Loading...
14050045CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22430 CUPERTINO RD CONTRACTOR: NEKO ELECTRIC PERMIT NO: 14050045 OWNER'S NAME: ALI PAKNAHAL & MESBAHI MOTAHAREH 22430 CUPERTINO RD DATE ISSUED: 03/27/2015 OWNER'S PHONE: 4084464141 CUPERTINO, CA 95014 PHONE NO: (408) 446-4141 ?1181LICENSED CONTRACTOR'S DECLARATION r� JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL ❑ 2 SQ FT ADDITION TO SFDWL, 200 SQ FT GARAGE AND License Class Lic. # 3 - REMODEL 825 SQ FT THROUGH OUT, 200 AMP PANEL N y$' //L% C Date UPGRADE Contractor I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's mpensation, as provided for by Section 3700 of the Labor Code, for the p ormance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $695675 ave and will maintain Worker's Compensation Insurance, as provided for by APN Number: 32650070.00 Occupancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter SPECTION. upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Issu Date: granting of this permit. the applicant understands and will comply with all n source regulations per Cupertino Municipal Code, Section RE-ROOFS: 9Cature? S Date 7- I J All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(x) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Management District I performance of the work for which this permit is issued. will maintain compliance with t ertino Mal Counicipe, ter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, ions 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this —7 Owner or authorized a nt: : 3 permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address - I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date 15 CONSTRUCTION PERMIT APPLICATION �� COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISIO � 10300 TORRE AVENUE - CUPERTINO, CA 86014.3266 I- (408) 777-3228 - FAX 408 777-3333 - buildin CUPERTINO ( ) g0cuoertino.org ❑ NEW CONSTRUCTION ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS r/j���ryj^�j^ _ 7 APN # �U ^ OWNER NAM MOTNHAR1EPHONE .' E -M IL C STRI;�14$$, 5 r''^ ,STATE, ZIP _ _ - FAX R ^ � CONTACT NAME�l - NE — MAL VG` r C" 1 STREET ADDRESS CITY, STATE, ZIP_11AX Ti �) ^ O 72, 1 ❑ OWNER ❑ OWNER -BUILDER V OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ,0,11611JINEER DONE N�1A JU { LICENSE NUMBER BUS. LIC # COMPANY NAE LrN E-MAIL FAX STS ADDRESS �� CC ,STATE, ZIP S 1 � PHONE ; - `J DESCRIPTION OF WORK 00 (_ 2-dc3 1 &A)QAQF_ AJ1Qe.J6-%AWGiuvqrtk 20AAp EXISTING USE ,. su PROPOSED USE CONSTR. QE �, TYPE `'tZ, v ✓TOTAL # STORDiS I 1 USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR AREA - �� AREA (� ' DEMO AREA NET AREA %7 /' _ I I (flp ` t �{� V LJ f ��„� n 2B j U 7c, BATHROOM REMODEL AREA �IEECKSl KITCHEN REMODEL AREA .4(5® OTHER REMODEL AREA ^ PORCH AREA ISE)I(i✓ TOTAL DECK/PORCH AREA N� �-j GAR A::[IrDETTAACH TTACH # DWELLING UMTS: IS A SECOND UNIT �❑ s BEING ADDED? SECOND STORY ❑ YES ADDITION? �o A'_ PRE -APPLICATION YES IF YES, PROVIDE CggPV OF PLANNING APPL # ❑ NO PLANN IF LETTER `e IS THE BLDG AN ❑ YES EICHLER HOME? �1pI�N0 RECEIVED BY: TOTAL VALUATION: � -79 By my signature below, I certify to e ch o following: I am the property owner or authorized agent to act on the property owner's behalf. I have lead this application and the information I h e provided is correct. I have read the Description of Work and v ' - it is accurate. I agree to comply with all applicable local ordinances and state laws relating to bu* c nstr I authorizer entatly Ino to enter the above -identified property f r inspection purposes. Signature of Applicant/Agent Date: SUPPLENWNTAL INF01WATION REQUIRED PLAN CHECK TYPE ROUTING SLIP ❑ OVER-THE-COUNTER ❑ BUILDING PLAN REVIEW New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ ❑ LARGE FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp 2011.doc revised 06/21/11 rr.�,�..--����:..����1 CITY OF CUPERTINO Fia—m—l7l -92490VF.1W FCTI<MATnR — RITILDING DIVISION PilADDRESS: 22*Wcuprtino rd DATE: 05/06/2014 REVIEWED BY: MENDEZ PC FEE ID APN: BP#: "VALUATION: $695,675 2,012 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY USE: SFD or Duplex 2nd Unit? 0 Yes No OTC? 0 Yes No PENTAMATION 1 R3SFDADD PERMIT TYPE: i WORK 11812 sq ft addition to sfdwl 200 sq ft garage and remodel 825 sq ft through out 200 amp panel SCOPE I upgrade OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,111-B,IV,V-B 2,012 $2,797.33 IR3PLNCK $2,406.25 IRMATSP PME Plan Check: $0.00200 amps $47.00 Electrical IBELEC2007 Services Permit Fee: $2,406.25 Suppl. Insp. Fee -0 Reg. Q OT 0.0 lirs $0.00 PME Unit Fee: $0.00 PME Permit Fee:$47.00 TOTALS: 2,012 $2,797.33 $2,406.25 MECH, HOURLY ® Yes E) No PLUMB, HOURLY Q Yes Q No ELEC, HOURLY O Yes Q No MISC ITEMS Elec. Plan Check 0.0 1 hrs $0.00 $2,797.33 F-8257 s.f. $558.00 Elec. Permit Fee: IEPERMIT Suppl. PC Fee: Q Rcg. Q 01' Other Elec. Insp. 0.0 �rs$47.00 hrs $0.00 PME Plan Check: $0.00200 amps $47.00 Electrical IBELEC2007 Services NOTE: This estimate does not include fees due to other Departments (i.e. Manning, ruouc rvorKs, mere, ouRuury serve. Lwu�u, �a .. w. bd #1.l' ina in ormation available and are onl an estimate. Contact the De t or addn'l in o. Dtstrict, eta . These ees are as on a re tm FEE ITEMS (Fee Resolution 11-053 Eff. 7/1113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,797.33 F-8257 s.f. $558.00 Remodel, Other 1REMRESOTH Suppl. PC Fee: Q Rcg. Q 01' 0.0 hrs $0.00 PME Plan Check: $0.00200 amps $47.00 Electrical IBELEC2007 Services Permit Fee: $2,406.25 Suppl. Insp. Fee -0 Reg. Q OT 0.0 lirs $0.00 PME Unit Fee: $0.00 PME Permit Fee:$47.00 7"71'." F O 0 Work Without Permit? Yes 0 No $0.00 Advanced Planning Fee: IPLLONGR $281.68 Select a Non -Residential Building or Structure Q Travel Documentation Fee: 1TRAVDOC $47.00 Strong Motion Fee: 1BSEISMICR $69.57 Select an Administrative Item Bldp, Stds Commission Fee: IBCBSC $28.00 SUBTOTALS: $5,676.83 $605.00 TOTAL FEE: $6,281.83 Revised: 04/01/2014 CUPERTINO CONTRACTOR / SUBCONTRACTOR LIST Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 JOB ADDRESS: ,'L 3 v C a e r LTJ b PERMIT # 1 D 5 D OWNER'S NAME: L.c, rAk A,,-*,4j0r-,4 PHONE # d 3 GENERAL CONTRACTOR: U w`t't % v0'V tiBUSINESS LICENSE # ADDRESS: 2 o LSC er i),7 O kd CUP-erf4l;�o CITY/ZIPCODE: 5 D L *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Please check applicable subcontractors and complete the following information: Date V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Z De 5/1 27 Co ry� . ru L�� o yj 1 D v 1°17 Cement Finishing Electrical /4/V S l y1 G NJ d e C L C <5 3 TtE 3 �((p Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing (,( r G L 5-9 C—! 7- 6 3 3 8 Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing C L (,L')yl b 1' r» Ll C . q335 15 Roofing Septic Tank Sheet Metal Sheet Rock Tile 9r/ Owner / Contractor Signature Date 1o' Mev J 11 RECEIVED COPY Ci SEP 0 9 2014 CALIFORNIA ENERGY COMIVII SII TITLE 24 CALCULATIONS AND DOC NTAMN- 4 /`fo500y� �AHAL RESIDENCE �UPERTINO ROAD ERTINQ CALIFORNIA CUPERTINO aBuilding Department DEC 05 2014 PEVIEVAIEU rUR COUE COMPLIANCE r-<UV1dYVe ] tiy• Prepared by Yarmila Kennett & Associates Certified Energy Analyst Certified Energy Plans Examiner Certified GreenPoint Advisor & Rater Build It Green Professional 15231 Perry Lane, Morgan Hill, CA 95037 armi 1 avera&netscape. net .408-521-3740 TABLE OF CONTENTS 1. CERTIFICATION OF COMPLIANCE: RESIDENTIAL - FORM CF -1R 2. HVAC SIZING -FORM HVAC 3. MANDATORY MEASURE CHECKLIST: RESIDENTIAL - FORM MF -1 R CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 Project Title.......... Paknahal Residence Design ---------- Date..07/31/14 16:18:19 Project Address........ 22438 Cupertino Road ****** --------------------- 9.6% Cupertino, California *v8.1* I I Documentation Author... Yarmila Kennett ****** I Building Permit # I 0.0% Yarmila Kennett & Associates I I 0.20 15231 Perry Lane -------- 43.60 I Plan Check/ Date I -------- 3.77 Morgan Hill, CA 95037 (408) 621-3740 I Field Check/ Date Climate Zone........... 04 --------------------- Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-PAKNAHAL Wth-CTZ04S08 User#-MP1217 User-Yarmila Kennett & Associa Run-Paknahal Residence -------------------------------------------------------------------- = MICROPAS8 ENERGY USE SUMMARY = _---------------------------- _ = Energy Use _ (kTDV/sf-yr) ----------------------- Space Heating.......... Space Cooling.......... Ventilation Fans....... Water Heating.......... Total Standard Proposed Compliance Percent Design ---------- Design ---------- Margin ---------- Improvement ----------- 19.99 18.06 1.93 9.6% 11.33 9.69 1.64 14.5% 0.56 0.56 0.00 0.0% 11.72 11.52 0.20 1.7% -------- 43.60 -------- 39.83 -------- 3.77 -------- 8.6% _ *** Building complies with Computer Performance GENERAL INFORMATION HERS Verification.......... Not Required Conditioned Floor Area..... 3589 sf Building Type .............. Single Family Detached Construction Type ......... New Natural Gas at Site ....... Yes Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Raised Floor 1 38874 cf 0 sf 17 % of floor area 0.3 Btu/hr-sf-F 0.35 10.8 ft CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 Project Title.......... Paknahal Residence Date..07/31/14 16:18:19 I MICROPAS8 v8.1 File-PAKNAHAL Wth-CTZ04S08 User#-MP1217 User-Yarmila Kennett & Associa Run-Paknahal Residence -------------------------------------------------------------------------------- BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- -•---- ------------- ----- ------- ---------- Residence 3589 38874 1.00 4.0 Yes Setback 2.0 Standard No Surface 1 Wall 2 Wall 3 Wall 4 Wall 5 Wall 6 Wall 7 Wall 8 Door 9 Roof Rad 10 Floor 11 FloorExt Frame Area Type (sf) Wood 351 Wood 391 Wood 554 Wood 28 Wood 550 Wood 166 Wood 189 Wood 19 Wood 3589 Wood 3439 Wood 150 U- fact - or 0.102 0.102 0.102 0.102 0.102 0.102 0.102 0.500 0.032 0.037 0.048 OPAQUE SURFACES --------------- Sheath- Solar Appendix Cavity ing Act Gains JA4 R-val R-val Azm Tilt Reference 13 0 0 90 Yes 13 0 90 90 Yes 13 0 180 90 Yes 13 0 135 90 Yes 13 0 270 90 Yes 13 0 0 90 No 13 0 90 90 No 0 0 0 90 No 30 0 n/a 0 Yes 19 0 n/a 0 No 19 0 n/a 0 No 4.3.1 A3 4.3.1 A3 4.3.1 A3 4.3.1 A3 4.3.1 A3 4.3.1 A3 4.3.1 A3 4.5.1 A4 4.2.1 A8 4.4.1 A4 4.4.2 A4 Location/ Comments Typical Typical Typical Typical Typical To Garage To Garage To Garage Typical Typical 0/Basement FENESTRATION SURFACES ---------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC; Azm Tilt Type Location/Comments ------------------ ----- ----- ------ --- ------------ ------------------------ 1 Wind Front (N) 78.0 0.300 0.350 0 90 Standard Vinyl/Wood Operable Low 2 Door Front (N) 60.0 0.300 0.350 0 90 Standard Vinyl/Wood Patio Door Lo 3 Wind Left (E) 51.0 0.300 0.350 90 90 Standard Vinyl/Wood Operable Low 4 Wind Back (S) 155.5 0.300 0.350 180 90 Standard Vinyl/Wood Operable Low 5 Wind Left (SE) 32.5 0.300 0.350 135 90 Standard Vinyl/Wood Operable Low 6 Door Back (S) 72.0 0..300 0.350 180 90 Standard Vinyl/Wood Patio Door Lo 7 Wind Right (W) 40.8 0.300 0.350 270 90 Standard Vinyl/Wood Operable Low 8 Door Right (W) 120.0 0.300 0.350 270 90 Standard Vinyl/Wood Patio Door Lo CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 3 Project Title.......... Paknahal Residence Date..07/31/14 16:18:19 MICROPAS8 v8.1 File-PAKNAHAL Wth-CTZ04S08 User#-MP1217 User-Yarmila Kennett & Associa Run-Paknahal Residence ------------------------------------------------------------------------------- HVAC SYSTEMS ------------ Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or CID Airflow Draw Capacity ---------------- ----------- ----- ------------- -------- -------- -------- Furnace 0.900 AFUE n/a n/a n/a n/a n/a ACSplit 13.00 SEER No No No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) ------------------------•----------------------------- Furnace 55157 n/a n/a n/a ACSplit n/a 28124 32230 n/a Sizing Location............ CUPERTINO Winter Outside Design...... 28 F Winter Inside Design....... 70 F Summer Outside Design...... 86 F Summer Inside Design....... 75 F Summer Range ............... 30 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location R• -value Leakage Area Ducts Furnace ----------- Attic -•------------------------- R-6 No No --------- No ACSplit Attic R-6 No No No FAN SYSTEMS ------------ Flow Power System Type ----------------- (cfm) (W/cfm) ---------------- Standard 65.89 .25 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 ------------ Project Title.......... Paknahal Residence Date..07/31/14 16:18:19 I MICROPAS8 v8.1 File-PAKNAHAL Wth-CTZ04S08 I User#-MP1217 User-Yarmila Kennett & Associa Run-Paknahal Residence -------------------------------------------------------------------------•------ Heater Tank Type Type ---------------- -------- 1 Instantaneous Gas WATER HEATING SYSTEMS --------------------- Number in Distribution Type System ------------------- ------ Standard 1 Tank External Energy Size Insulation Factor (gal) R -value -------- ------ ---------- .65 n/a R-n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. This building incorporates a non-standard Water Heating System. REMARKS New Fenestration to be dual -pane, low -e typical. See Calculations for max. U -value & SHGC, CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 Project Title.......... Paknahal Residence Date..07/31/14 16:18:19 I MICROPAS8 v8.1 File-•PAKNAHAL Wth-CTZ04S08 I User#-MP1217 User-Yarmila Kennett & Associa Run-Paknahal Residence ---------------------------------------•---------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. s certificate has been signed by the individual with overall desi res onsibility. SIGN or OWNER DOCUMENTATION AUTHOR Name.. t Zazueta Name.... Yarmila Kennett Company. DZ Design Associates, Inc Company. Yarmila Kennett & Associates Address. 17705 Hale Avenue, #H4 Address. 15231 Perry Lane Morgan Hi 1, CA 95037 Morgan Hill, CA 95037 Phone... 408�y� 05 / Phone... (408) 621-3740 License. �j'A -. /„"�4 = (date) ENFORCEMENT AGENCY Name.... _ Title... _ Agency.. Phone... - Signed.. _ (date) Signed.. /, �,, ,I— 7`c�����%y 6-C (date) ABOVE CODE REPORT: RESIDENTIAL COMPUTER METHOD ACR Page 1 Project Title.......... Paknahal Residence Date..07/31/14 16.18.19 I MICROPAS8 v8.1 File-PAKNAHAL Wth-CTZ04S08 I User#-MP1217 User-Yarmila Kennett & Associa Run-Paknahal Residence ------------------------------------------------------------------------------- End Use Space Heating... Space Cooling... Ventilation Fans Water Heating... Total End Use Space Heating... Space Cooling... Ventilation Fans Water Heating... Total MICROPAS8 ENERGY USE SUMMARY ---------------------------- --------kTDV/ft2-yr-------- Stand. Prop. Percent Design Design Margin Improve 19.99 18.06 1.93 9.6% 11.33 9.69 1.64 14.5% 0.56 0.56 0.00 0.0% 11.72 11.52 0.20 1.7% 43.60 39.83 3.77 8.6% Therms Stand. Prop. Percent Design ------ Design ------ Margin -------- Improve ------ 417 373 45 10.8% 0 0 0 0.0% 0 0 0 0.0% 284 279 5 1.8% 701 651 50 7.1% CPUC kW Stand. Prop. Percent Design Design Margin Improve ------------- ------ 0.00 0.00 0.00 0.0% 4.30 3.84 0.46 10.7% 0.00 0.00 0.00 0.0% 0.00 0.00 0.00 0.0% 4.30 3.84 0.46 10.7% -------- kWh -------- Stand. Prop. Percent Design Design Margin Improve ------ ------------- ------ 519 536 -18 -3.4% 1364 1192 172 12.6% 144 144 0 0.0% 0 0 0 0.0% 2026 1872 154 7.6% Measures Site MF -IR NOTE: Low-rise residential hwldmgs subject to the Stantiiards mast comply with all qpplicable mandatory measures listed regardess of the compliance approach used More stringent energy measures listed on the CerWwate of Cong.*wlee (CF -11L CF -IR -ADD, or CF -IR ALTForm) shall supersede the items marked with an asterisk (•) below. This Mandatory Measures Summary shall be incorporated into the permit documents and the qpplicable features shall be considered by all parties as minimum component performance specificadons whether they are shown elsewhere m the documents or in this summmy. Submit all qpplicable sections ofthe MF -IR Form with plans, _ DESCRIPTION ~ Building Envelope Measures: -- 11 a 1: Doors and windows between conditioned and uncond'itionr�t are m� to limit air §116(a)4: Fenestration products (except field -fabricated windovas) have a label listing the oer ifred U-Footor, =ffiYed Solar Hees Cain Coefficient (SHGQ, and infiltration that meets the requirements of §�t0.111(a). § 117: Exterior doors and windows are • all . kiwis sod. Penetrations are caulked and sealed §118(a): Tnsuiahm or voslatled meets Standards for im-o atin;g Matariat lnd=ft type and include on CF-WForm. § 119(1): The thoracal ami ttance and solar mflactanee values of the coca] roofing material meets the miuirements of $i 18(i) whmi the installation &f - a Cool Roof is specified on the CF -IR Form _ *§l :Minimum R-19 insulation in wood -frame eei!!ngor eru�'w.ahatt U -factor. 110 (b): Doose fill insulation shall conform with mfr's instatted design labeled R Value. *§150(c): M'mimum R 13 insulation in wood -frame wall ar equivalent U -factor. *§1 d): Minimum R-13 insulation in raised wood -frame f nor or equivalead U -factor §25 : Air reiar is toasted, labeled, and installed ace _a !Nr to ASTM E1677-"(2000) when specified on the CF -1R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 1.6. §1500: Wow absorption rate for slab edge insolation material adopt: without facings is no greater, than 034* waterr than 20 h and shall be farm .tical damage and W light det>erioratioat. � P rate is ret Fireplaces, Decorative Gas Appliances and Gas Log Memirtes: §150(e)IA: Masonry or f6ctory4ndh fireplaces have a closable watEd or glass door covering the entire opening of%e firebox. § 150(e)1B: Masonry or factory -built fireplaces have a combustion outside air imake, which is at least six square inches in area and is equipped with a with a and ti iitdng and or a combustioarak control device. §l50(e)2: Continuous burning pilot lights and the use of indoor rdr for 4cooling a firebox jadm% wboo that indoor air is vented tO the outside of the Wilding, are pmhMe& Space Conditioning, Wager floating and Plumbing S tem M_feamres: 110- 113: HVAC water heaters, showerheads, lancets anal all other regulated appliances are notified W the PPOW Commission. §113(c)5: Water heating rocirculation loops serving multiple dwrilhing imits and High -Rise residential occupancies meet the air release valve, backflowirevenUm pump isolation valve, and rechrsxriatiort kto connection of ll c 5. §115: Continuously burning pilot lights are prohe'bited for natural gaer fin typo central fi roace% household cooking 4plianow (appliances with an electrical supply voltax connexion with pilot lights that imnsunw less #=150 BUYbr aro op"I and pool and sm heaters. §150(h): and/or cootHng loads are calculated in accordance vitt ASERA14 SMACNA or ACCA. 150(1: Heating systems are eqqipped. with thermostats that meet the setback requirements of stiction l l2(c). 6150(1)1A: Storage gas water heaters rated with an FneW Factor none greater than the federal minimal s�are ext�y wrtWed vin& insulation baying an installed thermal resistance: of R-12 or greater. §150()1B: Unfired storage tanks, such as storage tanks or backti p tanks for solar water -heating system, or othex indirect hotwftw tanks have R-12 external insulation or R 16 internal insulation what the internal insulattion R valw is indicated on the exterior of the tank. §1506)2: First 5 feet of hot and cold water pipes closest to wator hwwr tank, non -recirculating systems, and entim length of recircadating sections of hot water pipes ane insulated per Standards Table 1!", §1 S0(1(j)2: Cooling system piping (mwchilled water, or brine linesland piping kmilated between lxalimg source and indirect hot water tank shall be insulated to Table 150-B and 150-A. _ §150(D2: Pipe insulation: for steam hydmnic hooting systems or bot wafer systems >15 psi, meets tree retguremenb of Standards Table 123-A. §150Q)3A: Instilation.is protected from damage, including that due to sunlight; moisture, equipment mainteoaooe, and wind. §150(1')3A. Insulation for chilled wafer piping and refrigerant suction lines includes a vapor retardant or is endowed entirely m eonditlogod space. 2008 Restderttial Compliance Forms August 2009 Mandatory Measures Summa _ MT -1R Residential Site Add. as.(Pat of Enforcement Agency: p ate: 1 X150()4. Solar water -heating systems and/or collectors are cerlifed by the Solar Raibm and Certification Cntmw�inn -- � �r Ducts and Fans Measurer. §150(m)l: All air -distribution system ducts and plenums installed we sealed and inmlateci to meet the requirements of CMC Suctions 601,662—, 603, 604, 605 and Standard 6-5; supply -air and retun4r ducts and plemmns are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall to .sealed with mastic, tape or other duct -closure System thag meets the applicable requirements of UL 181, UL ISM or UL 18113 or aerosol sealant that meats the requirements of UL 723. if mastic or tape is used to seal opennigs greater dm 1/4 inA the combination ofnmainc and either mesh or tape shall be used §150(m)l: Building cavities, support platforms for air handlers, and p8mums defined or oohed with materials otter than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support pladbnw may coda ducts. Duds installed in cavities and support plWfornis shall} wt be compressed to cause reductions in the moss-sectiwtsl m+ea of the ducts. §150(m)2D: Joints and seams of flux systnns and their compcm;ents; shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bards. _ §150(m)7: Exhaust fan systems have back draft or autnma tic dammers.. 1 m)$: Crravi conditioned spue heave: either automatic or readily accessi§*pwanually operaterl § 150(m)9: Insulation shall be protected from damage, including thin: due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted wits► a costing that is water retardant and provides shielding from solar radiation that can cause on of the material. § 15 m 10: Fleta'bie ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSUASHRAE Standard 62.2-2007 Venfileflon and A le Indoor Air oaalttab Qua}ity in Low -Rise Residential Buildings. Window operation is not a permissible method ofproviding the Whole Budding Ventilation required in Section 4 ofthat Standard. Pool and Spa Beating ftstenis and Equipment Menswres: 1114(a): Any pool or spa heating system shall be certified to have: 111 thermal of iciemcy that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater, a permanent weeflun goof plate or card with operating instructions; s; and shalt not use electric resistance beating ora pflat light §114(b)l: Any pool or spa heating equipment shell be installed with st least 36" ofpipe between filter and ie_ , or dedicated suction and return lines,or built-up connections for future solarbeatin 11 )2: Outdoor p22ls or spas than have a heat pump or Vs hem shall }rave a cover. §1 14(b)3.- Pools shall have directional inlets that adequately mit rte pool water, and a time switch that will allow all pumps to be set or programmed to ruin 92!y during off- electric demand j!niods. _§150(p),Residential pool system or equipment meet the EM siziict�, flow rate, filters, and valve ents of 15 ReAdeathdMeasures: §150(k)l: High efficacy luminaires or LED Light Engine with Intgxal Heat Sink has an efficacy that is no lower them the efiiewies contained in Table 150-C and is not a low efficacy luminaire as ocified by §150(k)2. §I 3: The wattap ofpcimanently installed luminaires shall be detumined as speciSed by 9130(4). 1 N(k)4. Ballasts for fluorescentlamps rated 13 Watts or or shall be electronic and shall have an output frequency no km than 20 kHz, §150(k)5- Pexmaneattly installed night lights and night lights integral to a peraw nemdy inshiiled huuimtire or exhadest fan shall attain only high efficacy lamps meeting tits minimum efficacies conitdneei in Table 150-C and shall not contain a line -voltage socket or line -voltage lamp holder; OR shall be rated to consume no more than faro watts of power as determined by §130(4), mrd shall not contain a medium screw -base socket _ §15900: Li integrW to exhaust fans, in rooms other than kitcherm, shell meet the kop#mble requirements of §150(k)7: All switching devices and controls shall meet the tirennems of 1150(k)7. §150(k)S: A minimum of 50 percent of the trial rated wattage of pelmaanently installed lighting in kitchens shall be high esfflcacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 fl or 100 walls for dwelling units larger• than 2,500 fe may be exempt from the 50% high efficacy requitement when: all love t0cacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -some programmable control system; and all Permanently installed luminaries in garages laundry rooms, closets greaser ihim 70 square feet, and utility rooms are high efficacy and cxmtmlled by a manual -on oompant seutsor. §150(k)9. Permanently installed lighting that is internal to cabinets saladl use no more than 20 watts of power per linear foot of illuninsted cabinet. §150(k)10: Permanondy installed luminaires in bathrooms, attached a r d detached garages, laundry rooms, closer and utility rooms shall be high efficacy, zuuef xesmenuat c.ompuannce ro►ms August 2009 Mandatory Measures Summa MF -1R Residential ...._ (Page 3 of 3 Site Address: Enforcement Agency: Date; EXCEMON 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occypant sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with § 150(k) 11. §150(k)12: Luminaires recessed into insulated ceilings shall be lisled': for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including fighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having air override or bypass switch that disables the astronomical time clock; OR an energy management control system (EM(CS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor Iuminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or imwnd swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be .high efficacy luminaires. _ §150(k)14: Internally illuminated address signs shall comply with section 148; OR not contain a screw -base socket; and comume no more than five watts of power as determined according to §130 §150(k)15: Lighting for parking lots and carports with a total at for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking ganges for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146 §150(k)16: Permanently installed lighting in the enclosed, non-dwelliag spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicable requirements of §119. 2008 Residential Compliance Forrrrs August 2009 CUPERTIINO PURPOSE: CALGREEN RESIDENTIAL CHECKLIST - MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 or The 2013 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings, dormitories, condominiums, shelters, congregate residences, employee housing, factory -built housing and other types of swellings with sleeping accommodations and new accessory buildings associated with such uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Project Project Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the California Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. MANDATORY FEATURE OR MEASURE Planning and Design - Site Development Column 2 Column 3 Project Verification muirements 4.106.2 Storm water drainage and retention during construction. A plan is P UI- developed and implemented to manage storm water drainage during QX construction. A / —7-(;z ,;2 rfl 4.106.3 Grading and paving. The site shall be planned and developed to OI keep surface water away from buildings. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. T Page 1 of 5 CalGreen_2014.doc revised 01115114 A4.2 General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. A4.3 WATERAND CONSERVATION Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: ❑ 4.303.1.3.2 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank -type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specifications for Tank -type Toilets. ❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. ❑ 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum. flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ❑ 4.303.1.3.2 Multiple Showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. ❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. ❑ 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1401.1 of the California Plumbing Code. Page 2 of 5 CalGreen_2014.doc revised 01/15/14 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the time of final inspection shall be weather -based. ❑ 4.304.1.1 Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. ❑ 4.304.1.2 Weather -based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controller(s). Soil moisture -based controllers are not required to have rain sensor input. A4.4 MATERIAL Enhanced Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, a construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual. At the time of final inspection, an operation and maintenance manual shall be provided to the building occupant or owner. A4.5 ENVIRONMENTAL Fireplaces 4.503.1 General. Install only a direct -vent sealed -combustion gas or sealed wood -burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical equipment during construction. Duct openings and other related air ❑X distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be El compliant with VOC limits. 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings shall be compliant with product weighted MIR Limits for ROC and other toxic ❑X compounds. Page 3 of 5 CalGreen_2014.doc revised 01115,114 4.504.2.4 Verification. Documentation shall be provided to verify that compliant VOC limit finish materials have been used. 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with VOC limits. 4.504.4 Resilient flooring systems. Eighty (80) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools (CHPS) Low -emitting ❑X Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall ❑X comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete slab foundation. Required vapor retarders and capillary breaks are also required to comply with CalGreen Section 4.505.2.1. 4.505.3 Moisture content of building materials. Moisture content of building materials used in wall and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the building are provided in every bathroom. Environmental Comfort 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS Qualifications 702.1 Installer training. HVAC system installers are trained and certified in the proper installation of HVAC systems. 702.2 Special inspection. The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the QX discipline they inspect and verify. Verifications 703.1 Documentation. Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen 2014.doc revised 005114 Project Name: Project Address: Project Description �iT W-ciN74-M-ireiki/TddII N :291*i4W±1-TA drel 0� SECTION 1 — DESIGN VERIFICATION Complete all lines of Section 1 — "Design Verification" and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the pro'e cordance with the re ments set forth in the 2013 California Green Building Standards Code as -aod pted by the City of Cupertino. Owner's Signature A I Date Owner's Name n P—wossionars Signature Date Design Professional's Name (Please Sign ure of License Professional responsible for CalGreen compliance Date 1c &7WAdM y0,f 42/-97y6r Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance eli-# Z0 0 p- 2 L1 SECTION 2 — IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 5 of 5 CalGreen 2014.doc revised 01/15/14