Loading...
3600TO FILL IN INFORMATION WITHIN RED LINES.- USE BALI._ POINT PEN UNLY ;.APPLICANT ik -� BUILDING PROJECT I DEN*IC P MIT NUMBER APPLICATION & Pft 9UILUING O O ADDRESS � ' g �` � BUILDING -ELECTRICAL- PLUMBING -MECHANICAL �- -•� OWNER'S ,A• 1O. i ' _ NAME V PLAN CHECK VALIDATION r VY\Y� C�.I 5 = QTY. ELECTRIC PERMIT FEE vNoPF 32£3.823 ,Sa 322 la CONTRACTOR'S CONTRACTOR'S OUTLETS - SWITCHES - RECEP 5.00/1.00 NAME LIC. NO. LIGHTING FIXTURES 5.00/1.00 PPLIANCES- RESIDENTIAL AS .4.00 ADDRESS ADDRES PHONE PANELS 5.00 DATE OF APPLICATION ARCHITECTSIGNS 6.00 - PLAN CHECK FEE P.C. NO. OR - ENGINEER LIC. No. SIGNS TRANS. 3.00 ARCH. OR ENG. - SPECIAL CIRCUIT • 5.00 PERMIT VALIDATION ADDRESS zip EMP. METER OR POLE INS. 15.00 zip APPLICANT'S Y�7 „ MOTORS SEE FEE SCH. . 6� SS CNu12U-1 Q- i' S SERVICE CHANGE 10.00/��Q� CJ a: ,-02 ICENSED CONTRACTORS DECLARATIONPAID ¢ u u I hereby affirm that.l,am licensed under provisions of Chapter 9 ISSUANCE DATE v, ¢ i ° '^ (commencing with Section 7000) of Division 3 of the Business and 18L- E PLG. MECH. Professions Code, and my license is in full force and effect. Z o o L El License Class Lic. Number ❑ ° Zrn - ° H w Date Contractor ' ¢ w OWNER -BUILDER DECLARATION • Y ""4'fd'�S1}MATION PERMIT x ° a 3 . 1 hereby affirm that 1 am exem t'(rom the Contractor's License MISC,- -, REFER TO ORD p u N Fa o ¢ VALUATION $/FT. Law for the following reason. (Sec. 703 1.5, Business and Professions PERMIT ISSUANCE 6.00 w i i Code: Any city or county which requires permit to construct, alter, /0/000 ¢ ¢ Q o ° - in ,demolish, or repair any structure, prior to its issuance, also ELEC. CONTR. LIC. NO. ELEC. Lu a ¢ requires the applicant for such permit to file a signed statement that - TOTAL PERMIT TO X m y he is licensed pursuant to the provisions of the Contractor's License Law 9 7000) 3 F Z > (Chapter (commencing with Section o(Division o(the a Business and Professions Code) or that he is exempt therefrom and QTY. PLUMBING PERMIT FEE ¢ o the basis for the alleged exemption. Any violation o(Section 7031.5 STORIES' TYPE CONSTR. d 3 s' by any applicant for a permit subjecithe applicant toacivil penalty ALTER -DRAIN & VENT -WATER (EA.) 4.00 of not more than five hundred dollars (5500).): O I, as owner of the property, or my employees with wages as BACK FLOW PROTECT. DEVICE 2.00 OCC. GROUP RES. UNITS. their sole compensation, will do the work, and the structure is not - intended or offered for sale (Sec. 7044. Business and Professions DRAINS -FLOOR, ROOF, AREA,COND. 4.00 Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work FIXTURES - PER TRAP 4.00 SO. FT. FLOOR AREA TOTAL ACREAGE himself or through his own employees, provided that such improve- ments are not intended or offered for sale. If, however; the building GAS- EA. SYSTEM - 1 INC.4 OUTLETS 4.00 or improvement is sold within one year of completion, the owner- GAS - EA. SYSTEM -OVER 4 IEA) 100 BUILDING USE builder will have the.burden of proving that he did not build or im- . . RES IND CON PB Other prove for purpose of sale.). INDUSTRIAL WASTE INTER. 20.00 O 1, as owner of the property, am exclusively contracting with ❑ ❑ ❑ ❑ ❑ licensed contractors to construct the project (Sec. 7044, Business LAWN SPRINKLERS- 1 INC 5 V.B. 5.00 ASSESSORS PARCEL No. . .and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who LAWN SPRINKLERS - OVER -5 (EA.) 1.00 contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law. SEWER -SANITARY -STORM EA.200ft/8.00 TRACT NO. PARCEL NO. ❑ I am exempt Linder Sec. .'B:&P.C. for this WATER HEATER W/VENT 4.00 eason Dat Owner WATER SYSTEM 4.00 ACC. DATE ACC. FILE NO. �DICL WORKE�CO�P�INSA'TION ,LT10WATER TREATING EQUIP. 4.00 1 hereby affirm that I have a cerli(icate.o(consent to self -insure. or a certificate of Workers' Compensation Insurance, or a certified ZONING ENG. SITE NO. copy thereo((Sec.380.0,.Lab:C.). Policy No. Company O O Certified Copy is hereby furnished. FIRE SPRINK ENERGY T-24 Z Z. O O Certified copy is filed with the city inspection division. ' MISC. - REFER TO ORD. Applicant � �� v � N❑ Y ❑ N❑ ~ N ''' � PERMIT ISSUANCE 6.00 FLOOD ZONE A.L.U.C. CERTIFICATE OF EXEMPTION FROM WORKERS W C- ° PLG. COMPENSATION INSURANCE PLG. CONTR. LIC. No. Y ❑ N ❑ v [:] N ❑ TOTAL :D Z (This section need not be completed i( the permitis for one U O hundred dollars (S 100) or less.) I certify that in the performance of the work for which this per- CITY. MECHANICAL PERMIT FEE FEE SUMMARY LL H mit is issued, I shall not employ any person in any manner so as to O w become subject to the Workers' Compensation Laws,o(California. p Date Applicant BUILDING o u CL ALTER OR ADD TO MECH. 4.00 NOTICE TO APPLICANT: if, after making this Certificate of Ex- } rn PLAN CHECK Z emption, you should become subject to the Workers' Compensation APPLIANCE 4.00 provisions of the Labor Code, you must forthwith comply with FEE V such provisions or this permit shall be deemed revoked. AIR HANDLING UNIT (TO 10=C.F.M.) 3.00 SEISMIC FEE Q CONSTRUCTION LENDING AGENCY AIR HANDLING UNIT(OVEH10=1C.F,M.) 5.00 I hereby affirm that there is a construction lending agency for EXHAUST HOOD (WITH DUCT) 2.00 the performance of the work for which this permit is'issued (Sec. MICROFILM. 3097,Civ.CJ. HEATING UNIT (TO 100,000 B.T.Uj, 4.00 ELECTRIC - Lender's Name Lender's Address HEATING UNIT (OVER 100,000,B.T.U.)7.50 I certify that I have read this application and stale that the above VENTILATION FAN (SINGLE) 3.00 -- information is correct. I agree to comply with all city and county PLUMBING ordinances and state laws relating to building construction, and. BOILER - COMP (3H.P,Or100,000B.T.U.) 4.00 MECHANICAL hereby authorize representatives of this city to enter upon the above-mentioned properly for inspection purposes. BOILER -COMP (Over 100,000 BTU) SEE FEE SCH. (We) agree to save, indemnify and .keep harmless the. City of MISC. - REFER TO ORD. and expenses which PERMIT ISSUANCE 3.00 Cupertino a ainst liabilities, judgmeVCito CONST. TAX any ac ue inst saicons e uence f.the gran in f rill . MECH. CONT: LIC. NO. MECH. 2 TOTAL TOTAL op SignatureofApplican[Contractor ate' OFFICE COPY i u J� APPLICANT TO FILL IN INFORMATION WITHIN RED LINES - USE BALL_ POINT PEN ONLY BU NG PROJECT IDENTIFICATION APPLICATION & PERMIT BUILDING — ELECTRICAL— PLUMBING — MECHANICAL PERMIT NUMBER 3 8 7 0 I -DING OGRESS Af ,V (4, • w OWNER'S -- Z- . 'Y Q �—e ,At rPHONE -� QTY. ELECTRIC PERMIT FEE PLAN CHECK VALIDATION - r• " DATE OF APPLICATION c NTRACTO s NAME Nd{'i�_ Lt C.n,��'Z� OUTLETS - SWITCHES - RECEP 5.00/1:00 LIGHTING FIXTURES 5.00/1.00 CONTRACTOR'S - ADDRESS e nm4 ra b � U I PHONE M APPLIANCES -RESIDENTIAL 4,00 PANELS 5.00 ARCHITECT - OR ENGINEER LIC: No. SIGNS 6.00 PLAN CHECK FEE P.C. NO. SIGNS TRANS. 3.00 ADDRESS ENG. SPECIAL CIRCUIT 5.00 PERMIT VALIDATION EMP. METER OR POLE INS. 15.00 I ZIP / APPLICANTS ADDRESS - '' MOTORS SEE 'FEE SCH- SERVICE CHANGE 10.00 y LICENSED CONTRACTORS DECLARATION hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Cod an license is in full rc�n* c License Class Lic. Numbe ISSUANCE DATE BLDG. ELECT. PLG. E ate on[racto i BUILDING PERMIT INFORMATION a ¢ Z OWR-BU R DE13CLARATIOQ � I hereby affirm that I am exempt from the Contractor's License Law for the following reason. (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file:a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that'he isexempt-therefrom and MISC. — REFER TO`ORD VALUATION .$/FT., PERMIT ISSUANCE 6.00 ELEC. CONTR. LIC. NO. ELEC. TOTAL PERMIT TO + QTY. PLUMBING PERMIT FEE STORIES TYPE CONSTR. the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant toacivil penalty of not more than five hundred dollars (5500).): ALTER -DRAIN &VENT -WATER (EA.) 4.00 ❑ I, as owner of the property, or my employees -with wages as their sole compensation, will do the work, and the structure is not BACK FLOW PROTECT. DEVICE 2.00 OCC. GROUP RES. UNITS DRAINS -FLOOR, ROOF, AREA,COND. 4.00 intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improve- ments are not intended or offered for sale. If, however, the building FIXTURES - PER TRAP 4.00 SD. FT. FLOOR AREA TOTAL ACREAGE GAS - EA. SYSTEM - 1 INC.4 OUTLETS 4,00 or improvement is sold within one year of completion, the owner- builder will have the burden of proving that he did not,build or iln- prove for purpose ofsale.). ❑ 1, as owner of the property, am exclusively contracting with GAS EA. SYSTEM -OVER 4 (EA.) 1.00 BUILDING USE ' S IND CON PB Other ❑ ❑ ❑ ❑ INDUSTRIAL WASTE INTER. 20.00 LAWN SPRINKLERS- 1 INC 5 V.B. 5.00 licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds --or improves thereon, and, who ASSESSORS PARCEL NO. LAWN SPRINKLERS - OVER 5 (EA.) 1.00 contracts for such projects with a contr5ctor(s) licensed pursuant to the Contractor's License Law. SEWER -SANITARY -STORM EA. 200ft/8.00 TRACT NO. PARCEL NO. ❑ 1 am exempt under Sec. B.&P.C. for this reason WATER HEATER W/V ENT 4.00" Date Owner WATER SYSTEM 4,00 ACC. DATE ACC. FILE NO. WATER TREATING EQUIP. 4.00 WORKERS'COMPENSATION DECLARATION I hereby affirm that I have'a certificate of consent *to self -insure. or a certificate of Workers' Compensation Insurance, or a certified _ ZONING ENG. SITE NO. copy thereof (Sec. 3800, Lab.C.). y No.CompanyCertified - FIRE SPRINK- Y ❑ N ❑ ENERGY T-24 Y ❑ N❑ copy Is hereby furnished. - Cer' ed copy filed tl the city licant inspection divi on. \Apo MISC. - REFER TO OR,D. CERTIFICATE OF EXEMPTION FROM WORKERS' PERMIT ISSUANCE S. tOO FLOOD ZONE A.L. U.C. COMPENSATION INSURANCE (This section need not be completed if the'permit is for one PLG. CONTR. LIC. NO. PLG. TOTAL Y ❑ N ❑ Y E]N ❑ hundred dollars (S 100) or less.) I certify that in the performance of the work for which this per- mit is issued, I shall not employ any person in any manner so as to OTY. MECHANICAL PERMIT FEE FEE SUMMARY BUILDING become subject,to the Workers' Compensation Laws of California. Date --Applicant NOTICE TO APPLICANT: If, after making this'Certificate of Ex- ALTER OR ADD TO MECH. 4.00 APPLIANCE PAILJ 4.00 PLAN CHECK FEE emption, you should become subject to the. -Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. AIR HANDLING UNIT (TO 10,000C.F.M.) 3.00 AIR HANDLING UNIT (–MIgOV@ SEISMIC FEE CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for .. EXHAUST HOOD (WITH DUCT) 2.00 the performance of the work for which this permit 'is issued (Sec. 3097, Civ,.C.). MICROFILM Ef�I0 Lender's Name Lender's Address HEATING UNIT (OVER 100,000 B.T.U.) cS� � ELECTRIC - certify that I have read this application and state.that the above .00 information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and PLUMBING BOILER -COMP(3 H.P. Or 100,000 B.T.U.) 4.00 BOILER -COMP (Over 100,. 000 BTU) SEE FEE SCH MECHANICAL /0 hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. (We) agree to save, indemnify and keep harmless the City of Cupertino against. liabilities, judgments, costs and expenses which ma in an way accrue against said Cit Y Y Y g yin consequence of the MISC. - REFER TO ORD. - CONST, TAX � PERMIT ISSUANCE 3.00 granting of this permit. MECH. CONT. LIC. NO. MECH " L 0 TOTAL - Signature of Applicant/Contractor Date OFFICE copy x x x O z z O CC W _ CL 0 ::) z UO LL O w' >- a [n A X� APPLICANT TO, FILL IN INFORMATION WITHIN RED LINES - USE BALL POINT PEN ONLY BUI LDI NG PROJECT I DENTFFICATII APPLICATION & PERS4 BUILDING - ELECTRICAL- PLUMBING - MECHANICA PERMIT NUMBER �+ o .195 BUILDING ADDRES O OWNER'S NAME ,0 I L PHONE QTY. ELECTRIC PERMIT FEE PLAN CHECK VALIDATION " DATE OF APPLICATION CONTRACTOR'S NAME 1! �.r� Xv/h �jE , Lder7i6[I/ie`No�� OUTLETS -SWITCHES - RECEP 5.00/1.00 LIGHTING FIXTURES 5.00/1.00 CONTRACTOR'S ADDRESS 47 ,�� drPHONEJJJ-Z,;?3 PPLIANCES- RESIDENTIAL 4.00 PANELS 5.00 ARCHITECT OR* - •+ ENGINEER LIC. NO.' SIGNS 6.00 PLAN CHECK FEE - P.C. NO. , SIGNS TRANS. 3.00 ARCH. OR ENG.- ADDRESS SPECIAL CIRCUIT 5.00 PERMIT VALIDATION TEMP. METER OR POLE INS. 15.00 ZIP p�D' AAoDRESsTS MOTORS Z 2/ SEE FEE SCH. SERVICE CHANGE 10.00 AIlJ Irl7 - p 1983 LICENSED CONTRACTORS DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Cod , and my li e- a is in full force and' ff cy License C ; ` ' L Lic: Number Date Contractor +L4MX IS C TE_.. BLDG. ❑ E APM, H. ❑ BtPLDtNG PERMIT NFORMATION OWNER -BUILDER DECLARATION hereby affirm that.1 am exempt from the Contractor's License Law for the following reason. (Sec. 7031.5, Business and Professions Code: Any city or county which requires permit to construct, alter, MISC. = REFER TO ORD VALUATION , $/FT. PERMIT ISSUANCE 6.00 ELEC. CONTR: LIC. NO. ELEC.' TOTAL 3< - improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that Ite is'exempt therefrom and EBMI7 TO QTY. PLUMBING PERMIT FEE STORIES TYPE CONSTR. the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars'($500).): ALTER -DRAIN &VENT -WATER (EA.) 4.00 ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not BACK FLOW PROTECT. DEVICE 2.00 OCC. GROUP RES. UNITS - . DRAINS -FLOOR, ROOF, AREA,COND. 4.00 -intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improve- ments are not intended or offered for sale. If, however, the building FIXTURES.- PER TRAP -4.00 SO. FT. FLOOR AREA TOTAL ACREAGE GAS -EA. SYSTEM - 1 INC.4 OUTLETS 4.00 or improvement is sold within one year of completion, the owner- builder will have the burden of proving that he did not build or im- prove for purpose of sale.). O I, as owner of the property, am exclusively contracting with GAS - EA. SYSTEM -OVER 4 (EA.) 1.00 BUILDING USE RES IND CON PB Other ❑ ❑ ❑ ❑ ❑ INDUSTRIAL WASTE INTER. 20.00 licensed contractors to construct- the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon. and who LAWN SPRINKLERS - 1 INC 5 V. B. 5.00 ASSESSORS PARCEL NO. LAWN SPRINKLERS - OVER 5 (EA.) 1.00 contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law:. SEWER -SANITARY -STORM EA. 200ft/8.00 TRACT NO. PARCEL NO. O I am exempt under Sec. B.&P.C. for this reason WATER HEATER W/VENT 4.00 Date Owner WATER SYSTEM 4.00 ACC. DATE ACC. FILE NO. WORKERS'COMPENSATION DECLARATION WATER TREATING EQUIP. 4.00 I hereby affirm that I have a -certificate of consenl_lo self -insure. or a certificate of Workers' Compensation Insurance, or a ce tlfied - ZONING ENG. SITE NO. copy thereof (Sec. 3800, Lab.C.). Policy No. Company ��( �✓ K FIRE $PRINK ❑ WE],' ENERGY T-24 Y ❑ N❑ ❑ rtified co y Is hereby fu shed. ertifi c py is Filed wi t th ci ecn n - Ision. Applicango,'1 MISC. - REFER TO ORD.Y CERTIFICATE OF EXEMPTION FROM WORKERS' PERMIT ISSUANCE 6.00 FLOOD ZONE A.L.U.C. COMPENSATION INSURANCE (This section need not be'completed if the permit is for one Y ❑ N❑ Y ❑ N❑ PLG. CONTR. LICnNO_ PLG. TOTAL hundred dollars ($100) or less.) - I certify that in the performance of the work for which this per mit is issued, I shall not employ any person in any manner so as to QTY. MECHANICAL PERMIT FEE FEE SUMMARY BUILDING become subject to the Workers' Compensation Laws of California. Date Applicant ALTER OR ADD TO MECH. 4.00 NOTICE TO APPLICANT: If, after making this-Certificatc of Ex- - APPLIANCE 4.00 .'PLAN CHECK FEE emption, you should become subject to the Workers' Compensation provisions,of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. AIR HANDLING UNIT (TO 10=OC.F.M.) 3.00 AIR HANDLING UNIT(OVER10=C.F.M,)5.00 SEISMIC FEE CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction -lending agency for the performance of the.work for which this permiljs issued (Sec. 3097,Civ.C.). EXHAUST HOOD (WITH DUCT) - 2.00 MICROFILM HEATING UNIT (TO 100,000 B.T.U.) 4.00 Lender's Name Lender's Address - HEATING UNIT (OVER 100,000 B.T.U.)7.50 ELECTRIC I certify that I have'read this application and state that the above VENTILATION FAN_ (SINGLE) 3.00 information is correct. I agree to comply with all city and county ordinances and stale, laws relating. to building construction, and PLUMBING BOILER-COMP(3 H.P. or 100,000B.T.U.) 4.00 hereby authorize representatives of this city to. enter upon [lie- above-mentioned property for inspection purposes. BOILER -COMP (Over 700,000 BTU) SEE FEE SCH. _ MECHANICAL (We) agree to save, indemnify and keep, harmless the City of MISC. - REFER TO ORD. Cupertino against liabilities, judgments, costs and expenses which may in y way accrue against'said City in consequence of the CONST. TAX PERMIT ISSUANCE 3.00 granti f [his permit - �d MECH. CONT. LIC. NO. - MECH. TOTAL TOTAL Signature of Applicant/Contractor Date _ OFFICE COPY O Z z O N LU > CL 0 :D z U..O LL U OW } a rn I— ? AE 0 APPLICANT TO FILL IN INFORMATION WITHIN RED LINES- USE BALL_ POINT PEN ONLY - - BU LDI NG PROJECT IDENTI FICATIO EU APPLICATION &PERM ELECTRICAL- PLUMBING -MECHANIC PEaMIr,NUMBER jjo7QADDR `tQ1 "Bu WING t�Sa`�� lJ�� OWNER'S N ME a � a PHONE 3 V TY. ELECTRIC PERMIT FEE PLAN CHECK VALIDATION ' CONTRACTOR'S t NAME OUTLETS •.SWITCHES - RECEP 5.00/1.00 LIGHTING FIXTURES 5.00/1.00 LIC. NO. CONTRACTOR'S AODRESS - APPLIANCES' RESIDENTIAL 4.00 PANELS 5.00 PHONE DATE OF APPLICATION ARCHITECT OR ENGINEER LIC. NO. SIGNS - 6.00 PLAN CHECK FEE - P.C. NO. SIGNS TRANS. 3.00 ARCH. OR ENG.SPECIAL ADDRESS - CIRCUIT �j,QQ PERMIT VALIDATION :e EMP. METER OR POLE INS. 15.00 ZIP c nISSUANC APPLICANT'S ADDRESS MOTORS' SEE FEE SCH. SERVICECHANGE 10.00LICENSED CONTRACTORS DECLARATION I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. Number - _ DATE BLDG. ❑ I ELECT.1 ❑ PLG. I MECH. ❑ Date Contractor I BUILDING PERMIT _ OWNER -BUILDER DECLARATION hereby affirm that I am exempt from the Contractor's License Law for the following reason. (Sec. 703 1.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to, file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 MISC. — REFER TO ORD PERMIT ISSUANCE 6.00 ELEC. CONTR. LIC. NO. ELEC. TOTAL OTY. PLUMBING PERMIT 1 FEE I INFORMATION VALUATION -7 $/FT. PERMIT TO STORIES TYPE CONSTR. by any applicant for apermit subjects the applicant"toacivil penalty of not more than five hundred dollars (S500).): ALTER -DRAIN & VENT -WATER (EA.) 4.00 ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not BACK FLOW PROTECT. DEVICE 2.00 OCC. GROUP RES. UNITS intended or offered. for sale (Sec. 7044, Business and Professions Code: The Contractor's License'Law does not apply to an owner of.. property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improve- ments are not intended or offered for sale. If, however, the building DRAINS -FLOOR, ROOF, AREA,COND. 4.00 F IXTUR ES - PER TRAP 4.00 GAS - EA. SYSTEM - 1 INC.4 OUTLETS 4.00 SO. FT. FLOOR AREA TOTAL ACREAGE or improvement is sold within one year of completion, the owner - builder will have the burden of proving that he did not build or im- prove for purpose of sale.).RES ❑ I, as owner of the property, am exclusively contracting with GAS - EA. SYSTEM - OVER 4 (EA.) 1.00 INDUSTRIAL WASTE INTER. 20.00 BUILDING USE IND CON- PB Other licensed contractors to construct the project (Sec. 7044.; Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who LAWN SPRINKLERS -, 1 INC 5 V.B. 5.00 LAWN SPRINKLERS - OVER 5 ( ImIlsoo ,. ASSESSORS PARCEL NO. contracts for such projects with a contractor(s) licensed pars t to the Contractor's License Law. SEWER -SANITARY -STORM EA.200ft/8.00 TRACT NO. PARCEL NO. ❑ 1 am exempt under Sec. ,B eP or s reason WATER HEATER W/VENT'S 4 Date WATER SYSTEM 4, ACC. DATE ACC. FILE NO. ATION DE .L RATION WOR ERS'COMVea5certificate WATER TREATING EQUIP CUOdM hereby affirm that 1 h of onsent to self -insure. or a certificate of Workers' Compensation Insurance, or a certified copy lhereof.(Sec. 3800, Lab.C.). Policy No. Company 'it, pf 10 _ ZONING ENG. SITE NO. ❑ Certified copy is hereby furnished. ❑ Certified copy is filed with. the city inspection division. Applicant MISC. - REFER TO ORD. FIRE SPRINK Y ❑' N❑ ENERGY T-24 Y ❑ • NO ... CERTIFICATE OF EXEMPTION FROM` WORKERS' PERMIT ISSUANCE 6.00 FLOOD ZONE A.L.U.C. COMPENSATION INSURANCE (This section need not be completed if the permit is for one PLG. CONTR. LIC. NO. PLG. TOTAL 1 Y ❑ NE]Y ❑ N❑ hundred dollars (S 100) or less.) I certify that in: the performance of the work for which this per- mit is issued, I shall not employ any person in any manner so as to OTY. MECHANICAL PERMIT FEE FEE SUMMARY BUILDING' ' become subject to the Workers' Compensation Laws of California. Date Applicant NOTICE TO APPLICANT: If, after making this Certificate of Ex- ALTER OR ADD TO MECH. 4.00 PLAN CHECK FEE emption, you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. APPLIANCE 4.00 AIR HANDLING UNIT (TO 10=C.F.M.) 3.00 SEISMIC FEE, CONSTRUCTION LENDING AGENCY AIR HANDLING UNIT (OVER 10)=C.F.M.)-5.00 I hereby affirm that there isra construction lending agency for EXHAUST HOOD (WITH DUCT) '2.00 the performance of the work for which this permit is.issued (Sec.' 3097, Civ.C.). HEATING UNIT (TO 100,000 B.T.U.) 4.00 MICROFILM ELECTRIC i Lender's Name Lender's Address H EATING UNIT (OV ER 100,000 B.T.U.)1.50 I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and VENTILATION' FAN (SINGLE) 3:00 BOILER - COMP (3 H.P. or 100,000 B.T.U.) 4,00 PLUMBING 0� •— MECHANICAL hereby authorize representatives of this city to enter upon the BOILER -COMP (Over 100,000 BTU) SEE FEE SCH. above-mentioned property for inspection purposes. (We) agree to save, indemni nd keep harmless the City of MISC. = REFER TO ORD. Cupertino against liabilities, j g It S, costs and expenses which may w accrue g ' said City in co se u of the gra Oft " rmlt. PERMIT ISSUANCE 3.00 CH. CONT. LIC. NO, MECH.A 1 CONST. TAX ✓ AL �S[Aatur_ „' TOTAL. TOTAL e of p a Contractor ate 11. V — V . 1 A4 OFFICE COPY o ¢ z X00 w ¢ U V F'z w y Q wz N z Z 0.- 0z-0 y � w 4 Y E J ¢ ¢ Cc w U a O a " 3 LL LL O ¢ � y J i w E w ¢ 0 O a a ¢ x O LL W m N �z>- a i=o ¢I -o r O Z Z, y W � d;� D �z 80 LL Ow a to ~ Z U a APPLICANT TO.FILL"IN INFORMATION WITHIN RED LINES - USE BALL POINT PEN ONLY BUILDING PROJECT I DENTI FICATI APPLICATION & PERP BUILDING - ELECTRICAL- PLUMBING - MECHANICAL �-_ PERMIT NUMBER _ 4054 - ' aUILDING ADDREss OWNER'S NAME �/S QTY. ELECTRIC PERMIT FEE PLAN CHECK VALIDATION - 6 PHONE,3-1 - - CONTRACTORS' NAM .L OUTLETS- SWITCHES -RECEP 5.00/1.00 LIGHTING FIXTURES - 5.00/1.00 /L)_r1 OGAel VeZIg. LIC.NO. s 60 - _ DATE OF APPLICATION CONTRACTOR'S - ADDRESS �',.{ �E.D«%ooD C¢/S if 7/ li-. e1% ONE',3 b APPLIANCES• -RESIDENTIAL 4.00 PANELS 5.00 ARCHITECT OR ENGINEER LIC. NO. SIGNS 6.00 PLAN CHECK FEE P.C. NO. - SIGNS TRANS. 3.00 AARCH DRESS ENG. SPECIAL CIRCUIT 5.00 PERMIT VALIDATION TEMP. M.ETER,OR POLE INS.. 15.00 Z,P;<, w X9,1 / APPLICANT'SMOTORS. ADDREDDRESSSSERVICE SEE FEE SCH. CHANGE 10.00Au 'LICENSED.CONTRACTORSDECLARATION hereby affirm that 1 am licensed under provisions of Chapter 9- (commencing with Section 7000) of Division 3 of the Business and Professions Co�ysand�• y licensees in full (organ License Class `--✓Lic. Number6 Date :±c/Ca E= Contractor ISSUANCE DATE - -BLDG. ❑ ELECT. PLG. MECH. . : ❑ BUILDING PERMIT INFORMATION OWNER -BUILDER DECLARATION I hereby affirm that I amexempt from the Contractor's License' Law for the following reason. (Sec. 7031.5, Business and Professions' Code: Any city or county which requires a permit to construct, altar, improve, demolish, or repair any structure, prior to its issuance, also requires the 'applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law,(Chapter 9 (commencing with Section 7000) of Division 3 of.the Business and Professions Code) or tHat he is exempt therefrom and MISC. - REFER TO ORD ' VALUATION , $/FT. -PERMIT ISSUANCE 600 6.00 ELEC. CONTR. _ LIC. NO. ELEC. TOTAL ' PERMIT TO QTY. PLUMBING PERMIT FEE STORIES TYPE CONSTR. the basis for the alleged exemption. Any violation,of Section 7031.5 "' by any applicant for a permit subjects the applicant to civil penalty' of not more than five hundred dollars (S500).):. ALTER -DRAIN &VENT -WATER (EA.) 4.00 ❑ I, as owner of the property, or my employees with wages as. their sole c'ompensaiion, will do the work, and the structure is not ' BACK FLOW PROTECT. DEVICE 2.00 OCC. GROUP RES. UNITS DRAINS -FLOOR, ROOF, AREA,COND. 4.00 intended or offered for sale (Sec.. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds Or improves thereon, and who does such work himself or through, his own employees, provided that such improve- ments are not intended or offered for sale. If, however, the building 2 FIXTURES - PER TRAP 4.00 . 00 SO. FT. FLOOR AREA TOTAL ACREAGE GAS -.EA. SYSTEM- 1 INC.4 OUTLETS 4.00 4 • DO or improvement is sold within one year of completion, the owner builder will have: the burden of proving that he did not build or im- prove for purpose of sale.)' ❑ 1, as owner of the property, am exclusively contracting with GAS - EA. SYSTEM - OVER 4 (EA.) 1.00 BUILDING USE RES IND CON PB Other . ❑ _❑ ❑ ❑ ❑ INDUSTRIAL WASTE INTER. 20.00 licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who LAWN SPRINKLERS -.1 INC 5 V.B. 5.00 ASSESSORS PARCEL NO. - LAWN SPRINKLERS - OVER 5 (EA.) 1.00 contracts for such projects with a.conlraclor(s) licensed pursuant to the Contractor's License Law. SEWER -SANITARY -STORM EA, 200ft/8.00 TRACT NO. PARCEL NO. Cl I am exempt under Sec. BAP.C. for. this WATER HEATER W/VENT 4.00 reason Date Owner WATER SYSTEM 4,00 PAID ACC: DATE ACC. FILE NO. WATER TREATING EQUIP, 4.00 WORKERS',COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate$ of Workers' Compensation Insurance, or a certified ZONING ENG. SITE NO. cop PolcyNdcEd.JTe�.Q/SCS• AUG MISC. - REFER TO ORD. FIRE SPRINK - Y ❑ N ❑ ENERGY -T-24 Y ❑ N❑ ❑ Certified copy Is hereby furnished. 0 Certif copy is filed =Lit city inspection division. Applicant�- - l��-o-�nr CERTIFICATE OF EXEMPTION FROM.WORKERS PERMIT ISSUANCE 6.00 FLOOD ZONE A.L. U.C. P{1 T�GD�C/`'O�NTR. uC PLG.' /' w� /"EiC. C TOTAL O a /rl6. S COMPENSATION INSURANCE (This section need not be completed• if the permit is for one Y❑ N❑ Y❑ N❑ QTY. MECHANICAL PERMIT . FEE - FEE SUMMARY hundred dollars (S 100) Or less.) I certify that in the performance of the work for which this per- mit is issued; I shall not employ any person in any manner so as to BUILDING become subject- to the Workers' Compensation Laws of.California. Date Applicant ALTER OR ADD TO MECH. 4.00 NOTICE TO APPLICANT: If, after making this Certificate of Ex- APPLIANCE- 4.00 PLAN CHECK emption, you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith,comply with such provisions or this permit shall be deemed revoked. FEE AIR HANDLING UNIT (TO 10=C.F.M.) 3.00 AIR HANDLING UNIT(OVER10MOC.F,M.) 5.00 SEISMIC FEE CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for EXHAUST HOOD (WITH DUCT) 2,00 the performance of the work for which this permit is issued (Sec. 3097,Civ.C.). MICROFILM HEATING UNIT (TO 100,000 B.T,U.) 4.00 Lender's Name Lender's Address HEATING UNIT (OVER 100,000 B.T.U.)7.50 ELECTRIC I certify- that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and VENTILATION FAN (SINGLE) 3.00 PLUMBING - BOILER - COMP (3 H.P. or 100,000 B.T,U.) 4.00 BOI LER-COMP (Over 100,000 BTU) SEE FEE SCH. MECHANICAL hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. (We) agree to save, indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs and expenses which may in any way accrue against said City in consequence of the - MISC.: REFER TO ORD. CONST. TAX ' " PERMIT ISSUANCE 3.00 ranting Of this permit.- - '• MECH: CONT. LIC. NO. MECH. TOTAL TOTAL Signature of Applicant/ ntractor Date OFFICE COPA _ C I T Y O F C U P E R T I N 0 4 Building Division PROJECT CONTROL # o! ADDRESS /'D S' L,q vGl PER=, OWNER PHONE A.P.N. # ADDRESS SAN. # REP. �oy�gtg GSSac PRONE 3S BLDG. TYPE ARCHITECT PHONE OCC. GROUP ADDRESS REP. PHONE CONTRACTOR PHONE VAL. $ /O oc)o ADDRESS STRUCT.PLAN CK REP. PHONE BG'.PLAN.CK S� 3 LD PLAN CHECK HOURS 4-0 PER]AIT FEE CAP FEEd CONST. TAX ENERGY FEE PUBLIC tUORKS MICRO FILM FEE TOTAL FEES 1st. Submittal 2nd. Submittal 3rd. Submittal DATE REC. DATE REC. * ,DATE REC. DATE REC. * DATE REC. DATE REC. BLDG. DEPT. EINr,. DEPT. PLAN. DEPT. STRUCT. ENG. - ENERGY n HEALTH DEPT. — SAN. DIST. CENTRAL FIRE DIST. HANDICAPPED A. - APPROVED * N.A. - NOT APPROVED CUPERTINO INSPI.,CTIO1' RECORD (Office Copy) r, 3600 10839 S. Blaney Avenue PI,PJIIT NO. SANITARY DIST. 170. LOT 1.10. ADDRESS Interior Remodel JA 11oreing PROJECT OWNER JOB SITE PHONE NO. PERMIT ISSUED Date ELECTRICAL Ru.iIdin p, Date Insp. Electrical Power Pole Plumbing; Under ,round ilcchanical Rou'h Wirin Temp. (;zs/Elect. Solar Fire Sprinkler Sign Hisc. s _jV Electric $- 101 V +Plumbin , &- ,& Mechanical Solar Pool Gradin l In nin inrP De t. Ilealth Dept. Building o K? - Other 9 4 IV 3 BUILDING Date ' Insp. Foundation Pre-Gunite Slab -Membrane Bond Ream Underf.lnor Girders Floor Steel Tiedowns niaphrams Seismic Bracing halls-Pancls Frame Lnth Wallboards n /Ext. Firewalls Other Not Apnroved [falls Ceiling Fixtures Int/Ext Notors Grounding Temp. Power Other _ Not Annroved PLUMBING Date Backflow Insp. Underground Underfloor Fire Dampers Par -tial Rough Fireplace Rough Complete Grease Duct & ]food Solar Rough One }lour Shaft Water & Insulation Condensate Drain Main Drain Equipment Anchorage R/of/S Drain Flues & Comb. Air Gas Other Other Not Approved Not Approved MECHANICAL Date Underfloor S.M. Insp. Ducts & Insulation Fire Dampers Fireplace Grease Duct & ]food _ One }lour Shaft Condensate Drain Equipment Anchorage Flues & Comb. Air Other Not Approved BUILDING ELECTRICAL PLUMBING ?frrTJ AM Tr AT MISCELLANEOUS c A� �a r • f 144, el ? '3 w d' G 6- Cr'sr / /er�'_/�.f�w"('! •"d!` ..1�,''G+r6il:� CLQ D Lag f— v sG4 ..91!Z1::,zhE } -444` r ,z5*kui �Mt rl y� k I Ni v, i � 4 J C t �C tf54�m tx t j.�'"rWH MX 3`w ��ys.�3. it,F r ` r t'fi!-r�u ya 9,83' y p_ ry . k y � �9,8 sJs r" r '=. S d `v RZO..t 'i J"pLR � A.�. i d � _R`i# i) ,�:' C,4 5 t ! ___kkk�iii Mry y I {x ,, „'a !re'y,rv�, i ' ,r" +`fit' r= i„ t { �. ��.'i- � n ^° Lx T BLbG (tf1N�S/PECXa('OtN `DpErPAR(j i.f�t�N6S:� ,PRIMiIN IUll NIX =''` '4+'ri� u i� a#a.=ryf_,�,+y } dial '+ fi3.?. t. a" !P �`a"`J, xt�.' _ x - x *r' l{. fir^- 'r• [ .t r''Y "'''c+ ,r • ,i as - _ w�E C 1 )G c`Sv `l� ft'r e' Rr cs3^ irs M. M. . ^� i 4 'N l, f fY34' r� 41 5h x1�' .v,.''i•nT�. "5 t'rrmy�sr��r�,` q"e rs �� fvp'"r'a7'�d{a7 .•� xy--x-4 4 gg.- C+�'�'lt+. . ''1 .��''��w,,y',�" rs•+c'&�t� ua - ���Y�' k,T~t'�" w rty�r%'� 1 3 �. MW- 'Y"t } 890 SARATOGA AVENUE LISi0N & ASSOC IAiQS MECHANICAL ENGINEERS Machinery for Baking Company 1485 Bayshore Boulevard San Francisco, California 94124 Attn: Gordon Wilkerson Pr ,!ft- : Jack & Jill Bakery ,,!ft -: Gas Oven (408) 246-6281 August 30, 1983 tW SAN JOSE, CALIFORNIA 95129 At your request I did this date inspect one natural gas oven and one natural gas donut fryer at the: Jack & Jill Bakery 10889 South Blaney Avenue Cupertino, California. The 150,000 Btu/hr input oven was put through its paces. All systems functioned well. No safety hazards in the unit itself were observed: The gas controls are a Honeywell Y86G electric ignitor, which is a proper selection for this natural draft oven. The 150,000 Btu/hr donut fryer was operated briefly. A full test could not be performed, as the fryer was empty. This unit has a standing pilot, manually lit. All burners lit properly when tested. The controls on the donut fryer are suitable for the application. The bakery's provisions for combustion air are not satisfactory, as they rely entirely upon the operation of a make-up air blower. The blower is not interlocked with gas controls. The gas -burning devices within the bakery are: Oven Donut fryer Pot burner Furnace Hot water htr TOTAL .... * = Estimated. 150,000 Btu/hr Natural draft 150,000 Btu/hr Hood -vented. 150,000 Btu/hr4 Hood -vented. 150,000 Btu/hr4 Natural draft. 60,000 Btu/hrr*- Natural draft. 660_,000 Btu/hr. Page 1 of 2 To consider this installation to be safe, I would recommend the following: 1. Interconnect gas to two hood -vented appliances with range exhaust fan. Reference: UFIIC'79, Sec.917(c), °Interlock Controls.* When the ventil- ating hood or exhaust system is equipped with power means of exhaust, the appliance control system shall be interlocked so as to permit appliance oper- ation only when the power means of exhaust is in operation.° Note that neither of the two hood -vented devices have automatic ignition. Thus, new interlocking automatic gas shut-off valves will have to be in main gas lines (but not pilot gas lines); or units will have'to be modified for automatic pilots. 2. Provide permanent combustion air openings to bakery (for those times when make-up air &/or exhaust fans are off, i.e. for those gas burning devices which are not hood -vented). Reference: UNC'79, Sec.608, "Properly designed permanent facilities to supply ample amounts of outside air to permit complete combustion of the fuel shall be provided. Where any portion of the combustion air is taken from the space in which the fuel-buring appliance is located, a permanent opening to the outside shall be provided having an area at least .5 square foot per 1,000,000 Btu/h input rated at the altitude of installation. Adequate ventilation of the boiler or furnace room shall be provided to pre- vent the development of an explosive atmosphere should leaks occur. The ventilation provided shall be so designed as to maintain atmospheric or pos- itive pressure at all times.° 3. The natural draft vented appliances should not be allowed to fire when the hood exhaust fan is on and the make-up air fan is off, as a strong negative condition was observed to exist (as might be expected) under this condition. Although the two fans are interlocked with a relay, it is none - the -less easy for the operators to turn off the make-up air fan (while the exhaust fan continues to run) using a circuit breaker. Indeed, the electri- cian demonstrated same. To accomplish this, it is recommended that both fans be put on a common circuit. Reference: UMC'79, Sec.2003(i), *Makeup Air. Each room provided with an exhaust system shall have air supplied to the room equal to the amount of air to be exhausted. Makeup diffusers shall be located to prevent a short-circuiting of air furnished to the exhaust system. Windows shall not be used for the purpose of provideing makeup air. The exhaust and makeup air system shall be connected by an electrical interlocking switch.' Very truly yours, Thomas L. Liston, P.E. Mechanical Engineer Copy to: City of Cupertino Building Inspection Department Attn: Mr. James West, Building Inspector -CM �t A10 , J � ' i _� { .Down DsGaf�9.gva orat�ve Coolers CITY N Nominal capacilies 300010 21000 cfm* Down dischargeevaporative coolers are specifically designed to•deliver maximum cooling efficiency in a rooftop installation. Down discharge units feature: • Four -point vibration isolation (blower bearings, riser, motor. and channel support) for quiet operation in Standard units. • Polybond electrostatically applied paint finish (appliance type) is resistant to scratches and corrosion, insuring a durable surface and long-lasting factory -fresh look. Scale washes off easily. . • Channelled blower support arms for greater rigidity and strength. • AII-welded steel cabinet construction for maximum strength, durability, and reliability; • Pad frames.of embossed,stee_I for added rigidity, quiet operation and attractive appearance. 0 Drawn steel water pan for leak -free operation (Series 330 through 830). • Key and keyway blower pulley/shaft to insure positive locking and service reliability. • Ali underwater riser joints are sealed, water -tight. • Polybond electrostatically applied paint finish (powder base) also covers all pad frame surfaces, louvers, pad retainers, and troughs for resistance to corrosion and scale. • All units are available with City of Los Angeles approved motors. • Dams in troughs simplify levelling and insure more even pad saturation. • Pump and float installed on Standard 9 Blower wheels are balanced for smooth ruricBrig„_.guiet'operation. • Pump, and float kits available.for Large • Cabinets of, hot -dipped galvanized coolers as accessories to provide steel are durable, heavy duty • Convenient junction box:(City of Los optimum installation flexibility. construction for long life; made to Angeles -approved) to facilitate easy' • Butyrate ` plastic water distributor withstand heat a ultraviolet ,-1 P are built to last.. and ult violet installation and.servicing, on.Standard .._,;__,,,, •; F'J units. tubes; -`for corrosion=free operation-' 'Industry standard rating • AMCA.Standard 210-74. performance • Debossed bottom pan (below pad test data on air delivery.(details inside), frame and. at blower mouth) for extra. for.accurate air balance and system strength and alignment. design. 1980. McGraw -Edison Company ZCN BB OFFERS ADORE FOR YOUR DOLLAR INVESTMENT r .+ A retail duty revolving oven with construction details and sturdiness surpassing com- petitive standards. Newest of our four (4) models of revolving ovens making over 90 standard sizes available in four (4) distinct price ranges—from the least expensive—to quality and value without comparison. Always• ahead in design—.now Middleby-Marshall offers larger sizes and many ad- vantages in a compact, oven for the "Limited Pocketbook." SIZES: From 8 bun pan to 35 bun pan capacity. Four - five - six and seven trays. Floor space from 5' 1" by 6' 10" to 9' 8" by 9' 1". Although this Model M -M Jr. will match and surpass all competitive ovens offered, It is not represented to equal the quality nor value of our Middleby-Marshali Model H C--or-i Heavy Duty, or the Model K Standard Duty, Revolving Tray Ovens. Only Chubbuck-Middleby-Marshall offer an oven for every circumstance. You just can't go wrong on a Middleby-Marsholl oven. It's just a question of letting our representatives help you select the model and size for your particular job. IMMEDIATE SHIPMENT (1-2 -*ohs on forte sizes) SPECIFICATIONS: CONSTRUCTION 6" fully insulated walls. Heavy reel and stabilizer spider. Structural steel framing and supports. Factory pre -wired. All interior bearings long -life graphite Convenient 42" hearth height. bronze and alloy. Steam dome construction inner roof. Drive chain outside of baking chamber. Easy lift door. Drive and burner access from front of Wall prefabricated full size for 'easiest installation. oven. Rounded corners — easy to clean—neat (Split -oil tobricotion available on slightly longer delivery of small charge). appearance. Full safety pilot and thermostatic control. Door opening 2" longer than oven troy— Heavy solid steel (expansion controlled) easy loading. or open mesh steel trays. FINISH While porcelain enamel front Istandard). Aluminum -pointed sides and back. (Chub - buck rust resistant aluminum painted surfaces furnish excellent base for those wishing to onif l e,00sed v:olls with n;, Or, white enamel). DIRECT GAS FIRED ELECTRICALLY HEATED 5 . ' „B 2 O I, i ' F — 12- _T 9 .. ,'GAS SUPPLY �I�"GAS INTAKE 3 PH SUPPLY 8- STACK 13'5'1, OUTLET ELECTRICAL 1 1 PH 115 V 60 CY 20 AMP I CONNECTIONS •g • Lj 2.8• (MOTOR 6 CONTROLS) � 1 PH „5 V 20 AMPS _% HP DRIVE MOTOR '/, HP DRIVE MOTOR B' DOOR 1 PH 115 V 60 HZ '33/• 6' DOOR w 1 PH 115 V 60 HZ Lj VENT yEM MACHINERY MACHINERY COMPARTMENT COMPARTMENT /COMBINED COMBUSTION d DOOR VENT BLOWER 6' DIA INLET 4'I,' x 7'I,' OUTLET 525 CFM AT/�' SPCOVER BOX FOR ELECTRIC HEATERS '/• HIP 1 PH 115V 60 CY AC MOTOR (OPTIONAL) {r . }. A f ?;;_ .: - • ;�i' •.�` -`nor, _ `,�.>[��,�.. , ACCESS DOOR 1 MOTOR SWITCH d ROD 4, 'fib FRONT. ELEVATION° t ACCESS DOOR MOTOR SWITCH 6 ROD _cf EVATION':. �y-MAX.: 3 PH. 208 V. :.3 PH. 2 OVEN'1? SIZE-••"• ..A•.':. KW�,'�.+:.,AMPS;'i;KW PR•15�` 9'3' 38 PR -20 11'3" •j ; 48 134 ' 44 PR -25 12'3' S7.8� , '': 160 81.7 , V:,y 3 H. 480 V MAXss MPS:. ','.KW :i,: �ANIF }].1, , _ 47.9 58 139 57.6, 70 STEAM REQUIREMENTS 1 12" X C" STANDARD DOOR OPENING NOTSHOWN 2 STACK OUTLET .02 TO .04 W.C. (OPTIONAL) 1'6" MIN. FROM NON -MACHINERY SIDE OF OVEN TO WALL. 2.078HP--8 PSI ' REAR & MACHINERY SIDE MAY GO AGAINST WALL. --�- -""--- 2.76 0HF'--8 PSI__ ALL SERVICE SUPPLY LINES TO BE PROVIDED BY OTHERS. s.4seHP-ePsl MAY BE FROM ABOVE OR BELOW. — --- - Middleby Marshall A STEWART Company Middleby Marshall Oven Co., Inc. • 8300 Austin Ave. • Morton Grove, III. 60053 • (312) 966.8300 • Telex 9101223.0211 n REVOLVING TRAY OVENS — IMc....... H & K ELECTRICALLY HEATED Control Box Control Circuit I I ' I 6e IPH. 120V. 60HZ. \ 2 C h Electrical Supply Fil from abe for Heaters 3PHov. 208V, 220V, 230V, 440V, 460V. or 480V. 60HZ. 4 Side Entry Sliding Doors O' I I i Non -Firing Side Control Circuit WH. 120V. 60HZ. Electrical Supply l4 from above for 5" f --- B B C 5` L—D0- 2OR E T H 24'� 46" L PEEL HTI r. Heaters 3PH. 208V, 220V, 23OV. 440V, 46OV, or 480V. 60HZ. Control Box at Rear 30"L x 24"W x 9"D for 30" Enclosure — 30"L x 20"W x 9"D for 24" Enclsoure. --F Steam Supply Open Drain (Optional if steam sprays inside oven required and ordered) Access D6or NOTE: If entry from side deduct 15" from 30" enclosure and 12" ❑ from 24" enclosure. i -..iY.,s.>. :. j -..,I t�2. •--•",1p�:.,,�, �.ZtC�vti».i,.-il.�., =•±.i-ri�..'r:. 750 4 20x56 8 8'-10" 5'-10" 6'-5 5.000 480 8'-10" 3'6" T-0" 5'-10" I� 12" 4'-9" 6' 5" 13" 751 4 20x80 12 10'-10" 5'-10" .6'-5" Heater Terminal Cover G ENGINEERING DATA Motor Switch & Rod SKETCH NOT TO SCALE (See Chart) rc„i.o•• Sim. ►,T�To !a.Yq.r+.'.cr3Y.za.9 ' ..Vis.Ya�,)' f :' Q wq a..A;.'•n!C,..ii'wWf�•t�. �tcn : �r}o^,',�}.7+m•; [:'..: ,r•. -r, }. M.lr.�.•,p =,?•i.-otbta. .rT.ti, 00% :.,�.�_..7�..,' .'F :e.`• �-'�.�+1.i .. r ! 1 -..iY.,s.>. :. j -..,I t�2. •--•",1p�:.,,�, �.ZtC�vti».i,.-il.�., =•±.i-ri�..'r:. 750 4 20x56 8 8'-10" 5'-10" 6'-5 5.000 480 8'-10" 3'6" T-0" 5'-10" 2'-3718" 12" 4'-9" 6' 5" 13" 751 4 20x80 12 10'-10" 5'-10" .6'-5" 6,000 455 10'-10" 4'-5" T-0" 5'•10" 2'•3718•' 12" 6'-9" 6'-5" 13" 752.6 1 6 20x56 12 8'-10" 6'-11' T-3- 6,000 460 8'-10" 3'-5" T-0" 6'-11" 2'-103!8" 12" 4'-9" T3" 13- 753 6 23x56 12 8'-10" 7'-9" 7'•9" 6,700 450 8'-10" 3'-5" 2'-0" 7'-9" 3'-3L8" 12" 4'-9" T-9" 13" 754.6 6 20>a30 18 10'-10" 6'-11" T-3" 7,000 425 10'-10" 4'6" 2'-0" 6'-11" 2'-10318" 12" 6'-9" 755-5 5 26>a30 20 10'-10" 7'-9" 7'-9" 8,000 410 10'-10" 4'-5" 2'-0" T-9" 3'-3718- 12" 6•-9" 7''9" 13" 780 5 2666 15 10'-0" 8'-5" 8'-0" 9.100 460 10'-0" 3'-9" 2'6" 8'-5" 3.4i/7" 15" 4'-7" 81-0" 15" 781 5 26x74 20 11'6" 8'6" 8'-0'" 10.400 435 11.6•• 4'6" 2'6'" 8'S" 3'4"x.. 15" 6'1" 6'-0" 15" 782 5 26x92 25 13'-0" 8'-5" W-011 11,800 420 13'-0" 5'-3" 2'6" 8'-5" 3'4'17" 15" 7'-7" 8'a" 15" 783 5 26x110 30 14.6•• 8'-5" W-0" 13.100 1455 14'-6" 6'-0" 2'-6" 8'6" 314'/2' 15" 9' 1" 8'-0" 15" 719 6 26x60 18 10'4" 9'4" 8'-11" 11,500 445 10'4" 3'-11" 2'6" 9'4" 3'-10" 15" 4'-11" 8'-1111 15" 723' 6 2608 24 11'-10" 9'4" 8'-11" 12,500 1490 11'.10" 4'-8" 2'-6" TA" 3'-10" 15" 6'-5" 8' 11" 15" 724 6 26x96 30 13'4" 9'4" 8'-11" 13,500 1475 13"4" 5'6" 2-6" 9'4" 3'•10" 15" 7'-11" 8'-11" 15" 725' 6 26x110 36 14'6" 9'4" 8'-11" 14,500 1.125 14'-6" 6'-0" 2'-6" 9'4" 3'-10" 15" 9'-1" 8'-1111 15" 726' 8 26x96 40 13'-4" 10'-5" 10'-0" 16,500 1430 13'4" 5'-5" 2'6" 10'6" 4'4'/." 15" 7'.11" 10'-0" 15" 727' 8 26010 48 14'6" 10'-5" 10'-0" 17,500 1370 14'.6" 6%0" 2'-6" 10'3" 4'-0117" 15" 9--1" t0'-0" 15" 728' 8 26x134 56 16'6" 10'-5" 10'-0" 18,500 1350 16'6" 7'-0" 2'-6" 10'-5" 4'41/7" 15" 11'•1" 10'-0" 15" 729'•' 10 26010 60 14'6•• 11'-9" 11'4" 20,500 1315 14'-6" 6'-0" 2'-6" 111'9•' T-002" 15" 9'-1" 11'1" 15" 730" 10 26x134 7016'6" 11'9" 11'1" 21,500 1285 16' 6" 7'-0" 2' G' 11'9" 5'-0117" 15" 11' 1" 11'4" 15" 731 •' 10 26x146 80 17'6" 11' 9 1 t'4" 22,500 1260 17'-G' 7'6" 2'-6" 11'A" 5'-0'17" 15" 12'-1" --- 11'4" 15" Sizes 752 and 754 available with 4 trays 26" wide or 7 trays 18" wide. (752-7 and 754-7 for baking only; insufficient clearance for roasting. Sines 723, 724, 725 available with 5 trays 30" wide or seven trays 23" wide. Sizes 726, 727, 728 available with 9 trays 23" wide, 7 trays 28"' wide, or 6 trays 30" wide. Shell dimensions not affected. Sizes 729, 730, 731 available with 11 trays 23" wide or 9 trays 28" wide. t Width measurements based on front entry. For side entry deduct 12" from 750 series, 15" from all others. AIRFLOW OUT VENT \ AIR LOAD DOOR SHUTTER (OPEN) NAT RAL 'DRAT AIRFLOW R BURNERS I PI LOT Gas: Nat. Gas @ J.C. pressure at rated flow. (,L.P.G. @ 13" W.C. pressure). 120 VAC, 1�, 60 HZ, 9.AMPS. Electric: 208/240/480 VAC, 36 60 HZ, power as, specified for model plus 120 VAC, 10, 60 HZ, 9 AMPS. (In Canada, one service only) INSTALLATION: A factory technician or factory authorized installation technician MUST supervise and approve any installation. SPECIFICATIONS, REVOLVING TRAY OVEN. The successful bidder shall furnish revolving tray type oven in accordance with preceding ordering data and with these spec ific..*.ions. Oven shall be complete with trays, driving mechanism, electric motor, thermostat, valves, dampers, controls, switches, tray indicator dial, protected removable interior oven lights, factory prewiring setup, and with all standard equip: nnt. Oven shall be standard product of manufacturer, modified as necessary to ceet standards cited below. To assure standards of quality, the following shall be considered essential require- m,ants: Vertically -rising, counterbalanced loading door, with heat resistant obser tion panel in each door. Door to be hollow and with external vent holes for ventilation, ar_d Aerating in connection with door Ner_t, concealed in front of oven, which shall automatically oxen when door is opened. Door exterior to be stainless steel. There shall be two interlocEed doors on ovens with trays more than 110". 2. Dual vent system, with flues imbedded in oven walls, venting from near bottom of oven, plus top quick -cooling vent with damper. 3. Grade X diatomaceous silica (Celite) insL;iation, Oven to be insulated at time of erection. Prepacked sections not acceptable. 4. La°rge worm gear machine cut, securely keyed and clamped to main shaft, operating in oil bath, turned by high carbon steal worm, shall be used for drive. Transmission to be through speed reducer with clutch connections. Main bearings to be mounted outside oven chamber. S. Flexible type oven trays with stabilizer rings and levelizers at BOTH ends with support truss 'rods, and with automatically self-adjusting tray arms connect- ing spiders to stabilizer rings at both ends. Rings shall have diameter equal to or larger thsn diameter of reels. 6. Fast -turning emergency hand crank for emergency. unloading. 'It must be possible to turn handwheel with ease and to rotate trays £nszer than normal motor operation in case of power failure. Crank shall be located at front of oven so operator can see trays as they reach unloading position. 7. Interior walls of aluminized steel which shall not be painted. 8. Spiders of welded tubular construction, radiating from larger diameter steel discs of at least 1/2" thickness. 9. Framework of I -beams and channels completely separate from oven,walls, inner and outer. Framework shall carry entire load of main shaft, spiders and loaded trays direct to foundation. No wall shall have any weight -carrying function. 10. Main shaft and stub .shaft assembly with machined flanges welded and machined and assembled by large heavy machine bolts. PLAN VIEW T- #--3 Clear In front. of c«wral pm _�'Elecl. control Das on elect. Mated oven astir I ® `ty —Goc1 etmw C 4 Nocnln«r—� uo () / FROINT ELEV. ept •�urypppl Nd a and epulPwalw. :ARTH HT. At I ra AY[ x' rfrr0 SIZE No. OF TRAYS TRAY A -OVEN LENGTH WIOTH FN Cr OVEII :PSEE-0-01A. DEPTH HEIGHT IF WX BTV; %FP0.OXIMATE FLU•VNT SATING NSTALLEO WT. 4TB .4 37 62 82 76 1 29 6 64,000 ' 2_900 4712 4 56 BI 02 16 3844 6 126,000 3,424 4T 16 4 74 99 Il 00" j) Il 47,4 42, N iF7,000,— -4,020-- 4T20 4 I 117 B2 76 FROINT ELEV. ept •�urypppl Nd a and epulPwalw. :ARTH HT. At I ra AY[ x' rfrr0 SIZE No. OF TRAYS TRAY A -OVEN LENGTH WIOTH FN Cr OVEII :PSEE-0-01A. DEPTH HEIGHT IF WX BTV; %FP0.OXIMATE FLU•VNT SATING NSTALLEO WT. 4TB .4 37 62 82 76 1 29 6 64,000 ' 2_900 4712 4 56 BI 02 16 3844 6 126,000 3,424 4T 16 4 74 99 82 76 47,4 6 iF7,000,— -4,020-- 4T20 4 92 117 B2 76 S6Vi _ 6r 20BCA Oa 6 1 S 5T 10 S 37 62 91 BS 29 6 IW_7000 _ 3,260 ST 18 5T20 3725 B 5 S 56 74 92 61 99 117 91 91 91 85 83 85 3814 47% 66h 6 6 6 130,000 3,925 208,000-'{ 4,595 260 000 �185 6712 6T 18 6 6 37 56 62 at 100 100 - 94 94 - -3854 29 a 8 -_ 125,000 '5,950 wv0� 4,690 6774 6 74 99 100 94 1754 e , -- ?S�,000J..5,395 6T30 6 92 117 100 6 312 000 ( 6 5 7 T 14 7 31 62 109 B .141000 4450 7T21 7 56 81 109 A10329 B 22 000 5250 7T2e 7 T4 99 109 B ?9C 6,000 77357 92. 117 109 a 363 000 8,760 1. DESIGNED FOR INSTALLATION UPON LEVEL CONCRETE FLOOR WITH NO WOOD OR UTILITIES UNDER OVEN AREA (gofer fit facfarr for woad fI*ff frololloflan PrICS and dah; 2. PIPE LINE SIZE MUST BE SUFFICIENT TO DELIVER 125% RATED BTU AT V WATER CALUA4N PRESSURE, FOR FAST WARN Lop.(B7U RaWm_9oee nar Indlcdte con Unuau. Isom ) 3. AVOID EXCESSIVE ROOM AIR EXHAUST (Or JAS1011 flu• blower'nralkiM CA oarlonol oval 4. CLEARANCE NOT REWIRED AT SIDES OR BACK OF OVEN. 3. ALL SERVICE AND UTILITY CONNECTIONS TO OVEN BY CUSTOMER. 6. MSTALLATION HELPERS' TWO ON 4 OR3 TRAY -THREE ON 6OR7 TRAY. (Refer to CHUB for nalDg�t9lpiJ•Mn ruDDH focforr 1 7. DIMENSIONS SU8JECT TO CHANGE UNLESS CERTIFIED. S. STANDARD OVER SNIPPED WITH FULL SIZE WALL SZCTIONS. fRef« fo foyw if fafj( wall Is reaulred for nerNcted entrance.) 9. MR APPROXIMATE KJ[ RATING OF ELECT. 'HEATED OVEN$ MULTIPLY N' OF GUN PANS BY 2.5. O 2' HIGH FLIIE/VENT COLLAR: OD 1/2' STEAM CONNECTION: STEAM PIPE NOT SUPPLIED AS STANDARD EQUIPMENT. COINCOM140IIOr-IQ ELECTRICAL. MAS INLET: SEE NOTE N'.2 ABOVE. CHUBCO (6. J. CNUetucr CO.. INC.) NIe 14 S T a 6 6 T OA ICL AN O. CALIF. MM JR. DIMENSION SHEET C G ..R ...... aa� A DA SY .ar] SUIS . NONE Or" NO. e 6 I f I O N S W OATS CNZ'D. CInCD. W RATS .APR 12,1971 C-8112 The )lid d1ebf:J1(ir.,h(d1 R(port Our. Trial Balloon concerning interest in periodic releases of technical data for consultants has brought a gratifying response. This, our first such Report, is being mailed to all the original list. If there is a return card enclosed, it means we did not - have a response from yo.0 after our original letter. If you wish to be on the list for future Reports, return this to us. Tliis first issue is devoted to the subject most requested on the return cards: Ventilation. Note these sheets are punched for insertion in your M -M binder. .... we. will be inost pleased to have comments from you as to the usefulness of these Reports, and topics you would like to see covered in the future. . 0000®ee®000eo®®ooeee0o®o®®®o TIPS ON VENTILATION OF MECHANICAL OVENS NEGATIVE PRESSURE. First, a warning against the most common of all ventilating errors: the condition of ncbative pressure, which simply means more air is being exhausted than is being replaced. It happens especially in kitchens and bake shops with powerful exhaust fans and no causing pressure inside the room to be l than outside. It can cause personal discomfort and extreme oven malfunction. Draft is reversed, pull- ill- downward rather than upward, resulting in poor baking; improperly burned gas, heat baCkUp c�using' damage to controls, even explosions. Com- pensating air MUST be brought into the room.- (American oom:(American Gas Association offers, for 50¢ a copy, an excellent pamphlet on this subject, titled "Commercial kitchen Ventilation.") TOP VENTING. Cheaper ovens on the market ob- tain ventilation and draft from a simple hole in top of oven chamber. Even when top -vented ovens have baffles to restrict the straight -through flow of heat, moisture and steam, -they still have characteristically dryer bake, greater product shrinkage and higher fuel or power consumption. Middleby-Marshall ovens have a sophisticated/ tlnnhle-vent system. CUE ere are two vent outlets at�top,�nefor operatorortthe other, leading of oven chamber, for corn us r COOLING_ VENT. On M -M ovens, the vent outlet to- ward front (see sketch) connects to oven loading door. It cools door when closed, and prevents heat blast in operator's face when door is. open. When practical, this outlet should be vented separately from combustion outlet. When.impractical, they can be elbowed together, but connection should be above the restricting damper. Flow from this should be unrestricted for maximum operator comfprt. / COMBUSTION VENT. Cheaper ovens get secondary air as best they can, usually from air leakages at burner or loading doors. M -M ovens have exclu- sively designed secondary air boxes fabricated from steel, providing a positive source. The ovens are then vented from slots near bottom of oven chamber. Air is drawn through flues concealed in oven walls, across top of oven to center top outlet. This outlet, should be dampered to .04 to .06, as measured by draft gauge in top stack outlet, in a direct fired oven, and about .06 to .08 in indirect - fired ovens. There is a damper in top of oven c}1am.bcr .;.ening directly into the outlet, Which Is kept closed except when quick cooling of oven is wanted. D®AMARAL ASSOCIATES L JUL l > 19 8,3 June 3UM98SPECTION DEPARTMENT CITY. OF CUPERTINO City Of Cupertino Building Department Dear Sirs: This letter concerns current handicap regulation compliance for the project located at 10889 South Blaney Ave., Jack and Jill's Bakery. The bathroom configuration shown,on'the current floor plan. is as existing. To change the dimensions of the bathrooms as to fully comply with current regulations would be too costly and far more expensive than the initial project altogether. Grab bars and self closing doors (2-8 x 6-8) will be.provided. Si Robert Do Amaral One Hundred One Church Street Suite 4 Los Gatos CA 95030 (408)354-5878