B-2016-1361CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS:
CONTRACTOR:
PERMIT NO: B-2016-1361
10208 LOCKWOOD DR CUPERTINO, CA 95014-2600 (342 14 041)
WING ON
CONSTRUCTION INC
SAN LEANDRO, CA
94579
OWNER'S NAME: DING RAN AND ZHANG YING
DATE ISSUED: 06/24/2016
OWNER'S PHONE:
PHONE NO: (510) 786-8838
LICENSED CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO:
License Class GENERAL BUILDING CONTRACTOR Lic. #949206
Contractor WING ON CONSTRUCTION INC Date 06/30/2018
X BLDG ELECT _PLUMB
— —
MECH X RESIDENTIAL COMMERCIAL
1 hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
— —
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
JOB DESCRIPTION:
CONSTRUCT (N) DETACHED 2ND UNIT (800 S.F.) WITH COVERED
I hereby affirm under penalty of perjury one of the following two declarations:
PORCH (240 S.F.)
1. 1 have and will maintain a certificate of consent to self -insure for Worker's
"FIRE SPRINKLERS REQUIRED"
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
2. 1 have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
Sq. Ft Floor Area: 1040
_
Valuation: $110000.00
permit is issued.
APPLICANT CERTIFICATION
certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
APN Number:
Occupancy Type:
and state laws relating to building construction, and hereby authorize
342 14 041
Deferred Submittal (R -3),R-3 (Custom)
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
PERMIT EXPIRES IF WORK IS NOT STARTED
may accrue against said City in consequence of the granting of this permit.
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
Additionally, the applicant understands and will comply with all non -point
source regulations per the Cupertino Municipal Code, Section 9.18.
180 DAYS FROM LAST CALLED INSPECTION.
Signature Date
Issued by: AbbyAvende
Date: 06/24/2016
OWNER -BUILDER DECLARATION
I hereby affirm that 1 am exempt from the Contractor's License Law for one of the
RE -ROOFS:
following two reasons:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
t. 1, as owner of the property, or my employees with wages as their sole
installed without first obtaining an inspection, I agree to remove all new materials for
compensation, will do the work, and the structure is not intended or offered for
inspection.
sale (Sec.7044, Business & Professions Code)
2. 1, as owner of the property, am exclusively contracting with licensed
Signature of Applicant:
contractors to construct the project (Sec.7044, Business & Professions Code).
Date:
I hereby affirm under penalty of perjury one of the following three declarations:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
r. 1 have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
HAZARDOUS MATERIALS DISCLOSURE
2. I have and will maintain Worker's Compensation Insurance, as provided for by i
1 have read the hazardous materials requirements under Chapter 6.95 of the
Section 3700 of the Labor Code, for the performance of the work for which this
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
permit is issued.
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
3. I certify that in the performance of the work for which this permit is issued, I
Health & Safety Code, Section 25532(a) should I store or handle hazardous
shall not employ any person in any manner so as to become subject to the
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
Worker's Compensation laws of California. If, after making this certificate of
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
exemption, I become subject to the Worker's Compensation provisions of the
the Health & Safety Code, Sections 25505, 25533, and 25534.
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
Owner or authorized agent:
APPLICANT CERTIFICATION
Date:
I certify that I have read this application and state that the above information is
CONSTRUCTION LENDING AGENCY
correct. I agree to comply with all city and county ordinances and state laws
I hereby affirm that there is a construction lending agency for the performance
relating to building construction, and hereby authorize representatives of this city
of work's for which this permit is issued (Sec. 3097, Civ C.)
to enter upon the above mentioned property for inspection purposes. (We) agree
Lender's Name
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
Lender's Address
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
ARCHITECT'S DECLARATION
Code, Section 9.18.
1 understand my plans shall be used as public records.
Signature Date
Licensed
Professional
CYPERTINQ
NPXV CYITTCTRTIr'TIC)N
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408-)^1777-3228 • FAX (408) 777-3333 • bull dinn1a(d)cupertino.org Z -0r C
1 !
I I Anr ITTn-IJ M AT TFR ATT1N 1 TT I rI RFVTRTnx / T)FRfi.RRFn CIRTC,TNAT. AF.RMTT t
PROJECTAD ss
APN # (J
G kwnd
7 G i D
OWNERNAME PLIONE
E-MAIL
STREET ADDRESS
CITY. STATE, ZIP
TFAX
6 c r
a +; 0 S�c7l
CONTACT NAME PHONE
E-MAIL
STREETADDRESS
CITY, STATE, ZIP
FAX
9 OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME
LICENSE NUMBER
LICENSE TYPE
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
Y o j�
ARCHITECT/EN'GINEERHAME Leo
Lc?Ve
LICENSE NUMBER
HUS. LIC #
C /
COMPANY NAME LC --L s_1
l ^��
E-MAIL
FAX
STREET ADDRESS
CITY STATE, ZIP'
CITY
CA E4,201
P ONE 6r7
DESCRIPTION OF WORK Al JN��J�}(rL(, /ld®' �YVR+/JYGVy 970
,
EXISTING USE
PROPOSED U E CONSTX
TYPE
# STORIES
)e
l,isq
t,
F
USE TYPE
OCC.
SQ.FT.
VALUATION (S)
MSTO
NEW FLO
DEMO.
TOTAL
AREA
AREA (J5
ARFA
NET AREA
BATHROOM KITCHEN
OTHER
REMODELAREA REMODEL AREA
REMODEL AREA
PORCH AREA
DECK AREA
TOTAL DECKIPORC
GARAGE AREA: LjDETACH
Z %10
[] ATTACH
# DWELLING UNITS:
IS A SECOND UNIT ❑ YES
SECOND STORY YES
BEING ADDED? NO
ADDITION? XNO
PRE -APPLICATION [] YES IF YES, PROVIDE COPY OF
IS THE BLDG AN
-
TOTAL VALUATION:
PLANTING APYL # ['7 NO PLANNING APPRO\+AL LETTER
EICHLER
VY -
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on rope ' mgr's behalf. I have read this
application and the information I have provided is correct. 1 have read the Description of Work and verify i ac agree to comply with all applicable local
ordinances and state laws relating to building construction, I authorize representatives of Cupertino to enter the above -identified roperty for inspection purposes.
Signature of Applicant/Agent: Date: ��/I 2oZ 016__
v
SUPPLEMENTAL INFORMATION REQUIREDPLAN
CHECi. IS'PE-:-,-
ROUTING SI IP
❑
RE\IER
_ NTety SFD or Multifamily dwellings: Apply for demolition permit for
existing building(s). Demolition pelmitis required prior to issuance of building
ovER TFIE cov\TERBUILDI\G
PLA\
permit for new building.
❑` Ex�Rless
iA\\L\c rLal. RE' iLR
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
sTA\DARD
PusiJc «oRts
foI-In if any Hazardous Materials are being used as part of this project.
❑_ LARGE
FIRE DEPT
_ Copy of Planning Approval Letter or Meeting with Planning prior to
Submittal of Building Permit application.
❑rL4JOR '
s\IrARlsE\\ ER DISTRICT
;
❑\VIRO\ArENTAL HEALTH `•=
Bld& 4pp_2011. doc revised 06/21/11
CITY OF CUPERTINO
FEE ESTIMATOR - BUILDING DIVISION
OCCUPANCY TYPE:
ADDRESS: 10201LOCKWOOD DR
DATE: 0 211 212 01 6
REVIEWED BY: MELISSA
PC FEE ID
APN: 342 14041
BP#:
*VALUATION: j$110,000
"PERMIT TYPE: Building Permit
PLAN CHECK TYPE: New Construction
PRIMARY SFD or Duplex
USE:
2nd Unit? Yes 0 No
PENTAMATION 1 R3SFD2ND
PERMIT TYPE:
WORK
CONSTRUCT N. DETACHED 2ND UNIT 800 S.F. WITH COVERED PORCH 240 S.F.
SCOPE
OCCUPANCY TYPE:
TYPE OF
CONSTR.
FLR AREA
s.f.
PC FEES
PC FEE ID
BP FEES
BP FEE ID
R-3 (Custom)
II-I3,111-B,IV,V-B
1,040
$2,674.63
IR3PLNCK
$1,739.91
1R311VSP
$Q.00
PME Plan Check:
$0.00
Permit Fee:
$1,739.91
Suppl. Insp. Fee:Q Reg. Q OT
0.0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
TOTALS:
1,040
$2,674.63
Construction Tax_ IBCONSTAXR
$1,739.91
-
NOTE. This estimate does not include fees due to other Departments (I. e. Planning, Public Works, Fire, Sanitary Server District, School
District, etc.). These fees are based on the nreliminary information available and are only an estimate. Contact lite Dent for addn'l infix.
FEE ITEMS (1,ee Resolution 11-053 £ff. 711113)
il,:-,.`fi. May! Ch, 1-A-
71e?ce
lilt"'. Plan ('f}F'.i.'ti
ifecA i'erFrt;i F, e
Plan Check Fee:
c:.. ..,i..s C •
�"�s).
.?.
i.)i*A Iir!C:. 6 !,
f ee:
Suppl. PC Fee: (E) Reg. 0 OT
10.01
NOTE. This estimate does not include fees due to other Departments (I. e. Planning, Public Works, Fire, Sanitary Server District, School
District, etc.). These fees are based on the nreliminary information available and are only an estimate. Contact lite Dent for addn'l infix.
FEE ITEMS (1,ee Resolution 11-053 £ff. 711113)
FEE
QTYIFEE
MISC ITEMS
Plan Check Fee:
$2,674,63
Select a Mise Bldg/Structure
or Element of a Building
i
Suppl. PC Fee: (E) Reg. 0 OT
10.01
hrs
$Q.00
PME Plan Check:
$0.00
Permit Fee:
$1,739.91
Suppl. Insp. Fee:Q Reg. Q OT
0.0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
Construction Tax_ IBCONSTAXR
1
N new
units
$689.97
. iti?itf't?d.5`i7'ct"t11-e? 1't?c.':
0
E)
Work Without Permit? (D Yes (B No
$0.00
7+dryLinced Planning 1'ee:
IPLLONGR
$145.60
Select a Nan -Residential
Building or Structure
G
7:�^i,a�e:r' 1Jc�sta�r;er�fe,etl�>vt I��e,�:
Sfrong .Motion Fee:
IBSEISMICR
$14.30
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$5.00
-SUBTOTALS;
$5,269.41
$0.00
TOTAL:FEE: $5,269.41
Revised: 01/0112016
CONTRACTOR / SUBCONTRACTOR LIST
Building Department
City Of Cupertino
10300 Torre Avenue,
Cupertino, CA 95014-3255
Telephone: 408-777-3228
Fax: 408-777-3333
JOB ADDRESS:
PERMIT #
OWNER'S NAME: b> `ayL
PHONE #
GENERAL CONTRAC ORM 4 sle-,
BUSINESS LICENSE # 20
ADDRESS: ,
CITY/ZIPCODE:
*Our municipal code requires all businesses working in the city to have a City of Cupertino busine s license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRA TORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors:' C C2e f
j' ignature Date
Please check applicable subcontractors and complete the following information:
Owner / Contractor Signature Date
SUBCONTRACTOR
BUSINESS NAME
BUSINESS LICENSE #
Cabinets & Millwork
Cement Finishing
Electrical
Excavation
Fencing
Flooring / Carpeting
Linoleum / Wood
Glass / Glazing
Heating
Insulation
Landscaping
Lathing
Masonry
Painting / Wallpaper
Paving
Plastering
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
Owner / Contractor Signature Date
CUPERTINO
N
Owner Name Dl t j
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3228 - FAX (408) 777-3333 - building(6 cupertino.org
Address / d oZ 0 d
1. Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of fonn.
XNo Go to Question 2.
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
,jitubing, installation of water -conserving plumbing fixtures is not technically feasible?
Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the fonn and sign bottom of fonn.
T0 Go to Question 3.
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of fonn.
KNO Go to Question 4.
4. Is your real property built and available for use or occupancy on or before January 1, 1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the fonn and sign bottom of fonn.
KYes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
Please check ONE of the following:
My property is a single- fancily residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
property undergoes alterations or improvements).
❑ My property is a multifamily residential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or irmprovernents shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-coinpliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a comncercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conseiving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements).
I, as the owner or owner's agent of this property, certify under penalty of peijuiy that non-compliant plumbing fixtures will be
replaced prior to date specified above with Neater -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1
through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's
installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the
table on the following pace. ,,— „ / . . _ i r,
Owner or Owner Agent's Signature: Date: -1,
Upon completing and signing this Cerrif c te, please return it to the Building Division in order to final your building permit. --�
SB4072015.doc revised 01;05117
Non -Compliant
Water -Conserving Plumbing Fixture
Plumbing Fixture
(Fixture Complying with Current Code Applicable to New Construction)
Maximum Water Usage/Flow Rate
Fixture Type
Water Usage
2016 CPC Ch. 4
2016 CPC Ch. 4
2016 CPC Ch. 4
/Flow Rate
2016 CALGreen Div. 4.3
2016 CALGreen Div. 4.3
2016 CALGreen Div. 5.3
Single-Family
Multi-Family
Commercial
Residential
Residential
Water Closets
Exceed 1.6
Single flush toilets: 1.28 gallons/flush
(Toilets)
Gallons/flush
Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite,
average flush volume of two reduced flushes and one full flush
Urinals
Exceed 1.0
0.5 gallons/flush
Gallons/flush
Showerheads
Exceed 2.5
2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of
gallons per minute
U.S. EPA WaterSense Specification for Showerheads
(A hand-held shower is considered a showerhead.)
For multiple showerheads serving one shower, the combined flow rate of all
showerheads and/or other shower outlets controlled by a single valve shall not
exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to
allow only one shower outlet to be in operation at a time.
Faucets —
Exceed 2.2 gallons
Maximum 1.5 gallons per
Within units:
0.5 gallons per minute @ 60
Lavatory
per minute
minute @ 60 psi; minimum
Maximum 1.5 gallons
psi
Faucets
0.8 gallons per minute @
per minute @ 60 psi;
20 psi
minimum 0.8 gallons
per minute @ 20 psi
In common and public
use areas: 0.5 gallons
per minute @ 60 psi
1.8 gallons per minute
60 " si::.,
Faucets —
Exceed 2.2 gallons
1.8 gallons per minute @
1.8 gallons per minute
1.8 gallons per minute @ 60
Kitchen
per minute
60 psi
@- 60 psi
psi
Faucets
May temporarily increase
May temporarily
up to 2.2 gallons per
increase up to 2.2
minute @ 60, psi, and must
gallons per minute @
default to maximum
60 psi, and must
1.8 gallons per minute @
default to maximum
60 psi
1.8'gallons per minute
Where faucets meeting
@ 60 ,psi'r
the above'are unavailable,
Where faucets meeting
aerators or other means
the above are
maybe used to achieve
unavailable, aerators or
reduction.
other means'may be :=
used to achieve
reduction. -: ;_
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_2nd.xml
CF1 R -PRF -01
Page 1 of 8
GENERAL INFORMATION
01
Building Complies with Computer Performance'
01
Project Name Ding's 2nd Unit New Residence
03
This building incorporates one or more Special Features shown below
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ftz-yr)
03
Project Location 10206 Lockwood Drive
Compliance Margin
Percent Improvement
04
City Cupertino
05
Standards Version Compliance 2015
06
Zip Code 95014
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ4
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ftz) 800
15
Number of Zones 1
16
Slab Area (ftz) 0
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (ftz) N/A
21
Glazing Percentage (%) 20.8%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance'
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
06
Cup�RT-NO -
--Bu--dlna Department
F EF 3 CODE -COMM A"NCE-
Registration Number: 216-N0054875A-000000000-0000 Registration ate � Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
v e By -d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11C352015 744 Report Generated at: 2016-02-09 11:32:10
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftz-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
11.36
13.02
-1.66
-14.6%
Space Cooling
21.23
29.01
-7.78
-36.6%
IAQ Ventilation
1.77
1.77
0.00
0.0%
Water Heating
27.11
13.69
13.42
49.5%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
61.47
57.49
3.98
6.5%
Cup�RT-NO -
--Bu--dlna Department
F EF 3 CODE -COMM A"NCE-
Registration Number: 216-N0054875A-000000000-0000 Registration ate � Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
v e By -d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11C352015 744 Report Generated at: 2016-02-09 11:32:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Input File Name: Ding_10206_Lockwood_2nd.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
CF1 R -PRF -01
Page 2 of 8
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
Minimum Airflow
Verified EER
Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6(such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 139.26 135.28 3.98 2.9%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Ding's 2nd Unit New Residence
800
1
2
1
0
1
ZONE INFORMATION
01
02
03 04
05
06
07
Zone Name
Zone Type
Zone Floor Area
HVAC ime _ 2
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st Floor
Conditioned
A
800
8
DHW Sys 1
RFx1IF - P CODE -COMM Ag F
Registration Number: 216-N0054875A-000000000-0000 Registration ate Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11C352015 744 Report Generated at: 2016-02-09 11:32:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_2nd.xml
CF1 R -PRF -01
Page 3 of 8
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ftz)
Tilt (deg)
1st Front Wall
1st Floor
R-13 Wall
180
Front
172
60
90
1st Left Wall
1st Floor
R-13 Wall
270
Left
320
29
90
Rear Wall
1st Floor
R-13 Wall
0
Back
172
16
90
1st Right Wall
1st Floor
R-13 Wall
90
Right
320
81
90
Roof
1st Floor
R-30 Roof Attic
Insect Screen (default)
Kitchen Window
800
1st Left Wall (Left -270)
6.0
Raised Floor
1st Floor
R-19 Floor Crawlspace
1.06
0.65
800
BedRm1 RearWindow
Window
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic 1st Floor Attic Roof1st Floor Ventilated 4 0.1 0.85 No No
WINDOWS
01
02
03
04
05
06;
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipli
er
Area
(ftz)
U -factor
SHGC
Exterior Shading
Living FWindow
Window
1st Front Wall (Front -180)
6.0
6.7
1.001
40.0
0.31
0.28
Insect Screen (default)
BathRm1 Window
Window
1st Left Wall (Left -270)
2.0
2.0
1
4.0
0.31
0.28
Insect Screen (default)
BathRm2 Window
Window
1st Left Wall (Left -270)
2.0
2.0
1
4.0
0.31
0.28
Insect Screen (default)
Kitchen Window
Window
1st Left Wall (Left -270)
6.0
3.5
1
21.0
1.06
0.65
Insect Screen (default)
BedRm1 RearWindow
Window
Rear Wall (Back -0)
2.0
4.0
1
8.0
0.31
0.28
Insect Screen (default)
HallWay Window
Window
Rear Wall (Back -0)
2.0
4.0
1
8.0
0.31
0.28
Insect Screen (default)
BedRm1 RtWindow
Window
1st Right Wall (Right -90)
6.0
4.5
1
27.0
0.31
0.28
Insect Screen (default)
BedRm2 Window
Window
1st Right Wall (Right -90)
6.0
4.0
1
24.0
0.31
0.28
Insect Screen (default)
Living RtWindow
Window
1st Right Wall (Right -90)
3.0
5.0
1
15.0
0.31
0.28
Insect Screen (default)
Living RtWindow 2
Window
1 st Right Wall (Right -90)
3.0
5.0
1
15.0
1 0.31
0.28
Insect Screen (default)
CUP�RT-NO -
--Bu--dlna Department
F EF g CODE -COMM A"NCE-
Registration Number: 216-N0054875A-000000000-0000 Registration ate � Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
v e By -d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11C352015 744 Report Generated at: 2016-02-09 11:32:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_2nd.xml
CF1 R -PRF -01
Page 4 of 8
DOORS
01 02
03 04
Name Side of Building
Area (ftz) U -factor
Kitchen Door 1st Front Wall
20.0 0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
Living FWindow
0
0
0
0
0
0
0
0
0
0
0
0
0
BathRm1 Window
0
0
0
0
0
0
0
0
0
0
0
0
0
BathRm2 Window
0
0
0
0
0
0
0
0
0
0
0
0
0
Kitchen Window
0
0
0
0
0
0
0
0
0
0
0
0
0
BedRm1 RearWindow
0
0
0
0
0
0
0
0
0
0
0
0
0
HallWay Window
0
0
0
0
0
0
0
0
0
0
0
0
0
BedRm1 RtWindow
0
0
0
0
0
0
0
0
0
0
0
0
0
BedRm2 Window
0
0
0;
0
0
0
0
0
0
0
0
0
0
Living RtWindow
0
0
0
0
0
0
0
0
0
0
0
0
0
Living RtWindow 2
0
0
0
0
0
0
0
0
0
0
0
0
0
CUP�RT-NO -
--Bu--dlna Department
RF EF g CODE -COMM A"NCE-
Registration Number: 216-N0054875A-000000000-0000 Registration ate � Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11052015 744 Report Generated at: 2016-02-09 11:32:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Input File Name: Ding_10206_Lockwood_2nd.xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Total Cavity
Winter Design
Input Rating
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
0.2
0.96
152000-Btu/hr
0
0
Cavity/ Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
Tile Gap: present
Attic Roofl st Floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.400
Roofing: 10 PSF (RoofTile)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-30 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
Over Floor Joists: R-20.9 insul.
Inside Finish: Gypsum Board
Cavity/Frame: R -13/2x4
Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
Floor Surface: Carpeted
Floors Over
Floor Deck: Wood Siding/sheathing/decking
R-19 Floor Crawlspace
Crawlspace
Wood Framed Floor
2x6 @ 16 in. O.C.
R 19
0.049
Cavity/Frame: R -19/2x6
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
WATER HEATING SYSTEMS
01
01
02 03 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/1
DHW Pipe Insulation, All Lines DHW Heater 1 1 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small In
-- -
0.2
0.96
152000-Btu/hr
0
0
WBu--dlna Department
F EF 3 CODE -COMM A"NCE-
Registration Number: 216-N0054875A-000000000-0000 Registration ate � Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11C352015 744 Report Generated at: 2016-02-09 11:32:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Input File Name: Ding_10206_Lockwood_2nd.xml
CF1 R -PRF -01
Page 6 of 8
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
---
---
---
Cooling Component 1
SplitAirCond
12.2
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC1
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 94.1 AFUE
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
Name
Verified Airflow
Efficiency
Verified EER
Multi -speed
Verified Refrigerant
Charge
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
12.2
14
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Not Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
04
05
06
07
Name
Type
Du
UI Nee
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Seal
a - I ��f
Attic
None
Air Distribution System
1 -hers -dist
F EF 3 CODE -COMM A"NCE-
Registration Number: 216-N0054875A-000000000-0000 Registration ate � Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11C352015 744 Report Generated at: 2016-02-09 11:32:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Input File Name: Ding_10206_Lockwood_2nd.xml
CF1 R -PRF -01
Page 7 of 8
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
---
HVAC-FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan Required 0.58
IAQ (Indoor Air Quality) FANS
01
02 '
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
30.5
0.25
Default
0
Required
CUP�RT_NO
Buii-ding Department
F EF 3 CODE -COMM A"NCE-
Registration Number: 216-N0054875A-000000000-0000 Registration ate � Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF1IC352015 744 Report Generated at: 2016-02-09 11:32:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's 2nd Unit New Residence Calculation Date/Time: 11:31, Tue, Feb 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_2nd.xml
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Mark Chu�"�'�
Company:
Signature Date:
Mark Chu & Associates
2016-02-10 23:02:45
Address:
CEA/HERS Certification Identification (If applicable):
1141 S. Stelling Rd.
City/State/Zip:
Phone:
Cupertino, CA 95014
408-255-4804
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Leo Li
Company:
Date Signed:
LEL Design
2016-02-11 00:33:42
Address:
License:
21701 Stevens Creek Blvd. # 32
NA
City/State/Zip:
Phone:
Cupertino, CA 95015
408-657-9928
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure tl f this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
--Bu--dlna Department
F EF 3 CODE- � ��M A` F
Registration Number: 216-N0054875A-000000000-0000 Registration ate Time: 2016-02-11 00:33:42 HERS Provider: CaICERTS inc.
rev e y -d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Reporersion `CF11C352015 744 Report Generated at: 2016-02-09 11:32:10
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(1):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF 1 R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8(g).
150.0
§ (q)
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system pir
er buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal di
4 incI ,1 i ssociated with a domestic hot water recirculation system
§ I50.00)2A:
regardless of the pipe diameter, pi
, g f
he lied ing source to s orage tank or between tanks, piping buried below grade, and
all hot water pipes from the heatin
i
according to the requirements of TABLE 120.3-
A.
§150.0(j)2B:
mustAll be installed in a waterproof and non -crushable casing or sleeve
that allowsdomestic
installation, remova ai buried l t °e cd�° Mrd insulation.
Da°tt,�P yy>f�,,,,'y>f'�
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3 -A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 18113 or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflo
g
ontir I itrcation and diagnostic testing, in accordance with
BEL,
Reference Residential Appendix
IIL114.
Pool and Spa Heating Systems and Equipment M
110.4(a):
Any pool p gsystem l� I W luf�a „y that complies with the Appliance Efficiency
��� � � ging
tel
)II. �'°: I t the the heater the thermostat
Re Regulations; the
§
an on-off switch mounted out�te of eater n an loisi shut off without adjusting
setting; a permanent weathe root)" 11th d'.� � �
g p rp r m�� i i Q !&i��i g and shall not use electric resistance heating.
1
V)atEE"
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of §150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§ I50.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§I50.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§I50.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of §130.5; and all other requirements in §150.0(k)2.
§ I50.0(k)2L•
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential build or lighting ermanentl mounted to a residential building or other buildings on the
same lot shall be high efficacy, or i eff mei t he following requirements:
i. N the automatic actions of Items ii or iii below; and
,,the
ln' hII� S t eIr It l ,
�eY
150.0(k)9A:
§y
ii Coontrooll db a motionOs sensor overri yp� ss switc disables the motion sensor, or controlled by a
motion sensor having a temporary itch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor with ,"PWE�°BOO E ����'IlJAN
iii. Controlled by one of the following methods: I �.
Reweweu t5y-1,11. u.... �11!11
V.)a°lt"Pyaf yaf'�
2013 Low -Rise Residential Mandatory Measures Summary
I110 lItt l I1I1 IIS
BufldhiigDeparturent
FREVH.�.WED FDR CODE COWI[JANCE
Rev tew d By:4 I....C:°1.f
DatE< P 5/f!::,,'5f'�
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ I50.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§ I50.0(k)l 1:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § I10.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)l :
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l :
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and perman _ , d as "For Future Solar Electric".
I110 lItt l I1I1 IIS
BufldhiigDeparturent
FREVH.�.WED FDR CODE COWI[JANCE
Rev tew d By:4 I....C:°1.f
DatE< P 5/f!::,,'5f'�
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Ding's 2nd Unit New Residence
2/10/2016
System Name
Floor Area
HVAC
800
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 425
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 37,000
8,812
449
195
9,681
Total Output (Btuh) 37,000
0
Output (Btuh/sqft) 46.3
400
538
Cooling System
0
0
Output per System 23,700
0
0 0
0
Total Output (Btuh) 23,700
0
449
0
Total Output (Tons) 2.0
400
538
Total Output (Btuh/sqft) 29.6
Total Output (sgft/Ton) 405.1
1 9,611
10,756
Air System
CFM per System
500
HVAC EQUIPMENT SELECTION
Airflow cfm
500
Carrier58MVB060-14 CNP 38HD 2 T
22,014
512
37,000
Airflow (cfm/sqft)
0.63
Airflow (cfm/Ton)
253.2
Outside Air (%)
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
22,014
512
Aug 3 PM
37,000
Outside Air (cfm/sqft) 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
28 OF
67 OF
115 1'::'115 1'::r
10
Outside Air
0 cfm
Heating Coil Supply Fan
500 cfm
ROOM
67 °F
_.... ..................................................... 68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
88/t',8ol:::
76/62°F 55/54°F 55/54°F
r
ir
Outside AAr
0 cfm
Cooling Coil Supply Fan
56 / 54 OF
500 cfm
46.3
2
76 / 62 "1::::::
��MCparturen't
...........................................................................
" / i'i
UII�III
EnergyPro 6.7 by EnergySoft
User Number: 49 70 [3 EVA If i V'4VR4 I iK'20 i U1* .' E
ID: 020116
Page 5 of 5
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 1 of 13
GENERAL INFORMATION
01
Building Complies with Computer Performance'
01
Project Name Ding's Main Residence (Existing+Addition)
03
This building incorporates one or more Special Features shown below
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 10206 Lockwood Drive
Compliance Margin
Percent Improvement
04
City Cupertino
05
Standards Version Compliance 2015
06
Zip Code 95014
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ4
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 270
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 3053.4
15
Number of Zones 2
16
Slab Area (ft2) 12190
17
Number of Stories 1
18
Addition Cond. Floor Area 863.4
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 0
21
Glazing Percentage (%) 19.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance'
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
06
Cup�RT-NO -
--Bu--dlna Department
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
25.07
24.78
0.29
1.2%
Space Cooling
13.02
12.46
0.56
4.3%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
9.94
6.16
3.78
38.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
48.03
43.40
4.63
9.6%
Cup�RT-NO -
--Bu--dlna Department
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition)
Calculation Description: Title 24 Analysis
Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Input File Name: Ding_10206_Lockwood_Main.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Ceiling has high level of insulation
Window overhangs and/or fins
HERS FEATURE SUMMARY
CF1 R -PRF -01
Page 2 of 13
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• --None --
Cooling System Verifications:
• --None --
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• --None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 91.15 86.52 4.63 5.1%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Zone Floor Area
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Ding's Main Residence
3053.4
1
5
2
0
1
(Existing+Addition)
8.75
DHW Sys 1
ZONE INFORMATION
01
02
03 04
05
06
07
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Type
HVACme -- 2
Height
Water Heating System 1
Water Heating System 2
Existing Floor
Conditioned
na 2190
8.4
DHW Sys 1
Additiom Floor
Conditioned
\ 863.4
8.75
DHW Sys 1
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 3 of 13
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
Existing Front Wall
Existing Floor
R-11 Wall
270
Front
356.5
94.6035
90
Existing
No
Existing Rear Wall
Existing Floor
R-11 Wall
90
Back
350
118.207
90
Existing
No
Existing Left Wall
Existing Floor
R-11 Wall
0
Left
588
129
90
Existing
No
Existing Right Wall
Existing Floor
R-11 Wall
180
Right
432
50.5
90
Existing
No
Interior Surface
Existing Floor»_Garage_
R-0 Wall
0.33
18.43
144
0
0.07
Existing
No
Interior Surface 2
Existing Floor»_Garage_
R-0 Wall
Left
179
184
0
0.33
Existing
No
Existing AtticRoof 2
Existing Floor
R-11 Roof Attic
N/A
2008.3
Cathedrali
Existing
No
Addition Rear Wall
Additiom Floor
R-15 Wall
90
Back
159
60
90
New
N/A
Addition Left Wall
Additiom Floor
R-15 Wall
0
Left
394
90
90
New
N/A
Addition Right Wall
Additiom Floor
R-15 Wall
180
Right
408
76
90
New
N/A
Addition Roof
Additiom Floor
R-38 Roof Attic
863.4
New
N/A
Raised Floor (Revision)
Additiom Floor
R-19 Floor Crawlspace
863.4
New
N/A
GarageFrontWall
_Garage_
Garage Ext Wall -
270
Front'
144
112
90
Existing
No
GarageRightWall
_Garage_
Garage Ext. Wall
180
Right
184
28
90
Existing
No
GarageRoof
_Garage_
R-0 Roof Attic
414
Existing
No
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
12
13
Roof
Framin
Verified
Orientatio
Area
Skylight
Roof Rise
Roof
Roof
Reflectan
Roof
g
Existing
Name
Zone
Type
n
(ft2)
Area (ft2)
(x in 12)
Pitch
Tilt(deg)
ce
Emittance
Factor
Status
Condifion
Existing AtticRoof
Existing Floor
R-11 Roof Attic1
Left
2.8
2.7
4
0.33
18.43
0.1
0.85
0.07
Existing
No
Existing CathedralRoof
Existing Floor
R-38 Roof
Left
179
0
4
0.33
18.43
0.1
i
0.85
0.1
Altered
N/A
Cathedrali
W�- -
Buii-ding Department
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 4 of 13
ATTIC
01
02
03
04
05
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
Eng ti
Attic
Attic Garage Roof Cons
Ventilated
4
0.1
0.85
No
No
No
_Garage_
Engti
Attic Existing Floor
Attic RoofExisting Floor
Ventilated
4
0.1
0.85
No
No
No
Attic Additiom Floor
Attic RoofAdditiom Floor
Ventilated
4
0.1
0.85
No
No
New
No
CUP�RT-NO -
--Bu--dlna Department
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 5 of 13
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft2)
LI -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
BedRm3 Window
Existing Front Wall (Front -270)
5.0
4.0
1
20.0
0.51
0.61
Insect Screen (default)
Existing
No
StudyRm Window
Existing Front Wall (Front -270)
5.0
4.0
1
20.0
0.51
0.61
Insect Screen (default)
Existing
No
LivingRm FWindow
Existing Front Wall (Front -270)
3.0
5.8
1.003
17.3
0.31
0.30
Insect Screen (default)
Altered
N/A
LivingRm FWindow 2
Existing Front Wall (Front -270)
3.0
5.8
1.003
17.3
0.31
0.30
Insect Screen (default)
Altered
N/A
MBedRm SI -Door
Existing Rear Wall (Back -90)
6.0
1 6.7
1 1.001
40.0
0.31
0.30
Insect Screen (default)
Altered
N/A
MBath RearWindow
Existing Rear Wall (Back -90)
3.0
3.0
1
9.0
0.31
0.30
Insect Screen (default)
Altered
N/A
LivingRm RWindow(Revision
Existing Rear Wall (Back -90)
3.0
5.8
1.003
17.3 _
0.39
0.37
Insect Screen (default)
Altered
N/A
LivingRm RWindow(Revision 2
Existing Rear Wall (Back -90)
3.0
5.8
1.003
17.3 _
0.39
0.37
Insect Screen (default)
Altered
N/A
LivingRm RWindow(Revision 3
Existing Rear Wall (Back -90)
3.0
5.8
1.003
17.3 _
0.39
0.37
Insect Screen (default)
Altered
N/A
LivingRm RWindow(Revision 4
Existing Rear Wall (Back -90)
3.0
5.8
1.003
17.3 _
0.39
0.37
Insect Screen (default)
Altered
N/A
BedRm2 Window
Existing Left Wall (Left -0)
6.0
4.5
1
27.0
0.51
0.61
Insect Screen (default)
Existing
No
MCloset Window
Existing Left Wall (Left -0)
4.0
3.0
1 `
12.0
0.51
0.61
Insect Screen (default)
Existing
No
Kitchen SLD (Revision)
Existing Left Wall (Left -0)
6.01
7.5
1
45.0 _
0.31
0.30
Insect Screen (default)
Altered
N/A
Kitchen SLD (Revision) 2
Existing Left Wall (Left -0)
6.0
7.5
1
45.0 _
0.31
0.30
Insect Screen (default)
Altered
N/A
Family Window
Existing Right Wall (Right -180) '
3.0
4.0
1 '
12.0
0.31
0.30
Insect Screen (default)
Altered
N/A
Family Window 2
Existing Right Wall (Right -180)
3.0
4.0
1
12.0
0.31
0.30
Insect Screen (default)
Altered
N/A
Kitchen Window
Existing Right Wall (Right -180)
4.0
4.5
1
18.0
0.31
0.30
Insect Screen (default)
Altered
N/A
MBath RtWindow
Existing Right Wall (Right -180)
2.0
2.0
1
4.0
0.31
0.30
Insect Screen (default)
Altered
N/A
Closet Window
Existing Right Wall (Right -180)
1.5
3.0
1
4.5
0.31
0.30
Insect Screen (default)
Altered
N/A
SunTunnel 11 R
Existing AtticRoof (Left -0)
----
----
1
2.7
0.42
0.26
None
New
N/A
BedRrm5 Window
Addition Rear Wall (Back -90)
4.0
5.0
1
20.0
0.31
0.30
Insect Screen (default)
New
N/A
BedRrm5 Window 2
Addition Rear Wall (Back -90)
4.0
5.0
1
20.0
0.31
0.30
Insect Screen (default)
New
N/A
Galary SLD (Revision)
Addition Left Wall (Left -0)
6.0
7.5
1
45.0
0.39
0.37
Insect Screen (default)
New
N/A
Galary SLD (Revision) 2
Addition Left Wall (Left -0)
6.0
7.5
1
45.0
0.39
0.37
Insect Screen (default)
New
N/A
MBdRm Window (Revision)
Addition Right Wall (Right -180)
6.0
4.0
1
24.0
0.31
0.30
Insect Screen (default)
New
N/A
Bath4 Window
Addition Right Wall (Right -180)
2.0
1
6.0
0.31
0.30
Insect Screen (default)
New
N/A
BedRm4 Window
Addition Right Wall (Right -180)
4. U
R _
.0
0.31
0.30
Insect Screen (default)
New
N/A
Bath5 Window
Addition Right Wall (Right -1 80)0.31
0.30
Insect Screen (default)
New
N/A
MBdRm5 Window
Addition Right Wall (Right -180)
_
4.0
1
8.0
0.31
0.30
Insect Screen (default)
New
N/A
lFP r D -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion €CF11 04u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 6 of 13
MBdRm5 Window 2 Addition Right Wall (Right -180) 2.0 4.0 1 1 1 8.0 1 0.31 1 0.30 Insect Screen (default) New N/A
DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft)
U -factor
Status
Verified Existing Condition
Entry Door
Existing Front Wall
20.0
0.50
Existing
No
Door
Addition Rear Wall
20.0
0.50
New
No
CUP�RT-NO -
--Bu--dlna Department
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 7 of 13
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up Dist R
Bot Up
BedRm3 Window
0
0
0
0
0
0
0
0
0
0
0
0
0
StudyRm Window
0
0
0
0
0
0
0
0
0
0
0
0
0
LivingRm FWindow
0
0
0
0
0
0
0
0
0
0
0
0
0
LivingRm FWindow 2
0
0
0
0
0
0
0
0
0
0
0
0
0
MBedRm SI -Door
0
0
0
0
0
0
0
0
0
0
0
0
0
MBath RearWindow
0
0
0
0
0
0
0
0
0
0
0
0
0
LivingRm RWindow(Revision
0
0
0
0
0
0
0
0
0
0
0
0
0
LivingRm RWindow(Revision 2
0
0
0
0
0
0
0
0
0
0
0
0
0
LivingRm RWindow(Revision 3
0
0
0
0
0
0
0
0
0
0
0
0
0
LivingRm RWindow(Revision 4
0
0
0
0
0
0
0
0
0
0
0
0
0
BedRm2 Window
0
0
0
0
0
0
0
0
0
0
0
0
0
MCloset Window
0
0
0°
0
0
0
0
0
0
0
0
0
0
Kitchen SLD (Revision)
0
0
0
0
0
0
0
0.
0
0
0
0
0
Kitchen SLD (Revision) 2
0
0
0
0
0
0
0
0
0
0
0
0
0
Family Window
0
0
0
0
0
0
0
0
0
0
0
0
0
Family Window 2
0
0
0
0
0
0
0
0
0
0
0
0
0
Kitchen Window
0
0
0
0
0
0
0
0
0
0
0
0
0
MBath RtWindow
0
0
0
0
0
0
0
0
0
0
0
0
0
Closet Window
0
0
0
0
0
0
0
0
0
0
0
0
0
BedRrm5 Wlndow
0
0
0
0
0
0
0
0
0
0
0
0
0
BedRrm5 Wlndow 2
0
0
0
0
0
0
0
0
0
0
0
0
0
Galary SLD (Revision)
0
0
0
0
0
0
0
0
0
0
0
0
0
Galary SLD (Revision) 2
0
0
0
0
0
0
0
0
0
0
0
0
0
MBdRm Window (Revision)
0
0
0
0
0
0
0
0
0
0
0
0
0
Bath4 Window
0
0
0
0
0
0
0
0
0
0
0
0
0
BedRm4 Window
0
0
00
0
0
0
0
0
0
0
0
Bath5 Window
0
0
0
-
0
0
0
0
0
0
0
MBdRm5 Window
0
0
0
-
0
0
0
0
0
0
0
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion €CF11 04u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016 Page 8 of 13
Calculation Description: Title 24 Analysis Input File Name: Ding_10206_Lockwood_Main.xml
CUP�RT-NO-
Bu--dlna Department
E EF R CODE -COMM Ag
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF1f C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 9 of 13
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Inside Finish: Gypsum Board
Cavity/ Frame: no insul. / 2x4
Exterior Finish: Wood
Garage Ext Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.302
Siding/sheathing/decking
Ceilings (below
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/ Frame: no insul. / 2x4
Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting Floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-11 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 11
0.081
Over Floor Joists: R-1.9 insul.
Inside Finish: Gypsum Board
Cavity/Frame: R -11/2x4
Roof Deck: Wood Siding/sheathing/decking
R-11 Roof Atticl
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 11
0.085
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Cavity/Frame: R -11/2x4
Exterior Finish: Wood
R-11 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 11
0.103
Siding/sheathing/decking
Inside Finish: Gypsum Board
Cavity/ Frame: no insul. / 2x4
R-0 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
Inside Finish: Gypsum Board
Cavity/ Frame: R-38 / 2x12
Roof Deck: Wood Siding/sheathing/decking
R-38 Roof Cathedral
Cathedral Ceilings
Wood Framed Ceiling
2x12 @ 16 in. O.C.
R 38
0.030
Roofing: Light Roof (Asphalt Shingle)
Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofAdditiom Floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
4 @ -_=
R 38
0.025
Over Floor Joists: R-28.9 insul.
�'-diing Department
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition)
Calculation Description: Title 24 Analysis
Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 10 of 13
SLAB FLOORS
01
02
03
04
05
Inside Finish: Gypsum Board
07
08
09
Name
Zone
Area (ft2)
Cavity/Frame: R -15/2x4
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Exterior Finish: Wood
R-15 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 15
0.089
Siding/sheathing/decking
Floor Surface: Carpeted
Floors Over
Floor Deck: Wood Siding/sheathing/decking
R-19 Floor Crawlspace
Crawlspace
Wood Framed Floor
2x6 @ 16 in. O.C.
R 19
0.049
Cavity/Frame: R -19/2x6
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Existing Floor
2190
170
None
1
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Altered
No
WATER HEATERS
01
02
04
01
02 03 04
05
06
07
08
Name
Tank Volume
Heater Element Type Tank Type (gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas Small Instantaneous 0.2
0.96 EF
152000-Btu/hr _
0
0
WATER HEATING - HERS VERIFICATION
01
02
04
05
06
07
Name
Pipe Insulation
W_ FRTT
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 11 of 13
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Zonally Controlled
Multi -speed
Compressor
Heating System
Cooling System
NoCooling - No cooling equipment
N/A N/A
No
No
N/A
Verified Existing
HERS
Name
Type
Distribution
Fan
Floor Area
Location
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Furnace1
Other Heating and
Heating
Yes
Cooling
NO
Air Distribution
HVAC Fan
3053.4
Existing
No
Cooling System
Component 1
Component 1
Sealed and tested
System 1
1
Attic
None
Existing + New
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Name
System TYpe
Efficiency
EER SEER
Zonally Controlled
Multi -speed
Compressor
HERS Verification
Cooling Component 1
NoCooling - No cooling equipment
N/A N/A
No
No
N/A
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
U W-
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Air Distribution
Ducts located in attic
Sealed and tested
6.0
Attic
Attic
None
Existing + New
No
System
System 1
1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03 04
05 06
Name
Duct Leakage
Verification
Duct Leakage
%) Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
Required
U W-
WEl-W-ding Department
J
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
V e y- d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Ding_10206_Lockwood_Main.xml
CF1 R -PRF -01
Page 12 of 13
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
CUP�RT-NO -
--Bu--dlna Department
E EF R CODE -COMM A"NCS
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Ding's Main Residence (Existing+Addition) Calculation Date/Time: 18:31, Sat, Apr 09, 2016 Page 13 of 13
Calculation Description: Title 24 Analysis
Input File Name: Ding_10206_Lockwood_Main.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Mark Chu�"�'�
Company:
Signature Date:
Mark Chu & Associates
2016-04-19 16:43:30
Address:
CEA/HERS Certification Identification (If applicable):
1141 S. Stelling Rd.
City/State/Zip:
Phone:
Cupertino, CA 95014
408-255-4804
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Leo Li
Company:
Date Signed:
LEL Design
2016-04-19 17:05:12
Address:
License:
21701 Stevens Creek Blvd. # 32
NA
City/State/Zip:
Phone:
Cupertino, CA 95015
408-657-9928
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure t f this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
--Bu--dlna Department
EFR CODE -COMM A`
Registration Number: 216-A0054873B-000000000-0000 Registration ate Time: 2016-04-19 17:05:12 HERS Provider: CaICERTS inc.
Ea e ` - d
CA Building Energy Efficiency Standards - 2013 Residential Compliance Repor ersion `CF11 C3 u 2016 744 Report Generated at: 2016-04-09 18:33:01
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(1):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF 1 R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8(g).
150.0
§ (q)
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system pir
er buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal di
4 incI ,1 i ssociated with a domestic hot water recirculation system
§ I50.00)2A:
regardless of the pipe diameter, pi
, g f
he lied ing source to s orage tank or between tanks, piping buried below grade, and
all hot water pipes from the heatin
i
according to the requirements of TABLE 120.3-
A.
§150.0(j)2B:
mustAll be installed in a waterproof and non -crushable casing or sleeve
that allowsdomestic
installation, remova ai buried l t °e cd�° Mrd insulation.
Da°tt,�P yy>f�,,,,'y>f'�
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3 -A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 18113 or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflo
g
ontir I itrcation and diagnostic testing, in accordance with
BEL,
Reference Residential Appendix
IIL114.
Pool and Spa Heating Systems and Equipment M
110.4(a):
Any pool p gsystem l� I W luf�a „y that complies with the Appliance Efficiency
��� � � ging
tel
)II. �'°: I t the the heater the thermostat
Re Regulations; the
§
an on-off switch mounted out�te of eater n an loisi shut off without adjusting
setting; a permanent weathe root)" 11th d'.� � �
g p rp r m�� i i Q !&i��i g and shall not use electric resistance heating.
1
V)atEE"
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of §150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§ I50.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§I50.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§I50.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of §130.5; and all other requirements in §150.0(k)2.
§ I50.0(k)2L•
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential build or lighting ermanentl mounted to a residential building or other buildings on the
same lot shall be high efficacy, or i eff mei t he following requirements:
i. N the automatic actions of Items ii or iii below; and
,,the
ln' hII� S t eIr It l ,
�eY
150.0(k)9A:
§y
ii Coontrooll db a motionOs sensor overri yp� ss switc disables the motion sensor, or controlled by a
motion sensor having a temporary itch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor with ,"PWE�°BOO E ����'IlJAN
iii. Controlled by one of the following methods: I �.
Reweweu t5y-1,11. u.... �11!11
V.)a°lt"Pyaf yaf'�
2013 Low -Rise Residential Mandatory Measures Summary
I110 lItt l I1I1 IIS
BufldhiigDeparturent
FREVH.�.WED FDR CODE COWI[JANCE
Rev tew d By:4 I....C:°1.f
DatE< P 5/f!::,,'5f'�
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ I50.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§ I50.0(k)l 1:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § I10.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)l :
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l :
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and perman _ , d as "For Future Solar Electric".
I110 lItt l I1I1 IIS
BufldhiigDeparturent
FREVH.�.WED FDR CODE COWI[JANCE
Rev tew d By:4 I....C:°1.f
DatE< P 5/f!::,,'5f'�
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Ding's Main Residence (Existing+Addition)
4/19/2016
System Name
Floor Area
Furnace
3,053
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,113
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 120,000
26,898
2,012
848
40,161
Total Output (Btuh) 120,000
0
Output (Btuh/sqft) 39.3
1,220
2,230
Cooling System
0
0
Output per System 0
0
0 0
0
Total Output (Btuh) 0
0
2,012
0
Total Output (Tons) 0.0
1,2201
2,230
Total Output (Btuh/sqft) 0.0
Total Output (sgft/Ton) 0.0
1 29,338
44,622
Air System
CFM per System
2,035
HVAC EQUIPMENT SELECTION
Airflow cfm
2,035
Bryant 80T
0
0
120,000
Airflow (cfm/sqft)
0.67
Airflow (cfm/Ton)
0.0
Outside Air (%)
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
0
Aug 3 PM
120,000
Outside Air (cfm/sqft) 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
28 OF
69 OF 115 1'::'115 1'::r
10
a
Outside Air
4r-
0 cfm
Heating Coil Supply Fan
2,035 cfm
ROOM
69 °F
_.... ..................................................... 70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
88/t',8ol:::
79/62°F 55/54°F 55/54°F
r
ir
Outside AAr
0 cfm
Cooling Coil Supply Fan
56 / 54 OF
2,035 cfm
41.5
2
/'9 / 63 01::::::
��MCpartimen't
...........................................................................
r / 6 01::::::
UII�III
EnergyPro 6.7 by EnergySoft
User Number: 4970[3 EV If: 1 'I I iK' M0U; I "I
ID: 020116
Page 5 of 5