B-2017-0508CITY OF CUPERTINO BUILDING PERMIT
isulldlINUALLHEJJ: _ CONTRACTOR: PERMIT NO: B-2017-0508
10618 MADRID RD WILLOW GLEN
ELECTRIC INC
SAN JOSE, CA 95155
OWNER'S NAME: Peter Chen
OWNER'S PHONE: 408-800-8925
LICENSED CONTRACTOR'S DECLARATION
License Class C10 Lic. #591918
Contractor WILLOW GLEN ELECTRIC INCDate 04/30/2018
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
1. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
0z I'bave and will maintain Worker's Compensation Insurance, as provided for by
�,/ Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
and state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
may accrue against said City in consequence of the granting of this permit.
Additionally, the applicant understands and will comply with all non -point
source regulatio s per the Cupertino Municipal Code, Section 9.18.
Signature,&,, Date 03/30/2017
DATE ISSUED: 03/30/2017
PHONE NO: (408) 289-9725
BUILDING PERMIT INFO:
X BLDG —ELECT _ PLUMB
_ MECH X RESIDENTIAL _ COMMERCIAL
JOB DESCRIPTION:
(N) EV CHARGING STATION (50 AMP) - GARAGE
Sq. Ft Floor Area: l Valuation: $1140.00
APN Number: Occupancy Type:
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS yANCE OR
180 DAYS F ON.
sued by: MELISSA
ate: 03/30/2017
I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS:
following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is
1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for
compensation, will do the work, and the structure is not intended or offered for inspection.
sale (Sec.7044, Business & Professions Code)
z. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant:
contractors to construct the project (Sec.7044, Business & Professions Code). Date: 03/30/2017
hereby affirm under penalty of perjury one of the following three declarations:
1. I have and will maintain a Certificate of Consent to self -insure for Worker's ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
z. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
3. I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the
Worker's Compensation laws of California. If, after making this certificate of
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
relating to building construction, and hereby authorize representatives of this city
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
Code, Section 9.18.
Signature Date
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
the Health & Safety Code, Sections 25505, 25533, and 25534.
Owner or authorized agent ---
Date: 03/30/2017 j '
CON TR
ON LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance
of work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
understand my plans shall be used as public records.
Licensed
Professional
ALTERNATIVE ENERGY PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95014-3265 A
(408) 7773228 - FAX (408) 7773333
--Z�a� � ass
PROJECT ADDRESS7,77
10618- -Madl,�,cj
, 0j_('
OWNER NAME
PHONT,�o 00 �?.� -T1,y.A1L,,/,,
A
STRECTADDRRSS 0
,, f �- 7ti oc"-�
(1-4 soJ- I
FAX
CONTACT NAME Mark Londre
P�'ONE (408)289-9725
HMAIL officegwillowglenelectric.com
STREET ADDRESS p. 0. Box 8430
CITY, STATE, ZIP San Jose, CA 95155 1
FAx (408)289-9725
11 OWNER 11 OWNER -BUILDER El OWNER AGENT VICONTRACTOR 1:1 CONTRACTOR AGENT 11 ARCHITECT 1:3 ENGINEER 11 DEVELOPER El TENANT
—TYPE
CONTRACTOR NAME Mark Londre
LICENSE NUMBER 591918 —714SE
c.10
BUS. LIC # 15897
COMPANY NAME Willow Glen Electric, Inc.
E-MAIL office@willowgienelectric.com
FAX (408)289-9725
STREET ADDRESS P. 0. Box 8430
CITY, STATE, ZIP San Jose, CA 95155
PHONE (408)289-9725
ARCHITECT/ENGINEER NAME N/A
LICENSE NUMBER
BUS. LIC 4
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
USE OF ;?;F;orDuplex 13 M_UIti7Farn'1y
STRUCTURE: [3 Coniniercial
PROJECT IN WILDLAND
URBAN INTERFACE AREA E] Yes Id NO
PROJECT IN
FLOOD zoNn 0 Yes 5 No
El SOLAR PANELS
I V ELECTRIC VEHICLE CHARGING STATION
WATER HEATING
❑ OTHER:
POR SOLAR PANELS: NUMBER OFPANELS/UNITS: KILOWATTS (COMMERCIAL ONLY);
TOTAL VALUATION:
Y&
DESCRIPTION OF WORK
q Circuit:
Electric Vehicle Char ginc
RECEIVED BY:
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property 4 1 havJ read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building const M ze epr res of Cupertino to enter the above -identified property for inspection purposes.
I ==
Signature of Applicant/Agent: Date:
SUPPLEMENTAL INFORMATION REQUIRED
WIcp OSE ONLY
OVIPR-T) U_-ODXJNTER
EXPRESS .
.STANDARD
.LARGE
ED MAJOR
PVApp__2011.doc revised 03116111
DocuSign Envelope ID: 40A49B23-DBOD-498F-958C-E2B738OlAl83
SMOKE / CARBON MONOXIDE ALARMS
OWNER, CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building(ftuaertino.oro
Permit No.6-2017 -0508
Address 10618 Madrid Road #of Alarms Smoke:5 Carbon Monoxide:
PERMIT CANNOT BE'FINALED AND COMPLETED UNTIL THIS CERTIFICATE
HAS LEEN SIGN ,jZ AND RETURNED TO THE BUILDING DIVISION
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and. Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for
inspections are required.
GENERAL INFORMATION
Existing single-family and .multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC ;Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon
Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s)
X
X
On every level of a dwelling unit including basements
X
X
Within each sleeping room
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms have been tested and are operational, as of the date signed
below.
r o. .. .r :,. A ..tee i., -11/ With thin tarmc anri nnnrriiiinns of this statement
r uavc rcau
m+u a .cc w w.,. ..................._ _..__--•-- --- - -
Owner (or Owner Agent's) Name:
Peter Chen
DocuSigned by:
si nalur ........Dat�017/4./
............................................................................. ................
'.... ..
Contractor Name:
3475UF4BXB03...
Signature..... ............. .......................... ....................... Lia## ...................................... Date:...................
Smoke and CO forni.doc revised 03118114
VUGUJI(yrl Crivelope lu: 4UH4`JI3L3-UCSUU-4`JLSI'-`J.7t51.-tLCS/325U IH m-5
- - _z., >
X i SMoil4
COMMUNITY DEVELOPMENT DEPARTMENT o BUILDING DIVISION
t`t1FEFtT1NO 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 - FAX (408) 777-3333 a buildinga@cupertino.om
Owner Name Peter Chen PertnitNo. 5-2017-0508
Address 10618 Madrid Road, Cupertino, CA 95014
PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE
HAS BEEN SIS= AND RETURNED TO THE BUILDING DIVISION
Please refer to the attached California Civil Code Sections 1101.1 — 1101.8 which are part of this Certification form.
1- Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101. ii through 1.101.8 do not apply. Sign below and skip the rest of the form.
Owner Signature: Date: DocuSlgned by: 2017/4/5
❑ No Go to Question 2.
E13475C2F483EB4B3
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Sign below and skip the rest of the form.
Owner' Signature: �
DocuSigned by: Date: 20 1.L7 /4/ 5
�
El No Go to Question 3. �M
! 1
3475C2F483EB4B3...
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1101. i. through 1101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature: DoeuSgnedby, Date: 2017/4/5
❑ No Go to Question 4.I Nicci(, C,�
3475CV4ME84B3...
4. is your real property built and available for use or occupancy on or before January 1, 1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
DocuSigned by:
Owner' Signature: Nv� Q*m Date: 2017/4/5
❑ Yes My real property i al<twdtweailable for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached.
❑ My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing
fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1,
2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless
of whether property undergoes alterations or improvements),
❑ My property is a multifandly residential real property. See Civil Code Section 1101.5.
On and after January 1, 20 f 4, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
SB407 2015.doc revised 02104115
DocuSign Envelope ID: 40A49B23-DBOD-498F-958C-E2B738OlAl83
CUPERTINO
SMOKE 1 CARBON MONOXIDE ALARMS
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95094-3255
(408) 777-3228 - FAX (408) 777-3333 - buildincl@cupertino.ora
Permit No.B-2017-0508
Address 10618 Madrid Road # of Alarms Smoke: 5 Carbon Monoxide: 1
PERMIT CANNOT BB FINALED AND CONTLETED UNTIL THIS CERTIFICATE
HAS BEEN SI NFD AND RR.TU NM1? TO THE BUILDING DIVISION
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and. Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for
inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC !Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon
Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s)
X
X
On every level of a dwelling unit including basements
X
X
Within each sleeping room
I X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms have been tested and are operational, as of the date signed
below.
l haves roar! and anrae to rmmnly with the terms and conditions of this statement
Owner (or Owner Agent's) Name:
DocuSigned by:
Peter Chen
Si natur ......... ..Dat 7/4%
Contractor Name:
3475C2F46XM3...
Sinature...................................................................Lic.9...................................... Date:...................
Smoke and CO form.doc revised 03118114
vvl Uu Ilyu CI IVOIVL/C w. •tvrc'tt7DCJ-UDV V-'+Zl8r-UaOl..-CL6f OOU IH 183
CUPERTINO
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT a BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3228 - FAX (408) 777-3333 a bui€dinc(a)-cupertino.orct
Owner Name Peter Chen Permit No. B-2017-0508
Address _10618 Madrid Road, Cupertino, CA 95014
i kl 1 I i.. 111 1140101 MLM In :i .! lats � o
Please refer to the attached California Civil Code Sections 1101.1 — 1101.8 which are part of this Certification form.
1. Is your real property a registered historical site'?
❑ Yes Civil Code Sections 11E01.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature: Date:
DocuSigned by: 2017/4/5
❑ No Go to Question 2.
3475C2F4B3E8483...
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
❑ Yes Civil Code Sections 110I.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Sign below and skip the rest of the form.
DocuSigned by: 2 01'9/ A /
Owner' Signature:E
���� Date: L f `t J
❑ No Go to Question 3.
3475C2F4B3EB483...
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature:DocuSigned by: Date: 2017/4/5
11 No Go to Question 4. �e%vr, Q*M
3475C2F4KE8483...
4. Is your real property built and available for use or occupancy on or before January 1, 1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
DocuSigned by:
Owner' Signature: Ne vX• 4M Date: 2017/4/5
❑ Yes My real property i iit nud> ai fable for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached.
❑ My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing
fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1,
2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless
of whether property undergoes alterations or improvements).
❑ My property is a nitiltifamily residential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
SB407 2015.doc revised 02104115
Install one 240 Volt 50 Amp dedicated circuit with a NEMA 14-50
receptacle in a weather resistant box directly next to the outdoor
main electrical panel. This circuit will provide 40 continuous amps
for EV charging. Surface -mounted 3/4" EMT w/ #6 THWN
conductors & #10 THWN ground will be used to route the circuit
from below the main electrical panel to the new NEMA 14-50
receptacle location.
NEVIA 1.. 50 ireceptacle in
Weather Ir e s i s ta In't box (N)
200A Main Ipaairrell (E)
/ 50A keireaskeit (N(
Garage
=i/ EICI..II. /
#6 11 I1 WN a: Mcairrdua:Mtors
It 10 ..II..II...i W � g ro u in d (N(
Peter Chen
10618 Madrid Road
Cupertino, CA. 95014
(408) 800-8925
CdOMMttPala11tY DEVELOPMENT ttICPPPtN
sUIId NG MoaroON_. t,u:. EIRTNO
tdi=o set of plans and sg, er cftaf ons MUST lfre kept, at the j¢
site dLU'iny ori,rSI'rCMIr r. R is it lawi`W to m alke ;any a;4'rsnges
rr,mt[MS oir ssiTiaa, or to deviate0icrofrorn, without spvfaro,
House
frcrrn the BuIIdt rc g OfffciaL
II1I°) i
Dr Y13 amw I°ii 11 n g I) e p a r
REWME'D FOR CODE CONA['[JANCE
Peter etiPage l
The staarTgair g of t1f ts iaV¢ n and a>taocificstions SIHAl L NOT t
field to ppenrrH or to f,ao „air aappprov:°ap of the violation of any
fxovision of any Comity Ordinance or State, L.aw,.
"b.:.pai Of NO }Y.�
Residential Electrical Load Calculation
Site Location:
Prepared by
Peter Chen
Willow Glen Electric, Inc.
Small -Appliance Branch Circuits [220.52(A), 210.1(C)(1)]
C E N
10618 Madrid Road
PO Box 8430IL E C T R I C
Cupertino, CA. 95014
San Jose, CA 95155 �/ p
(408) 800-8925
(408) 289-9725 - office p
General Lighting and Receptacle Loads [220.12]
3 watts per ft2 x 4,244 =
12,f 12
Small -Appliance Branch Circuits [220.52(A), 210.1(C)(1)]
1,500 watts
x 2 =
1'000
Laundry Branch Circuit(s) [220.52(6), [210.11(C)(2)]
1,500 watts
x 1 =
71.,."=s1' o
1,7,2:32
Fastened -In -Place
Appliances [220.53] Kitchen
Bath(s)
Outisde/Miscellaneous
Refrigerator(s) = 780
Instant Hot H20(s) = 480
Exhaust Fan(s)
=
Hot Tub =
Dishwasher(s) = 960
Hood Exhaust(s) =
Jacuzzi Tub(s)
= 1,920
Pool Equipment =
Garbage Disposal(s) = 600
Gas Range(s) =
Radiant Heating
=
Central Vacuum = 1,200
Microwave(s) = 1,200
Gas Oven(s) =
Steam shower
=
Sewage Ejector =
Trash Compactor =
Wine Fridge(s) =
Sauna
=
30A Circuit =
Steamer =
_
=
Garden Shed =
Total Fastened -in-place Appliance Load
7,V,4QD
Clothes Dryer(s) [220.54]
80% x
240
x
Derating
Volts
Amps
s„ III
OR
Name Plate Rating
of Clothes Dryer
= 5,000
Ranges, Ovens, Cooktops, and Other Household
Cooking Appliances [220.55]
80% x
240
x 50 =
cy 6()()
Derating
Volts
AND/OR
Name Plate Rating of Cooking Appliances
=
Heating or Air -Conditioning System (Compare the
heat and A/C, and omit the smaller.) [220.60]
Air Handler/Furnace
115
x 6.0 =
Volts
Amps
Air Conditioners
VV, "aQD
55% x
240
x 80 =
Derating
Volts
AND/OR
Name Plate Rating of Air Handler & AC Units
=
Total Volt -Ampere Demand Load [220.83]
Greater of
Air-conditioning Equipment
11,250
x 100% _
2!p1b
Electric Space Heating
-
x 100% _
First 8kVA of all other loads
8,000
x 100% =
3,fb1'b1'b
Remainder of all other loads
30,972
x 40% =
11..2, asaS
Total
311,639
Current Minimum Amperes
31,639
240 = 131 8
Current Minimum
200 Amps
(voltage) (minimum amperes)
17 Size Service or
Feeder [240.6(A)]
currently
Electric Vehicle [625.14]
125% x
240
x 48 =
14,400
Continuous Load
Volts
Amps
Minimum Amperes with Added Load
Minimum Size
Divide the total 4E6,039
240 = 1911 8
Service or Feeder
200 Amps
volt-amperes by
(voltage) (minimum amperes)
20
w/ Added Load
with added load
the voltage.
[240.6(A)]
NOTES
All References are to 2014 National Electrical Code.
II1I°)EI1111 "
SII° a l° �I d li ui;° I) e p a rtau m e rs
REW.W.1) FOR CODE CONA['[JANCE
Data: 3/;'wig/l
INSTALLING YOUR 240 VOLT OUTLET
The recommended home charging installation for Tesla vehicles is a 240 volt NEMA 14-
50 outlet. This outlet is commonly used for electric ranges and large recreational
vehicles. Installed with a 50 -amp circuit breaker, this outlet enables a recharge rate of
about 25 miles per hour.
Consult a licensed electrician to review the electrical load of your home prior to
installation. They will design your charging system and obtain a permit for a general
purpose NEMA 14-50 outlet from your local building department. After installation, the
electrician will schedule an inspection to approve the new electrical circuit and design.
This guide provides reference for specifications to install this outlet. Since each
installation is custom to the home, all hardware for the NEMA 14-50 outlet will be
provided by your electrician.
GIROUNDTO TOP NEMA 14-50 DETAILS
Volltage:: Single phase, 208-250 volt AC supply, 60 hertz
Circuit Breaker:: 50 amp (125% overcurrent protection)
G, Operating Cuinreint:: 40 amp (maximum continuous current)
250V Conductors:: 6 AWG, Copper Wire Only, Upsize wiring for installations over 150 feet
Ground IFaullt Circuit lintenrulpteir:: Not required
Service Disconnect:: Not required
RecelptacIle Recomirneindiatiom: High quality, industrial grade receptacle
Examples: Hubbell part# FlIBIL940A, Cooper part #5754 1
Ventillatiom: Not required
Outdoors:: Install with NEMA 3R rainproof enclosure
RECOMMENDED LOCATIONS
ADDITIONAL RESOURCES
EMAIL
0 1AR:GH',1G1NS-1 /Id..F /\-T ONJ(eb I I S1 /11.0011-1
PHONE
650.681.6133 (IM F)
24/7 TECH SUPPORT
877.798.3752
WEB
CHARGE P(JR"r CU�II�qBIWHWBTORE
1111� ufldingbio-�a IiWe�hf- M
RIl,"COMMEINIDCF0
ED LOATION ORI 24 V -El'
IaEW..Wl..[) FOli COD�- C&MI3[.WCE
o3evuewed 13yAbby Ayande
T =— Ei I– Fi Date: 03/K/l 7 45500 Fremont Boulevard, Fremont, CA 94538 1 May, 2016 1 Version 3