Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13070003
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 19863 LINDENBROOK LN CONTRACTOR: QUALITY GENERAL PERMIT NO: 13070003 CONSTRUCTION OWNER'S NAME: PATRICK WONG 138 NIAGARA AVE DATE ISSUED: 09/24/2013 OWNER'S PHONE: 4089309624 SAN FRANCISCO, CA 94112 PHONE NO: (415) 336-5657 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ ADDITION OF 991 S.F. TO CREATE 2 (N) BEDROOMS, I License Class��Lic. (N) 1/2 BATH, (N) LIVING RM, DINING RM & LAUNDRY ' 1 I 3 1 RM. REMODEL, (E) KITCHEN, BATHROOMS & BEDROOMS Contractor Date 6 (700 1 hereby affirm that 1 am licensed under the rovisions f Chapter 9 REVISION # 2 - REPLACE (E) FURNACE, SAME LOCATION - ISSUED 3/6/I4 (commencing with Section 7000) of Divisiob of the Business & Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's C p sation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $200000 form ice of the work for which this permit is issued. will maintain Worker's Compensation Insurance, as provided for by 6e on00 of the Labor Code, for the performance of the work for which this Uperis APN Number: 36923015.00 Occupancy Type: ssued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is PjERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN Igo DAYS 45 ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to saveeed 0 ED INSPE TION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which ma accrue against said City in consequence of the D granting of this permit. Addit nally, a applicant understands and will comply y: Date: with all non -point source re u do per the Cupertino Municipal Co , Section 9.18. %� RE -ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the B rea Air uality Management District 1 performance of the work for which this permit is issued. will maintain compliance with the Cup tino Chapter 9.12 n I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25 5�25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date: ZA permit is issued. I certify that in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, 1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date 0T Y OF SCUP ER'I[ NO OMNI FEE IESTMATOR — HUMMNG ID)ffVffSffON APPLIANCE / EQUIP TYPE ADDRESS: 19863 LINDENBROOK LN /DATE: 03/06/2014 REVIEWED BY: MELISSA UNITS APN: 369 23 015 BP#: 13070003 *VALUATION: Iso *PERMIT TYPE: Mechanical Permit PIAN CHECK TYPE: Alteration / Addition / Repair PRIMARY USE: SFD or Duplex # PENTAMATION PERMIT TYPE: FURN/AC WORK REVISION # 2 - REPLACE E FLIRNACE SAME LOCATION - ISSUED 3/6/14 SCOPE StIpPl. Lrsp Fee APPLIANCE / EQUIP TYPE FEE IID !'hewn') Platt C llec-A, Perna' P��c: wr Phdf,b InspLl I Plu++rb. hisp. N", - QTY UNITS S Furnace, Forced -Air 1MFR=<100 1 # $139 � !�' V 1'r•rrria I �c:: StIpPl. Lrsp Fee PME Unit Fee: $139.00 PME Permit Fee: $47.00 C.OR1 ,_O'W'C1Q7 KTA. Administrative Fee: IADMIAr tl Work Without Permit? 0 Yes E) No TOTALS: 'I dvolleed Planning Fees: a $139.00 $47.0.2' NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the Preliminary information available and are only an estimate. Contact the Dept for addn'l info. ]FEE ITEMS (Fee Resolution 11-053 E . 71/!13) Mech. Plan Check 0,0 hrs $0.00 MechffiPermit !'hewn') Platt C llec-A, Perna' P��c: wr Phdf,b InspLl I Plu++rb. hisp. N", - L.1e, . Fl:r f"�Y)NIl FeOther Oar';t ; Jik r Insp. Fsl- F .c,. n1AMPPE[Arnh. Mech. Insp.) A'Icc h. /asp- Fre: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the Preliminary information available and are only an estimate. Contact the Dept for addn'l info. ]FEE ITEMS (Fee Resolution 11-053 E . 71/!13) ]FEE QTY/]FEE MISC ITEMS PlarT Check Fee: S1117pl. PC":' F'ev PME Plan Check: $0.00 � !�' V 1'r•rrria I �c:: StIpPl. Lrsp Fee PME Unit Fee: $139.00 PME Permit Fee: $47.00 C.OR1 ,_O'W'C1Q7 KTA. Administrative Fee: IADMIAr tl Work Without Permit? 0 Yes E) No 'I dvolleed Planning Fees: a Travel Documentation Fee: ITRAVDOC $47.0.2' Strom Motion Fee: $0.00 Select an Administrative Item BIS Stds Commission Fee: $0.00 E__ SUBTOTALS: I $277.00 $0.00 TOTAL- EE: $277.00 Revised: 01/15/2014 CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT ^ BUILDING DIVISION, - 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUpRTINO (408)7 77-3228 ^ FAX (408) 777-3333 buildingecupertino.org ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI J4 REVISION / DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS ( j 0D ���-APN # UU OWNER NAME -6( Y, LICENSE NUML DEMO PHONgllo! E-MAIL COMPANY NAME f� 1 / u+ E-MAIL AREA NETAREA FAX 1I STREET ADDRESS 3 p I r f ( r, STREET ADD SS ! � KITCHEN PHONE/ I p��g`� U CITY, STAT, ZIP Vo3 CA FAX CONTACT N By my signature below, I certify to each of the ollowing: I am the property owner or authorized agent to act on the property owner's behalf. I have read this BUS. LIIC(-4 PHONE Signature of Applicant/Agent: Date: �/ Z� E-MAIL STREET ADDRESS PORCH AREA CITY, STATE, ZIP FAX FAX 13 OWNER ❑ OWNER -BUILDER El OWNER AGENT 11 CONTRACTOR 11 CONTRACTOR AGENT 11 ARCHITECT 1:1 ENGINEER 11 DEVELOPER 11 TENANT CONTRACTOR NAME ISA 1,tLU1VU Urv11 U Y=. LICENSE NUML DEMO LICENSE TY& BUS. LIC 4 y COMPANY NAME f� 1 / AREA E-MAIL AREA NETAREA FAX 1I STREET ADDRESS 3 p I r f ( r, CITY, STAT /� (� KITCHEN PHONE/ I p��g`� U ARCHITECT/ENGINEER NAME LICENSE NUMBER REMODEL AREA By my signature below, I certify to each of the ollowing: I am the property owner or authorized agent to act on the property owner's behalf. I have read this BUS. LIIC(-4 COMPANY NAME Signature of Applicant/Agent: Date: �/ Z� SUPPLEMENTAL INF RMATION REQUIRED E-MAIL PORCH AREA DECK AREA FAX STREET ADDRESS existing building(s). Demolition permit is required prior to issuance of building 0lfti COUNTER CITY, STATE, ZIP permit for new building. EXPRESS PHONE DESCRIPTION OF WORK V -Z L/ r��x r �.U, Ai ❑ PUBLIcwoRxs form if any Hazardous Materials are being used as part of this project.: , g . C� 6 "LARGEa a FIRE DEPT rr . ` Copy of Planning Approval Letter or Meeting with Planning prior to 1] IaAroR Q snNrraRx sTPRnISTRrcr > n submittal of Building Permit application. tXISI NUUSE PRUPOSEU USE CO NSIR IYft #STUR1ts USE TYPE OCC. SQ.FT. VALUATION (S) EXJSTG ISA 1,tLU1VU Urv11 U Y=. NEW FLOOR DEMO TOTAL BEING ADDED? []NO, AREA AREA AREA NETAREA IS THE BLDG AN ❑ YES CEIVED B - -- TOTAL VALUATION: BATHROOM EICHLER HOME?`_; KITCHEN OTHER w..3 REMODEL AREA By my signature below, I certify to each of the ollowing: I am the property owner or authorized agent to act on the property owner's behalf. I have read this REMODEL AREA REMODEL AREA Signature of Applicant/Agent: Date: �/ Z� SUPPLEMENTAL INF RMATION REQUIRED . PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: LJ DETACH existing building(s). Demolition permit is required prior to issuance of building 0lfti COUNTER REVIEW permit for new building. EXPRESS ❑PLANNING PLAN REVIEW ❑ ATTACH r sTANDARD r��x r �.U, Ai ❑ PUBLIcwoRxs form if any Hazardous Materials are being used as part of this project.: 8 Uwt1.IdNU Un11S: ISA 1,tLU1VU Urv11 U Y=. bMUNU MUMY U Yra BEING ADDED? []NO, ADDITION? []NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES CEIVED B - -- TOTAL VALUATION: PLANNING APPL B ❑ NO PLANNING APPROVAL LETFER EICHLER HOME?`_; - w..3 By my signature below, I certify to each of the ollowing: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is corr t. I have read the Description of Work and verify it is accurate. I a ee to comply with all applicable local ordinances and state laws relating to building c ns c ion. I authorize representatives of Cupertino to enter the abo e-ide fled p perty for inspection purposes. Signature of Applicant/Agent: Date: �/ Z� SUPPLEMENTAL INF RMATION REQUIRED PLAN CHECK.TI'PE *BOUTING'SLiP D illi ❑ BUII DIIVG PLAN New SFD or Multifamily dwellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building 0lfti COUNTER REVIEW permit for new building. EXPRESS ❑PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure r sTANDARD r��x r �.U, Ai ❑ PUBLIcwoRxs form if any Hazardous Materials are being used as part of this project.: , g . C� 6 "LARGEa a FIRE DEPT rr . ` Copy of Planning Approval Letter or Meeting with Planning prior to 1] IaAroR Q snNrraRx sTPRnISTRrcr > n submittal of Building Permit application. ._- ... _ •-*.. 0"�F.NVI77()NMR.NTdT. Fi7!B7.TF; ...r. B1dgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 19863 LINDENBROOK LN CONTRACTOR: TBD - TO BE PERMIT NO: 13070003 DETERMINED OWNER'S NAME: PATRICK WONG DATE ISSUED: 09/24/2013 OWNER'S PHONE: 4089309624 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDEN RAL L1 COMMERCIAL License Class Lic. # ADDITION OF 991 S.F. TO CREATE 2 (N) BEDROOMS, 1 (N) 1/2 BATH, (N) LIVING RM, DINING RM & LAUNDRY Contractor Date RM. REMODEL (E) KITCHEN, BATHROOMS & BEDROOMS I hereby affirm that I am licensed under the provisions of Chapter 9 (700 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. REVISION 01- REVISION TO LATERAL DESIGN IN FAMILY I hereby affirm under penalty of perjury one of the following to.declarations:. OM-ISSD OTC 10/14/2013 I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Lab prode, for the performance of the work for which this pe ®�provided Sq: Ft Floor Area: Valuation: $200000 I have and will maintain Worker's Compensation In uranSection 3700 of the Labor Code, for the pe APN Number: 36923015.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMI EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WIT 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 D S FROM LAST CALLED INSP TION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Issued by: Date: granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, l agree to remove all new materials for inspection. 0ry�-i OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) , as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. II will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this t ?�� Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must l hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked, work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. l agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the l understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. l Signature Date COMSTRUC7110H PERVUHT APPUCQMOM COMMUNITY DEVELOPMENT DEPARTMENT ^ BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 CUP[ERTINO (408) 777-3228 • FAX (408) 777-3333 - buildWOwperUmpra ❑NEWCONSTRUCTION ❑ ADDITION ❑ALTERATION/Tl 1,'1' REVISIONIDEFFRRFD ORIGINAL PERMIT# FBI °ROJECI' ADDRESS ® Q (9 1T �, U �s MINER NAME o PHONE®(o0 � �q �,1� C•MAIL PnAn °�� pO STREET ADDRESS :71 CITY,STATE, Ewa ��® FAM ° an PHONE pP.•MAIL CONTACT NAMEAIA W P (q7 p �0 0 STREET ADDRESS CITY, STATE, YIP F 01VNER ❑ OWNER•BUILOF.R ❑ OWNER AGENT ❑ CONTRACTOR ❑ co?,TRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME i V ZAewp LICLNSF;NUMBER nn0&P (Y LJCENSETYPE BUS LICO COMPANY NAME 1'rl ,•MAIL FAX STILEEI' ADDR 'SS / CITY. STATE. ZIP P o o o a ria g PHONE xv-arp ARCHtTF.CT/ENOINF.ER AME SC®,et CUL , o LICENSE NUMBER C A. j9 �ra r�!KT'Lut� BUS LICA -&o-5 ?��� COMPANY COMPANY NAME /'I�ottl Pbt e4'''r15 lt,it• (^ �( `,.r-.�1 EMAIL .DGS OoM:�vvU PAx STREET ADDRESS ( h 5 q � o5tq p V4 , Q � 1 (� Y /�1t 9by� `''J CTIT, STATN, UP � � g r�,y � 9 PHONF, DESCRIPT10N OF WORK I MSTING USE PROPOSED USE CONS R 1'YPe 0STORIGS USE TYPE OCC. SQ,FT. VALUATION (S) F.x sTG AREA NEW FLOOR AREA DEMu AREA TOTAL NETARF:A DATIMOOM R&MODEL ARL•A KITCHEN REMODEL AREA uniER KENODeLAYFA POR—CI I aREn DECK ARBA TOTAL DECKIPORCH AREA GARAGE AREA: DETACH ATTACH RDWF.I.IJNGUNRS: ISAS—EC O—No LT11' — YES SECONDSTORV yv' � RFINC ADDED! IJNO ADDITION? ❑\0 PRE AFPLICATIUNYES IF YES, PROVIDE COPY OF IS THE BLDG, PLANNTNGAPPL:V HNO PLANNINGAPPROVAI.I.ICI•rGR EICHLERNOME? (�N0 CEIV40,p TO YAL ON; g tc. owner's behalf. 1 have rend this By my signature below, I certify to each of the following: 1 am the property owner or authorized o act on th application and the information I have provided is correct, I have read the Description of Work and verily it is accurate. 1 agree to comply with all applicable local idened p perty for inspection purposes. ordinances and state laws relating to ing construction I authorize representatives of Cupertino to enter the ebo a t(ti Signature of ApplicanUAgent; Date: c�'='--,� SUPPLEMENTAL INFORMATION REQUfAED PI.ANPIFC1CTVPH ROuTINGSLIP 01V R-TILo-:C.IDIMER 13SUILD11 MAN=VIKW ❑ CSJPRF_m ❑ PLAMM FLAN REVIaW _ New SFD or Multifamily dwellings: Apply for demolition permit for existing building(&). Demolition permit is required prior to issuance of buildin permit for new building. _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure 1:1STAIN)ARD 13C Imrollvow form if any Hazardous Materials are being used as part of this project. ❑ I.ARt,Q ❑ F[RSD3PT _ Copy of Planning Approval better or Mecting with Planning prior to submittal of Building Permit application. ❑ RLaI�a sAtteriaRtrs�RDtsTa1> t ❑ P. r+IVJHONIWENTAL HEALTH B1dgApp_M1-doc revised 06/21111 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 19863 LINDENBROOK LN CONTRACTOR inn T n PERMIT NO: 13070003 OWNER'S NAME: PATRICK WONG a DATE ISSUED: 09/24/2013 OWNER'S PHONE: 4089309624 U PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL U COMMERCIAL License Class O Lic. # d �� ADDITION OF 991 S.F. TO CREATE 2 (N) BEDROOMS, A Contractor Date (N)1/2 BATH, (N) LIVING RM, DINING RM & LAUNDRY RM. REMODEL (E) KITCHEN, BATHROOMS & BEDROOMS I hereby affirm that I m license u der the provisions of hapte 9 (700 (commencing with Section 7000) of ivision 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $200000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 36923015.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. 1 agree to comply with all city and county ordinances and state laws relating WITHIN 1 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 1801 AYS OM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the q_1*12. granting of this permit Additi Ily, the applicant understands and will comply Issued by: Date: with all non-point sou re ations per the Cupertino MunicipalCo ,Section 9.18. ,f� �—`t' 2z RE-ROOFS: Signature Date 0All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. R will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by t eBay Area Quality Management District I performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by will maintain compliance with th Cuperti Municipal Code, Chapter 9. 2 and the Health & Safety Code, Section 2550 , and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date: Z permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION 'QP COMMUNITY DEVELOPMENT DEPARTMENT . BUILDING DIVISION 00 10300 TORRE AVENUE ^ CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 . building(d1cupertino.org / �) CUPERTINO ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION/ DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS APN # 36 OWNER NAME PHONEE-MAIL �� 6N v�► evIV011 STREET ADDRESS / / � CrrYyK TE B FAX ® COISIACr NAME PHONE ®�� [� v E!' d / JV �I Q S Pgh ®Wako- STREET ADDRESS CITY, STATE, ZIP FAX ❑ O\ R`NER ❑ OWNER -BUILDER ❑ OWER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT �I ARCHITECr ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECr/ENGINEERNAME n-'� LICENSE NUMBER BUS. LIC# COMPANY NAME L�Qr` E-MAILX FAX � � �® STREET ADDRESS 58 I"jF.A-Ao..,io '.6 die CITY, STATE, ZIP sow �'/aSe PHONE DESCRIPTION OF WORK N4 2 MW %Loe EXISTINGUSE PROPOSED USE CONSTR. TYPE # STORIES / V R V. USE TYPE OCC. SQ.FT. VALUATION (S) EXISTG 1 NEW FLOOR DEMO TOTAL AREA / 1-7 AREA O s AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ ATTACH # DIVELLING UNITS: IS A SECOND UNIT ❑ -, ES SECOND STORY ❑ YES BEINGADDED? ED ADDITION? ❑NO PRE -APPLICATION ❑YES IF YES, PROVIDE COPY OF 1S THE BLDG AN ❑ YES CEI '' v TOTAL VALUATION: PLANNING .ADPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO _ By my signature below, I certify to each of the following: I am the property owner or authorized agen o ac o property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above'-iide tiff %d property for inspection purposes. , Signature Applicant/Agent: Date: /� of SUPPLEMENTAL INTORMATION REQUIRED CHECKTIPE<c�___.._-.-,. - New SFD or Multifamily dwellings: Apply for demolition permit for ' r,R m OVERTH1 qou-'TIP ❑ BiBLDII�cPL�ANREVIEw existing building(s). Demolition permit is required prior to issuance of building l� Y Permit for new building. `© EXPRESS `fl PI. VIEW z LANI.II�GFAn REOWN Commercial Bldgs: Provide a completed Hazardous Materials DisclosureOPLBiic�tixxs s+" *5``t iF _ v.. a4111 ot" _ form if any Hazardous Materials are being used as part of this project. LAI2G$ - FIRFTIEPT a y r s�3 J _ Copy of Planning Approval Letter or Meeting with Planning p,-ior to 11IAJOR SANITARYSER'E,RDISTRICP submittal of Building Permit application. .❑ ,,,,.-,-..y.;,. ,�. E?i'1TI201�'MENTAZEEALTH. B1d.aApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION NI ADDRESS: 19863 LINDERBROOK LN IDATE: 07/01/2013 REVIEWED BY: MELISSA MI APN: 369 23 015 BP#: 115v &103 `VALUATION: 1$200,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex 2nd Unit? Yes ' No PENTAMATION 1 R3SFDADD USE: OTC. C) Yes E)No PERMIT TYPE: WORK ADDITION OF 983 S.F. TO CREATE 2 N BEDROOMS 1 N 1/2 BATH N LIVING RM DINING RM SCOPE & LAUNDRY RM. REMODEL (E) KITCHEN, BATHROOMS & BEDROOMS (700 S.F.) OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA 1 s.E PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) II-B,111-B,IV,V-B 983 $2,468.00 IR3PLNCK $1,549.00 IR3INSP Elec. Insp. Fee: PNIE Plan Check: $0.00 Permit Fee: $1,549.00 Suppl. Insp. Feee. Reg. OT O. 07 hrs $0.00 PME Unit Fee: $0.00 TOTALS: 983 1 $2,468.00 1 $1,549.00 MECH, HOURLY Yes E) No PLUMB, HOURLY Q Yes Q No ELEC, HOURLY ® Yes Q No Xkch. Plan Check P/umb. Plan ClrerA- L"hc. Plan Cheek :iil,h. Permil Fee: Plumb. Permil Fee: _�_ Elec. Permi; Fee: Other .Meeh. lnsp. Li I Other Plumb lnsh.El Other Flee. Insp. Aaech. Insp. Fee: Plumb. Insp. Fee: Elec. Insp. Fee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District. etc). These fees are ha.ced on the nreliminary information available and are only an estimate. Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 711/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,468.00 700 s.f. $534.00 Remodel, Other IREARESOTH I I ozi I Suppl. PC Fee: 0 Reg. 0 OT FO.0 hrs $0.00 PNIE Plan Check: $0.00 Permit Fee: $1,549.00 Suppl. Insp. Feee. Reg. OT O. 07 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 ("Onsiruction Tax: fl.d+3?LrllSt,+"Cltl'vC' .I' E'L': 0 0 Work Without Permit? Yes Q No $0.00 Advanced Planning Fee: IPLLONGR $127.79 Select a Non -Residential Building or Structure 0 A I rug el Uoca�rnentcltian 1%`c cis: Strong Motion Fee: IBSEISMICR $20.00 Select an Administrative Item 1 Bldg Stds Commission Fee: IBCBSC $8.001 SUBTOTALS: $4,172.791 $534.001 TOTAL FEE: 1 $4,706.79 Revised: 04/29/2013 CUPERTONO ( 1�) 011 a 111 i 1j1 I I. �1( 1111 I I I ti I BuRding Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 JOB ADDRESS: k,-,kiv\ '�, PERMIT # 0 --360 () OWNER'S NAME: a, C1 PHONE # C N r GENERAL CONTRACTO : �� _ ('v� BUSINESS LICENSE # ADDRESS: CITY/ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR (FINAL OCCUPANCY INSPIECTEON(S) WILL BE SCHEDULED tJNUL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF C UPlERT>INO BUSINESS LICENSE. I am not using any subcontractors: d Signature Date ?lease check applicable subcontractors and complete the following infformation: Owner /dontractor Signature s As -/Z,-) Date 2 SUBCONTRACTOR BUSINESS ESS NAMIE BUSI<N ESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating O�5 Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner /dontractor Signature s As -/Z,-) Date 2 Owner Name Address WATER -CONSERVING PLUMBING FIXTURES [� OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION F1 F'-'wl 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building aacupertino.org F �f I CA � 1/j Permit Please refer to the attached California Civil Code Sections 1101.1— 1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: M No Go to Question 2. +` Date: S-/Z2_//'f 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. ` / Owner' Signature: �J No Go to Question 3. Date: �-12 Z�l 3. Is water service permanently disconnected -for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. _/ Owner' Signature; /�Date: X12 2� 1 '63 No Go to Question 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 110 1. 1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signatureqisust Date: U Yes My real property anlable fo se or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. "y property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless . of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB407 2014. doc revised 03118114 CALIFORNIA CIVIL CODE SECTIONS 1101.1-1101.8 Civil Code Division 2. Property Part 4. Acquisition of Property r o Title 4. Transfer Chapter 2. Transfer of Real Property Article 1.4. Installation of Water Use Efficiency Improvements ........ 1101.1 —1101.8 1101.1. The Legislature finds and declares all of the following: (a) Adequate water supply reliability for all uses is essential to the future economic and environmental health of California. (b) Environmentally sound strategies to meet future water supply and wastewater treatment needs are key to protecting and restoring aquatic resources in California. (c) There is a pressing need to address water supply reliability issues raised by growing urban areas. (d) Economic analysis by urban water agencies has identified urban water conservation as a cost-effective approach to addressing water supply needs. (e) There are many water conservation practices that produce significant energy and other resource savings that should be encouraged as a matter of state policy. (f) Since the 1991 signing of the "Memorandum of Understanding Regarding Urban Water Conservation in California," many urban water and wastewater treatment agencies have gained valuable experience that can be applied to produce significant statewide savings of water, energy, and associated infrastructure costs. This experience indicates a need to regularly revise and update water conservation methodologies and practices. (g) To address these concerns, it is the intent of the Legislature to require that residential and commercial real property built and available for use or occupancy on or before January 1, 1994, be equipped with water -conserving plumbing fixtures. (h) It is further the intent of the Legislature that retail water suppliers are encouraged to provide incentives, financing mechanisms, and funding to assist property owners with these retrofit obligations. 1101.2. Except as provided in Section 110 1.7, this article shall apply to residential and commercial real property built and available for use on or before January 1, 1994. 1101.3. For the purposes of this article: (a) "Commercial real property" means any real property that is improved with, or consisting of, a building that is intended for commercial use, including hotels and motels, that is not a single-family residential real property or a multifamily residential real property. (b) "Multifamily residential real property" means any real property that is improved with, or consisting of, a building containing more than one unit that is intended for human habitation, or any mixed residential -commercial buildings or portions thereof that are intended for human habitation. Multifamily residential real property includes residential hotels but does not include hotels and motels that are not residential hotels. (c) "Noncompliant plumbing fixture" means any of the following: (1) Any toilet manufactured to use more than 1.6 gallons of water per flush. (2) Any urinal manufactured to use more than one gallon of water per flush. (3) Any showerhead manufactured to have a flow capacity of more than 2.5 gallons of water per minute. (4) Any interior faucet that emits more than 2.2 gallons of water per minute. (d) "Single-family residential real property" means any real property that is improved with, or consisting of, a building containing not more than one unit that is intended for human habitation. (e) "Water -conserving plumbing fixture" means any fixture that is in compliance with current building standards applicable to a newly constructed real property of the same type. (f) "Sale or transfer" means the sale or transfer of an entire real property estate or the fee interest in that real property estate and does not include the sale or transfer of a partial interest, including a leasehold. 1101.4. (a) On and after January 1, 2014, for all building alterations or improvements to single-family residential real property, as a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department, the permit applicant shall replace all noncompliant plumbing fixtures with water - conserving plumbing fixtures. 01 UILDING E JERGY ANALYSIS REPORT PFOJECT: Mr. Patrick Wong's Residence 19863 Lindenbrook Dr. Cupertino, CA 95014 Project Desiicgnero �%vid Wong Home Deign and Consultant � 958 Meadowood Drive San Jose, CA 95120 408-997-2735 61 P►�F•»►f-�� t.�y: Mark Chu & Associates 1141 S. Stelling Rd. Cuperl:ino, CA 95014 (408) 255-4804 Job dumber: .010313 Date: 9/2/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number. 4970 RunCode: 2093-09-02T07:56:33 1D: 010313 1 PERFORMANCE CERT11MCATE o Resp denVd0 Part 1 of 5 CF -1 R Project Name Mr. Patrick Wong's Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 9/2/2013 Project Address 19863 Lindenbrook Dr. Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,181 Addition 991 # of Stories 1 FIELD MSPEcrm ENERGY CHECKLIST KL -IST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. NSULATON Construction Type Area Special Cavity (0 Features see Part 2 of 5 Status Roof Wood Framed Attic R-30 1,175 Existing Wall Wood Framed R-13 910 Existing Door Opaque Door None 18 Existing Floor Wood Framed w/Crawl Space None 1,190 Existing Roof Wood Framed Attic R-30 973 Radiant Barrier New Wall Wood Framed R-13 626 New Door Opaque Door None 34 New Floor Wood Framed w/Crawl Space R-19 991 New FENESTRATION UUe Exteftrr Orientation Areal(ft) Factor SHGC Overhang SidJefins Shades Status Skylight 4.0 0.290 0.38 none none None New Skylight 4.0 0.290 0.38 none none None New Skylight 4.0 0.290 0.38 none none None New Skylight 3.0 0.290 0.38 none none None New Left (W) 79.0 0.370 0.32 none none Bug Screen New Left (lM 13.0 1.190 0.83 none none Bug Screen Removed Rear (N) 24.0 1.190 0.83 none none Bug Screen Existing Rear (N) 51.0 1.190 0.83 none none Bug Screen Removed Rear (N) 65.5 0.370 0.32 none none Bug Screen New Right (E) 129.0 0.370 0.32 none none Bug Screen New Right (E) 24.0 1.190 0.83 none none Bug Screen Removed HVAC SYSTEMS 01y. Heating Win. Ef(f Cooliin6lfilin. E f Thermostat Status 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC msTR11BU11ON Localtilon Heating DUC2 Cooflng Duct Location R-ftue Status Res HVAC Ducted Ducted Attic, Ceiling Ins, vented 6.0 New WATER HEATING @t . TyRe Gallons Mlln. Ef f Distaff ion Status 1 Instant Gas 0 0.84 No Pipe Insulation New Ene Pro 5.1 by Ene Soft User Number: 4970 RunCode: 2013-09-02107:56:33 ID: 010313 Page 2 of 12 PERFORMANCE C ERT06 ICAT1 Eo ResWenftl] Part 1 of 5 CF IR Project Name Mr. Patrick Wong's Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 9/212013 Project Address 19863 Lindenbrook Dr. Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 2,181 Addition 991 # of Stories 1 HELD [INSPECTM E MERGY C HECKUST1 ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ® Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. WSUILA'fr°m AIrea Speciall Construction Type Cavity (ft) Features see pan 2 of 5 Status FENESTRAT[ON U- Extevioir ®Irientation Area(ft) Factor SKGCC Overhang Sidefins Shales Status Skylight 18.0 0.290 0.38 none none None New Front (S) 68.0 0.370 0.32 none none Bug Screen New HVAC SYSTEMS Ota He�n Min. Efif CooUng Wn. Eiit TIhevmostat Status HVAC DWROU1fW Duct Location Heating CoOng Duct Locaftn R -Vallee Status WATER HEATNG Oto Type Gallons Rine Ell Distribution Status Ene Pro 5.1 PZ Ener Soft User Number. 4970 RunCode: 2013-09-02T07:56:33 ID: 010313 Pa e 3 of 12 PERFORMANCE CERTIf;mIIC ATE: Resp dWW (Pari 2 of 5) CSG -1 R Project Name Mr. Patrick Wong's Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 9/2/2013 SPEUQLL FEATURES 1INSPEC 110H C HECKLIS7 The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-30 Roof Attic with Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.22. WEBS REQUIRED MEGA PIC AIRON Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number: 4970 RunCode: 2013-09-02T07:56:33 /D: 010313 Page 4 of 12 PERFORMANCE CERT ICATE: ResWeMW (Part 3 of 5) CF-I R Project Name Building Type 0 Single Family ❑ Addition Alone Date Mr. Patrick Wong's Residence ❑ Multi Family ® Existing+ Addition/Alteration 9/2/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftZ- r Space Heating 34.90 26.55 8.35 Space Cooling 13.84 10.73 3.11 Fans 7.66 6.56 1.10 Domestic Hot Water 17.96 13.75 4.21 Pumps 0.00 0.00 0.00 Totals 74.36 57.59 16.78 Percent letter Than Standard: 22.6 BUOLDING C MPLOES o NO HERS WER1I1F0Q V0(DO M REQUORED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 393 68 Fuel Available at Site: Natural Gas N 516 79 Raised Floor Area: 2,181 (N) 526 90 Slab on Grade Area: 0 (E) 517 129 Average Ceiling Height: 8.0 Roof 2,181 33 Fenestration Average U-Factor: 0.42 TOTAL: 399 Average SHGC: 0.35 Fenestration/CFA Ratio: 18.3% REMARKS STATEMENT Ofd COMPUANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. ®®cumero$a$u®ro Aau$6v®ir C--/�/�� C�- Mark Chu & Associates Company 9/2/2013 Address 1141 S. Stelling Rd. Name City/State/ZipCity/State/Zip Cupertino, CA 95014 Phone (408) 255-4804 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company David Wong Home Deign and Consultant 958 Meadowood Drive David Won Address Name 9 City/State/Zip San Jose, CA 95120 Phone 408-997-2735 Signed Li ense # Date Ener Pro 5.1 b Ener Soft User Number: 4970 RunCode: 2013-09-02T07:56:33 ID: 010313 Page 5 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. Patrick Wong's Residence Building Type 0 Single Family ❑ Addition Alone Date ❑ Multi Family ® Existing+ Addition/Alteration 9/2/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,175 0.031 R-30 0 22 Existing 4.2.1-A20 1st Floor Zone (E Wall 138 0.102 R-13 180 90 Existing 4.3.1-A3 1st Floor Zone E Door 18 0.500 None 1 180 90 Existing 4.5.1-A4 1st Floor Zone E Wall 155 0.102 R-13 270 90 Existing 4.3.1-A3 1st Floor Zone E Wall 183 0.102 R-13 0 90 Existing 4.3.1-A3 1 st Floor Zone E Wall 302 0.102 R-13 90 904.3.1-A3 1st Floor Zone E Wall 237 0.356 None 180 904.3.1-A 1 1 st Floor Zone E Floor 1,190 0.097 None 0 180 Existing 4.4.1-A1 1st Floor Zone E Wall 133 0.102 R-13 0 904.3.1-A3 1st Floor Zone ERoof 973 0.031 R-30 0 224.2.1-A20 1st Floor Zone (N Wall 283 0.102 R-13 270 90 New 4.3.1-A3 1st Floor Zone (N) Wall 87 0.102 R-13 90 90 New 4.3.1-A3 1st Floor Zone N Wall 136 0.102 R-13 180 90 New 4.3.1-A3 1st Floor Zone N Door 34 0.500 None 180 90 New 4.5.1-A4 1st Floor Zone N Wall 121 0.102 R-13 0 90 New 4.3.1-A3 1st Floor Zone N Floor 1 9911 0.037 R-19 1 01 180 1 New 14.4.1-A4 I 1st Floor Zone (N FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Skylight 4.0 0.2901 COG 0.38 1 COG 0 New Viracon VE -1-2M 1st Floor Zone (E) 2 Skylight 4.0 0.2901 COG 0.38 COG 0 New Viracon VE -1-2M 1st Floor Zone (E) 3 Skylight 4.0 0.290 COG 0.38 COG 0 New Viracon VE -1-2M 1st Floor Zone (E) 4 Skylight 3.0 0.290 COG 0.38 COG 0 New Viracon VE -1-2M 1st Floor Zone (E) 5 Window 12.5 0.370 NFRC 0.32 NFRC 270 New /WC 5300 VinyULow-E 1st Floor Zone (E) 6 Window 24.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 VinyULow-E 1 st Floor Zone (E) 7 1 Window 13.0 1.190 Default 0.83 Default 270 Removed Single Metal Clear 1st Floor Zone (E) 8 Window 24.01 1. 1901 Default 0.83 Default 0 Existing Single Metal Clear 1st Floor Zone (E) 9 Window 51.0 1.190 1 Default 0.83 Default 0 Removed Single Metal Clear 1st Floor Zone (E) 10 Window 53.5 0.3701 NFRC 0.32 NFRC 0 New IWC 5300 VinyULow--E 1 st Floor Zone (E) 11 Window 40.0 0.3701 NFRC 0.32 NFRC 90 New I IWC 5300 Vinyl/Low-E 1st Floor Zone (E) 12 Window 17.5 0.370 NFRC 0.32 NFRC 90 New IWC 5300 VinyULow-E 1 st Floor Zone (E) 13 1 Window 1 24.0 1.190 Default 0.83 Default 1 90 Removed Single Metal Clear 1st Floor Zone (E 14 Skylight 18.0 0.290 COG 0.38 COG 0 New Viracon VE -1-2M 1st Floor Zone (N) 15 Window 6.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 VinyULow-E 1st Floor Zone (N) 16 Window 12.5 0.370 NFRC 0.32 NFRC 270 New IWC 5300 VinyULow-E 1st Floor Zone (N) (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hq7F7Wd Ove hanq Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 Bug Screen 0.76 6 Bug Screen 0.76 7 lBug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 None 1.00 15 Bug Screen 0.76 16 Bug Screen 0.76 EnergyPm 5.1 by Ener Soft User Number: 4970 RunCode: 2013-09-02T07:56:33 ID: 010313 Page 6 of 12 CERTIFICATE OF C®MP DANCE: ResWenftll (Part 4 of 5) CF -1 R Project Name Mr. Patrick Wong's Residence Building Type 2 Single Family ❑ Addition Alone Date ❑ Multi Family ® Existing+ Addition/Alteration 9/2/2013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior I Frame Interiorl Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 24.0 0.370 NFRC 0.32 NFRC 270 New IWC 5300 VinyULow-E 1st Floor Zone (N) 18 Window 16.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 VinyULow-E 1st Floor Zone (N) 19 Window 40.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 Vinyl/Low-E 1st Floor Zone (N 20 Window 3.5 0.370 NFRC 0.32 NFRC 90 New IWC 5300 VinyULow-E 1st Floor Zone (N) 21 Window 12.0 0.370 NFRC 0.32 NFRC 90 New IWC 5300 VinyULow-E 1st Floor Zone (N) 22 Window 7.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyULow-E 1st Floor Zone (N) 23 Window 24.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyULow-E 1 st Floor Zone (N) 24 Window 6.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyULow-E 1 st Floor Zone (N) 25 Window 7.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 VinyllLow-E 1st Floor Zone (N) 26 Window 24.0 0.370 NFRC 0.32 NFRC 180 New IWC 5300 Vinyl/Low-E 1st Floor Zone (N) 27 Window 12.0 0.370 NFRC 0.32 NFRC 0 New IWC 5300 VinyULow-E 1st Floor Zone (N) (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len Hat LExt RExt Dist Len Hat Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 Ener Pro 5.1 bX EneMKSoft User Number. 4970 Run Code: 2093-09-02707:56:33 ID: 010313 Page 7 of 12 CCRTIRCAM OF COMPLIANCE: ResMeMW (Part 5 of 5) CF -1 R Project Name Mr. Patrick Wong`s Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 9/212093 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Res HVAC 1st Floor 1,190 9,520 1960 1st Floor 991 7,928 Totals 1 991 1,190 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Res HVAC 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Res HVAC Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ New WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Takagi T -K2 1 Instant Gas No Pipe Insulation 185,000 0 0.84 n/a n/a New MULTI -FAMILY WATER (HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 a U) Q System Name Pipe Length Pipe Diameter Insul. Thick. Oty. HP Plenum Outside Buried ❑ Ener Pro 5.1 by Ener Soft User Number: 4970 RunCode: 2093-09-02T07:56:33 ID: 010313 Page 8 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MFa1 R Project Name Mr. Patrick Wong's Residence Date 1 9/2/2013 *NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements o §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-09-02707:56:33 ID: 010313 Page 9 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. Patrick Wong's Residence 9/2/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, 2iping, filters, and valve requirements of J150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or.greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-09-02707:56:33 ID: 010313 Page 10 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3. MF®1 R -Project Name Date Mr. Patrick Wong's Residence 9/2/2093 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number. 4970 RunCode: 2013-09-02707:56:33 1D: 010313 Page 11 of 12 HVAC SYSTEM HEA7MG AND COOLING LOADS SUMMARY Project Name Mr. Patrick Wong's Residence Date 9/2/2013 'System Name Res HVAC Floor Area 2,181 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 957 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 94,000 20,055 956 629 29,844 Total Output (Btuh) 94,000 0 Output (Btuh/s ft) 43.1 910 1,657 Cooling System o 0 Output per System 46,300 0 0 0 0 Total Output (Btuh) 46,300 0 956 0 Total Output (Pons) 3.9 910 1,657 Total Output (Btuh/s ft) 21.2 Total Output s ft/Ton 565.3 21,875 33,159 Air System CFM per System 1,570 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,570 Carrier 58MTB100-16 CNP 38HD 4 T 40,526 3,373 94,000 Airflow (cfm/s ft) 0.72 Airflow (cfm/Ton) 406.9 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 40,526 3,373 94,000 Aug 3 PM Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions HEATING SYSTEMA PSYCHROMAETRICS (Airstream Teme2ratures at Time of Heating Peak 28 OF 69 OF 69 OF 115 OF 0 Outside Air 0 cfm Supply Fan Heating Coil 1,570 cfm 69 OF 114 OF W UUAiI^� WOODUu , 70 OF COOLING SYSTEMA PSYCHROMAETICS (Airstream Temperatures at Time of Cooling Peak) 88/68°F 76/62°F 76/61°F 55/54°F 0 - Outside Air 0 cfm Supply I Fan Cooling Coil 1,570 cfmI�l 76 / 62 OF fw 56 / 54 OF 46.0 % ROOK � • ' . 75 / 61 OF EnergyPro 5.1 by EnergySoft User Number: 4970 RunCode: 2013-09-02T07.56:33 ID: 010313 Page 12 of 12