Loading...
15050100CITY OF CUPERTINO BUILDING PERMIT I BUILDING ADDRESS: 10605 FARALLONE DR I CONTRACTOR: SOLARCITY I PERMIT NO: 15050100 OWNER'S NAME: SCOTT & SABRINA ELLIS 13055 CLEARVIEW WAY I DATE ISSUED: 05/18/2015 OWNER'S PHONE: 4082529303 I SAN MATEO, CA 94402 I PHONE NO: (650) 638-1028 LICENSED CONTRACTOR'S DECLARATION License Class Lic. H )?2rp to Contractor Date r I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which in accrue against said City in consequence of the granting of this permit. Ad it' nal , e applicant understands and will comply— with all non -point source r� lati n er the Cupertino Municipal Code, Se 9 18. Signature � Date ©s ❑ OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9 18. Signature Date JOB DESCRIPTION: RESIDENTIAL Q COMMERCIAL INSTALL 21 ROOF TOP, FLUSH MOUNTED PV MODULES (5.46 KW) Sq. Ft Floor Area: I Valuation: $11000 APN Number: 36939037 00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PE SUANCE OR 180 DAYS FR ED INSPECTION. I z //-'r All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Are Air I.ty Management District I will maintain compliance with the Cuperti Mu i pal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505 553 nd 25534. Owner or authorized agent: Date r CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's ARCHITECT'S DECLARATION 1 understand my plans shall be used as public records. Licensed CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION V 10300 T'ORRE AVENUE • CUPERTINO, CA 95014-3255 O (408) 777-3228 • Fr&X (108) 777-:-x333 • buildiriwd`-cuoertino.org \V7 00 AE PROJECT ADDRESS t :�EA:P:NN 6,l✓ raY0" L r->, D '2 .39 - o lam" v r. (/" / -:7- OWNER NAME L GCJ 1I y_ `1 PHOT y D� . 0 E-MAIL STREET ADDRESS.-C.t to -6c)-5 c)-5 GL1I G r1'e-,.- 1� �= 1 l/ b CITY, STATE, ZIP Ci -Y f (el O, C• O FAX CONTACT NANIE Marjan Javanmard PHONE 650.477.6430 1 E-MAILmjavanmard@solarcity.com STREETADDREss391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 944041F&X ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT - ❑ CONTRACTOR 19 CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAMESOIarCity Corporation LICENSENUNBER888104 LICENSE TYPE C10 BUS. LIC k28840 COMPANY NAMESOIarCity Corporation E-MAIL mjavanmard@solarcity.com FAX STREETADDRESS391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 PHONE 650.477.6430 ARCHITECT/ENGINFER NAME LICENSE NUMBER BUS. LIC H COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT M Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No STRUCTURE: ❑ ❑ SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS, NUMBER OF PANELS/UNITS: , p KILOWATTS (COMMERCIAL ONLY): CJ . l TOTAL VALUATION, ' �> C)(_) DESCRIPTION OF WORK Installation (- I) rooftop flush mounted solar panel -q6) kW Y By my signature below, I certify to each of the following: I am th roperty r or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I hav ead the e Iption of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I Ithoriz s tatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agenr Date: d 5 Z SUPPLE L INFORMATION RE I " 4i ray `� FFY" usE,oNiY+,t' O...t..,. . P ��( r} 1 �Y 8 h iuz �a l'��fvl fr tiif titl z l `✓� ,1" �>144 6 xll�y�} Elia ii -(� 1 y; Dr OYER TA)rCOUN'pE'y�R s �1f� _ � � Ui r d� Z� ❑ ` �� } � } rLARGC •NIAJOR ' PVApp_2011.doc revised 03116111 CITY OF CUPERTINO ISI FEE ESTIMATOR — BUILDING DIVISION ka,ADDRESS: 10605 FARALLONE DR DATE: 05/18/2015 REVIEWED BY: MELISSA F7 MW l Firs; APN: 369 39 037 BP#: `VALUATION: 1$11,000 'PERMIT TYPE:Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY USE: SFD or Duplex_T_ Phviihr hivp. Vve: PENTAMATION PERMIT TYPE: SOLAR -RE i WORK I INSTALL 21 ROOF TOP FLUSH MOUNTED PV MODULES 5.46 k SCOPE Suppl. Insp. Fee -.Q) Reg. Q OT �j .��.r.�,,.rm ,I..v �_. '� ;.`, �.. ,,t•.I f �.��.0 ff�'.. �. .� .�.t_,trz .�....� (� Ir 'Ju, Y' ll V�' f ! l;.li� i ll� i ;- nZ'i Alf' di. Pl;:rrr ('Fri:ck Phunb. 1'10r t_ d;wch Pier. I'l�,rrs Check F7 MW l Firs; f'lt,'rrt17. Pernaii feet. 1�1lec. Pe'rwif l'e'e: (.�i1;e r AlcrrFt. lrrs/,a. -1 1 (,Ir1 r Plarn7b lrtsp.0 01hei h1c, '. h7sp. 1'lecll, h7.5/7. i"trP: Phviihr hivp. Vve: % ec. Insp, Fee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School ni.trirt etc)_ These fees. are based an the nreliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff.' 711/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 0 # Alternative Energy System $236.00 IPHOTOVRES Photovoltaic System Suppl. PC Fee: Q Reg. Q OT k.0 I hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee -.Q) Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 C'r.ur:,7I.1 c! Ur, TO. :4J112ini-Qre'llivc 0 0 Work Without Permit? O Yes Q No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential E) Building or Structure 0 A iit:n : i 1)<,crrrr,,>rriritiCu9 1<' c -s: Strong Motion Fee: IBSEISMICR $1.43 Select an Administrative Item Bld.P Stds Commission Fee: IBCBSC $1.00 ' `{ SU°BTOTALS s .. $2.43 A," ` TOTAL'SE $236.00 $238.43 Revised: 05/07/2015 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10605 FARALLONE DR CONTRACTOR:SOLARCITY PERMIT NO: 15050100 OWNER'S NAME: SCOTT&SABRINA ELLIS 3055 CLEARVIEW WAY DATE ISSUED:05/18/2015 OW ER'S PHONE: 4082529303 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL ❑ INSTALL 21 ROOF TOP,FLUSH MOUNTED PV MODULES License Class Lic.# yyy t0 y (5.46 KW) Contractor 2<o l a,-(C-',A'\ Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$11000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36939037.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PE SUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FR ED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which m accrue against said City in consequence of the granting of this permit. Ad if nal a applicant understands and will comply with all non-point source r� lati n er the Cupertino Municipal Code,Se 9.18. _ IRE-ROOFS: Signature Date 05/j All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, wil I do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Ar Air lity Management District I performance of the work for which this permit is issued. will maintain compliance with the Cuperti Mu i pal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505 553 nd 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: permit is issued. Date I certify that in the performance of the work for which this permit is issued,l shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that 1 have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION L 0 COMMUNITY DEVELOPMENT DEPAR-rMENT• BUILDING DIVISION ig 10300-TORRE AVENUE•CUPERTINO, CA 95014-3255 O ,408)777-32_8 • FAX 4)8)777-3333 •b0d'Nngp5gupertino.org CUPERTINO I \ PROJECT ADDRESS to(, /�� h C F/x YCk I 1 v�l� 0�• APN# � � ' 59 OWNER NAME �� ' �l. 1 PHO�,fE�O �_ .] O„ E-MAIL Zj G ` t �7 STREET ADDRESS �af©� YCITY, STATE,ZIP _ FAX k7 L C )e 1✓1 Os Ce . fh 01 CONTACT NAME Marjan Javanmard PHGNE650.477.6430 E-MAILmjavanmard@solarcity.com STREETADDRESS391 Foster City Blvd CITY,STATE, ZIP Foster City, CA 94404 FAX ❑OWNER ❑ OWNER-BUII.DER ❑ OWNER AGENT ❑ CONTRACTOR IN CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME SolarCity Corporation LICENSE NUMBER 888104 LICENSE TYPE C10 BUS LIC g28840 COMPANY NAME SolarCity Corporation E-MAILmjavanmard@solarcity.com FAX STREETADDREss391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 P"'650.477.6430 ARC HITECTIENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF SFD or Duplex ❑ MUltl-Famlly PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO ❑SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER. FOR SOLAR PANELS: NUMBER OF PANELS/UNITS. . KILOWATTS(COMMERCIAL ONLY) 6. TOTAL VALUATION DESCRIPTION OF WORK Installation ( 1) rooftop flush mounted solar panel (5-,46) kW DB By my signature below,I certify to each of the following: I am th roperty or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I hav eadthe e Iption of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I thoriz s tatives of Cupertino to enter the above-identified +property for inspection purposes. Signature of Applicant/Agent: Date: 0'5 / 1$ SUPPLE L INFORMATION REOMED OFFICE USE ONLY W ❑ OVER-THE-COUNTER F ❑ EXPRESS U x STANDARD El U LARGE a MAJOR PVApp_2011.doe revised 03/16111 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION ADDRESS: 10605 FARALLONE DR DATE: 05/18/2015 REVIEWED BY: MELISSA APN: 369 39 037 BP#: *VALUATION: j$11,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORK INSTALL 21 ROOF TOP FLUSH MOUNTED PV MODULES 5.46 k SCOPE El NOTE. This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 E ..' 7/1!13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: (E) Reg. OT 0.0 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee-.0 Reg. ® OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? Yes (F) No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential E) tr Building or Structure Strong Motion Fee: IBSEISMICR $1.43 Select an Administrative Item Bldy Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $2.431 $236.00 TOTAL FEE: $238.43 Revised: 05/07/2015 SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE L COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO ��" 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333• building(a.cupertino.org Permit No. &L' o-570 I v� Address /o(,Of eA14A'CUptE IVE, CUfE)(T)Na #of Alarms Smoke: 6 Carbon Monoxide: PERMIT CANNOT BE FINALED AND COMPLETED UNTIL�IIIS CERTIFICATE • '"�, �:"'"-, '- r 4 �?a:� ���_ '"� '�.. ,�,�.arx 3Y���;, cak.{ „1�^3tw��3'x'£w�.,,�"an..u.*f�°%€",'-.`=k,�'�' �R'�'k�,�a .,,i .. 3y, ��" � HAS BEE�I,SI �N .D' RFTiIRNFn��O'THE;BU�iD G€ ISI�Nx'� - � ` PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations,or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarm(s)may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes.The alarms have been tested and are operational, as of the date signed below. I have read and agree to comply W04 the terms and conditions of this statement Owner(or Owner Agent's) Name: / / Signature.,",.......` Date: L. �...; ....................................... Contractor Name: Signature...................................................................Lic.#......................................Date: ................... Smoke and CO form.doc revised 03/18/14 WATER-CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION FIL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUpERTINO :�` 2y (408)777-3228•FAX(408)777-3333• building(aDcupertino.or_q may' Owner Name .S U Tr EL_L 15 Permit No. Address fftt t-6r4t 091VE 64eatZr(tj o t CA 150 14- h PERMITl CANNOT BE FWALED'ANA CONi�LETED UNTIL THIS CERTIFICATE SHA E�..'IYD RST 1 DO H �IIaDII,tG`IIIO1�� Please refer to the attached California Civil Code Sections 1101.1—1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: rk Date: 5/2�1IS 9/'No Go to Question 2. 1 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip �the Lrest of the form. Owner' Signature: C�,,,,� - Date: 61Zelf [No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1�1y0�1..1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: fAzz, Date: 5/m/15- EKNo Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 11101.1..1,through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: SL S/` Date: <12V/�_ 13"Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. Q"�My propertyis a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or unprovements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or unprovements). ❑ My propertyis a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1,2014, specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019, all non-cornpliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or unprovements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1,2014, specified building alterations or unprovements shall require non-compliant — plumbing fixtures to be replaced with water-conserving plumbing fixtures. SB407 201 S.doc revised 02104115 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). IfWe,the owner(s)of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to datnpZcified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-conserving plumb' fixtures comply with the requirements as indicated in the table bel w. Owner's (or Owner Agent's) Signature: Date: Upon completing and signing this Certificate,please return it to the Building Division in order to final your pen-nit. Non-Compliant Water-Conserving Plumbing Fixture PlumbingFixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type 2013 CPC Ch. 4 2013 CPC Ch.4 2013 CPC Ch.4 Water Usage 2013 CALGreen Div.4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 /Flow Rate Single-Family Multi-Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume(the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets— Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets— Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown,it is not required to be upgraded. SB407 201 S.doc revised 02104115 1 CALIFORNIA CIVIL CODE SECTIONS 1101.1-1101.8 Civil Code Division 2. Property Part 4. Acquisition of Property Title 4. Transfer Chapter 2. Transfer of Real Property Article 1.4. Installation of Water Use Efficiency Improvements ........ 1101.1 — 1101.8 1101.1. The Legislature finds and declares all of the following: (a)Adequate water supply reliability for all uses is essential to the future economic and environmental health of California. (b)Environmentally sound strategies:to meet future water supply and wastewater treatment needs are key to _ protecting and restoring-:aquatic-resource s.in;California.. - (c)-There is a pressing need to address-Water supply reliability issues raised by growing urban areas.(d)-Ed orioini"c axial sis b urbari:;water a ericies has identified urban water conservation as acost-effective Y y g _ approach to addressing water supply.needs. (e)There are many water conservation practices that produce significant energy and other resource savings that should be encouraged as a matter of state policy. (f) Since the 1991 signing of the "Memorandum of Understanding Regarding Urban Water Conservation in California," many urban water and wastewater treatment agencies have gained valuable experience that can be applied to produce significant statewide savings of water, energy, and associated infrastructure costs.This experience indicates a need to regularly revise and update water conservation methodologies and practices. (g)To address these concerns,it is the intent of the Legislature to require that residential and commercial real property built and available for use or occupancy on or before January 1, 1994,be equipped with water-conserving plumbing fixtures. (h)It is further the intent of the Legislature that retail water suppliers are encouraged to provide incentives, financing mechanisms, and funding to assist property owners with these retrofit obligations. 1101.2. Except as provided in Section 1101.7,this article shall apply to residential and commercial real property built and available for use on or before January 1, 1994. 1101.3. For the purposes of this article: (a) "Commercial real property' means any real property that is improved with,or consisting of,a building that is intended for commercial use,including hotels and motels, that is not a single-family residential real property or a multifamily residential real property. (b)"Multifamily residential real property' means any real property that is improved with,or consisting of, a building containing more than one unit that is intended for human habitation, or any mixed residential-commercial buildings or portions thereof that are intended for human habitation.Multifamily residential real property includes residential hotels but does not include hotels and motels that are not residential hotels. (c) "Noncompliant plumbing fixture"means any of the following: (1)Any toilet manufactured to use more than 1.6 gallons of water per flush. (2)Any urinal manufactured to use more than one gallon of water per flush. (3)Any showerhead manufactured to have a flow capacity of more than 2.5 gallons of water per minute. (4)Any interior faucet that emits more than 2.2 gallons of water per minute. (d) "Single-family residential real property"means any real property that is improved with, or consisting of, a building containing not more than one unit that is intended for human habitation. (e)"Water-conserving plumbing fixture" means any fixture that is in compliance with current building standards applicable to a newly constructed real property of the same type. (f) "Sale or transfer" means the sale or transfer of an entire real property estate or the fee interest in that real property estate and does not include the sale or transfer of a partial interest, including a leasehold. 1101.4. (a) On and after January 1, 2014,for all building alterations or improvements to single-family residential real property, as a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department, the permit applicant shall replace all noncompliant plumbing fixtures with water- conserving plumbing fixtures. t (b) On or before January 1,2017,noncompliant plumbing fixtures in any single-family residential real property shall be replaced by the property owner with water-conserving plumbing fixtures. (c)On and after January 1,2017, a seller or transferor of single-family residential real property shall disclose in writing to the prospective purchaser or transferee the requirements of subdivision(b) and whether the real property includes any noncompliant plumbing fixtures. 1101.5. (a) On or before January 1,2019,all noncompliant plumbing fixtures in any multifamily residential real property andin any commercial real property shall be replaced with water-conserving plumbing fixtures. (b)An owner or the owner's agent may enter the owner's property for the purpose of installing,repairing,testing, and maintaining water-conserving plumbing fixtures required by this section, consistent with notice requirements of Section 1954. (c)On and after January 1,2019; the water-conserving plumbing fixtures required by this section shill be operating at the manufacturer's rated water consumption at the time that the tenant takes possession.A tenant shall be responsible for notifying the owner or owner's agent if the tenant becon es aware that a water-conserving = - "lumbin fixture within.his or her unit is not o eratin at the manufacturer's rated water consum tion:= ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. ANATIONALLY—RECOGNIZED TESTING OFFICE DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN Copy EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE T GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY ��1 V�,+ : HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL , 'iT DEPARTMENT MAY 18 2015 Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). COP 1�,1 Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER BUIL:... ;jPERTINO kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR i D kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC 'This set of pia*- 'UST be kept at the LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). job site d:r.r, lawful to make ar�y MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN changes or ,•1 ne, or to deviate (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY therefrom, .`)e Building Official. NEUT NEUTRAL UL LISTING. The Stam�ir,:' � ' ,`rations SHALL NOT "LAN NECKED BY NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE � J ,vat of the violation OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE be held to pc' PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING of any prcvls !,-Iance or State LY:�ti. POI POINT OF INTERCONNECTION HARDWARE. BY moo, �ZF��1�G �aT� PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE DATE PLAN ING DEPT SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. PERMIT r CUPERTINO S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS • d - PV4 LCULATIONSCUPERTINO LICENSE GENERAL NOTES i � �- PV5 E DIAGRA Cuts ttd hed wilding Deprwrtrnent CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 � C-10 CALIFORNIA BUILDING CODE AND THE 2013 ' CALIFORNIA RESIDENTIAL CODE. REVIEVVED FOR CODE COMPLIANCE 2. ALL ELECTRICAL WORK SHALL COMPLY WITH - THE 2011 S ENATIONAL ELECTRIC CODE A AMENDED E BY •,r 0 DD Reviewed By _jam,,,, s MODULE GROUNDING METHOD: THE 2013 CALIFORNIA ELECTRIC CODE.* � AHJ: Cupertino _ REV BY DATE COMMENTS REV A NAME DATE COMMENTS a UTILITY: Pacific Gas and Electric Company CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-9505163 00 SCOTT ELLIS RESIDENCE Kyle Wild ELLIS, y. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.,� SolarCit NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10605 FARALLONE DR 5.46 KW PV ARRAY ��� • PART OTHERS OUTSIDESIDE THE RECIPIENT'S MODULES CUPERTINO CA 95014 TMK OWNER:* ORGANIZIZ ATION, EXCEPT IN CONNECTION WITH , THE SALE AND USE OF THE RESPECTIVE (21) REC # REC26OPEZ �: # 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN MVr7tfER PACE NAME: SHEET: REV: DATE: Son Mateo. CA 94402 PERMISSION OF SOLARCITY INC. 408252-9303 PV 1 5 14 2015 T:(650)638-1028 F:(650)638-1029 SOLAREDGE SE5OOOA—US—ZB—U COVER SHEET / / ( )-SOI.-CITY 765-2489)www.solareit.eom PITCH: 21 ARRAY PITCH:21 MP1 AZIMUTH:88 ARRAY AZIMUTH:88 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 21 ARRAY PITCH:21 MP2 AZIMUTH: 178 ARRAY AZIMUTH: 178 Inv O MATERIAL: Comp Shingle STORY: 1 Story PITCH: 18 ARRAY PITCH: 18 El El MP3 AZIMUTH: 178 ARRAY AZIMUTH: 178 MATERIAL: Comp Shingle STORY: 2 Stories r,- �._ MAY 2015 3' FSB REViEIrvEb r`UK C:1JE C©iVIPLIANCE - - - - - - - - - - - - - �w -� Reviewers By J---, �\ MP3 W Moo LEGEND 0 (E) UTILITY METER & WARNING LABEL to lay INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DISCONNECT & WARNING LABELS EH AC DISCONNECT & WARNING LABELS WI 0 DC JUNCTION/COMBINER BOX & LABELS � y117 DISTRIBUTION PANEL & LABELS FSB WIfir —�- - S y c I Lc LOAD CENTER & WARNING LABELS vI Wi Front Of House O DEDICATED PV SYSTEM METER I 3' FS Ln Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR cmiT — -- CONDUIT RUN ON INTERIOR LLI FSB GATE/FENCE M17 Q HEAT PRODUCING VENTS ARE RED r=-I B i� 'I INTERIOR EQUIPMENT IS DASHED L-'J TOTAL ARRAY AREA (SF): 381 SITE PLAN N TOTAL ROOF AREA (SF): 2723 Scale: 1/8" = 1' W E TOTAL ARRAY AREA IS a 13.98 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA S CONFIDENTIAL - THE INFORMATION HEREIN JCB NUMBER: J B-9505163 00 PREMISE OWNER: DESCRIPTION: DESIGN: ELLIS, SCOTT `�` CONTAINED SHALL NOT CE USED FOR THE ELLIS RESIDENCE Kyle Wild .,solarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10605 FARALLONE DR 5.46 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: CUPERTINO, CA 95014 3055 ate.Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (21) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV: DATE Son Molteo,T:(650)638-1028 CA 94402 )638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE5000A-US-ZB-U (408) 252-9303 SITE PLAN PV 2 5/14/2015 (888)-SOL-CITY(765-2489)www.sdarcity.com S1 S1 4" 7, 4,—7» (E) LBW 10'—2 Ar 4'-6" SIDE VIEW O F MP3 NTS 1°- (E) LBW C SIDE VIEW OF MP1 NTS A MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 2411 MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48�r 20'� PORTRAIT 48" 20" RAFTER 2x4 @ 24" OC ROOF AZI 178 PITCH 18 STORIES: 2 „ ROOF AZI 88 PITCH 21 ARRAY AZI 178 PITCH 18 RAFTER 2x6 @ 24 OC ARRAY AZI 88 PITCH 21 STORIES: 1 C.J. 2x4 @16” OC Comp Shingle C.J. 2X6 @16" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS S1 LOCATE RAFTER, MARK HOLE I `- } �a.l 'C �IIVQ ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT .�: , "j HOLE. �� E3utlding Dspg�r# ZEP ARRAY SKIRT (6) = j 2 SEAL PILOT HOLE WITH �f~Y (4) O POLYURETHANE SEALANT. MAY 8 2015 ZEP COMP MOUNT C "�pn UOJE COMPLIANCE: ZEP FLASHING C (3) (3) INSERT FLASHING. Reviewed B (E) COMP. SHINGLE (E) LBW yNsrrsy' (1) (4) PLACE MOUNT. (E) ROOF DECKING (2) (5) INSTALL LAG BOLT WITH B SIDE VIEW OF MP2 NTS 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES J(6) NSTALL LEVELING FOOT WITH WITH SEALING WASHER BOLT & WASHERS. MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) LANDSCAPE 72" 24" (E) RAFTER PORTRAIT 48" 20" STAN DOFF ROOF AZI 178 PITCH 21 S i RAFTER 2x6 @ 24" OC STORIES: 1 ARRAYAZI 178 PITCH 21 C.J. 2X6 @16" OC Comp Shingle CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER- JB-9505163 00 PREMISE O"ER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE ELLIS SCOTTELLIS RESIDENCE Kyle wld �\`�• y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10605 FARALLONE DR 5.46 KW PV ARRAY �,�SolarCit . PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES CUPERTINO, CA 95014 F THE SALE AND USE OF THE RESPECTIVE (21) REC # REC260PEZ 3055 Cleorview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER T:(650)638-1028 F:(650)638-1029 SOLAREDGE SE5000A-US-ZB-U (408) 252-9303 STRUCTURAL VIEWS PV 3 5/14/2015 (888)—SOL—CITY(765-2489)www.solorcity.com UPLIFT CALCULATIONS 05.14.2015 Olaf Cit .,Y PV System Structural Version#44.7 Desian Software Project Information &Table Of Contents Risk Category: II PV System Type SolarCity SleekMount— Comp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 180 Rafter S acin 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 373 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Comp Mount T e C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq:7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig.26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof 5g.30.4-2A/BIC-5A/B Mean Roof Height h 25 ft Section 26.2 Effective Wind Area 1 Module A 17-8 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 30.3-1 Topographic Factor Kzt 1.06 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 24.9 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.30.4-2A/6/C-5A/8 Ext.Pressure Coefficient Down GC Down 0.45 Fig.30.4-2A/BJC-5A/B Design Wind Pressure p p=gh GC nation 30.4-1 Wind Pressure UP P(uP) -21.8 psf ;',L ,'. UPE_RTINO Wind Pressure Down down 16.0 psf .,, iirirTg DBP��ttrer>I� Allowable Standoff Spacings .k i X-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" Li t-V-J' ("�j)E C� Standoff Confl uration Landscape Not-Staggered ib1PLIpA1CIL Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf By /7Afs�y/ Net Wind Uplift at Standoff T-actual -222 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 44.3% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Not-Staggered Max Standoff Tributary Area TMb 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -248 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capadty DCR 49.6°/% CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER DESCNPTION: DESIGN: JB-9505163 00 ��� CONTAINED SHALL NOT E USED FOR THE ELLIS, SCOTT ELLIS RESIDENCE Kyle wld . _�„SOIafC�t�/ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•.,; 1 yo NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10605 FARALLONE DR 5.46 KW PV ARRAY }if/ PART OTHERS OUTSIDE THE RECIPIENT'S MODULES CU P E R TI N 0, CA 95014 f "0 3055 Cleorview Way ORGANIZIZ ATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (21) REC # REC260PEZ PAGE NAME SHEET: REM DATE San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE5000A-US-ZB-U (408) 252-9303 UPLIFT CALCULATIONS PV 4 5/14/2015 (888)-SOL-CITY(765-2489) www.solarcity.corn GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N 8 GEC TO N GROUND ROD Panel Number: Inv 1: DC Ungrounded CA # 888104 ( ) # ( ) Meter Number: INV 1 -(1)SOLAREDGE #SE5000A-US-ZB-U LABEL: A -(21)REC # REC260PEZ C-10 AT PANEL WITH IRREVERSIBLE CRIMP 1005142094 Inverter; 50 OW, 240V, 97.574 w/Unifed Disco and ZB, AFCI PV Module; 260W, 234.3W PTC, MC4, 40mm, Black Frame, ZEP Enabled Underground Service Entrance INV 2 Voc: 37.8 Vpmox: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 SolarCity 4 A 1 _ _ 20OA/2P 5 SOLAREDGE Dc+ MP1 MP2: 1x11 SE5000A-US-ZB-U Dc , (E) LOADS F17--\1 ------------ -------- -- EGC ------------------� L1 r--------- 1z DC+ 1 N DC- I 3 2 30' 12 EGCI DC+ A r------------------------------------------------ - GEC ---� DG - c MP3: 1x10 B 1 ------- G ------------------j GND E -- -- ------------ ---F---- --- I 1 I (1)Conduit Kit; 3/4' EMT N I I EGCIGEC - Z Z --- GEC_--� TO 120/240V SINGLE PHASE UTILITY SERVICE I I I I i� "jPERT'NO y 18 'tv;F:uvci; r cjK i_;tJJE (;talylPLlANCE.; Voc* = MAX VOC AT MIN TEMP POTJ (1)SQUARE D y H 10230 PV BACKFEED BREAKER (1)SolorCit 4 STRING JUNCTION BOX Breoker, 33DA�2P, 2 Spaces AC DC - )Ground Rod; 5/8' x 8', Copper \ 2x2 STRINGS, UNFUSED, GROUNDED PV (21)SOLAREDGE#P300-2NA4AZS PowerBox Optimizer, 30OW, H4, DC to DC, ZEP 51 AWG /10, THWN-2, Block I)AWG 810, THWN-2, Black VOC* =500 VDC Isc =15 ADC (2)AwG 810, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC O k (1)AWG 810, THWN-2, Red (1)AWG 810, THWN-2, Red Vmp =350 VDC Imp=7.33 ADC O (1)AWG 810, Solid Bore Copper ECC Vmp =350 VDC Imp=8.07 ADC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=23 AAC (1)AWG /10, THWN-2, Green EGC . . . . . . . . . . . ._ . . . . . . . . . . . ._. . . . . . . . . . . . . . . . . . . . . . . . . . . .70)AWP 88,.THW4-2,.Green. . . EGC/GEC (1)Conduit.Kit; 3/4'.EMT. (1)AWG 810, THWTI-2, Block Voc* 500 VDC Isc =15 ADC (2 AWG 810, PV Wire, 60OV, Block Voc* =500 VDC Isc =15 ADC ®R(1)AWG 810, THWN-2, Red Vmp =350 VDC Imp=8.07 ADC O (1)AWG 810, Solid Bore Copper ECC Vmp =350 VDC Imp=7.33 ADC . . . (1)AWG 810, THWN-2, Green EGC CONFIDENTIAL - THE INFORMATION HEREINJOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: JB-9505163 00 , CONTAINED SHALL NOT E USED FOR THE ELLIS, SCOTT ELLIS RESIDENCE Kyle Wild 'SolarC�ty. BENEFIT OF ANYONE EXCEPT SOIARCITY INC., MOUNTING SYSTEM: �'.,� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10605 FARALLONE DR 5.46 KW PV ARRAY y , ►,� PART IZ OTHERS OUTSIDE THE CONNECTION RECIPIENTS MODULES C U P E R TI N 0, C A 9 5014 Q -- 3055 Gearview Way fA ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (21) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER 408 252-9303 PV 5 5/14/2015 �)-SOL)638-105 F:9) w 638-102 SOLAREDGE SE5000A-US-ZB-U ( ) THREE LINE DIAGRAM (1198)-SOL-CITY WARNING:PHOTOVOLTAIC PO�NER SOURCE Label • - • Label • • Label Location: PV SYSTEM WARNING Per Code: DISCONNECT FOR ••- CRC R331.2UTILITY OPERATION ELECTRIC SHOCK HAZARD 690.35(F) THE DC CONDUCTORS OF THIS Label Location: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC UNGROUNDERGIZEDD ANDINVERTERIS DISCONNECTPer Code: MAY BE ENEUNGROUNDED. . CEC .•1 .14.C.2 Label Location: Per WARNING ..- ELECTRICSHOCK HAZARD Label Location: DO NOT TOUCH TERMINALS 690.17 MAXIMUM POWER- TERMINALS ON BOTH LINE AND POINT CURRENT{Imp)_A Code: LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER _ IN THE OPEN POSITION POINT VOLTAGE(Vmp) VCEC 690.53 MAXIMUM SYSTEM_V VOLTAGE{Voc) SHORT-CIRCUIT q CURRENT(Isc) WARNING Per Code: INVERTER OUTPUT 705.12.D.7 CONNECTION Label Location: DO LURE' WARNING Per THIS OVERCURRENT DEVICE ELECTRICAL SHOCK HAZARD •• DO NOT TOUCH TERMINALSCEC 690.17 TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF • Per ALWAYS PRESENT WHEN INTERCONNECTION ••- SOLAR MODULES ARE WARNING: ELECTRIC SHOCK EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH CEC690.54; 690.17 TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location: i WARNING AND MAIN BREAKER. PV POWER SOURCE • -• ELECTRIC SHOCK HAZARD Code. MAXIMUM AC _ A ��^�• IF A GROUND FAULT IS INDICATED 690.5(C) OPERATING CURRENT ra<�,s MAY 18 2m NORMALLY GROUNDED MAXIMUM AC CONDUCTORS MAY BE OPERATING VOLTAGE _ V UNGROUNDED AND ENERGIZED Reviewed Label • • Label Location: CAUTION '•Code: • _ PHOTOVOLTAIC AC • PHOTOVOLTAIC SYSTEM DISCONNECTCode: CIRCUIT IS BACKFED CEC 690.64.B.4 Conduit CEC 691 :): Combiner :• Distribution Disconnect Interior • • Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC _ q • CAUTION (POI) (LC): Load Center OPERATING CURRENT Per Code: Per ••- Meter(M): Utility MAXIMUM AC 690.54 SECOND SOURCE IS CEC 1 OPERATING VOLTAGE VPHOTOVOLTAIC SYSTEM '• Point of • • 3055 Clearview Way • • • • • San Mateo,CA 94402 • • • • • i • • • • / {aSolarCity ®pSolar Next-Level PV Mounting Technology '�,SoiarCity ®pSolar Next-Level PV Mounting Technology . Zep System Components for composition shingle roofs Up-roof lid t Omand Zep Intedock 1K�y We 0.1-) Zep Compatible PV Module ZeP 0— Roof Attachment Array Skirt COMPA,/ °� Description PV mounting solution for composition shingle roofs COMPp'(�� Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond Comp Mount Interlock Leveling Foot LISTED Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703 I. Specifications Mounting Block to UL 2703 Designed for pitched roofs ETI E Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standardsi PEE ! IIV • Ing Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 ® � DeO� ht .j • Engineered for spans up to 72"and cantilevers up to 24" j Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End C r.AC wiwo • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No,850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, EVi/EL15qdd'�-j'L6 JJE C:t�i�iNL�HAI E ETL listed to UL 467 850-1467 By zepsolar.com zepsolar.com Listed to UL 2703 y RGViP,1N�J f� This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheel Rev 02.pdf Page: 2 of 2 • solar - • • solar " • • SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer _ P300 P3So P400 Module Add-On For North America (for 60.�Il Pv (for 72 PV (for 96-cell PV modules) modules) modules) INPUT P300 / P350 / P400 ..Rated InpuC Powe"t . .. . . .. .. ...........3W00 ....... .........350........ . .... 40 ....... .... . ...AbsoluteMaximum InutVoltage(Vocat iowerittemperature) 48 60 80 Vdo MPPT Operating Range..........................................................5 43.....................S"60...................8.80 Vdc • Maximum Short Circuit Current(Isc) 10 Adc Max mum DC Input Current 12.5 Adc Mai mum Efficiency 99.5 .............................................................................................................................................................................. Weighted Efficiency 98.8 % ..,,.... _...-. ..r,..4..,.,....,.. Overvoltage Category 1 II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) •, Maximum Output Curren[ .....................................15........................................ ...a ..... ............................................................................... Maximum Output Voltage 60 Vdc • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE �s EMC FCC Part15 Class 8,IEC61000-6-2,IEC610D0-6-3 ts.o"_• .................................................................................................................las................L174'............................ ..... Safety IEC62109-1(class II safety),UL3741 .......................................... .............................................................................................................................. ROH5 Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H( 141 x 212 x 40.5/5.55 x 8.34 x 1.59 mm/in Weight(including cables) 9.50./...2..l gf/Ib Input Connector MC4 Am henol T co ...put....nnec............................................................................................................................................................ Output Wire Type/ConnectorDouble Insulated;Amphenol Output Wire Length...........................................................095./.3:0..................I..........1:2 .3:9._........._......... r^/fi Operating Temperature Range -40-.85/-40- 185 'C/'F .............................................................................................................................................................................. Protection Rating / 4 .. inIP65 NEMA ................. .......................................................................................................................................................... Relative Humidity 0-100 % ............................................................................................................................................................................ ^�wc.e sic roar of m.moaw..moew.or�e m•sz oo"«�mp,.�r..Ibwee. PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE INVERTER SINGLE PHASE 208V 480V PV power optimization at the module-level Min imumStringLengtn(PowerOPt;mi=ers) g 10 18 Maximum String Length(Power Optimizers) 25 25 50 Up to 25%more energy ............................................................................................................................................................................ Maxim um Power per String 5250 6000 12750 W Superiorefficiency(99.5%) ..........................................—.... ........................... ...............................................................................,............. Parallel Strings of Different Lengths or Orientations Yes Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading "................................. ..................'........................................................... ....' Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety i PERTI 11 USA GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us I kill g DeoatMm 15 �EVIEVVEG r-UR CODE (A)IMPL''I`AN E Reuiewea By =@@Single Phase Inverters for North America solar SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-USsolar SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US I SE380OA-US I SE5000A-US SE6000A-US SE760OA-US SE10000A-US SE1140OA-US OUTPUT 9980 @ 208V SolarEdge Single Phase Inverters Nominal AC Power Output 3000 3800 5000 6000 7600 10000@240V 11400 VA Max AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA For North America 545°@24OV1095°.@24OV .....I........ AC Output Voltage Min.-Nom.-Max.* J r 08 SE3000A-US/ SE380OA-US/ SE5000A-US/ SE6000A-US/ 183-2 -229 Vac .... . . .... ..................... ................ ............... ................. ................ ................ .............. . . .................. ........... AC Output. 08Volt. .age.Min.-Nom.-Max." ! � �. � � � � SE760OA-US/ SE10000A-US/ SE1140OA-US 211-240-264 Vac AC Frequency Min:Nom.-Max.• 59.3-60-60.5(with HI country setting 57-60-60.5) Hz ..... .. .. ........... .. 24 @ 208V48 @ 208V Max.Continuous Out u Current 12.5 16 25 32 47.5 A ..... .... ... P. .. ................ .. ..21 @.240V ...... ....... ... ...42 @ 240V... .................. ........... GFDI 1A •r Utility Monitoring,Islanding Protection,Country Configurable Yes �.v erte,` Thresholds 25 INPUT 1 Recommended Max.DC Power*" Warta (STC) 3750 4750 6250 7500 9500 12400 14250 W . .... ............ .. .. . ....... .. .... .. ....... ...... .... .. .................. ................ T,ansforme r-less,Ungrounded Yes Max.Input voltage 500 Vdc _* .. .... . . ...................... ... Nom.....DC Input. .V.oltage 3.2.5 @.20.8V./350@240V Vdc 16.5 @ 208V Max.Input Current"" 9.5 13 18 23 34.5 Adc ^•w ", ;.. _ �:` .........P............................... ..................................15;5 240V 30.5 @ 240V .. ............. ......... M Max Input Short Circuit Current 30 45 Adc .. .... .. ... .... .. .... . .. .... . ... .. .. ... .... .... ... ... ... I Reverse Polarity Protection Yes ...... ... .. . .. .. .. .. ... .. .... .... .... .... ..... .... .... .... ... Ground-Fault Isolation Detection 600kvSensitivity .........................................I ................................ ... ...... .. ...... .. ...... :.. Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 ..%_. 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 % „_ 98 @ 240V .... 97 5 @ 240V .. .. .... .... .....I... .......... .... ... ... .... .. .... I Nighttime Power Consumption 5 2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) .......P............................................................... ........... Revenue Grade Data,ANSI 012,1 Optional STANDARD COMPLIANCE Safety...,., .......................................U L1741,UL1699B,U L3998,CSA 22.2 ............................ ........................................................................... ........... Grid Connection StandardsIEEE1547 ......................................I... .......................................................................................................................... ........... Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG DC Input conduit size/9 of strings/ AWG range 3/4"minimum/1-2 strings/24-6 AWG 3/4 minimum/1-2 strings/14-6 AWG Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x'7.5'/ in/ 30.Sx12.5x10.5/775x315x260 ! Switch(HxWxD) 775 x 315 x 172 775 x 315 x 191 mm ---- - Weight with AC/DC Safety Switch 51.2/23.2 54.7/24.7 ,$-$ 4/.AQ,]� Ib/kg .. . �` Cooling Natural Convection Fanls(user e�lac ble) � p�R INO The best choice for SolarEd a enabled systems Noise <25 a , d T gMin Max 0peratin gTemperature ��'��' y Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance ..Ran&e 13 to+140/-25 to+60(CAN version'"" 4o to © artrlte►�t & ... . . .. . Protection Rating NEMA 3R ppy� •- Superior efficiency(98%) .... ......... ... .. ..... ... 'tuF .. .... N /• 'For other reg oval settings please contact SolarEdge support. P� 7,r Small,lightweight and easy to install on provided bracket Limited to 125v for locarionswhere the yearly average high lemperaturels abo,e 7F/2`C and to 135%for locations where it is below n•F/zs•C. For detailed Information,refer to hao�//www solaredee.us/files/odfsrimerter do oyerslHnit guide Ddf Built-in module-level monitoring ..•A higher current source may be used;thenwerter will limit its input current to the values stated. "?k1/I I � r -'CAN P/Ns are eligible for the Dnran FIT and micmFIT(mlcrcFlTexc.SE11400A-US-CAN). UK L U✓r 'y Internet connection through Ethemnet or Wireless •' IdLIAAI(',� Outdoor and indoor installation k@Vtewea ey - Fixed voltage inverter,DC/AC conversion only - Pre-assembled AC/DC Safety Switch for faster installation - Optional-revenue grade data,ANSI C12.1 t'.r►�l=unsaEc RoHS USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us Q SolarEdge TeChnolooes,Inc.AM nPLs reserved.SOLAREDGE. OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of • ..F r: •: REC PEAK ENERGY ZUNK SERIES 65.55 t0.1 _ 1.38 39.02 _ • SO YEAR PR ' YEAR LINEAR PO REC PE ��� .� _-T -_472n OUTPUT WARRANTY- . o _ US ORT OUTY FR F E ER- 11 _ 1 . Nom inalOperating Coll Temperature!NOCT) 45.7°C(;2°C) 1 Temperature Coefficient ofP,1i -0.40%/°C --- - --- ---- -- i Temperature Coefficient of V1, -0.27%J°C .; 1� Temperature Coefficient oflsc 0.024%/'C REC Peak Energy Z-Link- s"SO` All measurements in inches panels are the perfect choice for building A'... .. t' t Solar Systems that Combl(le long-'lcjsLmg A„. NominalPower-P,v(Wp) 260 ell Type: 60 REC PEmulli-crystalline G diodes product quality with reliable poweroutpu,` Wattcla5ssorting-(Wp) ./-5 3stringsof20cells with bypass to es 4 Nominal 30.7 lass: 0.125 in solar glass with anti-reflection ' REC combines high quality design and. surface treatment manufacturing standards to produce h'ig Nominal PowerCurrent-I.(A) 8.50 Back Sheet: Double layer highly resistant polyester ' Open Circuit Voltage-Voc(V) 37.8 i : ;.� Frame: Anodized alummum black Pperformance solar panels with. P � :' Short Circuli Current-Ix(A) 9.01 ZepGhoovecompatible, uncompromising quality. Panel Efficiency(%) 15.8 Junction Box: IP67rated 0.156 in(12 AWG)solar cable,2 x47.24 in, Thee ectirtcal characteristics are within•/-10%of the indicated values cf Inc,Va and P�,,,at standard Test conditions(STC). Valuesat standard test conditions STC(airmass AMl5,irradiance1000 W%`m°,cell temperature 77'F(25-C)) Connectors: H4Amphenol - Ci 014 At low Irradiance of 200 W/m'(AM 1.5&cell temperature 770F(25'CI)at least 97%of the STC panel efficiency will be achieved. Origin: Madein Singapore vNominal Power-P (Wp) 197 Operational Temperature: -40...+185"F(-40...+85°c) AVOW"., Nominal Power Voltage-V�v VM 29.0 Maximum System Voltage: 1000VUL NominalPowerCurrent-I.(A) 6.81 Design Load: 501bs/ft2(2400Pa)long side MOREPOWER COMPATIBLE WITH PER FT2 ZEP GROOVE FRAME Open Circuit Voltage-Va(V) 35.7 3016sJfta(1436 Pa)A10 t side' - Short Circuit Current-Ix(A) 7.24 -.Max Series Fuse Rating: 15A Nominal operating cell temperature NOCT(800 W/m',AM1.5,wlndspeed I m/s,ambient temperature 68'F(20'C). Max Reverse Ouiient.; 15A',+ O 10 year product warranty. Dimensions: 65 SS x 39 02 x 1.57 in(1665 x 991 x40 mm) USIMPORTEASY TO c @us 25yearlinear power output warranty Area: 17.751`1:20.65m2)USTE4 DUTYFREE INSTALL•: 0 (max.degression in performance of 0.7%p.a.). Weight: 43lbs(195kg) UL 1703.Fire rating:Type 1,Class C q r Note! Ali given specifications are subject to change z without notice at any time. `s REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustaina Ing r products,services and investments for the solar industry. Together with our partners,we create value by providing- tter1 1� meet the world's growing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(tickeO. S 600 tj employees worldwide generated revenues of USD 647 million in 2013. " Zlilfi!(� pQD�PbT►� T t www.recgroup.com ( , - MAY 18 2015 '�kVlkVirkV rUh 1::1JE i:UivINLIAFVC kevi�t,v�l g � r .�