Loading...
B-2017-0660CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0660 20790 HANFORD DR CUPERTINO, CA 95014-1824 (326 30 065) CLEAN SOLAR INC SAN JOSE, CA 95112 OWNER'S NAME: VAN BUREN JUSTIN LU AND ZHANG YU DATE ISSUED: 04/26/2017 OWNER'S PHONE: 408-830-7141 PHONE NO: (408) 217-8876 LICENSED ONTRA TOR'S DECLARATION BUILDING PERMIT INFO: License Class C -10/C-46 Lic, #910849 Contractor CLEAN SOLAR INC Date 02/28/2018 X BLDG _ELECT _PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing MECH X RESIDENTIAL COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALLATION OF ROOF MOUNTED SOLAR (14 MODULES)(5.04 I hereby affirm under penalty of perjury one of the following two declarations: kVA 1. I have and will maintain a certificate of consent to self -insure for Worker's as provided for by Section 3700 of the Labor Code, for the erformance of the work for which this permit is issued. 4permCompensation, have and will maintain Worker's Compensation Insurance, as provided for by ection 3700 of the Labor Code, for the performance of the work for which this it is issued. Sq. Ft Floor Area: Valuation: $27574.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 326 30 065 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the appI't understands and will comply with all non -point source regulationL-e-ftne Cupe�Mulode, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signature Date Issued by: Phuong Devries Date: 04/26/2017 OWNE -BLIWDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is 1. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code), Date: I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued, maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(x) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which a ardous air contaminants as defined by the Bay Area Air Quality Management Di 'ct I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cuper 'no Municipal Code, ter 9.1 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Se ns 25505, 25533, a 2 34. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner r authorized agent:~ APPLICANT CERTIFICATION Date: Date /7 I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws CONS �CTJ,r� I hereby affirm that there isa corl9truction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permi s issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION 1 understand my plans shall be used as public records. Code, Section 9.18. Licensed Signature Date Professional rC�U� PERTINO J�[J NEW CONSTRUCTION CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 9. 11'7 -0�(D (408) 777-3228 • FAX (408) 777-3333 • building(a)-cupertino.org �/ ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT # PROJECTADDRESS07 -7 al� n APN # O - OWNER NAME la _ J (� (�.,(•/p P��' /O 71 Ef ®d ! o� 0. `' %�I STREET AD{yDyRE ��� CHIT-aY, STATE, ZIP AXE CONTACT NAME ° a [ s pa��n'� � P f -6�- (0//W-/�� E-MAIL a � q j //7 T C✓ STREET ADDREs� ] JQ ` $ /'vr� ®„ ®� Cy" s�qq//❑ L/OWNER4AGGEENT /CONTRACTOR CITY, STATE, �"j �/e f FFAX- ❑ OWNER ❑ OWNER -BUILDER ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME d LICE f% (� `r / LIC , SF�TPE C 41Z �(� BUS. LIC # { 2 g COMPANY NAME.s,� P STREET ADDRESS � / '% CITY; S yHTL�%LIPL// - L/fie ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMP AME E-MAIL FAX T ET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK `0 e' KuJ" c, EXISTING USE PROPOSE E COTATR. TYPE FIV/l # STORIES USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG AREA NEW FLOOR AREA DEMO AREA TOTAL NET AREA n( y�� �/ / ���(((AAA _ BATHROOM REMODELAREA KITCHEN REMODELAREA OTHER _ REMODELAREA _ PORCH AREA DECK AREA TOTAL DECKIPORCH AREA GARAGE AREA: DETACH ATTACH # DWELLING UNITS: IS A SECOND UNIT []YES BEINGADDED? ❑NO SECOND STORY ❑YES ADDITION? []NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER IS THE BLDG AN ❑ YES EICHLER HOME? O � RECEIVED BY: - - TOTAL VALUATION: / �Y(�9 57 By my signature below-, I certify to each of the oll Ing: I& the property er or uthor'- d agent to act on the property owner's behalf. I hav ead thlis application and the infonnation I have provi d is orrect. I have read the cription of Wo and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buil ' nstruction. I au presentatives o upertino to enter the above-ide 'fled prope for inspectionvose . Signature of Applicant/Agent: Date: SUPPLEMEN ORMATION REQUIRED PLAN CHECK TYPE - ROUTING SLIP ❑ OVER-THE-COUNTER ❑ BUHAINGPLANREVIEW _ New SFD or Multifamil ellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to El MAJOR El SANITARY SEWER DISTRICT submittal of Building Permit application. - I ❑ ENVIRONMENTAL HEALTH - B1dgApp 2011.doc revised 06/21/11 JPH G-1 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com AERIAL MAP PARCEL MAP VICINITY MAP NTS NTS NTS INSTALLATION OF (14) SUNPOWER SPR-X22-360-C-AC AC MODULES STC RATING: 5.04 KW DC CEC RATING: 4.49 KW AC OCCUPANCY TYPE: R-3 CONSTRUCTION TYPE: V-B AHJ: CITY OF CUPERTINO APN: 326-30-065 PROJECT VALUATION: $27,574.00 G-1 SCOPE OF WORK; SHEET INDEX; VICINITY MAP G-2 NOTES; PROPERTY PLAN G-3 ROOF PLAN; EQUIPMENT LOCATIONS S-1 ROOF FRAMING PLAN; ELEVATIONS; ATTACHMENT DETAILS E-1 ELECTRICAL LINE DIAGRAM E-2 ELECTRICAL CALCULATIONS F-1 SIGNAGE Z-1+ SPECIFICATIONS SCOPE OF WORK SHEET INDEX Van Buren, Elle 5.04 kW DC SOLAR PHOTOVOLTAIC SYSTEM 20790 Hanford Dr., Cupertino, CA 95014 SEAN HATCH 04/26/17 JPH G-2 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 SCALE: 1/16" = 1'-0" LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com BACK OF RESIDENCE FRONT OF RESIDENCE PROPERTY PLAN PROPERTY LINE EXISTING RESIDENCE NOTES ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: · 2016 CBC / 2015 IBC · 2016 CRC / 2015 IRC · 2016 CEC / 2014 NEC · 2016 CMC / 2015 UMC · 2016 CPC / 2015 UPC · 2016 CFC / 2015 IFC · 2016 BUILDING ENERGY EFFICIENCY STANDARDS · 2016 CALIFORNIA ENERGY CODE TITLE 24 · 2016 CALIFORNIA HEALTH AND SAFETY CODE · WHERE APPLICABLE, RULES OF THE PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY · THE AUTHORITY HAVING JURISDICTION · MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS · CEC ARTICLE 690 · CFC ARTICLE 605.11 · IEEE STANDARD 929 · UL STANDARD 1741 · OSHA 29 CFR 1910.269 · THE AUTHORITY HAVING JURISDICTION 1. DC WIRING METHODS SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT (CEC 690.31(E)(1)) 2. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS (CRC R331.4.2) 3. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF INVERTERS, MODULES, PV SOURCE CIRCUITS, BATTERY CONNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL (CEC 690.4(E)) 4. RAPID SHUTDOWN REQUIREMENTS: PV SYSTEMS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION. PV SYSTEM CONDUCTORS OF MORE THAN 5 FT INSIDE A BUILDING, OR MORE THAN 10 FT FROM A PV ARRAY, SHALL BE LIMITED TO NOT MORE THAN 30 VOLTS AND 240 VA WITHIN 10 SECONDS OF RAPID SHUTDOWN INITIATION, IN ACCORDANCE WITH CEC 690.12 GOVERNING CODES HANFORD DR. DRIVEWAY 51'-5" 135'-5" 125'-5" 75'-5" 22'-1" 56'-3" 5'-2" SEAN HATCH 04/26/17 MP AC LC JB JB JB JPH G-3 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com MP AC LC SERVICE POINT & UTILITY METERING AC LOAD CENTER CONDUIT RUN FIRE ACCESS POINT FOR ACCESS LADDER PER CFC 605.11.3.2.1 (14) (N) SOLAR MODULES PITCH: 18° AZIMUTH (ARRAY A): 180° AZIMUTH (ARRAYS B, C): 270° TOTAL AREA OF ARRAY: 246 FT² ROOF PLAN SCALE: 3/32" = 1'-0" EQUIPMENT LEGEND JB JUNCTION BOX (E) MAIN SERVICE PANEL + (E) #4 UFER (N) AC LOAD CENTER (INSIDE GARAGE) (N) WIRING TO BE INSTALLED IN (E) ATTIC CONDUIT LICENSE HOLDER'S SIGNATURE ROOF VENTS, OBSTRUCTIONS EXISTING RESIDENCE CONDUIT TO BE RUN IN ATTIC; WIRING METHODS SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE DIRECTLY BELOW THE ROOF SURFACE COVERED BY PV MODULES. CIRCUITS SHALL BE RUN PERPENDICULAR TO THE ROOF PENETRATION POINT TO SUPPORTS A MINIMUM OF 10" BELOW THE ROOF DECKING PER CEC 690.31(E)(1); DC CONDUIT TO BE LABELED AT MAX 10' INTERVALS CONDUIT RUNS ARE APPROXIMATE AND ARE TO BE DETERMINED IN THE FIELD BY THE INSTALLERS (E) #4 WATER PIPE BOND 2ND STORY COMPOSITION SHINGLE ROOF ARRAY A ARRAY B ARRAY C 36" 18" 6" SEAN HATCH 04/26/17 (1) 5/16" x 4-3/4" SS LAG BOLT MIN. 2-1/2" EMBEDMENT FLASHFOOT-2 ALUMINUM FLASHING WITH INTEGRATED RUBBER BUSHING CAPFOOT NEOPRENE BONDED SEALING WASHER GROUNDING MODULE CLAMP IRONRIDGE XR10 RAIL JPH S-1 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 IRONRIDGE XR10 RAIL LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com FOOTINGS @ MAX. 72" OC SCALE: 1/16" = 1'-0" NTS NTS ELEVATION DETAIL ATTACHMENT DETAIL PARTIAL FRAMING PLAN WEIGHT CALCULATIONS COMPOSITION SHINGLE 24" EAVE OVERHANG TRUSSED RAFTERS 2" x 6" @ 24" OC EXTERIOR WALLS 3" - 6" TRUSSED RAFTERS 2" x 6" @ 24" OC 13'-7" 10'-6" 17'-10" 56'-10" 16'-0" SEAN HATCH 04/26/17 (N) JBOX NEMA 3R G [A] Wires in free air * (2) #12 AWG Wire & ** (1) #12 AWG EGC in SunPower Type TC-ER AC Cable [B] 1/2" EMT CONDUIT * (4) #10 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC BRANCH CIRCUIT 1: (10) SUNPOWER SPR-X22-360-C-AC MODULES BRANCH CIRCUIT 2: (4) SUNPOWER SPR-X22-360-C-AC MODULES G (N) 125A 240V AC LOAD CENTER SQUARE D HOM816L125RB [C] 3/4" EMT CONDUIT (3) #8 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC (N) PV OCPD 2P 20A (N) PV OCPD 2P 20A (N) OCPD 2P 20A (N) MONITORING SYSTEM SUNPOWER ACPV SUPERVISOR 1/2" EMT CONDUIT (3) #12 AWG THWN-2 WIRE (1) #12 AWG THWN-2 EGC UTILITY SERVICE 120/240V 1ɸ (E) MAIN METER (E) SQUARE D HOMELINE 225A SERVICE PANEL (E) 200A MAIN BREAKER (E) LOADS G (N) OCPD 2P 40A (E) #4 UFER + (E) #4 WATER PIPE BOND JPH E-1 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com ELECTRICAL LINE DIAGRAM NOTES: · MODULES ARE BONDED TO RAIL USING UL 2703 RATED BONDING SYSTEM - INTEGRATED BONDING MID-CLAMPS + DIRECT-BURIAL LAY-IN-LUGS; SEE ATTACHED FOR SPECIFICATIONS · WHEN UTILIZING THE 120% RULE, BACKFED PV BREAKERS WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET F-1 · PV DC SYSTEM IS UNGROUNDED · BACKFED PV BREAKER WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET F-1 · WHEN PRESENT, THE GEC TO BE CONTINUOUS AS PER CEC 250.64(C) AND TO TERMINATE AT A GROUNDING ELECTRODE · FOR ALL SYSTEMS OVER 250V, CONCENTRIC AND ECCENTRIC KNOCKOUTS SHALL BE PROPERLY BONDED * EACH SUNPOWER AC MODULE INCLUDES A FACTORY-INTEGRATED MICROINVERTER (MI) THAT DOES NOT REQUIRE A NEUTRAL WIRE TO BE CONNECTED TO IT FOR OPERATION OR FOR COMPLIANCE WITH IEEE 1547. POWER PRODUCED IS CONDUCTED ON THE L1–L2 240 VAC OR 208 VAC GRID CONNECTION. UTILITY INTERACTIVE FUNCTIONS IN THE MI CIRCUITRY HAVE BEEN EVALUATED TO IEEE 1547, AND USE THE GROUND WIRE INSTEAD OF THE NEUTRAL TO DETERMINE GRID VALUES. THIS FUNCTIONALITY IS PART OF ITS UL LISTING. ** GROUND PATH IS AS FOLLOWS: ONLY AC EGC IS REQUIRED FOR AC MODULES - NO DC EGC OR GEC REQUIRED; INTEGRATED BONDING IN RACKING BONDS RACKING TO MODULE FRAMES; MODULE FRAMES HAVE INTEGRATED BONDING TO CONNECT INTO AC CABLE; NO ADDITIONAL GROUNDING WIRES REQUIRED SEAN HATCH 04/26/17 JPH E-2 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com ELECTRICAL CALCULATIONS SEAN HATCH 04/26/17 JPH F-1 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com LICENSE HOLDER'S SIGNATURE CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 20790 HANFORD DR., CUPERTINO, CA 95014 PV SOLAR ARRAY K AC LOAD CENTER (PV BREAKERS LOCATION) SIGNAGE FORMAT: ALL LETTERS SHALL BE CAPITALIZED, 3/8" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON-BOLD; REFLECTIVE, ON WEATHER- RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. TO BE PLACED JUNCTION BOXES, DISCONNECTS, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES; MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS: WARNING: PHOTOVOLTAIC POWER SOURCE CAUTION - PHOTOVOLTAIC AC DISCONNECT PV SYSTEM DC DISCONNECT RATED MAX POWER-POINT CURRENT - N/A RATED POWER-POINT VOLTAGE - N/A MAXIMUM SYSTEM VOLTAGE - N/A SHORT CIRCUIT CURRENT - N/A WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: 18.6 A NORMAL OPERATING AC VOLTAGE: 240 V B TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE AND SUBPANEL TIE-IN LOCATIONS: TO BE INSTALLED AT THE MAIN SERVICE PANEL, AC DISCONNECT, AND SUBPANEL TIE-IN LOCATIONS: TO BE INSTALLED NEXT TO THE PV BREAKER AT THE MAIN ELECTRICAL SERVICE AND SUBPANEL TIE-IN LOCATIONS: C A WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED TO BE INSTALLED AT THE INVERTER (GROUNDED SYSTEMS, NEAR GROUND FAULT INDICATOR): F TO BE INSTALLED AT THE DC DISCONNECT: TO BE INSTALLED AT THE AC DISCONNECT: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT THE JUNCTION BOXES, INVERTER, AND DC DISCONNECT (UNGROUNDED SYSTEMS): G D I J ELECTRIC SHOCK HAZARD NO USER SERVICEABLE PARTS INSIDE CONTACT AUTHORIZED SERVICER FOR ASSISTANCE TO BE INSTALLED AT THE JUNCTION BOXES: E WARNING - INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE TO BE INSTALLED AT THE ELECTRICAL SERVICE: A DIRECTORY PLACARD INDICATING LOCATION OF SERVICE AND PV SYSTEM DISCONNECTING MEANS IF NOT AT THE SAME LOCATION WARNING: ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT THE DC DISCONNECT: H SIGNAGE SIGNAGE LOCATIONS - AC MODULE SYSTEM PV ARRAY JUNCTION BOX PV LOAD CENTER (WHEN PRESENT) AC DISCONNECT (WHEN PRESENT) PV METER (WHEN PRESENT) MAIN SERVICE PANEL E SUBPANEL (WHEN PRESENT) A A A B C C C C D D D D I K L PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TO BE PLACED AT THE SERVICE DISCONNECT: L SERVICE POINT & UTILITY METERING SEAN HATCH 04/26/17 PHOTOVOLTAIC MODULE SPECIFICATIONS JPH Z-1.1 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com SEAN HATCH 04/26/17 JPH Z-1.2 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com AC MODULE UL LISTINGS SEAN HATCH 04/26/17 JPH Z-1.3 SHEETNUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com AC MODULE UL LISTINGS SEAN HATCH 04/26/17 MONITORING SPECIFICATIONS JPH Z-2 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com SEAN HATCH 04/26/17 FOOTING SPECIFICATIONS JPH Z-3 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com SEAN HATCH 04/26/17 JPH Z-4.1 SHEETNUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 RACKING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com SEAN HATCH 04/26/17 JPH Z-4.2 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com RACKING ENGINEERING SEAN HATCH 04/26/17 JPH Z-4.3 SHEETNUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com RACKING FIRE RATING RACKING ENGINEERING SEAN HATCH 04/26/17 JPH Z-5.1 SHEETNUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 GROUNDING & BONDING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com SEAN HATCH 04/26/17 JPH Z-5.2 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 GROUNDING & BONDING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com SEAN HATCH 04/26/17 JPH Z-6 SHEET NUMBER: DRAWN BY: DATE: REV: 4/21/17 4/21/17 PROJECT: CS PROJECT ID: 2840-MZ VAN BUREN, ELLE 20790 HANFORD DR., CUPERTINO, CA 95014 (415) 830-7141 CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www. cleansolar.com PV LOAD CENTER SPECIFICATIONS SEAN HATCH 04/26/17