Loading...
15010089CITE' OF CU PIERTINO BUILDING PERMIT BUILDING ADDRESS: 10201 TORRE AVE CONTRACTOR: SPRIG ELECTRIC PERMIT NO: 15010089 OWNER'S NAME: I & G DIRECT REAL ESTATE 21 LP 1860 S IOTH ST DATE ISSUED: 01/15/2015 OWNER'S PHONE: 4086560289 SAN JOSE, CA 95112 PHONE NO: (408)298-3134 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL E] 0- 10 LAB 126- INSTALL (4) ]EV CHARGING STATIONS 20 AMP License Class Lic. # Contractor 50vi`7 L&Ze C,LVi Date 1 hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $5000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 36941005.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT )Ci XPIERES rF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHINg�® �� �� �������� ®� to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 OAFS ]FRO AS LL ED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Aitionally, the applicant understands and will comply Issued by: Date: / with all non -point sour egulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signatur _ Date /S/ All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: 1 hereby affirm that 1 am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, wil I do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous 1 have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Ba rea Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the ertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sect' 1 5, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized ag Date: S S permit is issued. 1 certify that in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, 1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, 1 must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked, work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION rr`` COMMUNITY DEVELOPMENT DEPARTMENT e BUILDING DIVISION Vv 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 \� CUPERTINO (408) 777-3228 • FAX (408) 777-3333 • buildingCokupertino.org 1� ❑ NEW CONSTRUCTION ❑ ADDITION [:]ALTERATION / TI ❑ REVISION /DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS ' �+� O '77v v I c V APN # s�/n % 4-1065 OWNER NAME /G 1 / 2 6 L ^ / P iL� I /l6 / n %1 �/ U zaq E-MAIL STREET ADDRESS CITY, STATE, ZIP FAX CONTACT NAME PHONE E-MAIL ^ ADDRESS _J7 CIT TATE/l. FAX R-20/ 5-Y-0-1 ❑ OWNER OWNER -BUILDER OWNER AGENT CONTRACTOR CONTRACTOR AGENT ❑ ARCHITECT 11 ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME . l (� LICENSE NUMBE� LICENSE TYPE LIC # COMPANY NAME E-MAIL f r ^yBUS. j FAX 1 l�C,l ( t' STREET ADDRESS 1&50 CITY, E, ZIP'f PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK EXISTING USE PROPOSED USE CONSTR. TYPE #STORIES USE TYPE OCC. SQ.FT, VALUATION (S) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: EIDETACH ❑ ATTACH # DWELLING UNITS: IS A SECOND UNIT ❑ YES SECOND STORY []YES BEING ADDED? ❑NO ADDITION? [:]NO PRE -APPLICATION ❑YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEIVED BIK. TOTAL VALUATION: PLANNINGAPPL# ❑NO PLANNING APPROVAL LETTER EICHLER HORIE? ❑NO y �j By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on roperty ner's behalf. I have read this application and the information I have provid d is correct. I have read the Description of Work and verify it is accurate. agree to comply with all applicable local ordinances and state laws relating to buil construction. I authorize representatives of Cupertino to enter the abov7ddti fie roperty for inspection purposes. Signature of Applicant/Agent: Date: �^ SUPPLEM L INFORMATION REQUIRED Pic PLAN CHECK T1TE Ro G SLIP OVER-THE°COUNTER ❑ BUIL�G PLAN REVIEW New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building " y permit for new building. ❑ EXPRESS PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure El STANDARD.. ❑ PUBLIC WORKS , form if any Hazardous Materials are being used as part of this project. El LARGE El FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_201 Ldoc revised 06/21/11 A"1llr07R7 ATTrl A"1Tr TTfTTr1""MTlTATW-T FEEFEEESTIMATORESTIMATOR �l.11 JL Y I1111[' t1. �1J1C1[`iILQ llll1�7 U.N - BUILDING DIVISION PliII0. Plan ("hc;c% ADDRESS: 10201 torre ave DATE: 0111512015 REVIEWED BY: Mendez APN: BP#: 'VALUATION: 1$5,000 PERMIT TYPE: Building Permit l'huil& hisp. Fee: PLAN CHECK TYPE: Tenant Improvement hrs PRIMARY Commercial Building PME Plan Check: PENTAMATION SOLAR -COMM USE: Permit Fee: PERMIT TYPE: d WORK lab 126- install 4 ev charging stations SCOPE PME Unit Fee: $0.00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc). These fees are based on the nreliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1/13) r9F�ch. 1'Icrrt Ckwci; PliII0. Plan ("hc;c% t eL.. Phm Check Veclt, i'2i tP1rl 1'i ': 1 (rur.h. Pani: 1'e -e.. lilee P� rtrru l e " 0;lrcr AI_ch. frup. 0(hicr Pfwn , (rnsp.Ll Gibe-• Flea. In=p. fi,'ech. /rasa. Fee: l'huil& hisp. Fee: 1�1"'t I,=ash. I cc"" NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc). These fees are based on the nreliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1/13) FEE QTY/FEET MISC ITEMS Plan Check Fee: $0.00 ® # $436.00 Alternative Energy System ICHRGSTA EV Charging Station Suppl. PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 TUX: 0 Work Without Permit? 0 Yes 0 No $0.00 Advanced Planning Fee. $0.00 Select a Non -Residential Building or Structure 0 0 d Tta1=t ?)tic(t�n�,�I; nrr 1�'c�E�t: ri Stronp, Motion Fee: IBSEISMICO $1.40 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $2.40 $436.00 TOTAL FEE: $438.40 Revised: 01/06/2015 CT2020 Family ChargePoint` charging stations, by Coulomb Technologies, offer municipalities, corporations, fleets and utilities, highly reliable electric vehicle charging that drivers prefer. The easy-to-use stations provide multiple power options, integrating aesthetics and ergonomics with sturdy construction—ideal for residential, commercial and outdoor public applications. The CT2020 dual charging stations provide two 7.2 kW (208/240 V @ 30 A) Level II charging ports and are designed for public outdoor applications for the North American marketplace. Charging is delivered via standard SAE J1772" connectors attached to self -retracting' cords. To enhance safety and eliminate energy theft, drivers access and energize the station using a ChargePoint card or contactless credit card. The station's highly visible display -- cr r at, r go6�'"__ Vacuum Florescent Display with Multiple Language Support Display instructions and messages in many languages on the bright, easy -to -read display. Integrated Fault Detection + Ground Fault Detection: Integrated ground -fault detection circuitry with autto retry and driver notification. + Over -Current Detection: Disconnects power to prevent nuisance breaker trips at service panel. Auto retry and driver notification. + Plug -Out Detection: Algorithm disengages power and notifies the driver when a plug is removed. guides drivers with instructive messages and can be used to Over -the -Air Station U grade display targeted messages for drivers. Keep charging stat' , ent with evolving EV needs by upgrading sta ar emotely over -the -air. Software Application Services S Set pricing and collect fees, provide 247 driver assistance, Utility d, e n Meter control access, enable reservations, display advertisements, P ;cdpe i -directional energy measurement with track usage and monitor the station remotely using the growing , j t ~gc!power metering circuitry. suite of ChargePoint cloud -based service plans. 01 dote Diagnostics and Control Utility Light' Minimize the need for on-site Provide drivers with the visibility they need to startd )Eth maintenance with remote, charging sessions in areas with poor lighting conditio , real-time alarm monitoring and energy-efficient, photosensor -activated light. control. Hassle -Free Cord Management' Network Interface Eliminate the need for drivers to coil up the SAE J1772" cord Wireless and cellular network with the CT2025's self -retracting cord management system, interfaces allow seamless ensuring that the cord is always off the ground when not in use. integration with ChargePoint Smart Card Reader cloud -based application services. Provide optional driver billing and custom access control, preventing electricity theft and enhancing safety, with an Smart Grid Compatible integrated standards-based RFID reader that accepts Enable Time -Of -Use JOU) ChargePoint cards, contactless credit cards and MIFARE-based pricing and demand response transportation cards. by integrating with Advanced Intelligent Power Control Metering Infrastructures (HMIs). Ensure power is delivered only when a driver is authorized and the EV connector is properly inserted. ' Included on the CT 2025 only. CT2021 charging station CharaePoint CT2020 Family CT2021 Mechanical Drawings 1 30? CT2023 Mechanical Drawings 14.8 in 375.8 mm 2 wwu.char9epoint.com 8.8 in 222.8 mm 17.4 in 441.9 mm 55 1409 M 141' 214.8 mm 214.8 mm [y7.1 mm 375.8 mm 0 CT2020 Family Specifications Electrical Input Input Power 7.2 kW (x 2) Input Voltage 208/240 VAC Input Current 30 A (x 2) Input Power Connections Line Al, Line A2, Earth, Line Bl, Line B2 (two independent 40 A branch Power Measurement circuits, each providing Line 1 and Line 2, and a single protective Earth Local Area Network conductor) Required Service Panel Breaker ; 40 A double pole breaker (non-GFCI type) on dedicated circuit (x 2) standby Power typtca (not me u Ing L ig i Ixture) Electrical Output Output Charging Power 7.2 kW (x 2) Output Voltage 240 VAC (x 2) Output Current 30 A (x 2) Output Charging Connector SAE J1772"' EV Connector on 18'(5.48 m) cord (x 2). On CT2025 only, cord is self -retracting. Functional Interfaces Lighting Photosensor -activated 9 W LED light (equivalent to 50 W incandescent) Card Reader ISO 15693,14443 Ground Fault Detection 20 mA CCID with auto retry (15 minute delay, 3 tries) Plug -Out Detection Power terminated per SAE J1772'" specification Power Measurement 2% @ 15 minute intervals Local Area Network 2.4 GHz 802.15.4 dynamic network Wide Area Network Commercial GPRS or CDMA cellular data network Safety and Operational Ratings Safety Compliance UL Listed for USA and cUL certified for Canada; Complies with UL 2594, vOL 2231-1, UL 2231-2, UL 1998, UL 991, NEC Article 625 Surge Protection 6 kV w 3,000. In geographic areas subject to frequent thunderstorms, supplemental surge protection is recommended, EMC Compliance FCC Part 15 Class A Operating Temperature -221F to 1221F (-30°C to +50°C) Operating Humidity 9594 non -condensing Enclosure Type 3R Teimnal Block Temperature 100°C (212° F) Rating Maximum Charging Stations 24. Each station must be within 150 feet "line of sight" of one gateway per 80235.4 Radio Group station. Wind Loading Up to 150 mph (241 kph). On the CT2025, includes a 12" x 18" (30 cm x 46 cm) additional signage area. Approximate Shipping Weights CT2021: 45 lbs (20.4 kg) CT2023 45 Itis (20.4 kg) CT2025: 98 Ibs (44.5 kg) Irc6Kled on the CT7075 nnly. Lu Ixrh Techn Joy+e, Inc. res,;gves llte right to alter pruduct a(er:ngs.35x1 SI & l`rCciruns dt any tine without not'Le and is not responsible fix typographical cr graohiral crr,:rs that may app:ar in this docurnent. www.chargepolnt.com 3 ChargePoint CT 2020 Family CT2025 Mechanical Drawings 9 244 299.9 mm Ordering Information Specify model number followed by the applicable code(s). The order code sequence is: Model -Modem -SIM -Card Reader -Warranty .... . .... . ....... . . . . 01, WIW 1T7�-TFN Model Mount StS6dard B611ard M06 t C 0--- T2 21 Wall Mount , C T2 0 2 3 MIIAM66rit with Top Lamp a"Ie, it.T20.2-51' Retractors Modem Integral GPRS ChargePoint Gateway -GPRS Modem Integral CDMA ChargePoint Gateway -CDMA Modem Sim USAGPRS SIM ...... ...... . .. . . . ... ......... 'j':-SIM1 . . Canada GPRS SIM -SIM Card Reader Contactless Credit Card Reader -CCR Warranty S.Year Parts Only Extended Warranty: ­EW5 syear Oariibnly Extended Wairranty 4,EWSGW Gateway, . Ordering Code Examples RMINION, IBM, 1121- Sfa*ndara Bollar_ d MoOrit with CT2021-GPRS GPRS Modem Bollard Mount with Top Lamp and CT2025-GPRS-SIM2 Cable Retractors, GPRS Mode, Canada GPRS SIM -Standard Bollard Mount with USA i. CT2021-GPRS-SIM1-CCR-,,EW5GW.� Modem, tactless Credit 0 in Card l4eader, and 5'Year Warranty Imm For More Information Visit www.chargepoint.com Follow us on Twitter @chargepointnet Like us on Facebook @chargepoint ChargePoint. Access anywhere. Go everywhere. Coulomb Technologies, Inc. 2CH-?.0012 Oo�lcmb Te:hnrlogel 1;t AA,rqt-,t; re--F-,ed :H,%�',GEFGVQT,z a US. morF ar.- I., Eij reg.s%�-,,d 1692 Dell Avenue lag--rl�,!k 0! Te'7—cloge. !,C. All otnef rta, a" 1 �'?Iai- ihe o - M fst J4 th, r �VI'C-- Campbell. CA 95008-6901 USA ce ,1.408.370.3802 Pq 73 001,-kD21 qzv S toll free 877.370.3802 LCA1W-1Y0Vjet�.,!r,*eis c@ us wwwxhargepolntxom usTEu ChargePolnt CT2020 Family CT2021 Mechanical Drawings 1' 303 CT2023 Mechanical Drawings 37. 2 www.chargepoint.com 441.9 mm 55 1409 5E 141 —4, 8.5 in �d- 214.8 mm 214.8 mm 199.1 mm Sly.e mm FJ CT2020 Family Specifications Electrical Input Input Power 7.2 kW (x 2) Input Voltage 208/240 VAC Input Current 30 A (x 2) Input Power Connections Line Al, Line A2, Earth, Line Bl, Line B2 (two independent 40 A branch Power Measurement circuits, each providing Line 1 and Line 2, and a single protective Earth Local Area Network conductor) Required Service Panel Breaker ; 40 A double pole breaker (non-GFCI type) on dedicated circuit (x 2) -"'Standby' Power-_.._ ................. ................. _.._.._............................................ 7W -tYPicat (not tnctutliiig LEi7 6gtiFfiztilre) Electrical Output Output Charging Power 7.2 kW (x 2) Output Voltage 240 VAC (x 2) Output Current 30 A (x 2) Output Charging Connector SAE .11772 " EV Connector on 18' (5.48 m) cord (x 2). On CT2025 only, cord is self -retracting. Functional Interfaces Lighting Photosensor -activated 9 W LED light (equivalent to 50 W incandescent) Card Reader ISO 15693,14443 Ground Fault Detection 20 mA CCID with auto retry (15 minute delay, 3 tries) Plug -Out Detection Power terminated per SAE J17721" specification Power Measurement 2% @ 15 minute intervals Local Area Network 2.4 GHz 802.15.4 dynamic network Wide Area Network Commercial GPRS or CDMA cellular data network Safety and Operational Ratings Safety Compliance Surge Protection EMC Compliance Operating Temperature Operating Humidity Enclosure Ter=minal Block Temperature Rating Maximum Charging Stations per 80235.4 Radio Group Wind Loading Approximate Shipping Weights UL Listed for USA and cUL certified for Canada; Complies with UL 2594, vUL 2231-1, UL 2231-2, UL 1998, UL 991, NEC Article 625 6 kV a 3,000. In geographic areas subject to frequent thunderstorms, supplemental surge protection is recommended, FCC Part 15 Class A -22'F to 1221F (-30°C to +50°C) 95% non -condensing Type 3R 100°C (212° F) 24. Each station must be within 150 feet "line of sight" of one gateway station. Up to 150 mph (241 kph). On the CT2025. includes a 12" x 18" (30 cm x 7'46 cm) additional signage area. CT2021: 45 lbs (20.4 kg) CT2023 45 lbs (20.4 kg) CT2025: 98 Ibs (44.5 kg) ' Irc6Kled on th(i CT2075 nnly. Wj:xr i TechnJoy,e, Inc. r t rves tlw right to alter pruduct a(erp as.3;xJ s!%° =`rc<irw�s dl ally time wdlwu[ nolwe and is not res ansible hx typographKal � yranhira! err::rs tt>at may appear ir, this docurna:nt. vvww.chargepolnt.cam 3 Cha, gePvrnt CT 2020 Fai r.Ay CT2025 Mechanical Drawings S 24� 14.6 in 370.4 mm 299.9 mm Ordering Information Specify model number followed by the applicable code(s). The order code sequence is: Model -Modem -SIM -Card Reader -Warranty Ordering Code Examples Standard Bollard Mount with CT2021-GPRS GPRS Modem " Bollard Mount with Top Lamp and CT2025-GPRS-SIM2 Cable Retractors, GPRS Mode, Canada GPRS SIM -Standard Bollard Mount with USA i,CT2021-GPRS SIMI-CCR�EW5GW GPRS Modem, Contactless Credit D'" Card Reader, grid 5 Year Warranty For More Information Visit www.chargepoint.com Follow us on Twitter @chargepointnet Like us on Facebook @chargepoint ChargePoint. Access anywhere. Go everywhere. Caul omb'Technologies, Inc."coy VV ? ecu -71017 coalmJ ie=bn !cgie L^.c ..Sewrmt ;-mH =.rH„GEr.Gn.arQrT.,.z iae Ur...S.'nzrzr�s >2r:: ;,d._em :.r c'erwg -= erreo:r6rr=zr;a an' 1692 Dell Avenue Or . -'chge: ;'e All e're:ro: req srt -,1 r eya. Campbell. CA 95008-6901 USA =''ce myrv;n` tor. resa :?wE av t +1.408.370 3802 °'` Riv 5 toll free 877.370.3802 c 1_u > iw=,v,:r.+i a tIL us wvrvwxhargepolnt.com LIM Model StandardBollard Mount :.CT2021 Wall Mount 4CT2023 µBollard Mount with Top Lamp and,Cable CT2o25 M Retractors Modem Integral GPRS ChargePoint Gateway -GPRS Modem Integral CDMA ChargePoint Gateway -CDMA Modem SIM USA GPRS SIM, SIM, Canada GPRS SIM: SIM2 Card Reader Contactless Credit Card Reader -CCR Warranty 5 Year Parts Only Extended Warranty, EW5 5<Year Parts Only Extended Warranty -EWSGW-�:^ Gateway Ordering Code Examples Standard Bollard Mount with CT2021-GPRS GPRS Modem " Bollard Mount with Top Lamp and CT2025-GPRS-SIM2 Cable Retractors, GPRS Mode, Canada GPRS SIM -Standard Bollard Mount with USA i,CT2021-GPRS SIMI-CCR�EW5GW GPRS Modem, Contactless Credit D'" Card Reader, grid 5 Year Warranty For More Information Visit www.chargepoint.com Follow us on Twitter @chargepointnet Like us on Facebook @chargepoint ChargePoint. Access anywhere. Go everywhere. Caul omb'Technologies, Inc."coy VV ? ecu -71017 coalmJ ie=bn !cgie L^.c ..Sewrmt ;-mH =.rH„GEr.Gn.arQrT.,.z iae Ur...S.'nzrzr�s >2r:: ;,d._em :.r c'erwg -= erreo:r6rr=zr;a an' 1692 Dell Avenue Or . -'chge: ;'e All e're:ro: req srt -,1 r eya. Campbell. CA 95008-6901 USA =''ce myrv;n` tor. resa :?wE av t +1.408.370 3802 °'` Riv 5 toll free 877.370.3802 c 1_u > iw=,v,:r.+i a tIL us wvrvwxhargepolnt.com LIM