14040087CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10438 N STELLING RD
CONTRACTOR: JOSHUA
PERMIT NO: 14040087
CONSTRUCTION & REMODELING
OWNER'S NAME: HONGQI HU
10613 GASCOIGNE DR
DATE ISSUED: 06/30/2014
OWNER'S PHONE: 4087253692
CUPERTINO, CA 95014
PHONE NO: (408) 725-3692
❑ LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑
CONSTRUCT (N) 2 STORY SFD (3,259 S.F.) WITH
License Class_ Lic. 0-21
ATTACHED 2 CAR GARAGE (431 S.F.) (ATTACHED
a ��
GRANNY
Contractor ate
wl
UNIT BP# 14040088)(DEMO PERMIT # 14060104)
1 hereby affirm that am licensed;QWSi ori [Chapter 9
(commencing with Section 7000) of Division 3 of the Business & ProfessionsreV°
on #I ise layout of interior wall, add (2) skylights- issd
Code and that my license is in full force and effect.
cl/ 014
1 hereby affirm under penalty of perjury one of the following two decl
I have and will maintain a certificate of consent to self -insure for W
Compensation, as provided for by Section 3700 of the Labor Code,
Sq. Ft Floor Area:
Valuation: $400000
performance of the work for which this permit is issued.
1 have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
APN Number: 32630096.00
Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
180 DAYS FR ST CALLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
I p
granting of this permit. Additionally, the applicant understands and will comply
Issued by: Date:
with all non -point source regulations per the Cupertino Municipal Code, Section
9.18.
^�
Signature to �r ��
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
61
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
❑ OWNER -BUILDER DECLARATION
Signature of Applicant: Date:
1 hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
I, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
1, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(a) should 1 store or handle hazardous
I have and will maintain a Certificate of Consent to self -insure for Worker's
material. Additionally, should I use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District 1
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & Safety Code, Sections 25505, 25533, and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this/
Owner or authorized agent: Date: /
permit is issued.
-
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, atter making this certificate of exemption, I
CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
ARCHITECT'S DECLARATION
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
1 understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18,
Signature Date
CUPERTINO
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building cDcupertino.org
❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI [Z REVISION /DEFERRED ORIGINAL PERMIT #
PROJECT ADDRESS A / , I
APN k
OWNER NAME
PHONE � _ /. _
EMAIL
STREET ADDRESS
CITY, STATE, ZIP
CONTACT NAME
PHONE
E-MAIL
STREET ADDRESS
CITY, STATE, ZIP
FAX
❑ OWNER ❑ O,kT'ER-BUILDErR ❑ OWT'ER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME D /� ( L j / i
'Y ]
LICENSE NUMBER I
(�
,yENGINEER
LICENSE TYPE K
✓
BUS. LIC k
COMPANYNAME f E-MAIL
FAX
STREETADDRESS /��� % 1� CITY,fTATE,ZIP /9 ` _ /�,p bl�/ /i
(.may l lL
PHONE
ARCHITECT/ENGINEER NAME
LICENSE NUMBER
BUS. LIC k
COMPANYNAMEZ;' _olio CP J 1.
(l (( C
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
DESCRIPTION OF WORK 1 �`
/d^ Kd L
1A Lt �. ei �I' pi ram' oar Ov'a'ie� aA � r o
dtnc�i r h,l.1v�• r I f
of r'�G Thr.
EXISTING USE
PROPOSED USE CONSTR
TYPE
k STORIES
USE
TYPE OCC.
SQ.FT.
VALUATION (S)
EXISTG
NEW FLOOR
DEMO
TOTAL
AREA
AREA
AREA
NEI- AREA
BATHROOM
KITCHEN
OTHER
REMODEL AREA
REMODEL AREA
REMODEL AREA
PORCH AREA
DECK AREA
TOTAL DECK/PORCH AREA
GARAGE AREA: DETACH
❑ ATTACH
k DWELLING UMTS:
IS A SECOND UNrr ❑ YES
SECOND STORY ❑ YES
....—
BEING ADDED? I] NO
ADDITION? []NO
PRE -APPLICATION [:)YES IF YES, PROVIDE COPY OF
PLANNING APPL k NO PLANNING APPROVAL LETTER
IS THE BLDG AN I] YESRECEIVED
EICHLER HOME? NO
TiY, r
'
TOTAL V.AQ_ TION:
❑
❑
i
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes.
` Date: %
Signature of ApplicanUAgent: !
SUPPLEMENTAL INF 4ATION REQUIRED
PLO cliczxPE,
ROUTING SLIP'
ouER ��>+-coaNTER
uYi✓DINc rtaN xt.��w
New SFD or Multifamily dwellings: Apply for demolition permit for
existing building(s). Demolition permit Is required prior to Issuance of buildi
t
,.
permit for new building.
p g•
❑�
� EXPRESS�f r �
L1 PLANNING P&AN REVIEW t
_ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
CI''sTArpAiiD
❑ rvBLlc`woRxs '
form if any Hazardous Materials are being used as part ofthis project.-~
❑,
Copy of Planning Approval Letter or Meeting with Planning prior to
LARGE
r�
PIR$ DEPS'
SAAITARY
submittal of Building Permit application.
MAJOR
SEWER DISTRICT , =
y�
❑
ENVIRONkENTALIiEALTAr,
BldgApp 2011.doc revised 06/21/11
CITY OF CUPERTINOFM_7
FEE ESTIMATOR BUILDING DIVISION
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
Diclrirt etc )- These fees are hated on flip. nreliminary informntion availahle and are only an estimate_ Contact the Dent for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Eff 711//3)
ADDRESS: 10438 n stelling rd
DATE: 12/17/2014
REVIEWED BY: Mendez
APN:
BP#:
"VALUATION: j$1,000
"PERMIT TYPE: Building Permit
PLAN CHECK TYPE: Addition
PRIMARY SFD or Duplex
USE:
PENTAMATION
PERMIT TYPE:
WORK
revision #1- revise layout of interior wall add 2 skylights- issd otc 12/18/2014
SCOPE
PME Plan Check:
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
Diclrirt etc )- These fees are hated on flip. nreliminary informntion availahle and are only an estimate_ Contact the Dent for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Eff 711//3)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$0.00
Select a Misc Bldg/Structure
or Element of a Building
Suppl. PC Fee: E) Reg. ® OT
0.0 1
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$0.00
SuppL Insp. Fee -.0 Reg.
Q OT
1 0.0
1 hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
Work Without Permit? 0 Yes (j) No
$0.00
Advanced Planning Fee:
$0.00
Select a Non -Residential
Building or Structure
E)
Strom Motion Fee.
iBSEISMICR
$0.50
F-1-1 #
$859.00
Revisions
IREVSFDW1 SFDWL
Bldg Stds Commission Fee: IBCBSC
$1.00
SUBTOTALS:
$1.50
$859.00
TOTAL FEE:
F $860.50
Revised: 10/01/2014
CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10438 N STELLING RD
CONTRACTOR: JOSHUA
PERMIT NO: 14040087
CONSTRUCTION & REMODELING
OWNER'S NAME: HONGQI HU
10613 GASCOIGNE DR
DATE ISSUED: 06/30/2014
OWNER'S PHONE: 4087253692
CUPERTINO, CA 95014
PHONE NO: (408) 725-3692
LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑
V26.r
CONSTRUCT (N) 2 STORY SFD (3,259 S.F.) WITH
License Class__,_.__ Lic. N �9
ATTACHED 2 CAR GARAGE (431 S.F.) (ATTACHED
6/
NY
Contractor i !t , Date O
UNIT BP# 14040088)(DEMO PERMIT # 14060104)
I hereby affirm that I am licen under the pr visions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
1 hereby affirm under penalty of perjury one of the following two declarations:
1 have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
Sq. Ft Floor Area:
Valuation: $400000
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
APN Number: 32630096.00
Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
I certify that l have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
WITHIN 180 D IT ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
180 � A7LLED INSPECTION.
indemnifyand keepharmless the Cit of Cupertino against liabilities,
Y p e judgments,
costs, and expenses which may accrue against said Cit in consequence of the
n
p Y g Y q
Date:
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
9.18.
RE -ROOFS:
Signature Date
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, 1 agree to remove all new materials for
inspection.
❑ OWNER -BUILDER DECLARATION
Signature of Applicant: Date:
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" 012 BETTER
I, as owner of the property; or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS NIATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(x) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self -insure for Worker's
material. Additionally, should 1 use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District 1
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
I have and will maintain Worker's Compensation insurance, as provided for by
the Health & Safety Code, Sections 25505, 25533, and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this
is issued.
Owner or authorized agent: Date: Q
permit
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code, I must
l hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTI FICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
ARCHITECT'S DECLARATION
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
I understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18.
Signature Date
CVPER-FINN
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 \k�
(408) 777-3228 • FAX (408) 777-3333 • buildinp(aa)cupertino.org,
® NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/T1 ❑ REVISION /DEFERRED ORIGINAL PERMT II
PROJECT ADDRESS -7 10438 STELLING ROAD
APNa 326-30-096
OWNERNAME HONGQI HU
PHONE 408.725.3692
E-MAIL `T�r///I j04 ((([ vI
C
STREET ADDRESS 10613 GASCOIGNE DR
CITY. STATE, ZIP CUPERTINO CA 95014
FAX
CONTACT NAME FRANK L. HO
PHONE 408.892.5020 7
E-MAIL FRANKLHO@yahoo.com
STREET ADDRESS 12480 Saratoga Avenue
CITY, STATE, ZIP Saratoga, CA 95070
FAX
❑ OWNER ❑ OW'N'ER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT 12 ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME TBD
LICENSE NUMBER
LICENSE TYPE
BUS. LIC d
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ARCHITECT/ENGINEER NAME FRANK HO
LICENSE NUMBER 029889
BUS. LIC d
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS 12480 SARATOGA AVE
CITY, STATE, ZIP Saratoga CA 95070
PHONE 408.892.5020
DESCRIPTION OFwoRK New 2 stories house with 4 bedrooms, 4.5 bathrooms,
AAAttJ �'sJEti l�. Also include 2 cars garage. Total living area is 3259- Total garage is 431sf
EXISTING USE
PROPOSED USE CONSTR.
TYPE
a STORIES
SFR
SFR
VB
2
USE
TYPE
OCC.
SQ.FT.
VALUATION (S)
EXISTAREAL 1 ,246
NEW FAREA LOOR
AREADEM
1,246
NETAAREA
V I j
PL
�j2 GC1
Y00� 000
BATHROOM
REMODEL AREA
KITCHEN
REMODEL AREA
OTHER
REMODEL AREA
PORCH AREA
DECK AREA
TOTAL DECK/PORCH AREA
GARAGE AREA LJ DETACH
3b`j Za
411
431 ®ATTACH
N DWELLING UNITS.
IS A SECOND UNIT ® YES
SECOND STORY ® YES
2
BEING ADDED? ❑NO
ADDITION? NO
PR&APPLICATION NI YES IF YES, PROVIDE COPY OF
IS THE BLDG AN ❑ YESEl
VED BY:
TOTAL VALUATION:
PLANNG APPL N ❑ NO PLANNING APPROVAL LETTER
BJ
EICHLER HOME? ® NO
r
//YL//'.f���p' (�,v (&
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorise r presentatives of Cupertino to enter the above -identified property for inspection purposes.
Signature of ApplicantlAgent: Da
SUPPLEMENTAL INFORMA N REQUIRED
PLAN CHECK TYPE
ROUTING SLIP
❑ OVER-'I'9E-COUNTER
❑ BUILDING PLAN REVIEW
_ New SFD or Multifamily dwellings: Apply for demolition permit for
existing building(s). Demolition permit is required prior to issuance of building
permit for new building.
❑ EXPRESS
❑ PLANNING PLAN REVIEW
_ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
❑ STANDARD
❑ PUBLIC WORKS
form if any Hazardous Materials are being used as part of this project.
❑ LARGE
❑ FIRE DEPT
_ Copy of Planning Approval Letter or Meeting with Planning prior to
El
El SANITARY SEWER DISTRICTsubmittal
of Building Permit application.
MAJOR
❑ ENVIRONMENTAL HEALTH
BldgApp 2011.doc revised 06/21/11
oo v)
CITY OF CUPERTINO
FEE ESTIMATOR - BUILDING DIVISION
OCCUPANCY TYPE:
10438 N STELLING RD DATE: 04/15/2014
REVIEWED BY: MELISSA
imADDRESS:
APN: 326 30 096 BP#: ���
VALUATION: $400,000
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE: New Construction
PRIMARY
USE: SFD or Duplex
2nd Unit? Yes No
TiPENTAMATION
PERMIT TYPE: 1 R3SFD
WORK
CONSTRUCT N 2 STORY SFD (3,259 S.F. WITH ATTACHED 2 CAR GARAGE 431 S.F.
SCOPE
II-B,III-B,IV,V-B
OCCUPANCY TYPE:
TYPE OF
CONSTR.
FLR AREA
s.f.
PC FEES
PC FEE ID
BP FEES
BP FEE ID
R-3 (Custom)
II-B,III-B,IV,V-B
3,259
$3,037.08
IR3PLNCK $3,062.92
IR3INSP
U (Private Gar/Ag Bldg)
II-B,III-B,IV,V-B
431
$0.00
IUIPLNCK
$1,252.00
IUIINSP
Permit Fee:
$4,314.92
Suppl. Insp. Fee:Q Reg.
Q OT
0,0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
TOTALS:
3,690
$3,037.08
$4,314.92
Construction Tax: IBCONST4XR
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
ni.ctrict_ ote 1_ Those fee_c are ha.sed an the nreliminary information availahle and are oniv an estimate Contact the Dent for addn'I info.
FEE ITEMS (Fee Resolution 11-053 Ef 7/1/131
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$3,037.08
Select a Misc Bldg/Structure
or Element of a Building
Suppl. PC Fee: 0 Reg. 0 OT
0.0
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$4,314.92
Suppl. Insp. Fee:Q Reg.
Q OT
0,0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
Construction Tax: IBCONST4XR
1
# new
units
$659.99
G
Work Without Permit? Yes (2) No
$0.00
Advanced Planning Fee:
IPLLONGR
$516.60
Select a Non -Residential
Building or Structure
d
i
Strong Motion Fee:
IBSEISMICR
$40.00
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$16.00
SUBTOTALS:
$8,584.59
$0.00, TOTAL FEE:
$8,584.59
Revised: 04/01/2014
4
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
STELLING RESIDENCE
10438 N. STELLING ROAD
CUPERTINO, CA 95014
Project Designer:
STUDIO 61 ARCHITECTS INC
12480 SARATOGA AU
SARATOGA, CA 95 V " ,,
408.892.5020
RECEIVED
Wn Report Prepared by:
MAY 2 7 2014 STUDIO 61 ARCHITECTS INC
Job Number:
1338
Date:
5/23/2014
mM
yyyy ���wU jj��
wrvm w% fI,
p'm arX ^{� e mrci.
IJ�ti 4 X�rm;;h�
rnx tlG
Nwwm�°�'"0rw'�fi
ygm✓mni�;mrmn'+��
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number: 5750 Run Code: 2 0 1 4-05-23 70 2:32:27 ID: 1338 1
TABLE OF CONTENTS I
Cover Page
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 9
HVAC System Heating and Cooling Loads Summary 12
Room Load Summary 15
Room Heating Peak Loads 18
Room Cooling Peak Loads 21
5.1 by EnergySoft
ID: 1338
User Number: 5750
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
STELLING RESIDENCE
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/23/2014
Project Address
10438 N. STELLING ROAD CUPERTIN
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area
3,784
Addition
n/a
# of Stories
2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features (see Part 2 of 5) Status
Floor Wood Framed w/Crawl Space
R-30 3,784 New
Wall Wood Framed
R-13 2,974 New
Door Opaque Door
None 94 New
Roof Wood Framed Attic
R-38 1,755 Radiant Barrier Venting New
FENESTRATION U- Exterior
Orientation Area(e) Factor SHGC Overhang Sidefins Shades Status
Front (lAq 177.0 0.390
0.37 none none Bug Screen New
Left (N) 176.0 0.390
0.37 none none Bug Screen New
Rear (E) 200.0 0.390
0.37 none none Bug Screen New
Right (S) 155.0 0.390
0.37 none none Bug Screen New
Skylight 9.0 0.370
0.29 none none None New
Skylight 9.0 0.370
0.29 none none None New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Gravity Wall Furnace 67% AFUE
No Cooling 13.0 SEER Setback New
1 Gravity Wall Furnace 67% AFUE
No Cooling 13.0 SEER Setback New
1 Gravity Wall Furnace 67% AFUE
No Cooling 13.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC FOR FIRST FLOOR Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
HVAC FOR SECOND FLO Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
FURNACE FOR SECONDr Ductless / No Fan
Ductless n/a n/a New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Instant Gas 0
0.84 Kitchen Pipe Ins New
1 Instant Gas 0
0.84 Kitchen Pipe Ins New
EnergyPro 5.1 by EnergySoft User Number.- 5750
RunCode: 201405-23T02:32:27 ID: 1338
Page 3 of 23
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
STELLING RESIDENCE
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/23/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The HVAC System Williams 2519622 does not include a cooling system, field verification is not necessary.
The HVAC System Williams 2519622 does not include a cooling system, field verification is not necessary.
The HVAC System Milliams 2519622 does not include a cooling system, field verification is not necessary.
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
The Roof R-38 Roof Attic includes an Airgap below Roofing 1/150 Vent Area 50% of Vents Located High requires verification.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by Ene Soft User Number: 5750 Run Code: 20 1 4-0 5-23 70 2:32:27 ID: 1338 Page 4 of 23
PERFORMANCE CERI'IFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
STELLING RESIDENCE
D Multi Family ❑ Existing+ Addition/Alteration 1512312014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ftp- r
Space Heating 25.15 24.84 0.31
Space Cooling 6.78 6.48 0.30
Fans 4.69 4.36 0.33
Domestic Hot Water 18.34 12.72 5.62
Pumps 0.00 0.00 0.00
Totals 54.96 48.41 6.56
Percent Better Than Standard: 11.9
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (w) 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 2.00 (vu 1,018 177
Fuel Available at Site: Natural Gas (N) 952 176
Raised Floor Area: 3,784 (E) 805 200
Slab on Grade Area: 0 (S) 1,001 155
Average Ceiling Height: 10.1 Roof 1,773 18
Fenestration Average U -Factor: 0.39 TOTAL: 726
Average SHGC: 0.37 Fenestration/CFA Ratio: 19.2
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company STUDIO 61 ARCHITECTS INC
5/23/2014
Address Name
City/State/ZipCity/State/Zip Phone Si ed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Despigner or Owner& Professions Code)
liner per gs iiness
Comany
Address 12480 SARA TOGA AVE Name FRANK LINH HO
City/State/Zip SARATOGA, CA 95070 Phone 408.892.5020 Signed License # Date
Ener Pro 5.1 by EnerqySoft User Number.' 5750 RunCode: 2014-05-23T02:32:27 ID: 1338 Page 5 of 23
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
STELLING RESIDENCE
Building Type m Single Family ❑ Addition Alone
❑ Multi Family CI Existing+ Addition/Alteration
Date
1512312014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Floor
2,046
0.028 R-30
0
180 New 4.4.1-A7
FIRST FLOOR LIVING
Wall
230
0.102 R-13
270
90 New 4.3.1-A3
FIRST FLOOR LIVING
Door
70
0.500 None
270
90 New 4.5.1-A4
FIRST FLOOR LIVING
Wall
377
0.102 R-13
0
90 New 4.3.1-A3
FIRST FLOOR LIVING
Wall
88
0.102 R-13
90
90 New 4.3.1-A3
FIRST FLOOR LIVING
Wall
295
0.102 R-13
180
90 New 14.3.1-A3
FIRST FLOOR LIVING
Roof
299
0.025 R-38
90
18 New 4.2.1-A21
FIRST FLOOR LIVING
Floor
1,213
0.028 R-30
0
180 New 4.4.1-A7
SECOND FLOOR LIVING
Wall
281
0.102 R-13
270
90 New 4.3.1-A3
SECOND FLOOR LIVING
Wall
317
0.102 R-13
0
90 New 4.3.1-A3
SECOND FLOOR LIVING
Wall
317
0.102 R-13
90
90 New 4.3.1-A3
SECOND FLOOR LIVING
Wall
325
0.102 R-13
180
90 New 4.3.1-A3
SECOND FLOOR LIVING
Roof
1,213
0.025 R-38
90
18 New 4.2.1-A21
SECOND FLOOR LIVING
Floor
525
0.028 R-30
0
180 New 4.4.1-A7
SECONDARY UNIT
Wall
260
0.102 R-13
270
90 New 4.3.1-A3
SECONDARY UNIT
Wall
58
0.102 R-13
0
90 New 4.3.1-A3
SECONDARY UNIT
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor SHGC
Azm Status
Glazing Type
Location/Comments
1
Mindow
115.0 0.390 NFRC 0.37 NFRC 270 New
Milgard Classic Low -E Vinyl
FIRST FLOOR LIVING
2
WIndow
42.0 0.390 NFRC 0.37 NFRC
0 New
Milgard Classic Low -E Vinyl
FIRST FLOOR LIVING
3
Window
126.0 0.390 NFRC 0.37 NFRC 90 New
Milgard Classic Low -E Vinyl
FIRST FLOOR LIVING
4
Mindow
85.0 0.390 NFRC 0.37 NFRC 180 New
Milgard Classic Low -E Vinyl
FIRST FLOOR LIVING
5
Skylight
9.0 0.370 NFRC 0.29 NFRC
90 New
Velux Comfort (75) Lowe2/Arg
FIRST FLOOR LIVING
6
IMndow
62.0 0.390 NFRC 0.37 NFRC 270 New
Milgard Classic Low -E Vinyl
SECOND FLOOR LIVING
7
Mindow
62.0 0.390 NFRC 0.37 NFRC 0 New
Milgard Classic Low -E Vinyl
SECOND FLOOR LIVING
8
Window
44.0 0.390 NFRC 0.37 NFRC 90 New
Milgard Classic Low -E Vinyl
SECOND FLOOR LIVING
9
Window
58.0 0.390 NFRC 0.37 NFRC 180 New
Milgard Classic Low -E Vinyl
SECOND FLOOR LIVING
10
Mindow
72.0 0.390 NFRC 0.37 NFRC
0 New
Milgard Classic Low -E Vinyl
SECONDARY UNIT
11
Mindow
30.0 0.390 NFRC 0.37 NFRC 90 New
Milgard Classic Low -E Vinyl
SECONDARY UNIT
12
Mindow
12.0 0.390 NFRC 0.37 NFRC
180 New
Milgard Classic Low -E Vinyl
SECONDARY UNIT
13
Skylight
9.0 0.370 NFRC 0.29 NFRC 90 New
Velux Comfort (75) Lowe2/Arg
SECONDARY UNIT
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
None
1.00
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
None
1.00
EnergyPro
5.1 by Ener Soft User Number: 5750
Run Code: 201405-23T02:32:27 ID: 1338
Page 6 of 23
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project NameBuilding
STELLING RESIDENCE
Type m Single Family
❑ Multi Family
❑ Addition Alone
❑ Existing+ Addition/Alteration
Date
5/23/2014
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4
Location/Comments
Door 24 0.500 None
0 90 New
4.5.1-A4
SECONDARY UNIT
wall 200 0.102 R-13
90 90 New
4.3.1-A3
SECONDARY UNIT
wall 226 0.102 R-13
180 90 New
4.3.1-A3
SECONDARY UNIT
Roo! 243 0.025 R-38
90 18 New
4.2.1-A21
SECONDARY UNIT
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC2
Azm Status Glazing Type
Location/Comments
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC H t Wd
Ove hang
Len H t LExt REA
Left Fin
Dist Len H t
Right Fin
Dist Len H t
EnergyPro 5.1 by EnergySoft User Number. 5750
Run Code: 2014-05-23T02:32:27
ID. 1338
Pae 7 of 23
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF-1 R
Project Name
STELLING RESIDENCE
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/23/2014
BUILDING ZONE INFORMATION
Floor Area
System Name Zone Name New Existing Altered Removed Volume
Year Built
HVAC FOR FIRST FLOOR FIRST FLOOR LIVING 2,046
21,892
HVAC FOR SECOND FLOOR SECOND FLOOR LIVING 1,213
11,160
FURNACE FOR SECONDARY FIRST FLOOR LIVING 525
5,250
Totals 3,784 0 0 0
HVAC SYSTEMS
System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type
Status
HVAC FOR FIRST FLOOR 1 Gravity Wall Fumac 67% AFUE No Cooling 13.0 SEER Setback
New
HVAC FOR SECOND FLOOR 1 Gravity Wall Furnace 67% AFUE No Cooling 13.0 SEER Setback
New
FURNACE FOR SECONDARY 1 Gravity Wall Furnace 67% AFUE No Cooling 13.0 SEER Setback
New
HVAC DISTRIBUTION
System Name
Heating
Cooling Duct Location
Duct
R-Value
Ducts
Tested? Status
HVAC FOR FIRST FLOOR Ducted
Ducted Attic, Ceiling Ins, vented
8.0
❑
New
HVAC FOR SECOND FLOOR Ducted
Ducted Attic, Ceiling Ins, vented
8.0
❑
New
FURNACE FOR SECONDARY Ductless/
No Fan
Ductless n/a
n/a
❑
New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Takagi T-K2
1
Instant Gas
Kitchen Pipe Ins
185,000
0
0.84
n/a
n/a
New
Takagi T-K2
1
Instant Gas
Kitchen Pipe Ins
185,000
0
0.84
n/a
n/a
New
MULTI-FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
Q
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum Outside
Buried
EnergyPro 5.1 by Ener Soft User Number: 5750 Run Code: 201405-23702:32:27 ID: 1338
Page 8 of 23
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
STELLING RESIDENCE
Date
5/23/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(')3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150(1)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Page 9 of 23
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
STELLING RESIDENCE
5/23/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of ILL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f12 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 5750 Run Code: 201405-23702:32:27 ID: 1338 Page 10 of 23
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name
Date
STELLING RESIDENCE
5/23/2014
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)11 : Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoR User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Page 11 of 23
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
STELLING RESIDENCE
Date
5/23/2014
System Name
HVAC FOR FIRST FLOOR
Floor Area
2,046
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 822
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG. PEAK
Heating System
Sensible
Latent
CFM Sensible
Output per System 25,000
17,295
1,028
414 20,676
Total Output Btuh 25,000
0
758
0
Output Btuh/s ft 12.2
509
Cooling System
0
Output per System 0
0
0 0 0
Total Output (Btuh) 0
3,070
-3,070
758
1,028 19,121
Total Output Tons 0.0
509
Total Output (Btuh/s ft) 0.0
Total Output s f /Ton 00
21,382
Air System
CFM perSystem
655
HVAC EQUIPMENT SELECTION
Airflow cfm
655
Williams 2519622 0
0
25,000
Airflow (cfm/s ft)
0.32
Airflow (cfm/Ton)
0.0
Outside Air (%)
0.0%
Total Adjusted System Output 0
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
25,000
Jan 1 AM
Outside Air (cfm/s ft 0.00
Note: values above given at ARI conditions 1
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
28 IF 67 IF
Outside Air Ar-
0 cfm Supply Fan
655 cfm
67 OF
70 IF 115 IF
0.
M
Heating Coil
G
114 IF
—
DOOM
68 IF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak
88 / 68 IF 75 / 62 IF 78 / 62 IF 55 / 54 OF
Outside Air
0 cfm Supply Fan Cooling Coil 55 / 54 OF
655 cfm
46.0% ROOM Ifl'
75/62°F 75/61 OF
EnergyPro 5.1 by EnergySoff User Number., 5750 Run Code: 201405-23T02:32:27 /D: 1338
Page 12 of 23
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
STELLING RESIDENCE
Date
5/23/2014
System Name
HVAC FOR SECOND FLOOR
Floor Area
1,213
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 473 9,985
Return Vented Lighting 0
Return Air Ducts 294
Return Fan 0
Ventilation 0 0
Supply Fan 3,070
Supply Air Ducts 294
TOTAL SYSTEM LOAD 13,642
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output per System 25,000
854 305
15,171
Total Output (Btuh) 25,000
Output Btuh/s ft 20.6
556
Cooling System
0
Output per System 0
0
0
0
Total Output (Btuh) 0
854
-3,070
Total Output (Tons) 0.0
556
Total Output (Btuh/s ft) 0.0
Total Output (s ft/Ton) 0.0
13,213
Air System
CFM per System
655
HVAC EQUIPMENT SELECTION
Airflow cfm
655
Williams 2519622 0
0
25,000
Airflow cfm/s ft)
0.54
Airflow cfm/Ton)
0.0
Outside Air %
00%
Total Adjusted System Output 0
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
25,000
Jan 1 AM
Outside Air (cfm/s ft) 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
28 IF 67 OF
Outside Air
AV -
0 cfm Supply Fan
655 cfm
67°F
72 OF 115 IF
Heating Coil
4 ETF] F --- 1.4
114 OF
-------------M
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
88 / 68 OF 75162 OF 80 / 63 OF 55 / 53 IF
Outside Air
0 cfm Supply I Fan
Cooling Coil 551 54 OF
655 cfm 46.1 % ROOM inl,
75/62°F 75/61 IF
EnergyPro 5.1 by EnergySoff User Number.' 5750 Run Code: 201405-23T02:32:27 ID: 1338
Page 13 of 23
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
STELLING RESIDENCE
Date
5/23/2014
System Name
FURNACE FOR SECONDARY UNIT
Floor Area
525
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 305
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
25,000
6,570
682
149
7,551
Total Output Btuh
25,000
0
Output (Btuh/s ft)
47.6
0
0
Cooling System
0
0
Output per System 0
0
0 0
0
Total Output Btuh) 0
3,070
682
-3,070
Total Output (Tons) 0.0
0
0
Total Output (Btuh/s ft) 0.0
Total Output s ft/Ton 0.0
9,640
4,481
Air System
CFM per System
655
HVAC EQUIPMENT SELECTION
Airflow cfm
655
Williams 2519622 0
0
25,000
Airflow (cfm/s ft)
1.25
Airflow (cfm/Ton)
0.0
Outside Air (%)
0.0%
Total Adjusted System Output 0
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
25,000
Jan 1 AM
Outside Air (cfm/s ft) 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
28 OF 68 OF
Outside Air
0 cfm Supply Fan
AL 655 cfm
68 OF
72 OF 115 OF
a
Heating Coil
115 IF
----
�ROOMh
68 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak)
88/68°F 75/61 IF 79/63°F 55/53°F
Outside Air Ar
0 cfm Supply Fan Cooling Coil 55 / 53 OF
655 cfm /��y�y� M
45.8 % ROOM
75 / 61 OF 75 / 61 IF
EnergyPro 5.1 by EnergySoff User Number: 5750 Run Code: 2014-05-23T02:32:27 ID: 1338
Page 14 of 23
ROOM LOAD SUMMARY
Project Name Date
STELLING RESIDENCE 5/23/2014
System Name Floor Area
HVAC FOR FIRST FLOOR 2,046
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM Sensible I Latent CFM Sensible Latent CFM I Sensible
FIRST FLOOR LIVING FIRST FLOOR LIVING 1 1 8221 17,2951 1,028 822 17,2951 1,028 4141 20,676
PAGE TOTAL
TOTAL
822 17,295
1,028
414
20,676
822 17,295
1,028
414
20,676
" Total includes ventilation load for zonal systems.
Ener Pro 5.1 by EnerqySoft User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Pae 15 of 23
ROOM LOAD SUMMARY
Project Name Date
STELLING RESIDENCE 5/23/2014
System Name Floor Area
HVAC FOR SECOND FLOOR 1,213
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM Sensible Latent CFM Sensible Latent CFM Sensible
SECOND FLOOR LIVING SECOND FLOOR LIVIN 1 1 473 9,985 854 473 9,985 854 305 15,171
PAGE TOTAL
TOTAL
Total includes ventilation load for zonal systems.
EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 2014-05-2 3 70 2:32:27
473
9,985 854
305
15,171
473
9,985 854
305
15,171
ID: 1338
[ROOM LOAD SUMMARY
STELLING RESIDENCE 5/23/2014
System Name Floor Area
FURNACE FOR SECONDARY UNIT 525
ROOM LOAD SLIMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent I CFM Sensible
SECONDARY UNIT FIRST FLOOR LIVING 1 305 6,570 682 305 6,570 682 149 7,551
PAGE TOTAL
TOTAL'
Total includes ventilation load for zonal
305
6,570 682
149
7,551
305
6,570 682
149
7,551
EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Page 17 of 23
ROOM HEATING PEAK LOADS
Project Name
STELLING RESIDENCE
Date
5/23/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name FIRST FLOOR LIVING
Floor Area 2,046.0 ft2
Indoor Dry Bulb Temperature 68 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 28 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
Btu/hr
R-30 Floor Crawlspace
2,046.0
0.0280
40
2,292
R-13 Wall
990.0
0.1020
40
4,039
Milgard Classic Low-E Vinyl
368.0
0.3900
40
5,741
Wood Door
70.0
0.5000
40
1,400
R-38 Roof Attic
299.0
0.0250
40
299
Velux Comfort (75) Lowe2/Arg
9.0
0.3700
40
133
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (`) denote conduction
Infiltration:[ 1.00 X 1.077
Schedule Air Sensible
Fraction
through an interior surface
X 2,046 X
Area
another room
10.70 X 0.431
Height ACH
Page Total
/60] X
AT
13,904
TOTAL HOURLY HEAT LOSS FOR ROOM 20,676
EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 2014-05-23702:32:27 ID: 1338 Page 18 of 23
ROOM HEATING PEAK LOADS
Project Name
STELLING RESIDENCE
Date
5/23/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name SECOND FLOOR LIVING
Floor Area 1,213.0ft'
Indoor Dry Bulb Temperature 68 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 28 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
40
Btu/hr
R-30 Floor Crawlspace
1,213.0
0.0280
40
1,359
R-13 Wall
1,240.0
0.1020
40
5,059
Milgard Classic Low -E Vinyl
226.0
0.3900
40
3,526
R-38 Roof Attic
1,213.0
0.0250
40
1,213
Items shown with an asterisk (`) denote conduction
Infiltration:[ 1.00 X 1.077
Schedule Air Sensible
Fraction
through an interior surface
X 1,213 X
Area
another room
9.20 X 0.501
Height ACH
Page Total
/60] X
AT
11,156
= 4,015
TOTAL HOURLY HEAT LOSS FOR ROOM 15,171
EnergyPro 5.1 by EnergySoft User Number.• 5750 RunCode: 2014-05-23702:32:27 ID: 1338 Page 19 of 23
ROOM HEATING PEAK LOADS
Project Name
STELLING RESIDENCE
Date
512312014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name FIRST FLOOR LIVING
Floor Area 525.0 ftz
Indoor Dry Bulb Temperature 68 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 28 OF
Conduction
Area
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
Btu/hr
R-30 Floor Craw/space
525.0
X
0.0280
40
=
588
R-13 Wall
744.0
X
0.1020
40
=
3,036
Milgard Classic Low -E Vinyl
114.0
X
0.3900
40
=
1,778
Wood Door
24.0
X
0.5000
40
=
480
R-38 Roof Attic
243.0
X
0.0250
40
=
243
Velux Comfort (75) Lowe2/Arg
9.0
X
0.3700
40
=
133
X
_
X
_
X
=
X
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
40
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denole conduction
Infiltration:[ 1.00 x 1.077
Schedule Air Sensible
Fraction
through an interior surface to
X 525 X
Area Ceiling
another room
10.00 X 0.343
Height ACH
Page Total
/60] X
AT
6,258
_ 1,293
TOTAL HOURLY HEAT LOSS FOR ROOM 7,551
EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 2014-05-23T02:32:27 ID: 1338 Page 20 of 23
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
STELLING RESIDENCE
5/23/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name FIRST FLOOR LIVING
Outdoor Dry Bulb Temperature
88 OF
Floor Area 2,046.0 ft2
Outdoor Wet Bulb Temperature
68 °F
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
30 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-30 Floor Craw/space 2,046.0 X 0.0280 X
4.0 =
229
R-13 Wall (W) 230.0 X 0.1020 X
13.0 =
305
Wood Door (W) 70.0 X 0.5000 X
13.0 =
455
R-13 Wall (N) 377.0 X 0.1020 X
3.0 =
115
R-13 Wall (E) 88.0 X 0.1020 X
13.0 =
117
R-13 Wall (S) 295.0 X 0.1020 X
6.0 =
181
R-38 Roof Attic (E) 299.0 X 0.0250 X
37.0 =
277
X X
=
X X
=
Page Total
1,678
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
Window (W) 0.0 X 14.9 + 115.0
X 37.4
= 4,300
Window (N) 0.0 X 14.9 + 42.0
X 14.9
= 625
Window (E) 0.0 X 14.9 + 126.0
X 37.4
= 4,711
Window (S) 0.0 X 14.9 + 85.0
X 20.5
= 1,739
Skylight (E) 0.0 X 11.9 + 9.0
X 52.7
= 474
X +
X
=
X +
X
=
X +
X
-
X +
X
-
Page Total
11,849
Internal Gain
Btu/hr
Occupants 3.0 Occupants X 230 Btuh/occ.
=
690
Equipment 1.0 Dwelling Unit X 1,600 Btu
=
1,600
Infiltration: 1.077 X 0.83 X 126.69 X 13 =
1,478
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
17,295
Latent Gain
Btu/hr
Occupants 3.0 Occupants X 200 Btuh/occ.
=
600
Infiltration: 4,830 X 0.83 X 126.69 X 0.00084 =
428
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,028
EnerqvPro 5.1 by EnerqySoft User Number: 5750 Run Code: 201405-23702:32:27 0. 1338
Page 21 of 23
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
STELL/NG RESIDENCE
5/23/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
SECOND FLOOR LIVING
Outdoor Dry Bulb Temperature
88 OF
Floor Area
1,213.0 ft'
Outdoor Wet Bulb Temperature
68 OF
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
30 OF
Opaque Surfaces
Orientation Area ll -Factor
CLTD'
Btu/hr
R-30 Floor Crawlspace
1,213.0 X 0.0280 X
4.0 =
136
R-13 Wall
281.0 X 0.1020 X
13.0 =
373
R-13 Wall
(N) 317.0 X 0.1020 X
3.0 =
97
R-13 Wall
(E) 317.0 X 0.1020 X
13.0 =
420
R-13 Wall
(S) 325.0 X 0.1020 X
6.0 =
199
R-38 Roof Attic
(E) 1,213.0 X 0.0250 X
37.0 =
1,122
X X
=
X X
=
X X
=
Page Total
2,347
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
Window
(W) 0.0 X 14.9 + 62.0
X 37.4
= 2,318
Window
(N) 0.0 X 14.9 + 62.0
X 14.9
= 922
Window
(E) 0.0 X 14.9 + 44.0
X 37.4
= 1,645
Window
(S) 0.0 X 14.9 + 58.0
X 20.5
= 1,187
X +
X
-
X +
X
=
X +
X
=
X +
X
=
X +
X
-
Page Total
6,072
Internal Gain
Btu/hr
Occupants
3.0 Occupants X 230 Btuh/occ.
=
690
Equipment
0.0 Dwelling Unit X 1,600 Btu
=
0
Infiltration: 1.077
X 0.83 X 75.11 X 13 =
876
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
9,985
Latent Gain
Btu/hr
Occupants
3.0 Occupants X 200 Btuh/occ.
=
600
Infiltration: 4,830
X 0.83 X 75.11 X 0.00084 =
254
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
854
Ener Pro 5.1 by EnerqySoft
User Number: 5750 Run Code: 2014-05-23T02:32:27 1D: 1338
Page 22 of;
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
STELL/NG RESIDENCE
5/23/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name FIRST FLOOR LIVING
Outdoor Dry Bulb Temperature
88 OF
Floor Area 525.0 ft'
Outdoor Wet Bulb Temperature
68 OF
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
30 OF
Opaque Surfaces Orientation Area LI -Factor
CLTD'
Btu/hr
R-30 Floor Crawlspace 525.0 X 0.0280
X
4.0 =
59
R-13 Wall (W) 260.0 X 0.1020
X
13.0 =
345
R-13 Wall (N) 58.0 X 0.1020
X
3.0 =
18
Wood Door (N) 24,0 X 0.5000
X
3.0 =
36
R-13 Wall (E) 200.0 X 0.1020
X
13.0 =
265
R-13 Wall (S) 226.0 X 0.1020
X
6.0 =
138
R-38 Roof Attic (E) 243.0 X 0.0250
X
37.0 =
225
X
X
=
X
X
=
Page Total
1,086
Items shown with an asterisk (') denote conduction through an interior surface to another room.
t. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
Window (N) 0.0 X 14.9 +
72.0
X 14.9
= 1,071
Window (E) 0.0 X 14.9 +
30.0
X 37.4
= 1,122
Window (S) 0.0 X 14.9 +
12.0
X 20.5
= 246
Skylight (E) 0.0 X 11.9 +
9.0
X 52.7
= 474
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
Page Total
2,912
Internal Gain
Btu/hr
Occupants 3.0 Occupants X 230
Btuh/occ.
=
690
Equipment 1.0-d Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.077 X 0.83 X 24.19 X 13 =
282
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
6,570
Latent Gain
Btu/hr
Occupants 3.0 Occupants X 200
Btuh/occ.
=
600
Infiltration: 4,830 X 0.83 X 24.19 X 0.00084 =
82
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
682
Ener Pro 5.1 by Ener Soft User Number: 5750 RunCode: 2014 05-23 702:32:27 ID: 1338
Pae 23 of 23