31831
APPLICANT TO FILL IN INFORMATION WITHIN RED LINES - USE BALL POINT PEN ONLY
r�
O
Z ZX
F-
LU
LU >
CL 0
D Z
Uo
LL I -
Ow
} (L
to
F-
A A
x
BUILDING PROJECT IDENTIFICATION
BUILDING APPLICATION & PERMIT
ADDRESS
BUILDING - ELECTRICAL- PLUMBING - MECHANICAL
P MI ER
318 3
OWNER'S - ----"-"� - _ -�--�
PLAN CHECK VALIDATION
NAME QTY. ELECTRIC PERMIT FEE
PHONE
co TRACTOR s
NAME ,. ""
OUTLETS - SWITCHES - RECEP 5.00/1.00 ae
IC.No.p
-
LIGHTING FIXTURES 5.00/1.00
ro TRACTOR'S
ADDRESS
APPLIANCESRESIDENTIAL 4.00
PANELS ` 5.00
PHONE
DATE OF APPLICATION
ARCHITECT "
OR
ENGINEER
• LIC. NO.
SIGNS. 6.00
PLAN CHECK FEE
'
P.C. NO.
SIGNS TRANS. " 3.00
ADDRESS ENG. ' •" -
SPECIAL CIRCUIT -'5.00
PERMIT VALIDATION
EMP. METER OR POLE INS. 15.00
ziP
A
ANrs
ADDRESS `
MOTORS, '• SEE FEE SCH.
SERVICE CHANGE 10.00
a- ate-
LICENSED CONTRACTORS DECLARATION
•
I hereby affirm that 1 am licensed under provisions of Chapter 9
commencing with Section 7000) of Division 3 of the.Business and
Profesessions Codx nd y license is in full force eff
Licenlass - Lic. Number
ISSUANCE DATE
BLDG.
ELECT.-
❑
I PLG.
❑
MECH.
❑
Date - Contractor
BUILDING PERMIT
INFORMATION
OWNER -BUILDER DECLARATION
hereby affirm that I am exempt from the Contractor's License
Law for the following reason. (Sec..7031.5, Businessand Professions.
Code: Any city or county which requires a permit to construct, alter,
improve, demolish, or repair any structure, prior to its'issuance, also
requires the applicant for such permit to file a signed statement. that
he is licensed pursuant to the provisions of the Contractor's License
MISC. - REFER TO ORD
�
PERMIT ISSUANCE 6.00
VALUATION
00
6, F" .'
.$/FT.
ELEC. CONTR. LIC. NO.
ELEC. Q•O
TOTAL l
PERMIT TO
-
QTY. PLUMBING PERMIT FEE
.Law (Chapter 9 (commencing with Section 7000) of Division 3 of the
Business and Professions Code) or that he is exempt therefrom and
STORIES
TYPE CONSTR.
the basis for the alleged exemption. AFiy violation of Section 7031.5
-
by any applicant for a permit subjects the applicant toa civil penalty
of not more than:five hundred dollars (5500).):
A TER -DRAIN &VENT -WATER (EA.) 4.00
C1 1, as ownei.of the property, or my employees with wages as
iheir sole compensation, will do the work, and the structure is not
BAC FLOW PROTECT. DEVICE -2.00
'
OCC. GROUP
RES. UNITS
DRAIN LOOR, ROOF, AREA,COND. 4.00
intended or offered for sale (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of
FIXTURES PER TRAP 4.00
SO. FT. FLOOR AREA
TOTAL ACREAGE
properly who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improve-
ments. are not intended or offered forsale.lf,;however,the building
GAS - EA.SYS EM-11NC-400TLETS 4.00
or improvement is sold within one year of completion, the owner-
m-
builder will have the ,burden of proving that he did not build or im-
prove
proveforpurposeofsale.).
❑ 1, as owner of the property, am exclusively contracting with-
GAS- EA. SYST - OVER 4.(EA.) 1.00
- - -
BUILDING USE
RES IND CON PB -Other.
❑' El El• El 'E]
INDUSTRIAL WAS EINTER. 20.00
licensed contractors to construct the project (Sec. 7044, Business
and Professions Code: The Contractor's License Law does not apply
to an owner of property who builds or improves thereon. and who
LAWN SPRINKLERS \-1 INC 5 V.B. 5.00
ASSESSORS PARCEL NO.
LAWN SPRINKLERS' OVER 5 (EA.) 1.00
contracts for such projects with a contractor(s) licensed pursuant to'
the Contractor's License Law.
SEWER -SANITARY -STORM` EA. 200ft/B.00
TRACT,NO.
PARCEL N0.
❑ I am' exempt under Sec. BAP.C. for this
reason
1/VATE,R HEATER W/VENT 4:00
Date Owner
WATER SYSTEM \ 4.00
ACC. DATE
ACC. FILE NO.
WORK ERS'COMPENSATION DECLARATION
WATER TREATING EQUIP. :-. �� 4.00
I hereby affirm that 1 have a certificate of consent to SCINnsure,
or a certifi ate of Workers' Compensation Insurance, or a certified
copy he e�.�80Jj>•
Policy �CddRf-7,
-
- \
ZONING
ENG. SITE NO.
\
N
- ❑ Certified o y i ereb IS/G'-��
D Cert' a th t tits ct' cion"
\Applican 1, �
FIRE SPRINK
y ry
❑ ❑
ENERGY T-29
y N
❑ ❑
MISC: REFER TO.OR6.
-
CERTIFICATE OF EXEMPTION FROM WORKERS'
PERMIT ISSUANCE 6.00
FLOOD ZONE
A.L.U.C.
COMPENSATION INSURANCE
(This section need not be completed if the permit is for one
Y ❑ N❑
Y ❑ N❑
PLG. CONTR.-.LIC. No.
PLG"'
TOTAL"
hundred dollars (S 100) or less.)
I certify that in the performance of the -work for which this per-
mit is issued, I shall not employ any person in any manner so as to
QTY. MECHANICAL PERMIT FEE
FEE SUMMARY
-
BUILDING
�% S
become subject to the Workers' Compensation Laws of California.
Date Applicant
NOTICE TO APPLICANT: If, after making this Certificate of Ex-
ALTER OR ADD TO MECH. 4.00
APPLIANCE 4.00
PLAN CHECK
FEE
////,� 75
�Y• -�
emption, you should become subject to the Workers' Compensation
provisions of the Labor Code, you-must"forthwith comply with
such provisions or this permit shall be deemed revoked.1R
HANDLING UNIT (TO 10=C.F.M.) 3.00
A HANDUNG UNIT (OVER 10=1C.F.M.) 5.00
SEISMIC FEE
�50
CONSTRUCTION LENDING----
I. hereby affirm that there is a construction lending agency for
the performance of the work for which this permit is issued (Seca
3097.Civ.C.).
EXH UST HOOD (WITH DUCT) 2.00
MICROFILM
HEAT 'I UNIT (TO 100,000 B.T.U.) 4.00
Lender's Name
Lender's Address -
HEATING IT (OVER 100,000 B.T.U.)7.50
ELECTRIC
I certify that I have read this application and state that the above
VENTILATIO FAN (SINGLE) 3.00
information is correct. I agree to comply with all city and county
ordinances and state laws relating to building construction, and
hereby authorize representatives of This city to enter upon the
above-mentioned property for inspection purposes.
PLUMBING
BOILER-COMP(3. or 100,000 B.T,U.) 4,00
BOILER -COMP (Over 0,000 BTU) SEE FEE SCH.
MECHANICAL
(We) agree to save, indemnify and keep .harmless the .City of-
Cupertino against liabilities, judgments, costs and, expenses which
may in any way accrue'- against said City in consequence of the
grantin Of p I 'l. -
Sina ure of App scant/ on tractor ITa e
MISC.-7 REFER TO ORD.
CONST. TAX'
_
PERMIT ISSUANCE 3.00
MECH. CONT. LIC. NO. MECH.
TOTAL
s 0.5 ,
TOTAL
0,'7 --
OFFICE COPY
., CITY OF CUPERT T V.O.
Building Division
V 3<�
PROJECT
CONTROL
ADDRESS 11,1W
(?4,4;PA-
PERMIT #
OWNER
PHONE
SAN. #
ADDRESS
BLDG. TYPE
REP.
PHONE
OCC. GROUP
ARCHITECT
PHONE
ADDRESS
REP.
PHONE
CONTRACTOR
_PHONE 4A1-3&ZZ ..VAL.
$
ADDRESS
STRUCT.PLAN CK
REP.
PHONE
BLDG.PLAN.CK
PLAN CHECK HOURS
PERMIT FEE
CAP FEE
CONST. TAX
ENERGY FEE
TOTAL FEES
DATE C.
DATE RET.
BLDG. DEPT.
ENG. DEPT.
PLAN. DEPT.
STRUCT. ENG.
CENTRAL FIRE DIST.
-HEALTH DEPT.
-SAN. DIST.
-ENERGY
-HANDICAPPED
r�
C.1TY OF CL'PEIRTINO INSPECTIOV RECORD (Office Copy)
1 3183 11121 Clarkston Ave.
1'1'P1fIT PIO `' 1NITARY DIST NO 1 OT NO AM)1'USti
13uildinr 2-23-83
1;].ectrica1 2-23-8_
Plumhin�
Mcchan ical
Temp. Gas/Elect.
Solar
Tire Sprinkler
Sign
1lisc.
Storage Area Roberts
PROJECT OWNER JOB SITE PHONE NO.
PER11IT ISSUED nate ELECTRICAL
_ nate I T.nsp.
FINAL INSPECTIONS
Date Insp.
s
F].e.Ctri_c -
Pltimbin ,
Mechanical
Solar
Pool
Gradin
Planning
Fire Dept.
Health th De t.
Building �-(6
Other
BUILDING
Date
Pad Certification
Foundation-8-�
Pre-Gunite
Insp.
Slab -Membrane
Bond Beam
Underfloor Girders
Floor Steel
Tledowns
Diaphrams
Seismic Bracing
halls-Pancls
frame
1.1 t h
]Wallboards n /Ext.
Firewalls
Other
Not Approved
Power Pole
Underground
Rough Wiring
1Tal 1S
Ceiling;
Fixtures Int/Ext
ilotors
Grounding
Temp. Power
Other _
Not Approved
PLUMBING
Date
Backflow
lrtsp.
Underground
Underfloor
Partial Rough
Rough Complete
Solar Roti h
Water & Insulation
Main Drain
R/of/S Drain
_
Gas
Other
Not Approved
HECHAN ICAL
Date
Underfloor S.M.
Insp.
Ducts & Insulation
Fire Dampers
Fireplace
Grease Duct & flood
One Hour Shaft
Condensate Drain
Equipment Anchorage
Flues & Comb. Air
Other
Not Approved
BUILDING
ELECTRICAL
Quality Assurance Services
Materials Consulting
Testing Engineers, Incorporated
1= R 1 A 1q R'1
LABORATORY NUMBER E0174
File: "B"
TEI Project Number: 05636
BAR790
J. C: Barry Supply & Manufacturer
355 Mc Glincey Lane
Campbell, California 95008
Attention: Mr. Jim Barry
DATE. July 9, 1982
BLDG. CIPOFrICUPERTINO ON DEPARTMENT
SUBJECT: Load test one 4' x 8' and one 4' x 4' skylight
Gentlemen:
As requested, the two skylights submitted to our laboratory June 30, 1982 were
loaded to an average of 105 pounds per square foot. The dome configuration of
the skylights made uniform distribution of the loads difficult. For both the
4''x 4' x 1/8" thick and 4' x 8' x 3/16" thick skylights a uniformly distributed
load of 100 psf was applied. Additional weight was distributed along the Tongi-
tudinal axis of the 4' x 8' sample and over the center of the. 4' x 4 sample
to arrive at the specified average load of 105 psf. The skylights were placed
directly on a concrete slab for loading. No support frame was provided.
No permanent deformation of the 4' x 4' skylight occurred. The frame of the
larger skylight began to bend or "squash" at 50 psf. At 100 psf the frame
had flattened against the concrete slab at the midpoints of the four sides.
As the,'remaining load was applied five of the screws attaching the upper frame
to the lower frame broke. or pulled out.
This was a result of the severe distortion. Had a frame been provided to support
the skylight, the damage may not have occurred.
If you should have any questions please don't hesitate to contact us.
Very truly yours,
TESTING ENGINEERS, INCORPORATED
r�
Reviewed
rego u
Staff ,Engineer
401 Aldo Avenue, Santa Clara, California 95050 • 408-.988.8888
SAN FRANCISCO • OAKLAND • DIABLO VALLEY • REDDING • SACRAMENTO • STOCKTON • MONTEREY
1365 VANDER WAY SAN JOSE, CALIFORNIA 95112 (408) 297-6969
Ditz Crane
2295 De La Cruz Boulevard
Santa Clara, California
Attention: Mr. Charles Discoe
Subject: Geotechnical Investigation
Lands of Cali
Cupertino, California
Gentlemen:
October 20, 1971
Project 1353
This report completes our geotechnical investigation for the proposed residen-
tial development to be constructed on the west side of Bubb Road, near
Columbus Avenue in Cupertino, California. The development area consists
of twb separate parcels of 5.3 and 17.1 acres which will be subdivided into
93 lots as shown on the Site Plan, opposite page. One and two-story, single
family residences with light wood -frame construction are proposed for con-
struction.
This investigation was directed toward a determination of pertinent geo-
technical factors relative to the proposed development and culminates in
this report containing our recommendations relative to site grading, struc-
tural pavement design and structure foundation parameters. A total of thirteen
(13) exploration holes were drilled at the site and undisturbed samples re-
covered for laboratory analysis. Representative bulk surface samples were
also obtained for compaction and "R" Value testing, in order to provide in-
formation for control of both site grading and pavement section design. The
logs of exploration drill holes together with laboratory test results are
appended hereto.
SITE CONDITIONS
Northern Parcel - with a gross area of 21.0 acres, a small parcel of 3.9 acres
near the western end of this oblong parcel is to be excluded from development,
leaving a net development area of 17.1 acres. The site slopes gently to the
northeast, with a total relief of approximately thirty-five (35) feet. This
parcel is presently in agricultural production as a prune orchard and the sur-
face has been regularly disced, resulting in a loosened soil condition in the
upper six (6) to eight (8) inches. There were no structures encountered within
the area proposed for development. Near surface soils range from sandy CLAYS
and SILTS of low plasticity to clayey or silty SANDS. These are underlain by
Project 1353
October 20, 1971
-2-
randomly interbedded CLAYS of low plasticity, silty and clayey SANDS and
clayey GRAVELS in layers that randomly pinch and swell in thickness and
in some cases, die out altogether. This random stratification is typical
of alluvial deposits within this area of the Santa Clara Valley. One wet
spot associated with drainage from an existing house in the excluded area
exists near the western end of the east -west portion of the proposed
Havelock Avenue. However, there was no groundwater encountered in.any of
the exploration holes to the maximum depth explored of twenty (20) feet.
Southern Parcel - A 2.3 acre exception within the west -central portion.of
this site results in a net area for development of 5.3 acres. The ground
surface has a similar but more moderate slope to the northeast, and this
smaller site also has a maximum relief of approximately thirty-five (35)
feet. With the exception of a driveway from Bubb Road to an existing house
within the excluded portion, this site is also free of existing structures
and is in agricultural production as a prune orchard. Surface discing has
resulted in a loosened condition within the upper six (6) to eight (8) inches.
Surface soils consist of clayey and silty SANDS, and are underlain by lenses
of variable thickness consisting of sandy or silty CLAYS and clayey GRAVEL.
Groundwater was not encountered in any,of the exploration holes to the maximum
depth explored of fifteen (15) feet. However, several wet spots adjacent to
the eastern end of Flintshire Street were noted, and are probably associated
with uncontrolled surface runoff from the higher developed areas to the west.
RECOMMENDATIONS
Grading
Moderate site grading will be required in the creation of level building pad
areas, preparation of pavement subgrade, and the provision of adequate surface
drainage gradients away from foundation and peripheral slab areas. We antici-
pate that grading operations will be directed toward a balance of cut and fill
within each development area.
The initial grading operations should be directed towards the removal of
approximately three (3) inches of existing surface material, within the surface
of all proposed building areas and all areas to receive fill. This stripped
material may be stockpiled for later'use in landscaping or adequately blended
with fill materials in the creation of site'fills provided that this procedure
receives the prior approval of a representative of this office. If mass grading
is performed before the onset of winter rains or after the normal discing has
been carried out, the stripping requirement may be waived, provided that this
procedure is approved by the soil engineer. Although surface and subsurface
structures were not encountered within the property boundaries during the field
investigation, buried structures may be encountered and contingent provisions
should be made within project specifications for their removal. Any sanitary
or storm drain outlets encountered during the earthwork construction should be
properly intercepted and turned into the appropriate sanitary or storm facility
planned for this project. All depressions or loosening of the soil resulting
from tree or structure removal should be backfilled with suitable on-site
material, moisture conditioned as necessary and compacted with appropriate com-
paction equipment. Backfill to restore grade within these areas as well as
T E R R A T E C H
Project 1353
October 20, 1971
-3-
within all other fill areas should be compacted with a relative compaction of
at least 90 per cent of the maximum dry density obtainable by ASTM Test
Designation D1557-70. For purposes of quantity balance in the site mass
grading operations, we recommend the assumption of shrinkage factory of 20
and 10 per cent 'for the upper twelve (12) inches and deeper site soils,
respectively.
All earthwork should be inspected and tested by a representative of this firm.
Recommended "Guide Earthwork Specifications" are appended hereto.
Foundations
Support for the proposed one and two-story, split-level, wood -frame buildings
may be provided through continuous perimeter footings. These shallow spread
footings should have a minimum width of twelve (12).inches, should be founded
at a minimum depth of twelve (12) inches below rough pad grade and may be de-
signed for a maximum allowable bearing pressure of 3,000 pounds per square
foot for the combined effect of dead plus live loading. All continuous footings
should be reinforced by a minimum of at least two No. 4 reinforcing bars, one
each at the top and bottom of the footing.
Any loose subgrade soil within the footing trenches should be densified prior
to the placement of the concrete footing material. If any shrinkage cracks
develop prior to the placement of the concrete, they should be effectively
sealed by intermittent sprinkling prior to concrete placement.
Slabs -On -Grade
Concrete slabs -on -grade are anticipated for utilization within garage, driveway,
and perimeter sidewalk areas and may comprise the ground floor slabs beneath
some living areas. Where the slabs underlie the proposed living areas, they
should be constructed on a minimum of four (4) inches of a granular, free -
draining sand -gravel material or pea gravel so as to provide an effective
capillary break. In addition, an intervening moisture barrier, consisting of
plastic membrane or .similar material should be placed between the sand -gravel
material and the overlying floor slab. Wire mesh reinforcement is recommended
within slabs underlying living areas.
In garage, diiveway and sidewalk areas where surface moisture is free to
dissipate by evaporation, the slab may be constructed directly on subgrade and
the moisture barrier may be eliminated. The requirement for reinforcing may
also be waived in garage slab areas provided that a premolded construction
joint or one (1) inch by four (4) inch redwood screed is provided to effectively
separate the slab into at least two (2) equal parts.
In all cases, the subgrade of all areas to receive concrete slabs -on -grade
should be proof -rolled to provide a firm media for slab support. Subgrades
beneath concrete floor slabs should be lightly sprinkled prior to the installa-
tion of either the overlying concrete or the waterproof membrane, to bring the
soil moisture condition as near as possible to the post -construction condition.
T E R R A T E C H
Project 1353
October 20, 1971
-4-
Pavement
"R" Value parameters to aid in evaluation of subgrade soils and determination
of recommended structural pavement design sections were developed on two (2)
representative samples of the near surface soils encountered on these sites.
The higher "R" Value would apply only to those areas where subgrade materials
exhibit appreciably higher granular soil content in their gradation, a con-
dition which should be evaluated at the time of subgrade preparation.
Alternative pavement designs, as provided, include the conventional asphaltic
concrete surface course overlying aggregate base material as well as a full -
depth, "Deep Strength" pavement section. The conventional design has been
prepared in accordance with the State of California, Division of Highways,
Department of Public Works Planning Manual Part VII, Section 7-6.04 (Design
Procedures for Flexible Pavements). The full depth, "deep strength" pavement
design follows the procedures outlined within the Asphalt Institute Manual
MS -1, Eighth Edition. Although pavement structures for this particular pro-
ject will be constructed on moderately strong subgrade materials, the advantages
of the full -depth, "deep strength" design are worthy of consideration. These
factors include a significant decrease in excavation requirements, together
with the fact that elimination of the baserock section under the asphaltic
concrete surfacing minimizes the possibility of the lateral transmission of
groundwaters beneath the pavement surfaces, a factor which often contributes
to the ultimate failure of pavement sections.
"R" Value results were 22 and 61 for the clayey SAND and more granular soils,
respectively. In line with our discussion with the traffic department of
the Cupertino City Engineers Office, the traffic index for Columbus Avenue is
5.0 and that for all other streets proposed for this development is 4.5. Bubb
Road is fully developed including curb, gutter and sidewalk fronting on these
two sites, and need not be considered as part of this improvement. Recommended
pavement sections based on the minimum "R" Value and appropriate traffic index
are presented in the following table.
Basis & Area
RECOMMENDED PAVEMENT SECTIONS
SECTION THICKNESS (Inches)
Conventional Design Full Depth "Deep Strength"
Class II
Class II Type B
Total
Class II Type B
Aggregate
Asphaltic
Section
Asphaltic
Base
Concrete
Thickness
Concrete
Columbus Ave. 8.0
2.5
10.5
6.0
All Other Sts. 7.0
2.5
9.5
5.0
Site Drainaqe
The naturally sloping topography of both sites will contribute to effective
drainage control. However, we anticipate that development plans will result in
T E R R A T E C H
Project 1353
October 20, 1971
=5 -
relatively flat building pad areas, and individual site drainage will therefore
become a development requirement. Hence, it is imperative that site grading
be developed such that surface runoff is directed away from foundation and slab
perimeters and towards suitable discharge facilities. Landscaping should be
designed so as not to create impediments to site drainage.
CYANC`T.T1ST(W S
From a soil and foundation engineering standpoint; it is our opinion that the
site is suitable for the proposed development. Foundation soils are relatively
strong and incompressible and are expected to be capable of providing satis-
factory support for the proposed residential structures. All site earthwork
should be performed under the inspection of a representative of this firm and
in accordance with the appended "Guide Earthwork Specifications".
We believe our subsurface exploration at the site provides sufficient informa-
tion from which reasonable conclusions can be drawn. However, alluvial soils
of the type encountered at these sites tend to be somewhat heterogeneous and
some deviations in consistency and material types may be encountered. Any signi-
ficant variations from conditions described herein which are encountered during
construction and which would materially effect the performance of the proposed
development should be immediately brought to our attention so that supplemental
recommendations may be provided to meet the changed conditions.
Please provide us with one (1) copy of the final grading plans and the founda-
tion details prior to their release as part of the contract documents. We
will review them as necessary and provide our comments as required.
Very truly yours,
QEF$$/Q
TERRATECH, IN Q Nq1
. O
' F
Kenneth L.: bVe aen No. 17487
RE 17487
CIVIVJ
cc: MacKay arid., $oTl►ps=;i+Fr".ob Reese
T E R R A T E C H
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE NO. 1
DATE .10/4/71 HOLE DIA. 6" DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 381 DEPTH TO GROUNDWATER INITIAL FINAL LOGGED BY KIM
�L CI 11 Co �i e A �
rS O O/ 'l� �/( OQ�O �%�C'f OPL
p /
.c. pis �P F•� y'L
/A`��.A
Oti
Silty, sandy CLAY
Brown
Dry
Soft
CLS
1
Moist
Firm
x
to
2
x
Stiff
X
8
3.0
0.6
3
V.Stiff
-4-
x
5
x
X
21
3.5
1.0
6
%
Silty CLAY
Brown
Moist
Hard
CL
8
9
-10-x
11
X
X
37
4.5
1.0
-
12
1 3
Gravelly, silty CLAY
Brown
Moist
Hard
CLG
-14-
15
Cobbles
-16-
16-1718Bottom
Clayey, gravelly SAND
Lt. Brn
Moist
Dense
SWC
-17-
-18-
1g
Bottomof Hole - 20.0'
No Water
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT, Lands of Cali HOLE NO. 2
DATE 10/4/71 HOLE. DIA. 6" DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 377 DEPTH TO GROUNDWATER INITIAL --- . FINAL --- LOGGED BY KIN!
CL ('O'li c'p 'ti 9 O
p�s� ,�`�S `���(0,iSc�,�$O�c�`OQ�
ioT/ GQ� Teti to ,or
•
C,
Oti
Clayey, sandy SILT
Lt. Brn
DrV
Soft
MLS
S1.Mois
1
2
X
X
Silty SAND
Yel. Brn
S1.Mois
V.Dense
SWN
(porous in upper crust)
3
X
50+
4.5
Sandy GRAVEL
Brown
S1.Mois
V.Dense
GW
-4-
Hard Drilling
5
6
7
-
-
8
9
10.
Bottom of Hole 10.0'
No Water Encountered
-11-
117181g
17-
-18-
-191
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH"
EXPLORATION DRILL HOLE ;LOG
PROJECT Lands of Cali HOLE NO. 3
DATE 10/4/71 HOLE DIA. 6DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 365 DEPTH TO GROUNDWATER INITIAL --- FINAL --- LOGGED BY KIM
(10,A
F
/Oti F ��,� �• y C9�/T F� �rF
,�
r
Silty, clayey SAND
Lt. Brn
Dry
Loose
SWC
1
S1.Mois
.Dense
X
2
x
X
32
4.5
Gravelly, clayey SAND
Brown
Sl-Moisl
Dense
SWC
-3
-4
-5
V.Dense
X
-6
x
X
58
4.5--
.57Bottom
7-
10
Bottomof Hole - 10.0'
No Water Encountered
11
12
15
-17
18
1g
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE NO. 4
DATE 10/4/71 HOLE DIA. rO" DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 376 DEPTH TO GROUNDWATER INITIAL --- FINAL --- LOGGED BY KIM
OO ~�is �i`
O�s�~���F O�•9
7,0 I' Otn OST
Gp �� 1-0 10�
�O O� q� F
Sandy SILT
Lt. Brn
Dry
Soft
MLS
1
S1.Moist
Hard
X
2
x
X
40
4.5
3
- 4
X
Clayey SAND
Yel.Brn
Moist
Dense
SWC
-5
x
X
35
4.5-
.56789Gravelly
6-
7-
8-
-9-
10
X
GravellySAND
Yel.Brn
Moist
V.Dense
SW,
11
X
50+
4.5
-
12
-14
'Moist
Silty CLAY
Lt. Brn
Hard
CL
15
x
-16
X
50+
Bottom of Hole --16.0'
No Water Encountered
-17
18
LA
1g
-
SOIL, TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE NO. 5
DATE , 10/4/71 HOLE: D)A. 6" DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 364 DEPTH TO GROUNDWATER INITIAL -- FINAL ---- LOGGED BY KIM
(� 0' 4- CIO '1y �� J'
`/Al S �O
A F
/O~ F ~cam �• y c9��T �� ��F
c.
Silty SAND
Lt.Brn
Dry
Loose
SWN
1
Sl.Moisl
Dense
X
2
x
X
47
4.5
3
Gravelly SAND
Brown
S1.Mois
V.Dense
SW
-4
(Subrounded Particles)-
-5 -
Hard Drilling
-6-
-7-
-7Sandy
9-
Sandy CLAY
Brown
Moist
Hard
CL
_10-
11
x
x
X
50+
4.5
Clayey SAND
Yel.Brn
Moist
V.Dense
SWC
12
15
Bottom of Hole -.15.0'
No Water Encountered
-16
'
17
18
19
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE NO.. 6
DATE 10/4/71 HOLE .DIA. 61' DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 360 DEPTH TO GROUNDWATER INITIAL FINAL --- LOGGED BY KIM
A
OC-tO00`po, �Z"0� F`,���,� r0�`
,OP F ti0j-
SandySILT
Lt. Brn
Dry
Soft
MLS
Firm
1
S1.Mois
2
X
X
Silty SAND
Brown
S1.Moist
Dense
SWN
X
37
4.
3
4
5
X
Clayey SAND
Brown
Moist
Dense
SWC
6
x
X
43
4.5
8
Sandy CLAY
Brown
Moist
V.Stiff
CLS
9
10
'`
11
17
18
-19
Bottom of Hole - 20.0'
No Water Encountered
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
.PROJECT Lands of Cali HOLE NO. 7
DATE 10/4/71 HOLE DIA. 6" DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 355 DEPTH TO GROUNDWATER INITIAL FINAL LOGGED BY KLM
7
0 O`L 0�
C�j, 1.
'QjA sr
L T s .p
Q� Cny 10 0,� F .
Op C,�9l/ F� FA
r
Silty SAND
Lt.Brn
Dry
Loose`
SWN
1
S1.Mois
.Dense
X
2
X
X
11
4.5
Dense
_ 3
-4-
-5
-5-
X
x
6
X
X
50+
Gravelly SAND
Brown
Moist
V.Dense
SW
-7-
-8-
89Bottom
-9-
10
Bottom of Hole - 10.0'
No Water Encountered
-11-
-12
-16
17
18
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE- NO. 8
DATE 10/4/7.1 HOLE DIA. 6" DRILL RIG Cont. Flight SAMPLER Check Hole
HOLE ELEV 352 DEPTH TO GROUNDWATER INITIAL --- FINAL --- LOGGED BY KIM
CO �Oi C0'L `l �i0 ��O A�'SOP
SC'p/A G, t'
SSG �..s� l �yS c�`��,���
OSA
OC,
04,
Sandy SILT
Lt.Brn
Dry
Soft
MLS
1
Sl.Moist
Stiff
-2
3
Silty, gravelly -SAND
Lt.Brn
Sl.Moist
Dense
SWN
-4
-5
6
Silty, clayey SAND
Brown
Moist
Dense
SWC
-
8
9
-10
Bottom of Hole - 10.0'
-No Water Encountered
11
215SO-12-
_15-
SOIL
IL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL - HOLE LOG
PROJECT Lands of Cali HOLE NO. 9
DATE 10/4/71 HOLE DIA. 6" DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 350 DEPTH TO GROUNDWATER INITIAL - FINAL --- LOGGED BY KIM
C A �` A �
O� QST 1`�'S �'( O�Sc<`'O,Q9
Ov
9
Sandy SILT
Lt.Brn
Dry
Soft
MLS
1
S1.Mois
V.Stiff
X
2
X
X
39
Silty SAND
Lt.Brn
S1.Mois
Dense
SWN
(Slightly Porous)
3
4
5
X
Sandy CLAY
Brown
Moist
Hard
CLS
6
X
X
52
8
9
10
-
11
12
Silty CLAY
Brown
Moist
Stiff
'CL
-14-
15
Clayey GRAVEL
Brown
Moist
V.Dense
GWC
Bottom of Hole - :15.0
No Water Encountered
-16
17
18
�9
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE NO. 10
DATE 10/4/71 HOLE DIA. .61' DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 345 DEPTH TO GROUNDWATER INITIAL FINAL . LOGGED BY KIM
OCIO / ti lb/�QQ OIp
C`74 L9�
O~ 0)-
v�
Sandy SILT
Lt. Brn
Dry
Soft
MLS
Firm
S1.Mois
V.Stiff
X
-2
X
X
23
4.5--
.55Clayey
5-
X
ClayeySAND
Brown
Sl.Moisi.V.Dense
SWC
6
X
50+
7
8-
Silty, gravelly SAND
Brown
S1.Mois
V.Dense
SWN
9 -
9Bottom
10
Bottom of Hole - 10.0'
No Water Encountered
11-
112-13SOIL
-12-
-13-
SOILTYPE CLASSIFICATION, BASED ON BRITISH SUGGESTED REVISIONS. TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE NO. 11
DATE 10/4/71 HOLE DIA. 61' DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 393 DEPTH TO GROUNDWATER INITIAL FINAL LOGGED BY KIM
A>
Op
V 'P
Clayey, silty SAND
Lt.Brn
Dry
Loose
SWC
1
Brown
S1Moist
Dense
X
-2
x
X
34
4.5
3
-4
5
V.Dense
X
6
X
57
4.5
.
8
(Hard Drilling)
9-
-10-
x
x
11
X
X
56
4.0
12
Clayey, sandy GRAVEL
Brown
Moist
V.Dense
GWC
°.
13
15
Bottom of Hole -'15.01
No Water Encountered
-16
17-
-18-
191 19
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands.of Cali HOLE NO. 12
DATE 10/4/71 HOLE DIA. 6„ DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 367 DEPTH TO GROUNDWATER INITIAL FINAL LOGGED BY KLM
O 4_ 00
O O�L
%(�
'Qip�/ Cip� Sl�ti l�A� (np�y
CC
O~
04 -
Silty SAND
Lt.Brn
Dry
Loose
SWN
Sl -Moist
Dense
X
2
x
X
39
4.5--
.5345Clayey
3-
-4-
5-
X
ClayeySAND
Brown
Moist
V.Dense
SWC
6
x
X
61
4.5
7
-
8
g
Sandy CLAY
Brown
Moist
Hard
CLS
10
x
11
x
X
54
Clayey GRAVEL
Brown
Moist
V.Dense
GWC
5 -
Bottom of Hole - '1"5.0:'
No Water Encountered
16
7-
-18-
1819SOIL
-19 -
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM '
PROJECT 1353 TERRATECH
EXPLORATION DRILL HOLE LOG
PROJECT Lands of Cali HOLE 'NO. 13
DATE 10/4/71 .{OLE DIA. 6" DRILL RIG Cont. Flight SAMPLER Mod. Calif.
HOLE ELEV 383 DEPTH TO GROUNDWATER INITIAL --- FINAL --- LOGGED BY KLM
119<,A j.
�QS�G Ilk C0�4,o
�.L �F
�� q o
04' 0j- FBF`
AN
Clayey SAND
Lt.Brn
Dry
Loose
SWC
1
S1.Mois
Dense
(Slightly Porous in
X
Upper 18")
2
x
X
36
4.5-
.5345
3-
-4-
5-
6
x
X
Silty CLAY
Lt.Brn
Moist
Hard
CL
X
33
4.5
7
8
g
Sandy CLAY
Brown
Moist
Hard
CLS
10
x
11
X
x
50+
-12-
-1
Clayey GRAVEL
Brown
Moist
V.Dense
GWC
-14-
15
Bottom of Hole - 15.0'
No Water Encountered
-16-
6171g
17-
-191
SOIL TYPE CLASSIFICATION BASED ON BRITISH SUGGESTED REVISIONS TO UNIFIED SOILS
CLASSIFICATION SYSTEM
PROJECT 1353 TERRATECH
SUMMARY
OF LABORATORY
TEST DATA
- -----------------------------------------------------------------
HOLE
DEPTH
NATURAL
NATURAL
UNCONFINED
NO.
WATER
DRY
SHEAR
CONTENT
DENSITY
STRENGTH
------------------
(feet)
-----------------------------------------------
M
(pcf)
(psf)
-
1
2.0
14
113•
2120
5.0
17
114
3240
---------------------------=--------------------------------------------
11.0
20
109
3790
2
----------------------------------------------------
2.0
11
119
-------------------
----
3
2.0
16
7
113
9560
6.0
11
122
5170
------------------------------------------------------------------------
4
2.0
15
114
----
5.0
13
118
----
10.5
8
122
----
-----------------------------------
15.5
11
-------------------------------------
122
----
----------------------------------------------------------------------------
5
5
2.0,
11
116
----
------------------------------------------------------------------------
10.5
16
114
----
6
2.0
9
114
----
------------------------------------------------------------------------
6.0
18
113
----
7
2.0
10 -
112
----
------------------------------------------------------------------------
6.0
15
117
----
9
2.0
6
107
----
------------------------------------------------------------------------
6.0
16
116
6130
10
2.0
6
107
----
5.5
10
118
----
---Project
ProjectNo. 1353
TERRATECH
Page 1 of 2
SU101ARY OF LABORATORY TEST DATA
HOLE
Project
DEPTH
NATURAL
NATURAL
UNCONFINED
NO.
WATER
DRY
SHEAR
CONTENT
DENSITY
STRENGTH
-----------------------------------------------------------------
(feet)
M
(pcf) _
(psf)
11
2.0
12
120
6250
5.5
14
120
----
11.0
13
124
----
-------------------------------------------------------------------------
12
2.0
8
106
----
6.0
17
114
5480
11.0
16
116
----
-------------------------------------------------------------------------
13
2.0
15
114
7620
6.0
21
108
4700
11.0
14
123
---
----
Project No. 1353 TERRATECH Page 2 of 2
SAMPLE NO. 10 DEPTH (FT) p - 1
LOCATION
SAMPLE DESCRIPTION - Brown, sandy SILT
EXUDATION PRESSURE (psi)
800 100 600 500 400 300 200 100 0100
2 0
90
1.8
I
80
1.6
10
W 1.4
W
60
W 1.2
ME
O
J
m
Q
W
�
50 c
H 1.0
m
�
N
N
40
z 0.8
Y
U
S
F-
30
L" 0.6
C
O
U
20
0.4
10
0.2
0
D
0. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
COVER THICKNESS BY EXPANSION PRESSURE (FEET)
SPECIMEN NO.
A
B
C
EXUDATION PRESSURE (psi)
170
330
640
EXPANSION DIAL (0.0001 inch)
—__
—__
___
EXPANSION PRESSURE (psf)
62
98
203
RESISTANCE VALUE "R"
30
66
77
MOISTURE CONTENT -AT TEST (X)
13.3
11.5
9.8
DRY DENSITY AT TEST (PC[)
115.5
118.3
118.8
"R" -VALUE AT 300 psi EXUDATION PRESSURE = 61
LANDS OF CALI
CUPERTINO, CALIFORNIA
"R" VALUE TEST RESULTS
PROJECT NO, TEST N0. DRAWING N0.
1353
SAMPLE NO. 11
1 DEPTH (FT) 0 - 5
LOCATION
SAMPLE DESCRIPTION Brown, clayey SAND with gravel
EXUDATION PRESSURE (psi)
.0 800 700 600 500 400 300 200 100 0100
2
90
1.8
80
1.6
70
W 1.4
W
W
Q
W
60
W 1.2
0
m
Q
H
w
�
J
50
1.0
m
d.
N
N
ui
40
z 0.8
C
U
2
F
30
W 0.6
0
U
20
0.4
10
0.2
0
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
COVER THICKNESS BY EXPANSION PRESSURE (FEET) -
4
SPECIMEN NO. - .
A
B
C
EXUDATION PRESSURE (psi):` _ , _ _
160
250.
380
EXPANSION OIAL (0.0001 inch)
EXPANSION PRESSURE (psl)
nil
20
56
RESISTANCE VALUE °R"
10
17
30
MOISTURE CONTENT AT TEST (%)
16.3
14.9
13.6
DRY DENSITY AT TEST (Pcf')
113.3
116.4
120.1
nR"-VALUE AT 300 psi EXUDATION PRESSURE = 22
IIRII VALUE TEST RESULTS
LANDS OF CALI
PROJECT NO. TEST N0. 0RANIN6 N0.
CUPERTINO, CALIFORNIA
1353
130
w
U
CL
}
Z 125
w
0
}
0
120
115
130
COMPACTION TEST
0 5 10 15 2(
MOISTURE CONTENT — %
110 '
0
PROJECT NO. 135
•
• j
■■■■■
■■NEM
5 10 15 20
MOISTURE CONTENT — %
SAMPLE NO.
1,
SAMPLE DEPTH
0 - 1 Ft.
SAMPLE DESCRIPTION
Brown, sandy
CLAY
SPECIFIC GRAVITY
2.70 (est.)
TEST DESIGNATION
ASTM D1557-70
MAXIMUM DRY
DENSITY '( PCf)
128.0
OPTIMUM MOISTURE
CONTENT, %
9.7
SAMPLE NO.
10
SAMPLE DEPTH
0 - 1 Ft.
SAMPLE DESCRIPTION
Brown, sandy
Silt
-SPECIFIC GRAVITY
___ __2.-70 (est. )
_TEST DESIGNATION
ASTM D1557-70
MAXIMUM.DRY
DENSITY (PCf)
124.0
OPTIMUM MOISTURE
CONTENT, %
11.0
130
w
v
CL
}
z 125
W
0
}
120
115
COMPACTION TEST
0 5 10 15 2C
MOISTURE CONTENT - %
PROJECT NO. 1353
■■.■■
mom■■
MOISTURE CONTENT
SAMPLE NO.
11
SAMPLE DEPTH
0 - 5 Ft.
SAMPLE DESCRIPTION
Brown, clayey
SAND with
gravel
SPECIFIC GRAVITY
2.70 (est.)
TEST DESIGNATION
ASTM D1557-70
MAXIMUM DRY
DENSITY '( PCf)
128.0
OPTIMUM MOISTURE
CONTENT, %
10.9
SAMPLE NO. -
SAMPLE DEPTH
SAMPLE DESCRIPTION
SPECIFIC GRAVITY
TEST DESIGNATION
MAXIMUM DRY
DENSITY (PCf)
OPTIMUM MOISTURE
CONTENT, %
PLASTICITY CHART
so
HOLE
NO
DEPTH
LIQUID
LIMIT
('. )
PLASTICITY
INDEX
CV
CE
50
1:5
30
16°
pis
C H
�� p
M E
MV
40
CI
x
Uj
CL
Y 30
H
001,
---
N
-
L
so
HOLE
NO
DEPTH
LIQUID
LIMIT
('. )
PLASTICITY
INDEX
CV
CE
50
1:5
30
16°
pis
40
x
Uj
Y 30
001,
N
CL 20
10
1
MI
a
M
0
0 10 20
30
40 50
60
10 80
90 100
LIQUID LIMIT
('/.)
PLASTICITY
DATA
* Soil Type Classification Based On British Suggested Revisions To Unified
.Soils
Classification
System
Project
1353
KEY
SYMBOL
HOLE
NO
DEPTH
LIQUID
LIMIT
('. )
PLASTICITY
INDEX
UNIFIED
SOIL
CLASSI-
FICATION
SYMBOL
1:5
30
16°
pis
SAND EQUIVALENT TEST RESULTS
TRIAL 1 TRIAL 2 TRIAL 3
3.2 = 28 3.'1 -- 27 3-2 = 28
11.4 11.5 11.4
Average of three (3) readings: 28
Project 1353B Page 1 of 1
T E R R A T E C H
SAMPLE NO. 1 DEPTH (FT) Unknown LOCATION Sampled by Others
SAMPLE DESCRIPTION Stevens Creek Quarry
EXUDATION PRESSURE (psi)
2.0
1.8
1.6
LU 1.4
2
W
f 1.2
O
J
m
Q
ti 1.0
m
LUN
N
z 0.8
Y
U
S
H
W 0.6
Cm
0
U
0.4
0.2
0
I 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
COVER THICKNESS BY EXPANSION PRESSURE (FEET)
SPECIMEN NO. A
EXUDATION PRESSURE (psi) 110
EXPANSION DIAL (0.0001 inch) — --
EXPANSION PRESSURE (psf) -- —
RESISTANCE VALUE "R" 6 4
MOISTURE CONTENT AT TEST M 11.4
DRY DENSITY AT TEST (pcf) 130.1
'IR" -VALUE AT. 300 psi EXUDATION PRESSURE = 75
MONTEBELLO DEVELOPMENT
Cupertino, California
IUU
100
90
80
70
60
50 a
1
s
40
30
20
10
0
B C
320 500
76 78
10.6 9.8
131.0 131.3
IIRII VALUE TEST RESULTS
PROJECT NO. TEST NO. DRAWING NO.
353B --- Fig. 2
^
�
�
�
�
�
�
SAND EQUIVALENT TEST RESULTS
TRIAL lTDI&L 2
-------- --------
3.l = -28 3.1 — 23
10.4 10.9
�
`
^ `
Average of tiiree (3) zeadiuga;}D
Project 1353B
TeenATsc* '
�
Page l of l
SAMPLE NO. ' 1
DEPTH (FT) Unknown LOCATION Sampled by Others
SAMPLE DESCRIPTION Stevens Creek Quarry
EXUDATION PRESSURE (Psi)
800 700 600 500 400 300 200 100 0100
2.0
90
1.8
I
80
1.6
I
70
w 1.4
w
60
1.2
0
J
CO.�
a
W
50
H 1.0
Y
m
1
N
N
'
40
0.8
U
2
r
W
30
0.6
0
U
20
0.4
z
10
0.2
z
z
I -
0
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
COVER THICKNESS 8Y EXPANSION PRESSURE (FEET)
SPECIMEN NO.
A
B
C
EXUDATION PRESSURE (Psi)
270
410
780
EXPANSION DIAL (0.0001 inch)
---
---
--- '
EXPANSION PRESSURE (Ps()
--- .
---
---
RESISTANCE VALUE °R"
72
81
85
MOISTURE CONTENT AT TEST (X)
11.8
11.3
10.6
DRY DENSITY AT TEST (Pcf)
131.8
132.2
132.0
"R" -VALUE AT 300 Psi EXUDATION PRESSURE _
MONTEBELL'O DEVELOPMENT
Cupertino, California
IIRIJ V A L U E T E S T R E S U L T S
PROJECT NO. TEST N0. DRAWING N0.
1353B ---