Loading...
B-2017-0562CITY OF CUPERTINO BUILDING. PERMIT BUILDING ADDRESS: 10385 RIVERCREST CT CUPERTINO, CA 95014-1027 (326 37 005) OWNER'S NAME: PILLAIPAKKAMNATT DILIP AND RAGHUNATH PREETI OWNER'S PHONE: 408-242-7636 LICENSED CONTRACTOR'S DECLARATION License Class a Lie. #1010093 Contractor AT P 168 CONSTRUCTION Date 01/31/2018 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. hhave and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,. the applicant understands and will comply with all non -point source rebAtions p&r the Cupertino Municipal Code, Section 9.18. Date 04/11/2017 CONTRACTOR: PERMIT NO: B-2017-0562 ATP 168 CONSTRUCTION MILPITAS, CA 95035 DATE ISSUED: 04/11/2017 PHONE NO: (408) 726-2766 BUILDING PERMIT INFO: X BLDG —ELECT —PLUMB MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: REMODEL KITCHEN (200 S.F.), LIKE FOR LIKE Sq. Ft Floor Area: I Valuation: $2000.00 APN Number: Occupancy Type: 326 37 005 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS Tom^ D INSPECTION. Issued by: ME i Date: 04/11/2017 ' I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature of Applicant: Date: 04/11/2017 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Se iqns 25505, 25533, and 25534. Owner or authorized agennE:r,` C Date: 04/11/2017 U' CONSTRUCTION LE INGAN Y I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Signature Date 04/11/2017 Professional CUPERTINO CONSTRUCTION PERMIT APPLICATION. COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(@cupertino.org9� % A l B SGZ ❑ NEW CONSTRUCTION 1-I ADDITION. F-1 AT.TF.RATTCIN/TT FI RFVTSTC)M/TIRFFRRFTI IIATf TATAT DDWXTIu PROJECT ADDRESS l _ (� tl APN # 326 _ 3-, —60 e PHONE _MAH, OWNERNAME�^� E ? 1 VM \ C 1 t on STREET ADDRESS '' 11 /� g�1 }[�'y ZIP / B �. \ V t C. \ ' �t � 1 V � 1I � 1 � L\ G FAX CONTACT NAME t C'1 (A ` �' � /11 P U " � L 1 r ,- EMAIL STRI RE$S-C_' +� CIT T T > ZIP } G, � 115 FAX , �\\ ' ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT El ENGINEER ❑ DEVELOPER ❑ TENANT CONT I CT RN �LICTSdV� � 1 LICENSE TY BUS. LIC # 2 [[ G� S 7 / CO ` a 1 SA -6 r E-MAIL7 A AIi 1 FAX STEa, ZIP �. C �i\�y �6\ vim] �I@�(� �% `� 1 � 4 T V ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK �U CJ EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES USE TYPE 1 OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHENOTHER - REMODEL AREA REMODEL AREA �REMODEL AREA PORCH AREA DECKAREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH # DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY EJ YES BEING ADDED? ❑ NO ADDITION? ❑ NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN REC TAL VALUATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO _ By my signature below, I certify to each of the following: I am the property owner or authorized age act on th perty owner's behalf. I have read this application and the information I have pr 'ded is correct. I have read the Description of Work and verify it is urate. I agree to comply with all applicable local ordinances and state laws relaTm`Im buil ' g con n. I auth�' - mpresentatives of Cupertino to enter the above -'identified property for inspection purposes. Signature of ApplicantlAgent: Date: f— � SUPPLEMENTAL INFO ATION REQUIRED PLAN CHECK` TYPE. _ ROUTING silr El oVER-THE-COUNTER ❑ BUILDING PLAN REVIEW _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ElSTANDARD, ❑ PUBLIC WORKS To—nn if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ ❑ SANITARY submittal of Building Permit application. NIAJOR SEWER DISTRICT ❑ ENVIRONMENTAL HEALTH BldgApp_201 Ldoe revised 06/21/11 Assessor's Parcel Number: -1 1 Name of Owner: Contact Person: �C Project Address: ,---i-Cas. ,-✓ V j �," (' [^ C-Ld Scope of Work: t 1 C Ih G: h Applicable Code: 2015 California Residential Code (CRC) T 2015 California Plumbing Code (CPC) 2015 California Mechanical Code (CMC) 20115 Califrmla Electrical Code (CEC) 2015 California Energy Code (CEnerC) 2016 California Green Building Standards Code (GRN) PLUMBING: • Dishwashers shall be connected with an approved drainage air gap devices located above the flood level rim of the sink [CPC 607.31. • Newly installed kitchen faucets shall not exceed 1.8 gallens per minute ,GRN 4.303.1.4.41. • All piping 'X inch or more in diameter and all hot water pipes from the heating source to the kitchen fixtures must be Insulated with min. 1 -inch thick insulation [CEnerC 1501 Existing inaccessible piping does not recuire Insulation. MECHANICAL: • A mechanical permit is required to replace a kitchen exhaust hood that includes an outside air vent. The vent must terminate on the holding exterior A least 3 ft. from other openings into the building [CMC502.2,1]. Flexible (corrugated) ducting is not allowed for exhaust hoods [CMC SC4.3]. - I COPI 00:1tle DEV���P N�NGUPERRN 041 G�MM�ND Gpt�tS1 Oveo �evok3k\he eU\G PPQR \3 W\ to make aaY s and speciftsauwns2me of <o dev\ate ZY Is ccc:;\tucpon \t is Un Se of P�aP �t\dlo9 �t col NO adon he d s S\AP N job Site es CT a;le orOva\ iloec)m c 3"ocl the vi NDk%Or\ oYlae9om yndh� k \an e aS Stake�av . tre' eta ^GL 9' �a1 fdt, to h,\dko P- W"AS EXISTING KITCHEN FLOOR PLAN ELECTR'CAL: • All installed lighting shall be high efficacy. [CE—C 151 • Under -cabinet lighting must be switched separately from other lighting.[CErerC 150.0(k)2L] • A minimum of two 20 -amp small appliance branch circuits are required to serve countertop and wall receptacles in the kitchen, pantry and dining room [CEC 210.11A]. No built -In appliances are allowed on these circuits (except an electric clock or the Ignition of a gas range). • Indiv'..dual (dedicated) circuits are required for garbage disposals, microwaves, compactors, and dishwashers. [CEC210.19A1b] • AFCI (arc -fault circuit -interrupter) protection is required for all 120V 15-& 20 -amp kitchen circuits [CEC210.12A] • Receptacles shall be installed at each countertop space a 12 in. in width [CEC 210.52C1]. Receptacles shall be installed so that no point along the wall line',s more than 24 inches horizontally from an outlet in that space [CEC 210.52011. The maximum spacing between receptacles, measured on the wall-countenop line, is 48 Inches. • All receptacles serving kitchen countertop surfaces shall have GFCI protection [210.8A6]. • Countertop receptacles shall rot be installed in a face up position [CEC 406.5E]. Listed "pop-up" receptacles are allowed [CEC 210.52051. Receptacles or strip outlets can be installed on the underside of the cabinet above the countertop if within 20 inches of the countertop. • Dishwashers require GFCI protection, Including 241 dishwashers. (new in 2016 codes) • All GFCI device controls must be in readily accessible locations. Outlets behind a dishwasher are not readily accessible. G'wCI protection can be provided by using a GFCI circuit breaker. • All general purpose and countertop receptacles must be tamper-resistant. ICEC 406.12A) • Comer sinks separate the space on each side when the distance between the corner and the sink is s 18 inches. If a 18 in., the 2 f. / 4 ft. rule continues behind the sink [CEC 210.82041. • On islands and peninsulas only, receptacles are allowed on the side of the cabinet, not more than 12 inches below the countertop and with no overhanging countertop greater than 6Inches [CEC 210.52C5 exc.] • Bar -type counters are considered wall space. Wall spaces>_ 2 It require receptacles so that no portion of the wall Is more than 6 N. from a receptacle outlet, measured at the floor/wall line [CEC 210.52A1&2]. • A range hood / microwave combination can be cord -and -plug connected If the circuit Is an individual (dedicated) branch circuit. The receptacle outlet shall be a sing'.a type, not a duplex receptacle that would accept two plugs [CEC 422.1684]. • The 24-inchl48-Inch role does not apply to Island or peninsular countertops. These require only one receptacle per countertop space, regardless of length [CEC 2105202&3]. An island or peninsula is considered divided into separate countertop spaces when a sink or range is installed and does not have 12 Inches of space behind it. See the diagram on page 2. CUPER-1 IItlO luildinq Department Llrf�l APF i 1201? GREVIEWED FOR G(ZDE COIVIPI_IANC KeVlewed By --- .,..., __ - til 0— i .s 14 ==U9 KWIM0