B-2017-0811CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0811 816 COTTONWOOD DR CUPERTINO, CA 950144622 (369 18 018) COMPLETE CONSTRUCTION EXPERTS INC SAN JOSE, CA 95129 OWNER'S NAME: COSTANZO JEANNETTE I TRUSTEE & ET AL DATE ISSUED: 05/22/2017 OWNER'S PHONE: 415-610-6155 PHONE NO: (408) 650-2432 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class GENERAL BUILDING CONTRACTOR Lic. #1009320 Contractor COMPLETE CONSTRUCTION EXPERTS INC Date 12/31/2017 X BLDG X ELECT _PLUMB — MECH X RESIDENTIAL — COMMERCIAL I hereby affirm, that I am licensed under the provisions of Chapter 9:(commencing — with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: KITCHEN REMODEL (135 S.F.); PANEL UPGRADE (200 AMPS); I hereby affirm under penalty of perjury one of the following two declarations: REPLACE WINDOWS (9) AND DOORS (3); REROOF; COMP 1. Lhave and will maintain a certificate of consent to self-insure'for Worker's SHINGLES (15.83 SQ); REPLACE OUTLETS/SWITCHES/LIGHT Compensation, as provided for by Section 3700 of the Labor Code, for the FIXTURES THROUGHOUT THE HOUSE ,(50) erformance of the work for which this permit is issued. REV #1 - NEW BEAM IN KITCHEN, - ISSUED 8/18/2017 I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $35000.00 permit, is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances and state laws relating,to building construction, and hereby authorize 369 18 018 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the �I City of Cupertino against liabilities, judgments, costs,.aO xpenses which PERMIT EXPIRES IF WORK:IS NOT STARTED may accrue against said City in cquence ora ng of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant us and w* omp with all non -point C C Section 9.18. LAST INSPECTION. source regulations perte ertino M >Eipipal 180 DAYS FROM CALLED gnature Date 8/18/2017 Issued by: Abby Ayende �ZZER-BIZWrR<ID)ECLARATION Date: 05/22/2017 ' I IS I ere . by affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS' All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: r. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection., sale (Sec.7044, Business & Professions Code) z. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 8/18/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER t. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALSDISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 ,of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle bazar material. Additionally, should+I use equipment or devices emit zardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Qua ' nag ent Distri Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino ci Cod ha 9. d exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sectio 55 , 2553 , a 53 Labor Code, I must forthwith comply with such provisions or this permit shall j be deemed revoked. 4100er or authorized agent: APPLICANT CERTIFICATION Date:8 8 i I certify that I have read this application and state that the above information is STRUCTION-LENDING AGENCY I hereby affirm tha there is a construction lending agency for the performance correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec: 3097, Civ C.) to enter upon the above mentioned property for inspection purposes: (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities; judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION 1 understand my plans shall be used as public records. Code, Section 9.18. Licensed Signature Date 8/18/2017 Professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE e CUPERTINO, CA 95014-3255 (408) 777-3228 • buildin @cupertino.or ; PEMIT #B - Lon- CUPERTINO I REV # 1 DEF # ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ T.I. ❑ MEP ❑ RE -ROOF ❑ SWIMMING POOL/SPA PROJECT. ADDRESS r, A\("\J(l APN# �6qj7'� j aVV h —\ O40y\\& Ip t(� MMA Y HONE -6l0 6 l� E-MAIL S E T DD SS CITY, STATE, ZIP' [ e v CONTRACTOR NAME ❑ OWNE -BUILDER COMPANY N ff LICEN E NUMBER LI SE TYPE CO ` rC Cad r�� l co 20 STREET ADDRESS STATE, ZIP OfE- PHONE BUS. LIC # \r09— 6 (Jl j,, se,401�Aocs ❑ ARCHITECT ❑ OWNER ❑ OWNER AGENT ❑ CONTRA AGENT❑ ENGINEER ❑ DEVELOPER ❑ TENANT CO� Tf CT ME I v c� 1& E-MAIL I f V� . `/�f `Se J i ` A o-r'r y� G�'� C& . ST Z, 0:5SS J CI TATE, ZIP C1. G� Il JZ S d e � `1.� 6 0 S DECRIPTON a ❑SINGLE-FAMILY/DUPLEX ❑ MULTI -FAMILY ❑ INDUSTRIAL, []COMMERCIAL USE TYPE OCC SQ.FT. VALUATION ($) EXISTING USE I EXISTING IF NEW FLOOR IF PORCH SF DECK IF DEMO IF STORIES # TOTAL NET IF REMODEL REMODEL KITCHEN REMODEL OT IR GARAGE ❑ ATTACHED BATHROOM IF IF IF IF ❑ DETACHED EXIS FIRESNG 11 YES SPRINKLERS E] NO EICHLER 0 NO YES SECOND STORY ADDITION YES ❑❑ NO DWELLING SECOND DWELLING ❑ YES ❑ ATTACHED ❑ DETACHED OTHER UNITS # UNIT ADDUON: ❑ No S F POOLS ❑ FIBERGLASS ❑ VINYL -LINED ❑GUNITE ❑ PREFABRICATED POOL - IF SPA - IF SPA ATTACHED ❑ YES ® NO TOTAL - IF Commercial or Multi -Family Buildings with Public Swimming Pools requires Department of Environmental Heath approval RECELYED BY: TOTAL VALUATION: RE -ROOF EXISTING ROOF TYPE: ❑ BUILT-UP ROOF ❑ ASPHALT SHINGLES❑ WOOD SHAKES ❑ WOOD SHINGLES ❑ TILE OTHER (SPECIFY) REMOVE /REPLACE ❑ NO IF NO PLYWOOD 3/8" PLYWOOD TYPE: PITCH: ROOF CLASS El YES I # OF LAYERS THICKNESS ❑ 5/8" OTHER ❑ OSB ❑ CDX OTHER .12 A PROPOSED ROOF TYPE: ❑BUILT-UP ROOF ❑ASPHALT SHINGLES ❑ WOOD SHAKES ❑ WOOD SHINGLES ❑ OTHER "Provide a signed copy of the Cupertino's Tear -Off Policy SF #of SQUARES By my signature below I certify to each of the following: I am the property owner o rized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I h read th Description of Work and verify itis accurate. I agree to comply with all applicable local'ordinances an ate laws ating wilding nstruction. I authorize representatives of Cupertino to enter the above -identified property for insp o urpos ac ledge uthorize all information contained on this application form to be made available for public record. - Signature of Applicant/Agent: Date: SUPPLEMENTAL INFOR ON REQ 4emolition *New SFD/Second Dwelling Units/Multifamily Dwellings: permit is required prior to issuance of a building permit for all new construction. *Commercial Buildings: Provide a completed Hazardous Materials Disclosure form if any Hazardous Materials are being used as part of this project. *Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. *HOA -Provide a letter of approval from the Home Owner's Association BldgApp 2017.doc revised 08/01117 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0811 816 COTTONWOOD DR CUPERTINO, CA 950144622 (369 18 018) COMPLETE CONSTRUCTION EXPERTS INC SAN JOSE, CA 95129 OWNER'S NAME: COSTANZO JEANNETTE I TRUSTEE & ET AL DATE ISSUED: 05/22/2017 OWNER'S PHONE: 408-386-1193 1 1 PHONE NO: (408) 650-2432 License Class @ Lic. #1009320 Contractor COMPLETE CONSTRUCTION EXPERTS INC Date 12/31/2017 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: t. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the apelicant understands and will comply with all non -point source regulaticlsr s p r the Cupertino Municipal Code, Section 9.18. ;Zignature Date73tMNITh �I ./► t 1 t t t L: s I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 5/22/2017 BUILDING PERMIT INFO: BLDG X ELECT _ PLUMB MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: KITCHEN REMODEL (135 S.F.); PANEL UPGRADE (200 AMPS); REPLACE WINDOWS (9) AND DOORS (3); REROOF; COMP SHINGLES (15.83 SQ); REPLACE OUTLETS/SWITCHES/LIGHT FIXTURES THROUGHOUT THE HOUSE (50) Sq. Ft Floor Area: I Valuation: $35000.00 APN Number: Occupancy Type: 369 18 018 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Abby Aygnde RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed withoutfust ob in g an inspection, I agree to remove all new materials for inspection. f Signature of Applicant: Date: 5/22/2017 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the C ertino Municipal Code, Chapter 9.12 and the Health & Safety Co e, ctions 25505, 25533, and 25534. Owner or authorized agent: Date: 5/22/2017 I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(cDcupertino.orq ❑ NEW CONSTRUCTION ❑ ADDITION 11 LTERATION ! TI ❑ REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS LJ APN / OWNER NAME � 1 � C'0 S � � PH E 3�6� � I� E-MAIL n 0/ �r j�� STREETADDRESS %� `1_ ✓'l w�/'� [ LJ': (I�11,, CJl CITY, STAT ZIP 1^� C O T FAX CONTACT NAME PH i E-MAIL n V� / ) _'1 STRE )DRESS n ^ fj 3S SeloS v 1 w CIT " ST. ,ZIP G do h FAX 13OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT Io CONTRACTOR-ry-TCONTRACTORAGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEvELOPER ❑ TENANT CONTRA OR 1,JAME LI NSE NUMBER TLIC2 TYPE BUS. LIC COMPANY NAME E-MAIL FAX STREET ADDRESS CITY' TATE, ZIP C PHONE 2ev� h� c„ ✓A Jic �S ARCHITECTIENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-M.AIL R X STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF w'ORK ` �^ /J �l r _ ( ) qr - NII L(�cs r S ` +w� npPJ0J EXISTING USE F— PROPOSED USE CONSTR. 2--. Y TYPE `' -81 # ST RIES It USE TYPE OCC, SQ.FT. VALUATION {$j EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODELAREA REMODELAREA r REMODELAREA PORCH AREA DECK AREA TOTAL DECK PORCH AREA GARAGE AREA. DETACH ❑ ATTACH I DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY ❑ Y"ES BEING ADDED? ONO .ADDITION? ONO PRE -APPLICATION [3YES IF YES, PROVIDE COPi" OF IS THE BLDG AN ❑ YES VE BY: TOWV.j�LUATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? E] NO& /�/� 00,0 1 By my signature below-, I certify to each of the following: I am the property owner or authorized agent to act on t4c property owner's behalf. I have reaad this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building cons Ion. author'Ze representatives of Cupertino to enter the above-ident ed property for inspection purposes. Signature of ApplicanGAgent: Date: 2/ SUPPLEMENTAL INFORMATIO REU D PLAN CHECK TYPE ROUTING SLIP ❑ OYER-THECOUNTER ❑ BUILDING PLAN REVIEW New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building ❑ r�In1 permit for new building. ExPREss t l PLANMNG PLAN PYV-MW v `lam Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH B1dgApp_2011. doc revised 0621.11 (E) 8068 SLIDER (E) 6030 SL (E) 6030 SL (E) 6030 SL (E) 6030 SL (E) 3020 SL (E) 3020 SL (E) 16070 GARAGE (E) 6040 SL (E) 4036 SL (E) 6020 FX (E)2468 (E)2668 (E)2468 (E)2068 (E)2868 (E)2668 (E)2668 (E)2668 (E)1668 (E)2868 (E)3068 (E)2068 OPEN Master Bedroom Bedroom 2 Bedroom 3 Bedroom 4 Hall Entry Kitchen Nook Garage Family Room FAU WH W D (E) SOFFIT TO BE REMOVED 100A LEGEND NEW WALLS EXISTING TO REMAIN DEMO (E) WALLS Kitchen Nook 3'-9 1 2 " 3'-5 1 2 " 3'-10" 3'-10" MICROWAVE 9'-6" 3'-1" 7'-2" 7'-4" 2'-0" 1'-0" (N) 8068 SLIDER (N) 6030 SL (N) 6030 SL (N) 6030 SL (N) 6030 SL (N) 3020 SL (N) 3020 SL (E) 16070 GARAGE (N) 6040 SL (N) 4036 SL (N) 6020 FX (E)2468 (E)2668 (E)2468 (E)2068 (E)2868 (E)2668 (E)2668 (E)2668 (E)1668 (N)2868 (N)3068 (E)2068 OPEN Master Bedroom Bedroom 2 Bedroom 3 Bedroom 4 Hall Entry Garage Family Room FAU WH W D 200A VIF (E) DOOR IS 20 MINUTE FIRE-RATED, SOLID CORE & SELF CLOSING/LATCHING GENERAL NOTES THE FOLLOWING NOTES REQUIRE MANDATORY COMPLIANCE BY THE GENERAL CONTRACTOR AND SUBCONTRACTORS WORKING ON THIS PROJECT. 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2016 CALIFORNIA BUILDING, ELECTRICAL, PLUMBING, ENERGY AND MECHANICAL CODES AND CITY OR COUNTY MUNICIPAL CODE, AND TO INDUSTRY STANDARDS. 2. WATER CLOSET SHALL HAVE A MAXIMUM OF 1.28 GALLONS PER FLUSH. 3. VENTING OF WASTE LINES SHALL BE CAST IRON OR COPPER U.O.N. 4. ALL WORK, MATERIAL AND CONSTRUCTION SHALL BE DONE IN CONFORMANCE WITH THE STANDARDS OF LOCAL SANITATION AND FLOOD CONTROL DISTRICT. CONTRACTOR SHALL HAVE A COPY AVAILABLE AT THE JOB SITE AT ALL TIMES. 5. EXISTING UTILITIES MUST NOT BE INTERRUPTED UNTIL THE UTILITY COMPANY HAS PROVIDED ALTERNATE SERVICE FACILITIES. THE CONTRACTOR SHALL COOPERATE AND COORDINATE HIS WORK WITH THE APPROPRIATE AGENCIES AND UTILITY COMPANIES. 6. APPROVAL OF THESE PLANS DOES NOT RELEASE THE DEVELOPER AND CONTRACTOR OF THE RESPONSIBILITY FOR CORRECTION OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED THEREIN, IF DURING THE COURSE OF CONSTRUCTION OF THESE IMPROVEMENTS, PUBLIC INTEREST REQUIRES A MODIFICATION OF OR A DEPARTURE FROM THE SPECIFICATIONS AND DETAILS OF THE CITY OR COUNTY OR THESE PLANS, THE CITY ENGINEER SHALL HAVE THE AUTHORITY TO REQUIRE SUCH MODIFICATION OF DEPARTURE AND TO SPECIFY THE MANNER IN WHICH THE SAME IS TO BE MADE. 7. ANY ERRORS, OMISSIONS OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNER/DEVELOPER BEFORE PROCEEDING WITH THE WORK. 8. A COMPLETE SET OF STAMPED APPROVED PLANS MUST BE ON THE JOB SITE. 9. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. 10. WRITTEN DIMENSIONS TAKE PRECEDENCE. DO NOT SCALE DRAWINGS. 1 4"=1'-0" Existing Floor Plan 1 A-1 DATE SCALE DRAWN BY DWG FILE SHEET REVISIONS BY Koi Design Services 1271 Washington Ave. #930 San Leandro, California 94577 (510) 282-0662 of PROPOSED / EXISTING FLOOR PLANS COSTANZO RESIDENCE 816 COTTONWOOD DR. CUPERTINO, CA. 95014 A-1 2 7 1 4"=1'-0" Proposed Floor Plan 2 A-1 Tempered Phuong Devries 05/23/17 WH W D +42" +42" +42" +42" +42" L WP L WP HB HB CM +42" +42" 200A UPGRADE TO (N) 200A PANEL 3 3 3 3 3 3 3 3 CM WP WP WP WP WP DISPOSAL SWITCH 4 WAY SWITCH GAS SUPPLY CABLE TV OUTLET 3 WAY SWITCH EXHAUST FAN, MIN 5 AIR CHANGES/HR TELEPHONE JACK HOSE BIB CHIME WALL REGISTER FLOOR REGISTER WITH BATTERY BACK UP GARAGE DOOR OPENER CEILING REGISTER DOOR BELL BUTTON CEILING RETURN AIR REGISTER PUSH BUTTON JUNCTION BOX LOW VOLTAGE ILLUMINATED HOUSE NUMBER SMOKE DETECTOR, 110V, INTERCONNECTED FLUORESCENT TUBE FIXTURE HB D G 4 3 DISP ELECTRICAL LEGEND DUPLEX OUTLET RECESSED CEILING HIGH EFFICIENCY HIGH EFFICIENCY LIGHT & EXHAUST FAN COMBINATION, MIN 5 AIR CHANGES/HR (12" ABOVE FLOOR, U.N.O ) OUTLET WITH WEATHERPROOF COVER GROUND FAULT INTERRUPTER OUTLET HALF SWITCHED OUTLET CEILING MOUNTED HIGH EFFICIENCY 220V. OUTLET WALL MOUNTED HIGH EFFICIENCY WP L UNDER CAB FF 12", 18", OR 20" 110V, INTERCONNECTED WITH BATTERY BACK UP CARBON MONOXIDE & SMOKE DETECTOR, CM SUN TUBE MOTION CONTROL OCCUPANCY SENSOR O.S. HIGH EFFICIENCY PENDENT CEILING FAN ELECTRICAL PANEL, MIN. SIZE 3-WIRE, 100A PANEL 1. FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENT IN THE EVENT OF IGNITION OR FLAME FAILURE. CMC AND CPC 2. GAS PIPING EXTENDING THROUGH FOUNDATION WALL SHALL BE SLEEVED AND HAVE ITS OPENING SEALED ON INSIDE AND VENTED TO OUTSIDE. CPC SEC. 1211.0 3. ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE GFI PROTECTED IN KITCHEN AREA. CEC SEC. 210.52C 4. PROVIDE MIN. TWO (2) 20-AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN AND SHALL HAVE NO OTHER OUTLETS. CEC SEC. 210.52B2 5. A DEDICATED 20-AMP CIRCUIT SHALL BE PROVIDED TO SERVE THE REQUIRED BATHROOM OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPACLES/LIGHTS/FANS UNLESS IT IS DEDICATED IN ONE BATHROOM ONLY. 6. PROVIDE A DEDICATED 20-AMP BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEPTACLE. CEC SEC. 210.11C2 7. ALL 120-VOLT, SINGLE PHASE, 15 AND 20-AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOM OR AREAS SHALL BE PROTECTED BY LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI), COMBINATION TYPE, AND TAMPER RESISTANT RECEPTACLES INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER 2016 CEC SEC. 210.12 AND 406.12 8. KITCHEN (HOOD) FAN SHALL HAVE A MIN. AIR FLOW OF 100 CFM. AND TO BE VENTED TO THE EXTERIOR 9. PROVIDE MECHANICAL VENTILATION AND APPLICABLE CONTROLS IN ALL ROOMS CONTAINING BATHING FIXTURES PER 2016 CRC R303.3, 2016 CMC AND 2016 CGBC SECTION 4.506 10. THE SWITCH TO TURN ON MASTER BATH VANITY LIGHTS TO BE ILLUMINATED TYPE. 11. SLEEVES SHALL BE PROVIDED TO PROTECT ALL PIPING THROUGH CONCRETE AND MASONRY WALLS AND CONCRETE FLOORS. CPC 313.10.1. 12. SMOKE ALARMS ARE REQUIRED TO BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS. 2016 CRC SEC. R314.5 13. OUTDOOR RECEPTACLES AT BOTH THE FRONT AND REAR OF THE HOME TO BE WITHIN 6 FEET 6 INCHES OF GRADE, WEATHERPROOF AND GFI PROTECTED (WP/GFI). CEC 210-52(E), 210-8(A)(3). 14. LIGHT FIXTURES IN TUB/SHOWER ENCLOSURES SHALL BE SUITABLE FOR DAMP LOCATIONS. 15. KITCHEN ENERGY COMPLIANCE FORMS WILL BE PROVIDED TO THE FIELD INSPECTOR PRIOR TO FINAL INSPECTION TO VERIFY HERS TESTING HAS BEEN COMPLETED AND LIGHTING PROVIDED PER THE ENERGY DESIGN DOCUMENTS. 16. IN ALL AREAS SPECIFIED IN 2016 CEC 406.12, ALL 125-VOLTS, 15 AND 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. 17. IN ALL AREAS SPECIFIED IN 2016 CEC 210.8(A), ALL 125-VOLT SINGLE PHASE, 15 AND 20-AMPERE RECEPTACLES IN THE LOCATIONS SPECIFIED SHALL HAVE (GFCI) GROUND FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL. INCLUDING THE GARAGE DOOR OPENER RECEPTACLE 18. A MIN. 1-INCH ELECTRICAL CONDUIT SHALL BE PROVIDED FROM THE ELECTRICAL SERVICE EQUIPMENT TO AN ACCESSIBLE LOCATION IN THE ATTIC OR OTHER LOCATION APPROVED BY THE BUILDING OFFICIAL. 19. AN APPROVED SEISMIC GAS SHUT-OFF DEVICE OR AN APPROVED EXCESS FLOW GAS SHUT-OFF DEVICE SHALL BE INSTALLED DOWNSTREAM OF THE GAS UTILITY METER AND EXCESS FLOW GAS SHUT-OFF DEVICES SHALL BE INSTALLED AT EACH GAS FUEL APPLIANCE OUTLET ON EACH FUEL GAS LINE WHERE THE GAS LINE SERVES ANY NEW BUILDING CONTAINING FUEL GAS PIPING . 20. SMOKE ALARMS SHALL BE REPLACED AFTER 10 YEARS FROM THE DATE OF MANUFACTURE MARKED ON EACH UNIT OR IF THE DATE CANNOT BE DETERMINED. ELECTRICAL NOTES MECHANICAL NOTES 1. MECHANICAL WORK SHALL BE DESIGNED AS-BUILT IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS, AND SHALL COMPLY WITH CA MECHANICAL CODE REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR SECURING SEPARATE MECHANICAL PERMIT. 2. FOR ATTIC MOUNTED MECHANICAL EQUIPMENT, PROVIDE SMOKE DETECTOR AND LIGHT WITH SWITCH LOCATED NEAR ACCESSORY, ELECTRIC RECEPTACLE, CATCH PAN WITH OVERFLOW. PROVIDE DOUBLE CEILING JOISTS TO SUPPORT 3/4" PLYWOOD CATWALK (36" DEEP, MIN., ADJACENT TO SERVICE SIDE OF EQUIPMENT). 3. WATER HEATER SHALL BE STRAPPED AND SECURED TO PREVENT ANY LATERAL MOVEMENT. 4. FACTORY BUILT FIREPLACES OR CHIMNEYS MUST BE LISTED BY THE MANUFACTURE AND INSTALLED IN ACCORDANCE WITH MANUFACTURE'S RECOMMENDATIONS. 5. COMBUSTION AIR FOR FUEL BURNING APPLIANCES SHALL BE OBTAINED FROM THE OUTSIDE. COMBUSTION AIR OPENING SHALL BE PROVIDED WITH A GALVANIZED SLEEVE OF NOT LESS THAN 26 GAUGE STEEL OR OTHER APPROVED MATERIAL EXTENDING FROM THE APPLIANCE ENCLOSURE TO AT LEAST SIX (6) INCHES ABOVE THE TOP OF CEILING JOISTS AND INSULATION. 6. AIR CONDITIONING EQUIPMENT DESIGNED INTO A FIXED POSITION SHALL BE SECURELY FASTENED. 7. DECORATIVE GAS APPLIANCES (FALSE FIREPLACES) SHALL BE IDENTIFIED WITH A LABEL INDICATING "GAS ONLY - NOT FOR WOOD BURNING. 8. VENT DRYER WITH SHEET METAL VENT TO OUTSIDE AS PER I.M.C. REQUIREMENTS. TERMINATION OF ALL AIR DUCTS SHALL BE AT LEAST 3' AWAY FROM OPENINGS INTO THE BUILDINGS AND PROPERTY LINES. 9. HEATING AND COOLING DUCTS SHALL BE INSULATED. 10. GAS APPLIANCES SHALL HAVE IGNITER TYPE PILOTS. 11. WATER HEATER SHALL BE VENTILATED PER SECTION 507. C.PC. OPENINGS SHALL BE LOCATED SO THAT ONE COMBUSTION AIR OPENING EXTENDS WITHIN THE UPPER TWELVE (12) INCHES (305 MM) OF THE APPLIANCE ENCLOSURE AND ONE COMBUSTION AIR OPENING EXTENDS WITHIN THE LOWER TWELVE (12) INCHES (305 MM) OF THE ENCLOSURE. REQUIRED COMBUSTION AIR DUCTS SHALL NOT BE LESS THAN THREE (3) INCHES (76 MM) IN THE LEAST DIMENSION. 12. PROVIDE MECHANICAL VENTILATION CAPABLE OF PROVIDING FIVE (5) AIR CHANGES PER HOUR IN BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS, AND SIMILAR ROOMS IF REQUIRED OPENABLE WINDOWS ARE NOT PROVIDED. (DUCTLESS) FANS ARE NOT ACCEPTABLE IN ROOMS CONTAINING TUBS OR SHOWERS. 13. HERS TESTING OF DUCT REQUIRED FOR NEW ADDITION IF DUCT LENGTH IS GREATER THAN 40'. RECESSED LIGHTING a. Where there there are recessed luminaires in insulated ceilings, amend the plans to specify IC rated, electronic ballast and Air-tight (AT) for such recessed luminaires. Recessed light fixtures in insulated ceilings shall be approved, listed, zero-clearance insulation cover (IC) Type, certified air tight (ASTE 282) and sealed with a gasket or caulked between housing and ceiling, and shall be certified to comply with Section 1199(N), and allow ballast maintenance and replacement to readily accessible to building occupants from below (CEC 150k12) Title 24 b. Recessed fixtures installed above shower stalls should be gasketed and suitable for a damp location . NEC Section 410-d c. Recessed lights or surface mounted - fluorescent lights in the closets shall be located to provide a minimum clearance of 6 inches between the fixture and the nearest point of a storage space. Surface mounted - incandescent lights can be within 12 inches. NEC Section 410-8 -(d)1-4. PLUMBING NOTES 1. PLUMBING WORK SHALL BE DESIGNED AND BUILT IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS AND SHALL COMPLY WITH UNIFORM PLUMBING CODE REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR SECURING SEPARATE PLUMBING PERMIT. 2. WATER SAVING DEVICES (TOILETS, SHOWER HEADS, AND FAUCETS) SHALL COMPLY WITH LOCAL ORDINANCES. 3. ALL WATER CLOSETS TO BE LOW FLOW (MAX. OF 1.28 GALS. / FLUSH) 4. ALL HOSE BIBBS (INTERNAL AND EXTERNAL) SHALL BE PROTECTED BY AN APPROVED NON-REMOVABLE TYPE BACK FLOW PREVENTION DEVICE. 5. ALL SHOWER COMPARTMENTS, REGARDLESS OF SHAPE SHALL +$9( $ 0,1,080 ,17(5,25 )/225 $5($ 2)  ,1ð $1' $5( CAPABLE OF ENCOMPASSING A 30" CIRCLE. 6. WATER HEATER (NEW OR EXISTING) SHALL BE INSTALLED 18" MIN. ABOVE THE GARAGE FLOOR. 7. RESIDENTIAL PLUMBING FIXTURES AND FITTINGS SHALL MEET THE STANDARDS BELOW a. KITCHEN SINK FAUCETS = 1.8 GPM MAX @ 60 PSI b. LAVATORY FAUCETS = 1.2 GPM MAX @60 PSI c. SHOWER HEADS = 2.0 GPM MAX @ 80 PSI DATE SCALE DRAWN BY DWG FILE SHEET REVISIONS BY Koi Design Services 1271 Washington Ave. #930 San Leandro, California 94577 (510) 282-0662 of ELECTRICAL PLAN / NOTES COSTANZO RESIDENCE 816 COTTONWOOD DR. CUPERTINO, CA. 95014 A-2 3 7 1 4"=1'-0" Electrical Plan 1 A-2 All ceiling sheetrocks shall remain existing. Do not remove or replace. Phuong Devries 05/23/17 (N) 6020 FX GRADE LOWER F.F. 0'-0" 1'-3" 9'-3" T.P. 13'-61 2" RIDGE (N) CLASS B SHINGLES MIN. (N) 6030 SL (E) 16070 GARAGE (N) 3020 SL (N) 3020 SL (N)3068 T.P. RIDGE GRADE LOWER F.F. 0'-0" 1'-3" 13'-61 2" VIF bottom of egress window opening is < 44" A.F.F. 9'-3" (N) CLASS B SHINGLES MIN. (E) INSET CONCRETE PORCH TO REMAIN (N) 6040 SL 9'-3" GRADE LOWER F.F. 0'-0" 1'-3" T.P. RIDGE 13'-61 2" (N)2868 (N) CLASS B SHINGLES MIN. GARAGE T.P. 8'-0" (N) 8068 SLIDER (N) 6030 SL (N) 6030 SL (N) 6030 SL T.P. RIDGE GRADE LOWER F.F. VIF bottom of egress window opening is < 44" A.F.F. 0'-0" VIF bottom of egress window opening is < 44" A.F.F. VIF bottom of egress window opening is < 44" A.F.F. 1'-3" 13'-61 2" 9'-3" (N) CLASS B SHINGLES MIN. (E) CONCRETE STOOP TO REMAIN DROPPED T.P. 8'-7" DATE SCALE DRAWN BY DWG FILE SHEET REVISIONS BY Koi Design Services 1271 Washington Ave. #930 San Leandro, California 94577 (510) 282-0662 of ELEVATIONS COSTANZO RESIDENCE 816 COTTONWOOD DR. CUPERTINO, CA. 95014 A-3 4 7 1 4"=1'-0" Rear Elevation 2 1 4"=1'-0" Right Elevation 1 1 4"=1'-0" Front Elevation 4 A-3 1 4"=1'-0" Left Elevation 3 A-3 A-3 A-3 Roofing material to be Class A minimum. Phuong Devries 05/23/17 DATE SCALE DRAWN BY DWG FILE SHEET REVISIONS BY Koi Design Services 1271 Washington Ave. #930 San Leandro, California 94577 (510) 282-0662 of TITLE 24 COSTANZO RESIDENCE 816 COTTONWOOD DR. CUPERTINO, CA. 95014 A-4 5 7 Sebastian Alfonso 05/17/17 Phuong Devries 05/23/17 DATE SCALE DRAWN BY DWG FILE SHEET REVISIONS BY Koi Design Services 1271 Washington Ave. #930 San Leandro, California 94577 (510) 282-0662 of TITLE 24 COSTANZO RESIDENCE 816 COTTONWOOD DR. CUPERTINO, CA. 95014 A-5 6 7 Phuong Devries 05/23/17 DATE SCALE DRAWN BY DWG FILE SHEET REVISIONS BY Koi Design Services 1271 Washington Ave. #930 San Leandro, California 94577 (510) 282-0662 of CUPERTINO BMP COSTANZO RESIDENCE 816 COTTONWOOD DR. CUPERTINO, CA. 95014 A-6 7 7 Phuong Devries 05/23/17 5'-0" 10'-0" 20'-0" 104.28' 132.06' 61.03 61.37 E (N) 200A MAIN (E) 4" C/O W (E) 3 4" WATER LINE G (E) 3 4" GAS MAIN (E) OH UTILITY LINE (E) RESIDENCE (E) GARAGE 135 SF KITCHEN REMODEL Driveway (E) NON CONFORMING SIDE 4.5' S/W 6.5' R/W + 6" CURB 21'-10" 20' FRONT SETBACK 20' REAR SETBACK 5' SIDE SETBACK 10' SIDE SETBACK (E) WATER MAIN DATE SCALE DRAWN BY DWG FILE SHEET REVISIONS BY Koi Design Services 1271 Washington Ave. #930 San Leandro, California 94577 (510) 282-0662 of COVER SHEET COSTANZO RESIDENCE 816 COTTONWOOD DR. CUPERTINO, CA. 95014 CS-1 1 7 CODES & STANDARDS SCOPE OF WORK AERIAL VIEW SHEET INDEX DIMENSIONS + 135 SF KITCHEN REMODEL TO INCLUDE: x REMOVE SOFFIT, CABINETS AND FIXTURES x (N) CABINETS & FIXTURES THROUGHOUT x (N) KITCHEN ISLAND x (N) APPLIANCES + RETROFIT ALL (E) WINDOWS + (N) EXTERIOR DOORS + UPGRADE (E) PANEL TO 200A + WHOLE HOUSE REWIRE TO REPLACE (E) 2 PRONG + (N) LIGHTING THROUGHOUT WHOLE HOUSE + (N) 30 YEAR ROOF, CLASS B SHINGLES MIN. 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA ENERGY EFFICIENCY STANDARDS SITE PLAN 7137 SF LOT AREA EXISTING LIVING AREA 1212 SF $31   A-1 FREE AREA SITE DATA OCCUPANCY CLASSIFICATION R3 CONSTRUCTION TYPE V-B YEAR BUILT 1960 ZONING R1-6 LOT AREA 7137 SF SETBACKS FRONT = 20' REAR = 25' SIDE = 5', AGGREGATE 15' MAX. SINGLE STORY HEIGHT = 28' 618 COTTONWOOD DR. 5370 SF OR 88% OWNER: JANETTE COSTANZO / RAY BROOKSBY (408)386-1193 CONTRACTOR: NATHAN WEIZMANN WISE BUILDERS (415)610-6155 DESIGNER: SEBASTIAN ALFONSO KOI DESIGN SERVICES (510) 282-0622 CONTACTS A-2 EXISTING / PROPOSED FLOOR PLANS A-3 ELEVATIONS PROPOSED TOTAL LIVING AREA 1212 SF ELECTRICAL / NOTES 2016 CALIFORNIA RESIDENTIAL CODE A-4 EXISTING ATTACHED GARAGE 471 SF TOTAL FOOTPRINT 1583 SF 2016 CUPERTINO MUNICIPAL CODE 1583 SF / 6953 SF CS-1 COVER SHEET VICINITY MAP (NO CHANGE TO EXISTING) 2 3 4 5 1 A-5 TITLE 24 6 TITLE 24 FOOTPRINT / NET LOT AREA (NO CHANGE TO EXISTING) A-6 7 CUPERTINO BEST MGMT. PRACTICES TABLE - MAX. FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL) 2.0 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL) MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.25 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.5 GAL/FLUSH A 05/23/17 B-2017-0811 Phuong Devries Abby Ayende 08/21/17 Abby Ayende 08/21/17 Abby Ayende 08/21/17 Abby Ayende 08/21/17 Abby Ayende 08/21/17