Loading...
B-2017-0856CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0856 10200 HILLCREST RD CUPERTINO, CA 95014 (326 16 089) OWNER BUILDER OWNER'S NAME: WEGNER GLENN AAND LINDA S TRUSTEE DATE ISSUED: 05/31/2017 OWNER'S PHONE: PHONE NO: LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class Lic. # Contractor OWNER BUILDER Date X BLDG —ELECT _ PLUMB MECH X RESIDENIAL COMMERCL&L, T I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: REPLACE WINDOW (11) - LIKE FOR LIKE TO MEET EGRESS I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. z. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $3100.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above "N Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize 326 16 089 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signature Date 5/31/2017 Issued by: Abby Ayende Date: 05/31/2017 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: 1. I, as owner of the property, or my employees with wages as their sole installed without fust obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: &/ ) contractors to construct the project (Sec.7044, Business & Professions Code). Date: 5/31/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER t. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Co Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shalll / be deemed revoked. Owner or authorized agent:...< APPLICANT CERTIFICATION Date: 5/31/2017 1 certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance correct. I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued (Sec. 3097, Civ C.) relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. �'�� Licensed Signature.Date 5/31/2017 Professional CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(@gupertino.org ❑ NEW CONSTRUCTION ❑ ADDITION ALTERATION / TI ❑ REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS 10100 ` G Y Q s r - OWNER # 7 �r/� /, OWNER NAME ] ( l _ iQ�L�y PHONEL}OdY� ZJ^7' EMAIVLR_-CYi7C)t{' o, e q-ePf'l144.4 STREET ADDRESS f O _ n , (� (`� (C V PV v I CITY, STATE, IZIP (f- nI� �(k ! � CJ3.. FAX CONTACT NAME lG o;, i /�% y��G PHONE l(.1C1 ~ZS *C��zO E-MAJL iU CK/l/1 ���IYfln 1(H�l � r STREET ADDRESS � 6) 2 c)© tel t/'I /C �P s ` %� /J CITY, STATE, ZIP " ! �S0/ FAX ( V l l (` Cd C(.i Ql� i�( A tI C� ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME ISG j I SUC j� ` LICENSE NUMBER 7 LICENSE TYPE BUS. LIC # COMPANY NAME j� l ��J/ _ y(� 1 1 E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECTIENGINEER N E LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK / ) � c►� 1 c�i�-� �7i�. I k c.Gl.�n I EXISTING USE PROPOSED USE CONSTR. TYPE I # STORIES USE TYPE OCC. SQ.FT. VALUATION (S) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH []ATTACH # DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY [IYES BEING ADDED? ❑NO ADDITION? []NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES REC D Y: T,QT�UATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHL❑ ER HOME? NOc4l� -�`JfJJ�� By my signature below, I certify to each of the following: I am the property owner or authorized agent to Ict on the p operty owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to b in c )n�stru^ction. IJauthhorize representatives of Cupertino to enter the above-identif d property for inspection purposes. Signature of Applicant/Agent: k!�' ✓ �/ '�`'.. Date: .r i SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE . ROUTING SLTP _ New SFD or Multifamily dwellings: Apply for demolition permit for❑ , ov> R-raE co[TNCER ❑ ' Buu DING rLA'5'REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ ExPRRss ❑ �PLANNING PLAN REVIEW „ _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD'_ ❑ PUBLIC woitj& ' form if any Hazardous Materials are being used as part of this project. ❑ LARGE ' ❑ FIILE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ ` sAIvITARYSEWERDIsnUCT; '. submittal of Building Permit application. ❑ " F1'TMONMENTAL HEALTH B1dgApp_2011.doc revised 06/21/11 CUPERTINO OWNER -BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - building@cuoertino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS IC ve,�1T2 G 0 'l APN ,/ UI BCP1�gf OWNER NAMEGOWNER ADDRESS/GZ�V+���� -e�� tp t q c,� (e�►� DESCRIPTION OF WORK: e G' z N'` �vamltw Ck6t114 f leS We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) 661. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner - Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Cwt,) 2.1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 6td 3. 1 understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 6W 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. Q,L,15. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 6tu)6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 7. 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. &11) 8. 1 understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForm 2010.doe revised 04114110 SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE 1 I COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION CU PE�RTINO 1.0300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 bulding(a.cupertino.ora ' PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon.Monoxide Alarms for compliance with 2016 CRC Section 8314, R315, 2016 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and! multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section 8314, R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms;be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) — (Smoke alarms'shall not be located within 3 feet of bathroom door) X X On every level of a dwelling unit including basements and habitable attics X X Within each sleeping room' X Carbon Monoxide alarms are not required in dwellings which do. not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall'be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery-operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential, Codes. The alarms specified below have been tested and are operational, as of the date signed below. ' Address: I d Zoo H d talc Permit No. W "2-0 1 (`G& 6 Specify Number of Alarms: 4 Smoke Alarms: # Carbon Monoxide Detectors: 1 have read and agree to comply with the terms and conditions of this statement Owner or Owner Agent's) Name: ............... Si nature ..................:............... v `' Date: ...5'/.�. Contractor Name: Signature...................................................................... Lic.#........................................ Date:................... Smoke and COform.doc revised 0111012017 WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION CUPERTt1.40 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 /' / (408) 777-3228 - FAX (408) 777-3333 • building(a cupertino.ora Zr p � Owner Name `)( e hli / ,, g"y l" Permit No. 01 a Address 0 �)r� k— c t1 l `►• t'� , C, r S� q, 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections.1101 A through 1.101.8 do not apply. Skip the rest of the form and sign bottom of form. �'No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the 'rest of the form and sign bottom of form. KNo Go to Question 3. 3. Is water service permanently disconnected for your building? El Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. LL -No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code -Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. k -Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply, Check one of the three following statements and sign bottom of form.. Ple se check ONE of the following:. My property is a single family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbinIg fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or irnprovemenfs). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall.require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January'l, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a c077277xe7lcial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- _ conserving plumbing fixtures throughout the building (regardless of whether property undergoes, alterations or improvements). I, as the owner or owner's agent of this property, certif}7 under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101,1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requiserrlents, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following Dage. Glr i Owner or Owner Agent's Signature: Date: completing and signing this Certificate, please return it to the Building Division in order to final vour building nermit SB4072015.doc rel ised 01,9 /17 1. ; If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4071015.doc remised 08/16115 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixture/ (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 . 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3- 2013 CALGreen Div. 5.3 _ Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the, performance criteria of gallons'per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.)., For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled, by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets - Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets. 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi, Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen , per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where'faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. ; If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4071015.doc remised 08/16115