13010062CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10560 WUNDERLICH DR
CONTRACTOR: WONG'S GENERAL
PERMIT NO: 13010062
CONSTRUCTION
OWNER'S NAME: MANVI RAJENDRA AND SUMA
21150 SARATOGA HILL RD
DATE ISSUED: 02/25/2013
OWNER'S PHONE: 4084314316
SARATOGA, CA 95070
PHONE NO: (408)314-2892
❑ LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL U COMMERCIAL
License Class Lie. # 2
REMOVE (E) 157SQFT STORAGE ATTCHD TO CARPORT,
,� /
Contractor W «. i1� / Date _1 01�
�
CONSTRUCT 12SQFT ADD. TO BDRM 3, ADD 16SQFT FRNT
PORCH, INT REMODEL 714 SQ FT (SUNNYVALE
I hereby affirm that I aro licensed under the provisions o Chapter 9
SANITARY)
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
1 hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
Sq. Ft Floor Area:
Valuation: $94000
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
APN Number: 37527027.00
Occupancy Type:
permit is issued.
.APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. 1 agree to comply with all city and county ordinances and state laws relating
WITHIN DAYS OF PERMIT ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
180 DAY R LAST CALLED INSPE TION.
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
granting of thus permit. Additionally, the applicant understands and will comply
51-3
Issued by: + ' �t Date:
with all non -point source regulations per the Cupertino Municipal Code, Section
9.18.
RE -ROOFS:
1
Signature Date V J
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
❑ OWNER -BUILDER DECLARATION
Signature of Applicant: Date:
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
1, as owner of the property, or my employees with wages as their sole compensation,
wil I do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
1, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Codei Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(a) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self -insure for Worker's
material. Additionally, should 1 use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & Safety Code, Sections 25505, 25533, and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this
U
permit is issued.
Owner or authorized agent: Date
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any.manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with. all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
ARCHITECT'S DECLARATION
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
1 understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18.
Signature Date
CUPERTINO
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION�%�
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 \`V
(408) 777-3228 • FAX (408) 777-3333 • building o1cupertino.org
❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI Rr REVISION / DEFERRED ORIGINAL PERMIT # 13 01 0062-
PROJECT
06Z
PROJECT ADDRESS
S6o Imo,-
APN #
X75--2y-c�Z�
OWNER NAME .
Rs S. I�/la..vi
PHONE
14 o8 L131-'1-_�-,1e,
E-MAIL
STREET ADDRESS
10 s6 o c.-)LAk-d 1,Lt-- nr--
CITY, STATE, ZIP
c -A 95-0 ►yl
FAX
CONTACT NAME
„"
PHONE
yGf�-3�v-oo
E-MAIL 1
um�G Z1a82n �-C \.`
STREET ADDRESS
2A Ci �. 2_c3
CITY, STATE, ZIP
s Joss:_. cA s
FAX
yr, - 3-70 3-7`1
❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME
LICENSE NUMBER
LICENSE TYPE
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ARCHITECT/ENGINEER NAME
LICENSE NUMBER
BUS. LIC #
6,-772--)
COMPANY NAME _
�E-MAILa �
�.
FAX 3-7
P' 6 kin
� �-j
J[ f,
STREET ADDRESS
<
CITY, STATE, ZIP
-A5I1L
PHONE
409-2, --0'
DESCRIPTION OF WORK
EXISTING USE
PROPOSED USE CONSTR
TYPE
# STORIES
USE TYPE
OCC.
SQ.FT.
VALUATION (S)
EXISTG
NEW FLOOR
DEMO
TOTAL
AREA
AREA
AREA
NET AREA
BATHROOM
KITCHEN
OTHER
REMODEL AREA
REMODEL AREA
REMODEL AREA
PORCH AREA
DECK AREA
TOTAL DECK/PORCH AREA
GARAGE AREA: DETACH
❑ ATTACH
#DWELLING UNITS:
ISSECOND UNIT E] YES
SECOND STORY E] YES
BEING ADDED? []NO
ADDITION? ❑NO
PRH -APPLICATION ❑YES IF YES, PROVIDE COPY OF
PLANNING ADPL# ❑NO PLANNING APPROVAL LETTER
IS THE BLDG AN ❑YESr
EICHLER HOME? ❑NOr��//�����i�/��/�//..�//%�11
WTOTAL
VALUATION:
By my signature below, I certify to each of the following: I am the property owner or authedo5ed agent t0ir5t on property owner's behalf. I have read this
application and the information I have provided is correct I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-identifi property for inspection purposes. .
Signature of Applicant/ Agent: Date:
SUPPLEMENTAL INFO ATI REQUIRED
Q
/,%/;,X'1u#I!rGHEClCTYPE,,'1//i110f%Ir,RQ;,
— New SFD or Multifamily dwellings: Apply for demolition permit for
existing building(s). Demolition permit is required prior to issuance of building
permit for new building.
r, ///%////%�/%�i i ,n; iii �/ r i%r/�
( J/�iil ,/i �/ %✓/i�nry' lrrr��/%/i�/ G/yy11%!�%"%'
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
form if any Hazardous Materials are being used as part of this project.
Copy Planning Approval Letter Meeting Planning to
of or with Prior
submittal of Building Permit application.
�
Bldg,4pp_2011.doc revised 06/21/11
CITY OF CUPERTINO
FM_71 FEE ESTIMATOR - BUILDING DIVISION
imADDRESS:
10560 WUNDERLICH DR
DATE: 06/12/2013
REVIEWED BY: MELISSA
Plan Check Fee: Hourly Only? 0 Yes Q No
APN: 375 24 027
BP#:
'VALUATION: Iso
%PERMIT TYPE: Building Permit
PLAN CHECK TYPE: Alteration / Repair
PRIMARY SFD or Duplex
USE:
1'�1Zt bP 'v) I'Kc�
PENTAMATION 1GENRES
I PERMIT TYPE: A
WORK
REV # 1 - CHANGE ROOF PITCH TO 4:12
SCOPE
Suppl. Insp. Fee -0 Reg. 0 OT
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
District. etc). These fees are based on the nreliminary information available and are only an estimate Contact the Dent for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Eff 7/1/12)
b,
/'Yawh' 1'Irw b( 1,
MISC ITEMS
Plan Check Fee: Hourly Only? 0 Yes Q No
$0.00
2 hours Plan Check, Hourly
$266.00 1STPLNCK
0(hci lf' .'y7. Insp.
t�,�>111Pk' P/lo2() IY'!.`;1).
.
%f!v >Y f>>("'. iYUi/lLl
.14, (h 1 1J. Prr c:
1'�1Zt bP 'v) I'Kc�
FJ{��. ,(/?SU I'c('
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
District. etc). These fees are based on the nreliminary information available and are only an estimate Contact the Dent for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Eff 7/1/12)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee: Hourly Only? 0 Yes Q No
$0.00
2 hours Plan Check, Hourly
$266.00 1STPLNCK
Suppl. PC Fee: Q Reg. 0 OT0.0
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$0.00
Suppl. Insp. Fee -0 Reg. 0 OT
0,0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
Con,,7r°trc6on Tix:
E)
Work Without Permit? 0 Yes (j) No
$0.00
Advanced PlanningLee:
$0.00
Select a Non -Residential 0
Building or Structure 0
A
Strong Motion Fee:
$0.00
Select an Administrative Item
BldgStds Commission Fee:
$0.00
,/, i L1i6OTAL;+,
$0.00
$266.00 ,, Tt3TALEE`'
$266.00
Revised: 04/29/2013
CITY OF CUPERTINO
FEE ESTIMATOR - BUILDING DIVISION
w ADDRESS: 10560 WUNDERLICH DR
DATE: 0110912013
REVIEWED BY: MELISSA
APN: 375-24-027
BP#:
*VALUATION: 1$94,000
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE: Addition
PRIMARY SFD or Duplex
USE:
2nd Unit? GYes No
OTC? 0 Yes ONo
PENTAMATION I R3SFDADD
PERMIT TYPE:
WORK
REMOVE E 157SQFT STORAGE ATTCHD TO CARPORT CONSTRUCT 12SQFT ADD. TO BDRM
SCOPE
13, ADD 16SQFT FRNT PORCH, INT REMODEL 774 SQ FT
OCCUPANCY TYPE:
TYPE OF
CONSTR.
FLR AREA
s.f.
PC FEES
PC FEE ID
BP FEES
BP FEE ID
R-3 (Custom)
II-B,III-B,Iv,v-B
28
$1,014.00
IADDPLCK
$983.00
IADDINSP
filer. In'sp, PLY`
$983.00
Suppl. Insp. Fee.e Reg. Q OT
0,0
1 hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
l-"r�ypcsdmtat��aaar� �ti.r.r:
Work Without Permit? _ Yes (F) No
$0.00
TOTALS:
28
$1,014.00
"` ;.
$983.00
Strong Motion Fee: IBSEISMICR
ML+CT1E�T(IC3RI,Y „ Yes ,Q lc�;';
�
PIJtJMII, I4LTRi,Y Yes I�ia'aT
EC I301(IxY; Yom'%i,Np%
°,I'<I. Non C FaF r k �
Mond) /'Irnr o'hc < A,
1
Uf,c:. Man C hcc/a
i11'1r17' M'r'it J"(" :
Nffln%r. F'eoroif FCC
Uo 1'crmit Fisc.
P'ithca C9c:�°Jr, hrs/,
r' thcr )"borh Insp.
0(itur /'7'/'r Iruqt,
11�'c%a. Ft�s£�. £ r.^��:
atr'ath. Trrs£". %eye:
filer. In'sp, PLY`
NOTE. This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
District, etc). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Ef. 711112)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$1,014.00
=s.f. Remodel, Other
$534.00 1REMRESOTH
Supp). PC Fee: Q Reg. Q OT
0.0
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$983.00
Suppl. Insp. Fee.e Reg. Q OT
0,0
1 hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
l-"r�ypcsdmtat��aaar� �ti.r.r:
Work Without Permit? _ Yes (F) No
$0.00
Advanced Planning Fee.. IPLLONGR
$3.64
Select a Non -Residential 0
Building or Structure
A
T rale (,l 00cariricnilult. n
Strong Motion Fee: IBSEISMICR
$9.40
Select an Administrative ltem
Bl_ dg Stds Commission Fee: 1BCBSC
$4.00
BTOTAI✓
$2,014.04
$534.00 TOTALF
$2,548.04
Revised: 10/01/2012
CUPERTINO
CONTRACTOR / SUBCONTRACTOR LIST
Building Department
City Of Cupertino
10300 Torre Avenue
Cupertino, CA 95014-3255
Telephone: 408-777-3228
Fax: 408-777-3333
JOB ADDRESS:PERMIT
#
OWNER'S NAME:MAAI V1 R j9 ZTt-N D R4 4LfMI4
PHONE # 4�" � --'� / — 20'j Z
?
GENERAL CONTRACTOR: W "Al Cu
BUSINESS LICENSE #
ADDRESS 1 %f)
CITY/ZIPCODE:r.�
*Our municipal code requires all businesses working in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors:
Signature Date/
Please check applicable subcontractors and complete the following information:
j/
SUBCONTRACTOR
BUSINESS NAME
BUSINESS LICENSE #
Cabinets & Millwork
Cement Finishing
Electrical
Excavation
Fencing
Flooring / Carpeting
Linoleum/ Wood
Glass / Glazing
Heating
Insulation
Landscaping
Lathing
Masonry
Painting / Wallpaper
Paving
Plastering
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
Owner / Contractor Signature ate
BUILDING ENERGY ANALYSIS REPORT
doh r'
�� ,i1lfrtc� C Pfiilw
PROJECT:
FED 1 5 2013
Manvi Residence
10560 Wunderlich rive
Cupertino, CA 95014"p,,��fs.,Pw�9,,'
Project Designer:
Paladin Design & Engineering
249 S. 20th Street
San Jose, CA 95116
408-370-0730
Report Prepared by:
M. Jason Mundy
864 Green Street
Orangeburg, SC 29115
408-761-4483
.. .-
12-015 1 COP t �� �
Date:
1/31/2013
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
IThis program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by Energ Soft User Number: 5837 RunCode: 2013-01-31T13:37:42 1D: 12-015
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
EnergyPro 5.1 by EnergySoft Job Number. ID: 12-015 User Number: 5837
2
3
10
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Manvi Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1/31/2013
Project Address
10560 Wunderlich Drive Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area
1,904
Addition
12
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes 0 No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features (see Part 2 of 5) Status
Slab Unheated Slab -on -Grade
None 1,892 Perim = 175' Existing
Roof Wood Framed Attic
R-11 1,865 Existing
Wall Wood Framed
None 1,098 Existing
Door Opaque Door
None 20 New
Door Opaque Door
None 40 Existing
Wall Wood Framed
R-13 13 New
Slab Unheated Slab -on -Grade
None 12 Perim = 4' New
Roof Wood Framed Rafter
R-13 12 New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Skylight 9.0 0.710
0.73 none none None Existing
Skylight 9.0 0.710
0.73 none none None Existing
Skylight 9.0 0.370
0.29 none none None New
Front (N) 16.1 0.710
0.73 2.0 none Bug Screen Existing
Front (N) 11.0 0.710
0.73 2.0 none Bug Screen Removed
Front (N) 11.0 0.710
0.73 none none Bug Screen Existing
Front (N) 20.0 1.040
0.76 2.0 none Bug Screen Existing
Front (N) 8.5 0.550
0.57 2.0 none Bug Screen New
Right (W) 49.9 0.710
0.73 2.0 none Bug Screen Existing
Rear (SW) 20.0 1.040
0.76 2.0 none Bug Screen Existing
Rear (SW) 39.6 0.390
0.37 none none Bug Screen Altered
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
3 Packaged Heat Pump 8.20 COP
Hydronic Heat Pump 13.3 EER Setback Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Existing Ductless / with Fan
Ductless n/a n/a Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener ySoft User Number: 5837 RunCode: 2013-01-31713:37:42 ID: 12-015
Page 3 of 12
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
Manvi Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1/31/2013
Project Address
10560 Wunderlich Drive Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area
1,904
Addition
12
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features (see Part 2 of 5) Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Rear (SM 71.6 0.390 0.37 none none Bug Screen New
Rear (SM 6.0 0.710 0.73 none none Bug Screen Removed
Rear (S) 12.0 0.710 0.73 none none Bug Screen Removed
Leff (SE) 6.0 0.710 0.73 none none Bug Screen Removed
Right (Kq 11.6 0.710 0.73 2.0 none Bug Screen Removed
Right (Kq 10.6 1.040 0.76 2.0 none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener yPro 5.1 by Ener ySoft User Number 5837 RunCode: 2013-01-31T13:37:42 /D: 12-015
Page 4 of 12
'PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project. Name
Manvi Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/31/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by Ener Soft User Number. 5837 Run Code: 2013-01-31T13:37:42 !D: 12-015 Pa e 5 of 12
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
fl anvi Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
1/31/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 9.93 9.28 0.65
Space Cooling 17.28 12.87 4.41
Fans 5.30 4.12 1.18
Domestic Hot Water 19.28 19.28 0.00
Pumps 0.00 0.00 0.00
Totals 51.78 45.55 6.23
Percent Better Than Standard: 12.0%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 313 56
Fuel Available at Site: Natural Gas (E) 0 0
Raised Floor Area: 0 (S) 340 131
Slab on Grade Area: 1,904 (tM 745 61
Average Ceiling Height: 8.0 Roof 1,904 27
Fenestration Average U-Factor: 0.63 TOTAL: 274
Average SHGC: 0.57 Fenestration/CFA Ratio: 14.4
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company M. Jason Mundy
Y v�'�—
1/31/2013
Address 864 Green Street Name
City/State/ZipCity/State/Zip Orangeburg, SC 29115 Phone 408-761-4483 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Paladin Design & Engineering J
.,�,.. G7-72J
Address 249 S. 20th Street Name Quang Phan
City/State/Zip San Jose, CA 95116 Phone 408-370-0730 i;ned- License # Date
EnergyPro 5.1 by Ener Soft User Number 5837 RunCode: 2013-01-31T13:37:42 ID: 12-015 Page 6 of 12
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Manvi Residence
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/31/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Slab
1,8921
0.730 None
0
180 Existing 4.4.7-A 1
Living Area
Roof
1,865
0.079 R-11
0
0 Existing 4.2.1-A2
Living Area
Wall
238
0.356 None
0
90 Existing 4.3.1-A 1
Living Area
Door
20
0.500 None
0
90 New 4.5.1-A4
Living Area
Wall
269
0.356 None
1 270
90 1 Existing 4.3.1-A 1
Living Area
Door
20
0.500 None
270
90 Existing 4.5.1-A4
Living Area
Wall
27
0.356 None
0
90 Remove 4.3.1-A 1
Living Area
Wall
29
0.356 None
270
90 Remove 4.3.1-A 1
Living Area
Door
20
0.500 None
270
90 Existing 4.5.1-A4
Living Area
Wall
72
0.356 None
0
90 Removec 4.3.1-A1
Living Area
Wall
38
0.356 None
270
90 Existing 4.3.1-A 1
Living Area
Wall
195
0.356 None
225
90 Existing 4.3.1-A1
Living Area
Door
20
0.500 None
225
90 Remove 4.5.1-A4
Living Area
Wall
9
0.356 None
225
90 Remove 4.3.1-A 1
Living Area
Wall
11
0.356 None
180
90 Remove 4.3.1-A 1
IlLi vin Area
Wall
9
0.356 None
135
90 1 Remove 4.3.1-A 1
Living Area
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Skylight
9.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Living Area
2
Skylight
9.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Living Area
3
Skylight
9.0 0.370 NFRC
0.29 NFRC
0 New
Velux Comfort (75) Lowe2/Arg
Living Area
4
Window
11.3 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Living Area
5
Window
4.8 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Living Area
6Window
11.0 0.710 Default
0.73 Default
0 Removed Double Metal Clear
Living Area
7
Window
11.01 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Living Area
8
Window
10.0 1.040 Default
0.76 Default
0 Existing
Single Non Metal Clear
Living Area
9
Window
10.0 1.040 Default
0.76 Default
0 Existing
Single Non Metal Clear
Living Area
10
Window
4.3 0.550 Default
0.67 Default
0 New
Double Non Metal Clear
Living Area
11
Window
4.3 0.550 Default
0.67 Default
0 New
Double Non Metal Clear
Living Area
12
Window
6.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Living Area
13
Window
9.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Living Area
14
Window
16.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Living Area
15
Window
10.0 1.040 Default
0.76 Default
225 Existing
Single Non Metal Clear
Living Area
16
Window
10.0 1.040 Default
0.76 Default
225 Existing
Single Non Metal Clear
Living Area
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
I'D
Exterior Shade Type SHGC
Window
H t TWd
Ove hang Left Fin Right Fin
Len H t I LExt RExt Dist Len H t Dist Len H t
1
None
1.00
2
None
1.00
3
None
1.00
4
lBug Screen
0.76
3.0 3.8
2.0 0.1
2.0 2.0
5
Bug Screen
0.76
1.7 2.7
2.01 0.1
2.01 2.0
6
Bug Screen
0.76
2.7 4.0
2.0 0.1
2.0 2.0
7
Bug Screen
0.76
8
Bug Screen
0.76
2.0 10.0
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
2.0 10.0
2.0 0.1
2.0 2.0
10
IBuq Screen
0.76
6.6 0.6
2.0 0.1
2.0 2.0
11
JBug Screen
0.76
6.6 0.61
2.0 0.11
2.0 2.0
12
18ug Screen
0.76
2.0 3.0
2.0 0.1
2.0 2.0
13
Bug Screen
0.76
3.0 3.0
2.0 0.1
2.0 2.0
14
Bug Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
15
Bug Screen
0.76
2.0 10.0
2.0 0.1
2.0 2.0
16
Bug Screen
1 0.76
2.0 10.0
2.0 0.1
2.01 2.0
Ener
pro 5.1 by EnergySoft User Number: 5837 RunCode: 2013-01-31T13:37:42 ID: 12-015
Pa e 7 of 12
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Manvi Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1131/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U Insulation Joint Appendix
Factor Cavi Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Wall
0
0.102 R-13
225 90 New 4.3.1-A3
Living Area
Wall
358
0.356 None
270 90 Existing 4.3.1-A 1
Living Area
Wall
13
0.102 R-13
225 90 New 4.3.1-A3
Living Area
Slab
12
0.730 None
0 180 New 4.4.7-A 1
Living Area
Roof
12
0.069 R-13
0 0 New 4.2.2-A8
Living Area
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC2
Azm Status Glazing Type
Location/Comments
17
Window
39.6 0.390 NFRC
0.37 NFRC
225 Altered Milgard Classic Low -E Vinyl
Living Area
18
Existing
0.710 Default
0.73 Default
Double Metal Clear
pre -altered for above
19
Ofindow
16.0 0.390 NFRC
0.37 NFRC
225 New Milgard Classic Low -E Vinyl
Living Area
20
Window
6.0 0.710 Default
0.73 Default
225 Removed Double Metal Clear
Living Area
21
Window
12.0 0.710 Default
0.73 Default
180 Removed Double Metal Clear
Living Area
22
Window
6.0 0.710 Default
0.73 Default
135 Removed Double Metal Clear
Living Area
23
1 Window
39.61 0.390 NFRC
1 0.37 NFRC
1 225 New Milgard Classic Low -E Vinyl
Living Area
24
Window
7.6 0.710 Default
0.73 Default
270 Existing Double Metal Clear
Living Area
25
Window
4.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Living Area
26
Window
7.6 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Living Area
27
Window
11.3 0.710 Default
0.73 Default
270 Existing Double Metal Clear
Living Area
28
Window
5.3 1.040 Default
0.76 Default
270 Existing Single Non Metal Clear
Living Area
29
1 Window 1
5.31 1.040 Default
1 0.76 1 Default
270 Existing 1 Single Non Metal Clear
Living Area
30
Window
16.0 0.390 NFRC
0.37 NFRC
225 New Milgard Classic Low -E Vinyl
Living Area
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
IBug Screen
0.76
22
lBug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
2.71 2.7
2.0 0.1 2.0 2.0
25
Bug Screen
0.76
2.0 2.0
2.0 0.1 2.0 2.0
26
Bug Screen
0.76
2.7 2.7
2.0 0.1 2.0 2.0
27
Bug Screen
0.76
3.0 3.8
2.01 0.1 2.0 2.0
28
Bug Screen
0.76
1.5 7.0
2.0 0.1 2.0 2.0
29
Bug Screen
0.76
1.5 7.0
2.0 0.1 2.0 2.0
30
Bug Screen
0.761
1
Ener
Pro 5.1 by Ener Soft User Number: 5837 RunCode: 2013-01-31T13:37:42 ID: 12-015
Page 8 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Manvi Residence
Building Type
® Single Family ❑ Addition Alone
El Family 121 Existing+ Addition/Alteration
Date
1/31/2013
BUILDING ZONE INFORMATION
System Name Zone Name New
Floor Area
Existing Altered Removed Volume
Year Built
Existing Existing
1,892 15,136 1953
Addition 12 96
Totals 1 1,8921 01 01 1
HVAC SYSTEMS
System Name Qty. Heating Type Min. Eff.
Cooling Type Min. Eff. Thermostat Type
Status
Existing 3 Packaged Heat Pum 8.20 COP Hydronic Heat Pump 13.3 EER Setback
Existing
HVAC DISTRIBUTION
System Name Heating Coolin
Duct Location
Duct Ducts
R -Value Tested? Status
Existing Ductless/ with Fan Ductless n/a
n/a ❑
Existing
El
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
C:
0
in
°a
a —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum Outside
Buried
Ener Pro 5.1 by EnergySoft User Number: 5837 RunCode: 2013-01-31T13:37:42 ID: 12-015
Page 9 of 12
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Manvi Residence
Date
1/31/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or RCCA.
150(i): Heating systems are uippecl with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)l B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A. Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150(j)3A. Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned s ace.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number. 5837 RunCode: 2013-01-31T13:37:42 /D: 12-015 Page 10 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name Date
Manvi Residence 1/31/2013
§150(m)l : All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used: to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)l : Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tae is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
ro rammed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)8: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 byEnergySoft User Number: 5837 RunCode: 2013-01-31T13:37:42 ID: 12-015 Page 11 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Manvi Residence
1/31/2013
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§1'50(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5837 RunCode: 2013-01-31T13:37:42 ID: 12-015 Page 12 of 12
M
CU'PERTINO
January 3, 2013
Paladin Design
Attn: Quang Phan
24.9 S. 200, St.
San Jose, Ca 95116
OFFICE OF COMMUNITY DEVELOPMENT
CITY HALL
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3308 • FAX (408) 777-3333 • planningPcupertino.org
SUBJECT: MINOR RESIDENTIAL PERMVIT ACTION LETTER – Application RM -2012-24:
This letter confirms the decision of the. Director of Community Development, given on January 3 2013,
approving a Minor Residential Permit to extend a legal non-conformirig building Nall four (4) feet to
facilitate the construction of a single story addition, located at 10560 Wunderlich Drive, with the
following conditions:
1. APPROVED PROJECT
This approval is based on a plan set entitled, "Manvi Project - Remodel." consisting of five (5)
sheets labeled A0.0 to A3.0, dated September 4, 2012, except as may be amended by conditions in.
this resolution.
Z. NON -CO FQRM1NC FACILITY
The .nonconforming carport and. any other nonconforming facilities on. site are subject to the City's
Nonconforming Uses and Nonconforming .Facilities Ordinance (Chapter 19.140). The property
owner must contact the City prior to any alterations to any nonconforming facilities on site for
Planning Division review.
3. NON -CO% I O1ZWNG BUILDING WALL LINE COVENAN
11'r•ior to final occupancy, the property owner shall contact the Planning Division, to draft a
covenant document that restricts future extensions of non-conforr-ning wall lines for the Life of the
house. The covenant shall be recorded with the Santa Clara County Clerk Recorder's Office,
4. ACCURACY OF THE PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data including but
not limited to property boundary locations, building setbacks, property size, build.ing square
footage, any relevant easements and./or construction records. Any misrepresentation of any
property data may invalidate this approval and may require additional review.
5. CONSULTATION WITH OTHER DEPAR71'1` —NTS
The applicant is responsible to consult with other departments and/or agencies with .regard to the
Mliwyr Residential Perroit Action Letter Page 2
RIM -201 2-24
proposed ptoject for aciditiorial conditions axi.d Any nasrepresen.tation of any
submitted datelrnay i'livalidate an approval by tli,,.- Cornniuni�y Devt,.,,,]oF)xnent Department.
6. EXTERIOR BUILDING ]VIATERIA LS AT'VIENTS
LLKA.
Fji,lal, bUilding e>Je-rk)r treatnient plan (Lricludinc, but not lirriited tc,) dke[afls on exterio'r color,
lnau.�rjal, architectural t-reatments and/or embellisl'u-lunts) sl a]l be reviec,ved and approved by the
Director of Community Dreveloprilent prior to is-sua-ince ckf building The final buildin)
exterior plan shiall closcl�, re sern'He the details showri on iurlt>11'1�14 rlpploveck 'plaj'"ts.
extericw changes determined to be sub,,tantial. b\,,, the Director of Cornnnunity Development shall
re,qUi,-e a minor modification approval with neigllborhoad inP ut,
D 1� LVA.
�-EDJCA,T1QNTS RHE'R 'ITONS. )R OTHER EXA""FION"'
The Conditions of Project Alpproval. set forth herein may include, cortain fees, dedication
requirements, reservatioii requirements, -and other exactioiis, Pursuarit tt') Governnient Code
Section 66()20(d) (1), these Conditions constituite w-fitten notice of i statemc,,nt of the annount of
such fees, arid a description of O -ie otl-ter a.''xactions. You are hereb.,y,
fu.,,.-ther notified that the 90 -da), approval period, in which vou nnav protest thesf.-? fees, dedications,
reservahon, , auid otlier ex.actions, pursuamt to Governrnent Code Sectiort 66020(a), has begun. l.t
-rT,U, f,Iil to file a protuit within this, 90 --day period, widi zill of Lhe requirement's of
66020, ou vvT1 be le&"-Zj7N7 fretjr" 1,
'Iter chadlenging ';u"Ch
Stzaff has made all the findings that are required for appn..wal a Mixlor Residential Pen -nit as required
by the of Cupertino's �Munjcipal- Code, Chapter 19.28.1-10 (). Also, please note that zu-i appeal of this
decision can be made withiri 14 calendar days frorn the date of this letter. If this happens, you will
be no"'Uf.ed of a pu.blic hcaring, lie Sch,,'-�dtiledl before flie Plann.-no, Coxruxiissin—n.
�
Siricerely,
Erv,losi..ires:
Approved Mari ears
Rajend-ra N'larivi, 10560 1,'V1.Hlde'HJd1h Dr, 0.-up(,1,,rti-,,i(') Ca 9,501
Residcwffid'RM, R&RM 12-24 .Adana e I k'rAtx
Diana Pancholi
Tntt',:rim Associate
Planner
%.Jty of Cupectil "10
4 0 8 - 7 77- "3319
d i a na u per till 0, 0 rg
Erv,losi..ires:
Approved Mari ears
Rajend-ra N'larivi, 10560 1,'V1.Hlde'HJd1h Dr, 0.-up(,1,,rti-,,i(') Ca 9,501
Residcwffid'RM, R&RM 12-24 .Adana e I k'rAtx