B-2017-1202CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-1202 11525 UPLAND WAY CUPERTINO, CA 95014-5156 (366 38 023) CONVECTEK SUNNYVALE, CA 94085 I OWNER'S NAME: CARMICHAEL PAUL D AND JUDITH B TRUSTEE I I DATE ISSUED: 07/24/2017 I OWNER'S PHONE: 408-252-7927 I (PHONE NO: (408) 687-5754 LICENSFD CONTRACTOR'S DECLARATION License Class C-20 Lic. #253068 Contractor CONVECTEK Date 10/31/2018 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: i., J have and will maintain a certificate of consent to self -insure for Worker's Compensation; as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by \ Section 3700 of the Labor Code, for the performance of the work for which this \, permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information i§'correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against!liabilities,.judgment% costs, and expenses which may accrue, against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulg ions per the Cupertino Municipal Code, Section 9.18. Date 7/24/2017 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two 'reasons: 1. I, as owner of the property, or my employees with wages as their sole I ;compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) z.l 'L -as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). r I hereby affirm under penalty of perjury one of the following three declarations: 1.! I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2.: I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code. Section 9.18. Signature Date 7/24/2017 BUILDING PERMIT INFO: X BLDG —ELECT —PLUMB X MECH X RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: REPLACE FURNACE (SAME LOCATION- CLOSET); REPLACE A/C ( SAME LOCATION- SIDE -YARD) Sq. Ft Floor Area: I Valuation: $5500.00 APN Number: Occupancy Type: 36638 023 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Jasmine Archbold Date: 07/24/2017 RF -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: ALL ROOF COVERINGS TO BE CLASS, "A" OR HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements underChapter6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain complia ce with the Cupertino Municipal Code, Chapter 9.12 and the Heal,"Safety Code, Sections 25505, 25533, and 25534. Owner orized agent: Date: CONSTRUCTION LENDING AGENCY hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION understand my plans shall be used as public records. Licensed GENERAL PERMIT APPLICATIONM EMIMM P COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUPERTINO (408) 777-3228 • FAX (408) 777-3333 • buildingC)cupertino.or-g MISC —7 ❑ PLUMBING F&O l L V [ ZoZ NvIECHANICAL ❑ELECTRICAL ❑MISCELLANEOUS PROJECT ADDRESS ) (_ APN # OWNER NAME D e' PHOIQE E-MAIL STREET ADDRESS CITY, STATE, ZIP , 2 14, LL4 FAX CONTACT NAME PHONE E-MAIL (J J �```(( STREET ADDRESS CITY, STATE, ZIP FAX ❑ OwNER ❑ OWNER-Bua.DER ❑ o-ANER AGENT jk CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAMEC'oA7 v2 c LICENSE NUMBER . ka LICENSE TYPE 26 BUS. LIC # COMPANY NAME C T E-MAIL FAX STREET ADDRESS Z2r.6(3=/ f e CITY, STATE, ZIP PHONE ARCHITECTJENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or DUPLEX • ❑ MULTI -FAMILY BUILDING: ❑ COMMERCIAL PROJECT IN WILDLAND ❑ YES URBAN INTERFACE AREA ❑ NO PROJECT IN ❑ YES FLOOD ZONE ❑ NO IS THE BLDG AN ❑ YES EICHLER HOME? ❑ NO DESCRIPTION OF WORK r C � �c.1✓" Lr � C � �. 1 � G �' �GC� � t TOTAL VALUATION: �® RECEIVED BY By my signature below, I certify to each of the following: T am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to bty ing construction. I authorize representatives of Cupertino to enter the above -i ntified pr perty for inspection purposes. Signature of Applicant/Agent: � �� Date: 0s SUPPLEMENTAL INFORMATION REQUIRED oFFicE usE ovxLY W ❑ OVER THE COUNTER r. D EXPRESS v ❑ STAN&RD ., U. ' ❑ LARGE ,. ❑ ALAJOR r '. AIEPA&c.4pp_2011.doc revised 06/21/11 a 1 n i= yr I,AU r V RIN 11 ALTERATIONS - HVAC 01, CEC-CF1 R -ALT -03-E (Revised 01/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-03-E Alterations - HVAC CZ 1, 3 to 7 and 16 (Page 1 of 1) Site Address: Enforcement Agency: Date Prepared: Permit#: Equipment Type Equipment Efficiency New: Ducting or Lineset Required R -value Conditioned z Floor Area (ft ) Thermostat ❑ Packaged System 2rEvaporator Coil .90 AFUE C6P ❑ R-6 (CZ 1-10,12&13) Ducts Served by system ❑ Setback 'Split System (Condensing Unit SEER 11R-8' (CZ 11,14-16) Ducts i 2 . • ft2 " ' (If not already � HSPF 112: R-2.8 Lineset' present, must Furnace Lineset 13E EER be installed) HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site. 91. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: (Can include new ducting) All Equipment, CF1R-ALT-02-E Condenser Unit, Evaporator Coil, - ,,MCH -20-H Air Handler/Furnace CF3R: MCH -20-H Installer Requirement: Duct leakage (< 15% or, 1510% to outside, or seal all accessible leaks) Exempted from duct leakage testing if: 0 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building 112. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and AII'New Ducts' CF1R-ALT-02-E CF2R-MCH-01-E, MCH -20-H, MCH -22-H, MCH -(23 or 24)-H ' CF3R-MCH-20-H, MCH -22-H, MCH -(23 or 24) -HZ Installer Requirement: Duct leakage < 5%, Fan Efficacy (0.58W/CFM), Air Flow >_ 350 CFM/ton (or Standards Table 150.0-13 / C alternative) ❑ 3. All New. Ducts with Replacement Required Compliance Documentsto be left on site for Final: Includes replacing or, installing All New CF1R-ALT-02-E Ducts',and one or more of the;following: CF2R-MCH-01-E, MCH -20-H, MCH -(23 or 24)-H Condenser Unit, Evaporator: Coil, Furnace CF3R-MCH-20-H, MCH -(23 or 24)-H Installer Requirement: Duct leakage < 5%, Air Fiow>_ 350 CFM/ton (or Standards Table 150.0-B / C alternative) ❑ Exempted from du;ct'leakage testing if existing duct systems are constructed, insulated or sealed with asbestos. ❑ 4. New Ducting over 40 feet, Required Compliance Documents to be left on site for Final: Adding or re.placing!ducts in unconditioned CF.1R-ALT-02-E space but less than All New Ducts' CF2R-MCH-20-H CF3R-MCH-20-H Installer Required to: Duct leakage (< 15% or, < 10% to outside, or seal all accessible leaks) ❑ Exempted from ductleakage testing if existing duct systems are constructed, insulated or sealed with asbestos. ' All new ducting requires R-8 insulationwhen more than 40 ft installed in CZs 11 & 14-16 and R-6 in CZs 1-10, 12 & 13, and R-6 insulation when less than 40 ft installed. This includes in walls, between floors etc. Z A New Duct system is when the duct system is constructed of at least 75 %new duct material, and up to 25%may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, plenums, duct material. ' R-2.8 (1" thick insulation) for linesets 1" and less. Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the followingunder'perialty of perjury, under the laws of the State of California: 1. The information provided on -this Certificate of Compliance is true and correct. 2. 1 am eligible under 'Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy' features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of'Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR. 5. The building des igin features or system design features identified on this Certificate of Compliance are consistent with the information provided on other: compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. ResponsibJW Designer Na e: Responsible Designer Si nature:Date Signed License://��� Comp�G . � �� /I �2 re1_005; 2t4City/State/Zip v PtP— Q 7 For assistance or questions regarding the Energy Standards, contact the Energy Hotlipe fix: 1-800-772-3300