Loading...
B-2017-1237CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-1237 10415 CHERRY TREE LN CUPERTINO, CA 95014-2005 (316 33 050) HIGHLIGHT SOLAR INC A CALIFORNIA CORPORATION SAN JOSE, CA 95117 OWNER'S NAME: DANAI BEHNAM AND AMENEH TRUSTEE DATE ISSUED: 07/28/2017 OWNER'S PHONE: 408-725-2616 PHONE NO: (408) 489-9273 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C46 Lic. #960376 Contractor HIGHLIGHT SOLAR INC A CALIFORNIA CORPORATION Date X BLDG _ELECT —PLUMB — MECH X RESIDENTIAL — COMMERCIAL 04/30/2019 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my JOB DESCRIPTION: license is in full force and effect. (N) 8-PANEL ROOF MOUNTED PV SYSTEM (2.64 kW) I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the _performance of the work for which this permit is issued. �' i. have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $10000.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances 316 33 050 and state laws, relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the PERMIT EXPIRES IF WORK IS NOT STARTED City of Cupertino against liabilities, judgments, costs, and expenses which WITHIN 180 DAYS OF PERMIT ISSUANCE OR may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands+and'will comply with all non-point 180 DAYS FROM LAST CALLED INSPECTION. source regulatio s per the Cupertino Municipal Code, Section 9.18. Issued by: Jasmine Archbold Si ure Date 7/28/2017 Date: 07/28/2017 - RE-ROOFS: I hereby affirm that am exempt from the Contractor's License Law for one of the All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: installed without first obtaining an inspection, I agree to remove all new materials for 1. I, as .owner of the property, or my employees with wages as their sole inspection. compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) Signature ofApplicant: z. I, as owner oft he property; am exclusively contracting with licensed Date: 7/28/2017 contractors to 'construct the project (Sec.7044, Business & Professions Code). ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER Thereby affirm ander penalty of perjury one of the following three declarations: t. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation; as provided for by Section 3700 of the Labor Code, for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the z. I have and will maintain Worker's Compensation Insurance, as provided for by California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Section 3700 of the Labor Code, for the performance of the work for which this permit-is issued. Health & Safety Code, Section 25532(a) should I store or handle' hazardous s. I certify that in the performance of the work for which this permit is issued, I material. Additionally, should I use equipment or devices which emit hazardous. air contaminants as defined by the Bay Area Air Quality Management District I shall not employ any person in any manner so as to become subject to the will maintain compliance with the pertino!Municipal Code, Chapter 9.12 and Worker's Compensation laws of California. If, after making this certificate of the Health & Safety Cod , ections�25505, 25533, and 25534. exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I' must forthwith comply with such provisions or this permit shall Owner or_ rued agent: be deemed revoked. Date' . 2 7 APPLICANT CERTIFICATION CONSTRUCTIO'NLENDING AGENCY I hereby affirm that there is a construction lending, agency for the performance I certify that I have read this application and state that the above information is of work's for which this permit is issued (Sec. 3097, Civ C.) correct. I agree-to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this'permit. Additionally, the applicant understands ARCHITECT'S DECLARATION and will comply with all'non-point source regulations per the Cupertino Municipal I understand my plans shall be used as public records. Code, Section 9.18. Licensed Professional Signature Date 7/28/2017 CU PERT I ISI O ALTERNATIVE ENERGY PERMIT APPLICATION COM MUNITY.DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingCcDcupertino.org PROJECT ADDRESS / re 6 O�VNERNAME ` e�' i�'\ ✓�Q-� PHONE y� ✓ ICl Zoo 2, STREET ADDRESS ZI FAX CONTACT NAME rD. ^ PHONE { STREET ADDRESS 5M �` �� CITY, STATE,` ZIP ,� n _ FAX V ElOWNER. EJOWNER-BUILDER ❑ ONTTERAGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑OENGII.'EER ❑ DEVELOPER ❑ TENANT- CON*fRACTORNAME KVCLJ�LICENSE NUMBER C1601 LICENSE BUS LICLfA COMPANY NAME E -MAI FAX STREET ADDRESS f - 1 i "� CITY, STA PHONE L % g V1D q 233 ARCHITECT/ENGINEER NAMES LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD Or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROTECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PAWELS. NUMBER OF PANELS/UNITS: 1 KILOWATTS (COMMERCIAL ONLY): r / ' m TOTAL VALUATION:` © OL O DESCRTPTION OF WORK �� 4 (0'� By my signature below, I certify to each o the following: I am the property owner or authorized agent to act on the property owne`r's behalf. I have read this application and'the information I have pr ided is correct. I have read the Description of Work and verify it is accurate. I agree,;to comply with all applicable local ordinances and;state laws relating� to bui g construction. I authorize representatives of Cupertino to enter the above -id f ntiifiedd p opertty for inspection purposes. Signature of Applicant/Agent- .' Date: !� p'' / ' T SUPPMET IIF ATI N REQUIRED 'tom 3` T rT„a.Sa cY Y.i M ;'3xFFi " � '- E r ❑ OVER THE-CQLil��'ER'�r sx �:"- E a i ❑E7�PRESS k. ✓ s k U � r..r.a ria NMI" K r 3 . ;n I11�JQR ,a PVApp_2011.doc revised 03/16111 M SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ice`' 1 I 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUPERT'INO (408) 777-3228 •FAX (408) 777-3333 • building(d)-cupertino.org PERMS CANNUT:BE FIIITA LIJD UNTIL THIS CEBTIF.CATEiAS BEEN C(3MPLE" PURPOSE - This affidavit is a.self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314,2016 CBC Sections 420 6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000 00, CRC Section 8314 and CBC Sections 907.2.11.5 and 420 6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of X X the bedroom(s) On every level of a dwelling unit includingbasements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420 6 and shall be approved by the Office of the State Fire Marshal. Power Supply In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.114 and 420 6.2. An electrical permit is required for alarms which must be connected to the building wiring As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below Permit _ Address- I �1 C �`�� t Y-kPermit 1lTo Specify Number of Alarms: Carbon _t_..... _...i I have read and agree to comply with the terms ana ns conujvuvi uus 51cav eiR Owner (or Owner Agent's) Name. Date: Signature .. �. „contractor Name Signat r Lic.# ... Smoke and COfoi-imdoc revised 12/15116 CUPERTINf,3 Owner Name f WATER -CONSERVING PLUMBING FIXTURES .OWNER CERTIFICATE OF COMPLIA14CE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 0 `FAX (408) 777-3333 • building(a.cupertino.orq Address I C,"? 1. - Is your real property a registered historical site? r. ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? N Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. - ❑ No Go to Question 3. s 3, Is water service permanently disconnected for your building? Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of`form. CE No Go to Question 4. 4. Is your real property built' and available for use or occupancy on or before January 1, 1994? No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.. G Yes My real properly is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101,8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: My properly is a single family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or unprovements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a ntiultifainily residential real property.' See Civil Code Section 1101.5. On and after January ll, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a convnerciaZ real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving pluimbing fixtures in accordance with Civil Code Sections 1101.!1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following page.I I ---I Owner or Owner Agent's Signa �.� �I Date: e 1 LJnon comDletin2 and signing this Certificate, pse return it to the Building Division in order to final your building pennit. SB407 2015. doe revised 01105117 ROOF PLAN SINGLE LINE DIAGRAM RACKING DATA SHEET ATTACHMENT LAYOUT CODE REQUIRED SIGNAGE INVERTER DATA SHEET VICINITY MAP SCALE: NTS SATELLITE VIEW SCALE: NTS PHOTOVOLTAIC SYSTEM SUMMARY SYSTEM SIZE: DC STC: 2.64 KW SYSTEM SIZE: AC CEC: 2.42 KW SOLAR MODULES: (8) PANASONIC VBHN330SA16 MICROINVERTERS:(8) ENPHASE IQ6-60-2-US MOUNTING SYSTEM: IRONRIDGE ROOF MOUNT ELECTRICAL INFORMATION: EXISTING MAIN SERVICE PANEL BUS SIZE: 200A MAIN SERVICE BREAKER SIZE: 200A BUILDING INFORMATION: ONE STORY HOUSE CONSTRUCTION TYPE: V-B OCCUPANCY: R ROOF: COMPOSITION SHINGLE TRUSSES 2"X4" @ 24" O.C. Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 Class C-46 INSTALLER DESIGNER NAME: NAREK A. DATE: 26 JULY 2017 1 SHEET INDEX 2 3 4 5 6 7 8 9 10 11 MODULE DATA SHEET MODULE & RACK CERTIFICATION RACKING SPECS ATTACHMENT DATA SHEET PROJECT NAME: Behnam Danai ADDRESS: 10415 Cherry Tree Lane Cupertino, CA, 95014 STREET VIEW SCALE: NTS THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL BE IN ACCORDANCE WITH THE MOST RECENT CPC, CMC, 2016 CEC, 2016 CRC, 2016 CBC AND 2016 NEC. AS AMMENDED BY THE LOCAL AHJ. STRUCTUAL CONNECTIONS SHALL BE TO 2016 IBC. SITE PLAN GENERAL NOTES 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RE C O G N I ZE D E LEC T RIC AL TE S T I NG LAB ORATO RY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, U T I L I T Y C O . A N D C I T Y I N S P E C T O R S A S N E E D E D . 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS VOER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS C A P A B L E O F W H I T S A N D I N G T H E E X T R A W E I G H T . 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS WI LL B E RE D - LI N E D AN D U P D AT E D AS AP P RP RI AT E . 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK PHOTOVOLTAIC NOTES: 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8. INVERTER IS EQUIPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12. ALL WORK SHALL BE IN ACCORD WITH THE 2016 CBC, 2016 CEC AND 2016 NEC WITH SPECIAL EMPHASIS ON ARTICLE 69 13. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(C) AND SIZED AS PER SEC 250.166 15. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-166. 16. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS Jasmine Archbold 07/31/17 07/31/17 B-2017-1237 Jasmine Archbold 1 ROOF PLAN CONTRACTOR N 0° S 180° E 90° W 270° SCALE 0 1 5 10 ft X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. PHOTOVOLTAIC ARRAY (8) Panasonic 330W Modules (VBHN330SA16) (8) Enphase Energy Microinverters ( IQ6-60-2-US) EMT type Conduit MSP (E) 200A Main Service Panel Solar Module J/B (N) Nema 3R Junction Box UNIT INDEX FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO MAIN SERVICE PANEL MATERIAL LIST TABLE Module : x 8 Panasonic VBHN330SA16 Microinverter : x 8 Enphase IQ6-60-2-US Rail : x 6 168" Iron Ridge XR10 Rails Attachment : x 23 Eco Fasten GF1 Ground Lug :x 5 Ironridge UFO Ground Lugs End Clamp :x 9 Ironridge UFO End Clamps Mid Clamp :x 12 Ironridge UFO Mid Clamps Channel Strut: x 8 Enphase Trunk Cable : x 8 Monitoring Gateway: x 1 Microinverter Note: This installation will provide verification at time of inspection that 2016 CRC sections 314/315 (smoke and CO detectors) are in compliance. 1.UFO GROUNDING MID CLUMP 2.UFO END CLAMP 3.IRONRIDGE RAIL 4.UFO GROUND LUG 5.ONE LUG BETWEEN TWO SPLICES OF RAILS 6.ONE LUG AT THE END OF THE RAIL TO GO TO THE J-BOX 7. #6 BARE COPPER EGC 8.PV MODULES GROUNDING AND CLAMPING DETAIL UL 2703 AND UL467 CERTIFIED 1 2 4 5 7 8 3' fire setback 3' fire setback1 8'' fire setback 18'' fire setbackMSP Cherry Tree LaneSolar PV Array 8 Panasonic 330W Modules 8 Enphase IQ6 Microinverters Pitch: 18 Deg Orientation: 180 Deg J/B Gate Gate Jasmine Archbold 07/31/17 All the photovoltaic systems wires that on the roof and side of the building shall be protected against physical damage 2 SINGLE LINE DIAGRAM CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. PV ARRAY INFORMATION PV MODULE RATINGS # STC INVERTER RATING EXISTING SPLIT PHASE: 3W, 120/240V BUSBAR RATING = 200A MAIN SERVICE BREAKER = 200A END FEED 120% RULE: MAX ALLOWED FEED: 240A PV BACKFEED BREAKER SIZE: 15A ACTUAL FEED: 200A "MSP" + 15A "SOLAR" =215A <= 240A MAX MAIN PANEL RATING 8 PANASONIC 330WATT SOLAR MODULES MODEL # VBHN330SA16 8 ENPHASE IQ6 MICROINVERTERS MODEL # IQ6-60-2-US NUMBER OF BRANCH CIRCUITS : 1 NUMBER OF MODULES PER BRANCH CIRCUIT: 8 MAX WATTS STC: 8 * 330W = 2,640W [ AC.1 ] FROM PV MODULES TO J-BOX (3) ENPHASE TRUNK CABLE #12 AWG, PV WIRE + (1) #6 AWG BARE CU EGC FREE IN THE AIR [ AC.2 ] FROM J-BOX TO MAIN SERVICE PANEL (3)#10 AWG THWN-2 + (1) #8 AWG CU EGC, 3/4" EMT TYPE CONDUIT #OF MICROINVERTERS IN BRANCH CIRCUIT : 8 EACH INVERTER OUTPUT MAX CURRENT: 0.96 A BRANCH CIRCUIT CURRENT: 8 * 0.96 *1.25 = 9.6 A BREAKER SIZE PER B. CRCT - 15A MAXIMUM CONTINUOUS CURRENT: 9.6A RACEWAY DISTANCE FROM THE ROOF 1 1 2'' (TEMP - 39 + 22 = 61C) TEMP. DERATE FACTOR - 9.6 A / 0.58 = 16.6 A WIRE SIZE FROM NEC TABLE 310.15(b)16 - 10 AWG AMBIENT TEM FACTOR 0.58 PER NEC 310.15(b)(2)(a) PV SYSTEM MAX DC OUTPUT: 8 * 330W = 2,640W PV SYSTEM MAX AC OUTPUT: (8) PANASONIC VBHN330SA16 (8) ENPHASE ENERGY IQ6-60-2-US Pmax (PTC Rating) PER MODULE: 311.3W 311.3W * 8 = 2.49 KW 2.49 KW * 97.0% CEC INVERTER = 2.42KW OUTPUT CALCULATIONS J BOX NEMA 3R 6" BY 6" MAIN METER UTILITY EXISTING 200A MAIN SERVICE PANEL 120/240V 1-PHASE,3-WIRE #6 AWG EGC COPPER WIRE EXISTING GROUND ROD RAIL GROUNDING MID CLAMP GROUNDING LUG 3/4" EMT CONDUIT 40 FEET [AC.2] INSTALL 2P 15A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 200A BUS200A END FEED MAIN C/B PV system is rapid shutdown ready by CEC 690.12 Grounding specs:Ironridge has a UL1703 Listed integrated grounding. No additional ground lugs and copper wire are needed (See integrated grounding spec sheet on page #12) PEAK PWR TRACKING VOLTAGE = 27-37 V CEC EFFICIENCY = 97.0 % ENCLOSURE : NEMA 6 MAXIMUM INPUT CURRENT = 15 A MAXIMUM OUTPUT CURRENT = 0.96 A MAXIMUM INPUT POWER = 195 - 330W MAXIMUM OUTPUT POWER = 240 W [AC.1] PV ARRAY 8 PANASONIC 330W MODULES, 8 ENPHASE IQ6 MICROINVERTERS SHORT CIRCUIT CURRENT I-SC = 6.07A MAXIMUM POWER CURRENT I-MP = 5.70A OPEN CIRCUIT VOLTAGE V-OC = 69.7V MAXIMUM POWER VOLTAGE V-MP = 58.0V Jasmine Archbold 07/31/17 N 0° S 180° E 90° W 270° CAUTION Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. 1 2 (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) 3 4 WARNING! ELECTRIC SHOCK HAZARD. DO NOT TOUCH THE TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. 5 (TO BE LOCATED ON SUB-PANEL ONLY WHEN SUB-PANEL IS DEDICATED FOR PV ONLY) 6 7 8 THIS PANEL FED BY MULTIPLE SOURCES (UTILITY & SOLAR) 9 SOLAR (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE10 (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) PV ARRAY J BOX INVERTER INTEGRATED DC DISCONNECT PV SUB-PANEL * if applicable SUB-PANEL * if applicable AC DISCONNECT * if applicable METER MAIN SERVICE PANEL 2 1 3 4 5 6 7 9 8 10 7 9 8 10 7 7 9 8 10 MARKINGS, LABELS AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects.CFC 605.11.1 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering. CFC 605.11.1.1 3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE. CFC 605.11.1.2 4.Marcking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated CFC 605.11.1.3 *if applicable POWER TO THIS BUILDING IS ALSO SUPPLIED FROMTHE FOLLOWING SOURCES WITH PV EQUIPMENT LOCATED AS SHOWN: PV SUB-PANEL ONLYCAUTION AUTHORIZED SOLAR PERSONNAL ONLY! CAUTION SOLAR DC CURRENT PRESENT DURING DAYLIGHT HOURS AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT: 7.7 A MAX NOMINAL AC OPERATING VOLTAGE: 240 Vac WARNING! ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. 11 (STICKER LOCATED ON THE PV SUB PANEL) 11 PV LOAD CENTER SIZED FOR PV BREAKERS ONLY OR RENDERED UNABLE TO ACCEPT ANY ADDITIONAL LOADS. 3 CODE REQUIRED SIGNAGE CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. DC DISCONNECT DC PHOTOVOLTAIC POWER SOURCE RATED MAX POWER POINT CURRENT- 5.70 AMPS RATED MAX POWER POINT VOLTAGE- 58.0 VOLTS MAXIMUM SYSTEM VOLTAGE- 81.5 VOLTS SHORT CIRCUIT CURRENT- 6.07 AMPS 12 (STICKER LOCATED ON THE MAIN SERVICE PANEL) PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN 12 Cherry Tree LaneSERVICE POINT & UTILITY METERING SOLAR PV ARRAY WITH MICROINVERTERS ON ROOF Jasmine Archbold 07/31/17 4 SITE PLAN CONTRACTOR N 0° S 180° E 90° W 270° X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. MSP (E) Main Service Panel Solar Module UNIT INDEX Microinverter SCALE 0 5 20 ftPROPERTY LINE 10 MSP Gate Gate Cherry Tree LanePublic SidewalkDriveway 38' 30' 21' 53' 95' 75' Jasmine Archbold 07/31/17 5 ATTACHMENT LAYOUT CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. MODULE WEIGHT (lbs) # OF MODULES TOTAL MODULE WEIGHT (lbs) RACK WEIGHT (lbs) TOTAL SYSTEM WEIGHT (lbs) # OF STANDOFFS MAX SPAN BETWEEN STANDOFFS (in) LOADING PER STANDOFF (lbs) TOTAL AREA (sq.ft.) LOADING (PSF) FLASH MOUNTING DETAIL 40.8 8 326 65 417 23 48 18.1 3.06 136 MICROINVERTERS WEIGHT (lbs)26 EXISTING 2" BY 4" @24" O.C. ROOF TRUSSES IRONRIDGE XR10 RAIL ATTACHMENT 1. Ironridge XR10 Racking System 2. Eco Fasten GF1 Attachment 3. Racking loading calculations were performed for ASCE 7-10 wind speeds @ 110 mph for B and C exposure categories and ASCE 7-10 Seismic Design Category E. 4. Roof attachment hardware to be mounted to existing structure (2"x4"@24" O.C. Trusses) at 48" O.C. rail spans or less. 5. Lag bolts are 5/16" X 3.5" stainless steel with 2.5" minimum embedment into the roof trusses. 6. Roof sheathed with 1/2" plywood and upper surface is faced with felt paper. Finished roof surface is One layer of Composition Shingle. 7. Mounts or/and mounting hardware will be sealed with Tremco Vulkem 116 Polyurethane Sealant or equivalent. ATTACHMENT DETAILS L-FOOT GF-1 FLASHING 5/16" * 3.5" HANGER BOLT MIN. 2.5" EMBED INTO FRAMING MEMBER FRAMING MEMBER SHEATHING EPDM WASHER 5/16" EPDM BONDED 304 18.8 SS WASHER IRONRDIGE XR10 RAIL 6" SOLAR MODULE DF #2 2" BY 4" 24 " O.C. 2"x4" Blocking 2"x4" Purlin 18° 48''24'' Jasmine Archbold 07/31/17 6 INVERTER DATA SHEET CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Jasmine Archbold 07/31/17 7 MODULE DATA SHEET CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Jasmine Archbold 07/31/17 8 MODULE & RACK CERTIFICATION CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Jasmine Archbold 07/31/17 9 RACKING DATA SHEET CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Jasmine Archbold 07/31/17 10 CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. RACKING SPECS Jasmine Archbold 07/31/17 11 CONTRACTOR X JULY 26, 2017 10415 Cherry Tree Lane Cupertino, CA, 95014 Behnam Danai Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. ATTACHMENT DATA SHEET Jasmine Archbold 07/31/17