Loading...
B-2017-0852CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0852 976 NOVEMBER DR CUPERTINO, CA 95014-4121 (362 13 025) PROVOLTZ INC CAMPBELL, CA 95008 OWNER'S NAME: AU EDMUND CHI -YIN AND AMY MAY TRUSTEE DATE ISSUED: 06/01/2017 OWNER'S PHONE: 408-582-4364 PHONE NO: (408) 796-4450 LICENSED ..NSA .ONT A .TOR'S DECLARATION BUILDING PERMIT INFO: License Classfi Lic. #919207 Contractor PROVOLTZ INC Date 11/30/2018 J BLDG —ELECT —PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N) 15 -PANEL ROOF MOUNTED PV SYSTEM (4.5 KV) I hereby affirm under penalty of perjury one of the following two declarations: t. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. z I have and will maintain Worker's Compensation Insurance, as provided for by __rA1 Section 3700 of the Labor Code, for the performance of the work for which this //(( Sq. Ft Floor Area: Valuation: $17000.00 �� permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 362 13 025 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per a '' unicipa Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Signature ` - Date 8/1/2017 Issued by: Abby Ayende OWNER -BU wyezi� Date: 06/01/2017 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofmg material being installed. If a roof is t. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. 1, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 6/112017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER t. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 1 I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. 1 certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code 12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sec ' S , and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or authorized agen . APPLICANT CERTIFICATION Date: 6/1/2017 1 certify that I have read this application and state that the above information is CON TRUCT19"YN/G. AG correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a cons ctio ency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 6/1/2017 Professional CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildina(cicupertino.org O&5z AE PROJECT ADDRESS APN # OWNER NAME a Ad/1A h PHONE �/� (� % �/ l D L (�J E-MAIL STREET ADDRESS /7i / e Vim. r jI ,r CITY, STATE, ZIP /" t ^ J 1 S o / L,-/ V^7 FAX CONTACT NAME ,.t a �µ \ PHONE / / (7 I ? EMAILPyO Vu J � t . C STREET ADDRESSC� J ° J AV, t' CITY, STATE, ZI ❑ ovoN'ER ❑ OWNER -BUILDER `_-AGENT ❑ CONTRACTOR CONTRACTORAGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER 7- [ LICENSE TYPE,/_ & Il /' BUS. LIC #� COMPANY NAME / rvo VII 7 f b1 E-MAIL / - / (b Vo l Z , Cci."� FAX STREET ADDRESSrj I� l/ t .1Lr CITY, STATE, ZIP /� /I �J� ` / PHONE ARCHITECT,'ENGINEER NAME LICENSE NUMBER BUS. LIC.4 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD Or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN NAILDLAND URBAN INTERFACE AREA ❑ Yes O IVO PROJECT IN FLOOD ZONE ❑ Yes ❑ NO ❑ SOLAR. PANELS 1 ❑ ELECTRIC VEHICLE CHARGING STATION SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PAA'EL.S: NUMBER OF PANF.LS/IJNITS: % / KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: 1 N DESCRIPTIOOF WORK L4 ✓ k. ✓ w1 �. RECEIVED BY: By my signature below, I certify to each of the folio the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provi is correct. I ave read the Description of Rork and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to b nstruction. I au rize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: SUppLE L INFORMATION REQUIRED OFFICE USE ONLY W ❑ r OVER-THE-COUNTER ,a F ❑ EXPRESS U =� ❑ STANDARD +U ❑ LARGE a ❑ MAJOR PVApp_2011.doc revised 03/16/11 >�1 CUPERTINO SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 950143255 (408) 777-3228 • FAX (408) 777-3333 • t_, dir rcupertlno ora PERMIT CANNOT BE FINALED UN FIL TIIIS CERTIFICATE HAS BEEN COMPLETED, SIGNED. AND RETURNED TO THE BUILDING DIyTSIO-N PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314, R315,2016 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314, R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM I CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) — (Smoke alarms shallnot be located within 3 feet of bathroom door X X On every level of a dwelling unit including basements and habitable attics X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below. Address: 97 /l/oun„ bQv D�. Ckppl-ti,1.o, CA 9.161<6 Permit Specify Number of Alarms: # Smoke Alarms: I 1 ) I # Carbon Monoxide Detectors: I have read and aqree to comply with the terms and conditions of this statement Ece Owner (or Owner Agent's) Name: �1�1V11A h/r.D /..�... f+� Signature ........................ ..... ............................................................................Date: ��.. Co tractor Name: 1 7..Ic j Wo .19 ....... Date: Si nature ... . # ... .(.:.111.19? 7 Smoke and COform.doc revised 0111012017 CUPERTINO WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(c cupertino.org Owner Name ry P\ t& ,Permit N o. Address 7 6 AlovewAz. '-. LA i f 4 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections. 1101.1 through 1.101.8 do not apply. Skip the rest of the form and signbottom of form. 5/No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. E�No Go to Question 3. 3. Is water service permanently disconnected for your building? 11 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. `E f No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 5� Yes My real property is.buiit and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statement's and sign bottom of form.. 5.i Please check'ONE of the following:. IZ Mypropei-tyislasingle fancily residential realproperty. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑' My property is a nnultifarnily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixiLs to be replaced with water -conserving plumbing fixtures. On or before January l; 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ Myproperty is;;a c0772771_ercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant . plumbing fixtures to be replaced with water-conseiving plumbing fixtures. On or before January 1, 2019, all non-compliant- plumbing fixtures shall be replaced with water-_ conserving plumbing fixtures throughout -the building (regardless of whether properly undergoes alterations or improvements). 1, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above i�dth water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the folloi�,i.ng' age. Owner or Owner Agent's Signature: Date: V2 2-6 Upon completing and signing this Certificate, pleast" e rn it to the Building Division in order to final your building pernit. SB4072015.doc revised 01/05117 4- 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072015.doc revised 08/26/15 Non -Compliant Water -Conserving Plumbing Fixture Plumbi ng Fixturel (Fixture Complying with Current Code Applicable to New Construction) Maximum (Nater Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4' /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considereda showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi,.or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 .gallons per minute @ 60 Kitchen per minute 60 psi - @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means. may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072015.doc revised 08/26/15 Quick reference info - 4.83 kW solar PV system using (14) SunPower SPR -X21 -345 -C -AC panels on Invisimount racking System is grid tied, no UPS, no batteries Roof mounted system adding 2.94 Ibs/sgft - Roof is composed of Metal Tile with 2 x 6" rafters 24" O.C. Roof is (1) story with 5/12 pitch - PV module fire certification: Class A (detail on pg- 4) - Racking fire certification: Class A (detail on pg. 7) worker's Compensaslon carrier Crmpir munion Fund Cr,ntacl Ph: 187714M.4d 4i FIMCi 09030822-12 AeoeWS 12-1-2015 General Liability Insurance Carrier VJlnrha5ler Supply Lines Ins Broker Contact F'h: (800) 228-3380 Pnlicy # G2439q.1A9001 Renrsws 4•'2fv'2015 2PrCq1) 6 itZ Edmund Au 976 November Dr Cupertino, CA 95014 Vicinity map W Photovoltaic installation project Project description: - 4.83 kW roof mounted solar ACPV system valued at $16,000 Sheet index 1 Cover sheet 2 Site layout COMMUNITY DEVELOPMENT DEPARTM ENT 3 Single line dre Ire BUILDING DIVISION —CUPERTINO 4 Solar module at APPROVED 5 System groupT s set of plans and specifications MUST be kept at th job 6 Roof Attachmeniediatiag construction. It is unlawful to make any chan s or 7 Racking enginealteration, $aonasame, or to deviate therefrom, without ap Cii from the Building Official. oval The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of e ny provision of any City Ordinance or State Law. BY Abby A ende DATE 06/01/17 PERMIT No B-2017-0852 Applicable Code: 2016 California Building Standards Code 2016 California Electrical Code (2014 NEC) 2016 California Residential Code Cupertino Municipal Code Prepared by Mich aeIFerreira -SrDesigner- Mobile -14081863-2770 Site Address 976 November Dr Cupertino, CA95014 Provoltz Inc Lic # 919207 Class C-46 Customer Name Edmund Au 583 Division St Suite B S ���� Campbell, CA 95008 nn/27/17CUP ercontact 1.408.582.4364 edmundauhome@yahoo.com (408) 796-4450 TS, , .. REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 Title page 1 NOTES 1. MAX HORIZONTAL SPAN BETWEEN ATTACHMENT POINTS = 72" 2. MAX CANTILEVER OF RAIL PAST LAST ATTACHMENT POINT = 24" 3. RAILS TO BE MOUNTED SO RAILS ARE NO LESS THAN 6" AND NO MORE THAN 16" FROM TOP AND BOTTOM OF MODULE. 4. PANELS TO FOLLOW 2016 CALIFORNIA RESIDENTIAL CODE GUIDELINES FOR FIRE SETBACKS. Attachment points in 2 x 6 Rafters • Invisimount Racking Prepared by Michael Ferreira - Sr Designer 408) 0tRTI ProVoltz Inc Building Depa 583 Division St Suite B Drawn o /17 Campbell, CA 95008 Scale: REVIED FOR CODE COM (408) 796-4450 Reviewed By: Abby Ayen Date: We Address omer Name (E) 200 A MSP and Meter (point of interconnection and rapid shutdown) Fire Setback => 36" (14) SPR -X21 -345 -C -AC Modules 976 November Dr Cupertino, CA95014 Edmund Au LCAao-tomer contact 1.408.582.4364 edmund_au_home@yahoo.com Scale Layout 2 (4) 10 AWG THWN-2, (2) 10 AWG THWN-2 EGC, (1) 8 AWG THWN-2 in 3/4" EMT \ NEMA 4, Outdoor Wet - location J -box in (2) 10/3 Romex, (1) 8 AWG bare copper GEC through 8 (14) SunPower SPR -X21 -345 -C -AC modules in (2) string of (7) For Each AC Module: 240 VAC 1.33 A Max Output 1. A DC DISCONNECT IS NOT APPLICAPLE, AS ALL DC CONDUCTORS ARE FACTORY -WIRED TO EACH MICRO -INVERTER. 2. WIRE AND SIZES AREAS INDICATED OR LARGER. 3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY EQUIPMENT GROUNDING CONDUCTOR. 4. THE EQUIPMENT GROUNDING CONDUCTOR SHALL BE #10 AWG OR LARGER AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. 5. THE AC DISCONNECTING MEANS WILL BE LABELED WITH SIGNAGE SAYING: OT main - r service panel (E) 200 A Main 6. THE ELECTRIC SERVICE PANEL WILL BE CLEARLY LABELED Service Panel fed WARNING: THIS PANEL IS ALSO POWERED BY A by 200 A main SOLAR PHOTOVOLTAIC SYSTEM (2) 2 -pole 15 A breaker breaker located opposite of feeders SHUTDOWNRAPID AC wire size calculations: Total Source Calculation: cifications (SunPower SPR421-345-C-AC) Output @ 240 V (min/nom/max) 211/240/264 V Branch 1 (7 panels) Total Allowable Source = 120% bulbar rating Operating Frequency (min/nom/max) 59.3/60.0/60.5 Hz Continuous Current = Imax x number of panels in string x 1.25 = 1.33 Ax 7 x 1.25 = 11.6A Output Power Factor (min) 0.99 Max Total Sources Allowed = Bulbar x 120% (705.12(D)(2) Derate Ampacity = 90 deg Rating of Conductor (10 AWG) (T -310.15(B)(16) = 200 x 1.2 = 240A AC Max Cont Output Current @ 240 V 1.33 A x 122 deg Temp Correction Factor (T -310.15(13)(2)(a) = 40 A x .82 = 32.8 A Utility Source = 200 A AC Max Cont Output Power 320 W PV source = 30 A So that, Derate Ampacity > Continuous Current = 32.8 A> 11.6 A>> OK Total Source = 200 + 30 = 230 A Max Units Per Branch Circuit @ 240 V 12 And, Derate Ampacity > Overcurrent Protection Device Rating = 32.8 A> 15 A>> OK If total Source < Max Sources Allowed = 230 A < 240 A» OK Certifications UL 1741, including compliance with applicable requirements of IEEE 1547 and IEEE 1547.1 Fire rating Type 2, Class A Compliance Alternating Current (AC) Module designation enables installation in accordance with NEC 690.6 by kchael Ferreira-SrDesigner- Mobile -(406)863-2770 Site Address 976 November Dr Cupertino, CA95014 Single Line hdkffPrepared I Pro Voltz Inc 583 Division St Suite B Customer Name Edmund Au 3 3/27/ 1C U P E Campbell, CA 95008 NTS n TIMMer contact 1.408.582.4364 edmund_au_home@yahoo.com (408)796-4450 REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 Iptilvn-Drwn Pf.1Ua 1TAT-S . S27 rradulu acrl�clic arr+cil�ax� k:nT3Tlpficd marc rdilhllt}� :S-yn:r :ia nW-1 Panel a IN 9tuduu VI—tf Vii rnA7P VRh P T.7r RW Sa s{.izcfer roof. n34 &-G lr rtu Cp'rrix prri—rrc nF-chrnock -ipF; r 1)Lep I -vi r" [7jnnnR Caep'tx ra]7: 3. P -n r:NdFI8 4Tol ;�ocmc S-rnplgy & sj.^eed]nEaltmn Fgmorrrh�r x�i nnoairwwbar Ral-, duLbaJod-g AC s.—b s rlag fr �; it, cgsle erd arL�tr Fib 0C..T; - - nr FT]PS -DTp=- oiCom.Attt Sgstiem dEk rnru� xRh SEnPoIR=_r'lrush9nmC end IFe �r FSwe-Nmtorr.� iy rn Sipe u: v�ry.xi i elie:"ly au xx}rliu T 1" 2PrCQ1)h1hWr ID"Af.A AL d-rLulait'LR•shr iei RIM - 1-11 rJaxon�4en 111 3oR�i 'lanira ro rnr:IfYiard 3i^_W 335 Y! rgi u,riiaui .ri}n c,: biessw ih uit �S.rrTd�r= •i/Ar Jori rrcn Qm n'f.ar.rco-z aE. prr.l CFF---? AEA 211A% F e Cu iJ lrt= r .Cw FLLvw�; 8]OLPC har �.,. oa., -= or.rsrdnd [51� rauS rrJr� Er -7.1 -- rirpit=r' dJe.e�iinmJnJm S-lYr �6'I A L. 1-. k5' pen-Wr3 44-. Fr[omn,rtc ,�u: lil mnl 1luiluk SE...Ii� Opr mae ry-qern and InsEaliedDn Erderci SurAw.cf+iC Fiodias.'hr'iil ixlum ] r]�pry�,wg]md MrP-7%w rnr-,OIm-ter 711P1Lp d'l'19hIhC1li?f6T➢rV6p, iTgl eREc,�saixh i�eln2e.erx: n::s `..�±. 7C-'frCi� e.aruessi.nL 0.-�gr3d lordrrlM So-- us MF. Sinl�nc- IT.eihksrA"a,d tlx rr r.ar ld�rL�m?;F�.+n 4rA—X-VErLil-6ii-gid IrEE�lln hes�nca� sfsen F,, 3rdlralMw JNglti i� ]�ler^R�i srw-e.Jllttucarnnv2fx 3•r br-t=ornbin�F:wrr ]nc Prodrn W -1y. -hfpLt wR01re3n.Ycm .Yx 7,:deil'Me 4' ]r[oi[ b 203`, Mmc&M:LL 7r[ 'icr_i Feuu r ri ] 043 hC}la. C-.-&L4f Cu..1¢2i0V ,33h 4f ilm frvrinvcr rh1r.1 f—&XAV SdA .X2AC CEC Cm,csvr EF -0, 160V lnc un✓Is is AkA K-arwh[_rnl 10 140V pn-: r7u U-Fe:LLrtE UC-kq AMY s4 LYG wlr: •_ 1pnr,r,3T•nM1 dOu L'n+Sf4s3t_ 8's: inrir"'I YL¢Anbnffmc 1SF45VC 5NC•n,r 1RITC IIl 35. LILTJ 'i 194 �'IY'rIM111111 �..... it! ;id00 lgl_Aar.- r.T- P -i- t -h L2+ rrls ,�y�y��1dLe}wF4,c 9.Y5r��1�p�K2YM P,R✓t y1�Ad�Cf-1�5 ^L6 Vaiaf{y YYrrlarrYi�r,! �1� Ytli M1�' nl4' sunpower.com ry rnrr�.mna.o>Rrrnw,w�a.>_,.v Prepared by Michael Ferreira - Sr Designer - Mobile - (408) 863-2770 I Ws-- 25y- h.- F. I ,I{I u0ri n{s ei nils �f E[E tx7• z IEF,E ISb'.1 rC�ra]i_te Trrr2 FYie rb.e[ 11. rrz� �-.r �Y newl.rtvxL rnl5kwn(" rnuNwre" ani-Lra htl,+r_ rser ricfav srd baeer el Cunbnnr raedc F.rrr 3 s 3�' ri.n nsegj C- -W- nrmW-n nrmrlrnt xrh urL- Mann 'Mu 7t■ 000 I S It Site Address 976 November Dr Cupertino, CA95014 Provoltz Inc Customer Name Edmund Au Ca Division St Suite 8 INTS C U P E T� � n - Campbell, CA 95008 le: NTS 'CthTol'�er contact 1.408.582.4364 (408) 796-4450 REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 edmund_au_home@yahoo.com Module Specs 4 1.7 Grounding Overview (from installation manual) Warning! Ensure that you fully understand the grounding aspects in this section before proceeding • The AC dedicated branch circuit wiring from the readily accessible disconnect to the array must include an equipment grounding conductor (EGC) in the same raceway or cable as the AC circuit conductors. This EGC must be connected to the green conductor of the transition cable, which is part of the AC module cable system. • If a module is removed from a circuit, SunPower strongly recommends that you install a temporary EGC to bridge the gap by inserting an AC extension cable or other means, in order to maintain effective ground continuity to subsequent modules. • Because the modules are connected in a "daisy chain" fashion, disconnecting one module from the circuit using the AC cable removes voltage and ground from the other downstream modules in the circuit. Extreme care should be taken to ensure that no other energized sources are adjacent to these ungrounded modules, otherwise auxiliary grounding methods must be applied. • Because the DC power is internal to the module, a grounding electrode conductor (GEC) for the module or array is not required. The existing AC GEC at the utility service serves as the NEC -required GEC for the structure. • The AC cable grounding path has been tested by a NRTL, and its electrical continuity from the AC cable ground pin to the module frame has been certified. • The AC module interconnecting cable system provides an internal EGC for grounding the AC modules. It is the installer's responsibility to ground any metallic mounting structure according to local code. Installers must ensure that whichever mounting system they choose is then grounded according to the instructions of that mounting system. Some mounting systems can be bonded to the ACPV modules with listed devices. Consult the module's included safety instructions for details. • The AC modules or array do not require a GEC, and the neutral conductor within the AC module is isolated from ground. The AC module must be connected to a dedicated AC branch circuit with the neutral conductor referenced at the building service entrance. • The AC interconnecting cable system attached to each module's microinverter is fully insulated and includes an internal EGC. The grounding pin is longer than the others in the plug. The ground path from the transition cable to the module frame is as follows: • The transition cable's green conductor is connected to the EGC from the utility dedicated branch circuit. • All plugs have ground pins that are longer than the circuit pins. This extra length ensures that the ground is the first to make contact when connecting modules and the last to break contact when disconnecting modules. • The AC ground wire inside the microinverter terminates on the microinverter chassis with a bolted connection, and is environmentally sealed. UL and NRTL certified equipment bond chain ueou_� rwacLL� Rails are bonded to the module frames through theme Avmid clips. • The microinverter chassis is bonded to the module frame with stainless steel hardware to provide ground continuity to the module frame. Prepared by Michael Ferreira - sr Designer -Mobile -(408) 863-2770 :Prco I Pro Voltz Inc 583 Division St Suite B 3/27/1 CU P E Campbell, CA 95008le. NTS (408) 796-4450 r Rails are bonded to each Site Address 976 November Dr Cupertino, CA95014 Name Edmund Au contact 1.408.582.4364 edmund_au_home@yahoo.com REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 Inverter Specs 5 IStone coated steel roofing bracket specs. 00 203.75 UNLESS OTHERWISE SPECIFIED ❑EauR®®GES DIMENSIONS ARE IN MILUMEIERS suuaeLE FGR Hu"uo Ano sALT EHVIDRnx�auls SURFACE FINISH GaN—d TOLERANCES: +/- 25mm Ll Ll 60 64 79 DONOTSCALF—ING REVISION 1.1 _ms_ .f, Pluto. a. synee� Soitl oz eocbxfiicb iclWesR� P froM1on of store moles steel 9 olenoL 1-PY84bmclret HD -0 or I80 -DSO]. 1-M 318"x I" 16}pi collage boe. 1- 33318-zemfetl Mtge nut ENGINEERING SPECIFICATIONS — PV Bracket Solutions Moxwe�Il pn gllgcireglcrd alternate, lead: WA lbs. rtluinum gbwgbk bad: 52.31bs. safely facia=lb Rmfatlachm.m 3/ax35'-CIopbolt(mgzie0(Ifi"predlietlhdeontlrtln2-perthalon] Part Number: Eupaedomrchment 3/8x1-GRAOESSS eungge bott3l-M ff lbs_(MN(FAA%} 100-0`48 Rates paH oN zherglh 3/ax 1' GRADE s SS curage bott31-M ff Ibc. IMNjMA%} 1 00-050 �A 10rnygcdd relied."o Non penetrating bracket low carbon steel for Stone Coated steel Roof 1 sea SH -1 OF 1 Invisimount integrated grounding details: and mill Note: The I Note: The _ y -'; splice screws ,r module mid Profile�•-"� serve as rail to .•rte Lir .--'Its+ clamps P . �. - ' :?f•r'••' rail bonding serve as y module to rail :.•'-' ..f.- I bonding — .• . - Irr1x*� Max Horizontal Span = 7'- 6" Prepared by Michael Ferreira - Sr Designer -Mobile -1408'863-2770 Site Address 976 November Dr Cupertino, CA15014 Roof Attachments Pro Voltz Inc TCustomer Name Edmund Au 583 Division St Suite B CUPS 1 nn L Prcq) Campbell, CA 95008 �� ° 7�iitSmer contact 1.408.582.4364 edmund_au_home@yahoo.co U (408) 796-4450 BuildingDepartment REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 Torque specifications L -foot to mil 20 in lbs Mid clamps 5 in Ibs End clamps sin be E C T O R Splice screws 40 in lbs E n G I rT E E R a Structural & attachment details 651 W. Galena Park Blvd. T (801) 990-1775 Square footage per module (41.4" x 61 Sj 17.7 sqh Draper, UT 84020 F (801) 990-1776 Total system square footage 187.6 sqh STRUCTURAL ONLY Total system weight (2.94 lbs sq/tt including mounting system) 551.544 lbs �gpFI Minimum quantity of attachments (each with 1 - 5/16" x 4 1/2° 20 lag bolt with 21/2" minimum penetration) 5S Dead load attachment (total weight +attachments) 27.6 lbs ♦� per 7 Pull out stmgth per attachment 205 lbs Total pull out strength (205 x 20) 4100 Q. CIV11 ~ qTE OF Design wind load (-15.2 lbs/sq/ftuplift X 187.6 sgHt) Corrected pull out strength (pull out strength minus wind -540.3 lbs CA<.VF load) 3559.7 the 05/23/2017 safety factor 6.5 times solar panel mounting rail structural attachment roofing material rafter SunPower SPR- See detail bottom left See detail at top left Metal Tilr 2 X 6" 24" O.C. X21 -345 -C -AC i Max Horizontal Span = 7'- 6" Prepared by Michael Ferreira - Sr Designer -Mobile -1408'863-2770 Site Address 976 November Dr Cupertino, CA15014 Roof Attachments Pro Voltz Inc TCustomer Name Edmund Au 583 Division St Suite B CUPS 1 nn L Prcq) Campbell, CA 95008 �� ° 7�iitSmer contact 1.408.582.4364 edmund_au_home@yahoo.co U (408) 796-4450 BuildingDepartment REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 Module*/ Mid Clamp and Rall Module* / End Clamp and Rall Mitl Clamp Entl Clamp Rail&Rail Sorce End Cap d D nvislvount Operating Conditions Invisivount Component Details warrannes 2s-earproduaw., 1, Roof Atta C hment Hardware Supporteo 1"vislvount 51ear f—h warranty Investigatetl UL 2703 L,v,d Certfiica[ions Class Aflre rating when distnce between a oof surtace and bolt rapt 3unPower Mechanical module frame Is <35" nvislvount Operating Conditions Mpauleframe mat lz comceable umtne lnv�z�Mounc zyzrem required for nardwarelnrerocerab�llry. IRngntzl Re„ervea. s WERha+e sUNROWER Ingo. and lNVI51MOUM aretrademarkz or reglsterea perryafineo- resPearae owners. unpowercom p Pcauonzmcludedin MiztlausM1eerare Ix roc ge irnomnonre. Document #509506 RevB Prepared by Michael Ferreira - Sr Designer- Mobile - (408) 863-2770 ProVoltz Inc ;pr 583 Division St Suite B U P E Campbell, CA 95008 3/27/ (408) 796-4450 nNTTSii, OIMS.E466981 - Mounting Systems, Mounting D.A..., Clamping D..., and Ground Lugs for Use with Photovoltaic Modula. and Panel. 9/15/15, 3:05 PM uL ONLINE CERTIFICATIONS DIRECTORY Q I M S. E466981 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels SUNPOWER CORP 77 RIO ROBLES SAN JOSE, CA 95134 USA warrannes 2s-earproduaw., 1, Roof Atta C hment Hardware Supporteo 1"vislvount 51ear f—h warranty Investigatetl UL 2703 L,v,d Certfiica[ions Class Aflre rating when distnce between a oof surtace and bolt rapt 3unPower Mechanical module frame Is <35" Mpauleframe mat lz comceable umtne lnv�z�Mounc zyzrem required for nardwarelnrerocerab�llry. IRngntzl Re„ervea. s WERha+e sUNROWER Ingo. and lNVI51MOUM aretrademarkz or reglsterea perryafineo- resPearae owners. unpowercom p Pcauonzmcludedin MiztlausM1eerare Ix roc ge irnomnonre. Document #509506 RevB Prepared by Michael Ferreira - Sr Designer- Mobile - (408) 863-2770 ProVoltz Inc ;pr 583 Division St Suite B U P E Campbell, CA 95008 3/27/ (408) 796-4450 nNTTSii, OIMS.E466981 - Mounting Systems, Mounting D.A..., Clamping D..., and Ground Lugs for Use with Photovoltaic Modula. and Panel. 9/15/15, 3:05 PM uL ONLINE CERTIFICATIONS DIRECTORY Q I M S. E466981 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels SUNPOWER CORP 77 RIO ROBLES SAN JOSE, CA 95134 USA Investigatetl Roof Atta C hment Hardware Supporteo 1"vislvount Investigatetl for System Design Tool Tested in for Mechanical Classification Combination ® Bonding Roof �t1c�Fr-tenL a �d.ta� N/avant es (A, B or C) With Photovoltaic mounting system Mpauleframe mat lz comceable umtne lnv�z�Mounc zyzrem required for nardwarelnrerocerab�llry. IRngntzl Re„ervea. s WERha+e sUNROWER Ingo. and lNVI51MOUM aretrademarkz or reglsterea perryafineo- resPearae owners. unpowercom p Pcauonzmcludedin MiztlausM1eerare Ix roc ge irnomnonre. Document #509506 RevB Prepared by Michael Ferreira - Sr Designer- Mobile - (408) 863-2770 ProVoltz Inc ;pr 583 Division St Suite B U P E Campbell, CA 95008 3/27/ (408) 796-4450 nNTTSii, OIMS.E466981 - Mounting Systems, Mounting D.A..., Clamping D..., and Ground Lugs for Use with Photovoltaic Modula. and Panel. 9/15/15, 3:05 PM uL ONLINE CERTIFICATIONS DIRECTORY Q I M S. E466981 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels SUNPOWER CORP 77 RIO ROBLES SAN JOSE, CA 95134 USA Last Updated on 2015-07-29 ©2015 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Fallow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions:1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice In the following format: V 2015 UL LLC". http://database.ul.com/ogl-bin/XYV/template/LISEXT/1 FRAME/show...]3741824&version=verslonless&parent_Id=108153454]&sequence=lAC Pagel oft Site Address 976 November Dr Cupertino, CA95014 o er Name Edmund Au Racking Engineering us o0er contact 1.408.582.4364 edmund_au_home@yahoo.com / REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 Investigatetl Investigatetl for System Fire Tested in for Mechanical Classification Combination Cat. No. Bonding Loading (A, B or C) With Photovoltaic mounting system InvisiMount - consisting of Y Y A UL Listed PV Modules: the following components: Sun power Corp: Models Si where L_ Foot, Rall, Rall Splice, Yy represents numbers 18, 19, 20 or 21, and Mid Clamp, Ground Lug ### represents any number from 365 to 310 Assembly, End Clamp. and 274 to 233; SPR-EYY-###, where Y1' represents numbers 18, 19, 20 or 21, and ### represents any number from 345 to 285 and 250 to 225. All models identified must have the Gen 5 frame and have a Type 2 module characterization. Y Y A NRTL Listed: SPR-XXXE/NE-WHT/BLK-U-YYYACPV and SPR-V- wW-XXX-Y-Z-G-AC, where "XXX" is the wattage of the panel and ranges from 250 to 225; and where "YYY" Indicates the Inverter voltage used in the module, and can be blank, 240 or 208/240. All models identified must have the Gen 5 frame and have a Type 2 module characterization. Last Updated on 2015-07-29 ©2015 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Fallow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions:1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice In the following format: V 2015 UL LLC". http://database.ul.com/ogl-bin/XYV/template/LISEXT/1 FRAME/show...]3741824&version=verslonless&parent_Id=108153454]&sequence=lAC Pagel oft Site Address 976 November Dr Cupertino, CA95014 o er Name Edmund Au Racking Engineering us o0er contact 1.408.582.4364 edmund_au_home@yahoo.com / REVIEWED FOR CODE COMPLIANCE Reviewed By: Abby Ayende Date: 06/01/17 CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20160121-E478330 E478330-20150916 2016 -JANUARY -21 Issued to: SUNPOWER CORP 77 RIO ROBLES SAN JOSE CA 95134-1859 This is to certify that AC MODULES representative samples of USL - AC modules, Models SPR -X22 -360 -C -AC, SPR-X21- 335-BLK-C-AC, SPR-X20-327-BLK-C-AC, SPR -X21 -345 -C- AC, SPR -X21 -335 -C -AC, SPR -X20 -327 -C -AC, SPR -E20- 327 -C -AC, SPR -E19 -320 -C -AC Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for safety: UL 1741 - Safety for Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources. Additional Information: See the UL Online Certifications Directory at www.u1.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow -Up Service. Look for the UL Certification Mark on the product. Bruce Mahrenholz, Director North American Certification Prog C U P E RTI N O UL LLC IIuu�11 ►'� [[]] Any information and documentation involving UL Mark servic n b aF of UC�LL' UL�orea�ya au cens contact a local UL Customer Service Representative at htt :llu . ations/ Page 1 of 1 REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende Date: 06/01/17 e of UL. For questions, please File E478330 Vol. 1 Sec. 1 Page 1 Issued: 2015-09-16 and Report Revised: 2016-01-21 DESCRIPTION PRODUCT COVERED: AC modules USL - AC modules, Models SPR -X22 -360 -C -AC, SPR-X21-335-BLK-C-AC, SPR-X20-327- BLK-C-AC, SPR -X21 -345 -C -AC, SPR -X21 -335 -C -AC, SPR -X20 -327 -C -AC, SPR -E20 -327- C -AC, SPR -E19 -320 -C -AC USL - (QHZS), Evaluated to the requirements of the Standard for Safety for Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources, UL 1741, Second Edition, dated January 28, 2010. GENERAL: The construction consists of a Listed (QIGU) or Recognized (QIGU2) Photovoltaic Module which are provided with permanently attached accessories and hardware. The added accessories and hardware include a Utility Interactive Inverter having an integrated connector ended whip for connection to a separately provided wiring harness, mounting hardware, and grounding hardware. The inverter/ converter is a Recognized component (QIKH2), and is provided with transformer isolation between input and output. The completed assembly is designed for use as a non-structural component of buildings only. Field wiring connections to the product are made via is provided separately from this Listed product, via having polarized connectors that accommodate a wiring acceptable for the application in accordance with the Code. CUPERTINO Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende Date: 06/01/17 a wiring harness which dedicated connectors system that is National Electrical CERTIFICATE OF COMPLIANCE Certificate Number 20161112-E479127 Report Reference E479127-20150916 Issue Date 2016 -NOVEMBER -12 Issued to: SUNPOWER CORP 77 RIO ROBLES SAN JOSE CA 95134-1859 This is to certify that COMPONENT - STATIC INVERTERS AND CONVERTERS representative samples of FOR USE IN INDEPENDENT POWER SYSTEMS; COMPONENT - PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT See Addendum Page Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: See Addendum Page Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow -Up Service. The UL Recognized Component Mark generally consists of the manufacturer's identification and catalog number, model number or other product designation as specified under "Marking" for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL's Component Recognition Program, UL's Recognized Component Mark: 911, may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under "Markings" for the individual recognitions. Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Certification Mark on the product. Brucenholz, Director North American Certification Prog CUPERTINO UL LLC IIuUJ,1 rij1 [[j� n l'� r� pp `` Any information and documentation involving UL Mark servic n has of OL�ZL�ULTorea� aauChtoniedlicensee of UL. For questions, please contact a local UL Customer Service Representative at htt ://u . tions/ Page 1 of 2 REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende Date: 06/01/17 CERTIFICATE OF COMPLIANCE Certificate Number 20161112-E479127 Report Reference E479127-20150916 Issue Date 2016 -NOVEMBER -12 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Permanently -Connected, Utility Interactive, Split Phase Micro -Inverter, Model MI-C-320-US208/240-XX Where "XX" is one of the allowed options in the nomenclature section below inverter is intended for DC input from a single photovoltaic module The inverter is provided with transformer isolation between input and output. The inverter is also evaluated as PV Rapid Shutdown equipment with Line 1 and Line 2 AC output conductors evaluated as the controlled conductors. Actuation is provided by opening the AC conductors by a breaker or other disconnect device UL 1741 Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources UL 1741 CRD for Photovoltaic Rapid Shutdown Equipment CSA 22.2 No. 107.1-1, General Use Power Supplies Brucenholz, Director North American Certification Prog CUPERTINO UL LLC IIu,1 rj [j p ` Any information and documentation involving UL Mark servic n b�ty i OL(ZL�l1L�orea�'a�uChtoniedlicensee of UL. For questions, please contact a local UL Customer Service Representative at htt ://u . ations/ Page 2 of 2 REVIEWED FOR CODE COMPLIANCE Reviewed By:Abby Ayende Date: 06/01/17