Loading...
14040087CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10438 N STELLING RD CONTRACTOR: JOSHUA PERMIT NO: 14040087 CONSTRUCTION & REMODELING OWNER'S NAME: HONGQI HU 10613 GASCOIGNE DR DATE ISSUED: 06/30/2014 OWNER'S PHONE: 4087253692 CUPERTINO, CA 95014 PHONE NO: (408) 725-3692 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ CONSTRUCT (N) 2 STORY SFD (3,259 S.F.) WITH License Class_ Lic. 0-21 ATTACHED 2 CAR GARAGE (431 S.F.) (ATTACHED a �� GRANNY Contractor ate wl UNIT BP# 14040088)(DEMO PERMIT # 14060104) 1 hereby affirm that am licensed;QWSi ori [Chapter 9 (commencing with Section 7000) of Division 3 of the Business & ProfessionsreV° on #I ise layout of interior wall, add (2) skylights- issd Code and that my license is in full force and effect. cl/ 014 1 hereby affirm under penalty of perjury one of the following two decl I have and will maintain a certificate of consent to self -insure for W Compensation, as provided for by Section 3700 of the Labor Code, Sq. Ft Floor Area: Valuation: $400000 performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 32630096.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FR ST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I p granting of this permit. Additionally, the applicant understands and will comply Issued by: Date: with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. ^� Signature to �r �� RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is 61 installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: 1 hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should 1 store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District 1 performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this/ Owner or authorized agent: Date: / permit is issued. - I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, atter making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18, Signature Date CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building cDcupertino.org ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI [Z REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS A / , I APN k OWNER NAME PHONE � _ /. _ EMAIL STREET ADDRESS CITY, STATE, ZIP CONTACT NAME PHONE E-MAIL STREET ADDRESS CITY, STATE, ZIP FAX ❑ OWNER ❑ O,kT'ER-BUILDErR ❑ OWT'ER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME D /� ( L j / i 'Y ] LICENSE NUMBER I (� ,yENGINEER LICENSE TYPE K ✓ BUS. LIC k COMPANYNAME f E-MAIL FAX STREETADDRESS /��� % 1� CITY,fTATE,ZIP /9 ` _ /�,p bl�/ /i (.may l lL PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC k COMPANYNAMEZ;' _olio CP J 1. (l (( C E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK 1 �` /d^ Kd L 1A Lt �. ei �I' pi ram' oar Ov'a'ie� aA � r o dtnc�i r h,l.1v�• r I f of r'�G Thr. EXISTING USE PROPOSED USE CONSTR TYPE k STORIES USE TYPE OCC. SQ.FT. VALUATION (S) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NEI- AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH k DWELLING UMTS: IS A SECOND UNrr ❑ YES SECOND STORY ❑ YES ....— BEING ADDED? I] NO ADDITION? []NO PRE -APPLICATION [:)YES IF YES, PROVIDE COPY OF PLANNING APPL k NO PLANNING APPROVAL LETTER IS THE BLDG AN I] YESRECEIVED EICHLER HOME? NO TiY, r ' TOTAL V.AQ_ TION: ❑ ❑ i By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. ` Date: % Signature of ApplicanUAgent: ! SUPPLEMENTAL INF 4ATION REQUIRED PLO cliczxPE, ROUTING SLIP' ouER ��>+-coaNTER uYi✓DINc rtaN xt.��w New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit Is required prior to Issuance of buildi t ,. permit for new building. p g• ❑� � EXPRESS�f r � L1 PLANNING P&AN REVIEW t _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure CI''sTArpAiiD ❑ rvBLlc`woRxs ' form if any Hazardous Materials are being used as part ofthis project.-~ ❑, Copy of Planning Approval Letter or Meeting with Planning prior to LARGE r� PIR$ DEPS' SAAITARY submittal of Building Permit application. MAJOR SEWER DISTRICT , = y� ❑ ENVIRONkENTALIiEALTAr, BldgApp 2011.doc revised 06/21/11 CITY OF CUPERTINOFM_7 FEE ESTIMATOR BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School Diclrirt etc )- These fees are hated on flip. nreliminary informntion availahle and are only an estimate_ Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 711//3) ADDRESS: 10438 n stelling rd DATE: 12/17/2014 REVIEWED BY: Mendez APN: BP#: "VALUATION: j$1,000 "PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: PENTAMATION PERMIT TYPE: WORK revision #1- revise layout of interior wall add 2 skylights- issd otc 12/18/2014 SCOPE PME Plan Check: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School Diclrirt etc )- These fees are hated on flip. nreliminary informntion availahle and are only an estimate_ Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 711//3) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 Select a Misc Bldg/Structure or Element of a Building Suppl. PC Fee: E) Reg. ® OT 0.0 1 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 SuppL Insp. Fee -.0 Reg. Q OT 1 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? 0 Yes (j) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure E) Strom Motion Fee. iBSEISMICR $0.50 F-1-1 # $859.00 Revisions IREVSFDW1 SFDWL Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $1.50 $859.00 TOTAL FEE: F $860.50 Revised: 10/01/2014 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10438 N STELLING RD CONTRACTOR: JOSHUA PERMIT NO: 14040087 CONSTRUCTION & REMODELING OWNER'S NAME: HONGQI HU 10613 GASCOIGNE DR DATE ISSUED: 06/30/2014 OWNER'S PHONE: 4087253692 CUPERTINO, CA 95014 PHONE NO: (408) 725-3692 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ V26.r CONSTRUCT (N) 2 STORY SFD (3,259 S.F.) WITH License Class__,_.__ Lic. N �9 ATTACHED 2 CAR GARAGE (431 S.F.) (ATTACHED 6/ NY Contractor i !t , Date O UNIT BP# 14040088)(DEMO PERMIT # 14060104) I hereby affirm that I am licen under the pr visions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: 1 have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $400000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 32630096.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that l have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 D IT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 � A7LLED INSPECTION. indemnifyand keepharmless the Cit of Cupertino against liabilities, Y p e judgments, costs, and expenses which may accrue against said Cit in consequence of the n p Y g Y q Date: granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, 1 agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" 012 BETTER I, as owner of the property; or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS NIATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(x) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should 1 use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District 1 performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this is issued. Owner or authorized agent: Date: Q permit I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must l hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTI FICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CVPER-FINN CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 \k� (408) 777-3228 • FAX (408) 777-3333 • buildinp(aa)cupertino.org, ® NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/T1 ❑ REVISION /DEFERRED ORIGINAL PERMT II PROJECT ADDRESS -7 10438 STELLING ROAD APNa 326-30-096 OWNERNAME HONGQI HU PHONE 408.725.3692 E-MAIL `T�r///I j04 ((([ vI C STREET ADDRESS 10613 GASCOIGNE DR CITY. STATE, ZIP CUPERTINO CA 95014 FAX CONTACT NAME FRANK L. HO PHONE 408.892.5020 7 E-MAIL FRANKLHO@yahoo.com STREET ADDRESS 12480 Saratoga Avenue CITY, STATE, ZIP Saratoga, CA 95070 FAX ❑ OWNER ❑ OW'N'ER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT 12 ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME TBD LICENSE NUMBER LICENSE TYPE BUS. LIC d COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME FRANK HO LICENSE NUMBER 029889 BUS. LIC d COMPANY NAME E-MAIL FAX STREET ADDRESS 12480 SARATOGA AVE CITY, STATE, ZIP Saratoga CA 95070 PHONE 408.892.5020 DESCRIPTION OFwoRK New 2 stories house with 4 bedrooms, 4.5 bathrooms, AAAttJ �'sJEti l�. Also include 2 cars garage. Total living area is 3259- Total garage is 431sf EXISTING USE PROPOSED USE CONSTR. TYPE a STORIES SFR SFR VB 2 USE TYPE OCC. SQ.FT. VALUATION (S) EXISTAREAL 1 ,246 NEW FAREA LOOR AREADEM 1,246 NETAAREA V I j PL �j2 GC1 Y00� 000 BATHROOM REMODEL AREA KITCHEN REMODEL AREA OTHER REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA LJ DETACH 3b`j Za 411 431 ®ATTACH N DWELLING UNITS. IS A SECOND UNIT ® YES SECOND STORY ® YES 2 BEING ADDED? ❑NO ADDITION? NO PR&APPLICATION NI YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YESEl VED BY: TOTAL VALUATION: PLANNG APPL N ❑ NO PLANNING APPROVAL LETTER BJ EICHLER HOME? ® NO r //YL//'.f���p' (�,v (& By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorise r presentatives of Cupertino to enter the above -identified property for inspection purposes. Signature of ApplicantlAgent: Da SUPPLEMENTAL INFORMA N REQUIRED PLAN CHECK TYPE ROUTING SLIP ❑ OVER-'I'9E-COUNTER ❑ BUILDING PLAN REVIEW _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to El El SANITARY SEWER DISTRICTsubmittal of Building Permit application. MAJOR ❑ ENVIRONMENTAL HEALTH BldgApp 2011.doc revised 06/21/11 oo v) CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION OCCUPANCY TYPE: 10438 N STELLING RD DATE: 04/15/2014 REVIEWED BY: MELISSA imADDRESS: APN: 326 30 096 BP#: ��� VALUATION: $400,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: New Construction PRIMARY USE: SFD or Duplex 2nd Unit? Yes No TiPENTAMATION PERMIT TYPE: 1 R3SFD WORK CONSTRUCT N 2 STORY SFD (3,259 S.F. WITH ATTACHED 2 CAR GARAGE 431 S.F. SCOPE II-B,III-B,IV,V-B OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,III-B,IV,V-B 3,259 $3,037.08 IR3PLNCK $3,062.92 IR3INSP U (Private Gar/Ag Bldg) II-B,III-B,IV,V-B 431 $0.00 IUIPLNCK $1,252.00 IUIINSP Permit Fee: $4,314.92 Suppl. Insp. Fee:Q Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: TOTALS: 3,690 $3,037.08 $4,314.92 Construction Tax: IBCONST4XR NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School ni.ctrict_ ote 1_ Those fee_c are ha.sed an the nreliminary information availahle and are oniv an estimate Contact the Dent for addn'I info. FEE ITEMS (Fee Resolution 11-053 Ef 7/1/131 FEE QTY/FEE MISC ITEMS Plan Check Fee: $3,037.08 Select a Misc Bldg/Structure or Element of a Building Suppl. PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $4,314.92 Suppl. Insp. Fee:Q Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: IBCONST4XR 1 # new units $659.99 G Work Without Permit? Yes (2) No $0.00 Advanced Planning Fee: IPLLONGR $516.60 Select a Non -Residential Building or Structure d i Strong Motion Fee: IBSEISMICR $40.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $16.00 SUBTOTALS: $8,584.59 $0.00, TOTAL FEE: $8,584.59 Revised: 04/01/2014 4 BUILDING ENERGY ANALYSIS REPORT PROJECT: STELLING RESIDENCE 10438 N. STELLING ROAD CUPERTINO, CA 95014 Project Designer: STUDIO 61 ARCHITECTS INC 12480 SARATOGA AU SARATOGA, CA 95 V " ,, 408.892.5020 RECEIVED Wn Report Prepared by: MAY 2 7 2014 STUDIO 61 ARCHITECTS INC Job Number: 1338 Date: 5/23/2014 mM yyyy ���wU jj�� wrvm w% fI, p'm arX ^{� e mrci. IJ�ti 4 X�rm;;h� rnx tlG Nwwm�°�'"0rw'�fi ygm✓mni�;mrmn'+�� The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 5750 Run Code: 2 0 1 4-05-23 70 2:32:27 ID: 1338 1 TABLE OF CONTENTS I Cover Page Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 15 Room Heating Peak Loads 18 Room Cooling Peak Loads 21 5.1 by EnergySoft ID: 1338 User Number: 5750 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name STELLING RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/23/2014 Project Address 10438 N. STELLING ROAD CUPERTIN California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 3,784 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Floor Wood Framed w/Crawl Space R-30 3,784 New Wall Wood Framed R-13 2,974 New Door Opaque Door None 94 New Roof Wood Framed Attic R-38 1,755 Radiant Barrier Venting New FENESTRATION U- Exterior Orientation Area(e) Factor SHGC Overhang Sidefins Shades Status Front (lAq 177.0 0.390 0.37 none none Bug Screen New Left (N) 176.0 0.390 0.37 none none Bug Screen New Rear (E) 200.0 0.390 0.37 none none Bug Screen New Right (S) 155.0 0.390 0.37 none none Bug Screen New Skylight 9.0 0.370 0.29 none none None New Skylight 9.0 0.370 0.29 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Gravity Wall Furnace 67% AFUE No Cooling 13.0 SEER Setback New 1 Gravity Wall Furnace 67% AFUE No Cooling 13.0 SEER Setback New 1 Gravity Wall Furnace 67% AFUE No Cooling 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC FOR FIRST FLOOR Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC FOR SECOND FLO Ducted Ducted Attic, Ceiling Ins, vented 8.0 New FURNACE FOR SECONDr Ductless / No Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New 1 Instant Gas 0 0.84 Kitchen Pipe Ins New EnergyPro 5.1 by EnergySoft User Number.- 5750 RunCode: 201405-23T02:32:27 ID: 1338 Page 3 of 23 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name STELLING RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/23/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System Williams 2519622 does not include a cooling system, field verification is not necessary. The HVAC System Williams 2519622 does not include a cooling system, field verification is not necessary. The HVAC System Milliams 2519622 does not include a cooling system, field verification is not necessary. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. The Roof R-38 Roof Attic includes an Airgap below Roofing 1/150 Vent Area 50% of Vents Located High requires verification. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ene Soft User Number: 5750 Run Code: 20 1 4-0 5-23 70 2:32:27 ID: 1338 Page 4 of 23 PERFORMANCE CERI'IFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date STELLING RESIDENCE D Multi Family ❑ Existing+ Addition/Alteration 1512312014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftp- r Space Heating 25.15 24.84 0.31 Space Cooling 6.78 6.48 0.30 Fans 4.69 4.36 0.33 Domestic Hot Water 18.34 12.72 5.62 Pumps 0.00 0.00 0.00 Totals 54.96 48.41 6.56 Percent Better Than Standard: 11.9 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (w) 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 2.00 (vu 1,018 177 Fuel Available at Site: Natural Gas (N) 952 176 Raised Floor Area: 3,784 (E) 805 200 Slab on Grade Area: 0 (S) 1,001 155 Average Ceiling Height: 10.1 Roof 1,773 18 Fenestration Average U -Factor: 0.39 TOTAL: 726 Average SHGC: 0.37 Fenestration/CFA Ratio: 19.2 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company STUDIO 61 ARCHITECTS INC 5/23/2014 Address Name City/State/ZipCity/State/Zip Phone Si ed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Despigner or Owner& Professions Code) liner per gs iiness Comany Address 12480 SARA TOGA AVE Name FRANK LINH HO City/State/Zip SARATOGA, CA 95070 Phone 408.892.5020 Signed License # Date Ener Pro 5.1 by EnerqySoft User Number.' 5750 RunCode: 2014-05-23T02:32:27 ID: 1338 Page 5 of 23 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name STELLING RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family CI Existing+ Addition/Alteration Date 1512312014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Floor 2,046 0.028 R-30 0 180 New 4.4.1-A7 FIRST FLOOR LIVING Wall 230 0.102 R-13 270 90 New 4.3.1-A3 FIRST FLOOR LIVING Door 70 0.500 None 270 90 New 4.5.1-A4 FIRST FLOOR LIVING Wall 377 0.102 R-13 0 90 New 4.3.1-A3 FIRST FLOOR LIVING Wall 88 0.102 R-13 90 90 New 4.3.1-A3 FIRST FLOOR LIVING Wall 295 0.102 R-13 180 90 New 14.3.1-A3 FIRST FLOOR LIVING Roof 299 0.025 R-38 90 18 New 4.2.1-A21 FIRST FLOOR LIVING Floor 1,213 0.028 R-30 0 180 New 4.4.1-A7 SECOND FLOOR LIVING Wall 281 0.102 R-13 270 90 New 4.3.1-A3 SECOND FLOOR LIVING Wall 317 0.102 R-13 0 90 New 4.3.1-A3 SECOND FLOOR LIVING Wall 317 0.102 R-13 90 90 New 4.3.1-A3 SECOND FLOOR LIVING Wall 325 0.102 R-13 180 90 New 4.3.1-A3 SECOND FLOOR LIVING Roof 1,213 0.025 R-38 90 18 New 4.2.1-A21 SECOND FLOOR LIVING Floor 525 0.028 R-30 0 180 New 4.4.1-A7 SECONDARY UNIT Wall 260 0.102 R-13 270 90 New 4.3.1-A3 SECONDARY UNIT Wall 58 0.102 R-13 0 90 New 4.3.1-A3 SECONDARY UNIT FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Mindow 115.0 0.390 NFRC 0.37 NFRC 270 New Milgard Classic Low -E Vinyl FIRST FLOOR LIVING 2 WIndow 42.0 0.390 NFRC 0.37 NFRC 0 New Milgard Classic Low -E Vinyl FIRST FLOOR LIVING 3 Window 126.0 0.390 NFRC 0.37 NFRC 90 New Milgard Classic Low -E Vinyl FIRST FLOOR LIVING 4 Mindow 85.0 0.390 NFRC 0.37 NFRC 180 New Milgard Classic Low -E Vinyl FIRST FLOOR LIVING 5 Skylight 9.0 0.370 NFRC 0.29 NFRC 90 New Velux Comfort (75) Lowe2/Arg FIRST FLOOR LIVING 6 IMndow 62.0 0.390 NFRC 0.37 NFRC 270 New Milgard Classic Low -E Vinyl SECOND FLOOR LIVING 7 Mindow 62.0 0.390 NFRC 0.37 NFRC 0 New Milgard Classic Low -E Vinyl SECOND FLOOR LIVING 8 Window 44.0 0.390 NFRC 0.37 NFRC 90 New Milgard Classic Low -E Vinyl SECOND FLOOR LIVING 9 Window 58.0 0.390 NFRC 0.37 NFRC 180 New Milgard Classic Low -E Vinyl SECOND FLOOR LIVING 10 Mindow 72.0 0.390 NFRC 0.37 NFRC 0 New Milgard Classic Low -E Vinyl SECONDARY UNIT 11 Mindow 30.0 0.390 NFRC 0.37 NFRC 90 New Milgard Classic Low -E Vinyl SECONDARY UNIT 12 Mindow 12.0 0.390 NFRC 0.37 NFRC 180 New Milgard Classic Low -E Vinyl SECONDARY UNIT 13 Skylight 9.0 0.370 NFRC 0.29 NFRC 90 New Velux Comfort (75) Lowe2/Arg SECONDARY UNIT (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 None 1.00 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 None 1.00 EnergyPro 5.1 by Ener Soft User Number: 5750 Run Code: 201405-23T02:32:27 ID: 1338 Page 6 of 23 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project NameBuilding STELLING RESIDENCE Type m Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 5/23/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Door 24 0.500 None 0 90 New 4.5.1-A4 SECONDARY UNIT wall 200 0.102 R-13 90 90 New 4.3.1-A3 SECONDARY UNIT wall 226 0.102 R-13 180 90 New 4.3.1-A3 SECONDARY UNIT Roo! 243 0.025 R-38 90 18 New 4.2.1-A21 SECONDARY UNIT FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Len H t LExt REA Left Fin Dist Len H t Right Fin Dist Len H t EnergyPro 5.1 by EnergySoft User Number. 5750 Run Code: 2014-05-23T02:32:27 ID. 1338 Pae 7 of 23 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name STELLING RESIDENCE Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/23/2014 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New Existing Altered Removed Volume Year Built HVAC FOR FIRST FLOOR FIRST FLOOR LIVING 2,046 21,892 HVAC FOR SECOND FLOOR SECOND FLOOR LIVING 1,213 11,160 FURNACE FOR SECONDARY FIRST FLOOR LIVING 525 5,250 Totals 3,784 0 0 0 HVAC SYSTEMS System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC FOR FIRST FLOOR 1 Gravity Wall Fumac 67% AFUE No Cooling 13.0 SEER Setback New HVAC FOR SECOND FLOOR 1 Gravity Wall Furnace 67% AFUE No Cooling 13.0 SEER Setback New FURNACE FOR SECONDARY 1 Gravity Wall Furnace 67% AFUE No Cooling 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Cooling Duct Location Duct R-Value Ducts Tested? Status HVAC FOR FIRST FLOOR Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New HVAC FOR SECOND FLOOR Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New FURNACE FOR SECONDARY Ductless/ No Fan Ductless n/a n/a ❑ New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Takagi T-K2 1 Instant Gas Kitchen Pipe Ins 185,000 0 0.84 n/a n/a New Takagi T-K2 1 Instant Gas Kitchen Pipe Ins 185,000 0 0.84 n/a n/a New MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 Q System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by Ener Soft User Number: 5750 Run Code: 201405-23702:32:27 ID: 1338 Page 8 of 23 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name STELLING RESIDENCE Date 5/23/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(')3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(1)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Page 9 of 23 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date STELLING RESIDENCE 5/23/2014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of ILL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 f12 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 5750 Run Code: 201405-23702:32:27 ID: 1338 Page 10 of 23 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date STELLING RESIDENCE 5/23/2014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11 : Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoR User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Page 11 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name STELLING RESIDENCE Date 5/23/2014 System Name HVAC FOR FIRST FLOOR Floor Area 2,046 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 822 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 25,000 17,295 1,028 414 20,676 Total Output Btuh 25,000 0 758 0 Output Btuh/s ft 12.2 509 Cooling System 0 Output per System 0 0 0 0 0 Total Output (Btuh) 0 3,070 -3,070 758 1,028 19,121 Total Output Tons 0.0 509 Total Output (Btuh/s ft) 0.0 Total Output s f /Ton 00 21,382 Air System CFM perSystem 655 HVAC EQUIPMENT SELECTION Airflow cfm 655 Williams 2519622 0 0 25,000 Airflow (cfm/s ft) 0.32 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0% Total Adjusted System Output 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Aug 3 PM 25,000 Jan 1 AM Outside Air (cfm/s ft 0.00 Note: values above given at ARI conditions 1 HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 28 IF 67 IF Outside Air Ar- 0 cfm Supply Fan 655 cfm 67 OF 70 IF 115 IF 0. M Heating Coil G 114 IF — DOOM 68 IF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 88 / 68 IF 75 / 62 IF 78 / 62 IF 55 / 54 OF Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF 655 cfm 46.0% ROOM Ifl' 75/62°F 75/61 OF EnergyPro 5.1 by EnergySoff User Number., 5750 Run Code: 201405-23T02:32:27 /D: 1338 Page 12 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name STELLING RESIDENCE Date 5/23/2014 System Name HVAC FOR SECOND FLOOR Floor Area 1,213 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 473 9,985 Return Vented Lighting 0 Return Air Ducts 294 Return Fan 0 Ventilation 0 0 Supply Fan 3,070 Supply Air Ducts 294 TOTAL SYSTEM LOAD 13,642 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 25,000 854 305 15,171 Total Output (Btuh) 25,000 Output Btuh/s ft 20.6 556 Cooling System 0 Output per System 0 0 0 0 Total Output (Btuh) 0 854 -3,070 Total Output (Tons) 0.0 556 Total Output (Btuh/s ft) 0.0 Total Output (s ft/Ton) 0.0 13,213 Air System CFM per System 655 HVAC EQUIPMENT SELECTION Airflow cfm 655 Williams 2519622 0 0 25,000 Airflow cfm/s ft) 0.54 Airflow cfm/Ton) 0.0 Outside Air % 00% Total Adjusted System Output 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Aug 3 PM 25,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 28 IF 67 OF Outside Air AV - 0 cfm Supply Fan 655 cfm 67°F 72 OF 115 IF Heating Coil 4 ETF] F --- 1.4 114 OF -------------M 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 88 / 68 OF 75162 OF 80 / 63 OF 55 / 53 IF Outside Air 0 cfm Supply I Fan Cooling Coil 551 54 OF 655 cfm 46.1 % ROOM inl, 75/62°F 75/61 IF EnergyPro 5.1 by EnergySoff User Number.' 5750 Run Code: 201405-23T02:32:27 ID: 1338 Page 13 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name STELLING RESIDENCE Date 5/23/2014 System Name FURNACE FOR SECONDARY UNIT Floor Area 525 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 305 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 25,000 6,570 682 149 7,551 Total Output Btuh 25,000 0 Output (Btuh/s ft) 47.6 0 0 Cooling System 0 0 Output per System 0 0 0 0 0 Total Output Btuh) 0 3,070 682 -3,070 Total Output (Tons) 0.0 0 0 Total Output (Btuh/s ft) 0.0 Total Output s ft/Ton 0.0 9,640 4,481 Air System CFM per System 655 HVAC EQUIPMENT SELECTION Airflow cfm 655 Williams 2519622 0 0 25,000 Airflow (cfm/s ft) 1.25 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0% Total Adjusted System Output 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Aug 3 PM 25,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 28 OF 68 OF Outside Air 0 cfm Supply Fan AL 655 cfm 68 OF 72 OF 115 OF a Heating Coil 115 IF ---- �ROOMh 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 88/68°F 75/61 IF 79/63°F 55/53°F Outside Air Ar 0 cfm Supply Fan Cooling Coil 55 / 53 OF 655 cfm /��y�y� M 45.8 % ROOM 75 / 61 OF 75 / 61 IF EnergyPro 5.1 by EnergySoff User Number: 5750 Run Code: 2014-05-23T02:32:27 ID: 1338 Page 14 of 23 ROOM LOAD SUMMARY Project Name Date STELLING RESIDENCE 5/23/2014 System Name Floor Area HVAC FOR FIRST FLOOR 2,046 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM Sensible Latent CFM I Sensible FIRST FLOOR LIVING FIRST FLOOR LIVING 1 1 8221 17,2951 1,028 822 17,2951 1,028 4141 20,676 PAGE TOTAL TOTAL 822 17,295 1,028 414 20,676 822 17,295 1,028 414 20,676 " Total includes ventilation load for zonal systems. Ener Pro 5.1 by EnerqySoft User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Pae 15 of 23 ROOM LOAD SUMMARY Project Name Date STELLING RESIDENCE 5/23/2014 System Name Floor Area HVAC FOR SECOND FLOOR 1,213 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible Latent CFM Sensible Latent CFM Sensible SECOND FLOOR LIVING SECOND FLOOR LIVIN 1 1 473 9,985 854 473 9,985 854 305 15,171 PAGE TOTAL TOTAL Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 2014-05-2 3 70 2:32:27 473 9,985 854 305 15,171 473 9,985 854 305 15,171 ID: 1338 [ROOM LOAD SUMMARY STELLING RESIDENCE 5/23/2014 System Name Floor Area FURNACE FOR SECONDARY UNIT 525 ROOM LOAD SLIMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent I CFM Sensible SECONDARY UNIT FIRST FLOOR LIVING 1 305 6,570 682 305 6,570 682 149 7,551 PAGE TOTAL TOTAL' Total includes ventilation load for zonal 305 6,570 682 149 7,551 305 6,570 682 149 7,551 EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 201405-23T02:32:27 ID: 1338 Page 17 of 23 ROOM HEATING PEAK LOADS Project Name STELLING RESIDENCE Date 5/23/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name FIRST FLOOR LIVING Floor Area 2,046.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X AT 'F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1 Btu/hr R-30 Floor Crawlspace 2,046.0 0.0280 40 2,292 R-13 Wall 990.0 0.1020 40 4,039 Milgard Classic Low-E Vinyl 368.0 0.3900 40 5,741 Wood Door 70.0 0.5000 40 1,400 R-38 Roof Attic 299.0 0.0250 40 299 Velux Comfort (75) Lowe2/Arg 9.0 0.3700 40 133 X X X X X X X X X X X X X X Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 2,046 X Area another room 10.70 X 0.431 Height ACH Page Total /60] X AT 13,904 TOTAL HOURLY HEAT LOSS FOR ROOM 20,676 EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 2014-05-23702:32:27 ID: 1338 Page 18 of 23 ROOM HEATING PEAK LOADS Project Name STELLING RESIDENCE Date 5/23/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name SECOND FLOOR LIVING Floor Area 1,213.0ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 40 Btu/hr R-30 Floor Crawlspace 1,213.0 0.0280 40 1,359 R-13 Wall 1,240.0 0.1020 40 5,059 Milgard Classic Low -E Vinyl 226.0 0.3900 40 3,526 R-38 Roof Attic 1,213.0 0.0250 40 1,213 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 1,213 X Area another room 9.20 X 0.501 Height ACH Page Total /60] X AT 11,156 = 4,015 TOTAL HOURLY HEAT LOSS FOR ROOM 15,171 EnergyPro 5.1 by EnergySoft User Number.• 5750 RunCode: 2014-05-23702:32:27 ID: 1338 Page 19 of 23 ROOM HEATING PEAK LOADS Project Name STELLING RESIDENCE Date 512312014 ROOM INFORMATION DESIGN CONDITIONS Room Name FIRST FLOOR LIVING Floor Area 525.0 ftz Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr R-30 Floor Craw/space 525.0 X 0.0280 40 = 588 R-13 Wall 744.0 X 0.1020 40 = 3,036 Milgard Classic Low -E Vinyl 114.0 X 0.3900 40 = 1,778 Wood Door 24.0 X 0.5000 40 = 480 R-38 Roof Attic 243.0 X 0.0250 40 = 243 Velux Comfort (75) Lowe2/Arg 9.0 X 0.3700 40 = 133 X _ X _ X = X = _ = = = = = = = = = = = = = = = = 40 X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denole conduction Infiltration:[ 1.00 x 1.077 Schedule Air Sensible Fraction through an interior surface to X 525 X Area Ceiling another room 10.00 X 0.343 Height ACH Page Total /60] X AT 6,258 _ 1,293 TOTAL HOURLY HEAT LOSS FOR ROOM 7,551 EnergyPro 5.1 by EnergySoft User Number: 5750 RunCode: 2014-05-23T02:32:27 ID: 1338 Page 20 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date STELLING RESIDENCE 5/23/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name FIRST FLOOR LIVING Outdoor Dry Bulb Temperature 88 OF Floor Area 2,046.0 ft2 Outdoor Wet Bulb Temperature 68 °F Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-30 Floor Craw/space 2,046.0 X 0.0280 X 4.0 = 229 R-13 Wall (W) 230.0 X 0.1020 X 13.0 = 305 Wood Door (W) 70.0 X 0.5000 X 13.0 = 455 R-13 Wall (N) 377.0 X 0.1020 X 3.0 = 115 R-13 Wall (E) 88.0 X 0.1020 X 13.0 = 117 R-13 Wall (S) 295.0 X 0.1020 X 6.0 = 181 R-38 Roof Attic (E) 299.0 X 0.0250 X 37.0 = 277 X X = X X = Page Total 1,678 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (W) 0.0 X 14.9 + 115.0 X 37.4 = 4,300 Window (N) 0.0 X 14.9 + 42.0 X 14.9 = 625 Window (E) 0.0 X 14.9 + 126.0 X 37.4 = 4,711 Window (S) 0.0 X 14.9 + 85.0 X 20.5 = 1,739 Skylight (E) 0.0 X 11.9 + 9.0 X 52.7 = 474 X + X = X + X = X + X - X + X - Page Total 11,849 Internal Gain Btu/hr Occupants 3.0 Occupants X 230 Btuh/occ. = 690 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.077 X 0.83 X 126.69 X 13 = 1,478 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,295 Latent Gain Btu/hr Occupants 3.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,830 X 0.83 X 126.69 X 0.00084 = 428 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,028 EnerqvPro 5.1 by EnerqySoft User Number: 5750 Run Code: 201405-23702:32:27 0. 1338 Page 21 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date STELL/NG RESIDENCE 5/23/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name SECOND FLOOR LIVING Outdoor Dry Bulb Temperature 88 OF Floor Area 1,213.0 ft' Outdoor Wet Bulb Temperature 68 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area ll -Factor CLTD' Btu/hr R-30 Floor Crawlspace 1,213.0 X 0.0280 X 4.0 = 136 R-13 Wall 281.0 X 0.1020 X 13.0 = 373 R-13 Wall (N) 317.0 X 0.1020 X 3.0 = 97 R-13 Wall (E) 317.0 X 0.1020 X 13.0 = 420 R-13 Wall (S) 325.0 X 0.1020 X 6.0 = 199 R-38 Roof Attic (E) 1,213.0 X 0.0250 X 37.0 = 1,122 X X = X X = X X = Page Total 2,347 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (W) 0.0 X 14.9 + 62.0 X 37.4 = 2,318 Window (N) 0.0 X 14.9 + 62.0 X 14.9 = 922 Window (E) 0.0 X 14.9 + 44.0 X 37.4 = 1,645 Window (S) 0.0 X 14.9 + 58.0 X 20.5 = 1,187 X + X - X + X = X + X = X + X = X + X - Page Total 6,072 Internal Gain Btu/hr Occupants 3.0 Occupants X 230 Btuh/occ. = 690 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.077 X 0.83 X 75.11 X 13 = 876 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,985 Latent Gain Btu/hr Occupants 3.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,830 X 0.83 X 75.11 X 0.00084 = 254 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 854 Ener Pro 5.1 by EnerqySoft User Number: 5750 Run Code: 2014-05-23T02:32:27 1D: 1338 Page 22 of; RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date STELL/NG RESIDENCE 5/23/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name FIRST FLOOR LIVING Outdoor Dry Bulb Temperature 88 OF Floor Area 525.0 ft' Outdoor Wet Bulb Temperature 68 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area LI -Factor CLTD' Btu/hr R-30 Floor Crawlspace 525.0 X 0.0280 X 4.0 = 59 R-13 Wall (W) 260.0 X 0.1020 X 13.0 = 345 R-13 Wall (N) 58.0 X 0.1020 X 3.0 = 18 Wood Door (N) 24,0 X 0.5000 X 3.0 = 36 R-13 Wall (E) 200.0 X 0.1020 X 13.0 = 265 R-13 Wall (S) 226.0 X 0.1020 X 6.0 = 138 R-38 Roof Attic (E) 243.0 X 0.0250 X 37.0 = 225 X X = X X = Page Total 1,086 Items shown with an asterisk (') denote conduction through an interior surface to another room. t. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 14.9 + 72.0 X 14.9 = 1,071 Window (E) 0.0 X 14.9 + 30.0 X 37.4 = 1,122 Window (S) 0.0 X 14.9 + 12.0 X 20.5 = 246 Skylight (E) 0.0 X 11.9 + 9.0 X 52.7 = 474 X + X - X + X - X + X - X + X - X + X - Page Total 2,912 Internal Gain Btu/hr Occupants 3.0 Occupants X 230 Btuh/occ. = 690 Equipment 1.0-d Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.077 X 0.83 X 24.19 X 13 = 282 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,570 Latent Gain Btu/hr Occupants 3.0 Occupants X 200 Btuh/occ. = 600 Infiltration: 4,830 X 0.83 X 24.19 X 0.00084 = 82 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 682 Ener Pro 5.1 by Ener Soft User Number: 5750 RunCode: 2014 05-23 702:32:27 ID: 1338 Pae 23 of 23