11050046CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10336 VICKSBURG DR
O` " FR'S NAME: WM R & LISA K CROOKE
4R'S PHONE: 4082345782
❑ LICENSED CONTRACTOR'S DECLARATION
License Class ic. # G Ln37 77 3
Contractor f��Date 21-C3— t
hereby affirm that 1 am licensed under the provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
1 hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulatiot er the Cupertino Municipal Code, Section
9.18,
Sienatur Date
OWNER-BUILDER DECLARATION
1 hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
I, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project (Sec.7044, Business & Professions Code).
1 hereby affirm under penalty of perjury one of the following three
declarations:
I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
CONTRACTOR: LYNSTAR ENTERPRISES
INC.
418 SOUTH 15TH ST.
PERMIT NO: 11050046
DATE ISSUED: 08/09/2011
SAN .LOSE, CA 95112 � PHONE NO: (408)280-1848
BUILDING PERMIT INFO: BLDG ELECT PLUMB r
MECH r RESIDENTIAL r- COMMERCIAL
permit is issued.
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
become subject to the Worker's Compensation provisions of the Labor Code, I must
forthwith comply with such provisions or this permit shall be deemed revoked.
APPLICANT CERTIFICATION
JOB DESCRIPTION: ADD(554 SQFT)LIVING RM,ENTRY,FRONT & REAR
PORCH,
ATTACHED GARAGAE (431 SQFT) REMODEL 1805' NEW HIP
ROOF OVER (E) STRUCTURE,KITCHEN, BATH, NEW
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
nify and keep harmless the City of Cupertino against liabilities, judgments,
and expenses which may accrue against said City in consequence of the
'Jig of this permit. Additionally, the applicant understands and will comply
.dl non -point source regulations per the Cupertino Municipal Code, Section
9.18.
Signature Date
Sq. Ft Floor Area: I Valuation: $300000
APN Number: 36914003.00 I Occupancy Type:
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS FROM LAST CALLED INSPECTION.
ate— —
Issued �-� - Date:�-
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature of Applicant:_ Date
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
HAZARDOUS MATERIALS DISCLOSURE,
have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain
compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health &
Safety Code, Section 25532(a) should 1 store or handle hazardous material.
Additionally, should I use equipment or devices which emit hazardous air
contaminants as defined by the Bay Area Air Quality Management District I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety C-oge, Sections 25505, 25533, and 25534.
Own r or a ortzetl agent:
-� Date:
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of %%ork's
for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Licensed Professional
CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10336 VICKSBURG DR
CONTRACTOR. LY11STAR ENTERPRISES
PERMIT NO: 11050046
INC.
OWNER'S NAME: WM R & LISA K CROOKE
418 SOUTH 15TH ST.
DATE ISSUED: 08109/2011
OWNER'S PHONE: 4082345782
SAN JOSE, CA 95112
PHONE NO: (408)280.1848
❑ LICENSED CONTRACTOR'S DECLARATION
f—
PERMIT INFO: BLDG PLUMB
{� �7 �7 -7
License Class 1�) ic.4 S �J ! [ 3
BUILDING ELECT
MECH
G n r
Contractor Date G` �l� {i
RESIDENTIAL COMMERCIAL
1 hereby affirm that 1 am licensed under the provisions of Chapter 9
JOB DESCRIPTION: ADD(554 SQFT)LIVING RM,ENTRY,FRONT & REAR
(commencing with Section 7000) of Division 3 of the Business & Professions
PORCH,
ATTACHED GARAGAE (431 SQFT) REMODEL 1805' NEW HIP
Code and that my license is in full force and effect.
ROOF OVER (E) STRUCTURE,KITCHEN, BATH, NEW
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Cade, for the performance of the work for which this
Sq. Ft Floor Arca:
Valuation: $300000
permit is issued.
APPLICANT CERTIFICATION
APN Number: 36914003.00
Occupancy Type:
1 certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
PERMIT EXPIRES IF WORK IS NOT STARTED
costs, and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally, the applicant understands and will comply
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
with all non-point source regula(icx er the Cupertino Municipal Code, Section
180 DAYS FROM LAST CALLED INSPECTION.
9.18.
Signatur Date S;L
Issued 4 Date:
❑ OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of
RE-ROOFS:
the following two reasons:
All roofs shall be inspected prior to any roofing material being installed. if a roof is
I, as owner of the property, or my employees with wages as their sole compensation,
installed without first obtaining an inspection, I agree to remove all new materials for
will do the work, and the structure is not intended or offered for sale (Sec.7044,
inspection.
Business & Professions Code)
1, as owner of the property, am exclusively contracting with licensed contractors to
Signature of Applicant: Date:
:onstruct the project (Sec.7044, Business & Professions Code).
[ hereby allirm under penalty of perjury one of the following three
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
declarations.
I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
HAZARDOUS MATERIALS DISCLOSURE
performance of the work for which this permit is issued.
I have read the hazardous materials requirements under Chapter 6.95 of the
I have and will maintain Worker's Compensation Insurance, as provided for by
California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain
Section 3700 of the Labor Code, For the performance ofthe work for which this
compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health &
Safety Code, Section 25532(x) should 1 store or handle hazardous material.
permit is issued.
Additionally, should I use equipment or devices which emit hazardous air
I certify that in the performance ofthe work forwhich this permit is issued, I shall
contaminants as defined by the Bay Area Air Quality Management District I will
not employ any person in any manner so as to become subject to the Worker's
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
compensation laws of California. If, after making this certificate of exemption, I
Health& Sa ety e. Sections 25505, 25533, and 25534.
mecome subject to the Worker's Compensation provisions ofthe Labor Code, I must
Forthwith comply with such provisions or this permit shall be deemed revoked.
Own r or a orize agent: r
Date-
APPLICANT CERTIFICATION
CONSTRUCTION LENDING AGENCY
certify that I have read this application and state (hat the above information is
;ofrect. 1 agree to comply with all city and county ordinances and state laws relating
I hereby affirm that there is a Wnstruction lending agency for the performance of Mork's
o building construetkm, and hereby authorize representatives of this city to enter
for which this permit is issued (See. 3097, Civ C.)
ipon the above mentioned property for inspection purposes. (We) agree to save
Lender's Name
ndemnify and keep harmless the City of Cupertino against liabilities, judgments,
'osts, and expenses which may accrue against said City in consequence of the
Lender's Address
;ranting of this permit. Additionally, the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code, Section
ARCHITECT'S DECLARATION
3.18.
1 understand my plans shall be used as public records.
signature Date
Licensed Professional
CUPERTINO
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 w building(a�cupertino.orp
/ivy oof�
❑ NEW CONS'T'RUCTION X ADDITION ❑ ALTERATION I TI ❑ REVISION /DEFERRED ORIGINAI, PERMIT #
PROJECTADDRESS ! O ✓3 /V•y ` r f1 U 01L.
APN • j,�� . �02
n
W %
OWNER NAME r u�d h{
r
AIk
PHONE /f' E-MAIL)
"��illl•�
STRESI'ADDRESS
DR,
Crl"Y, STATE, ZIP �
�JV!
FAX
CONTACT NAME �� �-
PHONE /'45A.� qq f /'Q�0
f( jpL1VL
E-MAIL
STREET ADDRESS � 0 [� L. ,y `', NTP
CITY, STATE, ZIP / /� jl Vqo
_OS
FAX
❑ OWNER ❑ OWNERd51-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT X ARCnTTECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
BCACTOR NAME
LICENSE NUMBER
LICENSE TYPE BUS LIC H
COMPANY NAME
E-MAIL FAX
STREET ADDRESS
CtFY, STATE,ZIP PHONE
ARCHITECIYEEyG[N •E NAMFFj�
LICENSE NUMBER BUS. LIC H
STREETAI)DWL
4J :T;kZ� (:A,':;t G.Z
DESCRIPTION OF WORK L1
V1C-0 VeA W F/XW
avec Sr C� _�8O3.7S fit) tieLi (telwo-B
12,&i,A � L V t.- r -H 910 ( 2 tom- R A *3 C v2 V /20 L0 0/re L"
EXtSTIN'i UE
PROPOSED USE
•✓ ]
CO,NSSTR. TYPE
+a
OSTORIFS
OF -E USE ONLY
�✓���
`
OAJE
OCC
TYPE
DESCRIPTION
SOFT
VALUATION
EXISTG
r
Q
NEW PI.C"'-' DEMO
G�
4, 5
TOTAL �g S
V
'3
AREA
AREA j AREA 13+0
NET AREA
BATHROOM
� 011
N OTHER
� �
� �
REMODEL AREA
REMODEL AREA � REMODEL AREA
nnRCU AREA HECK gRk.A TOTAL bECK/Pt1Rr'11 AREA G GE AREA: El DETACH
f TACH
I DWELLING AMTS I lSASCCOND r1Nrr ❑YES SECOND STORY ❑YEA
6EINGADOFD? A➢➢]TION? ❑ --
NII -APPLICATION ❑ •.
W YE5, PROVIDE COPY OF
PI.ANNEWSNAMF.:
RGCEFVED BY. `
TOTAL VALUATIp1E,
K
PLANNING Al". d ❑ NO
PLANNING APPROVAL LI:TFER
/CJY'7J
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. 1 have read this
application and the information I have provided is et. I have read the Description of Work and verify it is aeeurate. I agree to comply with all applicable local
ordinances and state laws relating t ufltrue on. [ authorize representatives of Cupertino to enter the above -identified property for inspection purposes.
Signature of Applican en Date: 5 -If " i
SUPPLEMENTAL INFORMATION REQUIRED
PLAN CHECK TYPE
ROUTING SLIP
IJ OVER-THIrCOUNTER
���
6UILDING PLAN REVIEW
New SFD or Multifamily dwellings: Apply for demolition permit for
existing building(s). Demolition permit is required prior to issuance of building
for building.
❑
permit new
EXPRESSP�NG
PLAN REVIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
TANDARD
C WORKS
form if any Hazardous Materials arc being used as part of this project.
❑ LARGE.
'IRE DEPT
Copy of Planning Approval Letter or Meeting with Planning prior to
C1 MAJOR
ANITAAY SEWER DISTRICT'
submittal of Building Permit application.
D ENVIRONMENTAL HEALTH
81dgApp_201 ].doe revised 03/16/11
9
CITY OF CUPERTINO
FEE ESTIMATOR - BUILDING DIVISION
ADDRESS: 10336 vicksburg dr.
DATE: 0 510 912 01 1
REVIEWED BY: bobs.
APN:
BP#:'
`BP EES
"VALUATION: $300,000
'PERMIT TYPE: Building Permit
PLAN CHECK TYPE:
Addition
PRIMARY SFD or Du lex 2nd Unit?
USE: p OTC?
Yes No
® Yes G No
PENTAMATION 1 R3SFDADD
PERMIT TYPE:
WORK sfd add living,front and rear porch, new hip and gable roof, skylights,
replace windows non structural
SCOPE add furnace at attic location, service upgrade.
$0.00
OCCUPANCY TYPE:
TYPE OF
CONSTR.
FLR AREA
s.f.
PC FEES
PC FEE \ID k
`BP EES
BP FEE ID
R-3 (Custom)
11-B,111-B,IV,V-B
985
$2,349.00
IR3PLNCK
$1,474.00
IR3INSP
t i('r'. rnnp. T.yW_
$0.00
Permit Fee:
$1,474.00
Suppl. Insp. Fee -.0 Reg.
0 OT
1 0.0
1 hrs
$0.00
PME Unit Fee:
$0.00
PMEPermitFee:
$0.00
TOTALS:
F 985
$2,349.00
lJ
F:L ,,iu"7 1 ./7"4
$1,474.00
MECH, HOURLY 0 Yes G No
PLUMB, HOURLY Q Yes Q No
ELEC, HOURLY Q Yes Q No
P17", , I../?2_k
Pl&n
Plan Check Fee:
$2,349.00
1,804 s.f. Remodel, Other Rvilel"Imlk
$4,573.00 IREMRESZ
W .¢�r:.11..":.Yr9_
t.)s1le.l• j�ll4istll if=Jl;,
f)'i1G' aic:. ri1sjA
1 hrs
IrF", Fee:
t i('r'. rnnp. T.yW_
NOTE: These fees are based on the Ureliminary information available and are only an estimate. Contact fire Dent for addn'l info.
FEE ITEMS (Fee Resolution 04-051 Eff. 7/I1'10}
FEE
QTYIFEE
MISC ITEMS
14
Plan Check Fee:
$2,349.00
1,804 s.f. Remodel, Other Rvilel"Imlk
$4,573.00 IREMRESZ
Suppl. PC Fee: G Reg. O OT
1 0.0
1 hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$1,474.00
Suppl. Insp. Fee -.0 Reg.
0 OT
1 0.0
1 hrs
$0.00
PME Unit Fee:
$0.00
PMEPermitFee:
$0.00
lJ
F:L ,,iu"7 1 ./7"4
Acoustical Fee:
O Yes (D No
$0.00
Q
E)
Work Without Permit? 0 Yes G No
$0.00
Plannine Fee:
PLLONGRNGR
$128.05
Select a Non -Residential
Building or Structure
0
O
14
1 i ctl%;'%_7(.1C;ii7c'•'1x:rt1C317 e.'
l'e.i;
Strong Motion Fee:
1RSEISMICR
$30.00
Select an Administrative Item
Bldg] Stds Commission Fee: IRCRSC
$12.00
SUBTOTALS: j
$3,993.05
$4,573.00
TOTAL FEE:
F $8,566.05
Revised: 0412 912 01 1
1 ;-
BUILDING ENERGY ANALY,SISv'REPORT
Ci
SUBMITTAL
#2�.
PROJECT:
Crooke Addition
10336 Vicksburg Drive
Cupertino, CA 95014
Project Designer:
Chapman Design Associates
620 S. EI Monte Avenue
Los Altos, CA 94022
(650) 941-6890
Report Prepared by:
Heather Clark, CEPE
Builders' Energy Services
1478 Bird Ave
San Jose, CA 95125
(408) 202-9075
r�
BUILDER'S
ENERGY
SERVICES
110-5-00010
Job Number:
05041 R 1 R ; �111O •
Date: JUL 2 5 2011
7/15/2011,F\IIE-\N�1D
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
1R1
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -IR Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
EnergyPro 5.1 by Energy5oft Job Number. ID: 05041R1 User Number. 1239
2
3
10
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
Crooke Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/16/2011
Project Address
10336 Vicksburg Drive Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area
2,280
Addition
476
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features (see Part 2 of 5) Status
Wall Wood Framed
None 1,131 Existing
Floor Wood Framed w/Crawl Space
None 1,804 Existing
Roof Wood Framed Athe
R-11 1,439 Existing
well Wood Framed
R-13 515 New
Floor Wood Framed w/Crawl Space
R-19 476 New
Roof Wood Framed Rafter
R-19 358 New
Roof Wood Framed Attic
R-30 476 New
Door Opaque Door
None 18 New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (N) 72.0 0.580
0.65 none none Bug Screen New
Left (E) 10.6 0.580
0.65 none none Bug Screen Altered
Rear (S) 64.0 0.580
0.65 none none Bug Screen Altered
Rear (S) 96.0 0.530
a65 none none Bug Screen New
Rear (S) 22.5 a580
0.65 none none Bug Screen New
Right (W) 80.0 0.530
0.65 none none Bug Screen New
Right (W) 15.0 0.580
0.65 none none Bug Screen New
Skylight 7.4 0.390
0.29 none none None New
Front (N) 13.4 0.580
0.65 none none Bug Screen New
Left (E) 30.0 0.580
0.65 none none Bug Screen New
Left (E) 8.4 0.580
0.65 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80%AFUE Split Air Conditioner 13.0 SEER Setback
Altered
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
Existing Forced Air Ducted
Ducted Attic, Ceiling Ins, vented 6.0 Altered
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
I Instant Gas 0
0.84 No Pipe Insulation Altered
EnergyPro 5, 1 by EnerqySoft User Number. 1239 RunCode: 2011-07-15T11:39.36 ID: 050411 1
Page 3 of 12
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
Crooke Addition
Building type ® single Family ❑ Addition Alone
❑ Multi Family ® Existing+Addition/Alteration
hate
7/15/2011
Project Address
10336 Vicksburg Drive Cupertino
California Energy Climate Zone Total Cond. Floor Area
CA Climate Zone 04 2,280
Addition
1 476
If of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (fly Features (see Part 2 of 5) Status
FENESTRATION U- Exterior
Orientation Area(fl) Factor SHGC Overhang Sidefins Shades Status
Left (E) 10.8 0.580 0.65 none none Bug Screen New
Right (tM 30.0 0.580 0.65 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnerqySoft User Number 1239 RunCode: 2011-07-15711:39:35 ID_ 05041R1
Page 4 of 12
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R
Project Name
Crooke Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
7115512011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a buitding or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-411 form for each of the measures listed below for final to be given.
EnatgyPro 5.1 by EnerqySoft User Number. 1239 RunCode: 2011-07-15Ti1:39:36 0: 05041R1 Pa e 5 of 12
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CFA R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Crooke Addition
❑ Multi Family 10 Existing+ Addition/Alteration
7/152011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kStulft2- r
Space Heating 76.47 51.90 24.58
Space Cooling 60.13 40.89 19.24
Fans 20.78 16.79 4.00
Domestic Hot Water 19.73 13.60 6.13
Pumps 0.00 0.00 0.00
Totals 177.12 123.18 53.94
Percent Better Than Standard: 30.5%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 342 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 506 85
Fuel Available at Site: Natural Gas (E) 527 60
Raised Floor Area: 2.280 (s) 554 183
Slab on Grade Area: 0 (00 529 125
Average Ceiling Height: 9.2 Root 2,280 7
Fenestration Average U -Factor: 0.56 TOTAL: 460
Average SHGC: 0.65 Fenestration/CFA Ratio: 20.2%
REMARKS
11,07.14- Reflects revisions required as a result of liquefaction issues.
STATEMENT OF COMPLIANCE
CEDE #
R-08-01-1860
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
LABEC
Efficiency Standards of the California Code of Regulations.
Heather Clark
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Builders' Energy Services~--
7/15201 i
Address 1478 Bird Ave Name Heather Claris, CEPS
Uy/State/ZipUy/State/Zip San Jose, CA 95125 Phone (408) 202-9075 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Chapman Design Associates
Address 620 S. El Monte Avenue Name Walter Chapman
City/State/zip Los Altos, CA 94022 Phone (650) 941-6890 Signed License # Date
EnemvPro 5. 1 by EnergySoft user Number. 1239 RunCode. 2011-07-15T11.39.36 lb: 05041R1 Page 6 ot12
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5) CF -1 R
Project Name
Crooke Addition
Building Type m Single Family ❑Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7115/2011
OPAQUE SURFACE DETAILS
Surface
Type Area
Insulation Joint Appendix
CavityExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Wall
159
None
EO.356
342 90 Existing4.3.1-A1
Existing House
Wall
14$
None
342 90 Remove 4.3. i A 1
Existing House
Door
20None
342 90 Remove 4.5.1A4
Existin House
Wall
417.
None
72 90 Existing 4.3.1 Al
Existing House
Wall
277
0.356 None
162 90 Existing 4.3.1A1
Existing House
Wall
2781
0.356 None
252 90 Existing 4.3.1 -Ai
Existing House
Wall
501
0.356 None
252 90 Removec 4.3.1 -Ai
Existing House
Floor
1,80411
0.097 None
0 180 Existing 4.4.1 -Ai
Existing House
Roof
1,439
0.079 R-11
342 0 Existin 4.2.1-A2
Existing House
Roof
358
0.079 R-11
342 0 Remove 42.1-A2
Existing House
Wall
73
0.102 R-13
342 90 New 4.3.1 A3
Existing House
Wall
50
0.102 R-13
72 90 New 4.3.1 A3
Existing House
well
95
0.102 R-13
162 90 New 4,3,1-A3
Existing House
Wall
126
0.102 R-13
252 90 New 4.3.1-A3
Existing House
Floor
476
0.037 R-19
0 180 New 4.4.1-A4
isfing House
Roof
1791
0.051 R-19
72 23 New 4.2.2-A 12
lExisfing House
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor T
SHGC2
Azm Status Glazing Type
Location/Comments
1
Window
30.4 1.280 Default
0.80 Default
342 Removed 80310 - Slider
Existing House
2
Window
30.4 1.280 Default
0.80 Default
342 Removed 80310 - Slider
Existing House
3
Wrndow
36.0 0.580 Default
0.65 Default
342 New 8046 - Slider
Existing House
4
Window
36.0 0.580 Default
0.65 Default
342 New 8046 - Slider
Existing House
5
Window
6.7 1.280 Default
0.80 Default
342 Removed Sidelight
Existing House
6
Window
6.7 1.280 Default
0.80 Default
342 Removed Sidelight
Existing House
7
Window
64.0 1.280 Default
0.80 Default
342 Removed 8080 - Slider
Existing House
8
Wrndow
10.6 0.580 1 Default
0.65 Default
72 Altered New 8080 - Slider
Existing House
9
Existing
1.280 Default
0.80 Default
310210 - Slider
pre -altered for above
10
Window
10.6 1,280 Default
0.80 Default
72 Removed 310210- Slider
Existing House
11
Window
10.6 1.280 Default
0.80 Default
72 Removed 310210 - Slider
Existing House
12
Window
64.0 0.580 Default
0.65 Default
162 Altered New 8080 - Slider
Existing House
13
Existing
1.280 Default
0.80 Default
8080 - Slider
pre -altered for above
14
Window
64.0 1.280 Default
0.80 Default
1621 Removed 8080 - Slider
Existing House
15
JWndow
30-01 1.280 1 Default
0.80 Default
1621 Removed 5060 - Slider
Existing House
16
11,46ndow 1
64.01 1.280 1 Default
0.80 Default
1621 Removed 8080 - Slider
ExistingHouse
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H91 Wd
Ove hang Left Fin Right Fin
Len H t LEA REA Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bua Screen
0.76
10
Bug Screen
0.76
I 1
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
IBug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number. 1239 RunCode: 2011-07-15T11.3916 1D: 05041R1
Page 7 of 12
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Crooke Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ AdditionlAlteration
Date
7115/2011
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 LocationlComments
Roof
179 0.051 R-19
252 23 New 4.2.2-A 12
Existing House
Roof
476 0.031 R-30
342 0 New 4.2.1 A20
Existing House
Wall
171 0.102 R-13
342 90 New 4.3.1 A3
Existing House
Door
18 0.500 None
342 90 New 4.5. i -A4
Existing House
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGG2
Azm Status Glazing Type
Location/Comments
17
Window 96.0
0.530 Default
0.65 Default
162 New 12080 - Slider
Existing House
18
Window 22.5
0.580 Default
D.65 Default
162 New 5046 - Slider
Existing House
19
Window 14.4
1.280 Default
0.80 Default
252 Removed 310310 - Slider
Existing House
20
Window 80.0
0.530 Default
0.65 Default
252 New 10080 - Slider
Existing House
21
Window 15.0
0.580 Default
0.65 Default
252 New 3050 - Casement
Existing House
22
Window 14.4
1.280 Default
0.80 Default
252 Removed 1310310 - Slider
Existing House
23
Skylight 7.4
0.390 NFRC
0.29 NFRC
342 New Velux Comfort+(74) LoweglArg
Existing House
24
Window 6.7 1
0.580 Default
0.65 Default
342 New New Sidelight
Existing House
25
Window 6,7'
0.580 Default
0.65 Default
342 New New Sidelight
Existing House
26
Window 30.0
0.580 Default
0.65 Default
72 New 6050 - Casement
Existing House
27
Window 8.4
0.580 Default
0.65 Default
72 New 30210 - Slider
Existing House
28
Window 5.4
0.580 Default
0.65 Default
72 New 2424 - Casement
Existing House
29
Window 5.4
0.580 Default
0.65 Default
721 New 2424 - Casement
Existing House
30
Window 30.0
0.580 Default
0-65 Default
2521 New 6050 - Slider
Existing House
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRG = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len Hot I LExt RExt Dist Len H t Dist Len Hot
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
None
1.00
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
EnemyPro
5.1 by EnergySoft
User Number.- 1239 RunCode: 2011-07-15T11:39.36 ID: 05041 R1
Pae 8 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Crooke Addition
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
711512011
BUILDING ZONE INFORMATION
System Name
Floor Area
Zone Name New Existin_o Altered Removed Volume Year Built
Existing Forced Air
1st Floor 1,804
18,236 9968
New 1st Floor 476
4,760
Totals 476 1,804 0 01
1
HVAC SYSTEMS
System Name
Heating Type Min. Eff. Cooling Type Min. Eff_ Thermostat Type Status
Existing Forced Air
1 Central Furnace 80%AFUE Split Air Conditioner 13.0 SEER Setback
Altered
pre -altered for above
Central Furnace 76% AFUE Split Air Conditioner 10.0 SEER Setback
HVAC DISTRIBUTION
S stem Name
Duct
Heating Cooling Duct Location R -Value
Ducts
Tested? Status
Existing Forced Air
Ducted Ducted Attic, Ceiling Ins, vented 6.0
❑ Altered
pre -altered for above
Ducted Ducted Attic, Ceiling Ins, vented 2.1
❑
WATER HEATING SYSTEMS
S stem Name
Type
Rated
Input
Distribution Btuh
Tank Energy
Cap. Factor
al or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Generic Tankless
1
Instant Gas
No Pipe Insulation 185,000
0 0.84
n1a
n1a
Altered
Default Gas Prior to 1999
1
Smail Gas
pre -altered for Above 26,000
50 0.53
Ma
n1a
MULTI -FAMILY WATER
HEATING DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
�
0
ro
v
¢ 9
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Oty. HP
Plenum Outside Buried
EnergyPro 5.1 by EnergySoft
User Number. 1239 RunCode: 2011-07-15T11:39:36 ID: 05041R1
pa5e 9 of i2
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Crooke Addition
Date
7/15/2011
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used_ More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage -
eaka e_§116(a)4:
§1 16(a)4:Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and seated.
118 a : Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §11 B(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
_*§150(c): Minimum R-13 insulation in wood -frame wall orequivalent LI -factor.
150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f). Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form_
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150(e)1A.- Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)i B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§ 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydropic heating systems or hot water systems X15 psi, meets the requirements of Standards Table
123-A.
150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1 500)3A: insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 4. Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySott User Number.- 1239 RunCode: 2011-07-15Ti1:39:36 ID: 05041R Page i0 of r2
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Crooke Addition
7/15/2011
§150(m)1. All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts_
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tae is used in combination with mastic and draw bands.
150 (m)7: Exhaust fans stems have back draft or automatic dam ers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have orous inner cores.
§150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating -
eatin _114
§1 14b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2-
0 k 2_150
§1 50k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k),
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ftz may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
Luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoff User Number- 1239 RunCode: 2011-07-15rl1.39:36 !D: 05041R1 Page 11 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Crooke Addition
711-':V2011
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION is Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not re wired to comply with §15Q k 11.
§150(k)12. Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16. Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPna5.1 byEnengy5oft User Number. 1239 RurrCode:2011-07-1STI 1:38:36 ID: 0504 IRI Page f2 of f2