDED? ❑ NO ADDITION? FIND - PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN CEIVED BY: TOTAL VALUATION: PLANNING APPL # []NO PLANNING APPROVAL LETTER EICHLFR 0 F By my signature below, I certify to each of the following: I am the property owner or alr9orized agent tclaeo. th roperty owner IL I have read this application and the information i have provided is co rre t. I have read the Description of Workzt eri ccurate. I agree to comply l ap licable local ordinances and state laws relating to buildin ons tion. I authorize representatives of Cupertino to enter the above -identified property for inspection ses. 7 Date: "—� -/7 Signature of Applicant/Agent: SUPPLEMENT ORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP ❑ OVER-THE-COUNTER ❑ BUILDING PLAN REVIEW New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDAR_ D ❑ PUBLICwORKS form if any Hazardous Materials are being used as part of this project. 0 LARGE © FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_2011.doc revised 06121/11 Assessor's Parcel Number: Name of Owner. , .ri _ e-= iyy _ Contact Person: _L,� Gw-N _ _ Phone: _. P.,roJect Address:,,v;� _�:_6=L Scope of Work: _!/`a 4 -Zai ✓su. ..-. �r _ N.c. " /.tl�r a� c r -1� � Applicable Code: 2016 California Residential Code (CRC) 2016 California Plumbing Code.(CPC)-- 2016 Califo'nia Mechanical Code (CMC) _ 2016 California Electrical Code (CEC) - 2016 California Energy Code (CEnerC) - - - 2016 California Green Building Standards Code (GRN) PLUMBING: Allmil Y,, inch or more in diameter and all hot water pikes associated with a recirculation system must be insulates with min. 1 -Inch thick locilaton. Existing Inaccessible piping does not require insulation [CEni 150.00)2). _ - - • Water closets shall not exceed 1.28 gallons per flush, showerheade shall not exceed 2.D GPM and new lavatory faucets shall not exceed 1.2 GPM at 60 PSI. [CPC - 407.2, 408.2 & 411.2) -- Water closet and bidets require a minimum 15 inches of clearance from the center line of the bowl to each side, end 24 inches of clearance from the front edge of the bowl [CPC 401 • Lavatory sinks require minimum of 24 inches front clearance [CPC 402,5] • Showers require a minimum 2 inch drains and trap ]CPC Table 702. 1], • All shower compartments shall have a minimum finished interior of 1024 square Inches and shall be capable of encompassing a 30 Inch diameter circle [CPC 408.6].The curb may encroach on these size requirements, All surfaces shall be wa:efproof up to 72 Inches above the drain Inlet [CRC R307.2], Thresholds shall be of sufficient math to accommodate a minimum 22 inch clear egress opening from the shower [CPC 401 • Safety glass (tempered or laminated) is required for al! glass shover doors and partitions and for windows in walls facing the tub or shower and located less than 60 Inches above the standing surface of the tubishower and within 60 Inches horizonta',ly [CRC R308.4,1 &5], • 'fhe maximum water temperature to a shower or tub/shower combination is 120F. The water heater thermostat cannot be used as the control for this temperature. Valves shall provide scald and thermal shock protection, and be pressure -balanced, thermostatic, or combination pressure-balanced/thermostatic mixing !n accordance with ABBE 1316 or ASME At 12, 18.1/CSA B125.1. [CPC 408.3] CUPERTINO j J 9uill Denartment MAR 2 y 2W7 REVIEVVEt) FUR. CODE COMPLIANCE i' evleweQ By �— AA A-<_'T7ey2, EXISTING BATHROOM FLOOR PLAN MECHAtJICAL • Mechanical ventilation is required in all bathrooms with tubs or showers. The fan must move a minimum 50 CFM of air and be separately switched .from the lighting. Fans that operate continuously can be 20 CFM. The duct must terminate omthe exterior not less than 3 feet from openings into the building [CMC 502.2.11. • Baths with no tub or shower (half baths) do not require mechanical ventilation if they are provided with a window at least 3 sq. ft. half of which Is operable ICRC R303.3). ELECTRICAL. - All ostalled lighting shall be high efficacy, tCE 0150 p(k}4.A] -. _. • At least one light shall be controlled by avaconey sensor (a irm nual on, aitomatic-off occupancy sensor). [CE—C 150.0(k)2A] • All receptacle outbats in bathrooms shall be GFCI,prptected ICEC 210.BA1], - All receptacle outlet in bathreo shall be Campo .:Islan(jCEC 406.'12A]. f' - When a bathtub orshewer stall is In an area not technically considered is bathroom (by the definitions In the electrical code), receptacles within 6 fl, of the - tub/shower stall must be GFCI- protected. [CEC210,8A9], - • A receptacle outlet is required within 3 feet of each wash basin location. It may be or the wall, or an ad;acent pardhop or on the face or side of the cabinet not more than 12 Inches below the top of the basin [CEC 210.52D]. - Receptacles cannot be face -up in a vanity surface: listed pop-up receptacles are allowed [CEC 406.5E & 210,52D). - • ' A minimum of -o Re 20 -amp -circuit Is required for the [eceptacles In the b6throorn(s). This eircuit can have no other outlets, including. lights [CEC 2 10. 11 C3] If a - 20 -amp cii it serves onlynhe bathroom, lights and fans can be or the same circuit w¢h'jbe receptacles in that bathroom [CEC 210,11 C3 axcapt!on]. • H ydro-massage,tuts, require an individual -(dedicated) branch circuit and readily accessible GPCI protection [CEC 680,71], An access door is required and must be large enough to remove the motor and pump. Cord -connected equipment must have the receptacle facing the opening and be no mere than one fact behind file access hatch [CEC 660.73]. • Recessed'. light fixtures in shower enclosures must be listed for a damp or wet location [CEC 41 D.1CA] - - - • Pendant light fixtures, track lights, and paddle fans shall not be Installed lower than 8 feet above the Flood -level rim of a tub, Including the area 3 feet past the edge of the tub ICEC 410.10D). - • Electrical panels shall not be installed in bathrooms (CEC 240.24E. • Switches and receptacles are not allowed In bathtub or shower spaces [CEC 404.4C & 406.90). 1Z0" 0 F F Cti", ��� rLOFi,tr(.]r :';SRT tENT I j3 U. I L D 17,r�A1 c„djxl� q "n it h 5'd L �r 71 �i n2r 1 Jlll ' he`d to U� ”