Loading...
B-2017-1005 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2017-1005 931 NEW HAVEN CT CUPERTINO,CA 95014-4023(356 11 046) SOLARCITY CORPORATION SAN MATEO,CA 94402 OWNER'S NAME: LEY TOMAS J AND SILVIA B TRUSTEE DATE ISSUED:06/26/2017 OWNER'S PHONE: PHONE NO:(650)963-5100 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C10 C46 Lic.#888104 • Contractor SOLARCITY CORPORATION Date 12/31/2018 X BLDG X ELECT _PLUMB MECH X RESIDENTIAL_COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N)16-PANEL ROOF MOUNTED PV SYSTEM(4.8 KW);(N)LOAD •I hereby affirm under penalty of perjury one of the following two declarations: CENTER(125 AMPS);(N)BATTERY BACK UP i. I have and will maintain a certificate of consent to self-insure for Worker's REV#1 UPGRADE PANEL(200 AMPS)-ISSUED 9/28/2017 ,,,,t .ensation,as provided for by Section 3700 of the Labor Code,for the .erformance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$18000.00 !. APPLICANT CERTIFICATION I certifythat I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: ' and state laws relating to building construction,and hereby authorize 356 11 046 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)•agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED. may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regula'ons •-r,the Cu.ertino Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. • IT re ��n� :`� Date 9/28/2017 Issued by:Abby Ayende Date:06/26/2017 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is ' 1. I,as owner of the property,or,my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business'&Professions Code) ' 2. I,as owner of the property,'am exclusively contracting with licensed Signature of Applicant: contractors to construct the project(Sec.7044,Business&Professions Code). Date:9/28/2017 Thereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER t. I have and will maintain a Certificate of Consent to self-insure for Worker's - - Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. 'I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code, ec' 5505 25533,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall �, 4� be deemed revoked. Owner or auto &' -d agent: �T�!7P APPLICANT CERTIFICATION Date: • 2: Air I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply.with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. I understand my plans shall be used as public records. Licensed Signature Date 9/28/2017 Professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO,CA 95014-3255 • i 441.:rssa Q (408)777-3228 • building@cupertino.org PEMIT#B-`-?-2.0(1 - it9OS CUPERTINO REV# 1 DEF# ❑ NEW CONSTRUCTION El ADDITION ALTERATION 111 T.I. CI MEP ❑RE-ROOF ❑SWIMMING POOL/SPA PROJECT ADDRESS n �c I l v& / 1 APN# t t (t.) - OWNER NAME .�1 (Y L IACy L K/� PHONE/( E-MAIL STREET ADDRESS 4A, rCITY, STATE,ZIP e,r,-;1 n -of 6A q661(4 [CONTRACTOR NAME ❑OWNER-BUILDER COMPANY NAME 11�r \j-ko N Q LICENS NUMBER LI� TYPE OS L giaq 64G 3 ISTREET ADDRESS / I ; CITY,STATE, ZIP C....30%, �� I, /�f \ ' ^ I E-MAIL /rU\ 1\ PHONE eArN( � BUS.LIC 8 � C ,f�` y1�/L ,II - - Occ-e,5 cov40 ,ce.5 6,.G6sr‘ 71.62 ryAO?- 3v)--) . ❑ARCHITECT ❑OWNER ❑OWNER AGENT Cl CONTRACTOR AGENT El ENGINEER 0 DEVELOPER Cl TENANT • CONTACT NAME E-MAIL STREET ADDRESS CITY,STATE,ZIP PHONE ' C TON M Mon c\I\ Le, kos .-z) 200 0.�l\ mo:,; _ ►. , - , - /c/y\ 1 2C-Zc Ce„ "I a geSM 1- —ib1 - 1 s ❑SINGLE-FAMILY/DUPLEX Cl MULTI-FAMILY D INDUSTRIAL 0 COMMERCIAL EXISTING USE EXISTING SF NEW FLOOR SF PORCH SF DECK SF DEMO SF STORIES# TOTAL NET SF USE TYPE OCC SQ.FT. VALUATION($) REMODEL REMODEL KITCHEN REMODEL OTHR GARAGE Cl ATTACHED BATHROOM SF SF SF SF ❑DETACHED EXISS SPRINKLERS ClNO ❑EICHLER ❑No SECOND STORY ADDITION ❑YES FIRECl NO DWELLING SECOND DWELLING ❑YBs 0 ATTACHED 0 DETACHED OTHER UNITS it UNIT ADDITON: , ❑NO S F POOLS' ❑FIBERGLASS ❑VINYL-LINED ❑GUNITE ❑PREFABRICATED 1 POOL-SF SPA-SF I SPA ATTACHED❑YES 0 NO TOTAL-SF ' i i EIVED BY: i TOTAL VALUATION: Commercial or Multi-Family Buildings with Public Swimming Pools requires Department of Environmental Heath approval I 6 ) RE-ROOF EXISTING ROOF TYPE: ❑BUILT-UP ROOF❑ASPHALT SHINGLES❑WOOD SHAKES❑WOOD SHINGLES❑TILE OTHER(SPECIFY) REMOVE/REPLACE❑NO IF NO PLYWOOD ❑1- D 3/8" PLYWOOD TYPE:. PITCH: ROOF CLASS ❑YES I II OF LAYERS THICKNESS I=15/8" OTHER El OSB I=1 CDX OTHER •12 A • PROPOSED ROOF TYPE:❑BUILT-UP ROOF DASPHALT SHINGLES Cl WOOD SHAKES❑WOOD SHINGLES 0 OTHER *Provide a signed copy of the Cupertino's Tear-Off Policy • SF - #of SQUARES By my signature below I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided-is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to ' enter the above-identified property for in..ec:in p %•--- to .os- . I acknowledge and authorize all informationcontame lon this application form to be made available for public record. 1 „di�;r• 22 ✓Il Signature of Applicant/Agent: ;ilr s'=.tts.�� Date: L .. f SUPPLEMENTAL INFORMATION REQUIRED *New SFD/Second Dwelling Units/Multifamily Dwellings:A Demolition permit is required prior to issuance of a building,permit for all new construction. , *Commercial Buildings: Provide a completed Hazardous Materials Disclosure form if any Hazardous Materials are beingusedas part of this project. - *Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. *HOA-Provide a letter of approval from the Home Owner's Association BldgApp_2017.doc revised 08/01/17 • I CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-1005 931 NEW HAVEN CT CUPERTINO, CA 950144023 (356 11 046) SOLARCITY CORPORATION SAN MATEO, CA 94402 OWNER'S NAME: LEY TOMAS J AND SILVIA B TRUSTEE OWNER'S PHONE: 408-768-4433 LICENSED CONTRACTOR'S DECLARATION License Class C-10: C-46 Lic. #888104 Contractor SOLARCITY CORPORATION Date 12/31/2018 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the CTperformance of the work for which this permit is issued. - I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulatio s per the Cup unicipal Code, Section 9.18. Signatu air Date 6/26/2017 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) z. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 6/26/2017 DATE ISSUED: 06/26/2017 PHONE NO: (650) 963-5100 BUILDING PERMIT INFO: X BLDG X ELECT _ PLUMB _ MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: (N) 16 -PANEL ROOF MOUNTED PV SYSTEM (4.8 KW); (I) LOAD CENTER (125 AMPS); (N) BATTERY BACK UP Sq. Ft Floor Area: I Valuation: $18000.00 APN Number: Occupancy Type: 356 11046 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Abby Ayende Date: 06/26/2017 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 6/26/2017 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cu tino Municipa de, Chapter 9.12 and the Health &Safety Code ec 'ons 25505, 25 33, and 34. Owner or authorized agent: Date: 6/26/2017 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CUPERTINO 3-701�+- 100:,5 ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • ^:�°„� ^ .a „ J.c:: AE PROJECT ADDRESS q3 I - /AUC. , „ ( /"'f— V `J 1 / (� f`j -O -NE/ /l APN # 3� �' I , IV �Jj�IL�( OWNERNAME "�r, j n G PCH E , STREET ADDRESS CI== FAX CONTACT NAME Gerry Igtanloc PHGN`650-759-8042 E Lgigtanloc@solarcity.com ST'REETADDRESS391 Foster City Blvd. CITY, STATE, "'Foster City, CA, 94404 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT A CONTRACTOR ❑ CONTRACTOR AGENT11ARCHITECT 11ENGINEER ❑ DEVELOPER 11TENANT CONTRACTOR NAME SolarCity Corp. LICENSENUMBER888104 LICENSE TYPECI0,C46 BUS. LIC #28844 COMPANYNAMESolarCity Corp. E-MAILLgigaCC77nloc@solarcity.com FAX STREETADDRESS3055 Clearview Way c''" ,"San Mateo, CA 94402 PHDNE650-759-8042 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL ¢ FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF Q SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND PROJECT URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD IN ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FDR SOLAR PANELS: NUMBER OF PANELSIUNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: o N DESCRIPTION OF WORK Install ( (j) rooftop mounted solar panels,( Lj .) KW G, co c& -N i ere RECEI'.'ED BY: By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I ha a read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to ilding constructiOn. t1btho{ a representatives of Cupertino to enter the above-ifentified pr9peIty for inspection purposes. Signature of Applicant/Agent: L -L3 Date: 7 SUPPLEMENTAL INFORMATION REQUIRED t OFFICE USE ONLY ❑ OVER-THE-COUNTER x ❑ &YPRFSS U STANDARD U C LARGE a. ❑ MAJOR SEAN HATCH 09/28/17 09/28/17 B-2017-1005 Jasmine Archbold SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 (N) (N) SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 SEAN HATCH 09/28/17 INDEX ABBREVIATIONS VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * * * * * * * * * * * * * * * LICENSE GENERAL NOTES ELECTRICAL NOTESELECTRICAL NOTES Abby Ayende 06/26/17 3' FSB 3' FSB 3' FSB A (E) DRIVEWAY Unlocked Gated Unlocked Gated Pitch 4/12 MP1 Scale: 3/32" = 1' SITE PLAN 0 1' 10' 21' MP1 18 196 18 196 Comp Shingle 2 Stories LEGEND Abby Ayende 06/26/17 Scale: 1 1/2" = 1' STANDOFF S1 S1 SIDE VIEW OF MP1 NTS X-SPACING PORTRAIT LANDSCAPE STORIES: ROOF AZI X-CANTILEVER Y-SPACING Y-CANTILEVER PITCH ARRAY AZI PITCH NOTES X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. MP1 196 18 196 18 Comp Shingle 2 2x4 @ 24" OC 2x4 @24" OC 72" 24" 39" 0" 48" 20" 0" 64" TOP CHORD BOT CHORD A Abby Ayende 06/26/17 Abby Ayende 06/26/17 LICENSE MODULE SPECS INV 1 INVERTER SPECS GENERAL NOTES MAIN PANEL SPECS GROUND SPECS INV 2 INV 3 AC DC V 240 L2 L1 N EGC/ GEC GND N ADJUST MIN. ACTIVATION VOLTAGES! Inverter 1 IND EGC DC- DC+ DC- DC+ A EGC DC- DC+ MP1: 1x8 EGC DC- DC+ MP1: 1x8 Vstart = 200V Vstart = 200V A POI 1 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC 1 2 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC 2 3 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC 3 4 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC 4 5 Vmp = VAC Imp= AAC 5 GEC E 8 E 7 7 8 N EGC L2 L1 C 6 N EGC L2 L1 C 6 D 6 C D Abby Ayende 06/26/17 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 931 New Haven Ct OPERATING VOLTAGE = 240V JB-9508889-00 Abby Ayende 06/26/17 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)-SOL-CITY (765-2489) www.solarcity.com LB-130089-10X Per Code: CEC 690.31.G.3 Label Location: (C)(IC)(CB) LB-050081-10X Per Code: CEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: CEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: CEC 690.5(C) Label Location: (INV) LB-050082-10X Per Code: CEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: CEC 690.54 Label Location: (AC) (POI) LB-040013-10X Label Location: (AC) LB-070005-10X Per Code: CEC 690.17.E Label Location: (DC)(CB) LB-060046-10X Per Code: CEC 690.54; CEC 690.17 Label Location: (POI) LB_040108_10X Per Code: CEC 690.56(C) Label Location: (INV) LB-040009-10X Per Code: CEC 705.12.D.3 Label Location: (POI) LB-070039-10X Per Code: CEC 705.12.D.2.b Label Location: (POI) LB_200127_10X Per Code: CEC 705.12.D.2.c LB-070016-10X Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED Label Location: (DC)(INV)(CB) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set Abby Ayende 06/26/17 BACKUP LOAD CENTER Label Location: Backup load Center (BLC) Per Code: NEC 408.4 Label Location: Back up load Center (BLC) Per Code: NEC 220 Label Location: Main Panel Per Code: NEC 312.8(3) STORAGE SYSTEM LABELS CAUTION DO NOT ADD NEW LOADS CAUTION THIS PANEL HAS SPLICED FEED- THROUGH CONDUCTORS. LOCATION OF DISCONNECT AT ENERGY STORAGE BACK UP LOAD PANEL Label Location: Main Panel Per Code: NEC 705.12.D.2.3.b WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Label Location: Main Panel Per Code: NEC 705.12.D.3 CAUTION DUAL POWER SOURCE SECOND SOURCE IS ENERGY STORAGE SYSTEM Label Location: Main Panel Per Code: NEC 705.12.D.2.3.c WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. Label Location: Service Disconnect ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALL ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHT ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALL ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDE Label Location: Service Disconnect Label Location: Service Disconnect Label Location: Service Disconnect Abby Ayende 06/26/17 − − − − −  Z 8UVCTV  8 ű8 − − − − Abby Ayende 06/26/17 5,00% 10,00% 15,00% 20,00% 25,00% 30,00% 35,00% 40,00% 45,00% 50,00% 55,00% 60,00% 65,00% 70,00% 75,00% 80,00% 85,00% 90,00% 95,00% 100,00% 215 250 300 345 400 480 [%] of Rated PowerMPPT Voltage [V] 97,0 96,6 96 94,8 94,4 95,2 94 93,6 93,2 92,8 92,4 92 91,6 95,6 97,0 96,4 96,4 96 95,2 96 95,2 96,2 96 94 94 92 92 92 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%'HƂEKGPE  QH 4CVGF 1WVRWV 2QYGT IN1 IN2 + - + - IN1 + - IN2 + - MPPT 2 (DC/DC) MPPT 1 (DC/DC) BULK CAPS INVERTER (DC/AC) LINE FILTER GRID PARALLEL RELAY L1 L2 PE RESIDUAL CURRENT DETECTION DC/DC DSP CONTR. DC/AC DSP CONTR. μP CONTROL CIRCUIT RS485 + T/R - T/R RTN REMOTE CONTROL* + R - R ALARM N.C N.O C GROUND FAULT DETECTION N IN1 IN2 + - + - DC AFDI IN1.1(+) IN1.2(+) IN1.1(-) IN1.2(-) IN1 IN2 + - + - IN2.1(+) IN2.2(+) IN2.1(-) IN2.2(-) IN1 IN2 + - + - WIRING BOX IN1 IN2 + - + - Abby Ayende 06/26/17 HDFK SURGXFW 7KH HQGXVHU GRFXPHQWDWLRQ VKLSSHG ZLWK =HS 6RODU¶V SURGXFWV FRQVWLWXWHV WKH VROH VSHFL¿FDWLRQV UHIHUUHG WR LQ WKH SURGXFW ZDUUDQW\ 7KH FXVWRPHU LV VROHO\ UHVSRQVLEOH IRU YHULI\LQJ WKH VXLWDELOLW\ RI =HS6RODU¶V SURGXFWV IRU HDFK XVH 6SHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH 3DWHQWV DQG $SSV ]VSDWVFRP IRU FRPSRVLWLRQ VKLQJOH URRIV DQ\ PDQXIDFWXUHU FHUWL¿HG DV ³7\SH ´ RU ³7\SH ´ 6SHFL¿FDWLRQV HDFK SURGXFW 7KH HQGXVHU GRFXPHQWDWLRQ VKLSSHG ZLWK =HS 6RODU¶V SURGXFWV FRQVWLWXWHV WKH VROH VSHFL¿FDWLRQV UHIHUUHG WR LQ WKH SURGXFW ZDUUDQW\ 7KH FXVWRPHU LV VROHO\ UHVSRQVLEOH IRU YHULI\LQJ WKH VXLWDELOLW\ RI =HS6RODU¶V SURGXFWV IRU HDFK XVH 6SHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH 3DWHQWV DQG $SSV ]VSDWVFRP 1H[W/HYHO 39 0RXQWLQJ 7HFKQRORJ\ ]HSVRODUFRP 3DUW 1R  /LVWHG WR 8/  &DSWXUHG :DVKHU /DJ 3DUW 1R     )ODVKLQJ ,QVHUW 3DUW 1R  /LVWHG WR 8/  $UUD\ 6NLUW 3DUW 1R  RU  /LVWHG WR 8/  3DUW 1R  RU  /LVWHG WR 8/  (QG &DS 3DUW 1R /  RU  5  RU  '& :LUH &OLS 3DUW 1R  /LVWHG WR 8/  *URXQG =HS 9 3DUW 1R  /LVWHG WR 8/  DQG 8/  ,QWHUORFN 3DUW 1R  RU  /LVWHG WR 8/  /HYHOLQJ )RRW 3DUW 1R  /LVWHG WR 8/  Abby Ayende 06/26/17 ® ® ® ® Abby Ayende 06/26/17 0~+5W POSITIVE POWER TOLERANCE 60 CELL MONOCRYSTALLINE MODULE 275-305W POWER OUTPUT RANGE 18.6% MAXIMUM EFFICIENCY IEC61215/IEC61730/UL1703/IEC61701/IEC62716 ISO 9001: Quality Management System ISO 14001: Environmental Management System ISO14064: Greenhouse gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System Comprehensive Products And System Certificates Mono Multi Solutions Certified to withstand the most challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load • 35 mm hail stones at 97 km/h Standard Step Warranty Trina Linear Warranty Additional value from Trina Solar’s linear warranty Guaranteed Power 80% 90% 100% 97% Years 5 10 15 20 25 LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty · 25 Year Linear Power Warranty Maximize limited space with top-end efficiency • Up to 186 W/m² power density • Low thermal coefficients for greater energy production at high operating temperatures Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyond certification requirements • PID resistant • 100% EL double inspection EU-28 WEEE COMPLIANT RECYCLABLE PACKAGING Founded in 1997, Trina Solar is the world's leading comprehensive solutions provider for solar energy. we believe close cooperation with our partners is critical to success. Trina Solar now distributes its PV products to over 60 countries all over the world. Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners. THE MODULE I-V CURVES OF PV MODULE(305W) Voltage(V) Current (A) 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 1000W/m² 800W/m² 600W/m² 400W/m² 200W/m² FRAMED 60-CELL MODULE TSM-DD05A.18(II) 280-305W PRODUCTS POWER RANGE CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. © 2017 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice. Version number: TSM_EN_2017_A www.trinasolar.com P-V CURVES OF PV MODULE(305W) Voltage(V) Power (W) 50 100 150 200 250 350 300 1000W/m² 800W/m² 600W/m² 400W/m² 200W/m² ELECTRICAL DATA (STC) STC: Irradiance 1000W/m², Cell Temperature 25°C, Air Mass AM1.5. *Measuring tolerance: ±3%. Peak Power Watts-PMAX (Wp)* Power Output Tolerance-PMAX (W) Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) Module Efficiency m (%) 0 ~ +5 305 32.9 9.28 40.2 9.72 18.6 290 32.2 9.01 39.5 9.50 17.7 295 32.5 9.08 39.7 9.55 18.0 300 32.6 9.19 39.9 9.64 18.3 275 31.4 8.76 38.7 9.26 16.8 280 31.7 8.84 39.0 9.35 17.1 285 31.8 8.97 39.3 9.45 17.4 (DO NOT connect Fuse in Combiner Box with two or more strings in parallel connection) 44°C (±2°C) - 0.39%/°C - 0.29%/°C 0.05%/°C TEMPERATURE RATINGS NOCT(Nominal Operating Cell Temperature) Temperature Coefficient of PMAX Temperature Coefficient of VOC Temperature Coefficient of ISC MAXIMUM RATINGS Operational Temperature Maximum System Voltage Max Series Fuse Rating -40~+85°C 1000V DC (IEC) 1000V DC (UL) 15A (Please refer to product warranty for details) WARRANTY 10 year Product Workmanship Warranty 25 year Linear Power Warranty PACKAGING CONFIGURATION Modules per box: 30 pieces Modules per 40’ container: 840 pieces NOCT: Irradiance at 800W/m², Ambient Temperature 20°C, Wind Speed 1m/s. ELECTRICAL DATA (NOCT) Maximum Power-PMAX (Wp) Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) 209 29.4 7.10 36.3 7.55 212 29.6 7.17 36.6 7.63 216 29.9 7.23 36.7 7.67 227 30.6 7.42 37.3 7.84 220 30.2 7.28 36.9 7.71 223 30.4 7.35 37.1 7.78 205 29.2 7.02 36.0 7.48 Solar Cells Cell Orientation Module Dimensions Weight Glass Backsheet Frame J-Box Cables Connector Fire Type MECHANICAL DATA Monocrystalline 156.75 × 156.75 mm (6 inches) 60 cells (6 × 10) 1650 × 992 × 40 mm (65.0 × 39.1 × 1.57 inches) 19.6 kg (43.1 lb) 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass White Black Anodized Aluminium Alloy IP 65 or IP 67 rated Photovoltaic Technology Cable 4.0mm² (0.006 inches²), 1000 mm (39.4 inches) MC4 UL 1703 Type 2 for Solar City DIMENSIONS OF PV MODULE(mm/inches) 992/39.1 1650/65.0 A 941/37.0 180/7.1 150/5.9 990/39.0 330/13.0 12-Drain Hole 1200/47.2±10/0.39 Junction Box Nameplate 6-Ø 4.3 Grounding Hole 4-Ø 9x12 Installing Hole A Back View 40/1.57 40/1.57 35/1.38 40/1.57 11/0.43 Silicon Sealant Laminate Frame (A-A) Abby Ayende 06/26/17 TESLA.COM/ENERGY Tesla Powerwall 2 is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, load shifting, backup, and off-grid use. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 208 V, 220 V, 230 V, 100/200 V, 120/240 V Feed-In Type Single & Split Phase Grid Frequency 50 and 60 Hz Total Energy1 14 kWh Usable Energy1 13.5 kWh Real Power, max continuous2 5 kW (charge and discharge) Real Power, peak (10 s)2 7 kW (discharge only) Apparent Power, max continuous2 5.8 kVA (charge and discharge) Apparent Power, peak (10 s)2 7.2 kVA (discharge only) Imbalance for Single-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor (full-rated power) +/– 0.85 Depth of Discharge 100% Internal Battery DC Voltage 50 V Round Trip Efficiency1,3 > 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C Operating Humidity (RH) Up to 100%, condensing Maximum Altitude 3000 m Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Noise Level @ 1m < 40 dBA at 30°C COMPLIANCE INFORMATION Safety UL 1642, UL 1741, UL 1973, UL 9540, UN 38.3, IEC 62109-1, IEC 62619, CSA C22.2.107.1 Grid Standards Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003, EN 61000 Class B Environmental RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, 2006/66/EC Seismic AC156, IEEE 693-2005 (high) MECHANICAL SPECIFICATIONS Dimensions 1150 mm x 755 mm x 155 mm Weight 125 kg Mounting options Floor or wall mount 1 Values provided for 25°C, 3.3 kW charge/discharge power. 2 Values region-dependent. 3 AC to battery to AC, at beginning of life. 4Optional BACKUP GATEWAY SPECIFICATIONS Dimensions 691 mm x 378 mm x 129 mm Weight 16.4 kg Disconnect Current 200 A Enclosure Type NEMA 3R Ingress Rating IP44 Overcurrent Protection Breaker4 100–200 A User Interface Tesla App Connectivity Wi-Fi, Ethernet, 3G4 AC Meter Revenue grade Operating Modes Support for solar self-consumption, load shifting, backup, and off-grid use Backup Operation Automatic disconnect for seamless backup transition Modularity Supports up to 10 AC-coupled Powerwalls Abby Ayende 06/26/17 TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS PARTIAL HOME BACKUP WHOLE HOME BACKUP Solar Whole home backup Backup Gateway Solar inverter Powerwall Utility meter Optional Distribution board Distribution board Sub board Solar Home loads Solar inverter Utility meter Backup Gateway Powerwall Backup loads Optional EN - BACKUP - 2017-03-27 Abby Ayende 06/26/17