13110172CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 5 INFINITE LOOP CONTRACTOR: NOVO CONSTRUCTION PERMIT NO: 13110172 OWNER'S NAME: APPLE COMPUTER INC 1460 O'BRIEN DR DATE ISSUED: 12/23/2013 OWNER'S PHONE: 4157103063 MENLO PARK, CA 94025 PHONE NO: (650)701-1500 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ APPLE TENANT IMPROVEMENT - 3RD FLOOR SOUTH y q License Class_ Lic. # / ! Z Z EAST (8200 SQ FT) 1 L Z T Contractor dyd `�..t5-rrvtn-^=• Date / T 1 hereby affirm that I am licensed under the provisions If Ch Ater 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $1200000 performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by ection 3700 of the Labor Code, for the performance of the work for which this APN Number: 31602109.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter WITHIN180-BAYS OF PERMIT ISSUANCE OR upon the above mentioned property for inspection purposes. (We) agree to save 1 AYS FROM LAST CALLED INSP TI N. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply Issued by: / Date: with all non -point source regulations per a Cup ino Municipal Code, Section 9.18. RE -ROOFS - Signature Date / 3 V All roofs shall be inspected prior to any roofing material being installed. If a roof is 171 installed without first obtaining an inspection, I agree to remove all new materials for inspection. ElOWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino mcipal Code, apter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 2 and 534 Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized age Date: /Z -/z- 3 .7 permit is issued. 1 certify that in the performance of the work for which this permit is issued, I shal I not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. w'ork's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(ftuoertino.ora (30 /2/ B ❑ NEW CONSTRUCTION ❑ ADDITION ALTERATION / Tl ❑ REVISION /DEFERRED ORIIGINAL PERMIT # PROJECT ADDRESS APN # ! n b -2- r `�J 9 N / ` OIAINER NAT14E PHONE E-MAIL bt0k2 a Ir cv oc 6-, c a STREE ADDRESS CITY, STATE, ZIP FAX /A/,C-fti17t- C�o� ��,�_� �,.�a CA CJt CONTACT NAMEPHONE t/w)NI lE. E -MOIL e70 8`I7- t 9 STREET ADDRESS g2i1EN ♦/C-- CITY, STATE, ZIPL q IC. AZ K (�Y-1 ! OZ`% FA�X "J 7031 IC70 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE Vil BUS. LIC # v'Ira rs�„�7�vJ 1b G36,t COMPANY NAME E-MAIL AX ) 1 cAvco �ws c 7�u+J (, o 7oi-t5a STREET ADDRESS 1�« r' 4c:� CITX, STATE, ZIP (_L; � r`� x%1-1 02S HONE &yL2) 10�-tSd� p`13,zt ARCHITECT/ENGINEER NAME /� NUMBER BUS. LIC # i '1 rzf"l 1 1Z,7_7CENSE COMPANY NAME E-MAIL FAX STREET ADDRESS [[ / d_ CIT' STATE, ZIP PHONE lO DESCRIPTION OF WORK NiFIL,m.2 E 7` /� ?�cclC�� <v� <,s1 t.( L1I (3 S Ar -i D •t TE o FT- t CIEs R e-L--{-J�li "a ~/ 2 t /AC-�2 vw i 131 ©c)1(O 5 EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES y7 !� 16 14 S USE TYPE OCG SQ.FT. VALUATION (5) 17CISTG AREA y>_ ,2 NEW FLOOR ARTA .Q L,Q DEMO AREA TOTAL NET AREA t3 2-f7 O , Q t� L I Zo 0, o C� BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKTORCH AREA GARAGE AREA: HDETACH ATTACH DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY ❑ YES BEING ADDED? []NO ADDITION? []NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN [] YES BY: -T - - TOTAL VALUATION: PLANNING ADPL q [:]RECEN NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO O U By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to nstructio . autho repre t e Cupertino to enter the above -identified pr perry for inspection purposes. Signature of ApplicanVAgent: f C7�/ Date: 11 Z-Cj �� TAL INFORMATION REQUIRED SUPP.Itifamily PLA -k CHECK TYPE. ROUTING SLIP New SFD or 1\ dwellings: Apply for demolition permit for ❑ 'ovER-TIrE-COUNTER BUU.61NG PLAN REVIEW existin; building(s). Demolition permit is required prior to issuance of building ' permit for new building. ❑ EXPRESS PLANNLNGPLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure STANDARD ❑ PIJSLtc RORKS To—nn if any Hazardous Materials are being used as part of this project. ❑ ` LARGE' FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to Cl MAJOR ❑ SANrrARY SE*,\'ER DISTIUCT submittal of Building Permit application. LJ ' ENVIRONTWMNTALHEALTII B1dgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO IM -7 FEE ESTIMATOR - BUILDING DIVISION iaADDRESS: 5 infinite loop DATE: 11/26/2013 REVIEWED BY: Mendez PC FEE ID APN: BP#: *VALUATION: 1$1,200,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Tenant Improvement PRIMARY Commercial Building USE: 1BTIPLNCK PENTAMATION 1B TI PERMIT TYPE: WORK a le- 3rd floor comm.t.i to include conference rooms labs and private office SCOPE OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA s.f. PC FEES PC FEE ID BP FEES BP FEE ID B (Tenant Improvements) II-B,III-B,IV,V-B 8,200 $2,529.72 1BTIPLNCK $5,722.72 1BTIINSP $0,00 PME Plan Check: $0.00 Permit Fee: $5,722.72 Suppl. Insp. Fee:Q Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 TOTALS: 8,200 $2,529.72 Conslrzrction Kn.' $5,722.72 MECH. HOURLY 0'Yes ( No PLUMB, HOURLY ©`Yes No ELEC HOURLY ( Yes 1Q No it.�rlt. or. Ile "A 7F Plan Check Fee: .fr.�.1',r�1..,_ ....................... ------------ Select a Misc Bldg/Structure or Element of a Building O��ik 1`7 Ui:'i1.,j7.P. hrs $0,00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District ete ). These fees are hased on the nreliminary information availahle and are only an estimate. Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,529.72 Select a Misc Bldg/Structure or Element of a Building Suppl. PC Fee: (j)Reg. 0 OT FO,0 hrs $0,00 PME Plan Check: $0.00 Permit Fee: $5,722.72 Suppl. Insp. Fee:Q Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Conslrzrction Kn.' :1c%nini.tittrdtil°a Fc c: G Work Without Permit? 0 Yes (F) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure Q fru. el f)ocrrlrr<�rrtc:ri«r, FcrF'.;: Strong Motion Fee: IBSEISMICo $252.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $48.00 SUBTO'T'ALS: $8,552.44 $0.00 "TUTA FEE:' $8,552.44 Revised: 10/01/2013 TESTING ENGINEERS, INC. 2811 Teagarden St. 510-835-3142 510-834-3777 fax San Leandro, CA 94577 800-660-3142 PROJECT # 58136 PROJECT: I1,05.3SE Retool 5 Infinite Loop Cupertino, CA Permit # 1311-0172; 1302-0034 DATE 2/4/14 HOURS 4 INSPECTOR M. Tellesen San Leandro • San -lose • Martinez INSPECTION REPORT Week Ending: 2/7/14 Reported to Rob of Novo Construction at the jobsite as requested. TYPE OF INSPECTION: Concrete Placement PLACE OF INSPECTION: jobsite Inspected placement operations and vibrating procedures. Performed 1 slump test (4") and cast 1 set of compression test specimens (5 each) Sample # 240068, for Quikcrete 5000 jobsite concrete mix (specified strength 2500 psi) for concrete placed at floor patch on 3rd floor. Total bags placed: 3. The preceding work was, to the best of my knowledge, in compliance with approved plans and specifications, including revisions by engineer, and Drawing SK -2, dated 11/26/13. Reviewed by: 15avid Chfppero Special Inspection Division Manager 1cc: Apple Computer Inc./C. Kealey, The CRE Group R—ECEIVED Novo Construction/M. Davis Studios Architecture/ C. Carrie FEB 2 4 2014 SW Structural, Inc./S. Wade City of Cupertino/Bldg. Inspection Dept. BY Taus report can be reproduced only in its entirety unless written pernussion hone TEI is obtained. Page 1 of 1 TESTING ENGINEERS, INC. 2811 Teagarden St. 510-835-3142 510-834-3777 fax San Leandro, CA 94577 800-660-3142 PROJECT # 58435 PROJECT: IL05.3N HWE Retool 5 Infinite Loop Cupertino, CA DATE HOURS Permit # 13110172 12/26/13 INSPECTOR M. Tellesen San Leandro • San Jose • Martinez INSPECTION REPORT Week Ending: 12/27/13 TYPE OF INSPECTION: Expansion Anchors PLACE OF INSPECTION: Jobsite Reported to Rob Morton of Novo Construction at the Jobsite as requested. Inspected predrilled holes for proper diameter and depth. Observed the cleaning of holes and witnessed the proper insertion of one hundred (100)1/z" diameter Hilti KB -TZ expansion anchors, 32/4' in length, embedded 2" for anchoring half wall braces to elevated slab between lines W and V from 11 to 13. T'he preceding work was, to the best of my knowledge, in compliance with approved plans and specifications, including revisions by engineer, dated 11/26/13. Reviewed by 15avid Chippero Special Inspection Division Manager 1cc: Novo Construction/ M. Davis Apple Computer Inc./C. Kealey, The CRE Group SW Structural, Inc./S. Wade Studios Architecture/C. Currie City of Cupertino/Bldg. Inspection Dept. This report can be reproduced only in its entirety unless written perntission from TEI is obtained. Page 1 of 1 p0ff Patricia Garcia From: Jacob White Dwhite@novoconstruction.com] Sent: Monday, December 16, 2013 9:52 AM To: Patricia Garcia Subject: Sub List - Permit #13110172 Hi Patricia, Please find the subcontractors we are using for Permit #13110172 listed below: • TrimTech, Inc. • SD Flooring • Magnum Drywall and Paint • Cupertino Electric, Inc. • Floor Seal Technology, Inc. • United Mechanical, Inc. • MGC, Inc. dba Mission Glass • Commercial Casework, Inc. • Northgate Acoustics • BT Mancini Co., Inc. • BFP Fire Protection • Surface & Shading Solutions, Inc. Thank you, WHaT EC riv- f-, i Dark, ca 04025 47.8'912 ta.701.1501 WWW.NOVOCONSTRUCTION.COM Recently Recognized as #3 Commercial Contractor in Silicon Valley